Project No.

: Calculation Number :
Aker Powergas Pvt. Ltd.
2090/01557 PEIN08-2095-6102-A008-VI
Client : IOCL VADODARA Rev. Prep. By Date Chkd. By Date

Project : RU & MS/HSD QIP (DCU)

Subject :
Sheet of
IN-SITU COLUMN SPLICE DESIGN

C/L COL / PLT


WEB PLT

FLANGE PLT S1 S1 C/L COL / PLTS

C/L SPLICE / PLTS b


d a C/L COL / PLTS

c -50
(TYP) 75
(TYP)

ELEVATION SECTION S1-S1

COLUMN DETAILS
Area of Area of Area of
Flange Flange Web Thk., column, flanges web alone,
Depth, mm width, mm thk., mm mm mm^2 alone, mm^2 mm^2
625 450 36 12 39036 32400 6636

Yield stress of the beam and connection elements = 250 N/mm^2

Axial load to be carried by flange plates = 32400*0.6*250/1000 = 4860 kN


Axial load to be carried by web plates = 6636*0.6*250/1000 = 995.4 kN

FLANGE PLATE DESIGN


Width of the flange plate, a = 450-2*-50 = 550 mm
Thk. of flange plate reqd. = (4860/2)*1e3/(0.6*250*550) = 29.45 mm, say = 32 mm, >= 29.45mm, OK
Check for weld size and length required for flange plate
Alround weld considered for flange plate.
Weld size considered = Enter weld size here---> 16 mm, < 32mm, okay
Effective width factor = 0.7 (Cl 6.2.3.1 of IS 816-1969)
Effective throat thickness = 0.7*16 = 11.2 mm
Allowable strength of shop fillet welds = 1100 kg/cm^2 = 107.9 N/mm^2 (Cl 7.1.2 of IS 816-1969)
Factor for site or shop weld (1.0 for shop and 0.8 for site welds) = 0.8 (Cl 7.2 of IS 816-1969)
Increase factor for Wind / Seismic cases = 1.25 (Cl 7.3 of IS 816-1969)
Permissible strength in fillet weld = 0.8*1.25*107.9 = 107.9 N/mm^2
Width of horizontal portion of weld available, a = 450 mm
Length of vert. weld reqd., b = (4860/2*1e3)/(11.2*107.9)-450 = 1560.8 mm

C940001 R4 382538636.xls
Project No. : Calculation Number :
Aker Powergas Pvt. Ltd.
2090/01557 PEIN08-2095-6102-A008-VI
Client : IOCL VADODARA Rev. Prep. By Date Chkd. By Date

Project : RU & MS/HSD QIP (DCU)

Subject :
Sheet of
IN-SITU COLUMN SPLICE DESIGN

C/L COL / PLT


WEB PLT

FLANGE PLT S1 S1 C/L COL / PLTS

C/L SPLICE / PLTS b


d a C/L COL / PLTS

c 25
(TYP) 90
(TYP)

ELEVATION SECTION S1-S1

COLUMN DETAILS
Area of Area of Area of
Flange Flange Web Thk., column, flanges web alone,
Depth, mm width, mm thk., mm mm mm^2 alone, mm^2 mm^2
625 250 20 12 17020 10000 7020

Yield stress of the beam and connection elements = 250 N/mm^2

Axial load to be carried by flange plates = 10000*0.6*250/1000 = 1500 kN


Axial load to be carried by web plates = 7020*0.6*250/1000 = 1053 kN

FLANGE PLATE DESIGN


Width of the flange plate, a = 250-2*25 = 200 mm
Thk. of flange plate reqd. = (1500/2)*1e3/(0.6*250*200) = 25 mm, say = 25 mm, >= 25mm, OK
Check for weld size and length required for flange plate
Alround weld considered for flange plate.
Weld size considered = Enter weld size here---> 10 mm, < 20mm, okay
Effective width factor = 0.7 (Cl 6.2.3.1 of IS 816-1969)
Effective throat thickness = 0.7*10 = 7 mm
Allowable strength of shop fillet welds = 1100 kg/cm^2 = 107.9 N/mm^2 (Cl 7.1.2 of IS 816-1969)
Factor for site or shop weld (1.0 for shop and 0.8 for site welds) = 0.8 (Cl 7.2 of IS 816-1969)
Increase factor for Wind / Seismic cases = 1.25 (Cl 7.3 of IS 816-1969)
Permissible strength in fillet weld = 0.8*1.25*107.9 = 107.9 N/mm^2
Width of horizontal portion of weld available, a = 200 mm
Length of vert. weld reqd., b = (1500/2*1e3)/(7*107.9)-200 = 793 mm