Vous êtes sur la page 1sur 4

MonGrout GP ‐ 11803 

   Gaseous precision expansive non shrink cementitious Grout 

TECHNICAL DATA SHEET
Description: MonGrout GP , precision grouting is supplied as a ready to use dry powder. The addition of a 
controlled amount of clean water produces a free flowing, non‐shrink grout for gap thicknesses up to 100mm. 
MonGrout GP is a blend of Portland cement, graded fillers and chemical additives which impart controlled 
expansion in the plastic state whilst minimising water demand. The low water demand ensures high early 
strength. The graded fillers are designed to assist uniform mixing and produce a consistent grout 

Typical Applications Product Features

 Turbines  Gaseous expansion system compensates
for shrinkage and settlement in the plastic
 Compressors
state
 Boiler
 No metallic iron content to cause staining
 Feed Pumps
 Pre‐packed material overcomes onsite
 It can also be used for anchoring a wide range batching variations
of fixings.
 Develops high early strength without the
 These include masts, anchor bolts and fence use of chlorides
posts
 High ultimate strength ensure the durability
 Duct grouting. of the hardened grout
 Non‐shrink infilling and jointing.  Free flow ensures high level of contact with
 Grouting tunnel linings. load bearing area

Product Image 
Properties  Standard  Unit  Values 
Base  Chemical additives  modified 
~  ~     
Cementious system 
Color     
ASTM D 1544 
  ~  Grey 
Appearance  ASTM D 1544  ~  Free Flowing Dry Powder 
Fresh Wet Density (approx. depend  2242
ASTM D 1475  Kg/m3
upon the actual consistency used) 
Typical Properties 

Dry Density  ASTM D 1475  Kg/m3  2100 


Pot Life @30°C  IS 101  min  20 
WP Ratio   ~ 0.18  
Compressive  Strength 
@1 Day  24 
BS 1881  N/mm2 
@3 Days  45 
@28 Days  65 
Flexural Strength@7 Days  BS 4551  N/mm2  9 
Young Modulas  ASTM D 496  N/mm2  28 
Adhesive Shear Strength  ASTM D 4541  N/mm2 17 
Hardness  ASTM D 2240  shore D  82 
Chemical Resistance  ASTM C 267  %  Excellent 
Maximum Application Temp  VISUAL  °C  40 
Consumption  Kg/Cum 1900  

Application Instructions

Foundation surface 
 The substrate surface must be free from oil, grease or any loosely adherent material. If the
concrete surface is defective or has laitence, it must be cut back to a sound base. Bolt holes
and fixing pockets must be blown clean of any dirt or debris.

Pre‐soaking 
 Several hours prior to placing, the concrete substrates should be saturated with fresh water.
Immediately before grouting takes place any free water should be removed with particular
Surface Preparation  

care being taken to blow out all bolt holes and pockets.

Base plate 
 It is essential that this is clean and free from oil, grease or scale. Air pressure relief holes
should be provided to allow venting of any isolated high spots.

Levelling shims 
 If these are to be removed after the grout has hardened, they should be treated with a thin
layer of grease.

Formwork 
 The formwork should be constructed to be leak proof. This can be achieved by using foam
rubber strip or mastic sealant beneath the constructed formwork and between joints. In some
cases it is practical to use a sacrificial semi‐dry sand and cement formwork. The formwork
should include outlets for pre‐soaking.
                         
   
           
 For best results a mechanically powered grout mixer should be used. 
 

    When quantities up to 50kg are used, a heavy duty slow speed drill (400‐500 rpm) fitted with 
a paddle is suitable.. 
 
 Larger quantities will require a heavy duty mixer. 
Mixing 

 
 To enable the grouting operation to be carried out continuously, it is essential that sufficient 
  mixing capacity and labour are available.  
   The use of a grout holding tank with provision to gently agitate the grout may be required. 
   Flowable (W/P 0.18)  
   Pourable (W/P 0.165) 
   
   

  Application :  
   At 30 C place the grout within 20 minutes of mixing to gain full benefit of the expansion 
  process. 

   MonGrout GP can be placed in thicknesses up to 100mm in a single pour when used as an 
under plate grout. 
 
 For thicker sections it is necessary to fill out MonGrout GP with well graded silt free aggregate 
 
Application Instructions 

to minimise heat build up. 
   Typically a 10mm aggregate is suitable. 50 ‐ 100% aggregate weight of MonGrout GP can be 
added. 
 
 Any bolt pockets must be grouted prior to grouting between the substrate and the base plate. 
                       
       Continuous grout flow is essential. Sufficient grout must be prepared before starting. The time 
                   
      taken to pour a batch must be regulated to the time to prepare the next one 
                   
                         
       Where large volumes have to be placed MonGrout GP may be pumped. A heavy duty 
                   
      diaphragm pump is recommended for this purpose. Screw feed and piston pumps may also be 
                   
      suitable. 
                   
                         
                         
                         
                         
                         
                         
                         
 

Product Limitation 
 Application should not be undertaken if the temperature is 10°C and falling, nor when the 
      prevailing relative humidity exceeds 90%. 
                   
                         
       Higher temperatures will shorten curing time and conversely, lower temperatures and high 
   
relative humidity will lengthen curing time.  
 
 MonoGrout GP is supplied ready‐to‐use on site. Never add cement or aggregates to 
  MonoGrout GP  
   
 
 
Shelf Life &Storage 

 
 MonoGrout GP has a shelf life of 6 months if kept in a dry store in sealed bags. If stored in high 
  temperature and high humidity locations, the shelf life may be reduced. If stored at high 
  temperatures the shelf life may be reduced. 
 
   
 

 
LIMITED WARRANTY NOTICE
 
Monarch warrants this product to be free from manufacturing defects and to meet the technical properties on the current 
  Technical Data Sheet, if used as directed within shelf life. Satisfactory results depend not only on quality products but also 
upon many factors beyond our control. MONARCH MAKES NO OTHER WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, 
  INCLUDING  WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE  WITH  RESPECT  TO  ITS 

  PRODUCTS. The sole and exclusive remedy of purchaser for any claim concerning this product, including but not limited to, 
 
claims alleging breach of warranty, negligence, strict liability or otherwise, is the replacement of product or refund of the 
  purchase price, at the sole option of Monarch. Any claims concerning this product must be received in writing within one 
(1) year from the date of shipment and any claims not presented within that period are waived by Purchaser. MONARCH 
  WILL  NOT  BE  RESPONSIBLE  FOR  ANY  SPECIAL,  INCIDENTAL,  CONSEQUENTIAL  (INCLUDING  LOST  PROFITS)  OR  PUNITIVE 
DAMAGES OF ANY KIND. Purchaser must determine the suitability of the products for the intended use and assumes all 
 
risks  and  liabilities  in  connection  therewith.  This  information  and  all  further  technical  advice  are  based  on  Monarch's 
  Present  knowledge  and  experience.  However,  Monarch  assumes  no  liability  for  providing  such  information  and  advice 
including the extent to which such information and advice may relate to existing third party intellectual property rights, 
  especially patent rights, nor shall any legal relationship be created by or arise from the provision of such information and  
advice. Monarch reserves the right to make any changes according to technological progress or further developments. The 
  purchaser  of  the  product(s)  must  test  the  product(s)  for  suitability  for  the  intended  application  and  purpose  before 

  proceeding  with  a  full  application  of  the product(s).  Performance  of  the  product  described  herein should  be  verified  by 
Product Order Information

Product Name  Product Code   Product Pack Size  


MonoGrout GP  11803  25 kg 

Monarch Industrial Products (I) Pvt Ltd,       No 25 SIDCO Industrial Estate, Theni.   Tel : +91 4546 251020 /250076 /250086

Fax No:+91 4546 253060, ToolFree:1800 425 1070   Website : www.monarchindia.net 

Vous aimerez peut-être aussi