Gaseous precision expansive non shrink cementitious Grout
TECHNICAL DATA SHEET
Description: MonGrout GP , precision grouting is supplied as a ready to use dry powder. The addition of a
controlled amount of clean water produces a free flowing, non‐shrink grout for gap thicknesses up to 100mm.
MonGrout GP is a blend of Portland cement, graded fillers and chemical additives which impart controlled
expansion in the plastic state whilst minimising water demand. The low water demand ensures high early
strength. The graded fillers are designed to assist uniform mixing and produce a consistent grout
Typical Applications Product Features
Turbines Gaseous expansion system compensates
for shrinkage and settlement in the plastic
Compressors
state
Boiler
No metallic iron content to cause staining
Feed Pumps
Pre‐packed material overcomes onsite
It can also be used for anchoring a wide range batching variations
of fixings.
Develops high early strength without the
These include masts, anchor bolts and fence use of chlorides
posts
High ultimate strength ensure the durability
Duct grouting. of the hardened grout
Non‐shrink infilling and jointing. Free flow ensures high level of contact with
Grouting tunnel linings. load bearing area
Product Image
Properties Standard Unit Values
Base Chemical additives modified
~ ~
Cementious system
Color
ASTM D 1544
~ Grey
Appearance ASTM D 1544 ~ Free Flowing Dry Powder
Fresh Wet Density (approx. depend 2242
ASTM D 1475 Kg/m3
upon the actual consistency used)
Typical Properties
Application Instructions
Foundation surface
The substrate surface must be free from oil, grease or any loosely adherent material. If the
concrete surface is defective or has laitence, it must be cut back to a sound base. Bolt holes
and fixing pockets must be blown clean of any dirt or debris.
Pre‐soaking
Several hours prior to placing, the concrete substrates should be saturated with fresh water.
Immediately before grouting takes place any free water should be removed with particular
Surface Preparation
care being taken to blow out all bolt holes and pockets.
Base plate
It is essential that this is clean and free from oil, grease or scale. Air pressure relief holes
should be provided to allow venting of any isolated high spots.
Levelling shims
If these are to be removed after the grout has hardened, they should be treated with a thin
layer of grease.
Formwork
The formwork should be constructed to be leak proof. This can be achieved by using foam
rubber strip or mastic sealant beneath the constructed formwork and between joints. In some
cases it is practical to use a sacrificial semi‐dry sand and cement formwork. The formwork
should include outlets for pre‐soaking.
For best results a mechanically powered grout mixer should be used.
When quantities up to 50kg are used, a heavy duty slow speed drill (400‐500 rpm) fitted with
a paddle is suitable..
Larger quantities will require a heavy duty mixer.
Mixing
To enable the grouting operation to be carried out continuously, it is essential that sufficient
mixing capacity and labour are available.
The use of a grout holding tank with provision to gently agitate the grout may be required.
Flowable (W/P 0.18)
Pourable (W/P 0.165)
Application :
At 30 C place the grout within 20 minutes of mixing to gain full benefit of the expansion
process.
MonGrout GP can be placed in thicknesses up to 100mm in a single pour when used as an
under plate grout.
For thicker sections it is necessary to fill out MonGrout GP with well graded silt free aggregate
Application Instructions
to minimise heat build up.
Typically a 10mm aggregate is suitable. 50 ‐ 100% aggregate weight of MonGrout GP can be
added.
Any bolt pockets must be grouted prior to grouting between the substrate and the base plate.
Continuous grout flow is essential. Sufficient grout must be prepared before starting. The time
taken to pour a batch must be regulated to the time to prepare the next one
Where large volumes have to be placed MonGrout GP may be pumped. A heavy duty
diaphragm pump is recommended for this purpose. Screw feed and piston pumps may also be
suitable.
Product Limitation
Application should not be undertaken if the temperature is 10°C and falling, nor when the
prevailing relative humidity exceeds 90%.
Higher temperatures will shorten curing time and conversely, lower temperatures and high
relative humidity will lengthen curing time.
MonoGrout GP is supplied ready‐to‐use on site. Never add cement or aggregates to
MonoGrout GP
Shelf Life &Storage
MonoGrout GP has a shelf life of 6 months if kept in a dry store in sealed bags. If stored in high
temperature and high humidity locations, the shelf life may be reduced. If stored at high
temperatures the shelf life may be reduced.
LIMITED WARRANTY NOTICE
Monarch warrants this product to be free from manufacturing defects and to meet the technical properties on the current
Technical Data Sheet, if used as directed within shelf life. Satisfactory results depend not only on quality products but also
upon many factors beyond our control. MONARCH MAKES NO OTHER WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS
PRODUCTS. The sole and exclusive remedy of purchaser for any claim concerning this product, including but not limited to,
claims alleging breach of warranty, negligence, strict liability or otherwise, is the replacement of product or refund of the
purchase price, at the sole option of Monarch. Any claims concerning this product must be received in writing within one
(1) year from the date of shipment and any claims not presented within that period are waived by Purchaser. MONARCH
WILL NOT BE RESPONSIBLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL (INCLUDING LOST PROFITS) OR PUNITIVE
DAMAGES OF ANY KIND. Purchaser must determine the suitability of the products for the intended use and assumes all
risks and liabilities in connection therewith. This information and all further technical advice are based on Monarch's
Present knowledge and experience. However, Monarch assumes no liability for providing such information and advice
including the extent to which such information and advice may relate to existing third party intellectual property rights,
especially patent rights, nor shall any legal relationship be created by or arise from the provision of such information and
advice. Monarch reserves the right to make any changes according to technological progress or further developments. The
purchaser of the product(s) must test the product(s) for suitability for the intended application and purpose before
proceeding with a full application of the product(s). Performance of the product described herein should be verified by
Product Order Information
Monarch Industrial Products (I) Pvt Ltd, No 25 SIDCO Industrial Estate, Theni. Tel : +91 4546 251020 /250076 /250086