Vous êtes sur la page 1sur 332

Consolidated Product Manual December 2008

Vickers Screw-in
Cartridge Valves
Solenoid Valves
Ø
Valve locator

2-way, 2-position
normally closed
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated
(restricted reverse flow when energized) L/min (USgpm) bar (psi)
SV11-10-C/CM* C-10-2 45 (12) 350 (5000) A-16
SV12-10-C/CM* C-10-2 23 (6) 350 (5000) A-22
2

FLOW TYPICAL
1 MODEL CAVITY RATING PRESSURE PAGE
Spool type, direct acting L/min (USgpm) bar (psi)
SV14-8-C/CM* C-8-2 11 (3) 350 (5000) A-44
2
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Poppet type, pilot operated L/min (USgpm) bar (psi)
1
SV13-10-C/CM* C-10-2 45 (12) 350 (5000) A-26
SV3-12-C/CM*/CR* C-12-2 114 (30) 210 (3000) A-28
C-12-2-U
2 SV2-20-C/CM*/CR*† C-20-2 227 (60) 210 (3000) A-38

Bi-directional, 2-way,
2-position normally closed
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated
SBV11-10-C C-10-2 76 (20) 350 (5000) A-18

2-way, 2-position
normally open
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated L/min (USgpm) bar (psi)
SV15-10-O/OP*/OS* C-10-2 45 (12) 350 (5000) A-62

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
1 Spool type, direct acting L/min (USgpm) bar (psi)
SV14-8-O/OM* C-8-2 13 (4) 350 (5000) A-82
SV14-10-O/OM* C-10-2 23 (6) 350 (5000) A-86
2

†Explosion proof, CSA Approved, coil option available (see page C-11)
*M = Manual override, *P = Push type manual override, *S = Screw type manual override, *R = Pull type manual override

EATON Vickers Screw-in Cartridge Valves QSG December 2008 1


Solenoid Valves
(cont.)
Valve locator

2-way, 2-position
normally open
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
Poppet type, pilot operated L/min (USgpm) bar (psi)
SV13-10-O/OP*/OS* C-10-2 45 (12) 350 (5000) A-58
SV3-12-O/OP*/OS* C-12-2 114 (30) 210 (3000) A-66
1 C-12-2U
SV13-16-O/OP*/OS* C-16-2 132 (35) 350 (5000) A-74
SV3-20-O/OP*/OS*† C-20-2 227 (60) 210 (3000) A-76
2 SV13-20-O/OP*/OS* C-20-2 227 (60) 350 (5000) A-78

Bi-directional, 2-way,
2-position normally open
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated L/min (USgpm) bar (psi)
SBV11-8-O C-8-2 60 (15) 350 (5000) A-54
SBV11-10-O C-10-2 76 (20) 350 (5000) A-64
2

3-way, 2-position
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 Spool type, direct acting L/min (USgpm) bar (psi)
SV11-8-3/3M* C-8-3 11 (3) 350 (5000) A-90
SV11-10-3/3M* C-10-3 23 (6) 350 (3000) A-96
3 1 SV1A/B-12-3P C-12-3 42 (11) 210 (3000) A-100
c
Flow port 1 to port 2 not to exceed 10 L/min (2.5 USgpm)

FLOW TYPICAL
2 MODEL CAVITY RATING PRESSURE PAGE
Spool type, direct acting L/min (USgpm) bar (psi)
SV2A/B-12-3P C-12-3 38 (10) 210 (3000) A-102

3 1

FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2
Spool type L/min (USgpm) bar (psi)
SV4A/B-12-3P C-12-3 42 (11) 210 (3000) A-104
C
Port 1 must be vented to tank. Tank pressure not to exceed 13,7 bar (200 psi)
3 1

†Explosion proof, CSA Approved, coil option available (see page C-11)
*M = Manual override, *P = Push type manual override, *S = Screw type manual override, *R = Pull type manual override

2 EATON Vickers Screw-in Cartridge Valves QSG December 2008


Solenoid Valves
Ø
(cont.)
Valve locator

4-way, 2-position
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
2 4 Spool type, direct acting L/min (USgpm) bar (psi)
SV11-8-4/4M* C-8-4 11 (3) 350 (5000) A-108
SV11-10-4/4M* C-10-4 23 (6) 350 (5000) A-116
3 1

FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2 4 Spool type, direct acting L/min (USgpm) bar (psi)
SV12-8-4/4M* C-8-4 13 (4) 350 (5000) A-112
SV2A/B-12-4P C-12-4 53 (14) 210 (3000) A-128
3 1

FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2 4 Spool type L/min (USgpm) bar (psi)
SV3-10-4/4M*/4R*† C-10-4 23 (6) 210 (3000) A-120
SV3A/B-12-4P C-12-4 53 (14) 210 (3000) A-130
3 1

2 4 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Spool type, selector valve L/min (USgpm) bar (psi)
SV4-10-4/4M*/4R*† C-10-4 23 (6) 210 (3000) A-122
3 1

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Spool type, selector valve L/min (USgpm) bar (psi)
SV5-10-4/4M*/4R* C-10-4 23 (6) 210 (3000) A-124
3 1 SV5A/B-12-4P C-12-4 53 (14) 210 (3000) A-132

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Spool type L/min (USgpm) bar (psi)
SV7A/B-12-4P C-12-4 46 (12) 210 (3000) A-134

3 1

†Explosion proof, CSA Approved, coil option available (see page C-11)
*M = Manual override, *P = Push type manual override, *S = Screw type manual override, *R = Pull type manual override

EATON Vickers Screw-in Cartridge Valves QSG December 2008 3


Directional
Controls
Valve locator

Manually operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 Pull-to-open, 2-way, 2 position L/min (USgpm) bar (psi)
MPV1-10 C-10-2 45 (12) 210 (3000)* D-38
MPV3-10 (detent) C-10-2 45 (12) 210 (3000)* D-40
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 3 Manual rotary, 3-position detent L/min (USgpm) bar (psi)
MRV3-10-D/E C-10-3 23 (6) 210 (3000)* D-4
MRV3-16-D C-16-3 64 (17) 210 (3000)* D-6
1
FLOW TYPICAL
2 MODEL CAVITY RATING PRESSURE PAGE
Push-to-open, 3-way, 2 position L/min (USgpm) bar (psi)
MSV1-12 C-12-3 42 (11) 210 (3000) D-42
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2
Push-to-open, 3-way, 2 position L/min (USgpm) bar (psi)
MSV2-12 C-12-3 38 (10) 210 (3000) D-44
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2
Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV3-12 C-12-4 53 (14) 210 (3000) D-48
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2 Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV4-12 C-12-4 53 (14) 210 (3000) D-50
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2
Push-to-open, 3-way, 2 position L/min (USgpm) bar (psi)
MSV5-12 C-12-3 42 (11) 210 (3000) D-46
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV6-12 C-12-4 53 (14) 210 (3000) D-52
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4 Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV7-12 C-12-4 45 (12) 210 (3000) D-54
3 1 FLOW TYPICAL
MODE CAVITY RATING PRESSURE PAGE
2 4
Manual lever, 4-way, 3 position L/min (USgpm) bar (psi)
MLV9-12-A C-12-4 60 (15) 210 (3000) D-32
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Manual lever, 4-way, 3 position L/min (USgpm) bar (psi)
MLV9-12-E C-12-4 60 (15) 210 (3000) D-34
3 1

4 EATON Vickers Screw-in Cartridge Valves QSG December 2008


Directional
Ø
Controls (cont.)
Valve locator

Manually operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
Manual rotary, 4-way, 3-position detented L/min (USgpm) bar (psi)
4 2
MRV5-10-D/E C-10-4 11 (3) 210 (3000) D-12
MRV5-16-D C-16-4 45 (12) 210 (3000) D-14
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2
Manual rotary, 4-way, 3-position detented L/min (USgpm) bar (psi)
MRV6-10-D/E C-10-4 11 (3) 210 (3000) D-16
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Manual rotary, 4-way, 3-position detented L/min (USgpm) bar (psi)
4 2
MRV4-10-D/E C-10-4 11 (3) 210 (3000) D-8
MRV4-16-D C-16-4 45 (12) 210 (3000) D-10
* Indicates that these models are available for use above 210 bar (3000 psi). However, caution should be taken and a review of the
3 1 application may be necessary prior to use. Contact your Eaton sales engineer.

Pilot operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
External pilot, atmospheric vent, 3 way, 2 position L/min (USgpm) bar (psi)
3
1 PTS1-10 C-10-4 30 (8) 210 (3000) D-56
PTS1-16 C-16-4 132 (35) 210 (3000) D-58
2 4 PTS1-20 C-20-4 265 (70) 210 (3000) D-60
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
3 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
1
PTS2-16 C-16-4 132 (35) 210 (3000) D-64
PTS2-20 C-20-4 265 (70) 210 (3000) D-66
2 4
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE

3 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
1 PTS3-16 C-16-4 132 (35) 210 (3000) D-70
PTS3-20 C-20-4 265 (70) 210 (3000) D-72
2
4

EATON Vickers Screw-in Cartridge Valves QSG December 2008 5


Directional
Controls (cont.)
Valve locator

Pilot operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
2 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
4
PTS5-10 C-10-3 11 (3) 210 (3000) D-76

3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
3
External pilot, atmospheric vent, 3 way, 2 position L/min (USgpm) bar (psi)
1
PTS5-16 C-16-4 132 (35) 210 (3000) D-78
2 4

FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2
4 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
PTS6-16 C-16-4 132 (35) 210 (3000) D-82
3 1

FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
Dual External pilot, 3 way, 2 position L/min (USgpm) bar (psi)
4 2 PTS9-8 C-8-5S 19 (5) 280 (4000) D-86
5 1 PTS9-10 C-10-5S 38 (10) 280 (4000) D-88
PTS9-12 C-12-5S 76 (20) 280 (4000) D-90
3 PTS9-16 C-16-5S 151 (40) 280 (4000) D-92
PTS9-20 C-20-5S 228 (60) 280 (4000) D-94

Manually operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE

2 Direct acting, ball type L/min (USgpm) bar (psi)


DSV2-8 C-8-3 23 (6) 240 (3500) D-20
1 3

6 EATON Vickers Screw-in Cartridge Valves QSG December 2008


Proportional
Ø
Controls
Valve locator

Electrohydraulic pressure
reducing/relieving
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
RP Internal pilot, spool type L/min (USgpm) bar (psi)
EPRV1-16 C-16-3 38 (10) 35 (500) B-60

P T
Electrohydraulic
Proportional Relief
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2-stage, pilot operated L/min (USgpm) bar (psi)
ERV1-10 C-10-2 4-57 (1-15) 210 (3000) B-50
1 ERV1-16 C-16-2 8-132 (2-35) 210 (3000) B-52
2

Electrohydraulic Flow
Regulator
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Promotional, 2-way, normally closed popet type
ESV1-8*-C C-8-2 71 (19) 210 (3000) B-18
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 Nose in, side out L/min (USgpm) bar (psi)
EPV16-A C-16-3S (modified) 0-160 (0-42) 280 (4000) B-10
1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
3 1 Side in, nose out L/min (USgpm) bar (psi)
EPV16-B C-16-3S (modified) 0-160 (0-42) 280 (4000) B-10
2 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
3
Direct acting L/min (USgpm) bar (psi)
EFV1-10*-C C-10-3 38 (10) 210 (3000) B-31
1
EFV1-12*-C C-12-3 77 (20) 210 (3000) B-37
2
FLOW TYPICAL
1 MODEL CAVITY RATING PRESSURE PAGE
L/min (USgpm) bar (psi)
EFV2-12*-C C-12-3 114 (30) 210 (3000) B-43

FLOW TYPICAL
2 3 MODEL CAVITY RATING PRESSURE PAGE
2 Direct acting L/min (USgpm) bar (psi)
EFV1-10*-O C-10-3 38 (10) 210 (3000) B-28
EFV1-12*-O C-12-3 104 (27.5) 210 (3000) B-34
1
3
FLOW TYPICAL
1 MODEL CAVITY RATING PRESSURE PAGE
Side in, nose out L/min (USgpm) bar (psi)
EFV2-12*-0 C-12-3 114 (30) 210 (3000) B-40

2 3 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Promotional, 2-way, normally open popet type
ESV1-8*-O C-8-2 60 (16) 210 (3000) B-16
ESV1-10*-O C-10-2 98 (26) 210 (3000) B-20
ESV1-12*-O C-12-2 128 (34) 210 (3000) B-24

EATON Vickers Screw-in Cartridge Valves QSG December 2008 7


Pressure
Controls
Valve locator

Pressure reducing/relieving
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Pilot operated
PRV2-16 C-16-3 151 (40) 350 (5000) E-48
3
2 1

Pressure sequence valves


FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
External pilot, sliding spool direct acting L/min (USgpm) bar (psi)
PSV2-8 C-8-3 23 (6) 210 (3000) E-50
3 PSV4-8 C-8-3 15 (4) 350 (5000) E-52
2
1
Accumulator
discharge valve
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
3 External pilot to close (100:1 ratio) L/min (USgpm) bar (psi)
ADV1-16 C-16-3S 30 (8) 210 (3000) E-76
1 2

Relief valves
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
Poppet, differential area L/min (USgpm) bar (psi)
2 1 RV3-10 C-10-2 76 (20) 250 (3600) E-14

FLOW TYPICAL
1 2 MODEL CAVITY RATING PRESSUREPAGE
Poppet type, direct acting, thermal relief check valve L/min (USgpm) bar (psi)
RV4-10 C-10-2 45 (12) 350 (5000) E-22

8 EATON Vickers Screw-in Cartridge Valves QSG December 2008


Flow Controls
Ø
Valve locator

Flow restrictors,
knob/lever operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Manual rotary L/min (USgpm) bar (psi)
MRV2-10-K C-10-2 60 (15) 210 (3000) F-38
1 2 MRV2-10-B/E/D/L C-10-2 60 (15) 210 (3000) F-38
MRV2-16-K C-16-2 170 (45) 210 (3000) F-40
MRV2-16-B/E/D/L C-16-2 170 (45) 210 (3000) F-40

Flow restrictors,
adjustable
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Needle valve L/min (USgpm) bar (psi)
1 2 NV1-10 C-10-2 45 (12) 210 (3000) F-44

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Needle valve, restricted reverse flow L/min (USgpm) bar (psi)
1 2
NV1-16 C-16-2 151 (40) 210 (3000) F-46
NV1-20 C-20-2 265 (70) 210 (3000) F-48

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Needle type L/min (USgpm) bar (psi)
FCV11-12 C-12-2 114 (30) 350 (5000) F-52
1 2 C-12-2U
FCV6-16 C-16-2 208 (55) 210 (3000) F-54

Flow regulators
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE

2 (pressure compensated) Two way, pre-set flow L/min (USgpm) bar (psi)
FR5-8 C-8-2 10 (2.5) 350 (5000) F-4
FR1-16 C-16-2 113 (30) 210 (3000) F-8
FR1-20 C-20-2 227 (60) 210 (3000) F-10
1
FLOW TYPICAL
2 MODEL CAVITY RATING PRESSURE PAGE
(pressure compensated) Two-way, adjustable flow regulator L/min (USgpm) bar (psi)
FR2-16 C-16-2 113 (30) 210 (3000) F-14

1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Pressure compensated flow regulator L/min (USgpm) bar (psi)
FAR1-10 C-10-2 1 - 38 (25 - 10) 350 (5000) F-16
1 2 FAR1-12 C-12-2 1,5 - 94,5 (0,44 - 25) 350 (5000) F-18
C-12-2U
FAR1-16 C-16-2 3,8 - 15,1 (1.0-4.0) 350 (5000) F-20

EATON Vickers Screw-in Cartridge Valves QSG December 2008 9


Flow Controls
(cont.)
Valve locator

Flow regulators MAX MAX


REG. INLET TYPICAL
Functional Symbol MODEL CAVITY FLOW FLOW PRESSURE PAGE
3-way priority flow regulator (fixed setting) L/min (USgpm) bar (psi)
1 3 PFR5-8 C-8-3 10 (2.5) 15 (4) 350 (5000) F-22
PFR5-10 C-10-3 23 (6) 60 (15) 350 (5000) F-24
2

MAX MAX
REG. INLET TYPICAL
1 3 MODEL CAVITY FLOW FLOW PRESSURE PAGE
3-way priority flow regulator L/min (USgpm) bar (psi)
50% adjustable
2 PFR2-16 C-16-3 114 (30) 151 (40) 210 (3000) F-30
CF EF
4 2
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
LS 5 1
Dynamic Signal (PFRD) L/min (USgpm) bar (psi)
PFRD-12 C-12-5S 76 (20) 280 (4000) F-32
3 P PFRD-16 C-16-5S 150 (40) 280 (4000) F-34
PFRD-20 C-20-5S 230 (60) 240 (3500) F-36
CF EF Static Signal (PFRS)
4 2
PFRS-12 C-12-5S 76 (20) 280 (4000) F-32
LS 5 1 PFRS-16 C-16-5S 150 (40) 280 (4000) F-34
PFRS-20 C-20-5S 230 (60) 240 (3500) F-36

3 P

Flow dividers
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 4 Flow divider/combiner L/min (USgpm) bar (psi)
FDC1-20 manifold 378 (100) 210 (3000) F-70

3
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2 Posi-trachon valve L/min (USgpm) bar (psi)
FDC3-20 manifold 567 (150) 210 (3000) F-80

10 EATON Vickers Screw-in Cartridge Valves QSG December 2008


Check Valves
Ø
Valve locator

Direct operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Direct acting, poppet type L/min (USgpm) bar (psi)
CV3-4 C-4-2 8 (2) 350 (5000) G-4
2 1 CV11-12 C-12-2, C-12-2U 114 (30) 350 (5000) G-14

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
1 2 Direct acting, poppet type L/min (USgpm) bar (psi)
CV16-10 C-10-2 76 (20) 350 (5000) G-12

FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE

1 2 Direct acting, poppet type with orifice L/min (USgpm) bar (psi)
CV6-10 C-10-2 76 (20) 350 (5000) G-20
CV6-16 C-16-2 151 (40) 210 (3000) G-22

EATON Vickers Screw-in Cartridge Valves QSG December 2008 11


Logic Elements
Valve locator

Differential pressure
FLOW TYPICAL
sensing MODEL CAVITY RATING PRESSURE PAGE
Differential pressure sensing, spool type L/min (USgpm) bar (psi)
DPS2-10 C-10-3S 57 (15) 240 (3500)* I-12
DPS2-12 C-12-3S 114 (30) 240 (3500)* I-14
DPS2-16 C-16-3S 190 (50) 240 (3500)* I-16
DPS2-20 C-20-3S 303 (80) 240 (3500)* I-18
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Differential pressure sensing, poppet type L/min (USgpm) bar (psi)
DPS2-10 C-10-3S 57 (15) 350 (5000) I-12
DPS2-16 C-16-3S 190 (50) 350 (5000) I-16
DPS2-20 C-20-3S 303 (80) 350 (5000) I-18
Functional Symbols * Indicates that these models are available for use above 240 bar (3500 psi). However, caution should be taken and a review of the
Spool type application may be necessary prior to use. Contact your Eaton applications engineer.
2 1 2 3 1

1 3 2 3 1 2 3
DPS2-**-F DPS2-**-P DPS2-**-R DPS2-**-V
Spool, flow control, Spool, Spool, pressure reducing, Spool, normally
normally open normally closed normally open closed
Poppet type
1 2
1

2 3
2 3 1 3
DPS2-**-B DPS2-**-S DPS2-**-T
Poppet, vent to open, Poppet, vent to open, Poppet, bi-directional pilot to close, 2:1 ratio,
normally closed normally closed normally closed

Pressure compensators,
restrictive
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Compensator spool element, restrictive type L/min (USgpm) bar (psi)
PCS3-12 C-12-3 58 (15) 210 (3000) I-24
3 2 PCS3-16 C-16-3 114 (30) 210 (3000) I-26
PCS3-20 C-20-3 189 (50) 210 (3000) I-28
1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Compensator spool element, priority type L/min (USgpm) bar (psi)
PCS4-10 C-10-4 38 (10) 210 (3000) I-30
4 3 PCS4-12 C-12-4 58 (15) 210 (3000) I-32
PCS4-16 C-16-4 114 (30) 210 (3000) I-34
1 2 PCS4-20 C-20-4 189 (50) 210 (3000) I-36

12 EATON Vickers Screw-in Cartridge Valves QSG December 2008


Pressure
Controls
Section introduction

This section gives basic • Pilot operated poppet Reducing Valves Accumulator Unloading
specifications for Vickers type with reverse free- Two types are available: Valves
pressure control threaded flow check – RV2 Valves that allow accumula-
cartridge valves. Its pur- • Direct operated with
Use as a service line relieving feature – PRV1 tors to be charged to a pre-
pose is to provide a quick, relief where anticavita- selected maximum pres-
convenient reference tool tion make-up is required. • Pilot operated with sure at which the pump is
when choosing Vickers car- It may also be applied as relieving feature – PRV2 unloaded. The pump does
tridge valves or designing a an internally piloted and PRV12 not cut-in until the accumu-
system using these compo- counterbalance valve in a lator pressure has decayed
nents. • Pilot operated without
service line. relieving feature to a pre-selected percent-
Eaton offers a full range • Direct operated poppet age of maximum pressure.
of Vickers direct and pilot type, differential area Sequence Valves The low-flow PUV3 model
operated relief, reducing, models – RV3 and RV8 can be used as a stand E
sequence and unloading A complete range of alone model for low flow
valves. In general, the Sometimes termed a sequence functions is applications, or as a pilot
direct operated products “differential area relief available, including: stage in two-stage arrange-
are faster in response while valve”. A fast acting valve, • Normally-closed and ments for higher flows.
pilot operated types have highly tolerant of contam- normally-open models
a flatter pressure/flow inant and providing an Accumulator Discharge
alternative flow path, • Internal and external
characteristic. pilot options Valve
frequently beneficial in
This valve is designed to
Relief Valves manifold layout. Utilized • Internal and external
ensure that an accumulator
in CRV3 cross-line drain options
When selecting a relief will discharge when pilot
relief packages. • Two and three
valve for a specific applica- pressure is lost, e.g. on
tion, consideration should • Pilot operated spool position models pump shutdown.
be given to the following type – RV5 and RV11 Externally drained models
• Direct operated poppet Well suited for repetitive, may be used as relief Fluid Cleanliness
types – RV1 and RV10 continuous duty with a valves in circuits with alter- Proper fluid condition
low pressure-override nating pressure and tank is essential for long and
Suitable for continuous characteristic. line functions.
duty with reliable fast satisfactory life of hydraulic
response, the RV10 • Direct operated ball components and systems.
being a low pressure, type – RV6 Hydraulic fluid must have
low cost option. These A fast-acting valve for the correct balance of
valves are also suitable intermittent duty. This cleanliness, materials, and
for piloting the DPS2 low flow, low cost valve additives for protection
logic elements. may be used as a pilot against wear of compo-
section for a larger main- nents, elevated viscosity,
stage valve, or piloting and inclusion of air.
logic elements.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-3


RV4-10
Thermal relief with reverse
flow check valve

Description Operation
The RV4-10-F is a direct act- This valve has a dual func- is overcome at port 1. The The valve remains closed
ing, poppet type, screw-in tion. In the first function poppet is unseated and until the predetermined set-
cartridge type thermal relief the valve acts as a check allows flow from port 1 to ting is reached. The valve
with reverse flow check valve and remains closed port 2. The second function allows expansion flow from
valve. until the spring bias acts as a thermal relief. port 2 to port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
1 2 Typical application pressure (all ports) 350 bar (5000 psi)
Rated flow – check valve 45 L/min (12 USgpm)
– relief valve 1 L/min (0.25 USgpm)
Relief cracking pressure ranges 28 - 350 bar (400 - 5000 psi)
Check valve cracking pressure 1,24 bar (18 psi)
Reseat pressure More than 90% of cracking pressure
Internal leakage, port 2 to port 1 5 drops/min at cracking pressure
Sectional View Cavity C-10–2
Standard housing materials Aluminum or steel
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,11 kg (0.25 lbs)
Seal kits 565803 Buna–N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Override &


2 Free Flow Curves
Cartridge only

1
ThermalThermal
Relief (port
Relief
2-port
(port1)2-port 1) Free Flow
Free
(port
Flow1-port
(port2)1-port 2)
Flow L/min
Flow(21,8
L/mincSt
(21,8
oil @cSt
49°C)
oil @ 49°C) Flow (21,8
Flow - L/min - L/min (21,8
cSt oil @cSt oil @ 49°C)
49°C)
0 1 0 21 32 4 3 54 6 5 7 6 7 0 8 0 168 2416 3224 4032 4840 5648 56
5000 5000 350 350 100 100 7 7
Pressure Drop - psi

Pressure Drop - psi

300 300
Pressure Override - psi

Pressure Override - psi

4000 4000 6 6
Pressure Drop - bar

Pressure Drop - bar

80 80
250 250 5 5
3000 3000 60 60
200 200 4 4
2000 2000 150 150 40 40 3 3
100 100 2 2
1000 1000 20 20
50 50 1 1
0 0 0 0 0 0 0 0
0 0 0.5 0.51.0 1.01.5 1.5 0 2 0 4 2 6 4 8 6 10 8 121014 12 14
Flow - USgpm
Flow - USgpm
(105 SUS
(105
oil SUS
@ 120°F)
oil @ 120°F) Flow - USgpm
Flow - USgpm (105
(105 SUS oil SUS oil @ 120°F)
@ 120°F)

E-22 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code RV4-10

RV4 – 10 (V) – F – (S) – ** – 50 / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port size

RV - Check valve w/thermal 0 - Cartridge only


relief
CODE PORT SIZE HOUSING NUMBER E
Aluminum Aluminum Steel
2 Size Light duty Fatigue rated Fatigue rated

10 - 10 Size 3B 3/8” BSPP 02–175462 – –


2G 1/4” BSPP – 876702 02–175102
3G 3/8” BSPP – 876703 02–175103
3 Seals 6H SAE 6 – 876700 –
Blank - Buna–N 8H SAE 8 – 876701 –
V - Viton®
6T SAE 6 566151 – 02–175100
8T SAE 8 – – 02–175101
4 Adjustment
See section J for housing details.
F - Factory set

5 Valve housing 7 Cracking pressure range 8 Setting pressure 9 Special features


material 50 - 28-350 bar Within ranges in 7 00 - None
Blank - Aluminum (400-5000 psi) (Only required if valve has
S - Steel User must specify settings special features, omitted
in 7 bar (100 psi) steps, if “00”)
coded as in the following
examples:
10 - 70 bar (1000 psi)
25 - 175 bar (2500 psi)

Dimensions
mm (inch)

Torque cartridge in housing 19,1


(0.75) 25,4 (1.0) hex
A - 47-54 Nm (35-40 ft. lbs)
S - 68-75 Nm (50-55 ft. lbs)
Aluminum
0.875"-14 Thd. housings can
31,7 • be used for
(1.25) pressures up
2 to 210 bar (3000 psi).
Steel housings must be
used for operating pres-
1 sures above 210 bar
Ø 15,80 (0.622) (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-23


ADV1-16
Accumulator discharge
valve

Description Operation
The ADV1-16 is a poppet In its unpiloted position,
type, normally open, exter- this valve remains open
nally piloted, screw-in car- between port 1 and port 2
tridge type accumulator dis- until sufficient pilot pres-
charge valve. sure is applied to port 3.
Flow is then blocked from
port 1 to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
1 2 Rated flow 30 L/min (8 USgpm)
Minimum pilot pressure @ port 3 4 bar (60 psi)
Cavity C-16–3S
Standard housing materials Aluminum
Sectional View Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Pilot ratio 100:1
Weight cartridge only 0,28 kg (0.62 lbs)
Seal kits 565812 Buna–N
889611 Viton®
3 Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)


2 Cartridge only 0 5 10 15 20 25 30
3000 200
Port 3 pilot pressure = 0
2500
Pressure Drop - psi

150 Pressure Drop - bar


1
2000

1500 100

1000
50
500

0 0
0 2 4 6 8
Flow - USgpm (105 SUS oil @ 120°F)

E-76 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code ADV1-16

ADV1 – 16 – (V) – *** – 100 – 00

1 2 3 4 5 6

1 Function 4 Port size 5 Pilot area ratio


ADV1 - Accumulator 0 - Cartridge only Port 3: Port 1 - 100:1
discharge valve CODE PORT SIZE HOUSING NUMBER (Minimum pilot pressure at
port 3 - 4 bar (60 psi)
2 Size
Aluminum Aluminum E
Light duty Fatigue rated
16 - 16 Size 6B 3/4” BSPP 02–175471 –
6 Special features

3 12T SAE 12 566414 – 00 - None


Seals (Only required if valve has
Blank - Buna-N 4G 1/2” BSPP – 02–160676 special features, omitted
V - Viton® 6G 3/4” BSPP – 876726 if “00”)
10H SAE 10 – 876725
12H SAE 12 – 876727
See section J for housing details.

12,0
Dimensions
(0.47)
mm (inch)

Torque cartridge in housing


108-122 Nm (80-90 ft. lbs) 38,1 (1.50) hex

1.312 " -12 Thd.


3
55,3
(2.17)

1
Ø 25,37 (0.999)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-77


PRV2-16
Pressure reducing/
relieving valve
Pilot operated

Description Operation
The PRV2-16 is a pilot This valve is normally open, the spool shifts to restrict setting of the valve, the
operated, spool type allowing flow from port 2 to the inlet flow at port 2. This spool will shift further and
screw-in cartridge pressure port 1. Port 3 must be vent- regulates the pressure at relieve excess pressure
reducing/relieving valve. ed. Once the pressure set- port 1. If pressure at port 1 through port 3.
ting is reached at port 1, exceeds the predetermined

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure(all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
3
Rated flow 151 L/min (40 USgpm)
2 1
Cavity C-16–3
Standard housing materials Aluminum or steel
Temperature range -40° to 120˚C (-40° to 248˚F)
Sectional View
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,40 kg (0.89 lbs)
Seal kits 565811 Buna–N
889610 Viton®
Viton is a registered trademark of E.I. DuPont

Reduced Pressure Flow - L/min (21,8 cSt oil @ 49ºC)


Curve
150 100 50 0 50 100 150
Cartridge only
5000
3 350

Pressure, port 1 - bar


Pressure, port 1 - psi

4000 300
250
2
3000 200
150
1 2000
100
1000
50
0 0
40 30 20 10 0 10 20 30 40

Port 1 to 3 Port 2 to 1
Flow - USgpm (105 SUS oil @ 120ºF)

E-48 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PRV2-16

PRV2 – 16 (V) – * – (S) – *** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port size

PRV2 - Pressure 0 - Cartridge only


reducing/relieving valve CODE PORT SIZE HOUSING NUMBER
Aluminum Aluminum Steel
Light duty Fatigue rated Fatigue rated
2 Size
6B 3/4” BSPP 02–175465 – –
16 - 16 Size
4G 1/2” BSPP – 876720 02–175131
6G 3/4” BSPP – 876722 02–175132
3 Seals 10H SAE 10 – 876721 – E
Blank - Buna-N 12H SAE 12 – 876723 –
V - Viton® 10T SAE 10 – – 02–175129
12T SAE 12 566152 – 02–175130
4 Adjustment See section J for housing details.
C - Cap
K - Knob
S - Screw 7
Cracking pressure range 8 Factory set reduced 9 Special features

30 - 34-210 bar pressure 00 - None


(500-3000 psi) Within ranges in 7 (Only required if valve has
5 Valve housing material 60 - 70-415 bar Blank - Normal factory special features, omitted
S - Steel (1000-6000 psi) if “00”)
setting at approximate
A - Aluminum
mid-range. User requested
settings in 3,45 bar (50 psi)
steps, coded as in the
following examples:
10 - 70 bar (1000 psi)
10.5 - 72,4 bar (1050 psi)
"S" Adjustment
Dimensions 4,7 (0.18) hex "C" Adjustment "K" Adjustment
mm (inch)

Torque cartridge in housing


A - 108-122 Nm (80-90 ft. lbs)
S - 136-149 Nm (100-110 ft. lbs) 57,1 60,3
57,1
(2.25) (2.37)
(2.25)

38.1 (1.50) hex

1.312”-12 Thd.

71,5 3
(2.81) Aluminum
housings can
• be used for
2
pressures up
to 210 bar (3000 psi).
Steel housings must be
1 used for operating pres-
Ø 26,95 (1.061)
sures above 210 bar
Ø 28,55 (1.124) (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-49


Check Valves

This section gives basic Pilot operated check shock is obtained through pressure spring option
specifications for the full valves the use of several standard for effective anti-
line of Vickers screw-in These valves are used for: cracking pressure ranges cavitation protection.
cartridge check valves. Its • Position load locking from 2,0 bar (30 psi) to 7 • Unique design provides
purpose is to provide a • As an alternative to bar (100 psi). When compact package and
quick, convenient reference counterbalance valves anti-cavitation protection is low pressure drops that
tool when choosing Vickers where neither the required, the 0,30 bar (5 match or exceed current
cartridge valves or design- overrunning loads or psi) spring should be used. market expectations and
ing a system using these release speed are For those applications provide for excellent
components. factors in the where pilot pressure may repeatability and stability.
The Vickers range of direct application. not always be available, the
valve can be ordered with • 3:1 pilot ratio satisfies
and pilot operated check simple load holding
valves provides the The high pressure POC*-10 an optional adjustable
override. application requirements,
hydraulic circuit designer and POC*-12 series of while providing smooth
with a wide selection of pilot-to-open check valves Features and benefits operation and longer
cartridge and in-line complement the CBV*-10 • Products in this catalog operating life.
products. and CBV*-12 have been fatigue tested
counterbalance cartridges • Optional adjustable
Two pressure ratings are for one million cycles at override releases the
shown for all products and are physically 132% or 10 million cycles
interchangeable with them. load for situations where
featured in this catalog. The at 115% of rated pilot pressure is not
typical application pressure pressure. always available.
rating is the maximum The POC’s provide a low
cost alternative to load • Simple load holding Single pilot check
recommended operating device. Low cost
pressure for the valve in a control when the dynamics Also offered are SPC2-8
given system. The fatigue of neither overrunning loads alternative to more G
complex solutions when and SPC2-10 single pilot
pressure rating is the nor load release speed are check valves with
factors to be considered in overrunning loads are not
pressure for the valve to be present and / or control pressures to 240 bar (3500
free for infinite life from the design of the hydraulic psi) and flows to 23 L/min
circuit for the load to be of load release speed is
metal fatigue. not required. (6 USgpm). These valves
controlled. operate similar to the POC1
All poppet type check valve • Provides high operational
cartridges have hardened product but offer an
The pilot-to-open valves efficiency and low spring opposite flow path which
and ground poppets and positively lock a load from settings.
sharp-edged ground steel offers the designer a choice
port 1 to port 2 until pilot • Valves are offered with a of pilot operated check
seats. This provides an pressure applied to port 3
excellent product that is wide variety of standard valve when laying out a
is sufficient to unseat the housings with SAE and custom manifold for ease
dirt-tolerant, has reliable valve. This then permits
seating, and is suitable for BSPP port options in the of design.
flow from port 1 to port 2. following configurations:
fast cycling with long life. The load can also be Supporting products
– In-line single
Direct operated check released through means of – In-line dual Vickers screw in
valves an optional screw type – SAE, 4-bolt, code 61 cartridge valves are avail-
override. – Close coupled, nipple able in a wide range of
Cartridges fit into industry mounted mounting configurations
standard cavities and may The POC*-10 covers flow – Gasket mounted single and porting options to
be supplied for installation in up to 60 L/min (15 USgpm). – Gasket mounted dual provide flexibility in
manifolds, or be provided in The POC*-12 covers flow developing circuits.
up to 114 L/min (30 These valves can also be Housings are available in
standard housings having used in a C–10–3S or
USgpm). With infinite life either aluminum 210 bar
SAE or BSPP ports suitable qualification to a fatigue C–10–3S cavity. (3000 psi) or steel 350 bar
for in-line mounting. pressure rating of 310 bar • Four standard cracking (5000 psi) configurations.
(4500 psi), these POC pressures permit energy All are available with a
A wide selection of cracking valves are suitable for use savings, while tailoring choice of BSPP
pressures is available from in a broad range of load the hydraulic system (ISO–0228/1) or SAE style
0,21 to 20,7 bar (3 to 300 control applications with requirements to minimize ports.
psi). Thus the opportunity typical system operating shock.
exists to use the valves not pressures up to 350 bar
• Unique dual spring design
only as conventional check (5000 psi). Tailoring of the
provides high operational
but also as low pressure circuit to gain energy
efficiency and a low
relief valves. savings while minimizing

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 G-3


CV3-4
Check valve

Description Operation
The CV3-4-B is a ball type, This valve remains closed poppet lifts off the seat and
screw-in cartridge check until the bias is reached at allows flow from port 1 to
valve. port 1 at which time the port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
1 2 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 7.6 L/min (2 USgpm)
Profile View Free flow cracking pressure @ 1 l/min (0.25 USgpm) 5 – 0,34 bar (5 psi)
Internal leakage, Port 2 to 1 5 drops/min maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–4–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,04 kg (0.09 lbs)
Seal kit 9900174-000 Buna–N
9900175-00 Viton®
Viton is a registered trademark of E.I. DuPont

2
Pressure Drop Curves Pressure vs. Flow - L/min (21,8 cSt oil @ 49° C)
Cartridge only 0 3.8 7.6
400 28

Pressure Drop - bar


Pressure Drop - psi

300 20

200 14

100 7

0
0 .5 1 1.5 2 2.5 3
Flow - USgpm (105 SUS oil @ 120° F)

G-4 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code CV3-4

CV3 – 4 (V) – B – *** – ** – 00

1 2 3 4 5 6 7

1 Function 3 Seals 5 Port size 7 Special features

CV3 - Check valve Blank - Buna-N 000 - Cartridge only 00 - None


V - Viton® (Only required if valve has
special features - omitted
2 Size 6 Free flow cracking if “00”)
4 Style pressure
4 - 4 Size
B - Ball type 05 - 0,34 bar (5 psi)

G
Dimensions
mm (inch) 9/16" HEX
Torque cartridge in 12,73
aluminum or steel housing (.501)
to 8.1-13.6 Nm (6-10 ft. lbs)

7/16 - 20 UNF - 2A

21,82
(.859)
2

1
Ø 8,64 (.340)

Aluminum housings can be used for


pressures up to 210 bar (3000 psi)
Steel housings must be used for operating
pressures above 210 bar (3000 psi)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 G-5


CV16-10
Check Valve
(side in, nose out)

Description Operation
The CV16-10-P is a poppet This valve remains closed time the poppet lifts off the
type, screw-in cartridge until the spring bias is seat and allows flow from
check valve. reached at port 2 at which port 2 to port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
2 1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 76 L/min (20 USgpm)
Free flow cracking pressure @1 L/min (0.25 USgpm) 5 – 0,34 bar (5 psi)
15 – 1,03 bar (15 psi)
25 –1,70 bar (25 psi)
50 – 3,40 bar (50 psi)
Sectional View Internal leakage, Port 2 to 1 5 drops / min. maximum @ 350 bar (5000 psi)
Temperature range –40˚ to 120˚C (–40˚ to 248˚F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,08 kg (0.17 lb)
Seal kit 565803 Buna–N
566086 Viton®
Viton is a registered trademark of E.I.DuPont
2

Pressure Drop Curves


A – CV16-10-P-O-50
1 Cartridge only
B – CV16-10-P-O-25
Flow - L/min (21,8 cSt oil @ 49°C) C – CV16-10-P-O-15
10 20 30 40 50 60 D – CV16-10-P-O-5
9
110
Pressure Drop - bar
Pressure Drop - psi

90
6
70 A
50
B 3
30
C
D

2 4 6 8 10 12 14 16 18
Flow - USgpm (105 SUS oil @ 120°F)

G-12 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code CV16-10

CV16 – 10 (V) – P – (*) ** – *** – 00

1 2 3 4 5 6 7 8

1 Function 6Port size


CV16 – Check Valve 0 – Cartridge only
2 Size CODE PORT SIZE HOUSING NUMBER

10 – 10 Size Aluminum Aluminum Steel


Light duty Fatigue rated Fatigue rated
3 Seals 3B 3/8” BSPP 02–175462 – –
Blank – Buna-N 6T SAE 6 566151 – 02–175100
V – Viton® 8T SAE 8 – – 02–175101
4 Style 2G 1/4” BSPP – 876702 02–175102
P – Poppet 3G 3/8” BSPP – 876703 02–175103
6H SAE 6 – 876700 –
5 Valve housing material G
8H SAE 8 – 876701 –
Omit for cartridge only
See Section J for housing details.
A – Aluminum
S – Steel
7 Free flow cracking 8 Special Features
pressure 00 – None
5 – 0,34 bar (5 psi) (Only required if valve has
(Anticavitation) special features - omitted
15 – 1,03 bar (15 psi) if “00”)
25 – 1,70 bar (25 psi) SS - 316 Stainless Steel
50 – 3,40 bar (50 psi) external components

Dimensions 8,0 (0.31)


mm (inch) 25,4 (1.0) hex

Torque cartridge in housing


A - 47-54 Nm
0.875"–14 Thd.
(35-40 ft. lbs)
S - 68-75 Nm
(50-55 ft. lbs)
31,7
(1.25)
2

1
Ø 15,80 (0.622)
WARNING
The cavity should be machined to Aluminum housings can be used for
the 14,29 (0.562) maximum diameter pressures up to 210 bar (3000 psi)
and 36,00 (1.417) maximum depth Steel housings must be used for
(see cavity detail, page M-12). operating pressures above 210 bar
(3000 psi)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 G-13


CV11-12
Check valve

Description Operation
The CV11-12 is a poppet This valve remains closed time the poppet lifts off the
type, screw-in cartridge until the spring bias is seat and allows flow from
check valve. reached at port 1 at which port 1 to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
1 2 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Free flow cracking pressure @ 1 L/min (0.25 USgpm) 2.5 – 0,17 bar (2.5 psi)
5.0 – 0,35 bar (5.0 psi)
10 – 0,69 bar (10 psi)
Profile View 20 –1,38 bar (20 psi)
40 – 2,76 bar (40 psi)
80 – 5,50 bar (80 psi)
160 – 11,0 bar (160 psi)
Internal leakage, Port 2 to 1 5 drops / min. maximum @ 350 bar (5000 psi)
Hysteresis Less than 0,35 bar (5 psi)
Temperature range –40˚ to 120˚C (–40˚ to 248˚F)
Cavity C–12–2 or C–12–2U
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,24 kg (0.54 lb)
2 Seal kit 02–165889 Buna–N
02–165888 Viton®
Viton is a registered trademark of E.I.DuPont

1
Pressure Drop Curves
A – CV11-12-P-O-80
Cartridge only
B – CV11-12-P-O-20
Flow - L/min (21,8 cSt oil @ 49°C) C – CV11-12-P-O-2.5
20 40 60 80 100
300 18
Pressure Drop - bar
Pressure Drop - psi

250 16
14
200 12
150 10
A 8
100 6
B
50 4
C
2
0
0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120°F)

G-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code CV11-12

CV11 – 12 (V) – P – (*) *** (U) – ** – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port size


CV11 – Check valve 0 – Cartridge only
CODE PORT SIZE HOUSING NUMBER
2 Size
C-12-2U C-12-2 C-12-2U C-12-2
12 – 12 Size Aluminum Aluminum Steel Steel
Fatigue rated Fatigue rated Fatigue rated Fatigue rated
3 Seals
Blank – Buna-N 10T SAE 10 02–160641 02–160640 02–169817 02–169744
V – Viton® 12T SAE 12 02–160645 02–160644 02–169790 02–169782
4
4G 1/2” BSPP 02–161116 02–161118 02–172512 02–172062
Style
6G 3/4” BSPP 02–161115 02–161117 02–162922 02–169665
P – Poppet
See Section J for housing details.
5 Valve housing material G
7 Cavity 8
Cracking pressure 9 Special Features
Omit for cartridge only 00 – None
A – Aluminum Blank – Cavity without 2.5 – 0,17 bar (2.5 psi)
undercut 5.0 – 0,35 bar (5 psi) (Only required if valve has
S – Steel special features - omitted
U – Cavity with undercut 10 – 0,69 bar (10 psi)
20 – 1,38 bar (20 psi) if “00”)
40 – 2,75 bar (40 psi)
80 – 5,50 bar (80 psi)
160 – 11,0 bar (160 psi)

Dimensions
mm (inch) 1,6 (1.25) hex
18,9
Torque cartridge in housing (0.75)
A - 81-95 Nm
(60-70 ft. lbs) 1.062"–12 Thd.
S - 102-115 Nm
(75-85 ft. lbs)
44,7
(1.76)
Aluminum
housings can be 2
used for
pressures up to
210 bar (3000 psi)
Steel housings must be 1
used for operating Ø 23,75 (0.935)
pressures above 210 bar
(3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 G-15


CV6-10
Orifice check valve

7,95
(.313)
1" HEX

0.875"-14 Thd.

2 31,67
(1.247)
Description Operation
The CV6-10-P is a poppet This valve acts a restrictor
type, screw-in cartridge in the 2 to 1 direction and
1
check valve with bypass as a check valve it allows
Ø 15,8 (.622)
orifice. free flow from 1 to 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
1 2
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 76 L/min (20 USgpm)
Sectional View Free flow cracking pressure @1 L/min (0.25 USgpm) 003 – 0,21 bar (3 psi)
010 – 0,69 bar (10 psi)
020 –1,38 bar (20 psi)
035 –2,41 bar (35 psi)
040 – 2,76 bar (40 psi)
065 – 4,48 bar (65 psi)
100 – 6,90 bar (100 psi)
7,95 180 –12,40 bar (180 psi)
(.313) 210 –14,50 bar (210 psi)
Orifice size range
1" HEX 0.015 to 0.125” (0.381 - 3.175 mm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity 0.875"-14 Thd. C–10–2
Fluids 31,67 All general purpose hydraulic fluids such as
2 MIL–H–5606, SAE 10, SAE 20, etc.
(1.247)
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
1 Weight cartridge only 0,08 kg (0.17 lbs)
Seal kit Ø 15,8 (.622) 565803 Buna–N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

1 2
Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60 80
500
30
400
Pressure Drop - psi

Pressure Drop - bar

A - CV6 10*P 000 210 00 300


20
B - CV6 10*P 000 040 00 A
C - CV6 10*P 000 003 00 200
10
100
B
C
0
0 5 10 15 20
Flow - USgpm (105 SUS oil @ 120°F)
Port 1 to 2

G-20 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code CV6-10

CV6 10 * P * ** *** ** 00

1 2 3 4 5 6 7 8 9

1 Function 5 Valve housing material 6 Port size


CV6 - Check valve with 0 - No housing 00 - Cartridge only
bypass orifice A - Aluminum
S - Steel CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum Steel
7 Free flow cracking Light duty Fatigue rated Fatigue rated
10 - 10 Size
pressure 3B 3/8” BSPP 02-175462 – –
3 Seals 003 - 0,21 bar (3 psi) 6T SAE 6 566151 – 02-175100
N - Buna-N (Anti-cavitation)
8T SAE 8 – – 02-175101
V - Viton® 010 - 0,69 bar (10 psi)
(Anti-cavitation) 2G 1/4” BSPP – 876702 02-175102
4 Style 020 - 1,38 bar (20 psi) 3G 3/8” BSPP – 876703 02-175103
P - Poppet 035 - 2,41 bar (35 psi) 6H SAE 6 – 876700 –
040 - 2,76 bar (40 psi) G
065 - 4,48 bar (65 psi) 8H SAE 8 – 876701 –
100 - 6,90 bar (100 psi) See Section J for housing details.
180 - 12,4 bar (180 psi)
8 Orifice size 9 Special features
210 - 14,5 bar (210 psi)
Specify in thousandths 00 - None
of an inch (Only required if valve has
Ø - 0.125 max special features - omitted
Ø - 0.015 min if “00”)
SS - 316 Stainless Steel
external components

Dimensions
mm (inch) 8,0 (0.31)
25,4 (1.0) hex
Torque cartridge in housing
A - 47-54 Nm
(35-40 ft. lbs) 0.875"–14 Thd.
S - 68-70 Nm
(50-55 ft. lbs)
31,7
(1.25)
2

1
Ø 15,80 (0.622)

Aluminum housings can be used for


pressures up to 210 bar (3000 psi)
Steel housings must be used for operating
pressures above 210 bar (3000 psi)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 G-21


CV6-16
Orifice check valve
12,7
(.500)

1.5" HEX

1.312"-12 Thd.

44,58
(1.75)

Description 2 Operation
2 2
The CV6-16-P is a poppet This valve acts a restrictor
type, screw-in cartridge in the 2 to 1 direction and
check valve
1 with bypass as a check valve1 it allows 1
orifice. free flow from 1 to 2. Ø 28,53 (1.123)

Functional Symbol RATINGS AND SPECIFICATIONS

1 2 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 151 L/min (40 USgpm)
Sectional View Free flow cracking pressure @1 L/min (0.25 USgpm) 005 – 0,34 bar (3 psi)
020 –1,34 bar (2012,7
psi)
030 – 2,07 bar (30(psi)
.500)
050 – 3,45 bar (50 psi)
Orifice size range 1.5" HEX 0.015 - 0.125 inch (0.381 - 3.175 mm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids 1.312"-12 Thd.
All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code44, 58
18/16/13
(1.75)
Standard housing materials Aluminum
2 Weight cartridge only 0,26 kg (0.58 lbs)
2 2
Seal kit 565810 Buna–N
889609 Viton®
Viton is a registered trademark of E.I. DuPont
1 1 1
Ø 28,53 (1.123)

1 2 Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 40 80 120 160
125
8
100
Pressure Drop - bar
Pressure Drop - psi

6
A - CV6 16*P 0000 050 00 75
B - CV6 16*P 0000 020 00 A
4
C - CV6 16*P 0000 005 00 50
B
C
2
25

0 10 20 30 40
Flow - USgpm (105 SUS oil @ 120°F)
Port 1 to 2

G-22 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code CV6-16

CV6 16 * P * *** *** *** 00

1 2 3 4 5 6 7 8 9

1 Function 5 Block material 6 Port size


CV6 - Check valve with 0 - No housing 000 - Cartridge only
bypass orifice A - Aluminum
CODE PORT SIZE HOUSING NUMBER
2 Size 7 Free flow cracking Aluminum Aluminum
16 - 16 Size pressure Light duty Fatigue rated
005 - 0,21 bar (5 psi) 6B 3/4” BSPP 02-175463 –
3 Seals (Anti-cavitation) 12T SAE 12 566149 –
N - Buna-N 020 - 1,34 bar (20 psi)
4G 1/2” BSPP – 876716
V - Viton® 030 - 2,07 bar (30 psi)
040 - 2,76 bar (40 psi) 6G 3/4” BSPP – 876718
4 Style 050 - 3,45 bar (50 psi) 10H SAE 10 – 876717
P - Poppet 100 - 6,90 bar (100 psi) 12H SAE 12 – 566113
G
See Section J for housing details.

8 Orifice size 9 Special features


Specify in thousandths 00 - None
of an inch (Only required if valve has
Ø - 0.125 max special features - omitted
Ø - 0.015 min if “00”)

Dimensions 12,7
mm (inch) (.500)
1.5" HEX
Torque cartridge in
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312"-12 Thd.

44,58
(1.75)

2 2

1 1
Ø 28,53 (1.123)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 G-23


RV3-10
Relief Valve
Poppet, differential area

Description Operation
The RV3-10 is a direct This valve remains closed has been reached at port 2.
acting, differential area, from port 2 to port 1 until The poppet is unseated and
poppet type, screw-in the predetermined setting allows flow out of port 1.
cartridge relief valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 250 bar (3600 psi)
2 1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 76 L/min (20 USgpm)
Internal leakage 5 drops/min @ 85% of Pressure Setting
Cavity C-10–2
Sectional View Standard housing materials Aluminum or steel
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,22 kg. (0.48 lbs.)
Seal kits – RV3 565803 Buna–N
566086 Viton®
– RV3A (with double backup rings) 565806 Buna–N
889627 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Override Curves


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60
Tank pressure = 0
4000 280

Inlet pressure - bar


Inlet pressure - psi

2
3000 210
A
1 A - 36 spring
B - 18 spring 2000 140

C - 6 spring B
1000 70

C
0 0
0 5 10 15 20
Flow - USgpm (105 SUS oil @ 120°F)

E-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code RV3-10

RV3 (A) – 10 (V) – * – (*) – ** – ** / ** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 7 Port size 8 Cracking pressure range


RV3 - Relief valve 0 - Cartridge only 3- 3,5-20 bar
CODE PORT SIZE HOUSING NUMBER (50-300 psi)
2 Cage seals 6- 7-41 bar
Aluminum Aluminum Steel
Blank - Single backup ring Light duty Fatigue rated Fatigue rated (100-600 psi)
A - 1/2 thickness backup 3B 3/8” BSPP 02–175462 – – 9- 14-62 bar
ring on each side of O-ring (200-900 psi)
(for cross port relief 2G 1/4” BSPP – 876702 02–175102 18 - 20-124 bar
applications) 3G 3/8” BSPP – 876703 02–175103 (300-1800 psi)
6H SAE 6 – 876700 – 36 - 41-250 bar
3 Size 8H SAE 8 – 876701 – (600-3600 psi) E
10 - 10 Size 6T SAE 6 566151 – 02–175100 9 Setting pressure
8T SAE 8 – – 02–175101
4 Seals Within ranges in 8
H10H SAE 10* – 4997062-001 – Blank - Normal factory
Blank - Buna–N
V - Viton® 2K10H SAE 10** – 4997060-001 – setting at approximate
* Bolt on, dual cross over relief valve package for Eaton H or T series motors mid-range. User requested
5 ** Bolt on, dual cross over relief valve package for Eaton 2000 series motors settings in 3,45 bar (50 psi)
Adjustment steps, coded as in the
C - Cap (Note: Two cartridges are installed in this special housing, both are set to the same crack
following examples:
F - Factory set pressure specified in model code position 9, maximum allowed setting is 210 bar (3000
A option and aluminum housing.)
psi), only available with RV3A 10 - 70 bar (1000 psi)
I - Internal 10.5 - 72,4 bar (1050 psi)
K - Knob See section J for housing details.
S - Screw
Special features
6 Valve housing 00 - None
material (Only required if valve has
Blank - Aluminum special features, omitted
S - Steel if “00”)
SS - 316 Stainless Steel
external components
“C”Adjustment 19,1 (0.75) hex

Dimensions “I”Adjustment “S”Adjustment “K”Adjustment


mm (inch) Ø 38,1 (1.50)
“F”Adjustment
Torque cartridge in housing 80,0
A - 47-54 Nm (35-40 ft. lbs) (3.13)
S - 68-75 Nm (50-55 ft. lbs)

53,0
(2.08)
25,4 (1.0) hex

Aluminum
housings can
0.875"-14 Thd. • be used for
31,8 pressures up
(1.25) to 210 bar (3000 psi).
2 Steel housings must be
used for operating pres-
1 sures above 210 bar
Ø 15,82 (0.623) (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-15


Flow Controls
Section introduction

This section gives basic • Flow divider/combiners For example: FDC*1-10-*–66 This valve is used in place
specifications for the com- (FDC1 and FDC11) with will divide an incoming flow of a standard flow divider-
plete line of Vickers thread- flows rated to 568 L/min of 45 L/min (12 USgpm) combiner in systems where
ed cartridge flow control (150 USgpm). equally out each port with hydraulic motors are used
valves. Its purpose is to • Posi-traction valves an accuracy of 10% each as drive wheels on each
provide a quick, convenient (FDC13) with flows rated side. With 45 L/min (12 side of the machine. The
reference tool when choos- to 567 L/min (150 USgpm) in at “3” port, flow positive traction valve acts
ing Vickers cartridge valves USgpm) out port “4” can be 22 much like a standard flow
or designing a system L/min (6 USgpm) 4,5 L/min divider-combiner as the
using these components. • Operating pressures to (1.2 USgpm) while flow at vehicle travels in a straight
350 bar (5000 psi). port “2” is 22,7 L/min (6 line. Equal amounts of flow
Valve Features and Here are some of the bene- USgpm) 4,5 L/min (1.2 go to each “C” port. As the
Benefits fits of Vickers flow USgpm). vehicle turns a corner, a
Eaton offers a complete controls: The combining accuracy is standard flow divider will
range of Vickers flow con- the same with incoming maintain equal flow to each
• All operating parts are
trols cartridge valves, with a flow at port “4” and “2” drive motor. On a turn, it is
hardened steel, ground
variety of features, including: and flow out port “3” of 45 necessary for the outer
and honed for long life
and low leakage. L/min (12 USgpm). Inlet wheel to turn faster than F
• Products in this catalog the inner wheel. A standard
have been Fatigue tested flow at port “4” will be 22
• Designed for maximum flow divider-combiner will
to one million cycles L/min (6 USgpm) 4,5 L/min
flexibility and minimal provide equal flow to each
at 132% or 10 million (1.2 USgpm). Inlet flow at
space requirements. motor causing the drive
cycles at 115% of rated port “2” will be 22 L/min (6
• All exposed cartridge sur- USgpm) 4,5 L/min (1.2 motors to skid. The positive
pressure. traction valve solves this
faces are zinc dichromate USgpm).
• Non-adjustable, pressure plated to resist corrosion. problem by allowing the
compensated, flow regu- Flow division or combining one motor to turn faster
Steel housings are avail-
lator for flows to 227 will be maintained even if than the other.
able for cartridges rated
L/min (60 USgpm). unequal loads are placed on
to 350 bar (5000 psi) This operates in a similar
ports “4” and “2”.
• Adjustable, pressure application pressures. way as a mechanical differ-
compensated, flow regu- A special feature of the ential on an automobile. In
• All aluminum manifolds
lator for flows to 114 FDC*1–** is that it provides a turn, the inside drive
are gold anodized to
L/min (30 USgpm). rephase flow to either port motor is restricted and
resist corrosion.
2 or port 4 when one of the builds up pressure, while
• Fixed and adjustable pri- • Reliable, economical and two is blocked. This feature the outside drive motor is
ority bypass type flow compact. is useful in hydraulic circuits without restriction. Under
regulator for regulated that require cylinders to conditions of high differen-
• Low leakage.
flows to 114 L/min (30 move at the same time. If tial pressure, the positive
USgpm). • Variety of adjustment one cylinder bottoms out
options. traction valve passes extra
• Adjustable flow control first, the opposite cylinder is flow to the least restricted
without free reverse flow • Adjustments designed provided with “rephase” motor to prevent skidding.
check with flows rated to not to go spring solid at flow to allow the cylinder to Under straight running con-
114 L/min (30 gpm). “full in” position or to bottom and start the cylin- ditions the differential pres-
allow the adjustment to ders together for movement sure is low and equal
• Adjustable flow control in the opposite direction.
be removed when amounts of flow are provid-
with free reverse flow
backed out. ed to each drive motor.
check with flows rated to
Notable are the two styles FDC3/FDC13
45 L/min (12 gpm).
of flow divider/combiner: The FDC*3 is a cartridge WARNING
• Needle valves with flows
type positive traction valve For pressure over
rated to 265 L/min (70 •
FDC1/FDC11 that divides and combines 210 bar (3000 psi)
USgpm).
The FDC*1 is a cartridge flow, regardless of system use steel housing.
• Velocity fuses with flows load or pressure, propor-
type hydraulic flow divider-
rated to 227 L/min (60 tionally per specified flow
combiner valve. It divides
USgpm). division.
and combines flow, regard-
less of system load or pres-
sure, proportionally per
specified flow division.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-3


NV1-10
Needle valve

Description Operation
The NV1–10 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in either wise.
direction, from full flow to
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Functional Symbol Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
2 Cavity C–10–2
1 F
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg. (0.24 lbs.)
Seal Kits 565806 Buna–N
889627 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Pressure Drop Curve Fully open port 1 to port 2


Cartridge only or port 2 to port 1

Flow - L/min (21,8 cSt oil @ 49°C)


5 10 15 20 25 30 35 40 45

70 5
Pressure drop - bar
Pressure drop - psi

60 4
50
3
2 40
30 2
1 20
1
10
0 0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-47


Model Code NV1-10

NV1 – 10 (V) – * – **– 00

1 2 3 4 5 6

1 Function 5 Port size 6 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


(Only required if valve has
2 CODE PORT SIZE HOUSING NUMBER
Size special features, omitted
Aluminum Aluminum if “00”.)
10 – 10 Size Light duty Fatigue rated
3 Seals 3B 3/8” BSPP 02–175462 –
Blank– Buna-N 6T SAE 6 566151 –
V – Viton® 2G 1/4” BSPP – 876702
4 3G 3/8” BSPP – 876703
Style
6H SAE 6 – 876700
K – Knob (black)
R – Knob (red) 3G SAE 8 – 876701
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
47–54 Nm (35–40 ft.lbs)

Ø42,0
(1.65)

43,0
(1.69)

25,4 (1.00) hex

0.875" -14 Thd.


31,7
(1.25) 2

1
Ø15,80 (0.622)

F-48 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


FCV11-12
Flow control valve

Description Operation
The FCV11–12 is a direct This valve is non-pressure from full flow to tight shut
acting, adjustable needle compensated. Flow is con- off, by turning the adjust-
valve. trolled in either direction, ment feature clockwise.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure 350 bar (5000 psi) Port “1” to “2”
210 bar (3000 psi) Port “1” to “2”
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Internal leakage less than 5 drops / min. max. @210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-2 or C-12-2U F
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
1 Weight cartridge only 0,24 kg (0.54 lb.)
Seal kit 02–165889 Buna–N
02–165888 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View
Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60 80 100
A – Cartridge with C-12-2 90 6,21
valve body, full open 80 5,52
B – Cartridge with C-12-2U 70 4,83

Pressure drop - bar


Pressure drop - psi

valve body, full open A


C – Cartridge only, full 60 4,14
open B
50 3,45
40 C
2,5
2 30 2,0
20 1,0

1 10 0,5
0
0 5 10 15 20 25 30

Flow - USgpm (105 SUS @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-55


Model Code FCV11-12

FCV11 – 12 (V) – S – *– ***– (U) – NV – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port size

FCV11 – Flow control valve 0 – Cartridge only


CODE PORT SIZE HOUSING NUMBER
2 Size
C-12-2U C-12-2 C-12-2U C-12-2
12 – 12 Size Aluminum Aluminum Steel Steel
Fatigue rated Fatigue rated Fatigue rated Fatigue rated
3 Seals
10T(U) SAE 10 02–160641 02–160640 02–169817 02–169744
Blank– Buna-N
12T(U) SAE 12 02–160645 02–160644 02v169790 02–169782
V – Viton®
4G(U) 1/2” BSPP 02–161116 02–161118 02–172512 02–172062
4 Adjustment 6G(U) 3/4” BSPP 02–161115 02–161117 02–162922 02–169665
S – Screw See section J for housing details.
K – Knob Note: C-12-2U housings have undercut for improved flow.

5 Valve housing material


Blank – No body 7 8 Valve type 9
S – Steel Cavity Special features
A – Aluminum Blank – Cavity without NV – Needle Valve 00 – None
undercut (Adjustable) (Only required if valve has
U – Cavity with undercut special features, omitted
Dimensions if “00”.) housings can be
mm (inch)

Torque cartridge in housing


A – 81–95 Nm (60–70 ft.lbs) "S" Adjustment
S – 102–115 Nm (75–85 ft.lbs) 3,2 (0.12) hex
40,0
(1.60)

31,8 (1.25) hex

1.063"–12
Thd.
44,6
(1.80)

2
Aluminum hous-
ings can be used
• for pressures up to
1 210 bar (3000 psi)
Ø23,75 (0.935) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

F-56 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


FCV6-16
Flow control valve

Description Operation
The FCV6-16 is a non-pres- This valve allows flow counterclockwise. In the full
sure compensated, between ports 1 and 2 clockwise position this valve
adjustable, flow restrictor. through an increasing provides tight shut-off.
variable orifice when the
Functional Symbol adjustment is turned

2 RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 208 L/min (55 USgpm)
Internal leakage Port 2 to 1; <5 drops/min
maximum @ 210 bar (3000 psi)
1 F
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,37 kg (0.81 lbs.)
Seal kits 889631 Buna-N
889635 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Full open port 1 to port 2


Cartridge only or port 2 to port 1

Flow - L/min (21,8 cSt oil @ 49°C)


0 40 80 120 160 200
100 7
90
2 6
Pressure drop - bar
Pressure drop - psi

80
70 5
1 60 4
50
3
40
30 2
20
1
10
0
0 10 20 30 40 50 60
Flow - USgpm (105 SUS @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-57


Model Code FCV6-16

FCV6 – 16 (V) – * – *** – NV– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Controlled flow option

FCV6 – Flow control valve 0 – Cartridge only NV – Needle valve


2 Size CODE PORT SIZE HOUSING NUMBER 7 Special features

16 – 16 Size Aluminum Aluminum 00 – None


Light duty Fatigue rated (Only required if valve has
3 Seals special features, omitted
6B 3/4” BSPP 02–175463 –
Blank– Buna-N 12T SAE 12 566149 – if “00”.)
V – Viton®
4G 1/2” BSPP – 876716
4 Style 6G 3/4” BSPP – 876718
C – Cap 10H SAE 10 – 876717
K – Knob 12H SAE 12 – 566113
S – Screw See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft.lbs)
"S" Adjustment
4,8 (0.18) hex "C" Adjustment
"K" Adjustment 19,1 (0.75) hex
Ø38,1 (1.50)

59,0
51,0 51,0 (2.32)
(2.00) (2.00)
38,1 (1.5) hex

1.312" -12 Thd.


44,7
(1.76)
2

1
Ø28,55 (1.124)

F-58 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


NV1-16
Needle valve

Description Operation
The NV1–16 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical Typical application pressure (all ports) 210 bar (3000 psi)
direction Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
of flow
Rated flow 151 L/min (40 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F) F
1 Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,34 kg. (0.76 lbs.)
Seal kits 565810 Buna–N
889609 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Full open port 2 to port 1


Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C)


0 20 40 60 80 100 120 140

2
70 5

1 60
4
Pressure drop - bar
Pressure drop - psi

50
Application Note 3
40
The valve is not intended
for use at low flows, may 30 2
chatter below 10 L/min
(2.5 gpm) 20
1
10

0
0 10 20 30 40
Flow - USgpm (105 SUS oil @ 20°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-49


Model Code NV1-16

NV1 – 16 (V) – K – ***– 00

1 2 3 4 5 6

1 Function 5 Port size 6 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


CODE PORT SIZE HOUSING NUMBER (Only required if valve has
2 Size special features, omitted
Aluminum Aluminum
16 – 16 Size Light duty Fatigue rated
if “00”.)

3 Seals 6B 3/4” BSPP 02–175463 –


Blank– Buna-N 12T SAE 12 566149 –
V – Viton® 4G 1/2” BSPP – 876716
6G 3/4” BSPP – 876718
4 Style
10H SAE 10 – 876717
K – Knob (black)
R – Knob (red) 12G SAE 12 – 566113
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
108–122 Nm (80–90 ft.lbs)

Ø61,0
(2.40)

61,0
(2.40)

38,1 (1.50) hex


1.312"?-12 Thd.

44,4
(1.75) 2

1
Ø28,55 (1.124)

F-50 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


NV1-20
Needle valve

Description Operation
The NV1–20 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Typical
direction Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
of flow Rated flow 265 L/min (70 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–20–2
F
1
Fluids All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum
Weight cartridge only 0,59 kg. (1.3 lbs.)
Seal kits 889615 Buna-N
889619 Viton ®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Full open port 2 to port 1.


Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C)


0 40 80 120 160 200 240
70 5
2
60
4
1 50
Pressure drop - bar
Pressure drop - psi

40 3

Application Note 30 2
The valve is not intended
20
for use at low flows, may
1
chatter below 10 L/min 10
(2.5 gpm)
0 0
0 10 20 30 40 50 60 70
Flow - USgpm (105 SUS oil @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-51


Model Code NV1-20

NV1 – 20 (V) – * – ***– 00

1 2 3 4 5 6

1 Function 5 Port size 6 Special features

NV1 – Needle valve 0 – Cartridge only 00 – None


CODE PORT SIZE HOUSING NUMBER (Only required if valve has
2 Size special features, omitted
Aluminum Aluminum
20 – 20 Size Light duty Fatigue rated if “00”.)

3 Seals 8B 1” BSPP 02–175464 –


Blank– Buna-N 16T SAE 16 566409 –
V – Viton® 6G 3/4” BSPP – 876732
8G 1” BSPP – 876734
4 Style
12H SAE 12 – 876733
K – Knob (black)
16H SAE 16 – 876735
R – Knob (red)
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum housing
128–155 Nm (95–115 ft.lbs)

Ø61,0
(2.40)

62,0
(2.44)
47,6 (1.87) hex

1.625 "-12 Thd.


57,1
(2.25)
2

1
Ø36,47 (1.436)

F-52 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


MRV2-10
Manual rotary flow
control valve

Description Operation
The MRV2-10 is a 2-way, This valve will increase or rotary adjustment.
2 position, manual decrease flow by changing Recommended flow path
semi-rotary screw-in flow the variable orifice with the is 2 to 1.
restrictor valve. RATINGS AND SPECIFICATIONS
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 05 – 0-18,9 L/min (0–5 USgpm)
10 – 0-37,8 L/min (0–10 USgpm)
15 – 0-56,7 L/min (0–15 USgpm)
Internal leakage 164 cm3 /min. (10 in3/min)
maximum 210 bar (3000 psi)
Functional Symbol Temperature range -40° to 120°C (-40° to 248°F)
Manual operators B – Ball lever (friction lock)*
E – Ball lever (10 position detent)*
2 1 D – Lever (10 position detent)* F
L – Lever (friction lock)*
*Light duty housings only K – Knob (non-locking)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 561810 Buna-N
Sectional View 889609 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Cartridge only
@ 5,5 bar (80 psi)
pressure drop
Flow-L/min(21,8cStoil@49°C)
10 20 30 40 50 60
Rated flow 9
A B
2 C
(See model code 8
position 6) 7
Knob lever position

A - 05
1 6
B - 10
5
C - 15
4
3
2
1
0
0 2 4 6 8 10 12 14
Flow - USgpm (105 SUS oil @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-41


Model Code MRV2-10

MRV2 – 10 (V) – * – ** – **– 00

1 2 3 4 5 6 7

1Function 4 Adjustment 5 Port size rt size


MRV2 – Manual rotary valve 0 – No operator 0 – Cartridge only 0 – Cartridge only
B – Ball lever CODE PORT SIZE HOUSING NUMBER
2 Size (friction lock)*
Aluminum Aluminum
10 – 10 Size E – Ball lever Light duty Fatigue rated
(10 position detent)*
3 Seals D – Lever 3B 3/8” BSPP 02-175462 –
Blank– Buna-N (10 position detent)* 6T SAE 6 566151 –
V – Viton® L – Lever (friction lock)* 2G 1/4” BSPP – 876702
K – Knob (non-locking)
* Light duty housings only.
3G 3/8” BSPP – 876703
6H SAE 6 – 876700
8H SAE 8 – 876701
See section J for housing details.

6 Max flow ranges 7 Special features


(nominal) 00 – None
05 – 0–18,9 L/min (0–5 USgpm) (Only required if valve has
10 – 0–37,8 L/min (0–10 special features, omitted
Dimensions if “00”.)
USgpm)
mm (inch) 15 – 0–56,7 L/min (0–15 USgpm) SS – 316 Stainless Steel
Torque cartridge in aluminum external components
housing 47–54 Nm (35–40 ft.lbs)

MRV2-10-K Knob Operated MRV2-10-B/E Models MRV2-10-D/L Models


Arrow can be re-located by
Ø25,4 (1.00) 41,0
slacking the plate. Re-tighten nut. (1.60)

41,0 38,1
(1.60) 58,0
(1.50) X (2.28)
X X X

42,0 42,0
(1.65) (1.65)

MRV2-10-E/D Models MRV2-10-B/L Models


37,0
(1.45) 17,0 Locating
(0.67) Locating pin hole
25,4 (1.00) hex pin hole

0.875"-14 Thd.?
31,7
(1.25) 2
Ø3,45-3,50 0
(#29 or 0.136+0.002)
1 x 4,76 (0.187)
Ø15,80 (0.622) in mating housing

F-42 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


MRV2-16
Manual rotary valve

Description Operation
The MRV2-16 is a 2-way, 2 This valve will increase or Recommended flow path
position, manual semi- decrease flow by changing is 2 to 1.
rotary screw-in flow restric- the variable orifice with the
tor valve. rotary adjustment.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 10 – 0-37,8 L/min (0–10 USgpm) 30 – 0-113,5 L/min (0–30 USgpm)
15 – 0-56,7 L/min (0–15 USgpm) 35 – 0-132,4 L/min (0–35 USgpm)
20 – 0-75,7 L/min (0–20 USgpm) 40 – 0-151,4 L/min (0–40 USgpm)
Functional Symbol 25 – 0-94,6 L/min (0–25 USgpm) 45 – 0-170,3 L/min (0–45 USgpm)
Internal leakage 82 cm3 /min. (5 in3 /min
maximum 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
F
2 1
Manual operators D – Lever (10 position detent)
L – Lever (friction lock)
K – Knob (non-locking)
Light duty housings only
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Sectional View Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 565810 Buna-N
889609 Viton®®
Viton is a registered trademark of E.I. DuPont
Pressure Drop Curve Rated flow
Cartridge only (See model code position 6)
A - 10 E - 30
@ 5,5 bar (80 psi) B - 15 F - 35
pressure drop C - 20 G - 40
Flow - L/min (21,8 cSt oil @ 49°C) D - 25 H - 45

20 40 60 80 100 120 140 160 180


2 9
A B C D E F G H
8
7
Knob lever position

1
6
5
4
3
2
1

0 4 8 12 16 20 24 28 32 36 40 44
Flow - USgpm (105 SUS oil @ 20°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-43


Model Code MRV2-16

MRV2 – 16 (V) – * – *** – **– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Max flow ranges


MRV2 – Manual rotary valve 0 – Cartridge only (nominal)
CODE PORT SIZE HOUSING NUMBER 10 – 0-37,8 L/min
2 Size (0-10 USgpm)
Aluminum Aluminum
16 – 16 Size Light duty Fatigue rated
15 – 0-56,7 L/min
(0-15 USgpm)
3 Seals 6B 3/4” BSPP 02-175463 – 20 – 0-75,7 L/min
Blank– Buna-N 12T SAE 12 566149 – (0-20 USgpm)
V – Viton® 4G 1/2” BSPP – 876716 25 – 0-94,6 L/min
(0-25 USgpm)
6G 3/4” BSPP – 876718
4 Adjustment 30 – 0-113,5 L/min
10H SAE 10 – 876717 (0-30 USgpm)
0 – No operator
D – Lever (10 position 12H SAE 12 – 566113 35 – 0-132,4 L/min
detent)* See section J for housing details. (0-35 USgpm)
L – Lever (friction lock)* 40 – 0-151,4 L/min
K – Knob (non-locking) (0-40 USgpm)
* Light duty housings only. 45 – 0-170,3 L/min
(0-45 USgpm)
7 Special features
Dimensions 00 – None
mm (inch) (Only required if valve has
special features, omitted
Torque cartridge in aluminum
if “00”.)
housing 108–122 Nm (80–90 ft.lbs)

MRV2-16-K Knob Operated MRV2-16-D/L Models


58,0
(2.28)

76,0
X X (3.00)

6,0
(2.40)

MRV2-16-D Models MRV2-16-L Models


46,0 24,8 Locating
(1.81) Locating pin hole
(0.98) pin hole
38,1 (1.50) hex
1.312"-12 Thd.
44,4
(1.75) 2 Ø3,45-3,50
0
(#29 or 0.136+ 0.002)
1 x 4,76 (0.187)
Ø28,55 (1.124) in mating housing

F-44 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


FR5-8
Flow regulator, fixed

Description Operation Operation


The FR5–8 is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure stant flow from port 1 to port 2 to port 1 is at the value
compensated, restrictive port 2 based on 5.5 bar of the fixed orifice and is non-
flow regulator screw-in (80 psid) regardless of pres- pressure compensated.
cartridge valve. sure changes downstream on

Functional Symbols RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2
Typical application pressure (all ports) 350 bar (5000 psi) steel housing
210 bar (3000 psi) aluminum housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated flow 10 L/min (2.5 USgpm)
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) 20% @ 210 bar (3000 psi)
0,4–1,9 L/min (0.1–0.49 USgpm) 40% @ 350 bar (5000 psi)
1
1,9 – 5,7 L/min (0.5–1.49 USgpm) 15%
5,7–10 L/min (1.5–2.5 USgpm) 10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Sectional View
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–8–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,05 kg (0.12 lbs.)
2
Seal kits 02–165875 Buna-N
02–165877 Viton®
Viton is a registered trademark of E.I. DuPont
1

Typical Flow Regulation


Pressure - bar
Cartridge only 0 70 140 210 280 350
3.0
10
2.5
(21,8 cSt oil @ 49°C)

A
(105 SUS oil @ 120°F)

Flow - L/min

8
Flow - USgpm

2.0

6
1.5

4
A – 9,5 L/min (2.5 USgpm) 1.0
B
B – 1,9 L/min (0.5 USgpm) 0.5 2
C – 0,38 L/min (0.1 USgpm) C
0
0 1000 2000 3000 4000 5000
Pressure - psi

F-4 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FR5-8

FR 5 – 8 (V) – F – (*) ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate,

FR5 – Flow regulator 0 – Cartridge only nominal


(Specify in USgpm)
2 Size CODE PORT SIZE HOUSING NUMBER
Range 0,4–9,5 L/min
8 – 8 Size Aluminum Steel (0.1–2.5 USgpm)
Fatigue rated Fatigue rated
3 Seals Example:
4T SAE 4 02–160730 02–160736
Blank – Buna-N 6T SAE 6 02–160731 02–160737 0.5– 1,9 L/min (0.5 USgpm) F
V – Viton®
8T SAE 8 02–160732 02–160738 8 Special features
4 Adjustment 2G 1/4” BSPP 02–160727 02–160733 00 – None
F – Fixed orifice 3G 3/8” BSPP 02–160728 02–160734 (Only required if valve has
See section J for housing details. special features, omitted
5 Valve housing material if “00”.)
Omit for cartridge only SS – 316 Stainless Steel
S – Steel external components
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in steel or 8,6


aluminum housing to (0.34) 22,1 (.870) hex
34-41 Nm (25-30 ft.lbs)
0.750" -16 Thd.
27,8
(1.09)
2

1
Ø12,62 (0.497) Aluminum hous-
ings can be used
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-5


FR1-16
Flow regulator, fixed

Description Operation
The FR1-16-F is a This valve maintains a con- port 2. Reverse flow from
fixed orifice, pressure com- stant flow from port 1 to port 2 to port 1 is at the
pensated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,33 kg (0.72 lbs.)
Seal kits 565810 Buna-N
880609 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 114 L/min (30.0 USgpm)


Cartridge only B – 60 L/min (15.0 USgpm)
C – 9,5 L/min (2.5 USgpm)

2
Pressure - bar
0 70 140 210
35 140
1 A
(21,8 cSt oil @ 49°C)
(105 SUS oil @ 120°F)

30 120
Flow -L/min
Flow - USgpm

25 100
20 80
15 B 60
10 40
C 20
5
0 0
0 1000 2000 3000
Pressure - psi

F-8 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FR1-16

FR 1 – 16 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR1 – Flow regulator 0 – Cartridge only nominal


(Specify in USgpm)
2 Size CODE PORT SIZE HOUSING NUMBER
Range 1,9–114 L/min
16 – 16 Size Aluminum Aluminum (0.5–30 USgpm)
Light duty Fatigue rated
3 Seals 6B 7 Special features
3/4” BSPP 02–175463 –
Blank– Buna-N 12T SAE 12 566149 – 00 – None F
V – Viton® 4G 1/2” BSPP – 876716 (Only required if valve has
special features, omitted
4 Adjustment 6G 3/4” BSPP – 876718 if “00”.)
F – Fixed orifice 10H SAE 10 – 876717
12H SAE 12 – 566113
See section J for housing details.

Dimensions
mm (inch)
28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing to
108-122 Nm (80-90 ft.lbs)
1.312" -12 Thd.

44,4
(1.75) 2

1
Ø28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-9


FR1-20
Flow regulator, fixed

Description Operation
The FR1-20-F is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure compen- stant flow from port 1 to port 2 to port 1 is at the
sated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 227 L/min (60 USgpm)
2 Flow regulation accuracy 3,8–18,5 L/min (1–4.9 USgpm) ±15%
19–227 L/min (5–60 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–20–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,82 kg (1.8 lbs.)
Seal kits 889615 Buna-N
889619 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 227 L/min (60.0 USgpm)


Cartridge only B – 114 L/min (30.0 USgpm)
C – 38 L/min (10.0 USgpm)

Pressure - bar
2 0 70 140 210
70 280
(21,8 cSt oil @ 49°C)
(105 SUS oil @ 120°F)

60 A 240
Flow - L/min
Flow - USgpm

1 50 200
40 160
B
30 120
20 C 80
10 40
0 0
0 1000 2000 3000
Pressure - psi

F-10 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FR1-20

FR 1 – 20 (V) – F – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR1 – Flow regulator 0 – Cartridge only (Specify in USgpm)


Range 3,8 – 227 L/min
2 Size CODE PORT SIZE HOUSING NUMBER (0.1 – 60 USgpm)
20 – 20 Size Aluminum Aluminum
Light duty Fatigue rated 7 Special features
3 Seals 8B 1” BSPP 02–175464 – 00 – None
Blank– Buna-N 16T SAE 16 566409 – (Only required if valve has F
V – Viton® special features, omitted
6G 3/4” BSPP – 876732
if “00”.)
4 Adjustment 8G 1” BSPP – 876734
F – Fixed orifice 12H SAE 12 – 876733
16H SAE 16 – 876735
See section J for housing details.

Dimensions
mm (inch)
38,1 47,2 (1.87) hex
Torque cartridge in
aluminum housing to (1.50)
128-155 Nm (95-115 ft.lbs)
1.625" -12 Thd.

57,1
2
(2.25)

Ø36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-11


FR2-16
Flow regulator, adjustable

Description Operation
The FR2-16 is a limited This valve maintains a con- stream on port 2. Reverse
range adjustable*, pressure stant flow from port 1 to flow from port 2 to port 1 is
compensated, screw-in port 2 based on the setting at the value of the fixed ori-
flow regulator cartridge adjustment, regardless of fice and is non-pressure
valve. pressure changes down compensated.
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,71 kg (1.57 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – 114 L/min (30.0


Cartridge only USgpm)
B – 38 L/min (10.0 USgpm
C – 9,5 L/min (2.5 USgpm)
Pressure drop - bar

0 35 70 100 140 175 210


40 150
(105 SUS oil @ 120°F)

A
(21,8 cSt oil @ 49°C)

120
Flow - USgpm

30
Flow - L/min

90
20
B 60
10
30
C
2
0 0
0 500 1000 1500 2000 2500 3000
1 Pressure drop - psi

F-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FR2-16

FR 2 – 16 (V) – * – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

FR2 – Flow regulator 0 – Cartridge only (Specify in USgpm)


Range 1,9–114 L/min
2 Size CODE PORT SIZE HOUSING NUMBER
(0.5–30 USgpm)
16 – 16 Size Aluminum Aluminum
Light duty Fatigue rated 7 Special features
3 Seals 6B 3/4” BSPP 02–175463 – 00 – None
Blank– Buna-N 12T SAE 12 566149 – (Only required if valve has F
V – Viton® 4G 1/2” BSPP – 876716 special features, omitted
if “00”.)
4 Adjustment 6G 3/4” BSPP – 876718 SS - 316 Stainless Steel
K – Knob 10H SAE 10 – 876717 external components
S – Screw 12H SAE 12 – 876713
C – Cap See section J for housing details.
Y – Knob (Stainless)

Dimensions "S" Adjustment


mm (inch) 9,6 (0.37) hex
Torque cartridge in "C" Adjustment "K" Adjustment
aluminum housing to 19,1 (0.75) hex Ø50,8 (2.00)
108-122 Nm (80-90 ft.lbs)

107,2 104,0
(4.22) (4.09)

38,1 (1.50) hex

1.312 " -12 Thd.


44,5
2 (1.75)

1
Ø28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-15


FAR1-10
Flow regulator, pressure
compensated, fully
adjustable

Description Operation
The FAR1–10 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor, screw-in cartridge valve sure changes upstream of regulated flow base within and counter- clockwise to
with free reverse flow. port 1, or downstream of the adjusting range from 1 increase the flow. This valve
port 2. 13.8 bar (200 psi) to 38 lpm (0.25 to 10 allows free reverse flow
Functional Symbol from port 2 to port 1.
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 5–350 bar (75–5000 psi) steel housing
Min. pressure differential across valve 14 bar (200 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 1–38 L/min (.25–10 USgpm)
Flow regulation accuracy 4–38 L/min (1–10 USgpm) ±10%
1 1–4 L/min (0.25–1 USgpm) ±20%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Sectional View
Reverse check crack pressure 1.7 bar (25 psi)
Leakage at shutoff position 0.4 L/min (24.4 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,02 kg (0.44 lbs.)
“K” 0,23 kg (0.51 lbs.)
“H” 0,26 kg (0.59 lbs.)
Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont

2
Typical Flow Regulation
Cartridge only

1
PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION
Flow - L/min (21,8 cSt oil @ 49ºC) Pressure differential across valve in bar
8 16 24 32 40 70 140 210 280 350
200 12
40
(105 SUS oil @ 120°F)

12
(21,8 cSt oil @ 49°C)

10
Pressure drop - bar
Pressure drop - psi

150
Flow - USgpm

32
Flow -L/min

8
8
100 6 24

4 16
4
50
2 8

0 2 4 6 8 10 12 0 1000 2000 3000 4000 5000


Flow - USgpm (105 SUS oil @ 120°F) Pressure differential across valve in psi

F-16 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FAR1-10

FAR1 – 10 (V) – * – * – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate,

FAR1 – Fully adjustable, 0 – Cartridge only Blank – Normal factory


pressure compensated flow setting at 5 USgpm
regulator with reverse flow CODE PORT SIZE HOUSING NUMBER User requested setting
check Aluminum Aluminum Steel within .25–10 US gpm
Light duty Fatigue rated Fatigue rated (1-–38 L/min.)
2 Size 3B 3/8” BSPP 02–175462 – – 8 Special features
10 – 10 Size
2G 1/4” BSPP – 876702 02-175102 F
00 – None
3 Seals 3G 3/8” BSPP – 876703 02-175103 (Only required if valve has
Blank– Buna-N 6H SAE 6 – 876700 – special features, omitted
V – Viton® 8H SAE 8 – 876701 – if “00”.)

4 6T SAE 6 566151 – 02-175100


Adjustment
8T SAE 8 – – 02-175101
S – Screw with locknut
K – Handknob with locknut See section J for housing details.
H – Calibrated handknob with
NOTE:
locknut
To reset scale and knob to an
5 Valve housing material optimum viewing position:

Omit for cartridge only 1. Loosen the set screw


S – Steel 2. Rotate zero point on scale to a desired
A – Aluminum orientation.
3. Align mark on knob with zero on scale.
38,1 4. Tighten the set screw firmly.
"H" adjustment (1.50)
"K" adjustment To change the setting:
30,5
Dimensions "S" Ø38,1 (1.20) 1. Loosen the set screw
61,1
mm (inch) adjustment (1.50) 2. Loosen jamnut while holding the knob
(2.40) steady, or move the knob along the axis
Torque cartridge 4,75 (0.19) hex max. slightly.
in housing 3. Turn adjusting screw (jamnut and knob
A – 47–54 Nm will turn at the same time).
(35–40 ft.lbs) 4. At the new adjusting screw position,
S – 68–75 Nm 56,9 tighten jamnut firmly while holding the
(2.24) 72,4
(50–55 ft.lbs) (2.85) knob steady, or move the knob along
25,4
axis slightly.
(1.00)
“K” adjustment hex 5. Tighten the set screw firmly.
kit – 565585
Aluminum hous-
ings can be used
31,8 76,5 • for pressures up to
0.875"–14 2 (1.25) (3.01) 210 bar (3000 psi)
Thd. max. Steel housings must be used
for operating pressures above
1 210 bar (3000 psi)
Ø15,8 (0.62)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-17


FAR1-12
Flow regulator, pressure
compensated, fully
adjustable

Description Operation
The FAR1–12 is a two-way, This valve maintains a con- the valve to obtain pressure clockwise to decrease the
fully adjustable, pressure stant flow from port 1 to compensated control. The flow and counter- clockwise
compensated, flow regula- port 2 regardless of pres- regulated flow base within to increase the flow. This
tor, screw-in cartridge valve sure changes upstream of the adjusting range from valve allows free reverse
with free reverse flow. port 1, or downstream of 1,5 to 94,5 lpm (0.4 to 25 flow from port 2 to port 1.
port 2. 15,9 bar (230 psi) USgpm) is set by turning
Functional Symbol must be maintained across the adjusting screws
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 315 bar (4500 psi)
Min. pressure differential across valve 15,9 bar (230 psi)
Max. pressure differential across valve 329 bar (4770 psi)
1 Rated flow 1,5–94,5 L/min (.4–25 USgpm)
Sectional View Flow regulation accuracy 1,5–3,8 L/min (.4–1.0 USgpm) ±20% @5000 psi
above 3,8–68,1 L/min (above 1–18 USgpm) ±10% @3000 psi
above 68,1–94,6 L/min (above 18–25 USgpm) ±15% @3000 psi
3,8–56,8 L/min (1–15 USgpm) ±10% @5000 psi
above 56,8–89,1 L/min (above 15–23 USgpm) ±15% @5000 psi
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Reverse check crack pressure 1,7 bar (25 psi)
Leakage at shutoff position 0,5 L/min (30 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–12–2 & C–12–2U
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,43 kg (0.95 lbs.)
Seal kits 02–181304 Buna-N
2 02–181305 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation


Cartridge only
1
PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION
Flow - L/min (21,8 cSt oil @ 49 °C) Pressure differential across valve in bar
15 30 45 60 75 90 70 140 210 280 350
200 90
24
Pressure drop - bar

(105 SUS oil @ 120°F)


Pressure drop - psi

12 75
20
(21,8 cSt oil @ 49°C)

150
Flow - L/min
Flow - USgpm

16 60
8
100 12 45

8 30
50 4
4 15

0 4 8 12 16 20 24 0 1000 2000 3000 4000 5000


Flow - USgpm (105 SUS oil @ 120°F) Pressure differential across valve in psi

F-18 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FAR1-12

FAR1 – 12 (V) – * – * – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size

FAR1 – Fully adjustable, 0 – Cartridge only


pressure compensated flow
regulator with reverse flow CODE PORT SIZE HOUSING NUMBER
check C-12-2U C-12-2 C-12-2U C-12-2
Aluminum Aluminum Steel Steel
2 Size Fatigue rated Fatigue rated Fatigue rated Fatigue rated
12 – 12 Size 10T(U) SAE 10 02–160641 02-160640 02-169817 02-169744 F
3 12T(U) SAE 12 02–160645 02-160644 02-169790 02-169782
Seals
4G(U) 1/2” BSPP 02–161116 02-161118 02-172512 02-172062
Blank– Buna-N
V – Viton® 6G(U) 3/4” BSPP 02–161115 02-161117 02-162922 02-169665
See section J for housing details.
4 Adjustment
S – Screw with locknut
K – Handknob with locknut 7 Factory set flow rate,
H – Calibrated handknob with 8 Special features
locknut Blank – Normal factory
setting at 10 USgpm 00 – None
5 Valve housing material User requested setting (Only required if valve has NOTE:
Within .04–25 US gpm special features, omitted
Omit for cartridge only To reset scale and knob to an
S – Steel (1,5-–94,6 L/min.) up to if “00”.) optimum viewing position:
A – Aluminum 210 bar (3000 psi)
Within 0.4-23 USgpm 1. Loosen the set screw.
(1,5-87,1 L/min.) up to 2. Rotate zero point on scale to a desired
350bar (5000 psi) orientation.
3. Align mark on knob with zero on scale.
38,1
"H" adjustment 4. Tighten the set screw firmly.
(1.50)
"K" adjustment To change the setting:
30,5
"S" Ø38,1 (1.20) 1. Loosen the set screw.
73,1
Dimensions adjustment (2.88) (1.50) 2. Loosen jamnut while holding the knob
mm (inch) 4,75 (0.19) hex max. steady, or move the knob along the axis
slightly.
Torque cartridge
3. Turn adjusting screw (jamnut and knob
in housing will turn at the same time).
A – 81–95 Nm
67,2 4. At the new adjusting screw position,
(60–70 ft.lbs) 82,6 tighten jamnut firmly while holding the
S – 102–115 Nm 31,7 (2.65)
(3.25) knob steady, or move the knob along
(75–85 ft.lbs) (1.25) axis slightly.
hex 5. Tighten the set screw firmly.
“K” adjustment
kit – 565585 Aluminum hous-
ings can be used
• for pressures up to
44,7 88,4 210 bar (3000 psi)
1. 06"–12 2 (1.76) (3.48) Steel housings must be used
Thd. max. for operating pressures above
210 bar (3000 psi)
1
Ø23,7 (0.94)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-19


FAR1-16
Flow regulator, pressure
compensated, fully
adjustable

Description Operation
The FAR1–16 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor screw-in cartridge valve. sure changes upstream of regulated flow base within and counter- clockwise to
port 1, or downstream of the adjusting range from increase the flow. This valve
Functional Symbol port 2. 17 bar (250 psi) 3,8 to 113,6 L/min (1.0 to 30 allows free reverse flow
2 from port 2 to port 1.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
1 Min. pressure differential across valve 17 bar (250 psi)
Max. pressure differential across valve 328 bar (4750 psi)
Sectional View Rated flow 3,8–113,6 L/min (1–30 USgpm)
Flow regulation accuracy 3,8–15,1 L/min (1.0–4.0 USgpm) ±30% @5000 psi
above 15,1–30,3 L/min (above 4.0–8.0 USgpm) ±20% @5000 psi
above 30,3–113,6 L/min (above 8.0–30.0 USgpm) ±10% @5000 psi
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Reverse check crack pressure 1,7 bar (25 psi)
Leakage at shutoff position 0,55 L/min (33.5 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,67 kg (1.48 lbs.)
“K” 0,70 kg (1.55 lbs.)
2 “H” 0,74 kg (1.62 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Viton is a registered trademark of E.I. DuPont

1 Typical Flow Regulation


Cartridge only

PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION


Flow - L/min (21,8 cSt oil @ 49°C) Pressure differential across valve in bar
20 40 60 80 100 120 100 240 300 350
200 36
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)

12 120
Pressure drop - psi

30
Pressure drop - bar

Flow - USgpm

Flow - L/min

150 100
24 80
8
100 18 60
4 12 40
50
6 20

0 6 12 18 24 30 36 1000 2000 3000 4000 5000


Flow - USgpm (105 SUS oil @ 120°F) Pressure differential across valve in psi

F-20 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code FAR1-16

FAR1 – 16 (V) – * – * – *** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size & valve bodies 7 Factory set flow rate

FAR1 – Fully adjustable, 0 – Cartridge only Blank – Normal factory


pressure compensated flow CODE PORT SIZE HOUSING NUMBER setting at 15 USgpm
regulator with reverse flow User requested setting
Aluminum Aluminum Steel
check Light duty Fatigue rated Fatigue rated
Within 1–30 USgpm
(3,8-–113,6 L/min.) Port
2 Size 4G 1/2” BSPP – 876716 02-175106 bodies
16 – 16 Size 6B 3/4” BSPP 02-175463 – –
8
F
Special features
6G 3/4” BSPP – 876718 02-175107
3 Seals 00 – None
10T SAE 10 – – –
Blank– Buna-N (Only required if valve has
V – Viton® 10H SAE 10 – 876717 02-175104 special features, omitted
12T SAE 12 566149 – – if “00”.)
4 Adjustment 12H SAE 12 – 566113 02-175105
S – Screw with locknut See section J for housing details.
K – Handknob with locknut
H – Calibrated handknob with
NOTE:
locknut
To reset scale and knob to an
5 Valve housing material optimum viewing position:

Omit for cartridge only 1. Loosen the set screw.


S – Steel 2. Rotate zero point on scale to a desired
A – Aluminum orientation.
"H" Adjustment 38,1
3. Align mark on knob with zero on scale.
"K" Adjustment 4. Tighten the set screw firmly.
30,5 (1.50)
"S" Adjustment 82,1 Ø38,1 To change the setting:
4,75 (0.19) hex (3.40) max. (1.50) (1.20)
79,1 1. Loosen the set screw.
(3.11) 2. Loosen jamnut while holding the knob
Dimensions steady, or move the knob along the axis
mm (inch) slightly.
38,1 94,5 3. Turn adjusting screw (jamnut and knob
Torque cartridge (3.72)
(1.50) will turn at the same time).
in housing hex
A – 108–122 Nm 4. At the new adjusting screw position,
(80–90 ft.lbs) tighten jamnut firmly while holding the
79,1
knob steady, or move the knob along
S – 136–149 Nm (3.11) axis slightly.
(100–110 ft.lbs)
5. Tighten the set screw firmly.
“K” adjustment kit – 02-185169
101,9
46,4 (4.01) Aluminum hous-
(1.83) max. ings can be used
1.312"–12 T hd.
• for pressures up to
28,5 210 bar (3000 psi)
(1.12) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 F-21


PFR5-8
Priority flow regulator, fixed

Description Operation
The PFR5–8 is a fixed ori- This valve maintains a con- changes downstream on the spool will shift to try
fice, priority type, pressure stant, factory-set, priority port 3. Flow in excess of and satisfy the priority flow
compensated, flow regula- flow from port 1 to port 3 the priority setting is direct- requirement, thereby clos-
tor, screw-in cartridge based on 5.5 bar (80 psid) ed to port 2. If the priority ing off flow to port 2.
valve. regardless of pressure flow at port 3 is blocked,

Functional Symbol RATINGS AND SPECIFICATIONS

3 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) in steel housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated flow maximum inlet flow 15,1 L/min (4 USgpm)
maximum regulated flow 10 L/min (2.5 USgpm)
2
Internal leakage 82 cm3 /min. @ 350 bar (3000 psi) 5 in3 /min @ 5000 psi) F
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
1 0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–10 L/min (1.5–2.5 USgpm) ±10% @ 350 bar (5000 psi)
Sectional View Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–8–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,07 kg (0.15 lb.)
3 Seal kits 02–173427 Buna-N
02–173434 Viton®
Viton is a registered trademark of E.I. DuPont

2 Typical Flow Regulation


Cartridge only
Pressure - bar
350 280 210 140 70 0 70 140 210 280 350
1 3.0 12

2.5 10
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)


Flow - USgpm

Flow - L/min

2.0 8

1.5 6

1.0 4

0.5 2

0
0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Priority pressure
higher than priority higher than bypass
Pressure - psi

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-25


Model Code PFR5-8

PFR5 – 8 (V) – F – (*) – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate,

PFR5 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


CODE PORT SIZE HOUSING NUMBER
Range 0,4–9,5 L/min
2 Size (0.1–2.5 USgpm)
Aluminum Steel Example:
8 – 8 Size Fatigue rated Fatigue rated
0.5–1,9 L/min (0.5 USgpm)
3 Seals 4T SAE 4 02–160741 02-160745
8 Special features
Blank– Buna-N 6T SAE 6 02–160742 02-160746
V – Viton® 2G 1/4” BSPP 02–160739 02-160743 00 – None
(Only required if valve has
3G 3/8” BSPP 02–160740 02-160744
4 Adjustment special features, omitted
See section J for housing details. if “00”.)
F – Fixed orifice
SS - 316 Stainless Steel
5 Valve housing material external components
Omit for cartridge only
S – Steel
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in steel


or aluminum housing to
34–41 Nm (25–30 ft.lbs) 8,5
(0.33) 22,1 (.870) hex

0.750"–16 Thd.

40,6 3
(1.60)

Aluminum hous-
1 ings can be used
Ø14,2 (0.559) • for pressures up to
210 bar (3000 psi)
Ø15,8 (0.622) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

F-26 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


PFR5-10
Priority flow regulator, fixed

Description Operation
The PFR5-10-F is a fixed This valve maintains a con- changes downstream on the spool will shift to satis-
orifice, priority type, stant, factory-set, priority port 3. Flow in excess of fy the priority flow require-
pressure compensated, flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
flow regulator screw-in based on 5.5 bar (80 psid) ed to port 2. If the priority flow to port 2.
cartridge valve. regardless of pressure flow at port 3 is blocked,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow Maximum inlet flow 60 L/min (15 USgpm)
Maximum regulated flow 23 L/min (6 USgpm)
3 Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi) F
5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges.

2 Temperature range -40° to 120°C (-40° to 248°F)


Cavity C–10–3
1 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18 /16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,13 kg (0.28 lb.)
Sectional View Seal kits 565804 Buna-N
889599 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation


Cartridge only

Pressure - bar
350 280 210 140 70 0 70 140 210 280 350
6.0 24
3
5.0 20
(105 SUS oil @ 120°F)

(21,8 cSt oil @ 49°C)


Flow - USgpm

Flow - L/min

4.0 16
2
3.0 12

2.0 8
1
1.0 4

0 0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Pressure - psi Priority pressure
higher than priority higher than bypass

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-27


Model Code PFR5-10

PFR5 – 10 (V) – F – * – ** – *.*– 00

1 2 3 4 5 6 7 8

1 Function 6 Port size 7 Factory set flow rate

PFR5 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


CODE PORT SIZE HOUSING NUMBER
Range 0,38–22,7 L/min
2 Size (0.1–6.0 USgpm)
Aluminum Aluminum Steel
10 – 10 Size Light duty Fatigue rated 8 Special features
3 Seals 2G 1/4” BSPP – 876705 02-175127 00 – None
Blank– Buna-N 3B 3/8” BSPP 02–173358 – – (Only required if valve has
V – Viton® 3G 3/8” BSPP – 876714 02-175128 special features, omitted
if “00”.)
4 6T SAE 6 566162 – 02-175124
Adjustment
F – Fixed orifice 6H SAE 6 – 876704 –
8H SAE 8 – 876711 –
5 Valve housing material
8T SAE 8 – 02-175125 –
Omit for cartridge only See section J for housing details.
S – Steel
A – Aluminum

Dimensions
mm (inch)

Torque cartridge in housing


A – 47–54 Nm (35–40 ft.lbs) 25,4 (1.0) hex
S – 68–75 Nm (50–55 ft.lbs) 20,8
(0.82)

0.875"?-14 Thd.
46,0
(1.81) 3

1
Aluminum hous-
Ø15,82 (0.623) ings can be used
• for pressures up to
210 bar (3000 psi)
Ø17,42 (0.686) Steel housings must be used
for operating pressures above
210 bar (3000 psi)

F-28 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


PFR2-16
Priority flow regulator,
adjustable

Description Operation
The PFR2-16 is a limited This valve maintains a con- of pressure changes down- blocked, the spool will shift
range adjustable*, priority stant, factory-set, priority stream on port 3. Flow in to satisfy the priority flow
type, pressure compensat- flow from port 1 to port 3 excess of the priority set- requirement, thereby clos-
ed, flow regulator screw-in based on the setting adjust- ting is directed to port 2. If ing off flow to port 2.
cartridge valve. ment, regardless the priority flow at port 3 is
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate. Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow Maximum inlet flow 151 L/min (40 USgpm)
Maximum regulated flow 114 L/min (30 USgpm)
3
Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10% F
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F
2 Cavity C–16–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,43 kg (0.95 lb.)
Seal kits 565811 Buna-N
Sectional View 889610 Viton®
Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation A – Port 3, priority


Cartridge only (regulated) outlet
pressurized
B – Port 2, bypass outlet
pressurized

Back pressure - bar


0 35 75 100 140 175 210
Priority (regulated) flow rate - USgpm

Priority (regulated) flow rate - L/min

100
25
A
(105 SUS oil @ 120°F)

80
(21,8 cSt oil @ 49°C)

20
B
60
15
A
3
40
10
B
2
20
5

1 0
0
0 500 1000 1500 2000 2500 3000
Back pressure - psi

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-33


Model Code PFR2-16

PFR2 – 16 (V) – * – *** – *.*– 00

1 2 3 4 5 6 7

1 Function 5 Port size 6 Factory set flow rate,

PFR2 – Priority flow regulator 0 – Cartridge only (Specify in USgpm)


Range 1,9–114 L/min
2 CODE PORT SIZE HOUSING NUMBER
Size (0.5–30 USgpm)
16 – 16 Size Aluminum Aluminum
Light duty Fatigue rated 7 Special features
3 Seals 12T SAE 12 566152 – 00 – None
Blank– Buna-N 6B 3/4” BSPP 02-175465 – (Only required if valve has
V – Viton® 10H SAE 10 – 876721 special features, omitted
if “00”.)
4 12H SAE 12 – 876723 SS - 316 Stainless Steel
Adjustment
C – Cap 4G 1/2” BSPP – 876720 external components
K – Knob 6G 3/4” BSPP – 876722
S – Screw See section J for housing details.

Dimensions
mm (inch)
"C" Adjustment "S" Adjustment
9,6 (0.37) hex "K" Adjustment,
Torque cartridge in 19,0 (0.75) hex
aluminum housing to Ø51 (2.0)
108–122 Nm (80–90 ft.lbs)

107,2 104,0
(4.22) (4.09)

38,1 (1.50) hex

1.312" -12 Thd.

73,0 3
(2.87)
2

1
Ø26,95 (1.061)

Ø28,55 (1.124)

F-34 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


PFRD/S-12
Priority flow regulator valve

Description Operation
The PFR*-12 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to maximum
tems in steering and brak- ports 2 and 4 must be pro- pressure.
ing circuits. The static type vided by external relief
F
3 P
RATINGS AND SPECIFICATIONS
Static Signal (PFRS)
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF
Typical application pressure (all ports) 280 bar (4000 psi)
4 2
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
1 Rated inlet flow 76 L/min (20 USgpm)
LS 5
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–12–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Profile View Filtration Cleanliness code 18/16/13
Housing materials Aluminum or Steel
Weight cartridge only 0,36 kg (0.79 lb.)
Seal kit 202914-921
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.031” (not included in valve)

Pressure Drop Curves


5 LS Flow - L/min
Cartridge only
10 20 30 40 50 60 70 80 90
4 CF 290 20
Pressure drop bar

218 15
Pressure drop psi

3 P

2 EF 145 10
Notes
Minimum inlet flow should 73 5
1 not be less than 1/4 of
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-35


Model Code PFRS/D-12

PFR* 12 U * *** *** 00

1 2 3 4 5 6 7

1 Function 5 Ports* 6 Control Pressure

PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 055 psi (3.8 bar)
PFRD – Priority flow 078 psi (5.4 bar)
000 No Body – – –
regulator 100 psi (6.9 bar)
Dynamic signal type 10T SAE 10 SAE 4 4998820-001 4998821-001 PFRD options
12T SAE 12 SAE 4 4998820-002 4998821-002 075 psi (5.2 bar)
2 Size 110 psi (7.6 bar)
04G 1/2” BSPP 1/4” BSPP 4998820-003 4998821-003
12 – 12 Size 145 psi (10.0 bar)
06G 3/4” BSPP 1/4” BSPP 4998820-004 4998821-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)

Dimensions
mm (inch)

Torque cartridge in housing


A – 81-95 Nm (60–70 ft.lbs)
1 1/4" HEX
S – 102–115 Nm (75–85 ft.lbs) 33.3
(1.31)

Note
1 1/16"-1 2 UN-2A
Standard housings include
port 1, however for most
applications this port must
be blocked. 5 LS

4 CF
86.4
(3.40)

3 P Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
1 210 bar (3000 psi)

F-36 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


PFRD/S-16
Priority flow regulator valve

Description Operation
The PFR*-16 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
Dynamic Signal (PFRD)
port 2. The valve maintains response or circuit stability control pressure must be
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be pro- sure.
ing circuits. The static type vided by external relief
F
3 P
RATINGS AND SPECIFICATIONS
Static Signal (PFRS) Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF Typical application pressure (all ports) 280 bar (4000 psi)
4 2 Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 150 L/min (40 USgpm)
LS 5 1
Temperature range -40° to 100° C (-40° to 210° F)
Cavity C–16–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Profile View Housing materials (standard) Steel
Weight cartridge only 0,47 kg (1.05 lbs.)
Seal kit 202915-922
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.036” (not included in valve)

5 LS
Pressure Drop Curves Flow - L/min
38 75 114 151
Cartridge only 250
4 CF

14
Pressure drop psi

200
Pressure drop bar

3 P

150 10
2 EF
100 7
1 Notes
Minimum inlet flow should
50 3
not be less than 1/4 of
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20 25 30 35 40 45
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-37


Model Code PFRS/D-16

PFR* 16 U * *** *** 00

1 2 3 4 5 6 7

1 Function 5 Ports* 6 Control Pressure

PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 065 psi (4.5 bar)
PFRD – Priority flow 130 psi (8.9 bar)
000 No Body – – –
regulator 160 psi (11.0 bar)
Dynamic signal type 12T SAE 12 SAE 4 4994880-001 4994881-001 PFRD options
16T SAE 16 SAE 4 4994880-002 4994881-002 080 psi (5.5 bar)
2 Size 110 psi (7.6 bar)
06G 3/4” BSPP 1/4” BSPP 4994880-003 4994881-003
16 – 16 Size 130 psi (9.0 bar)
08G 1” BSPP 1/4” BSPP 4994880-004 4994881-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)

Dimensions
mm (inch)

Torque cartridge in housing


A – 108-122 Nm (80-90 ft. lbs)
S – 136–149 Nm (100–110 ft. lbs) 17.8 (.70) 1.50" HEX

Note 1 5/16"-2 UN-2A


Standard housings include
port 1, however for most
5 LS
applications this port must
be blocked.

4 CF

96.3 (3.79)

3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1

F-38 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


PFRD/S-20
Priority flow regulator valve

Description Operation
The PFR*-20 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sensing flow control mode. Pump applications where is determined by assuring
priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 Meters The pressure at port 4 can
changes at 2 or 4. This (6 Feet) in length. vary by 10% when the load
valve is typically used with Overpressure protection for at the excess flow port 2
LS 5 1
open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be sure.
ing circuits. The static type provided by external relief
F
3 P RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Static Signal (PFRS)
Typical application pressure (all ports) 240 bar (3500 psi)
CF EF Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
4 2 Rated inlet flow 230 L/min (60 USgpm)
Temperature range -40° to 100° C (-40° to 210° F)
LS 5 1
Cavity C–20–5S
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
3 P Filtration Cleanliness code 18/16/13
Housing materials (standard) Steel
Profile View Weight cartridge only 0,86 kg (1.9 lbs.)
Seal kit 02-187543
Internal leakage 164 cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.047” (not included in valve)

Pressure Drop Curves


Flow - L/min
5 LS Cartridge only
75 151 227
250
4 CF
200 14
Pressure drop psi

Pressure drop bar

3 P
150

2 EF 100 7
Note
Minimum inlet flow should
not be less than 1/4 of 50
maximum inlet flow.
1
0
Note Minimum pressure drop 10 20 30 40 50 60
Port 1 unused, port should is determined by control Inlet flow (GPM)
be plugged. pressure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-39


Model Code PFRS/D-20

PFR* 20 U * *** *** 00

1 2 3 4 5 6 7

1 Function 5 Ports* 6 Control Pressure

PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 080 psi (5.5 bar)
PFRD – Priority flow regulator 100 psi (6.9 bar)
000 No Body – – –
Dynamic signal type PFRD options
12T SAE 12 SAE 4 4998822-001 4998823-001 085 psi (5.9 bar)
2 Size 16T 110 psi (7.6 bar)
SAE 16 SAE 4 4998822-002 4998823-002
20 – 20 Size 06G 3/4” BSPP 1/4” BSPP 4998822-003 4998823-003 7 Special features
3 08G 1” BSPP 1/4” BSPP 4998822-004 4998823-004
Seals 00 – None
* These model digits will not be stamped on the valve. (Only required if valve has
U– Urethane (standard)
See section J for housing details. special features, omitted
4 Body if “00”.)
O – Cartridge only
A – Aluminum
S – Steel (standard)

Dimensions
mm (inch)

Torque cartridge in housing 1 7/8 HEX.


A – 130-155 Nm (95-115 ft. lbs) 20,3 (.80)
S – 160–180 Nm (120–135 ft. lbs)

1 5/8 -12 UN-2A


Note
Standard housings include 5 LS
port 1, however for most
applications this port must
be blocked. 4 CF
105,2 (4.14)

3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1

F-40 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


PCS4-10
Pressure compensator

Description Operation
The PCS4-10 is a screw-in, This valve, when used with port 3. This is based on priority port is deadheaded,
pressure compensator either a fixed or variable whatever pressure differen- the valve will try to direct
cartridge for the use orifice on port 4, maintains tial is chosen. All flow in flow out of the priority port
as a bypass or priority a constant flow out port 3, excess of the priority and shut off the bypass
flow control. regardless of pressure requirement is bypassed flow, blocking of all flow.
changes downstream of from port 1 to port 2. If the
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbols Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 38 L/min (10 USgpm)
Cavity C–10–4
Variable
or fixed Standard housing materials Customized housings are
restrictor necessary for close-coupling
upstream the compensator and orifice
4 3 Temperature range -40° to 120°C (-40° to 248°F)
1 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,14 kg (0.32 lbs)
Seal kits 889651 Buna-N
889653 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View

Performance A – 2,8 bar (40 psi) (control P)


Characteristics
B – 5,5 bar (80 psi) (control P)
Cartridge only
C – 11,0 bar (160 psi) (control P)

4 Controlled flow - L/min (21,8 cSt oil @ 49°C)


0 4 8 12 16 20 24 28 32 36
Approx. orifice diameter - inches

0.200 5
Approx. orifice diameter - mm

0.175
3 A 4
0.150
B
0.125
C 3
0.100
2 0.075 2
0.050
1
0.025
1 0 0
0 1 2 3 4 5 6 7 8 9 10
Controlled flow - USgpm (105 SUS oil @ 120°F)

I-30 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS4-10

PCS4 – 10 (V) – * – *** – 00

1 2 3 4 5 6

1 Function 3 Seals 4 Port size 5 Pressure differential


PCS4 – Pressure Blank – Buna-N 0 – Cartridge only (nominal)
compensator bypass type V – Viton Customized housings are 40 – 2,8 bar (40 psi)
necessary for close-coupling, 80 – 5,5 bar (80 psi)
2 Size compensator and orifice 160 – 11,0 bar (160 psi)
10 – 10 Size
6 Special features

00 – None
(Only required if valve has
special features, omit if 00)

Dimensions
mm (inch)

19,0 I
Torque into aluminum (0.75) 25,4 (1.00) hex
housing to 47-54 Nm
(35-40 ft. lbs)

0.875 -14 Thd.

4
61,9
(2.43)
3

1
15,80 (0.622)
17,40 (0.685)
18,97 (0.747)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-31


PCS4-12
Pressure compensator

Description Operation
The PCS4-12 is a screw-in, This valve, when used with port 3. This is based on priority port is deadheaded,
pressure compensator either a fixed or variable whatever pressure differen- the valve will try to direct
cartridge for the use orifice on port 4, maintains tial is chosen. All flow in flow out of the priority port
as a bypass or priority a constant flow out port 3, excess of the priority and shut off the bypass
flow control. regardless of pressure requirement is bypassed flow, blocking of all flow.
changes downstream of from port 1 to port 2. If the
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 240 bar (3500 psi)
Functional Symbols Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated flow 58 L/min (15 USgpm)
Cavity C–12–4
Variable
or fixed Standard housing materials Customized housings are
restrictor necessary for close-coupling
upstream the compensator and orifice
4 3 Temperature range -40° to 120°C (-40° to 248°F)
1 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,36 kg (0.80 lbs)
Seal kits 9900335-000 Buna-N
9900336-000 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View

Performance A – 2,8 bar (40 PSI) Control DP


Characteristics B – 5,5 bar (80 PSI) Control DP
Cartridge only C – 11,0 bar (120 PSI) Control DP

0.350

0.300
EXTERNAL ORIFICE DIAMETER (INCH)

A
0.250
4 B

0.200

3 0.150 C

0.100
2
0.050

0.000
1 0 5 10 15
FLOW (GPM)

I-32 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS4-12

PCS4 – 12 (V) – * – *** – 00

1 2 3 4 5 6

1 Function 3 Seals 4 Port size 5 Pressure differential


PCS4 – Pressure Blank – Buna-N 0 – Cartridge only (nominal)
compensator bypass type V – Viton Customized housings are 40 – 2,8 bar (40 psi)
necessary for close-coupling, 80 – 5,5 bar (80 psi)
2 Size compensator and orifice 120 – 8,3 bar (120 psi)
12 – 12 Size
6 Special features

00 – None
(Only required if valve has
special features, omit if 00)

Dimensions
mm (inch) 31,7 (1.25) HEX

33,3 (1.31) I
Torque into aluminum
housing to 81-45 Nm 1 1/16 - 12 UNF - 2A THREAD
(60-75 ft. lbs)

90,2 (3.55)

20,6 (.810)
22,1 (.872)
23,7 (.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-33


PCS4-16
Pressure compensator

Description Operation
The PCS4-16 is a screw-in, This valve, when used with port 3. This is based port 2. If the priority port is
pressure compensator either a fixed or variable on whatever pressure deadheaded, the valve will
cartridge for the use orifice on port 4, maintains differential is chosen. All try to direct flow out of the
as a bypass or priority a constant flow out port 3, flow in excess of the priority port and shut off
flow control. regardless of pressure priority requirement is the bypass flow, blocking
changes downstream of bypassed from port 1 to of all flow.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbols Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 114 L/min (30 USgpm)
Variable Cavity C–16–4
or fixed
restrictor Standard housing materials Customized housings are
upstream necessary for close-coupling,
4 3 the compensator and orifice
Temperature range -40° to 120°C (-40° to 248°F)
1 2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,50 kg (1.12 lbs)
Seal kits 889660 Buna-N
02-175435 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Performance A – 2,8 bar (40 psi) (control P)


Characteristics
B – 5,5 bar (80 psi) (control P)
Cartridge only C – 11,0 bar (160 psi) (control P)

Controlled priority flow , port 3 - L/min (21,8 cSt oil @ 49˚ C)


4 0 15 30 45 60 75 90 105
Approx. orifice diameter - inches

0.400
Approx. orifice diameter - mm

10
0.350
A 8
0.300
B
3 0.250
C 6
0.200
0.150 4
2 0.100
2
0.050
0 0
0 3 6 9 12 15 18 21 24 27 30
1
Controlled priority flow , port 3 - USgpm (105 SUS oil @ 120˚ F)

I-34 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS4-16

PCS4 – 16 (V) – * – *** – 00

1 2 3 4 5 6

1 Function 3 Seals 4 Port size 5 Pressure differential


PCS4 – Pressure Blank – Buna-N 0 – Cartridge only (nominal)
compensator, bypass type V – Viton (Customized housings are 40 – 2,8 bar (40 psi)
necessary for close-coupling, 80 – 5,5 bar (80 psi)
2 Size compensator and orifice 160 – 11,0 bar (160 psi)
16 – 16 Size
6 Special features

00 – None
(Only required if valve has
special features, omit if 00)

Dimensions
mm (inch)
28,6
(1.12) 38,1 (1.50) hex
I
Torque into aluminum
housing to 108-122 Nm
(80-90 ft. lbs)

1.312 -12 Thd.

4
101,6
(4.00)
3

1
25,37 (0.999)
26,95 (1.061)
28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-35


PCS4-20
Pressure compensator

Description Operation
The PCS4-20 is a screw-in, This valve, when used with port 3. This is based on If the priority port is dead-
pressure compensator either a fixed or variable ori- whatever pressure differen- headed, the valve will try
cartridge for the use fice on port 4, maintains a tial is chosen. All flow in to direct flow out of the
as a bypass or priority constant flow out port 3, excess of the priority priority port and shut off
flow control. regardless of pressure requirement is bypassed the bypass flow, blocking of
changes downstream of from port 1 to port 2. all flow.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbols Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 189 L/min (50 USgpm)
Variable Cavity C–20–4
or fixed
restrictor Standard housing materials Customized housings are
upstream necessary for close-coupling,
4 3 the compensator and orifice
Temperature range -40° to 120°C (-40° to 248°F)
1 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,50 kg (1.12 lbs)
Seal kits 889660 Buna-N
02-175435 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont

Performance A – 2,8 bar (40 psi) (control P)


Characteristics
B – 5,5 bar (80 psi) (control P)
Cartridge only

Controlled priority flow port 3,


- L/min (21,8 cSt oil @ 49˚ C)
4
0 35 70 105 140 175 210 245
Approx. orifice diameter - inches

0.600 15
Approx. orifice diameter - mm

0.500 12
3
A
0.400
B 9
0.300
2 0.200 6

0.100 3

0 0
1 0 7 14 21 28 35 42 49 56 63 70
Controlled priority flow port 3,
- USgpm (105 SUS oil @ 120˚ F)

I-36 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS4-20

PCS4 – 20 (V) – * – *** – 00

1 2 3 4 5 6

1 Function 3 Seals 4 Port size 5 Pressure differential


PCS4 – Pressure Blank – Buna-N 0 – Cartridge only (nominal)
compensator, V – Viton (Customized housings are 40 – 2,8 bar (40 psi)
bypass type necessary for close- 80 – 5,5 bar (80 psi)
coupling, compensator and
2 Size orifice 6 Special features
20 – 20 Size 00 – None
(Only required if valve has
special features, omit if 00)

Dimensions
mm (inch)

41,3 I
Torque into aluminum (1.62) 47,6 (1.87) hex
housing to 128-155 Nm
(95-115 ft. lbs)

1.625 -12 Thd.

4
139,7
(5.50)
3

1
31,70 (1.248)
33,30 (1.311)
36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-37


FDC1-20
Flow divider/combiner

Description Operation
The FDC1-20 is a line This valve is used in the regardless of system pres- flows from ports 2 and 3
mounted pressure dividing mode. It will take sure to ports 2 and 4. and combine them into port
compensated, spool type, the inlet flow (port 1) and In the combining mode this 1 according to the ratio
flow divider/combiner split the flow according to valve will take the inlet specified.
valve. the ratio specified,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Fluids All general purpose hydraulic fluids such as:
2 3 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13 F
Standard housing materials Aluminum
Weight cartridge only 2,6 kg. (5.75 lbs.)
1 Seal Kits 889639 Buna–N
889643 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Pressure Drop Curves Flow Division:


(See model code position 5)
A - 3* spool
2 B - 4* spool
C - 6* spool
D - 8* spool
1
Inlet flow rate, port 1, - L/min (21,8 cSt oil @ 49°C)
0 100 200 300
3
30
400
A
Pressure drop - bar
Pressure drop - psi

25

300 20
B
15
200
C 10
100
5
D
0
0 20 40 60 80 100
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-73


Model Code FDC1-20

FDC1 – 20 (V) – *** – **– 00

1 2 3 4 5 6

1 Function 5 Flow divisions (ratios) 6 Special features

FDC1 – Flow divider/ CODE FLOW DIVISION% MAX. INLET FLOW 00 – None
combiner Port 4 Port 2 L/min (USgpm) (Only required if valve has
special features, omitted
2 Size 33 50 50 190,0 (50)
if “00”.)
20 – 20 Size 34 43 57 228,0 (60)
36 33 67 266,0 (70)
3 Seals 44 50 50 266,0 (70)
Blank– Buna-N 46 40 60 304,0 (80)
V – Viton®
66 50 50 380,0 (100)
4 Port size 88 50 50 380,0 (100)
16T – SAE 16 (light duty)
20T – SAE 20 (light duty)
(Available as a complete
assembly only.)

178,0 (7.00)
152,4 (6.00) 12,7 (0.50)
Dimensions
mm (inch)
63,5
Torque cartridge in housing (2.50)
128–155 Nm (95–115 ft. lbs) 31,7
(1.25) 2 3

Note
Minimum inlet flow should 31,7 31,7
not be less than 1/4 of 12,7
(1.25) (1.25)
maximum inlet flow for a (0.50)
given code.

101,6 104,0
(4.00) (4.10)

76,2
(3.00)
50,8
(2.00)

44,4 44,4
1 (1.75) (1.75) Ø10,0 (0.406 thru) (3 plcs.)
76,2
(3.00)

F-74 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005


FDC3-20
Posi-traction valve

Description Operation
The FDC3-20 is a line This valve is used in the In the combining mode this port 1 according to the ratio
mounted, pressure dividing mode. It will take valve will take the inlet specified.
compensated, spool type, the inlet flow (port 1) and flows from ports 2 and 3
posi-traction cartridge split the flow to ports and combine them into
valve. 2 and 3.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol
Rated inlet flow See model code
2 3 Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
1 Weight cartridge only 2,6 kg. (5.75 lbs.)
Seal kits (2 req’d.) 889639 Buna–N
889643 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Pressure Drop Curves Flow Division


(See model code position 5)
A - 33 spool
2 B - 44 spool
C - 66 spool
D - 88 spool
1
Inlet flow rate, port 1, - L/min (21,8 cSt oil @ 49°C)
0 100 200 300 400 500 600
3 30
400
Pressure drop - bar

A C D
Pressure drop - psi

350 25
B
300
20
250
200 15
150
10
100
50 5
0
0 20 40 60 80 100 120 140
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E2 June 2005 F-83


Model Code FDC3-20

FDC3 – 20 (V) – *** – **– 00

1 2 3 4 5 6

1 Function 3 Seals 5 Flow divisions (ratios)


FDC3 – Posi-traction valve Blank – Buna-N CODE FLOW DIVISION% MAX. INLET FLOW
V – Viton® Port 4 Port 2 L/min (USgpm)
2 Size
4 Port size 33 50 50 190,0 (50)
20 – 20 Size 44 50 50 266,0 (70)
16T – SAE 16 (light duty) 66 50 50 380,0 (100)
20T – SAE 20 (light duty) 88 50 50 570,0 (150)
(Available as complete
assembly only.)
6 Special features
00 – None
(Only required if valve has
special features, omitted
if “00”.)

Dimensions
12,7 (0.50) 152,4 (6.00) 12,7 (0.50)
mm (inch)

Torque cartridge in housing 76,2


128–155 Nm (95–115 ft. lbs) (3.0)

63,5
Note (2.50)
Minimum inlet flow should 31,7
not be less than 1/4 of (1.25) 2 3
maximum inlet flow for
a given code.
12,7 31,7 (1.25) 31,7 (1.25)
(0.50)

101,6
(4.00)
104,0
76,2 (4.10)
(3.00)

44,4 44,4
(1.75) (1.75) Ø10,3 (0.406 thru) (3 plcs.)
1
76,2
(3.00)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Solenoid Valves
Section Overview

Quality Products and Vickers solenoid valves are Valve Features and • All exposed surfaces are
Innovative solutions offered with the widest Benefits zinc dichromate plated to
This catalog gives basic choice of flow paths and • Products in this catalog resist corrosion
specifications for the full position options to satisfy have been fatigue tested • All aluminum manifolds
line of Vickers screw-in most requirements. These for one million cycles at are gold anodized to
cartridge solenoid valves. options include: 132% or 10 million resist corrosion
Its purpose is to provide a • 2-way. 2-position, nor- cycles at 115% of rated • Reliable, economical and
quick, convenient reference mally open and normally pressure compact
tool when choosing Vickers closed spool and poppet • Rated flows up to 227
cartridge valves or design- valves • Manual override options
L/min (60 USgpm) are available on all sole-
ing a system using these • 3-way, 2-position spool
components. • Poppet and spool noid valves except SBV
valves designs series valves
Two pressure ratings are • 4-way, 2-position spool
shown for all products • Standard cartridge
valves Note
featured in this catalog - cavities
typical application pressure • 4-way, 3-position spool Solenoid valve coil
• All operating parts are
and fatigue pressure. The valves details are shown in
hardened steel, ground
typical application pressure section C.
and honed for long life
rating is the maximum and low leakage
recommended operating
• Cartridge design for
pressure for the valve in a
maximum flexibility and
given system. The fatigue
minimal manifold space
pressure rating is the
requirements
pressure for the valve to be
free for infinite life • Optional low-cost manu-
from metal fatigue. al override is available on
selected models

A-4 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Solenoid Valves
Coils

Coil Features The solenoid operated • Coils are rated for contin- An arc suppression diode
and Benefits directional valves in this uous duty molded into the coil is avail-
catalog are offered with a • Coils are interchangeable able as a standard option
choice of standard voltages for serviceability on DC coils. Also available,
and several types of electri- are explosion-proof coils
cal connections. For other • Variety of voltages and and cartridges that are CSA
coil ratings and connec- terminations approved and recognized by
Note tions, consult your Eaton • Coils offer a one-piece the US Underwriters
Solenoid valve coil representative. weather-proof encapsu- Laboratories.
details are shown in Standard AC coils are inter- lated design, eliminating
section C. nally rectified to supply the need for extra seals
them with DC current, • AC voltage coils are inter-
therefore they have no nally full-wave rectified
“inrush” current value. for 50 or 60 cycle (Hz)
applications

Protection of Internally The rectifiers used in these Protection is simple and supplying the rectified com-
Rectified Coils coils may require protection inexpensive. It consists of ponents. A single suppres-
from high voltage surges in installing a commercially sor will normally protect all
some electrical circuits con- available voltage surge sup- of the rectified components
taining highly inductive or pressor like the General in the circuit, as shown in
capacitive components. Electric MOV varistor the surge suppressor circuit
These include certain types V130LA20A for 115 volts AC diagram below.
of motors, solenoids, or the V250LA20A for 230
relays, and transformers. volts AC, across the AC line

Note AC line
Surge suppressor
Solenoid valve coil circuit diagram Voltage surge suppressor
details are shown in (MOV varistor)
section C. Rectified components

WARNING
• Application of
these products All voltage Switches
S or relay contacts only. Relay
beyond published perform- surge coils must be connected on the line
ance specifications may producing side of the surge suppressor.
cause valve malfunction components
which may result in per- must be No inductive or capacitive loads
installed on can be installed between the surge
sonal injury and/or dam-
this side of suppressor and rectified valves
age to the machine. suppressor. without additional precautions.

WARNING CAUTION
• Maintain 5-8 Nm • Coils may be
(4-6 ft. lbs) maxi- hot to touch
mum torque on valve tube if used in continuous
nut. Over tightening may applications.
cause valve or coil failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-5


SV13-10-O/OP/OS
Poppet type, normally open
solenoid valve, 350 bar
(free reverse flow)

Description Operation
The SV13-10-O is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, this valve allows bi- flow is blocked from port 2
poppet type, normally open directional flow between to port 1, and is allowed
screw-in solenoid cartridge port 1 and port 2. from port 1 to port 2, when
valve. coil forces are overcome.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 45 L/min (12 USgpm)
2
Internal leakage less than 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only
0 8 15 23 30 38 45
100 7
Pressure Drop - psi

Pressure Drop - bar


75 5

50
3
2
25
1
1
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
Application Note Port 1 to port 2 and port 2
This valve is pilot operated to port 1 de-energized
and requires a minimum
flow of 1-2 L/min (0.3- .5
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.

A-58 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV13-10-O

SV13 – 10 (V) – O (*) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV13 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size 7
Q - Spade terminals
Port Size W - Leadwire
10 - 10 size
CODE PORT SIZE HOUSING NUMBER N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-175102 (DC only)
V - Viton® 3G 3/8” BSPP 02-175103 J - Metripack 280 male
6T SAE 6 02-175100 (DC only)
4 Style
O - Normally open 8T SAE 8 02-175101 10 Coil series
See section J for housings. H - 10 series, 29 W
5 Manual override option
For dimensions see Section C.
Blank - No manual override
P - Push type 8 Voltage rating 24A - 24VAC
11 Special features
S - Screw type 115A - 115VAC
00 - No coil 00 - None
For valve dimensions with manual 230A - 230VAC
12D - 12VDC
override option installed see page A-152. 12B - 12VDC/w diode* (Only required if valve
24D - 24VDC
24B - 24VDC/w diode* has special features,
36D - 36VDC
*Optional arc suppression diode. omitted if “00.”)

29,6
Dimensions (1.16)
mm (inch)

Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs)

Ø 38,9
Note (1.53)
When solenoid valve is
ordered as cartridge only, 22,2 (0.875) hex
nut is included.

57,8
(2.28)

25,4 (1.00) hex


WARNING
Maintain 5-8 Nm 0.875" – 14 Thd.
• 31,7
(4-6 ft. lbs) maxi- (1.25)
mum torque on valve tube
2
nut. Over tightening may
cause valve failure. Ø 15,82 (.623)
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-59


SV3-10-C/CM/CR
Poppet type, normally
closed solenoid valve
(free reverse flow)

Description Operation
The SV3-10-C is a 2-way, In the de-energized posi- In the energized position,
2-position, poppet-type, tion, flow is blocked from the poppet lifts to allow
normally closed screw-in port 2 to port 1 and free flow in either direction.
cartridge solenoid valve. flow is allowed from port 1
to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
2 Internal leakage less than 5 drops/min. max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight cartridge only 0,4 kg (0.87 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 5 10 15 20 25 30 35 40 45
100 7

75 5

Pressure Drop - bar


Pressure Drop - psi

50
B 3
A
2
25
1
1
0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2 de-energized
B - Port 2 to port 1 energized

A-24 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV3-10-C

SV3 – 10 (V) – C (*) (F) – ** – **** * – 00

1 2 3 4 5 6 7 8 9 10

1 Function 7 Port Size 9 Connector types


SV3 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
G - ISO 4400 DIN 43650
2 Size 0 Cartridge only Q - Spade terminals
10 - 10 size 3B 3/8” BSPP 02-175462* W - Leadwire
2G 1/4” BSPP 876702 N - Deutsch (DC only)
3 Seal material Y - Amp JR (DC only)
3G 3/8” BSPP 876703
D - Metripack 150 male
Blank - Buna-N 6T SAE 6 566151* (DC only)
V - Viton® 6H SAE 6 876700 J - Metripack 280 male
4 8H SAE 8 876701 (DC only)
Style For coil part numbers and dimensions
C - Normally closed *Light duty housing see Section C.
See section J for housing details.
5 Manual override option 10 Special features
Blank - No manual override 8 Voltage rating 24A - 24VAC
115A - 115VAC 00 - None
M - Knob type 00 - No coil
R - Cable type 230A - 230VAC (Only required if valve
12D - 12VDC
12B - 12VDC/w diode* has special features,
For valve dimensions with manual 24D - 24VDC
24B - 24VDC/w diode* omitted if “00.”)
override option installed see page A-153. 36D - 36VDC
*Optional arc suppression diode.

6 Filter option Note


29,6
Blank - None (1.16) Use J series, 23 W coils
F - Filter screen with this solenoid valve.

Dimensions
mm (inch)

Torque cartridge in alu- Ø 38,9


minum housing 47-54 Nm (1.53)
(35-40 ft. lbs)
19,0 (0.75) hex
Note
When solenoid valve is
ordered as cartridge only,
57,1
coil nut is included.
(2.25)

25,4 (1.0 ) hex

0.875" – 14 Thd.
WARNING 31,7
• Maintain 5-8 Nm (1.25)
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may 1
cause valve failure. Ø 15,80 (0.622)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-25


SV13-12-O/OP/OS
Poppet type normally open
solenoid valve, 350 bar

Description Operation
The SV13-12-O is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, flow can pass through flow is blocked from port 2
poppet type, normally open the valve from port 1 to to port 1, and allowed from
screw-in cartridge solenoid port 2, or from port 2 to port 1 to port 2 when the
valve. port 1. coil force is overcome.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
2 Rated flow 114 L/min (30 USgpm)
Internal leakage less than 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-2 or C-12-2U
Add “U” after number if undercut is required. If undercut is not specified,
expect 10 psi@15 USgpm and 20 psi @ 30 USgpm higher pressure drop.
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,27 kg (0.59 lbs)
Seal kit 02-165889 (Buna-N), 02-165888 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 0 20 40 60 80 100
250

15
200

Pressure Drop - bar


Pressure Drop - psi

11
150
A
2 100 7

B
50 3
1
0
0 5 10 15 20 25 30
Application Note
Flow - USgpm (105 SUS oil @ 120°F)
This valve is pilot operated A - Port 1 to port 2 de-energized
and requires a minimum B - Port 2 to port 1 de-energized
flow of 1-2 L/min (0.3 - 0.5
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.

A-68 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV13-12-O

SV13 – 12 (V) – O (*) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV13 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size 7
Q - Spade terminals
Port Size W - Leadwire
12 - 12 size
CODE PORT SIZE HOUSING NUMBER N - Deutsch (DC only)
3 0 Cartridge only Y - Amp JR (DC only)
Seal material D - Metripack 150 male
Blank - Buna-N 4G 1/2” BSPP 02-175062 (DC only)
V - Viton® 4GU 1/2” BSPP 02-172512 J - Metripack 280 male
6G 3/4” BSPP 02-169665 (DC only)
4 Style
6GU 3/4” BSPP 02-162922
O - Normally open 10 Coil series
10T SAE 10 02-169744
5 Manual override option H - 10 series, 29 W
10TU SAE 10 02-169817
For coil dimensions see Section C.
Blank - No manual override 12T SAE 12 02-169782
P - Push type
S - Screw type 12TU SAE 12 02-169790 11 Special features
For valve dimensions with manual See section J for housings. 00 - None
override option installed see page A-152. (Only required if valve
8 Voltage rating 24A - 24VAC
has special features,
115A - 115VAC
00 - No coil omitted if “00.”)
230A - 230VAC
12D - 12VDC
12B - 12VDC/w diode*
24D - 24VDC
24B - 24VDC/w diode*
36D - 36VDC
*Optional arc suppression diode.
Dimensions
mm (inch)
29,6
(1.16)
Torque cartridge in steel
housing 102-115 Nm
(75-85 ft. lbs)

Note
When solenoid valve is Ø 38,9
ordered as cartridge only, (1.53) 22,2 (0.875) hex
nut is included.

60,3
(2.37)

31,75 (1.250) hex

WARNING 1.062" – 12 Thd.


• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 44,7
mum torque on valve tube (1.76)
nut. Over tightening may 2
cause valve failure. Ø 23,77 (.936)
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-69


SV3-12-C/CM/CR
Poppet type, normally
closed solenoid valve
(free reverse flow)

Description Operation
The SV3-12-C is a 2-way, In the de-energized posi- In the energized position,
2-position, poppet-type, tion, flow is blocked from the poppet lifts to allow
pilot-operated, normally port 2 to port 1 and free flow in either direction.
closed solenoid cartridge flow is allowed from port 1
valve. to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 114 L/min (30 USgpm)
2 Internal leakage (port 2 to port 1) less than 5 drops/min. max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Response times (100% rated voltage and flow) Energize:75 ms
De-Energize: 150 ms
Cavity C-12-2 or C-12-2U
Add “U” after number if undercut is required. If undercut is not specified,
expect 10 psi@15 USgpm and 20 psi @ 30 USgpm higher pressure drop.
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil 0,336 kg (0.74 lbs)
Seal kit 02-165889 (Buna-N), 02-165888 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 0 20 40 60 80 100 11 4
200 14

150 10
Pressure Drop - bar
Pressure Drop - psi

2
100
6
A
B
1 50

1
0
0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2 de-energized
B - Port 2 to port 1 energized

A-28 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV3-12-C

SV3 – 12 (V) – C (*) – (A) – *** – **** * – 00

1 2 3 4 5 6 7 8 9 10

1 Function 7 Port Size 9 Connector types

SV3 - Solenoid valve Blank - No coil


CODE PORT SIZE HOUSING NUMBER
G - ISO 4400 DIN 43650
2 Size Aluminum Steel Q - Spade terminals
12 - 12 size 0 Cartridge only W - Leadwire
4G 1/2” BSPP 02-161118 02-172062 N - Deutsch (DC only)
3 Seal material 4GU 1/2” BSPP 02-161116 02-172512 Y - Amp JR (DC only)
Blank - Buna-N D - Metripack 150 male
6G 3/4” BSPP 02-161117 02-169665
V - Viton® (DC only)
6GU 3/4” BSPP 02-161115 02-162922 J - Metripack 280 male
4 Style 10T SAE 10 02-160640 02-169744 (DC only)
C - Normally closed 10TU SAE 10 02-160641 02-169817 For coil part numbers and dimensions
see Section C.
12T SAE 12 02-160644 02-169782
5 Manual override option 12TU SAE 12 02-160645 02-169790
Blank - No manual override 10 Special features
See section J for housing details.
M - Knob type 00 - None
R - Cable type (Only required if valve
For valve dimensions with manual 8 Voltage rating 24A - 24VAC
has special features,
override option installed see page A-153. 115A - 115VAC
00 - No coil omitted if “00.”)
230A - 230VAC
12D - 12VDC
6 12B - 12VDC/w diode*
Valve housing material 24D - 24VDC Note
24B - 24VDC/w diode*
Omit for cartridge only 36D - 36VDC
*Optional arc suppression diode. Use J series, 23 W coils
A - Aluminum (standard)
S - Steel with this solenoid valve.

29,6
Dimensions
(1.16)
mm (inch)

Torque cartridge in housing


A - 81-95 Nm (60-70 ft. lbs) Ø 38,9
S - 102-115 Nm (75-85 ft. lbs) (1.53)

19,0 (0.75) hex


Note
When solenoid valve
is ordered as cartridge only, 59,8
coil nut is included. (2.36)

31,7 (1.25) hex


WARNING 1.063 " – 12 Thd.
• Maintain 5-8 Nm 44,7
(4-6 ft. lbs) maxi- (1.76) 2
mum torque on valve tube
nut. Over tightening may
1
cause valve failure. Ø 23,75 (0.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-29


SV13-16-O/OP/OS
Poppet type normally open
solenoid valve, 350 bar

Description Operation
The SV13-16-O is a 2-way, In the de-energized posi- flow is blocked from port 2
2-position, pilot operated, tion, this valve allows bi- to port 1 and allowed from
poppet type, normally open directional flow between port 1 to port 2, when the
screw-in cartridge solenoid port 1 and port 2. In the coil forces are overcome.
valve. energized position,

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 132 L/min (35 USgpm)
2
Internal leakage less than 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-16-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,39 kg (0.85 lbs)
Seal kit 565810 (Buna-N), 889609 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only
0 20 40 60 80 100 120
175
11
150

Pressure Drop - bar


Pressure Drop - psi

125 9

100 7
A B
2 75 5
50
3
1 25
1
0
0 5 10 15 20 25 30 35
Application Note Flow - USgpm (105 SUS oil @ 120°F)
This valve is pilot operated
and requires a minimum A - Port 2 to port 1 de-energized
flow of 1-2 L/min (0.3 - .5 B - Port 1 to port 2
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.

A-74 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV13-16-O

SV13 – 16 (V) – O (*) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV13 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
16 - 16 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 4G 1/2” BSPP 02-175106 (DC only)
V - Viton® J - Metripack 280 male
6G 3/4” BSPP 02-175107
(DC only)
4 Style 10T SAE 10 02-175104
O - Normally open 12T SAE 12 02-175105 10 Coil series

5 Manual override option


See section J for housings. H - 10 series, 29 W
For coil dimensions see Section C.
Blank - No manual override 24A - 24VAC
8 Voltage rating
P - Push type
S - Screw type 115A - 115VAC 11 Special features
00 - No coil
230A - 230VAC
For valve dimensions with manual 12D - 12VDC 00 - None
12B - 12VDC/w diode*
override option installed see page A-152. 24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)

29,6
Dimensions (1.16)
mm (inch)

Torque cartridge in steel


housing 136-149 Nm
(100-110 ft. lbs)
Ø 38,9
(1.53)
Note
When solenoid valve
22,2 (0.875) hex
is ordered as cartridge only,
nut is included.

64,1
(2.52)

38,1 (1.50) hex

1.312"– 12 Thd.
WARNING 44,6
(1.76)
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may Ø 28,54 (1.124)
cause valve failure. 1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-75


SV2-20-C/CM/CR
Poppet type, normally
closed solenoid valve
(free reverse flow)

Description Operation
The SV2-20-C is a 2-way, In the de-energized posi- In the energized position,
2-position, poppet type, tion, flow is blocked from bi-directional flow is
pilot operated, normally port 2 to port 1 and free allowed between port 1
closed screw-in cartridge flow is allowed from port 1 and port 2.
solenoid valve. to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 227 L/min (60 USgpm)
2
Internal leakage, port 2 to port 1 less than 5 drops/min. max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-20-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil 1,2 kg (2.70 lbs)
Seal kit 889615 (Buna-N), 889619 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only
0 40 80 120 160 200
200 14
180
12
160
140 10
Pressure Drop - psi

120 Pressure Drop - bar


8
100
80 6
2 B
60 4
A
40
2
20
1
0
0 10 20 30 40 50 60
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2 de-energized
B - Port 2 to port 1 energized

A-38 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV2-20-C

SV2 – 20 (V) – C (*) – *** – **** * – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port Size 8 Connector types

SV2 - Solenoid valve Blank - No coil


CODE PORT SIZE HOUSING NUMBER
G - ISO 4400 DIN 43650
2 Size 0 Cartridge only Q - Spade terminals
20 - 20 size 8B 1” BSPP 02-175464* W - Leadwire
16T SAE 16 566409* N - Deutsch (DC only)
3 Seal material 6G 3/4” BSPP 876732 Y - Amp JR (DC only)
Blank - Buna-N D - Metripack 150 male
8G 1” BSPP 876734
V - Viton® (DC only)
12H SAE 12 876733 J - Metripack 280 male
4 Style 16H SAE 16 876735 (DC only)
C - Normally closed *Light duty housing For coil part numbers and dimensions
See section J for housing details. see Section C.
5 Manual override option
7 Voltage rating 24A - 24VAC 9 Special features
Blank - No manual override
115A - 115VAC 00 - None
M - Knob type 00 - No coil
230A - 230VAC
R - Cable type 12D - 12VDC (Only required if valve
12B - 12VDC/w diode*
For valve dimensions with manual 24D - 24VDC has special features,
24B - 24VDC/w diode*
override option installed see page A-153. 36D - 36VDC omitted if “00.”)
*Optional arc suppression diode.

Note
Use J series, 23 W coils
Dimensions 29,6
with this solenoid valve.
mm (inch) (1.16)

Torque cartridge in alu-


minum housing 128-155
Nm (95-115 ft. lbs)

Ø 38,9
Note (1.53)
When solenoid valve is
ordered as cartridge only,
coil nut is included. 19,0 (0.75) hex

63,5
(2.50)

47,6 (1.87) hex

1.625" – 12 Thd.
WARNING 57,2
(2.25)
• Maintain 5-8 Nm 2
(4-6 ft. lbs) maxi-
mum torque on valve tube
nut. Over tightening may 1
cause valve failure. Ø 36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-39


SV3-20-O/OP/OS
Poppet type, normally
open solenoid valve

Description Operation
The SV3-20-O is a 2-way, In the de-energized posi- flow is blocked from port 2
2-position, poppet type, tion, this valve allows bi- to port 1 and allowed from
pilot operated, normally directional flow between port 1 to port 2 when coil
open, screw-in cartridge port 1 and port 2. In the forces are overcome.
solenoid valve. energized position,

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 227 L/min (60 USgpm)
2
Internal leakage, port 2 to port 1 less than 5 drops/min. max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Response times (100% rated voltage and flow) Energize: 75 ms
De-Energize: 150 ms
Cavity C-20-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil 1,2 kg (2.70 lbs)
Seal kit 889615 (Buna-N), 889619 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 0 75 150 225
150
9
125
Pressure Drop - bar
Pressure Drop - psi

100 7
?
2
75 5
B ?
50
1 3
A
25

0
0 20 40 60
Flow - USgpm (105 SUS oil @ 120°F)

A - Port 2 to port 1 and port 1 to port 2 de-energized


B - Port 1 to port 2 energized

A-76 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV3-20-O

SV3 – 20 (V) – O (*) – *** – **** * – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port Size 8 Connector types

SV3 - Solenoid valve Blank - No coil


CODE PORT SIZE HOUSING NUMBER
G - ISO 4400 DIN 43650
2 Size 0 Cartridge only Q - Spade terminals
8B 1” BSPP 02-175464* W - Leadwire
20 - 20 size
16T SAE 16 566409* N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 6G 3/4” BSPP 876732 D - Metripack 150 male
Blank - Buna-N 8G 1” BSPP 876734 (DC only)
V - Viton® 12H SAE 12 876733 J - Metripack 280 male
16H SAE 16 876735 (DC only)
4 Style
For coil dimensions see Section C.
C - Normally open *Light duty housings.
See pages J-3 and J-4 for housings.
9 Special features
5 Manual override option
00 - None
Blank - No manual override 7 24A - 24VAC
P - Push type Voltage rating (Only required if valve
115A - 115VAC has special features,
S - Screw type 00 - No coil
230A - 230VAC omitted if “00.”)
For valve dimensions with manual 12D - 12VDC
12B - 12VDC/w diode*
override option installed see page A-152. 24D - 24VDC
24B - 24VDC/w diode*
36D - 36VDC Note
*Optional arc suppression diode.
Use J series, 23 W coils
with this solenoid valve.
29,6
Dimensions
(1.16)
mm (inch)

Torque cartridge in
aluminum housing 128-155
Nm (95-115 ft. lbs)

Ø 38,9
Note (1.53)
When solenoid valve is
ordered as cartridge only,
coil nut is included. 19,0 (0.75) hex

76,2
(3.00)

47,6 (1.87) hex


1.625" – 12 Thd.
WARNING 57,2
(2.25)
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may 1
Ø 36,50 (1.437)
cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-77


SV13-20-O/OP/OS
Poppet type, normally open
solenoid valve

Description Operation
The SV13-20-O is a 2-way, In the de-energized posi- flow is blocked from port 2
2-position, pilot operated, tion, this valve allows bi- to port 1 and allowed from
poppet type, normally open directional flow between port 1 to port 2, when the
screw-in cartridge solenoid port 1 and port 2. In the coil forces are overcome.
valve. energized position,

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)*
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 227 L/min (60 USgpm)
2
Internal leakage, port 2 to port 1 less than 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-20-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,62 kg (1.37 lbs)
Seal kit 889615 (Buna-N), 889619 (Viton®)
Viton is a registered trademark of E.I. DuPont
*For application pressure over 280 bar (4000 psi) consult factory

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 0 40 80 120 160 200
175
11
150

Pressure Drop - bar


Pressure Drop - psi

125 9
A
2 100 7
B
75 5
50
1 3
25
1
0
?
0 10 20 30 40 50 60
Application Note Flow - USgpm (105 SUS oil @ 120°F)
This valve is pilot operated
and requires a minimum A - Port 2 to port 1 de-energized
flow of 1-2 L/min (0.3 - .5 B - Port 1 to port 2
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.

A-78 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV13-20-O

SV13 – 20 (V) – O (*) – (S) *** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV13 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
20 - 20 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER Y - Amp JR (DC only)
3 Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 6G 3/4” BSPP 02-175110 (DC only)
V - Viton® J - Metripack 280 male
8G 1” BSPP 02-175111
(DC only)
4 Style 12T SAE 12 02-175108
O - Normally open 16T SAE 16 02-175109 10 Coil series

5 Manual override option See section J for housings. H - 10 series, 29 W


For coil dimensions see Section C..
Blank - No manual override
8 Voltage rating 24A - 24VAC
P - Push type 9 Special features
115A - 115VAC
S - Screw type 00 - No coil
230A - 230VAC 00 - None
For valve dimensions with manual 12D - 12VDC
12B - 12VDC/w diode* (Only required if valve
override option installed see page A-152. 24D - 24VDC
24B - 24VDC/w diode* has special features,
36D - 36VDC
*Optional arc suppression diode.
omitted if “00.”)

29,6
(1.16)
Dimensions
mm (inch)

Torque cartridge in steel


housing 163-183 Nm
(120-135 ft. lbs)
Ø 38,9
(1.53)
Note
When solenoid valve 22,2 (0.875) hex
is ordered as cartridge only,

64,1
(2.52)

47,6 (1.875) hex

WARNING 1.625" – 12 Thd.


57,2
• Maintain 5-8 Nm (2.25)
(4-6 ft. lbs) maxi-
2
mum torque on valve tube
nut. Over tightening may
cause valve failure.
Ø 36,47 (1.436)
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-79


SV15-10-O/OP/OS
Poppet type normally open
solenoid valve, 350 bar

Description Operation
The SV15-10-O is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, flow from port 1 to flow is blocked from port 2
poppet type, normally open port 2 is restricted, while to port 1, and flow is
screw-in cartridge solenoid free flow is allowed from allowed from port 1 to port
valve. port 2 to port 1. 2, when coil forces are
overcome.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 45 L/min (12 USgpm)
2
Internal leakage less than 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only
0 8 15 23 30 38 45
100 7
Pressure Drop - psi

Pressure Drop - bar


75 5

50 3

2 25
2

1 0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
Application Note
This valve is pilot operated Port 2 to port 1 de-energized
and requires a minimum
flow of 1-2 L/min (0.3- 0.5
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.

A-62 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV15-10-O

SV15 – 10 (V) – O (*) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV15 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
10 - 10 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-175102 (DC only)
V - Viton® J - Metripack 280 male
3G 3/8” BSPP 02-175103
(DC only)
4 Style 6T SAE 6 02-175100
O - Normally open 8T SAE 8 02-175101 10 Coil series
See section J for housings. H - 10 series, 29 W
5 Manual override option
For coil dimensions see Section C.
Blank - No manual override 24A - 24VAC
8 Voltage rating
P - Push type
S - Screw type 115A - 115VAC 11 Special features
00 - No coil
230A - 230VAC
For valve dimensions with manual 12D - 12VDC 00 - None
12B - 12VDC/w diode*
override option installed see page A-152. 24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)

29,6
Dimensions (1.16)
mm (inch)

Torque cartridge in
steel housing 68-74 Nm
(50-55 ft. lbs)
Ø 38,9
Note (1.53)
When solenoid valve 22,2 (0.875) hex
is ordered as cartridge only,
nut is included.

57,8
(2.28)

25,4 (1.00) hex

0.875" – 14 Thd.
WARNING
• Maintain 5-8 Nm 31,7
(4-6 ft. lbs) maxi- (1.25)
mum torque on valve tube 2
nut. Over tightening may Ø 15,82 (0.623)
cause valve failure. 1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-63


SV11-10-C/CM
Poppet type, normally
closed solenoid valve,
350 bar

Description Operation
The SV11-10-C is a 2-way, 2- In the de-energized position, In the energized position,
position, pilot operated, this valve blocks flow from flow from port 1 to port 2
poppet type, normally port 2 to port 1 and free flow is restricted while free flow
closed, screw-in cartridge is allowed from port 1 to is allowed from port 2 to
solenoid valve. port 2. port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 45 L/min (12 USgpm)
2 Internal leakage, port 2 to port 1 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only

A - Port 1 to port 2 de-energized


B - Port 2 to port 1 energized

A-16 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV11-10-C

SV11 – 10 (V) – C (M) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 9
Connector types
6 Valve housing material
SV11 - Solenoid valve Blank - No coil
Blank - Cartridge only
G - ISO 4400 DIN 43650
2 S - Steel
Size Q - Spade terminals
10 - 10 size 7 W - Leadwire
Port Size N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Seal material Y - Amp JR (DC only)
0 Cartridge only D - Metripack 150 male
Blank - Buna-N
V - Viton® 2G 1/4” BSPP 02-175102 (DC only)
3G 3/8” BSPP 02-175103 J - Metripack 280 male
4 Style (DC only)
6T SAE 6 02-175100
C - Normally closed 8T SAE 8 02-175101 10 Coil series
5 Manual override option See section J for housing details. H - 10 series, 29 W
For coil part numbers and dimensions
Blank - No manual override
8 Voltage rating 24A - 24VAC see Section C.
M - Manual override
115A - 115VAC
For valve dimensions with manual 00 - No coil
230A - 230VAC 11 Special features
override option installed see page A-153. 12D - 12VDC
12B - 12VDC/w diode*
24D - 24VDC 00 - None
24B - 24VDC/w diode*
36D - 36VDC (Only required if valve
*Optional arc suppression diode.
has special features,

29,6
(1.16)

Dimensions
mm (inch)

Torque cartridge in Ø 38,9


steel housing 68-75 Nm (1.53)
(50-55 ft. lbs)

22,2 (0.875) hex


Note
When solenoid valve is
ordered as cartridge only,
coil nut is included.
57,8
(2.28)

WARNING 25,4 (1.00) hex

• Maintain 5-8 Nm 0.875" – 14 Thd.


(4-6 ft. lbs) maxi- 31,7
mum torque on valve tube (1.25)
nut. Over tightening may 2
cause valve failure. Ø 15,82 (.623)
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-17


SV12-10-C/CM
Poppet type, normally
closed solenoid valve,
350 bar

Description Operation
The SV12-10-C is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, this valve blocks flow flow from port 1 to port 2
poppet type, normally from port 2 to port 1 and is restricted while free flow
closed, screw-in cartridge free flow is allowed from is allowed from port 2 to
solenoid valve. port 1 to port 2. port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 23 L/min (6 USgpm)
2 Internal leakage 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Sectional View
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 8 15 23
100

Pressure Drop - bar


Pressure Drop - psi

75
A
50
3
B
2 25
1

1 0 2 4 6
?
Flow - USgpm (105 SUS oil @ 120°F)

A - Port 1 to port 2 de-energized


B - Port 2 to port 1 energized

A-22 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV12-10-C

SV12 – 10 (V) – C (M) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 9 Connector types


7 Port Size
SV12 - Solenoid valve Blank - No coil
CODE PORT SIZE HOUSING NUMBER G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
0 Cartridge only
10 - 10 size W - Leadwire
2G 1/4” BSPP 02-175102 N - Deutsch (DC only)
3 Seal material 3G 3/8” BSPP 02-175103 Y - Amp JR (DC only)
6T SAE 6 02-175100 D - Metripack 150 male
Blank - Buna-N (DC only)
V - Viton® 8T SAE 8 02-175101
J - Metripack 280 male
4 Style (DC only)
C - Normally closed 8 24A - 24VAC
Voltage rating 10 Coil series
115A - 115VAC
5 Manual override option 00 - No coil H - 10 series, 29 W
230A - 230VAC
12D - 12VDC For coil part numbers and dimensions
Blank - No manual override 12B - 12VDC/w diode*
24D - 24VDC see Section C.
M - Manual override 24B - 24VDC/w diode*
36D - 36VDC
For valve dimensions with manual *Optional arc suppression diode.
11 Special features
override option installed see page A-153.
00 - None
6 Valve housing material (Only required if valve
Blank - Cartridge only has special features,
S - Steel omitted if “00.”)
29,6
(1.16)

Dimensions
mm (inch)

Torque cartridge in
steel housing 68-75 Nm Ø 38,9
(50-55 ft. lbs) (1.53)
22,2 (0.875) hex
Note
When solenoid valve is
ordered as cartridge only,
coil nut is included.

57,8
(2.28)

25,4 (1.00) hex

WARNING 0.875"– 14 Thd.


31,7
• Maintain 5-8 Nm (1.25)
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may 1
Ø 15,82 (0.623)
cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-23


SV14-8-O/OM
Spool type, normally open
solenoid valve, 350 bar

Description Operation
The SV14-8-O is a 2-way, 2- In the de-energized posi- In the energized position,
position, spool type, direct tion, this valve allows bi- both ports are closed.
acting, normally open directional flow between
screw-in cartridge solenoid port 1 and port 2.
valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 13 L/min (3.5 USgpm)
2 Internal leakage, port 2 to port 1 140 cm3/min (8.5 in3/min) max. @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-8-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,11 kg (0.25 lbs)
Seal kit 02-165875 (Buna-N), 02-165877 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Cartridge only Flow - L/min (21,8 cSt oil @ 49°C)
0 2 4 6 8 10 12
150
10
125
8

Pressure Drop - bar


Pressure Drop - psi

100
2 6
75
4
50
1
25 2

0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Flow - USgpm (105 SUS oil @ 120°F)
Port 2 to port 1 de-energized
Port 1 to port 2 de-energized

A-82 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV14-8

SV14 – 8 (V) – O (M) – (S) ** – **** * P – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV14 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
8 - 8 size
CODE PORT SIZE HOUSING NUMBER
N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-160733 (DC only)
V - Viton® 3G 3/8” BSPP 02-160734 J - Metripack 280 male
(DC only)
4 Style 4T SAE 4 02-160736
O - Normally open 6T SAE 6 02-160737 10 Coil series
8T SAE 8 02-160738 P - 8 series, 23 W
5 Manual override option
See section J for housings. For coil dimensions see Section C.
Blank - No manual override
M - Manual override
8 Voltage rating 24A - 24VAC 11 Special features
For valve dimensions with manual override 115A - 115VAC
option installed see page A-153. 00 - No coil 00 - None
230A - 230VAC
12D - 12VDC (Only required if valve
12B - 12VDC/w diode*
24D - 24VDC has special features,
24B - 24VDC/w diode*
36D - 36VDC omitted if “00.”)
*Optional arc suppression diode.

26,0
(1.02)
Dimensions
mm (inch)

Torque cartridge in steel


or aluminum housing
34-41 Nm (25-30 ft. lbs)
Ø 31,7
(1.25)
Note
When solenoid valve is 15,8 (0.62) hex
ordered as cartridge only,
nut is included.
58,4
(2.30)

22,2 (0.87) hex

WARNING 0.750" – 16 Thd.

• Maintain 5-8 Nm 27,7


(4-6 ft. lbs) maxi- (1.09)
mum torque on valve tube 2
nut. Over tightening may Ø 12,6 (0.500)
cause valve failure.
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-83


SV14-8-C/CM
Spool type, normally
closed solenoid valve, 350
bar

Description Operation
The SV14-8-C is a 2-way, In the de-energized posi-
2-position, spool type, tion, flow is blocked in both
normally closed, screw-in directions. In the energized
cartridge solenoid valve. position, the spool lifts to
allow flow in either direc-
tion.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 11 L/min (3 USgpm)
2 Internal leakage, port 2 to port 1 140cm3 (8.5in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-8-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,11 kg (0.25 lbs)
Seal kit 02-160777 (Buna-N), 02-160778 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 2 4 6 8 10
100 8

6
Pressure Drop - psi

Pressure Drop -bar


75

4
2 50

2
25
1
0
0
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F)

Port 2 to port 1 or
port 1 to 2 (energized)

A-44 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV14-8-C

SV14 – 8 (V) – C (M) – (S) ** – **** * P – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV14 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
8 - 8 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER Y - Amp JR (DC only)
3 Seal material
0 Cartridge only D - Metripack 150 male
Blank - Buna-N (DC only)
V - Viton® 2G 1/4” BSPP 02-160733
J - Metripack 280 male
3G 3/8” BSPP 02-160734 (DC only)
4 Style 4T SAE 4 02-160736
C - Normally closed 6T SAE 6 02-160737 10 Coil Series

8T SAE 8 02-160738 P - 8 series, 23 W


5 Manual override option
See section J for housing details. For coil part numbers and dimensions
Blank - No manual override see Section C.
M - Manual override
For valve dimensions with manual 8 Voltage rating 24A - 24VAC
11 Special features
override option installed see page A-153. 115A - 115VAC
00 - No coil 00 - None
230A - 230VAC
12D - 12VDC
12B - 12VDC/w diode* (Only required if valve
24D - 24VDC
24B - 24VDC/w diode* has special features,
36D - 36VDC
*Optional arc suppression diode. omitted if “00.”)

26,0
(1.02)
Dimensions
mm (inch)

Torque cartridge in
steel housing 34-41 Nm
(25-30 ft. lbs)
Ø 31,7
Note (1.25)

When solenoid valve is 15,8 (0.62) hex


ordered as cartridge only,
coil nut is included.

58,4
(2.30)

WARNING 22,2 (0.87) hex

• Maintain 5-8 Nm 0.750" – 16 Thd.


(4-6 ft. lbs) maxi- 27,7
mum torque on valve tube (1.09)
nut. Over tightening may 2
cause valve failure.
Ø 12,6 (0.500) 1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-45


SV14-10-O/OM
Spool type, normally open
solenoid valve, 350 bar

Description Operation
The SV14-10-O is a 2-way, In the de-energized posi- In the energized position,
2-position, spool type, tion, this valve allows bi- both ports are closed.
direct acting, normally open directional flow between
screw-in cartridge solenoid port 1 and port 2.
valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 23 L/min (6 USgpm)
2 Internal leakage, port 2 to port 1 140 cm3/min. (8.5 in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 566806 (Buna-N), 889627 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 8 15 23
100 7

Pressure Drop - bar


Pressure Drop - psi

75 5

2 50
3

25
1
1

0 2 4 6
Flow - USgpm (105 SUS oil @ 120°F)
Port 2 to port 1 or
Port 1 to port 2 de-energized

A-86 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV14-10-O

SV14 – 10 (V) – O (M) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV14 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
10 - 10 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-175102 (DC only)
V - Viton® J - Metripack 280 male
3G 3/8” BSPP 02-175103
(DC only)
4 Style 6T SAE 6 02-175100
O - Normally open 8T SAE 8 02-175101 10 Coil series
See section J for housings. H - 10 series, 29 W
5 Manual override option
For coil dimensions see Section C..
Blank - No manual override
M - Manual override 8 Voltage rating 24A - 24VAC
For valve dimensions with manual 115A - 115VAC 11 Special features
Blank - No coil
override option installed see page A-153. 230A - 230VAC
12D - 12VDC 00 - None
12B - 12VDC/w diode*
24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)

Dimensions 29,6
mm (inch) (1.16)

Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs)

Ø 38,9
Note (1.53) 22,2 (0.875) hex
When solenoid valve is
ordered as cartridge only,
nut is included.

57,8
(2.28)

25,4 (1.00) hex

WARNING 0.875" – 14 Thd.


• Maintain 5-8 Nm 31,7
(4-6 ft. lbs) maxi- (1.25)
mum torque on valve tube 2
nut. Over tightening may Ø 15,82 (.623)
cause valve failure.
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-87


SBV11-8-O
Bi-directional, normally
open solenoid valve

Description Operation
The SBV11-8-O is a 2-way, In the de-energized posi-
2-position, bi-directional, tion, flow is allowed in both
normally open, poppet directions. In the energized-
type, screw-in cartridge position, flow is blocked in
solenoid valve. both directions.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 60 L/min (15 USgpm)
2 Internal leakage, port 1 to port 2 & port 2 to port 1 5 drops/min. max @ 350 bar (5000 psi)
when energized
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-8-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum or steel
Weight cartridge only 0,12 kg (0.26 lbs)
Seal kit 02-160777 (Buna-N), 02-160778 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 8 16 24 32 40 48 56
300 20

250
16
A Pressure Drop - bar
Pressure Drop - psi

200
12
2
150
8
1 100
B
4
50

0 0
1 3 5 7 9 11 13 15
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2
B - Port 2 to port 1

A-54 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SBV11-8-O

SBV11 – 8 (V) – O – (*) ** – **** * P – 00

1 2 3 4 5 6 7 8 9 10

1 Function 6 Port Size 8 Connector types

SBV11 - Solenoid Blank - No coil


CODE PORT SIZE HOUSING NUMBER G - ISO 4400 DIN 43650
bi-directional valve
Aluminum Steel Q - Spade terminals
2 Size 0 Cartridge only W - Leadwire
2G 1/4” BSPP 02-160727 02-160733 N - Deutsch (DC only)
8 - 8 size
Y - Amp JR (DC only)
3G 3/8” BSPP 02-160728 02-160734 D - Metripack 150 male
3 Seal material 4T SAE 4 02-160730 02-160736 (DC only)
Blank - Buna-N 6T SAE 6 02-160731 02-160737 J - Metripack 280 male
V - Viton® (DC only)
8T SAE 8 02-160732 02-160738
4 Style See section J for housings.
9 Coil series
O - Normally open
P - 8 series, 23 W
7 Voltage rating 24A - 24VAC
5 For coil dimensions see Section C.
Valve housing material 115A - 115VAC
00 - No coil
Blank - Cartridge only 230A - 230VAC
12D - 12VDC 10 Special features
A - Aluminum 12B - 12VDC/w diode*
24D - 24VDC 00 - None
S - Steel 24B - 24VDC/w diode*
36D - 36VDC
*Optional arc suppression diode. (Only required if valve
has special features,

Dimensions
mm (inch)
26,0
(1.02)
Torque cartridge in alu-
minum or steel housing
34-41 Nm (25-30 ft. lbs)

Note
Ø 31,7
When solenoid valve is (1.25) 15,8 (0.62) hex
ordered as cartridge only,
nut is included.

WARNING
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 58,4
mum torque on valve tube (2.30)
nut. Over tightening may
cause valve failure.

WARNING 22,2 (0.87) hex


Aluminum housings
• can be used for 27,7
pressures up to 210 2 (1.09)
bar (3000 psi) Steel housings
must be used for operating 0.750"– 16 Thd.
Ø 12,62 (0.497) 1
pressures above 210 bar
(3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-55


SBV11-10-C
Bi-directional, normally
closed solenoid valve

Description Operation
The SBV11-10-C is a In the de-energized posi-
2-way, 2-position, bi-direc- tion, flow is blocked in both
tional, normally closed, directions. In the energized
poppet type, screw-in position, flow is allowed in
cartridge, solenoid valve. both directions.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 76 L/min (20 USgpm)
2 Internal leakage 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum or steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 565806 (Buna-N), 889627 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 20 40 60
200
Pressure Drop - psi

175 12

Pressure Drop - bar


B 9
125
A 6
2 75
3
25
1
0 4 8 12 16 20

Flow - USgpm (105 SUS oil @ 120°F)

A - Port 1 to port 2
B - Port 2 to port 1

A-18 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SBV11-10-C

SBV11 – 10 (V) – C – (*) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10

1 Function 6 Port Size 8 Connector types


SBV11 - Solenoid CODE PORT SIZE HOUSING NUMBER Blank - No coil
bi-directional valve G - ISO 4400 DIN 43650
Aluminum Steel
Q - Spade terminals
2 Size 0 Cartridge only W - Leadwire
10 - 10 size 2G 1/4” BSPP 876702 02-175102 N - Deutsch (DC only)
3G 3/8” BSPP 876703 02-175103 Y - Amp JR (DC only)
3 Seal material 3B 3/8” BSPP 02-175462 – D - Metripack 150 male
Blank - Buna-N (DC only)
6H SAE 6 876700 – J - Metripack 280 male
V - Viton®
6T SAE 6 566151 02-175100 (DC only)
4 Style 8H SAE 8 876701 –
8T SAE 8 – 02-175101 9 Coil series
C - Normally closed
See section J for housing details. H - 10 series, 29 W
5 Valve housing material For coil part numbers and dimensions
Blank - Cartridge only see Section C.
7 Voltage rating 24A - 24VAC
A - Aluminum 115A - 115VAC
S - Steel 00 - No coil 10 Special features
230A - 230VAC
12D - 12VDC
12B - 12VDC/w diode* 00 - None
24D - 24VDC
24B - 24VDC/w diode* (Only required if valve
36D - 36VDC
*Optional arc suppression diode. has special features,
Dimensions omitted if “00.”)
mm (inch) 29,6
(1.16)
Torque cartridge in housing
A - 47-54 Nm (35-40 ft. lbs)
S - 68-75 Nm (50-55 ft. lbs)

Note Ø 38,9
(1.53)
When solenoid valve is
ordered as cartridge only, coil 22,2 (0.87) hex
nut is included.

WARNING
• Maintain 5-8 Nm 57,8
(4-6 ft. lbs) maxi- (2.28)
mum torque on valve tube
nut. Over tightening may
cause valve failure.
25,4 (1.00) hex
WARNING
Aluminum housings 31,7
• 0.875"– 14 Thd.
can be used for 2 (1.25)
pressures up to 210
bar (3000 psi) Steel housings 1
must be used for operating Ø 15,81 (0.622)
pressures above 210 bar
(3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-19


SBV11-10-O
Bi-directional, normally
open solenoid valve

Description Operation
The SBV11-10-O is a In the de-energized posi-
bi-directional, 2-way, 2-posi- tion, flow is allowed in both
tion, normally open, poppet directions. In the energized-
type, screw-in cartridge, position, flow is blocked in
solenoid valve. both directions.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 76 L/min (20 USgpm)
2 Internal leakage, port 1 to port 2 or port 2 to port 1 5 drops/min. max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Sectional View
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum or steel
Weight cartridge only 0,18 kg (0.39 lbs)
Seal kit 565806 (Buna-N), 889627 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 20 40 60
200

Pressure Drop - bar


Pressure Drop - psi

12
150

8
100

2 50 4

1 0 4 8 12 16 20
Flow - USgpm (105 SUS oil @ 120°F)
Port 1 to port 2 or
port 2 to port 1
de-energized

A-64 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SBV11-10-O

SBV11 – 10 (V) – O – (*) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10

1 Function 6 Port size 8 Connector types

SBV11 - Solenoid Blank - No coil


CODE PORT SIZE HOUSING NUMBER G - ISO 4400 DIN 43650
bi-directional valve
Aluminum Steel Q - Spade terminals
2 Size 0 Cartridge only W - Leadwire
N - Deutsch (DC only)
10 - 10 size 2G 1/4” BSPP 876702 02-175102
Y - Amp JR (DC only)
3G 3/8” BSPP 876703 02-175103 D - Metripack 150 male
3 Seal material
3B 3/8” BSPP 02-175462* – (DC only)
Blank - Buna-N J - Metripack 280 male
6H SAE 6 876700 –
V - Viton® (DC only)
6T SAE 6 566151* 02-175100
4 Style 8H SAE 8 876701 – 9 Coil series
O - Normally open 8T SAE 8 – 02-175101 H - 10 series, 29 W
*Light duty housings. For coil dimensions see Section C.
5 Valve housing material See section J for housings.
Blank - Cartridge only 10 Special features
A - Aluminum 7 Voltage rating 24A - 24VAC 00 - None
S - Steel 115A - 115VAC (Only required if valve
00 - No coil
230A - 230VAC has special features,
12D - 12VDC
12B - 12VDC/w diode* omitted if “00.”)
24D - 24VDC
24B - 24VDC/w diode*
36D - 36VDC
*Optional arc suppression diode.
Dimensions
mm (inch)
29,6
(1.16)
Torque cartridge in housing
A - 47-54 Nm (35-40 ft. lbs)
S - 68-75 Nm (50-55 ft. lbs)

Note
When solenoid valve is Ø 38,9
ordered as cartridge only, (1.53)
nut is included. 22,2 (0.87) hex

WARNING
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi-
mum torque on valve tube 57,8
nut. Over tightening may (2.28)
cause valve failure.

WARNING 25,4 (1.00) hex


Aluminum housings

can be used for 0.875"– 14 thd 31,7
pressures up to 210 bar (1.25)
(3000 psi) Steel housings 2
must be used for operating
pressures above 210 bar Ø 15,80 (0.622) 1
(3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-65


SV11-8-3/3M
3-way, 2-position spool
type solenoid valve,
350 bar

Description Operation
The SV11-8-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 1
spool type, screw-in car- from port 2 to port 1 while to port 3 while port 2 is
tridge solenoid valve. port 3 is blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 11 L/min (3 USgpm)
3 1 Internal leakage, combined port 2 and port 1 140 cm3/min. (8.5 in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-8-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,13 kg (0.28 lbs)
Seal kit 02-160755 (Buna-N), 02-160756 (Viton®)
Viton is a registered trademark of E.I. DuPont

Performance characteristics Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 0 2 4 6 8 10
125
8
100

Pressure Drop - bar


Pressure Drop - psi

Pressure drop vs. flow A 6


75
A - Port 1 to 2 and 1 to 3 B
B - Port 3 to 1 C 4
50
3
25 2

0 0
2
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F)
Flow - L/min (21,8 cSt oil @ 49°C)
1
0 2 4 6 8 10
Operating Limits 5000 A 350

A - Normally open & closed 4000 280


Pressure - bar
Pressure - psi

B - Selector 1 to 2 and 1 to 3
3000 210
B
2000 140

70
1000
0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Flow - USgpm (105 SUS oil @ 120°F)

A-90 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV11-8-3

SV11 – 8 (V) – 3 (M) – (S) ** – **** * P – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV11 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
8 - 8 size
CODE PORT SIZE HOUSING NUMBER N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-160743 (DC only)
V - Viton® 3G 3/8” BSPP 02-160744 J - Metripack 280 male
4T SAE 4 02-160745 (DC only)
4 Style
3 - 3-way, 2 position 6T SAE 6 02-160746 10 Coil series
See section J for housings. P - 8 series, 23 W
5 Manual override option
For coil dimensions see Section C.
Blank - No manual override 8 Voltage rating 24A - 24VAC
M - Manual override 115A - 115VAC
00 - No coil 11 Special features
For valve dimensions with manual 230A - 230VAC
12D - 12VDC 00 - None
override option installed see page A-153. 12B - 12VDC/w diode*
24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)

Dimensions 26,0
mm (inch) (1.02)

Torque cartridge in steel


or aluminum housing
34-41 Nm (25-30 ft. lbs)
Ø 31,7
19,1 (0.75) hex
Note (1.25)
When solenoid valve is
ordered as cartridge only,
nut is included.

58,4
(2.30)

22,2 (0.87) hex

0.750" – 16 Thd.
WARNING 40,6 3
• Maintain 5-8 Nm (1.60)
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may Ø 14,2 (0.559)
Ø 15,8 (0.622) 1
cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-91


SV11-10-3/3M
3-way, 2-position, spool
type solenoid valve,
350 bar

Description Operation
The SV11-10-3 is a 3-way, 2- In the de-energized posi- In the energized position,
position, direct acting, tion, this valve allows flow flow is allowed from port 1
spool type, screw-in car- from port 2 to port 1 while to port 3 while port 2 is
tridge solenoid valve. port 3 is blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 23 L/min (6 USgpm)
3 1 Internal leakage, port 2 to port 1 164 cm3/min. (10 in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,19 kg (0.42 lbs)
Seal kit 889624 (Buna-N), 889688 (Viton®)
Viton is a registered trademark of E.I. DuPont

Flow - L/min (21,8 cSt oil @ 49°C)


Pressure Drop Curves
0 8 15 23
Cartridge only 175
11
Pressure Drop - psi

Pressure Drop - bar


A 9
A - Port 3 to port 1 125
B - Port 1 to port 2 7
75 5
3 B
3
25
1
2
0 2 4 6
Flow - USgpm (105 SUS oil @ 120°F)
1
Operating Limits Flow - L/min (21,8 cSt oil @ 49°C)
0 4 8 11 15 18 23
A - Normally open, 5000 350
normally closed - A
selector 1 to 2 4000 280
Pressure - bar
Pressure - psi

B - Selector 1 to 2
3000 210

2000 140
B
1000 70

0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)

A-96 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV11-10-3

SV11 – 10 (V) – 3 (M) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV11 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
10 - 10 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-175127 (DC only)
V - Viton® J - Metripack 280 male
3G 3/8” BSPP 02-175128
(DC only)
4 Style 6T SAE 6 02-175124
3 - 3-way, 2 position 8T SAE 8 02-175125 10 Coil series

5 Manual override option


See section J for housings. H - 10 series, 29 W
For coil dimensions see Section C..
Blank - No manual override 8 24A - 24VAC
M - Manual override Voltage rating
115A - 115VAC 11 Special features
For valve dimensions with manual 00 - No coil
230A - 230VAC 00 - None
override option installed see page A-153. 12D - 12VDC
12B - 12VDC/w diode*
24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)

29,6
Dimensions (1.16)
mm (inch)

Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs) Ø 38,9
(1.53)
Note 22,2 (0.875) hex

When solenoid valve is


ordered as cartridge only,
nut is included.

57,8
(2.28)

25,4 (1.00) hex

0.875" – 14 Thd.
46,0
(1.81) 3
WARNING
2
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- Ø 15,82 (.623) 1
mum torque on valve tube
nut. Over tightening may Ø 17,42 (.686)
cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-97


SV1A/B-12-3
3-way, 2-position, spool
type solenoid valve

Description Operation
The SV1A/B-12-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 1 to port 2 while to port 1 while port 2 is
tridge solenoid valve. port 3 is blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2
Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV1A-12-3 38 L/min (10 USgpm)
3 1 Max. flow port 1 to port 2 - 27 L/min (7 USgpm)
SV1B-12-3 42 L/min (11 USgpm)
Sectional View Max. flow port 1 to port 2 - 34 L/min (9 USgpm)
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV1A-12-3 0,68 kg (1.5 lbs)
SV1B-12-3 0,86 kg (1.9 lbs)
Seal kit 9900171-000 (Buna-N), 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only
Flow - L/min
5 10 15 20 25 30 35
140
9
120
8
3 A
100 7
Pressure Drop - bar
Pressure Drop - psi

6
80
2
5

60 4
B
1 3
40

2
20
1

0
0 1 2 3 4 5 6 7 8 9 10
Flow - USgpm
A - Port 3 to port 1 energized
B - Port 1 to port 2 de-energized

A-100 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV1A/B-12-3

SV1 * – 12 * – 3P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV1 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV1A-12
A - 38 L/min (10 USgpm) A6G 3/4” BSPP 02-161816 R - R series (30W) used for
B - 42 L/min (11 USgpm) A12H SAE 12 02-160646 SV1B-12

3 Size 10
7 Voltage rating 8 Connector types Coil special features
12 - 12 size 00 - No coil Blank - No coil Blank - No coil
12D - 12VDC G - ISO 4400 DIN 43650 00 - No special feature
4 Seal Material
24D - 24VDC W - Leadwire
Blank - Buna-N 24A - 24VAC N - Deutsch (DC only) 11 Special features
V - Viton® 110A - 110VAC For coil dimensions see Section C.
115A - 115VAC 00 - None
5 Style 12B - 12VDC/w diode* (Only required if valve
3P - 3 way, push type manual 24B - 24VDC/w diode* has special features,
overide *Optional arc suppression diode. omitted if “00.”)
SF - Soft shift

SV1A-12-3 SV1B-12-3 50,3


Dimensions 48,7 (1.98)
mm (inch) (1.92)

Torque cartridge in
aluminum housing 81-95 43,5 (1.71) 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL
MANUAL OVERDRIVE
Note
OVERDRIVE
When solenoid valve is Torque Torque
ordered as cartridge only, 22-26 LB-IN 22-26 LB-IN
coil nut is included.

84,9 (3.34) 85,4 (3.36)

1.25” 1.25”
HEX HEX

1.062” -
WARNING 12 Thread

• Maintain 2.5-3 Nm 23,8


(1.8-2.2 ft. lbs) maxi- 3
(.94) 67,8 (2.67)
mum torque on valve tube
nut. Over tightening may 22,2
cause valve failure. 2
(.87)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-101


SV2A/B-12-3
3-way, 2-position, spool
type solenoid valve

Description Operation
The SV2A/B-12-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 2
spool type, screw-in car- from port 1 to port 3 while to port 1 while port 3 is
tridge solenoid valve. port 2 is blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV2A-12-3 30 L/min (8 USgpm)
Max. flow port 1 to port 3 - 27 L/min (7 USgpm)
3 1
SV2B-12-3 38 L/min (10 USgpm)
Sectional View Max. flow port 1 to port 3 - 34 L/min (9 USgpm)
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV2A-12-3 0,68 kg (1.5 lbs)
SV2B-12-3 0,86 kg (1.9 lbs)
Seal kit 9900171-000 (Buna-N), 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only Flow - L/min
5 10 15 20 25 30
10
140
3 9
120
8
A
2 100 7
Pressure Drop - psi

Pressure Drop - bar

6
80
1
5
60
4
B
40 3

2
20
1

0
0 1 2 3 4 5 6 7 8 9
Flow - USgpm
A - Port 2 to port 1 energized
B - Port 1 to port 3 de-energized

A-102 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV2A/B-12-3

SV2 * – 12 * – 3P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV2 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV2A-12
A - 30 L/min (8 USgpm) A6G 3/4” BSPP 02-161816 R - R series (30W) used for
B - 38 L/min (10 USgpm) A12H SAE 12 02-160646 SV2B-12

3 Size 10
7 Voltage rating 8 Connector types Coil special features
12 - 12 size 00 - No coil Blank - No coil Blank - No coil
12D - 12VDC G - ISO 4400 DIN 43650 00 - No special feature
4 Seal Material
24D - 24VDC W - Leadwire
Blank - Buna-N 24A - 24VAC N - Deutsch (DC only) 11 Special features
V - Viton® 110A - 110VAC For coil dimensions see Section C.
115A - 115VAC 00 - None
5 Style 12B - 12VDC/w diode* (Only required if valve
3P - 3 way, push type manual 24B - 24VDC/w diode* has special features,
overide *Optional arc suppression diode. omitted if “00.”)
SF - Soft shift

SV2A-12-3 SV2B-12-3 50,3


Dimensions 48,7 (1.98)
mm (inch) (1.92)

Torque cartridge in
aluminum housing 81-95 43,5 (1.71) 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL
MANUAL OVERDRIVE
Note OVERDRIVE
When solenoid valve is Torque Torque
ordered as cartridge only, 22-26 LB-IN 22-26 LB-IN
coil nut is included.

84,9 (3.34) 85,4 (3.36)

1.25” 1.25”
HEX HEX

1.062” -
WARNING 12 Thread

• Maintain 2.5-3 Nm 23,8


(1.8-2.2 ft. lbs) maxi- 3
(.94) 67,8 (2.67)
mum torque on valve tube
nut. Over tightening may 22,2
2
cause valve failure. (.87)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-103


SV4A/B-12-3
3-way, 2-position, spool
type solenoid valve

Description Operation
The SV4A/B-12-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 2 to port 1 while to port 2 while port 1 is
tridge solenoid valve. port 3 is blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV4A-12-3 34 L/min (9 USgpm)
SV4B-12-3 42 L/min (11 USgpm)
3 1
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Sectional View Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV4A-12-3 0,68 kg (1.5 lbs)
SV4B-12-3 0,86 kg (1.9 lbs)
Seal kit 9900171-000 (Buna-N), 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only Flow - L/min
5 10 15 20 25 30 35 40
180
12
160 11

3 140 10

A 9
120
8
Pressure Drop - psi

Pressure Drop - bar

2 7
100
6
80
1 5
60 B 4

40 3
2
20
1
0
0 1 2 3 4 5 6 7 8 9 10 11
Flow - USgpm
A - Port 3 to port 2 energized
B - Port 2 to port 1 de-energized

A-104 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV4A/B-12-3

SV4 * – 12 * – 3P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV4 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV4A-12
A - 34 L/min (9 USgpm) A6G 3/4” BSPP 02-161816 R - R series (30W) used for
B - 42 L/min (11 USgpm) A12H SAE 12 02-160646 SV4B-12

3 Size 7 8 Connector types 10


Voltage rating Coil special features
12 - 12 size 00 - No coil Blank - No coil Blank - No coil
12D - 12VDC G - ISO 4400 DIN 43650 00 - No special feature
4 Seal Material W - Leadwire
24D - 24VDC
Blank - Buna-N 24A - 24VAC N - Deutsch (DC only)
11 Special features
V - Viton® 110A - 110VAC For coil dimensions see Section C.
115A - 115VAC 00 - None
5 Style 12B - 12VDC/w diode* (Only required if valve
3P - 3 way, push type manual 24B - 24VDC/w diode* has special features,
overide *Optional arc suppression diode. omitted if “00.”)
SF - Soft shift

SV4A-12-3 SV4B-12-3 50,3


Dimensions 48,7 (1.98)
mm (inch) (1.92)

Torque cartridge in
aluminum housing 81-95 43,5 (1.71) 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL
MANUAL OVERDRIVE
Note
OVERDRIVE
When solenoid valve is Torque Torque
ordered as cartridge only, 22-26 LB-IN 22-26 LB-IN
coil nut is included.

84,9 (3.34) 85,4 (3.36)

1.25” 1.25”
HEX HEX

1.062” -
WARNING 12 Thread

• Maintain 2.5-3 Nm 23,8


(1.8-2.2 ft. lbs) maxi- 3
(.94) 67,8 (2.67)
mum torque on valve tube
nut. Over tightening may 22,2
cause valve failure. 2
(.87)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-105


SV12-8-4/4M
4-way, 2-position spool
type solenoid valve,
350 bar

Description Operation
The SV12-8-4 is a 4-way, In the de-energized position
2-position, direct acting, all ports are blocked. In the
spool type, screw-in car- energized position, flow is
tridge solenoid valve. allowed from port 3 to port
4 and from port 2 to port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 13 L/min (3.5 USgpm)
3 1
Internal leakage, port 2 to port 1 82 cm3/min. (5 in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-8-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,14 kg (0.30 lbs)
Seal kit 02-160757 (Buna-N), 02-160758 (Viton®)
Viton is a registered trademark of E.I. DuPont

Performance Characteristics
Cartridge only

Pressure drop vs. flow Operating Limits


A - Port 3 to port 4 A - Port 2 to port 1
4 B - Port 2 to port 1 B - Port 3 to port 4

Flow - L/min (21,8 cSt oil @ 49°C)


3 Flow - L/min (21,8 cSt oil @ 49°C)
0 2 4 6 8 10 0 2 4 6 8 10
125 350
5000 A
8
Pressure Drop - bar
Pressure Drop - psi

2
100 280
4000
Pressure - bar
Pressure - psi

A 6
1 75
3000 210
B 4
50 140
2000
2 B
25 70
1000
0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)

A-112 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV12-8-4

SV12 – 8 (V) – 4 (M) – (S) ** – **** * P – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV12 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
8 - 8 size
CODE PORT SIZE HOUSING NUMBER N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-160751 (DC only)
V - Viton® 3G 3/8” BSPP 02-160752 J - Metripack 280 male
4T SAE 4 02-160753 (DC only)
4 Style
4 - 4-way, 2 position 6T SAE 6 02-160754 10 Coil series
See page J-13 for housings. P - 8 series, 23 W
5 Manual override option
For coil dimensions see Section C.
Blank - No manual override 8 24A - 24VAC
M - Manual override Voltage rating
00 - No coil 115A - 115VAC 11 Special features
For valve dimensions with manual override
12D - 12VDC 230A - 230VAC
option installed see page A-153. 12B - 12VDC/w diode* 00 - None
24D - 24VDC
24B - 24VDC/w diode* (Only required if valve
36D - 36VDC
*Optional arc suppression diode. has special features,
omitted if “00.”)

29,6
Dimensions (1.16)
mm (inch)

Torque cartridge in
aluminum or steel housing Ø 38,9
34-41 Nm (25-30 ft. lbs) (1.53)

Note 15,8 (0.62) hex


When solenoid valve is
ordered as cartridge only, 58,4
nut is included. (2.30)
22,2 (0.87) hex
0.750"– 16 Thd.
4
54,5
(2.15) 3
2
Ø 12,6 (0.500)
Ø 14,2 (0.559) 1
WARNING Ø 15,8 (0.622)

• Maintain 5-8 Nm
(4-6 ft. lbs) maxi-
mum torque on valve tube
nut. Over tightening may
cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-113


SV3-10-4/4M/4R
4-way, 2-position spool
type solenoid valve

Description Operation
The SV3-10-4 is a 4-way, In the de-energized posi- In the energized position all
2-position, direct acting, tion, port 3 is open to port 4 ports are blocked.
spool type, screw-in car- and port 2 is open to port 1.
tridge solenoid valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
3 1
Internal leakage 164 cm3/min (10 in3/min) max. @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil 0,44 kg (0.96 lbs)
Seal kit 889625 (Buna-N), 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only
0 5 10 15 20
90
6
75
4
5

Pressure Drop - bar


Pressure Drop - psi

60
3 4
45
B 3
A
2 30
2
15 1
1
0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 3 to port 4
B - Port 1 to port 2

A-120 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV3-10-4

SV3 – 10 (V) – 4 (*) – ** – **** * – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port Size 8 Connector types

SV3 - Solenoid valve Blank - No coil


CODE PORT SIZE HOUSING NUMBER
G - ISO 4400 DIN 43650
2 Size 0 Cartridge only Q - Spade terminals
3B 3/8” BSPP 02-179705* W - Leadwire
10 - 10 size
6T SAE6 566161* N - Deutsch (DC only)
3 Seal material Y - Amp JR (DC only)
2G 1/4” BSPP 876709 D - Metripack 150 male
Blank - Buna-N 3G 3/8” BSPP 876715 (DC only)
V - Viton® 6H SAE 6 876708 J - Metripack 280 male
8H SAE 8 876713 (DC only)
4 Style For coil dimensions see Section C.
4 - 4-way, 2 position *Light duty housing.
See section J for housings. 9
5
Special features
Manual override option
00 - None
Blank - No manual override 7 Voltage rating 24A - 24VAC
115A - 115VAC (Only required if valve
M - Knob type
00 - No coil has special features,
R - Cable type 230A - 230VAC
12D - 12VDC omitted if “00.”)
For valve dimensions with manual 12B - 12VDC/w diode*
24D - 24VDC
override option installed see page A-153. 24B - 24VDC/w diode*
36D - 36VDC Note
*Optional arc suppression diode.
Use J series, 23 W coils

Dimensions 29,6
mm (inch) (1.16)

Torque cartridge in
aluminum housing 47-54
Nm (35-40 ft. lbs) Ø 38,9
(1.53)

Note 19,0 (0.75) hex


When solenoid valve is
ordered as cartridge only,
coil nut is included.
57,1
(2.25)

25,4 (1.00) hex

0.875 "– 14 Thd.


4
62,0
(2.44)
3
WARNING
• Maintain 5-8 Nm 2
(4-6 ft. lbs) maxi-
mum torque on valve tube
nut. Over tightening may 1
Ø 15,80 (0.622)
cause valve failure. Ø 17,40 (0.685)
Ø 18,97 (0.747)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-121


SV4-10-4/4M/4R
4-way, 2-position spool
type solenoid valve

Description Operation
The SV4-10-4 is a 4-way, In the de-energized posi- In the energized position
2-position, direct acting, tion, flow is allowed port 3 is open to port 4 and
spool type, screw-in car- between port 1 and port 4 port 2 is open to port 1.
tridge solenoid valve. while port 2 and port 3 are
blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
3 1
Internal leakage 164 cm3/min (10 in3/min) max. @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil 0,44 kg (0.96 lbs)
Seal kit 889625 (Buna-N), 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only
0 5 10 15 20
90
6
75
4 5

Pressure Drop - bar


Pressure Drop - psi

60
4
3
45
3
A B
30 2
2
15 1

1 0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 3 to port 4
B - Port 1 to port 2

A-122 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV4-10-4

SV4 – 10 (V) – 4 (*) – ** – **** * – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port Size 8 Connector types

SV4 - Solenoid valve Blank - No coil


CODE PORT SIZE HOUSING NUMBER
G - ISO 4400 DIN 43650
2 Size 0 Cartridge only Q - Spade terminals
3B 3/8” BSPP 02-179705* W - Leadwire
10 - 10 size
6T SAE6 566161* N - Deutsch (DC only)
3 Seal material Y - Amp JR (DC only)
2G 1/4” BSPP 876709 D - Metripack 150 male
Blank - Buna-N 3G 3/8” BSPP 876715 (DC only)
V - Viton® 6H SAE 6 876708 J - Metripack 280 male
(DC only)
4 Style 8H SAE 8 876713
For coil dimensions see Section C.
4 - 4-way, 2 position *Light duty housing.
See section J for housings. 9
5
Special features
Manual override option
00 - None
Blank - No manual override 7 Voltage rating 24A - 24VAC
115A - 115VAC (Only required if valve
M - Knob type 00 - No coil
230A - 230VAC has special features,
R - Cable type 12D - 12VDC
12B - 12VDC/w diode* omitted if “00.”)
For valve dimensions with manual 24D - 24VDC
override option installed see page A-153. 24B - 24VDC/w diode*
36D - 36VDC
*Optional arc suppression diode. Note
Use J series, 23 W coils
with this solenoid valve.
29,6
Dimensions
(1.16)
mm (inch)

Torque cartridge in
aluminum housing 47-54
Nm (35-40 ft. lbs) Ø 38,9
(1.53)

Note 19,0 (0.75) hex


When solenoid valve is
ordered as cartridge only,
nut is included.
57,1
(2.25)

25,4 (1.00) hex

0.875" – 14 Thd.
4
62,0
(2.44)
3
WARNING
Maintain 5-8 Nm 2

(4-6 ft. lbs) maxi-
mum torque on valve tube 1
Ø 15,80 (0.622)
nut. Over tightening may
cause valve failure. Ø 17,40 (0.685)
Ø 18,97 (0.747)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-123


SV5-10-4/4M/4R
4-way, 2-position spool
type solenoid valve

Description Operation
The SV5-10-4 is a 4-way, In the de-energized posi-
2-position, direct acting, tion, all ports are blocked.
spool type, screw-in In the energized position
cartridge solenoid valve. port 2 is open to port 3 and
port 1 is open to port 4.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
3 1
Internal leakage 164 cm3/min (10 in3/min) max. @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil 0,44 kg (0.96 lbs)
Seal kit 889625 (Buna-N), 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)


Cartridge only 0 5 10 15 20
90 6

75 5

Pressure Drop - bar


Pressure Drop - psi

4
60 4
3 A
45 3
B
30 2
2
15 1

1 0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 4
B - Port 3 to port 2

A-124 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV5-10-4

SV5 – 10 (V) – 4 (*) – ** – **** * – 00

1 2 3 4 5 6 7 8 9

1 Function 6 Port Size 8 Connector types

SV5 - Solenoid valve Blank - No coil


CODE PORT SIZE HOUSING NUMBER
G - ISO 4400 DIN 43650
2 Size 0 Cartridge only Q - Spade terminals
3B 3/8” BSPP 02-179705* W - Leadwire
10 - 10 size
6T SAE6 566161* N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 2G 1/4” BSPP 876709 D - Metripack 150 male
Blank - Buna-N 3G 3/8” BSPP 876715 (DC only)
V - Viton® 6H SAE 6 876708 J - Metripack 280 male
(DC only)
4 Style 8H SAE 8 876713
For coil dimensions see Section C.
4 - 4-way, 2 position *Light duty housing.
See section J for housings. 9 Special features
5 Manual override option
00 - None
Blank - No manual override 7 Voltage rating 24A - 24VAC
115A - 115VAC (Only required if valve
M - Knob type 00 - No coil
230A - 230VAC has special features,
R - Cable type 12D - 12VDC
12B - 12VDC/w diode* omitted if “00.”)
For valve dimensions with manual 24D - 24VDC
override option installed see page A-153. 24B - 24VDC/w diode*
36D - 36VDC Note
*Optional arc suppression diode.
Use J series, 23 W coils
29,6 with this solenoid valve.
Dimensions (1.16)
mm (inch)

Torque cartridge in
aluminum housing 47-54 Ø 38,9
Nm (35-40 ft. lbs) (1.53)
19,0 (0.75) hex
Note
When solenoid valve is
ordered as cartridge only,
coil nut is included. 57,1
(2.25)

25,4 (1.00) hex

0.875" – 14 Thd.
4
62,0
(2.44) 3
WARNING
Maintain 5-8 Nm 2

(4-6 ft. lbs) maxi-
mum torque on valve tube Ø 15,80 (0.622) 1
nut. Over tightening may
Ø 17,40 (0.685)
cause valve failure.
Ø 18,97 (0.747)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-125


SV2A/B-12-4
4-way, 2-position, spool
type solenoid valve

Description Operation
The SV2A/B-12-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, all ports are blocked. port 3 is open to port 4 and
spool type, screw-in car- port 2 is open to port 1.
tridge solenoid valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
4 2 Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV2A-12-4 34 L/min (9 USgpm)
SV2B-12-4 42 L/min (11 USgpm)
3 1
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Sectional View Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV2A-12-4 0,68 kg (1.5 lbs)
SV2B-12-4 0,86 kg (1.9 lbs)
Seal kit 2160979 (Buna-N), 2160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only
Flow - L/min
5 10 15 20 25 30 35 40
100

6
80 A
4
5

60 B
Pressure Drop - bar
Pressure Drop - psi

4
3

3
40
2
2

20
1 1

0
0 1 2 3 4 5 6 7 8 9 10 11
Flow - USgpm
A - Port 2 to port 1
B - Port 3 to port 4

A-128 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV2A/B-12-4

SV2 * – 12 * – 4P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV2 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV2A-12
A - 34 L/min (9 USgpm) A6G 3/4” BSPP 5986432-001 R - R series (30W) used for
B - 42 L/min (11 USgpm) A10H SAE 10 5986434-001 SV2B-12
A12H SAE 12 5986436-001
3 Size 10 Coil special features
7 Voltage rating 8 Connector types
12 - 12 size Blank - No coil
00 - No coil Blank - No coil
00 - No special feature
4 Seal Material 12D - 12VDC G - ISO 4400 DIN 43650
Blank - Buna-N 24D - 24VDC W - Leadwire
24A - 24VAC For coil dimensions see Section C. 11 Special features
V - Viton®
110A - 110VAC 00 - None
5 Style 115A - 115VAC (Only required if valve
4P - 4 way, push type manual 12B - 12VDC/w diode* has special features,
overide 24B - 24VDC/w diode* omitted if “00.”)
*Optional arc suppression diode. SF - Soft shift

SV2A-12-4 48,7 SV2B-12-4 50,3


Dimensions (1.92) (1.98)
mm (inch)

Torque cartridge in 43,5 (1.71)


aluminum housing 81-95 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL MANUAL
OVERDRIVE OVERDRIVE
Note Torque
Torque 22-26 LB-IN
When solenoid valve is 22-26 LB-IN
ordered as cartridge only,
coil nut is included.

85,4 (3.36)
84,9 (3.34)

1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread

WARNING 4 Ø 23,8 (.935)


• Maintain 2.5-3 Nm 90,9 (3.58)
(1.8-2.2 ft. lbs) maxi-
3 Ø 22,1 (.872)
mum torque on valve tube
nut. Over tightening may
cause valve failure.
2 Ø 20,6 (.810)

1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-129
SV3A/B-12-4
4-way, 2-position, spool
type solenoid valve

Description Operation
The SV3A/B-12-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, port 3 is open to port all ports are blocked.
spool type, screw-in car- 4 and port 2 is open to port
tridge solenoid valve. 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
4 2 Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV3A-12-4 46 L/min (12 USgpm)
SV3B-12-4 53 L/min (14 USgpm)
3 1
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Sectional View Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV3A-12-4 0,68 kg (1.5 lbs)
SV3B-12-4 0,86 kg (1.9 lbs)
Seal kit 2160979 (Buna-N), 2160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only
Flow - L/min
5 10 15 20 25 30 35 40 45 50
160 11

10
140
4 9
A
120
8

7
Pressure Drop - bar

100
Pressure Drop - psi

3
6
80
5
B
2 60
4

40 3
1 2
20
1

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow - USgpm
A - Port 3 to port 4
B - Port 2 to port 1

A-130 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV3A/B-12-4

SV3 * – 12 * – 4P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV3 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV3A-12
A - 46 L/min (12 USgpm) A6G 3/4” BSPP 5986432-001 R - R series (30W) used for
B - 53 L/min (14 USgpm) A10H SAE 10 5986434-001 SV3B-12
A12H SAE 12 5986436-001
3 Size 10 Coil special features
7 Voltage rating 8 Connector types
12 - 12 size Blank - No coil
00 - No coil Blank - No coil 00 - No special feature
4 Seal Material G - ISO 4400 DIN 43650
12D - 12VDC
Blank - Buna-N 24D - 24VDC W - Leadwire
N - Deutsch (DC only) 11 Special features
V - Viton® 24A - 24VAC
110A - 110VAC For coil dimensions see Section C. 00 - None
5 Style 115A - 115VAC (Only required if valve
4P - 4 way, push type manual 12B - 12VDC/w diode* has special features,
overide 24B - 24VDC/w diode* omitted if “00.”)
*Optional arc suppression diode. SF - Soft shift

SV3A-12-4 48,7 SV3B-12-4 50,3


Dimensions (1.92) (1.98)
mm (inch)

Torque cartridge in 43,5 (1.71)


aluminum housing 81-95 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL MANUAL
OVERDRIVE OVERDRIVE
Note Torque
Torque 22-26 LB-IN
When solenoid valve is 22-26 LB-IN
ordered as cartridge only,
coil nut is included.

85,4 (3.36)
84,9 (3.34)

1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread

WARNING 4 Ø 23,8 (.935)


• Maintain 2.5-3 Nm
90,9 (3.58)
(1.8-2.2 ft. lbs) maxi-
3 Ø 22,1 (.872)
mum torque on valve tube
nut. Over tightening may
cause valve failure.
2 Ø 20,6 (.810)

1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-131
SV5A/B-12-4
4-way, 2-position, spool
type solenoid valve

Description Operation
The SV5A/B-12-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, all ports are blocked. port 3 is open to port 2 and
spool type, screw-in car- port 4 is open to port 1.
tridge solenoid valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
4 2 Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV5A-12-4 46 L/min (12 USgpm)
SV5B-12-4 53 L/min (14 USgpm)
3 1
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Sectional View Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV5A-12-4 0,68 kg (1.5 lbs)
SV5B-12-4 0,86 kg (1.9 lbs)
Seal kit 2160979 (Buna-N), 2160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only
Flow - L/min (21,8 cst Oil @49° C)
5 10 15 20 25 30 35 40 45 50 55
150 10
4 140
9
130
120 8
3 110
7
Pressure Drop (psi)

Pressure Drop (bar)

100
90 6
2 80 A 5
70
60 4
1 50 B 3
40
30 2
20
1
10
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow - US gpm (105 SUS Oil @ 120°F)
A - Port 3 to port 2
B - Port 4 to port 1

A-132 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV5A/B-12-4

SV5 * – 12 * – 4P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV5 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV5A-12
A - 46 L/min (12 USgpm) A6G 3/4” BSPP 5986432-001 R - R series (30W) used for
B - 53 L/min (14 USgpm) A10H SAE 10 5986434-001 SV5B-12
A12H SAE 12 5986436-001
3 Size 10 Coil special features
7 Voltage rating 8 Connector types
12 - 12 size Blank - No coil
00 - No coil Blank - No coil 00 - No special feature
4 Seal Material 12D - 12VDC G - ISO 4400 DIN 43650
Blank - Buna-N 24D - 24VDC W - Leadwire
N - Deutsch (DC only) 11 Special features
V - Viton® 24A - 24VAC
110A - 110VAC For coil dimensions see Section C. 00 - None
5 Style 115A - 115VAC (Only required if valve
4P - 4 way, push type manual 12B - 12VDC/w diode* has special features,
overide 24B - 24VDC/w diode* omitted if “00.”)
*Optional arc suppression diode. SF - Soft shift

SV5A-12-4 48,7 SV5B-12-4 50,3


Dimensions
(1.92) (1.98)
mm (inch)

Torque cartridge in 43,5 (1.71)


aluminum housing 81-95 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL MANUAL
OVERDRIVE OVERDRIVE
Note Torque
Torque 22-26 LB-IN
When solenoid valve is 22-26 LB-IN
ordered as cartridge only,
coil nut is included.

85,4 (3.36)
84,9 (3.34)

1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread

WARNING 4 Ø 23,8 (.935)


• Maintain 2.5-3 Nm
90,9 (3.58)
(1.8-2.2 ft. lbs) maxi-
mum torque on valve tube 3 Ø 22,1 (.872)
nut. Over tightening may
cause valve failure.
2 Ø 20,6 (.810)

1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-133
SV7A/B-12-4
4-way, 2-position, spool
type solenoid valve

Description Operation
The SV7A/B-12-4 is a 4-way, In the energized position, In the de-energized position,
2-position, direct acting, port 3 is open to port 4 and port 3 is open to port 2 and
spool type, screw-in car- port 2 is open to port 1. port 4 is open to port 1.
tridge solenoid valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow SV7A-12-4 38 L/min (10 USgpm)
SV7B-12-4 46 L/min (12 USgpm)
3 1
Internal leakage 300 cm3/min (21.5 in3/min) max. @ 210 bar (3000 psi)
Sectional View Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Aluminum
Weight including coil SV7A-12-4 0,68 kg (1.5 lbs)
SV7B-12-4 0,86 kg (1.9 lbs)
Seal kit 2160979 (Buna-N), 2160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves


Cartridge only
Flow - L/min (21,8 cst Oil @49° C)
5 10 15 20 25 30 35 40 45
4 150 10
140
9
130
3 120 8
110
7
Pressure Drop (psi)

Pressure Drop (bar)

100
2 90 6
80
A
5
70
1 60 B 4
50
3
40
30 2
20
1
10
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12
Flow - US gpm (105 SUS Oil @ 120°F)
A - Port 2 to port 1, port 3 to port 4
B - Port 3 to port 4, port 3 to port 2

A-134 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV7A/B-12-4

SV7 * – 12 * – 4P – **** – **** * * ** – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size 9 Coil types


SV7 - Solenoid valve CODE PORT SIZE HOUSING NUMBER
Blank - No coil
L - L series (30W EN 490)
2 Max Flow 0 Cartridge only used for SV7A-12
A - 38 L/min (10 USgpm) A6G 3/4” BSPP 5986432-001 R - R series (30W) used for
B - 46 L/min (12 USgpm) A10H SAE 10 5986434-001 SV7B-12
A12H SAE 12 5986436-001
3 Size 10 Coil special features
7 Voltage rating 8 Connector types
12 - 12 size Blank - No coil
00 - No coil Blank - No coil 00 - No special feature
4 Seal Material G - ISO 4400 DIN 43650
12D - 12VDC
Blank - Buna-N 24D - 24VDC W - Leadwire
11 Special features
V - Viton® 24A - 24VAC N - Deutsch (DC only)
110A - 110VAC For coil dimensions see Section C. 00 - None
5 Style 115A - 115VAC (Only required if valve
4P - 4 way, push type manual 12B - 12VDC/w diode* has special features,
overide 24B - 24VDC/w diode* omitted if “00.”)
*Optional arc suppression diode. SF - Soft shift

Dimensions SV7A-12-4 48,7 SV7B-12-4 50,3


mm (inch)
(1.92) (1.98)

Torque cartridge in
aluminum housing 81-95 43,5 (1.71)
45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL MANUAL
OVERDRIVE OVERDRIVE
Note Torque
Torque 22-26 LB-IN
When solenoid valve is 22-26 LB-IN
ordered as cartridge only,
coil nut is included.

85,4 (3.36)
84,9 (3.34)

1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread

WARNING 4 Ø 23,8 (.935)


• Maintain 2.5-3 Nm
(1.8-2.2 ft. lbs) maxi- 90,9 (3.58)
mum torque on valve tube 3 Ø 22,1 (.872)
nut. Over tightening may
cause valve failure.
2 Ø 20,6 (.810)

1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-135
SV11-8-4/4M
4-way, 2-position spool
type solenoid valve,
350 bar

Description Operation
The SV11-8-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 3 to port 2 and to port 4 and from port 2 to
tridge solenoid valve. from port 4 to port 1. port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 11 L/min (3 USgpm)
3 1
Internal leakage (per land) 82 cm3/min. (5 in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Sectional View Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-8-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,14 kg (0.30 lbs)
Seal kit 02-160757 (Buna-N), 02-160758 (Viton®)
Viton is a registered trademark of E.I. DuPont

Performance Characteristics
Cartridge only

Pressure drop vs. flow Operating Limits


4 A - Port 3 to 4 and 3 to 2 A - Port 2 to1, 4 to 1, and 3 to 2
B - Port 4 to 1 B - Port 3 to 4
3 C - Port 2 to 1

Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)
2 0 2 4 6 8 10
0 2 4 6 8 10 5000 350
125 A
1 280
Pressure Drop - bar

8
Pressure Drop - psi

4000
100
Pressure - bar
Pressure - psi

A 6 3000 210
75
B
B 2000 140
50 4

C 70
25 2 1000

0 0 0
0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F)
Flow - USgpm (105 SUS oil @ 120°F)

A-108 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV11-8-4

SV11 – 8 (V) – 4 (M) – (S) ** – **** * P – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV11 - Solenoid valve Blank - Cartridge only Blank - No coil


S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
8 - 8 size
CODE PORT SIZE HOUSING NUMBER N - Deutsch (DC only)
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-160751 (DC only)
V - Viton® 3G 3/8” BSPP 02-160752 J - Metripack 280 male
4T SAE 4 02-160753 (DC only)
4 Style
4 - 4-way, 2 position 6T SAE 6 02-160754 10 Coil series
See section J for housings. P - 8 series, 23 W
5 Manual override option
For coil dimensions see Section C.
Blank - No manual override 8 Voltage rating 24A - 24VAC
M - Manual override 115A - 115VAC
00 - No coil 11 Special features
For valve dimensions with manual 230A - 230VAC
12D - 12VDC 00 - None
override option installed see page A-153. 12B - 12VDC/w diode*
24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)

26,0
(1.02)
Dimensions
mm (inch)

Torque cartridge in
aluminum or steel housing Ø 31,7
34-41 Nm (25-30 ft. lbs) (1.25)
15,8 (0.62) hex
Note
When solenoid valve is
ordered as cartridge only, 58,4
nut is included. (2.30)

22,2 (0.87) hex

0.750"– 16 Thd.
4
54,5
WARNING (2.15)
3
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 2
mum torque on valve tube Ø 12,6 (0.500)
nut. Over tightening may Ø 14,2 (0.559) 1
cause valve failure. Ø 15,8 (0.622)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-109


SV11-10-4/4M
4-way 2-position spool type
solenoid valve, 350 bar

Description Operation
The SV11-10-4 is a 4-way, 2- In the de-energized posi- In the energized position,
position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 3 to port 2 and to port 4 and from port 2 to
tridge solenoid valve. from port 4 to port 1. port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 23 L/min (6 USgpm)
3 1
Internal leakage, port 2 to port 1 82 cm3/min. (5 in3/min.) max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/116/13
Housing material (standard) Steel
Weight cartridge only 0,21 kg (0.46 lbs)
Seal kit 889625 (Buna-N), 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont Co

Pressure Drop Curves


Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only
0 8 15 23
150

4 125 9

Pressure Drop - bar


Pressure Drop - psi

A
100 7
3
75 5
2 B
50 3
25
1 1
0
0 2 4 ?6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 3 to port 2
B - Port 4 to port 1

A-116 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code SV11-10-4

SV11 – 10 (V) – 4 (M) – (S) ** – **** * H – 00

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Valve housing material 9 Connector types

SV11 - Solenoid valve Blank - Omit for cartridge only Blank - No coil
S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
10 - 10 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-175139 (DC only)
V - Viton® J - Metripack 280 male
3G 3/8” BSPP 02-175140
(DC only)
4 Style 6T SAE 6 02-175137
4 - 4-way, 2-position 8T SAE 8 02-175138 10 Coil series

5 Manual override option


See section J for housings. H - 10 series, 29 W
For coil dimensions see Section C.
Blank - No manual override 8 24A - 24VAC
M - Manual override Voltage rating
115A - 115VAC 11 Special features
For valve dimensions with manual 00 - No coil
230A - 230VAC 00 - None
override option installed see page A-153. 12D - 12VDC
12B - 12VDC/w diode*
24D - 24VDC (Only required if valve
24B - 24VDC/w diode*
36D - 36VDC has special features,
*Optional arc suppression diode.
omitted if “00.”)
29,6
(1.16)
Dimensions
mm (inch)

Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs) Ø 38,9 22,2 (0.875) hex
(1.53)

Note
When solenoid valve is
ordered as cartridge only,
57,8
nut is included.
(2.28)

25,4 (1.00) hex

0.875" – 14 Thd.
4
61,8
(2.43) 3
WARNING
2
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- Ø 16,0 (.63)
mum torque on valve tube Ø 17,6 (.70) 1
nut. Over tightening may Ø 19,2 (.76)
cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-117


Electro-Proportional Valves
Section Introduction

This section gives basic tive, 2 way, pressure com- spool type, screw-in pres- and honed for long life
specifications for the com- pensated flow regulator. sure reducing/relieving valve. and low leakage
plete line of Vicker’s screw-in The ERV1-10 is an electric, It is capable of handling flows • Designed for maximum
proportional control valves. proportionally controlled, from 0-30 L/min (0-8 USgpm) flexibility and minimal
Its purpose is to provide a internally pilot operated, at set pressures from 35-207 space requirements
quick, convenient reference spool type screw-in relief bar (500-3000 psi).
tool when choosing propor- • All exposed cartridge sur-
valve. It is capable of han- Vickers proportional pressure faces are zinc dichromate
tional valves or when design- dling flows from 3,8-60,0 and flow control valves are
ing a system using these plated to resist corrosion
L/min (1-15 USgpm) at designed to be easily con-
components. pressures from 35-210 bar trolled by the simplest of DC • Reliable, economical and
The EPV10 has several out- (500-3000 psi). Also avail- electrical devices such as a compact
standing performance fea- able is an ERV1-16 which is 12 volt battery and a poten- • Rated flows up to 160
tures which give it a unique capable of handling flows tiometer. L/min (42 USgpm)
position in the screw-in car- from 7,6-132 L/min. (2-35 Varying the voltage at the • Optional nose-in, side-out
tridge valve market. Valve USgpm) at pressures from coil is one of the simplest or side-in, nose out flow
gain linearity, flow force 35-210 bar (100-500 psi). means of control available. direction (EPV16 series)
pressure compensation char- The ERV2-10 is a low flow Any of the Vickers DC coils
acteristics above 20 bar (300 electric proportionally con- will work on most of these
psi) and low internal leakage. Coil Features and Benefits
trolled relief valve similar to valves simply by varying the
The EPV16 is a proportionally the ERV1-10. This valve is voltage between 0 and 75% The valves in this catalog are
controlled two-way poppet rated for flows from 0,2-2,8 of the rated coil voltage. It offered with a choice of two
type valve. The main poppet L/min (0.05-0.75 USgpm) should be noted that as the or three standard voltages
amplifies a small flow and pressures up to 35 bar operating temperature of a and several types of electri-
through the pilot circuit and (500 psi). coil increases, the solenoid cal connections. For other
is comparable to a transistor. force decreases. Therefore if coil ratings and connections,
The ERV3-10 is a low flow consult your Eaton applica-
As the transistor uses small electric proportionally con- the voltage is held constant
currents to control larger cur- as the coil heats up then tions engineer.
trolled relief valve similar to
rents, the hydraulic valve the ERV2-10. This valve is valve pressure (or flow) will • Variety of voltages and
transistor or VALVISTOR rated for flows up to 0,8 change. terminations
uses the pilotflow to control L/min (0.20 USgpm) and The IRV1 is a proportionally • Coils are interchangeable
the main stage flow with pressures up to 207 bar controlled poppet type, relief for serviceability on the
servo-like response flow to (3000 psi). valve, with an inverse func- EPV10 and EPV16. Coils
control. tion. This valve is capable of are interchangeable for
The EPRV2-8 is an electric,
The ESV1 is a proportional proportionally controlled, handling flows up to 1 L/min serviceability on the
two-way, presssure compen- direct acting spool type, (0.25 USgpm) and press- ERV1-10, EPV1-16, EPRV1-
sated, poppet type flow con- screw-in pressure sures up to 210 bar (3000 10 and EPRV1-16
trol valve. The valve is avail- reducing/relieving valve. It is psi). • Compact, one-piece
able in 8, 10, and 12 sizes, capable of handling flows Electrical current controls weather-proof encapsu-
both normally open or nor- from 0-7,6 L/min (0-2 with PWM are recomended lated design. Eliminates
mally closed in the de-ener- USgpm) at set pressures for all Eaton proportional need for extra seals
gized position. from 0-22 bar (0-320 psi). valves. • An arc suppression diode
The EFV1 is a proportionally The EPRV1-10 is an electric, Closed-loop electrical control molded into the coil is
controlled two-way, spool proportionally controlled, with feedback from the available as a
type flow control valve. internally pilot operated, parameter to be monitored standard option
Technically the valve is not spool type, screw-in pres- will provide the most accu- on ERV, EPRV
pressure compensated, but sure reducing/relieving valve. rate control.
• and EFV valves
it is partiall flow force pres- It is capable of handling
sure compensated. flows from 0-7,6 L/min (0-2 Valve Features and Fluid Cleanliness
The EFV2 is a three port, USgpm) at set pressures Benefits Proper fluid condition is
pressure compensated, pro- from 14-35 bar (200-500 psi). • Products in this catalog essential for long and
portional flow control valve. Also available is an ERV1-16 have been fatigue tested satifactory life of hydraulic
The valve can be used as a which is capable of handling to one million cycles components and systems.
priority flow regulator, with flows from 0-38 L/min (0-10 at 132% or 10 million Hydraulic fluid must have
regulated flow being sup- USgpm) at set pressures cycles at 115% of rated the correct balance of
plied to port 3 and excess from 14-35 bar (200-500 psi). pressure cleanliness, materials, and
flow being by-passed to port The EPRV3-10 is an electric, additives for protection
2. If port 2 is blocked the • All operating parts are
proportionally controlled, hardened steel, ground against wear of compo-
valve functions as a restric- internally pilot operated, nents, elevated viscosity,
and inclusion of air.

B-4 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


WARNING
Application of
these products B
• beyond published
performance spec-
ifications may cause valve
malfunction which may
result in personal injury
and/or damage to
the machine.
WARNING
For pressures over 210 bar
(3000 psi) use steel
housing.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-5


ERV1-10
Proportionally controlled
pressure relief valve

1 1
Description 2 Operation
2
The ERV1-10 is an electric, This valve remains closed port 1, overcoming the
proportionally controlled, between port 1 and 2 until electrical force and open-
internally pilot operated, spool the predetermined pressure ing the spool to allow
type, screw-in relief valve. setting has been reached at flow from port 1 to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


1 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 2 - 240 bar (30 - 3500 psi)
1 Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
2 Rated flow 3,8 - 60,0 L/min (1 - 15 USgpm)
Cavity C-10-2
Standard housing materials Aluminum
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/116/13
Weight cartridge and coil 0,44 kg (0.98 lbs)
Seal kits 565803 (Buna-N)
565086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Override Characteristics

2 2

1 1

Pressure override, energized Pressure override, de-energized


Flow
Flow2 - L/min (21,8 cSt- L/min (21,8 cSt oil @ 49°C)
oil @ 49°C) Flow
Flow - L/min (21,8 cSt- L/min (21,8 cSt oil @ 49°C)
oil @ 49°C)
10 20 30 40 50 30 40 50
10 20 10 20 30 10 40 2050 30 40 50
3000 2 3000 200 100 100
200
1 6 6
Pressure Drop - bar
Pressure Drop - psi

Pressure Drop - psi


Pressure Drop - bar

Pressure Drop - bar


Pressure Drop - psi

Pressure Drop - psi

150 150
2000 1 2000
4
4
100 50 50
100

1000 1000cSt oil @ 49°C)


Flow - L/min (21,8 Flow - L/min (21,8 cSt oil @ 49°C) 2 2
50 50
10 20 30 40 50 10 20 30 40 50
Flow - L/min (21,8 cSt oil @ 49° C) 100 Flow
0 - L/min (21,8
0 cSt oil @ 49°
0 C) 0
3000 0 200 0 0
0 10 20 30 40 50 10 20 30 40 50
6
ssure Drop - psi

ssure Drop - psi


sure Drop - bar

sure Drop - bar

10 5 15 10 15 10 5 15 10 15
Pressure Drop - bar

Pressure Drop - bar

5
Pressure Drop - psi

Pressure Drop - psi

3000 100 5
200
150
Flow - USgpm
Flow - USgpm (105 SUS oil @ 120°F) (105 SUS oil @ 120°F) Flow - USgpm (105
Flow - USgpm (105 SUS oil @ 120°F)6 SUS oil @ 120°F)
2000
4
150
100 50
2000
4
1000
B-50 100 V-VLOV-MC001-E4 September, 2007 50
EATON Vickers Screw-In Cartridge Valves 2
50
1000 2
Model Code ERV1-10

ERV1 – 10 (V) – ** – ** – *** – * – 00

1 2 3 4 5 6 7 8

1 Function 4 Maximum pressure 5 Port size


ERV1 - Proportional relief (factory set) 0 - Cartridge only
valve Customer to specify settings
in increments of 7 bar (100 CODE PORT SIZE HOUSING NUMBER

2 psi) and coded in hundreds 6T SAE 6 566151*


Size
of psi within the 35-210 bar 2G 1/4” BSPP 876702
10 - 10 Size range (500-3000 psi) range.
3G 3/8” BSPP 876703
Example: 5 - 35,0 (500 psi) 6H SAE 6 876700
3 Seals
8H SAE 8 876701
Blank - Buna-N 6 Voltage rating *Light duty housing. See section J for housings.
V - Viton®
00 - No coil
12D - 12VDC 7 8
Connector Types Special Features
24D - 24VDC
WARNING 12B - 12VDC/w diode* Blank - No coil 00 - None
Maintain 5-8 Nm 24B - 24VDC/w diode* G - DIN 43650 (Only required when valve
• Q - Spade terminals
(4-6 ft. lbs) maxi- *Optional arc suppressing diode. has special features, omitted
mum torque on valve tube W - Leadwire if ”00.“)
Note: This valve uses the standard N - Deutch
nut. Over tightening may J series coils, see section C for
Y - Amp JR
cause valve failure. coil part numbers and specifications.

nse Volts
bar psi Step response Volts
9Dimensions Performance bar psi Step response Volts
Input voltage

mm (inch) 29,6 Characteristics


(1.16) 210 3000 9

voltage
6Torque Cartridges only 210 3000 9

voltage
cartridge Zero outlet 140 2000 6
3in aluminum pressure 140 2000 6 Input
housing Input 38,9
Ø 38,9 70 1000 3
47-54 Nm 70 1000 (1.53
38,
0.3 seconds
0.4 (35-40 (1.53) 3
ft. lbs) (1.53
time 19,0 (0.75) Hex 0
0 0 0.1 0.2 0.3 0.4 seconds
0 0.1 0.2 time
Response 0.3 0.4 seconds
Response time
gain
280 73,0
(2.87) Pressure gain
73
Pressure - bar

4000 Pressure gain 280


210 4000 280 (2.
7
- bar
- psi

25,4 (1.00) Hex (2


3000 210
- bar
- psi

140 3000 210


Pressure

Pressure
Pressure

Pressure

2000 140
70 33,3 2000 140
(1.31) 0.875"-14 Thd.
1000 70 33
2 1000 70 (1.
3
6 9 volts (1.
1
25C (77F) Ø 15,80 (0.622) 0 3 6 9 volts
Valve is shown with “W” coil.
Input voltage @ 25°C (77°F) 9 volts
0 3 6
Input voltage @ 25°C (77°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-51


ERV1-16
Proportionally controlled
pressure relief valve

Description Operation
The ERV1-16 is an electric, This valve remains closed port 1, overcoming the
proportionally controlled, between port 1 and 2 until electrical force and
internally pilot operated, spool the predetermined pressure unseating the spool to
1type, screw-in relief valve. setting has been reached at allow flow from port 2.
2
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 3,5 - 210 bar (50 - 3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
1 2
Rated flow 7,6 - 132,0 L/min (2 - 35 USgpm)
2 Cavity C-16-2
Standard housing materials Aluminum
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View 2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/116/13
Weight cartridge and coil 1 0,44 kg (0.98 lbs)
Seal kits 565810 (Buna-N)
889609 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Override Characteristics

Pressure override, Flow - L/min (21,8 cSt oil @ 49°C)


energized 40 80 120 160
3000 210
Pressure - psi

Pressure - psi
Pressure - bar
2 2000 140

1 1000 70

2
2 0 0
10 20 30 40 50
1 Flow - USgpm (105 SUS oil @ 120°F)

1
Flow - L/min (21,8 cSt oil @ Pressure
49°C) override, Flow - L/min (21,8 cSt oil @ 49°C)
40 80 120 de-energized
160 40 80 120 160
3000 210 100 7
Pressure - psi

Pressure - psi
Pressure - bar

Pressure - bar

2000 Flow - L/min (21,8 cSt oil @ 49°C) 140 Flow - L/min (21,8 cSt oil @ 49°C)
60 4
40 - L/min
Flow 80 (21,8
120 cSt160
oil @ 49°C) 40 - L/min
Flow 80 (21,8
120 cSt160
oil @ 49°C)
3000 210 100 7
1000 40 80 120 160
70 40 80 120 160
3000 210 30 100 2 7
Pressure - psi

Pressure - psi
Pressure - bar

Pressure - bar

2000 140
Pressure - psi

Pressure - psi
Pressure - bar

Pressure - bar

0 0 060 0 4
200010 20 30 40 50 140 10 20 30 40 50
60 4
1000Flow - USgpm (105 SUS oil @ 120°F) 70 30
Flow - USgpm (105 SUS oil @ 120°F)
2
1000 70 30 2
0 0 0 0
10 20 30 40 50 10 20 30 40 50
0 0 0 0
B-52 Flow - USgpm
EATON(105
20SUSScrew-In
10 Vickers oil
30 @ 120°F)
Cartridge Valves V-VLOV-MC001-E4 September, 2007 Flow - USgpm (105 SUS oil @ 120°F)
40 50 10 20 30 40 50
Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)
Model Code ERV1-16

ERV1 – 16 (V) – ** – *** – *** – * – 00

1 2 3 4 5 6 7 8

1 Function 4 Maximum pressure 5 Port size


ERV1 - Proportional relief (factory set) 0 - Cartridge only
valve Customer to specify settings
in increments of 7 bar (100 CODE PORT SIZE HOUSING NUMBER

2 psi) and coded in hundreds 12T SAE 12 566149*


Size
of psi within the 35-210 bar 4G 1/2” BSPP 876716
16 - 16 Size range (500-3000 psi) range.
6G 3/4” BSPP 876718
Example: 5 - 35,0 (500 psi) 10H SAE 10 876717
3 Seals
12H SAE 12 566113
Blank - Buna-N 6 Voltage rating *Light duty housing. See section J for housings.
V - Viton®
00 - No coil
12D - 12VDC 7 Connector Types 8 Special Features
24D - 24VDC
WARNING Blank - No coil 00 - None
12B - 12VDC/w diode*
G - DIN 43650 (Only required when valve
Maintain 5-8 Nm 24B - 24VDC/w diode*
• Q - Spade terminals has special features, omitted
(4-6 ft. lbs) maxi- *Optional arc suppressing diode. W - Leadwire
mum torque on valve tube if ”00.“)
Note: This valve uses the standard N - Deutch
nut. Over tightening may J series coils, see section C for Y - Amp JR
cause valve failure. coil part numbers and specifications.

onse Volts

bar
bar psi
psi Step response
Step response Volts
Volts
9Dimensions Performance
Input voltage

29,6
mm (inch) Characteristics
(1.16)
6Torque Cartridges only 210
210 3000
3000 99

voltage
Inputvoltage
cartridge
Pressure

Zero outlet
Pressure

140 2000
3in aluminum pressure 140 2000 66
housing Ø 38,9 Input
108-122 Nm 70 1000 3
0.3 seconds
0.4(80-90 (1.53) 70 1000 33 38
(1.
ft. lbs) (1.
time 19,0 (0.75)
Hex Torque 0
0 0
0 0.1
0.1 0.2
0.2 0.3
0.3 0.4
0.4 seconds
seconds
to 5-8 Nm
Response time
Response time
gain
280 79,0
(3.1)
Pressure gain
gain
Pressure - bar

210 Pressure
3600
3600 280
280
bar
psi

38,1 (1.50) Hex


Pressure- -bar
Pressure- -psi

140 3000 210


3000 210
Pressure

Pressure

70 44,4 2000 140


1.312"-12 Thd. 2000 140
(1.75)
2 1000 70
1000 70
6 9 volts
1
25C (77F) Ø 28,55 (1.124)
0 3 6 9 volts
0 3 6 9 volts
Valve is shown with “W” coil. Input voltage @ 25°C (77°F)
Input voltage @ 25°C (77°F)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-53


EPRV1-16
Proportional pressure
reducing-relieving valve

Description 1 (RP) 1 (RP)


Operation
• • reached at port 1, the spool If the pressure at port 1
The EPRV1-16 is an electric, This valve remains open
proportionally controlled, from port 2 to port 1 (port 3 shifts to restrict the inlet exceeds the setting of the
internally pilot operated, spool must be vented). Once the flow at port 2, which regu- valve, the spool will shift far-
type, screw-in relief valve. predetermined pressure is lates the pressure at port 1. ther and relieve to port 3.
2 (P) 2• (P) •
3 (T) 3 (T)
Functional Symbol RATINGS AND SPECIFICATIONS
1 (RP) Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
•1 (RP)
Typical application pressure (all ports) 3,5 - 35 bar (0 - 500 psi)
Cartridge fatigue pressure (infinite life) 35 bar (500 psi)
Rated flow 0 - 38,0 L/min (0 - 10 USgpm)
2 (P) • Cavity C-16-3
2 (P) 3 (T) Standard housing materials Aluminum
3 (T)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/116/13
Weight cartridge and coil 0,9 kg (2.00 lbs)
Seal kits 565811 (Buna-N)
889599 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Override Characteristics

3 3

2 2

1 1
3

3
2 Pressure override, energized Pressure override, de-energized
2 Flow - L/min
Flow -(28,0
L/mincSt
(28,0 cSt
oil @ oil @ 49°C)
49°C) Flow (28,0
Flow - L/min - L/min (28,0
cSt oil @cSt oil @ 49°C)
49°C)
1 38 3819 190 019 19
38 38 38 3819 19 0 0 19 19
38 38
600 42 50 50
1600 42
3 3

28 28
Pressure - psi

Pressure - psi

400
Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi

400
Pressure - bar

Pressure - bar

Flow - L/min (28,0 cSt oil @ 49°C) - L/min 25


Flow 25 (28,0 cSt oil @ 49°C) 2 2
200 2000 14 1438 19 Flow - L/min
0
38 19 (28,0
Flow - L/min cSt oil @1949°C)38
50 (28,0 19
cSt oil @38
49°C)
600 42
7 4 0 4 7 7 4 0 4 37
600 0 0 42 0 0 45 3
0 0 0 0
10 105 50 2805 5
10 10 10 5 5 0 0 5 510 10
- psi - psi

Pressure - psi

400 10
- bar- bar

Pressure - bar

Flow - USgpm
Flow - USgpm (135 SUS oil @ 120°F)
(135 SUS Flow - USgpm (135
oil SUS oil @ 120°F)
28 oil @ 120°F) 25 Flow - USgpm (135 SUS @ 120°F)
Pressure - bar
Pressure - psi
Pressure

400 2
Pressure

200 14
Pressure

Pressure

15 1

200
B-60 14 V-VLOV-MC001-E4 September, 2007
EATON Vickers Screw-In Cartridge Valves
0 0
0 0
Model Code EPRV1-16

EPRV1 – 16 (V) – ** – *** – *** – * – 00

1 2 3 4 5 6 7 8

1Function 4 Maximum pressure 5 Port size


EPRV1 - Proportional (factory set) 0 - Cartridge only
reducing/relieving valve Customer to specify settings
in increments of 7 bar (100 CODE PORT SIZE HOUSING NUMBER

2 psi) and coded in hundreds 6B 3/4” BSPP 02-175465*


Size
of psi within the 14-35 bar 12T SAE 12 566162*
16 - 16 Size range (200-500 psi) range. 6G 3/4” BSPP 876722
Example: 5 - 35,0 (500 psi) 10H SAE 10 876721
3Seals
12H SAE 12 876723
Blank - Buna-N 6 Voltage rating *Light duty housing. See section J for housings.
V - Viton®
00 - No coil
12D - 12VDC 7 Connector Types 8 Special Features
24D - 24VDC
WARNING 36D - 36VDC Blank - No coil 00 - None
Maintain 5-8 Nm 12B - 12VDC/w diode* G - DIN 43650 (Only required when valve

(4-6 ft. lbs) maxi- 24B - 24VDC/w diode* Q - Spade terminals has special features, omitted
W - Leadwire if ”00.“)
mum torque on valve tube *Optional arc suppressing diode. N - Deutch
nut. Over tightening may Note: This valve uses the standard Y - Amp JR
cause valve failure. J series coils, seesection C for
coil part numbers and specifications.
nse volts
9
Dimensions Performance bar
bar psi
psi Stepresponse
Step response volts
volts
Input voltage

6 mm (inch) Characteristics 42 600


42 600 99
pressure
Reducedpressure

Torque Cartridges only 1

voltage
Inputvoltage
3 cartridge Zero outlet (0(
28
28 400
400 66
in aluminum pressure
housing 3
Reduced

14 200
Input 38
14 200 33 (1
0,3 0,4 108-122 Nm
seconds (1.
(80-90 ft. lbs)
time
00
00 0,1 0,2
0,1 0,2 0,3
0,3 0,4 seconds
0,4 seconds
gain Response time
Response time
34
Pressure - bar

Pressuregain
Pressure gain
500 34
34
500
bar
psi

Pressure--bar
Pressure--psi

17
Pressure
Pressure

250 17
17
250
6 9 volts 1
25C (77F)
00 33 66 volts
99 volts
Valve is shown with “W” coil. Inputvoltage
voltage@@25°C
25°C(77°F)
(77°F)
Input

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-61


EPV16
Valvistor®
Proportional flow
control valve

Functional Symbols Description Operation


3 1 The EPV16 is a 2-way, “A” style (nose in, side out) “B” style (side in, nose out)
2
3 1
2 3 1 normally closed, pressure - In the de-energized posi- - in the de-energized posi-
2
compensated, poppet tion this valve remains tion the valve remains
2 type, screw-in cartridge closed from port 1 to port closed from port 2 to port
1
2 electro-proportional flow 2. When current is applied 1. When current is applied
EPV16-A1 1 EPV16-B 2
EPV16-A EPV16-B
control valve. to the coil, a controlled to the coil, a controlled
EPV16-A
EPV16-A EPV16-B
EPV16-B increasing flow will be increasing flow will be
allowed from port 1 to port allowed from port 2 to port
Sectional View 2, in proportion to the cur- 1. In both examples free
rent applied. reverse flow is allowed in
EPV16-A Side-out, nose-in
the opposite direction.

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure 280 bar (4000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) NFPA rated
Rated flow 0 to 160 L/min (42 USgpm)
Operating media temperature -30° to 90°C (-22° to 194°F)
Cavity C-16-3S (undercut)
Fluids Antiwear hydraulic oils with Buna-N seals (standard)
Phosphate esters (non-alkyl) with Viton® seals are available by request
Viton is a registered trademark of E.I. DuPont

2
Weight cartridge only 1 kg (2.2 lbs)
Filtration 70 - 210 bar (1000 - 3000 psi) Cleanliness code 17/115/12
1 2 210+ bar (3000+ psi) Cleanliness code 15/113/11
2
1 Standard housing materials Aluminum or steel
1 Typical hysteresis Less than 4% of rated current @ 10 bar
pressure drop – Pulse Width Modulated (PWM)
EPV16-B Side-in, nose-out
Internal leakage @ 140 bar (2000 psi) EPV16A 50 cm3/min maximum
and oil viscosity 30cSt EPV16B 10 cm3/min maximum
Oil viscosity range 10 - 800 cSt
Nominal supply voltage 12 or 24 VDC
Threshold current Adj from 350 - 600 mA (12 VDC)
Adj from 175 - 250 mA (24 VDC)
Coil current for maximum flow 0.7 amps @ 24 VDC
1.4 amps @ 12 VDC
Recommended PWM frequency 100 -200 Hz application dependent, 150 Hz typ
Coil resistance @ 20°C (68°F) 12V-6.5Ω/24V-25.0Ω
2
Power consumption @ rated current 12V-12.8 watts
1 and 20°C coil temperature 24V-12.8 watts
Cartridge seal kit 02-154069 (Buna-N)
2
2
1
1

B-10 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code EPV16

EPV 16 – * – ** – * – *** – ** – *** – * – * – **

1 2 3 4 5 6 7 8 9 10 11

1 Function 6 Port Size

EPV - Electro-proportional 0 - Cartridge only


flow control valve, poppet
type CODE PORT SIZE HOUSING NUMBER
Aluminum Steel
EPV16-A EPV16-B EPV16-A EPV16-B
2 Size 4G 1/2” BSPP 02-185448 02-166607 02-180050 02-165500
16 - 16 Size 6G 3/4” BSPP 02-185449 02-161582 02-180051 02-164931
10H SAE 10 02-185446 02-170238 – –
3 Flow direction 12H SAE 12 02-185447 02-166609 – –
A - Nose-in, side-out 10T SAE 10 – – 02-180048 02-161983
B - Side-in, nose-out 12T SAE 12 – – 02-180049 02-161982
5C CETOP5 (NFPA D05) Interface (Requires steel body)
4 Rated flow @ 10 bar ∆P See section J for housings.
04 - 40 L/min (10.5 USgpm) used when system pressure does not exceed 210 bar (3000 psi). The screw type can be
7 Seals & Filter used at any system pressure.
06 - 60 L/min (16 USgpm)
10 - 100 L/min (26 USgpm) N - Buna-N
16 - 160 L/min (42 USgpm) V - Viton 10 Coil/Connector types
NF - Buna-N and 60 mesh
CONNECTOR COIL PART NUMBER
filter screen
5 Valve housing material VF - Viton and 60 mesh filter 12VDC 24VDC
Omit for cartridge only screen Blank - No coil
A - Aluminum W - Leadwire (DC only) 02-154072 02-154073
S - Steel Q - Spade terminals (DC only) 02-317154 02-317155
8 Voltage rating
U - DIN 43650 02-154070 02-154071
Aluminum hous-
12D - 12VDC Y - Metri-Pack 150 male* 02-308808 02-308809
ings can be used
• for pressures up 24D - 24VDC F - Weather-Pack male 02-308810 02-308811
to 210 bar (3000 N - Deutsch DT04-2P 02-390736 02-391885
psi). Steel housings must be 9 *Preferred Packard connector.
Manual override option See Section C for coil information.
used for operating pressures
above 210 bar (3000 psi). Blank - No manual override
M - Pin type 11 Design number
S - Screw type
*Manual override is available in two differ-
ent configurations, either push pin type is WARNING
When using the “Screw Type” override, care

M - Pin type manual S - Screw type manual must be taken to return the override back to its
override option override option neutral position before activating the valve. Failure to take
this precaution may result in personal injury or damage to
the machine.
CAUTION
A separate check valve is required down stream

to isolate the EPV valve from load forces when
the EPV is used to hold a load.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-11


Dimensions
EPV16-A
2

2 2

1 1

EPV16-A 2 Note
Nose-in, side-out When stand alone housings
mm (inch) are used, the following
guidelines apply:
• EPV16-A: Port 3 is to be
1 plugged.
Screw type • EPV16-B: Port 3 is to
actuator (shown) 3 be connected to port 1
mm hex socket in order to provide the
Screw type Screw type
actuator (shown) 3 actuator (shown) 3 required feedback
mm hex socket mm hex socket flow path. Ø 43,5 (1.71)
27,3 (1.07)
Ø 43,5 (1.71) Ø 43,5 (1.71)
27,3 (1.07) 27,3 (1.07)

Screw type 129,0 124,7


actuator (shown) 3 (5.07) (4.90)
mm hex socket
129,0 129,0 124,7 124,7
(5.07) (5.07) (4.90) (4.90)
Ø 43,5 (1.71)
27,3 (1.07) 185,3 67,9 1
(7.29) (2.67) (
185,3 185,3 67,9 181,0 67,9 1
(7.29) (7.29) (2.67) (7.12) (2.67) (

129,0 124,7
(5.07) (4.90) 1.312"
-12 Thd.
1.312" 1.312"
2 -12 Thd. 2 -12 Thd.
185,3 67,9 181,0
(7.29) (2.67) (7.12)
2 1 2 2 1 2
38,1 Hex (1.50) Ø 25,4 (1.00)
1 1
With manual actuator 1 1
No manual actuator
38,1 Hex (1.50) 38,1 Hex (1.50) Ø 25,4 (1.00) Ø 25,4 (1.00)
1.312"
With manual actuator With manual actuator No manual actuator
-12 Thd. No manual actuator

Valves are shown with “U” coil. See Section C for coil information.
2 Torque cartridge in aluminum housing 108-122 Nm (80-90 ft. lbs) 2
Torque cartridge in steel housing 136-149 Nm (100-110 ft. lbs)
1 1
38,1 Hex (1.50) Ø 25,4 (1.00)
With manual actuator No manual actuator

B-12 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Dimensions
EPV16-B

1 1
3

3 3
2 B
2 2
EPV16-B Required external
1
Side-in, nose-out connection with standard
mm (inch)
C-16-3S cavity
3

Screw type 2
actuator (shown) 3
ScrewScrew mm
type hex socket
type
actuator
actuator (shown)
(shown) 3 3
mmmm hex hex socket
socket Ø 43,5 (1.71)
27,3 (1.07)

27,327 ,3 (1.07)
(1.07) Ø 43,5
Ø 43,5 (1.71)
(1.71)

129,0
Screw type (5.07)
actuator (shown) 3 124,7
mm hex socket 129,0
129,0 (4.90)
(5.07)
(5.07) 124,7124,7
(4.90)
(4.90)
27,3 (1.07) 185,3Ø 43,5 (1.71) 67,9
(7.29) (2.67) 181,0
(7.12)
185,3
185,3 67,967,9
(7.29)
(7.29) (2.67)
(2.67) 181,0
181,0
(7.12)
(7.12)
129,0
(5.07) 124,7
3 1.312"-12 Thd.
(4.90) 3

3 3 1.312"-12
1.312"-12 Thd.Thd.
2 3 3 2
185,3 67,9
(7.29) (2.67) 181,0
2 12 (7.12) 2 12
38,1 Hex (1.50) Ø 25,4 (1.00)
1 1 1 1 Ø 28,6 (1.12)
38,138,1
HexHex (1.50)
(1.50) Ø 25,4
Ø 25,4 (1.00)
(1.00)
With manual actuator No Ø
manual actuator
Ø 28,6
28,6 (1.12)
(1.12)
3 1.312"-12 Thd.
3
WithWith manual
manual actuator
actuator No manual
No manual actuator
actuator
2 2

1 1
For EPV16-B (flow 2 to 1), Port 3 must be connected to Port 1 externally to the cartridge,
38,1 Hex (1.50)either by passages in the cavity block or external plumbing.ØWhen
25,4purchased
(1.00) with undercut
body, this connection is included in the body and Port 3 is not machined.
Ø 28,6 (1.12)
A separate external port connection is not required for EPV16-A (flow 1 to 2).
With manual actuator No manual actuator

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-13


Dimensions
EPV16

EPV16-A-**-S-5C-**-D-(*)-*-12
CETOP 5 Interface
mm (inch)
.250-20 UNC x 2.500"
socket head cap screw
(BoltUNC
.250-20 x 2.500"
Kit 255634) 71,6 (2.82)
276,0 (10.9) Required for removal
M6socket head cap
x 60 socket headscrew
cap 71,6 (2.82)
219,7 (8.65)
276,0 (10.9) Required for removal (BoltKit
screw (Bolt Kit689623)
255634)
M6 x 60 socket head cap 69,5 (2.74)
219,7 (8.65)99,5 (3.92) screw (Bolt Kit 689623) 69,5 (2.74)
99,5 (3.92)
60,0
(2.38) 51,0
60,0
(2.38) (2.01)
51,0
(2.01)
ISO-4401-AC-05-4-A (NFPA D05)
mounting surface
ISO-4401-AC-05-4-A (NFPA D05)
mounting surface 22,8 (0.89)
P
22,8 (0.89)
P 11,7 (0.46)
B ? A
11,7 (0.46)
Tb B ? A Ta
Tb Ta P A B Ta Tb
P A B Ta Tb
?
Ø 6,96/6,85 thru 4 holes
?
Ø 6,96/6,85 thru 4 holes
EPV16-B-**-S-5C-**-D-(*)-*-12
CETOP 5 Interface
mm (inch)
PA B Tb Ta
P removal
276,0 (10.9) Required for A B Tb Ta
219,7Required
276,0 (10.9) (8.65) for removal
71,6 (2.82) .250-20 UNC x 2.5"
69,5 (2.74) socket head cap screw 99,5 (3.92) 219,7 (8.65)
71,6 (2.82) .250-20
(Bolt UNC x 2.5"
Kit 255634)
socket 99,5 (3.92)
69,5 (2.74) M6 x 60head caphead
socket screw
cap
(Bolt Kit
screw 255634)
(Bolt Kit 689623)
60,0 M6 x 60 socket head cap
51,0 (2.38) screw (Bolt Kit 689623)
60,0
(2.01) (2.38)
51,0
(2.01)

ISO-4401-AC-05-4-A
(NFPA D05) 22,8 (0.89) 11,7 (0.46)
ISO-4401-AC-05-4-A
mounting surface
(NFPA D05) 22,8 (0.89)
P 11,7 (0.46)
mounting surface
P
B ? A
Note Tb B ? A Ta
CETOP 5 Seal Kit 02- Tb Ta
319667
Ø 6,96/6,85 thru 4 holes
Ø 6,96/6,85 thru 4 holes

B-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Performance
Curves
EPV16

Pressure Differential
Pressure Differential -- psi
psi
Pressure Differential - psi B

–2000

–3000
–2500

–3500
–1500

–4000
–2000

–3000
–2500

–3500
–1500

–4000
–500
–500
–2000

–3000
–2500

–3500
–1500

–4000
–0
–500

–0
II H G
–0

150
150 H G
Typical pressure
150 I H G 140
140 COMMAND CURRENT
140
compensation 120 FF 12V 24V
120 F
120 A– 600 mA 300mA
100
100 EE B– 700 mA 350mA
%*

100
Flow%*

80 E
Flow %*

80 C– 800 mA 400mA
80
Flow

60
60 D D– 900 mA 450mA
60 D
40 D E– 1000 mA 500mA
40 C
C
40 C B F– 1100 mA 550mA
20
20 B
20 B A
A G– 1200 mA 600mA
0 A H– 1300 mA 650mA
0
0

260
280
200
220
240
140
I– 1400 mA 700mA
20
40
60
80
100 00

100

160
180
120

260
280
200
220
240
140
12020

40
60
80
100

160
180
120

260
280
200
220
240
140
20
40
60
80
0

160
180

Pressure Differential
Pressure Differential -- bar
bar
Pressure Differential - bar
** Flow
Flow interims
interims of
of %
% for each poppet
for each poppet size
size
* Flow interims of % for each poppet size
E
E
E DC
D
DC C
Typical metering 150
150 B PRESSURE DIFFERENTIAL
150 140
140 B B
performance140 A– 10 bar 150 psi
120
120 UPPER
UPPER TOLERANCE OF FLOW
TOLERANCE OF FLOW B– 20 bar 300 psi
120 UPPER TOLERANCE OF FLOW A
100
100 A A C– 50 bar 700 psi
100 NOMINAL FLOW (LOWER
(LOWER TOLERANCE)
TOLERANCE)
%*

NOMINAL FLOW D– 100 bar 1500 psi


Flow%*

80
NOMINAL FLOW (LOWER TOLERANCE)
Flow %*

80 80
E– 200 bar 3000 psi
Flow

60
60
60

40 40
40
20 20
20
0 0
0
(24V) 100 300 100
200 (24V)
(24V) 100 200
400 200 300600 400
500 300 400 500 600
700 500 600 700
700
(12V) 200 400 (12V)
600 200
(12V) 200 400
800 400 600
1000 600 800
1200 800 1000 1200
1400 1000 1200 1400
1400
Command Current, mA
Command Current,
Command Current, mA mA
** Flow
Flow
* Flow interims of % for each interims
sizeof
interims
poppet of %
% for each poppet
for each poppet size
size

Step response PRESSURE DROP @ 120 L/MIN (30 USGPM)


definition of terms On Stroke Off Stroke
Pressure Delay/ Delay/
COMMAND SIGNALCOMMAND SIGNAL
COMMAND SIGNAL 100%
drop ∆P Reach 90% Reach 90%
100% 100%
20 bar (290 psi) 24 ms/35ms 5 ms/15 ms
0 100 bar0(1450 psi) 24 ms/17ms 5 ms/7ms
0
Delay Delay
Delay Delay Delay
Delay
FLOW RESPONSE
FLOW RESPONSE FLOW RESPONSE
90% 90%
90% 100% 100%
100%
90% Reach time 90%
90% Reach
Reach time
time 90% Reach time 90% Reach
90% Reach time
time
10% 10%
10%
0 00
On stroke On
On stroke
stroke Off stroke valve Off stroke
Off stroke valve
valve
valve valve
valve TIME TIME
TIME response time response time
response time
response response
response
time time
time

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-15


ESV1-8-O
Proportional flow control valve

Description Operation
The ESV1-8-O is a 2-way, 2- In the de-energized posi- In the energized position, The valve flow is propor-
position, pilot operated, tion, this valve allows free flow is blocked from port 2 tional to the current applied
poppet type, normally flow from port 2 to port 1 to port 1, and free flow is to the coil.
open, proportional flow, and restricts flow from port allowed from port 1 to port
control, screw-in cartridge 1 to port 2. 2.
valve.

RATINGS AND SPECIFICATIONS


Functional Symbol Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure 210 bar (3000 psi)
2 Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated flow @ 500 psid, 8.4 gpm min, 9.3 gpm nom
Hysteresis 1 Usgpm with dither
1
Leakage (fully closed) 5 drops/min max @ 3000 psi
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24V
Current to fully close valve 1100-1250 mA (12V coil), 550-625 mA (24V coil)
Profile View
Weight cartridge only Cartridge only .10 Kg (.23 lbs)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Cavity C-8-2
Seal Kit 02-165875 (Buna-N), 02-165877 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop At Max Poppet Opening


Pressure Drop - bar Flow vs. Current at 500 PSID

30 12

10
25
Flow - USgpm

Flow - L/min

8
Flow - L/min
Flow - USgpm

20

15 6

10
4
2
5
2
0 500 1000 1500 2000 2500 3000
Pressure Drop - PSID 0
1 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
Current - Amps

B-16 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code ESV1-8-O

ESV1 8 – * – O – * – ** – *** – * – * – * – ** – *

1 2 3 4 5 6 7 8 9 10 11 12

1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER 10 Coil Series
trol
Aluminum Blank - No Coil
2 Size 0 Cartridge Only S - S Series, 20 W
8 - 8 Size 2G 1/8" BSPP 02-160727 11 Coil Special Features
3G 3/8” BSPP 02-160728 Blank - No coil
3 Seal Material 4T SAE 4 02-160730 00 - No Special Feature
Blank - Buna N
V - Viton 6T SAE 6 02-160731
12 Valve Special Features
8T SAE 8 02-160732
4 Style See section J for housing details. Blank - None
O - Normally open
7 Coil Voltage 9 Connection Type
00 - No coil Blank - No Coil
5 Housing Material 012 - 12 VDC G - ISO 4400 DIN 43650
Blank - Cartridge only 024 - 24 VDC N - Deutsch (DC Only)
A - Aluminum P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.

19,0 HEX
(0.75) 26,2
(1.03)

64,3
(2.53)

Ø 31,8
(1.25)

22,2 HEX
(0.87)

27,8
(1.09) 2 0,750” - 16 THD

Ø 12,62
(.497)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-17


ESV1-8-C
Proportional flow control valve

Description Operation
The ESV1-8-C is a 2-way, 2- In the de-energized posi- In the energized position, The valve flow is propor-
position, pilot operated, tion, this valve blocks flow flow from port 1to port 2 is tional to the current applied
poppet type, normally from port 2 to port 1and restricted while free flow is to the coil.
closed, proportional flow free flow is allowed from allowed from port 2 to port
control, screw-in cartridge port 1 to port 2. 1.
valve.

RATINGS AND SPECIFICATIONS


Functional Symbol Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated flow @ 500 psid, 8.4 gpm min, 9.3 gpm nom
Hysteresis 1 Usgpm with dither
Leakage (fully closed) 5 drops/min max @ 3000 psi
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24V
Current to open valve 1350-1450 mA (12V coil), 075-725 mA (24V coil)
Profile View
Weight cartridge only Cartridge only .11 Kg (.24 lbs)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Cavity C-8-2
Seal Kit 02-165875 (Buna-N), 02-165877 (Viton)
Viton is a registered trademark of E.I. DuPont

Pressure Drop At Max Poppet Opening Flow vs. Current at 500 PSID
Pressure Drop - bar 12
30
10
25
Flow - USgpm

Flow - L/min

8
Flow - L/min
Flow - USgpm

2 20
6
15
4
1 10

5 2

0 500 1000 1500 2000 2500 3000 0


0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
Pressure Drop - PSID
Current - Amps

B-18 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code ESV1-8-C

ESV1 8 – * – C – * – ** – ** – * – * – * – ** – **

1 2 3 4 5 6 7 8 9 10 11 12

1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER 10 Coil Series
trol
Aluminum Blank - No Coil
2 Size 0 Cartridge Only S - S Series, 20 W
8 - 8 Size 2G 1/4" BSPP 02-160727
11 Coil Special Features
3G 3/8” BSPP 02-160728
3 Seal Material Blank - No coil
4T SAE 4 02-160730 00 - No Special Feature
Blank - Buna N
V - Viton 6T SAE 6 02-160731
8T SAE 8 02-160732 12 Valve Special Features
4 Style See section J for housing details. Blank - None
C - Normally closed
7 Coil Voltage 9Connection Type
5
00 - No coil Blank - No Coil
Housing Material 012 - 12 VDC G - ISO 4400 DIN 43650
Blank - Cartridge only 024 - 24 VDC N - Deutsch (DC Only)
A - Aluminum
P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.

19,1 HEX
(.75)
26,2
(1.03)

52,5
(2.07)

Ø 31,8
(1.25)
22,1 HEX
(.875)

27,8
(1.09) 0,750” - 16 THD.
2

Ø 12,62
(.497)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-19


ESV1-10-O
Proportional flow control valve

Description Operation
The ESV1-10-O is a 2-way, In the de-energized posi- In the energized position, The valve flow is propor-
2-position, pilot operated, tion, this valve allows free flow is blocked from port 2 tional to the current applied
poppet type, normally flow from port 2 to port 1 to port 1, and free flow is to the coil.
open, proportional flow, and restricts flow from port allowed from port 1 to port
control, screw-in cartridge 1 to port 2. 2.
valve.

RATINGS AND SPECIFICATIONS


Functional Symbol Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated flow @ 500 psid, 18.5 gpm min, 19.4 gpm nom
Hysteresis 1 Usgpm with dither
Leakage (fully closed) 5 drops/min max @ 3000 psi
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24V
Current to fully close valve 1000-1200 mA (12V coil), 500-600 mA (24V coil)
Profile View
Weight cartridge only Cartridge only .14 Kg (.30 lbs)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Cavity C-10-2
Seal Kit 0565803 (Buna-N), 0566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop At Max Poppet Opening


Pressure Drop - bar
50 Flow vs. Current at 500 PSID

45 24

40 20
2
35
Flow - USgpm

Flow - L/min

16
Flow - L/min
Flow - USgpm

30
1
25 12
20
8
15
10 4

5 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
0 500 1000 1500 2000 2500 3000 Current - Amps
Pressure Drop - PSID

B-20 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code ESV1-10-O

ESV1 10 – * – O – * – ** – *** – * – * – * – ** – **

1 2 3 4 5 6 7 8 9 10 11 12

1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER
trol 10 Coil Series
Aluminum Blank - No Coil
2 Size 0 Cartridge Only J - J Series, 20 W
10 - 10 Size 3B 3/8" BSPP 02-175462
11 Coil Special Features
6T SAE 6 566151
3 Seal Material 2G 1/4" BSPP 876702 Blank - No coil
Blank - Buna N 00 - No Special Feature
V - Viton 3G 3/8" BSPP 876703
6H SAE 6 876700 12 Valve Special Features
8H SAE 8 876701 Blank - None
4 Style
See section J for housing details.
C - Normally Open
7 Coil Voltage 9 Connection Type
5 Housing Material 00 - No coil Blank - No Coil
Blank - Cartridge only 012 - 12 VDC G - ISO 4400 DIN 43650
A - Aluminum 024 - 24 VDC N - Deutsch (DC Only)
P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.

19,1 HEX
(.75) 34,6
(1.36)

70,3
(2.77)

Ø 38,9
(1.53)

25,4 HEX
(1.00)
31,7
(1.25) 0,875” - 14 THD.
2

Ø 15,80
(.622)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-21


ESV1-12-O
Proportional flow control valve

Description Operation
The ESV1-12-O is a 2-way, In the de-energized posi- In the energized position, The valve flow is propor-
2-position, pilot operated, tion, this valve allows free flow is blocked from port 2 tional to the current applied
poppet type, normally flow from port 2 to port 1 to port 1, and free flow is to the coil.
open, proportional flow, and restricts flow from port allowed from port 1 to port
control, screw-in cartridge 1 to port 2. 2.
valve.

RATINGS AND SPECIFICATIONS


Functional Symbol Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated flow @ 500 psid, 27.3 gpm min, 28.9 gpm nom
Hysteresis 1 Usgpm with dither
Leakage (fully closed) 5 drops/min max @ 3000 psi
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24V
Current to fully close valve 800-900 mA (12V coil), 400-450 mA (24V coil)
Profile View
Weight cartridge only Cartridge only .24 Kg (.52 lbs)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Cavity C-12-2
Seal Kit 02-165889 (Buna-N), 02-165888 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop At Max Poppet Opening


Pressure Drop - bar
75 Flow vs. Current at 500 PSID
70 35

65 30
60
55 25
2
Flow - USgpm

Flow - L/min

50
Flow - L/min
Flow - USgpm

45 20
40
1 35 15
30
25 10
20
15 5
10
5 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
0 500 1000 1500 2000 2500 3000 Current - Amps
Pressure Drop - PSID

B-24 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code ESV1-12-O

ESV1 12 – * – O – * – ** – ** – * – * – * – ** – **

1 2 3 4 5 6 7 8 9 10 11 12

1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER
trol 10 Coil Series
Aluminum Blank - No Coil
2 Size 0 Cartridge Only J - J Series, 20 W
12 - 12 Size 4G 1/2" BSPP 02-161118
11 Coil Special Features
4GU 1/2" BSPP 02-161116
3 Seal Material Blank - No coil
6G 3/4" BSPP 02-161117
Blank - Buna N 00 - No Special Feature
V - Viton 6GU 3/4" BSPP 02-161115
10T SAE 10 02-160640 12 Valve Special Features
10TU SAE 10 02-160641 Blank - None
4 Style
12T SAE 12 02-160644
0 - Normally Open
12TU SAE 12 02-160645
See section J for housing details.
5 Housing Material 7 Coil Voltage 9 Connection Type
Blank - Cartridge only
A - Aluminum 00 - No coil Blank - No Coil
012 - 12 VDC G - ISO 4400 DIN 43650
024 - 24 VDC N - Deutsch (DC Only)
P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - 1DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.

19,1 HEX
(.75)
34,6
(1.36)

72,2
(2.87)

Ø 38,9
(1.53)

31,8 HEX
(1.25)

1.062” - 12 THD.
44,7 2
(1.76)

Ø 23,75
(.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-25


EFV1-10-O
Proportional flow control
valve, normally open,
spool type

Description Operation
The EFV1-10-O is a normally The valve is controlled by The maximum intended different from those
open, unidirectional, current supplied to the coil. pressure drop is 300 PSID. obtained with flow from
uncompensated, spool At zero current, the valve is At pressure drops above port 2 to port 3.
type, two way, proportional fully open from port 2 to 300 PSID, almost no Since the spool and arma-
flow control, screw-in car- port 3. At 1500 to 1600 mA increase in flow is obtained. ture are pressure balanced,
tridge valve. (12V coil) the valve is fully The intended flow direction
closed. Port 1 is used for is from port 2 to port 3. the operating pressure
pressure balancing the Operation of the valve with does not affect the operat-
spool and armature and flow from port 3 to port 2 ing characteristics of the
must be blocked in all will produce flow vs current valve. The operating point
cases. and flow vs pressure drop of the valve is determined
curves that are significantly only by current, pressure
drop and temperature.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with DTE 24 hydraulic fluid at 120°F
2 Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
1 Rated maximum flow at 160 PSID Flow rating “A” 15.1 L/min (4 USgpm)
3 Flow rating “B” 30.2 L/min (8 USgpm)
Flow rating “C” 37.9 L/min (10 USgpm)
Hysteresis 1 USgpm with 400Hz PWM driver
Leakage (fully closed) 197 cm3/min (12 in3/min) at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Profile View
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)
Recommended PWM frequency 200 - 400 Hz
Coil resistance at 20°C (68°F) 4.7 ω (12V), 19.0 ω (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/16/13
Cavity C-10-3
3 Seal kit 9900225-000 (Buna-N)
9900226-000 (Viton®)
3
2 Viton is a registered trademark of E.I. DuPont

1 2
1
Note
Port 1 is unused and must
be plugged.

B-28 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Performance
Curves
EFV1-10-O
Cartridge Only

Max. Flow vs Pressure Drop Max. Flow vs Pressure Drop


Flow rating "A" (Valve fully open) Flow rating "B" (Valve fully open)

Pressure Drop - bar Pressure Drop - bar

16 0 3.4 6.9 10.3 13.8 17.2 20.7


60 16 0 3.4 6.9 10.3 13.8 17.2 20.7
60
14 14
50 50
12 12

Fl o w - U S g p m
Fl o w - U S g p m

Fl o w - L/m i n
40 Fl o w - L/m i n 40
10 10
8 30 8 30
6 6
20 20
4 4
2 10 2 10
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pressure Drop - PSID Pressure Drop - PSID

Max. Flow vs Pressure Drop Flow vs. Current


Flow rating "C" (Valve fully open)

Pressure Drop - bar

16 0 3.4 6.9 10.3 13.8 17.2 20.7


60 100
14
50
12 75
Fl o w - U S g p m

Fl o w - L/m i n

40
Fl o w %

10
50
8 30
6
20 25
4
2 10
0
0 0 0 200 400 600 800 1000 1200 1400 1600
0 50 100 150 200 250 300
Current - mA
Pressure Drop - PSID
Note
To determine operating
characteristics for the flow
rating selected, at a specific
differential pressure, first
determine maximum flow
from upper curve at the dif-
ferential pressure value.
This will be the “100%
flow” flow on the lower
curve.
Parameters: 400 Hz PWM

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-29


Model Code EFV1-10-O

EFV1 – 10 * – 0 * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 5 Flow Rating 7 8

EFV1 - Electro Proportional A - 4 USgpm @ 160 PSID Material Port


Flow Control Valve B - 8 USgpm @ 160 PSID Code Code*
C - 10 USgpm @ 160 PSID Description Part Number

2
0 000 No manifold block –
Size
6 Bleed Screw and A 03B Aluminum, Light Duty 02-173358
10 - 10 Size 3/8” BSPP
Manual Override 06T Aluminum, Light Duty 566162
0 - No core tube special SAE 6
3 Seals features 02G Aluminum, 1/4” BSPP 876705
N - Buna-N S - Screw-in type manual 03G Aluminum, 3/8” BSPP 876714
®
override 06H Aluminum, SAE 6 876704
V - Viton 08H Aluminum, SAE 8 876711
S 02G Steel, 1/4” BSPP 02-175127
4 Logic 03G Steel, 3/8” BSPP 02-175128
06T Steel, SAE 6 02-175124
0 - Normally Open 08T Steel, SAE 8 02-175125
Note: Both the manifold and port plug are required.
9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve. has special features, omitted
if ”00.“)
Dimensions 44,2 (1.74)
mm (inch)
32,8 (1.29)
Torque cartridge in housing 32,0
(1.26) 19,1 (0.75)
S - 68-75 Nm
(50-55 ft. lbs)
A - 47-54 Nm
(35-40 ft. lbs)
108,7
(4.28)
86,4
(3.40)

64,0
(2.52)

47,2 3
(1.86)
2

1
Note: EFV1-10 with DIN-43650 connector Note: Port 1 is unused and must be plugged. Note - S type manual override shown
shown.

B-30 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


EFV1-10-C
Proportional flow control
valve, normally closed,
spool type

B
Description Operation
The EFV1-10-C is a normal- The valve is controlled by The maximum intended different from those
ly closed, unidirectional, current supplied to the coil. pressure drop is 300 PSID. obtained with flow from
uncompensated, spool At zero current, the valve is At pressure drops above port 3 to port 2.
type, two way, proportional fully closed from port 3 to 300 PSID, almost no Since the spool and arma-
flow control, screw-in car- port 2. At 1500 mA (12V increase in flow is obtained. ture are pressure balanced,
tridge valve. coil) the valve is considered The intended flow direction the operating pressure
fully open. This is the maxi- is from port 3 to port 2. does not affect the operat-
mum intended current level Operation of the valve with ing characteristics of the
for use in applications. Port flow from port 2 to port 3 valve. The operating point
1 is used for pressure bal- will produce flow vs current of the valve is determined
ancing the spool and arma- and flow vs pressure drop only by current, pressure
ture and must be blocked in curves that are significantly drop and temperature.
all cases.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with DTE 24 hydraulic fluid at 120°F
3 Typical application pressure 210 bar (3000 psi)
3 Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated maximum flow at 160 PSID Flow rating “A” 15.1 L/min (4 USgpm)
1
2 Flow rating “B” 30.2 L/min (8 USgpm)
1 Flow rating “C” 37.9 L/min (10 USgpm)
2
Hysteresis 1 USgpm with 400Hz PWM driver
Leakage (fully closed) 197 cm3/min (12 in3/min) at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Profile View
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)
Recommended PWM frequency 200 - 400 Hz
Coil resistance at 20°C (68°F) 4.7 ω (12V), 19.0 ω (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/16/13
Cavity C-10-3
3 Seal kit 9900225-000 (Buna-N)
9900226-000 (Viton®)
3 Viton is a registered trademark of E.I. DuPont
2

1 2

1
Note
Port 1 is unused and must
be plugged.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-31


Performance
Curves
EFV1-10*-C
Cartridge Only

Max. Flow vs Pressure Drop Max. Flow vs Pressure Drop


Flow rating "A" (Zero Current) Flow rating "B" (Zero Current)

Pressure Drop - bar Pressure Drop - bar

16 0 3.4 6.9 10.3 13.8 17.2 20.7


60 16 0 3.4 6.9 10.3 13.8 17.2 20.7
60
14 14
50 50
12 12

Fl o w - U S g p m
Fl o w - U S g p m

Fl o w - L/m i n
Fl o w - L/m i n
10 40 10 40

8 30 8 30
6 6
20 20
4 4
10 10
2 2
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pressure Drop - PSID Pressure Drop - PSID

Max. Flow vs Pressure Drop Flow vs. Current


Flow rating "C" (Zero Current)

Pressure Drop - bar

16 0 3.4 6.9 10.3 13.8 17.2 20.7


60 100
14
50
12 75
Fl o w - U S g p m

Fl o w - L/m i n

40
Fl o w %

10
50
8 30
6
20 25
4
10
2
0
0 0 0 200 400 600 800 1000 1200 1400 1600
0 50 100 150 200 250 300
Current - mA
Pressure Drop - PSID
Note
To determine operating
characteristics for the flow
rating selected, at a specific
differential pressure, first
determine maximum flow
from upper curve at the dif-
ferential pressure value.
This will be the “100%”
flow on the lower curve.
Parameters: 400 Hz PWM

B-32 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code EFV1-10-C

EFV1 – 10 * – C * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 5 Flow Rating 7 8

EFV1 - Electro Proportional A - 4 USgpm @ 160 PSID Material Port


Flow Control Valve B - 8 USgpm @ 160 PSID Code Code*
C - 10 USgpm @ 160 PSID Description Part Number

2
0 000 No manifold block –
Size
6 Bleed Screw and A 03B Aluminum, Light Duty 02-173358
10 - 10 Size 3/8” BSPP
Manual Override 06T Aluminum, Light Duty 566162
0 - No core tube special SAE 6
3 Seals features 02G Aluminum, 1/4” BSPP 876705
N - Buna-N S - Screw-in type manual 03G Aluminum, 3/8” BSPP 876714
®
override 06H Aluminum, SAE 6 876704
V - Viton 08H Aluminum, SAE 8 876711
S 02G Steel, 1/4” BSPP 02-175127
4 Logic 03G Steel, 3/8” BSPP 02-175128
06T Steel, SAE 6 02-175124
C - Normally Closed 08T Steel, SAE 8 02-175125
Note: Both the manifold and port plug are required.
9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve. has special features, omitted
if ”00.“)
44,2 (1.74)
Dimensions
mm (inch) 32,8 (1.29)
32,0
Torque cartridge in housing (1.26) 19,1 (0.75)
S - 68-75 Nm
(50-55 ft. lbs)
A - 47-54 Nm
(35-40 ft. lbs) 108,7
(4.28)
86,4
(3.40)

64,0
(2.52)

47,2 3
(1.86)
2

Note: EFV1-10 with DIN-43650 connector Note: Port 1 is unused and must be plugged. Note - S type manual override shown
shown.
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-33
EFV1-12-O
Proportional flow control
valve, normally open,
spool type

Description Operation
The EFV1-12-O is a The valve is controlled by At pressure drops above Since the spool and arma-
normally open, unidirection- current supplied to the coil. 300 PSID, almost no ture are pressure balanced,
al, uncompensated, spool At zero current, the valve increase in flow is obtained. the operating pressure
type, two way, proportional is fully open from port 2 to The intended flow direction does not affect the operat-
flow control, screw-in port 3. At 1500 to 1600 mA is from port 2 to port 3. ing characteristics of the
cartridge valve. (12V coil) the valve is fully Operation of the valve with valve. The operating point
closed. Port 1 is used for flow from port 3 to port 2 of the valve is determined
pressure balancing the spool will produce flow vs current only by current, pressure
and armature and must be and flow vs pressure drop drop and temperature.
blocked in all cases. curves that are significantly
The maximum intended different from those
pressure drop is 300 PSID. obtained with flow from
port 2 to port 3.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with DTE 24 hydraulic fluid at 120°F
2
Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
1 Rated maximum flow44,2 (1.74)
at 300 PSID Flow rating “A” 95 L/min (25.0 USgpm)
3 Flow rating “B” 104 L/min (27.5 USgpm)
32,8 (1.29)
Hysteresis 1 USgpm with 400Hz PWM driver
Profile View 19,1 (0.75)
Leakage (fully closed) 77 - 483 cm3/min (5 - 30 in3/min) at 3000 PSID
1.26
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully 86,3
close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)
Recommended(3.40)PWM frequency 200 - 400 Hz
Coil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)
64,0
Mass (2.52) Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/116/13
Cavity C-12-3
Seal kit 9900171-000 (Buna-N)
9900172-000 (Viton®)
68,6 Viton is a registered trademark of E.I. DuPont
3 (2.70) 3

2 2

1 1
Note
Port 1 is unused and must
be plugged.

B-34 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Performance
Curves
EFV1-12-0
Cartridge Only

Max. Flow vs Pressure Drop Max. Flow vs Pressure Drop


Flow rating ”A“ (Zero Current) Flow rating ”B“ (Zero Current)

Pressure Drop - bar


20 0 5 10 15 20
30 Pressure
Pressure Drop
Drop - bar
- bar Pressure
Pressure Drop
Drop - bar
- bar
100 0 0 5 5 1010 1515 2020100 0 0 5 5 1010 1515 2020
25
3030 3030
80 80100 100
- USgpm

20 100 100
Flow - L/min

- L/min
2525 2525
60 60
8080 8080
Flow - USgpm

Flow - USgpm
USgpm

Flow - USgpm
1520
20 2020
Flow - L/min

Flow - L/min
L/min

Flow - L/min
Flow -Flow
Flow -Flow

40 10 40
6060 6060
1515 1515
20 510
10 20
4040 1010 4040

0 0
5 5 0
2020 5 5 2020
300 0 50 100 150 200 250 300
0 0 Pressure Drop - PSID 0 0 0 0 0 0
0 0 5050 100100 150150 200 200 250250 300
300 0 0 5050 100100 150150 200 200 250
250 300
300
Pressure
Pressure Drop
Drop - PSID
- PSID Pressure
Pressure Drop
Drop - PSID
- PSID

Flow vs Current

100
100 Note
3030 To100
100 determine operating
80 75 100
100
Flow - L/min

2525 characteristics for the flow


Flow %

60 8080 rating
7575 selected, at a specific
Flow - USgpm
Flow - USgpm

5020 differential pressure, first


Flow - L/min
Flow - L/min

20
Flow %
Flow %

40 6060 determine maximum flow


1515 5050 upper curve at the dif-
from
25
20 4040 ferential pressure value.
1010 This will be the “100%
0 2525
0 5
5 2020 flow” flow on the lower
1600 0 200 400 600 800 1000 1200 1400 1600 curve.
0 0 Current - mA 0 0 0 0
0 0 200
200400
400600
600800
8001000 1200
1000 1400
1200 1600
1400 1600 0 0 200
200400
400600
600800
8001000 1200
1000 1400
1200 1600
1400 1600
Current - mA
Current - mA Current - mA
Current - mA
Parameters:
400 Hz PWM

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-35


Model Code EFV1-12-O

EFV1 – 12 * – 0 * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 5 Flow Rating 7 8

EFV1 - Electro Proportional A - 25.0 USgpm @ 300 PSID Material Port


Flow Control Valve B - 27.5 USgpm @ 300 PSID Code Code*
Description Part Number
0 000 No manifold block –
2 Size 6 Bleed Screw and
A 04G Aluminum, 1/2” BSPP 02-161817
12 - 12 Size Manual Override 06G Aluminum, 3/4” BSPP 02-161816
0 - No core tube special 10T Aluminum, SAE 10 02-160642
features 12T Aluminum, SAE 12 02-160646
3 Seals S - Screw-in type manual S 04G Steel, 1/2” BSPP 02-169815
N - Buna-N override 06G Steel, 3/4” BSPP 02-169814
V - Viton® 10T Steel, SAE 10 02-161070
12T Steel, SAE 12 02-169816
Note: Both the manifold and port plug are required.
4 Logic
0 - Normally Open 9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve.
has special features, omitted
44,2 (1.74) if ”00.“)
Dimensions 32,8 (1.29)
mm (inch) 19,1 (0.75)
Torque cartridge in housing 1.26
S - 136-149 Nm
(100-110 ft. lbs)
A - 108-122 Nm
(80-90 ft. lbs)
86,3
(3.40)

64,0
(2.52)

Note
EFV1-12 with DIN-43650
connector shown.

68,6
3 (2.70) 3

Note 2 2
Port 1 is unused and must
be plugged.
1 1

B-36 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


EFV1-12-C
Proportional flow control
valve, normally closed,
spool type

Description Operation
The EFV1-12-C is a nor- The valve is controlled by The maximum intended obtained with flow from
mally closed, unidirection- current supplied to the coil. pressure drop is 300 PSID. port 3 to port 2.
al, uncompensated, spool At zero current, the valve is At pressure drops above Since the spool and arma-
type, two way, proportion- fully closed from port 3 to 300 PSID, almost no ture are pressure balanced,
al flow control, screw-in port 2. At 1500 mA (12V increase in flow is obtained. the operating pressure does
cartridge valve. coil) the valve is considered The intended flow direction not affect the operating
fully open. This is the maxi- is from port 3 to port 2. characteristics of the valve.
mum intended current level Operation of the valve with The operating point of the
for use in applications. flow from port 2 to port 3 valve is determined only by
Port 1 is used for pressure will produce flow vs current current, pressure drop and
balancing the spool and and flow vs pressure drop temperature.
armature and must be curves that are significantly
blocked in all cases. different from those

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with DTE 24 hydraulic fluid at 120°F
3 Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated maximum flow at 300 PSID Flow rating “A” 55L/min (14.3 USgpm)
1 44,2 (1.74) Flow rating “B” 77 L/min (20.6 USgpm)
2
Hysteresis 32,8 (1.29) 1 USgpm with 400Hz PWM driver
Leakage (fully closed) 77 - 483 cm3/min (5 - 30 in3/min) at 3000 PSID
Profile View 19,1 (0.75)
Ambient operating temperature -30° to 90°C (-22° to 194°F)
1.26
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully close valve 1500 - 1600 mA (12V coil), 750 - 800 mA (24V coil)
Recommended 86,3 dither frequency 200 - 400 Hz
Coil resistance(3.40)
at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)
Mass 64,0 Cartridge only 0,37 kg (0.82 lb)
(2.52) Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/116/13
Cavity C-12-3
Seal kit 9900171-000 (Buna-N)
9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont
68,6
3 (2.70) 3

2 2

1 1
Note
Port 1 is unused and must
be plugged.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-37


Performance
Curves
EFV1-12*-C
Cartridge Only

Max. Flow vs Pressure Drop Max. Flow vs Pressure Drop


Flow rating ”A“ (Valve fully open) Flow rating ”B“ (Valve fully open)

Pressure Drop - bar


0 Pressure
5PressureDrop
Drop- bar
-10
bar Pressure
PressureDrop
Drop- bar
- bar
25 0 0 55 1010 90 00 55 1010
50 1515 2525 9090
80
20 5050
70 8080
40 2020
- USgpm

7070
Flow - L/min

- L/min
60
4040
15
- USgpm

Flow - USgpm
Flow - USgpm

Flow - USgpm
1010

- L/min

Flow - L/min
Flow - L/min

Flow - L/min
30 50 6060
1515
10 30
4030 5050
20 Flow
Flow

30
Flow
1010 4040
2020
Flow

10 55 5 20 3030
1010 55 2020
10
0 0 0 1010
200 000 50 100 150 2000 0 00 00
00 5050
Pressure100
100 - PSID150
Drop 150 200
200 00 5050 100
100 150
150 200
200
Pressure
PressureDrop
Drop- PSID
- PSID Pressure
PressureDrop
Drop- PSID
- PSID

Flow vs Current
(Flow rating ”B“)

100
50 1515 Note
100
100
5050 To determine operating
40 75
characteristics for the flow
Flow - L/min

4040 7575
USgpm
Flow - USgpm

rating selected, at a specific


%

Flow - L/min
Flow - L/min

30 1010
differential pressure, first
Flow %

50
Flow %
Flow -Flow

3030 determine
5050 maximum flow
20
from upper curve at the dif-
25
55 2020 ferential pressure value.
10 2525
This will be the “100%”
1010
0 0 flow on the lower curve.
400 000 200 400 600 800 1000 1200 1400 0 0 00
0 0 200
200 400 600
600 800
400 Current - mA1000
800 10001200
12001400
1400 00 200
200 400
400 600
600 800
800 1000
10001200
12001400
1400
Current
Current- mA
- mA Current
Current- mA
- mA

Parameters:
400 Hz PWM

B-38 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code EFV1-12-C

EFV1 – 12 * – C * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 5 Flow Rating 7 8

EFV1 - Electro Proportional A - 14.3 USgpm @ 300 PSID Material Port


Flow Control Valve B - 20.6 USgpm @ 300 PSID Code Code*
Description Part Number
0 000 No manifold block N/A
2 Size 6 Bleed Screw and
A 04G Aluminum, 1/2” BSPP 02-161817
12 - 12 Size Manual Override 06G Aluminum, 3/4” BSPP 02-161816
0 - No core tube special 10T Aluminum, SAE 10 02-160642
features 12T Aluminum, SAE 12 02-160646
3 Seals S - Screw-in type manual S 04G Steel, 1/2” BSPP 02-169815
N - Buna-N override 06G Steel, 3/4” BSPP 02-169814
V - Viton® 10T Steel, SAE 10 02-161070
12T Steel, SAE 12 02-169816
Note: Both the manifold and port plug are required.
4 Logic
C - Normally Closed 9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve.
has special features, omitted
44,2 (1.74) if ”00.“)
Dimensions 32,8 (1.29)
mm (inch)
19,1 (0.75)
Torque cartridge in housing 1.26
S - 136-149 Nm
(100-110 ft. lbs)
A - 108-122 Nm
(80-90 ft. lbs)
86,3
(3.40)

64,0
(2.52)

Note: EFV1-12 with DIN-43650 connector shown.

68,6
3 (2.70) 3
Note
2 2
Port 1 is unused and must
be plugged.
1 1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-39


EFV2-12-O
Proportional flow control
valve, normally open,
pressure compensated
spool type

Description Operation
The EFV2-12-O is a normal- port 2. If port 2 is blocked Current supplied to the coil downstream system pres-
ly open, three port, pres- the valve functions as a controls the valve. At zero sure. As current is increased
sure compensated, propor- restrictive, 2 way, pressure current, the valve is fully to the solenoid the flow out
tional flow control valve. compensated flow regulator. open from port 1 to port 3. of port 3 will decrease.
The valve can be used as a At 1600 mA (12V coil) the
priority flow regulator, with valve is fully closed. The
regulated flow being sup- valve will regulate flow out
plied to port 3 and excess of port 3 regardless of
flow being by-passed to

2-C Functional Symbol


EFV2-12-0 RATINGS AND SPECIFICATIONS
Performance data is typical with DTE 24 hydraulic fluid at 120°F
1 1 Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated Flow “A” Spool – Max. Regulated flow (By-Pass Mode): 53L/min (14.0 USgpm)
Max. Regulated flow (2 Port Mode): 42L/min (11.0 USgpm)
Max. Input flow: 114L/min (30.0 USgpm)
“B” Spool – Max. Regulated flow (By-Pass Mode): 38L/min (10.0 USgpm)
44,2 (1.74) Max. Regulated flow (2 Port Mode): 31L/min (8.0 USgpm)
Max. Input flow: 114L/min (30.0 USgpm)
3 2 3 32,8 (1.29) Note: Max Regulated Flow may decrease slightly during compensation.

Sectional View Hysteresis 19,1 (0.75) 1.5 USgpm max with 400Hz PWM driver
Leakage (fully closed) 240 cm3/min (15 in3/min)1.26 at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
86,3valve
Current to fully open 350 ± 100mA (12V coil), 175 ± 50 mA (24V coil)
(3.40)
Current to fully close valve 1600 ± 200 mA (12V coil), 800 ± 100 mA (24V coil)
Recommended PWM frequency 64,0 200 - 400 Hz
(2.52)
Coil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/116/13
Cavity C-12-3
Regulated Seal kit 68,6 9900171-000 (Buna-N)
Flow 3 (2.70) 3 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont
Excess 2 2
Flow

1 1
Inlet

B-40 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Performance
Curves
EFV2-12-O
Cartridge Only

B
Pressure Drop Port 1 to Port 2 Pressure Drop Port 1 to Port 3

400 180
180
400
Pressure Drop (PSI)

Pressure Drop (PSI)


350
Pressure Drop (PSI)

Pressure Drop (PSI)


350
300 150
150
300
250 BB
250 AA
200 100
100
200
150
150
100 50
50
100
50
50
00 00
00 55 10
10 15
15 20
20 25
25 30
30 0.0
0.0 2.5
2.5 5.0
5.0 7.5
7.5 10.0
10.0 12.5
12.5
GPM
GPM GPM
GPM

Flow vs Current - A Spool Flow vs Current - B Spool


Regulated Flow vs. Pressure PREG>PBYP
16 16 16 16
14 14 14 14
By-Pass
By-Pass
Mode
Mode GPM
12 12 12 12
Flow (GPM)
Flow (GPM)

A
Flow (GPM)
Flow (GPM)

10 10 10 10 By-Pass
By-Pass
Mode
Mode
8 8 8 8
2 Port
2 Port
Mode
Mode B
6 6 6 6
2 Port
2 Port
Mode C
Mode
4 4 4 4
D
2 2 2 2
E F
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000
Current
Current
(Milli-amps)
(Milli-amps) A 0 amps B 0.3 amps C 0.6 amps PSI
Current
E 1.2 amps Current
F (Milli-amps)
(Milli-amps)
D 0.9 amps 1.5 amps
Parameters:
400 Hz PWM

Regulated Flow vs Pressure Regulated Flow vs Pressure


Port 3 Pressure >Regulated Flow vs. Pressure PREG>PBYP
Port 2 Pressure Port 2 Pressure Regulated
> Port 3 Flow
Pressure
vs. Pressure PREG<PBYP

GPM GPM
15.0 15.0
A
12.5 12.5
A
10.0 10.0
B B
7.5 7.5
C C
5.0 5.0
D D
2.5 2.5
E F E
0.0 0.0 F
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500 4000
A 0 amps B 0.3 amps C 0.6 amps PSI A 0 amps B 0.3 amps C 0.6 amps PSI
D 0.9 amps E 1.2 amps F 1.5 amps D 0.9 amps E 1.2 amps F 1.5 amps
Note: Pressure Compensation curves are shown for “B” spool valves.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-41


Regulated Flow vs. Pressure PREG<PBYP
Model Code EFV2-12-O

EFV2 – 12 * – 0 * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 5 Flow Rating 7 8

EFV2 - Electro Proportional A - 14 USgpm @ 180 PSID Material Port


Flow Control Valve B - 10 USgpm @ 180 PSID Code Code*
See specifications Description Part Number
0 000 No manifold block –
2 Size
6 Bleed Screw and A 04G Aluminum, 1/2” BSPP 02-161817
12 - 12 Size 06G Aluminum, 3/4” BSPP 02-161816
Manual Override 10T Aluminum, SAE 10 02-160642
0 - No core tube special 12T Aluminum, SAE 12 02-160646
3 Seals features S 04G Steel, 1/2” BSPP 02-169815
N - Buna-N S - Screw-in type manual 06G Steel, 3/4” BSPP 02-169814
V - Viton® override 10T Steel, SAE 10 02-161070
12T Steel, SAE 12 02-169816
Note: Both the manifold and port plug are required.
4 Logic
0 - Normally Open 9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve.
has special features, omitted
44,2 (1.74) if ”00.“)
Dimensions 32,8 (1.29)
mm (inch) 19,1 (0.75)
Torque cartridge in housing 1.26
S - 136-149 Nm
(100-110 ft. lbs)
A - 108-122 Nm
(80-90 ft. lbs)
86,3
(3.40)

64,0
(2.52)

Note
EFV2-12 with DIN-43650
connector shown.

68,6
3 (2.70) 3

2 2

1 1

B-42 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


EFV2-12-C
Proportional flow control
valve, normally closed,
spool type

Description Operation
The EFV2-12-C is a nor- If port 2 is blocked the Current supplied to the coil The valve will regulate flow
mally closed, three port, valve functions as a restric- controls the valve. At zero out of port 3 regardless of
pressure compensated, tive, 2 way, pressure com- current, the valve is fully downstream system pres-
proportional flow control pensated flow regulator. closed from port 1 to port 3. sure. As current is
valve. The valve can be At 1500 to 1600 mA (12V increased to the solenoid
used as a priority flow coil) the valve is fully open. the flow out of port 3 will
regulator, with regulated increase.
flow being supplied to
port 3 and excess flow
being by-passed to port 2.

EFV2-12-C
Functional Symbol EFV2-12-0
RATINGS AND SPECIFICATIONS

1 Performance1 data is typical with DTE 24 hydraulic fluid at 120°F


Typical application pressure 210 bar (3000 psi)
Cartridge endurance rating 1 million cycles
Cartridge fatigue pressure rating (NFPA/T2.6.1 R2-2000) 210 bar (3000 psi)
Rated Flow “A” Spool – Max. Regulated flow (By-Pass Mode): 57L/min (15.0 USgpm)
Max. Regulated flow (2 Port Mode): 53L/min (14.0 USgpm)
Max. Input flow: 114L/min (30.0 USgpm)
“B” Spool – Max. Regulated flow (By-Pass Mode): 38L/min (10.0 USgpm)
44,2 (1.74) Max. Regulated flow (2 Port Mode): 31L/min (8.0 USgpm)
2 3 2 3 Max. Input flow: 114L/min (30.0 USgpm)
32,8 (1.29) Note: Max Regulated Flow may decrease slightly during compensation.

Profile View Hysteresis 19,1 (0.75) 1.5 USgpm max with 400Hz PWM driver
Leakage (fully closed) 240 cm3/min (15 in1.263
/min) at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully 86,3
open valve 1600 ± 200 mA (12V coil), 800 ± 100 mA (24V coil)
(3.40)
Current to fully close valve 350 ± 100 mA (12V coil), 175 ± 50 mA (24V coil)
Recommended dither frequency64,0 200 - 400 Hz
(2.52)
Coil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/116/13
Cavity C-12-3
Seal kit 68,6 9900171-000 (Buna-N)
3 (2.70) 3 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont
2 2

1 1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-43


Performance
Curves
EFV2-12*-C
Cartridge Only

Flow vs Pressure Drop Flow vs Pressure Drop


Excess flow P1 to P2 (P3 to Atm) Regulated flow P1 to P3 (P2 to Atm)
Full current (1700 mA on a 12V Coil) Full current (1700 mA on a 12V Coil)

400 180
350
300 150

Pressure Drop - psi


Pressure Drop psi

250
B
200 100
150
A
100 50
50
0
0
0 5 10 15 20 25 30 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Flow-US gpm Flow-US gpm
A - A spool pressure drop
B - B spool pressure drop

Flow vs Current

18 A - A spool
16 B - B spool
14 2 Port
By-Pass Mode Mode
12
Flow (GPM)

10 By-Pass
Mode
8
6
A 2 Port Mode
4
B
2
0
0 200 400 600 800 1000 1200 1400 1600 1700
Current (mA)

Regulated Flow vs Pressure Regulated Flow vs Pressure


Regular to Bypass Bypass to Regular

20.0 20.0
17.5 G 17.5 G
15.0 15.0
Flow-US gpm

F F
Flow-US gpm

12.5 E 12.5 E
10.0 D 10.0
D
7.5 7.5
C C
5.0 5.0
2.5 B 2.5 B
0.0 A 0.0 A

0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Pressure - psi Pressure - psi
A - 0.3 AMPS B - 0.6 AMPS C - 0.9 AMPS A - 0.3 AMPS B - 0.6 AMPS C - 0.9 AMPS
D - 1.2 AMPS E - 1.5 AMPS F - 1.8 AMPS D - 1.2 AMPS E - 1.5 AMPS F - 1.8 AMPS
G - 2.0 AMPS G - 2.0 AMPS

Note: Pressure Compensation curves are shown for “B” spool valves.

B-44 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code EFV2-12-C

EFV2 – 12 * – C * * – * *** – *****E** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 5 Flow Rating override


7 8
EFV2 - Electro Proportional A - 15 USgpm @ 180 PSID
Flow Control Valve B - 10 USgpm @ 180 PSID Material Port
See Specifications Code Code*
Description Part Number
2 Size
6 Bleed Screw and
0 000 No manifold block N/A
12 - 12 Size A 04G Aluminum, 1/2” BSPP 02-161817
Manual Override
06G Aluminum, 3/4” BSPP 02-161816
0 - No core tube special 10T Aluminum, SAE 10 02-160642
3 Seals features 12T Aluminum, SAE 12 02-160646
N - Buna-N S - Screw-in type manual S 04G Steel, 1/2” BSPP 02-169815
V - Viton® 06G Steel, 3/4” BSPP 02-169814
10T Steel, SAE 10 02-161070
12T Steel, SAE 12 02-169816
4 Logic
C - Normally Closed Note: Both the manifold and port plug are See Section C.
required. * These model digits will not be stamped
on the valve.

9 Coil Model Code* 10 Special Features


00 - None
44,2 (1.74)
Dimensions (Only required when valve
mm (inch) 32,8 (1.29) has special features, omitted
Torque cartridge in housing 19,1 (0.75) if ”00.“)
1.26
S - 136-149 Nm
(100-110 ft. lbs)
A - 108-122 Nm
(80-90 ft. lbs)

86,3
(3.40)

64,0
(2.52)
Note: EFV2-12 with DIN-43650 connector shown.

68,6
3 (2.70) 3

2 2

1 1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-45


C

Coils and Electronic Controls


Solenoid valve and Proportional valve coils and electronic controls for proportional valves

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-1


Section Contents
Coils and Electronic Controls

Description Application Page


Coils
ToughCoils™ Information ..................................................................................................................................................C-3
ToughCoils™ Model Code and Specifications ....................................................................................................................C-4
S Series ............................................................for 8 size solenoid valves ............................................................ C-5
P Series ............................................................for 8 size solenoid valves ............................................................ C-5
J Series ............................................................for 10,12,16, 20 size solenoid valves ............................................ C-6
H Series ............................................................for 10,12,16, 20 size solenoid valves ............................................ C-6
Coil Dimensions ................................................S & P Series Coils ..........................................................................C-7
Coil Dimensions ................................................J Series Coils ..................................................................................C-8
Coil Dimensions ................................................H Series Coils..................................................................................C-9
R & L Series coils ....................................................for 12 size 3 & 4 way solenoid valves ..........................................C-10
Explosion proof valve coils ......................................for SV*E series valves ..................................................................C-11
EPV proportional valve coils ..........................................................................................................................................C-13
EFV proportional valve coils ............................................................................................................................................C-14
Proportional Valve Drivers
Power Plugs for Proportional valves ........................EHH-AMP-702-D/J/K-2* Series ....................................................C-15
“Soft Switch” Power Plugs ....................................EHH-AMP-702-C-2* 10 Series ......................................................C-21

C-2 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


ToughCoils™
Information

ToughCoils™
C

Vickers ToughCoils have integrated connectors are leads. and industrial applications.
been designed to provide rated up to IP69K environ- The best in class, one-
industry leading environ- mental protection. piece, shell encapsulated, The exclusive compact coil
mental protection and sole- ToughCoils™ are available design meets the most design from Vickers, offers
noid performance in a with a variety of popular stringent environmental the advantage of field retro-
compact and rugged pack- integrated connection requirements for mobile fit-ability on all existing, and
age. ToughCoils™ with options and with wire new, applications.

Toughcoils™ Features

• IP69K Environmental • “Thermal Shock Dunk” • Field Retrofit-able • Steel Shell Encapsulated
Protection - This rating Test - Vickers ToughCoils ToughCoils™ replace all Design ToughCoils™ pro-
provides protection have been qualified to current Vickers coils used vide protection against
against the ingress of withstand the toughest on D Frame and Shell physical and environmen-
dust and high pressure Mobile Equipment type coils. Compact coil tal damage.
jet stream. The IP69K “Thermal Shock Dunk” dimensions allow substi-
test was designed tests. Integrated tution in all existing appli-
specifically for rating pro- Deutsch, MetriPack1 and cations. ToughCoils are
tection against a high- Leadwire2 connectors available for most 8, 10,
pressure jet stream, high exceed “Thermal Shock 12, 16 and 20 series
liquid temperature and Dunk” test qualifications valves. No additional
close nozzle distance at 140°C. The “Thermal water/weather proofing
from the enclosure sur- Shock Dunk” test is required.
face. IP69K protection is requires coils to be heat-
standard on coils with ed, reaching a stabilized
MetriPac or Deutsch, temperature of 100°C,
integrated connectors. then immediately
immersed in a solution at
0°C. The thermal shock
is repeated five times
with the coil monitored
for dielectric strength in
the solution and function-
al performance is verified.
In addition, ToughCoils™
passed a more severe
powered dunk test con-
Vickers ToughCoils™, ducted from 100°C to
with rated connector, 0°C with 115% rated
meet or exceed all major voltage applied.
OEM environmental pro-
1
MetriPack® 150 and MetriPack® 280
are registered trade marks of Delphi
tection requirements Packard Electric Systems
2
Coils with integrated connectors are
recommended for applications in harsh
environments.

Shown with deutsch connection options

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-3


ToughCoils
Model Code
S, P, J and H Series Coils

MCSC – * – *** – * – ** – * – ** – 10

1 2 3 4 5 6 7 8

Product Voltage Type D0 - MetriPack® 150 Male,


MCSC - Solenoid Coil D - DC 0 - None
1 4 6 Lead Length

B - DC / with flyback diode A - 152mm [6.0 in]


Integrated (DC Only)

Series A - AC / with full bridge


Mating Connector:

S - Size 8 [210 Bar] J0 - MetriPack® 280 Male,


2 Delphi 12052641 (Standard length with

P - Size 8 [350 Bar] B - 610mm [24.0 in]


rectifier connector)

J - Size 10, 12, 16, 20


Integrated (DC Only)

G0 - ISO 4400 DIN


5 Mating Connector:

E0 - Weather–Pack (Packard)
Connector (Standard length

H - Size 10, 12, 16, 20


[210 Bar] Delphi 15300027 without connector)

Q0 - Spade Terminals Special Features


43650

W0 - Leadwire
[350 Bar] female on wire leads 7

Voltage Rating N0 - Deutsch Male,


Mating Connector:

F0 - Weather–Pack (Packard)
00 - No Special Features

012 - 12 Volt Design Code


3 Delphi 12010973

024 - 24 Volt
DT04-2P, Integrated 8

036 - 36 Volt
(DC Only) Mating male on wire leads
10 - Design Code

048 - 48 Volt
Connector: Deutsch Mating Connector:

115 - 115 Volt Y0 - Amp Jr (DC Only)


DT06-2S Delphi 12015792

230 - 230 Volt


Note: Auxiliary parts for mating
connectors may be required.
Mating Connector:
Note: Please refer to the follow pages AMP 963040-3 or
for preferred coil configuration equivalent

Specifications
RATINGS AND SPECIFICATIONS
Duty Rating Continuous from 85% to 110% of nominal voltage
Operating temperature 100°C (212°F) continuous @ nominal voltage
Lead Wires 18 gauge, standard 610 mm (24”) long, UL style 3173 CSA CL 1251
(meets SAE J1128 XLPE style SXL)
Power Rating S Series: 20W
P Series: 23W
J Series: 23W
H Series: 29W
Encapsulent Glass filled nylon
Magnet Wire U.L. class N, 200°C (392°F) NEMA pub. No. MW 1000, section MW 35–C (single)
Flyback diode (arc suppressor) Maximum recurrent peak reverse voltage – 800 V (optional)

Environmental Protection
CONNECTOR IP65 IP67 IP69K THERMAL SHOCK DUNK
G0: DIN 43650 X*
Q0: Spade
Y0: Amp Jr. X X1*
W0: Wire Leads X X X1
N0: Deutsch X X X X
D0: Metri-Pack 150 X X X X
J0: Metri-Pack 280 X X X X
1 Passed environmental testing, but not as robust as other connectors
* Rating dependent on mating connector
CAUTION
∑ Coils may be hot to
touch if used in
continuous duty applications.

C-4 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


ToughCoils
For 8 Size Solenoid Valves S & P Series Coils

S Series ToughCoils part numbers - 300AA00____ (Complete Part number is 11 Digits)


G0** Q0 W0 N0 Y0 D0 J0
VOLTAGE CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR
12VDC 001A 009A 015A 021A 026A 031A 036A
C
24VDC 002A 010A 016A 022A 027A 032A 037A
36VDC 003A 011A 017A 023A 028A 033A 038A
24VAC 004A 012A 018A – – – –
115VAC 005A – – – – – –
230VAC 006A – – – – – –
12VDC* 007A 013A 019A 024A 029A 034A 039A
24VDC* 008A 014A 020A 025A 030A 035A 040A
*With flyback diode. (Voltage Type B) **DIN 43560 mating connector for “G0” style coil – 02-166796.
For other voltages and connectors contact your Eaton representative.

STD.
VOLTAGES AMPERES*
12 DC 1.67 Voltage Type B
24 DC 0.83 (+) (-)
36 DC 0.56
24 AC 0.93
115 AC 0.19
230 AC 0.10
*Nominal voltage 25°C (77°F).

P Series ToughCoils part numbers - 300AA00____ (Complete Part number is 11 Digits)


G0** Q0 W0 N0 Y0 D0 J0
VOLTAGE CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR
12VDC 041A 049A 055A 061A 066A 071A 076A
24VDC 042A 050A 056A 062A 067A 072A 077A
36VDC 043A 051A 057A 063A 068A 073A 078A
24VAC 044A 052A 058A – – – –
115VAC 045A – – – – – –
230VAC 046A – – – – – –
12VDC* 047A 053A 059A 064A 069A 074A 079A
24VDC* 048A 054A 060A 065A 070A 075A 080A
*With flyback diode. (Voltage Type B) **DIN 43560 mating connector for “G0” style coil – 02-166796.
For other voltages and connectors contact your Eaton representative.

STD.
VOLTAGES AMPERES*
Voltage Type B
12 DC 1.92
(+) (-)
24 DC 0.96
36 DC 0.64
24 AC 1.06
115 AC 0.22
230 AC 0.11
*Nominal voltage 25°C (77°F).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-5


ToughCoils
For 10, 12, 16 and 20 Size J & H Series Coils
Solenoid Valves

J Series ToughCoils part numbers - 300AA00____ (Complete Part number is 11 Digits)


G0** Q0 W0 N0 Y0 D0 J0
VOLTAGE CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR
12VDC 081A 089A 095A 101A 106A 111A 116A
24VDC 082A 090A 096A 102A 107A 112A 117A
36VDC 083A 091A 097A 103A 108A 113A 118A
24VAC 084A 092A 098A – – – –
115VAC 085A – – – – – –
230VAC 086A – – – – – –
12VDC* 087A 093A 099A 104A 109A 114A 119A
24VDC* 088A 094A 100A 105A 110A 115A 120A
*With flyback diode. (Voltage Type B) **DIN 43560 mating connector for “G0” style coil – 02-166796.
For other voltages and connectors contact your Eaton representative.

STD.
VOLTAGES AMPERES*
12 DC 1.92 Voltage Type B
24 DC 0.96 (+) (-)
36 DC 0.64
24 AC 1.06
115 AC 0.22
230 AC 0.11
*Nominal voltage 25°C (77°F).

H Series ToughCoils part numbers - 300AA00____ (Complete Part number is 11 Digits)


G0** Q0 W0 N0 Y0 D0 J0
VOLTAGE CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR
12VDC 121A 129A 135A 141A 146A 151A 156A
24VDC 122A 130A 136A 142A 147A 152A 157A
36VDC 123A 131A 137A 143A 148A 153A 158A
24VAC 124A 132A 138A – – – –
115VAC 125A – – – – – –
230VAC 126A – – – – – –
12VDC* 127A 133A 139A 144A 149A 154A 159A
24VDC* 128A 134A 140A 145A 150A 155A 160A
*With flyback diode. (Voltage Type B) **DIN 43560 mating connector for “G0” style coil – 02-166796.
For other voltages and connectors contact your Eaton representative.

STD.
VOLTAGES AMPERES*
Voltage Type B
12 DC 2.42
24 DC 1.21 (+) (-)
36 DC 0.81
24 AC 1.34
115 AC 0.28
230 AC 0.14
*Nominal voltage 25°C (77°F).

C-6 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


S and P Series
Dimensions
Coils

34,3 [1.35] 29,5 [1.16] C


28,0 [1.10]

31,8 [1.25] 12,9 [.51]


39,7 [1.56]

G0 Shown with integrated Deutsch Connector


DIN 43650-A Connector

34,5 [1.36] 29,5 [1.16]


17,5 [0.69]
26,2 [1.03] 26,2 [1.03]

28,0 [1.10]

Q0 W0
Spade Connector Leadwire

37,1 [1.46] 35,6 [1.40]

31,2 34,8 [1.37]


[1.23] 23,4
[.92]
24,9 [.98] 27,9 [1.10]

N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior Timer integrated connector

35,1 [1.38] 37,6 [1.48]

29,7 33,9
[1.17] 24,1 [.95] [1.33] 25,4 [1.00]

D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-7


J Series Coils
Dimensions

33,5 [1.32]
(.685) 29,5 [1.16]

31,5 [1.24]

Ø 38,9 [1.53] 12,9 [.51]


46,5 [1.83]

G0 Shown with integrated MetriPack 150 Connector


DIN 43650-A Connector

34,3 [1.35] 29,5 [1.16]


(.685)
26,2 [1.03]

29,7 [1.17]

31,5 [1.24]

Q0 W0
Spade Connector Leadwire

35,3 [1.39]
36,8 1.45] 5,1 [.20]

34,8 38,4 [1.51]


28,4 [1.12] 31,5 [1.24]
[1.37]

N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior Timer integrated connector

35,1 [1.38] 37,6 [1.48]

33,3 37,3
[1.31] 27,7 [1.09] [1.47] 28,9 [1.14]

D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector

C-8 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


H Series Coils
Dimensions

33,5 [1.32] C
(.685) 29,5 [1.16]

31,5 [1.24]

Ø 38,9 [1.53] 17,6 [.69]


46,5 [1.83]

G0 Shown with integrated MetriPack 280 Connector


DIN 43650-A Connector

34,3 [1.35] 29,5 [1.16]


(.685)
26,2 [1.03]

29,7 [1.17]

31,5 [1.24]

Q0 W0
Spade Connector Leadwire

35,3 [1.39]
36,8 1.45] 5,1 [.20]

34,8 38,4 [1.51]


[1.37] 28,4 [1.12] 31,5 [1.24]

N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior Timer integrated connector

35,1 [1.38] 37,6 [1.48]

33,3 37,3
[1.31] 27,7 [1.09] [1.47] 28,9 [1.14]

D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-9


R & L Series
Coils
For SVx-12-3 and SVx-12-4
Solenoid Valves

L Series Coils (“EN490” Coils)


DC Coils Connector
VOLTAGE “G” DIN 43650 CONNECTOR “W” LEADWIRES ONLY
Full Power Coils:
12V 02-309454 02-309452
24V 02-309455 02-309453
NOTE: For more information on “L” series coils, please refer to Eaton Technical datasheet 5049/EN/0596/A (Solenoid Operated Directional Valve-DG4V-35, EN490 for Mobile Equipment).

R Series Coils (Blue Coils)


DC Coils Connector
VOLTAGE “G” DIN 43650 CONNECTOR “Q” SPADE CONNECTOR “W” LEADWIRES ONLY
Full Power Coils:
12V 507847 02-111166 02-140394
24V 507848 02-111168 02-140395
NOTE: For more information on “R” series coils, please refer to Eaton Technical datasheet GB-C-2015 (Solenoid Operated Directional Valve-DG4V-35 and DG4V3 Series).

R and L Series Coils


POWER CONSUMPTION
DC solenoids at rated voltage and 20˚C (68˚F)
Full Power Coils:
12V 30W
24V 30W

C-10 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Explosion
Proof Valves
For hazardous
environments
Coil Options
(SV*E Series)

SPECIFICATIONS
Hydraulic Performance Specifications for explosion proof valves are the same as the base valve.
For details please refer to the base valve page reference.
Coil Temperature Range -40° to 100°C (-40° to 212°F) C
Coil Duty Continuous from 85% to 110% of nominal voltage
Housing Type Explosion proof version with 1/2" threaded conduit hub
Coil Type Epoxy encapulated lead wire coil
Lead Wire 24" Long, 18 gauge with 1/32" cross linked Polyethylene insulation
APPROVALS
UL File AU2206, Component - Industrial truck accessory, Battery powered
CSA Both for general purpose and Hazardous locations
Class I, Group C & D
Class II, Group E, F & G

SUMMARY
Typical
Application Base
Pressure Rated flow Valve Section
Model Code Description psi (bar) l/min (Usgpm) design Reference
SV1E-10-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 45 (12) SV1-10-C A
SV2E-10-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 23 (6) SV2-10-C A
SV3E-10-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 45 (12) SV3-10-C A
SV4E-10-C-XX-XXXXU 2 way, 2 position, normally closed, spool type 210 (3000) 23 (6) SV4-10-C A
SV1E-16-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 132 (35) SV1-16-C A
SV2E-20-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 227 (60) SV2-20-C A
SV4E-10-0-XX-XXXXU 2 way, 2 position, normally open, spool type 210 (3000) 23 (6) SV4-10-0 A
SV3E-10-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 45 (12) SV3-10-0 A
SV5E-10-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 45 (12) SV5-10-0 A
SV3E-16-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 132 (35) SV3-16-0 A
SV3E-20-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 227 (60) SV3-20-0 A
SV1E-10-3-XX-XXXXU 3 way, 2 position, spool type 210 (3000) 23 (6) SV1-10-3 A
SV1E-10-4-XX-XXXXU 4 way, 2 position 210 (3000) 23 (6) SV1-10-4 A
SV2E-10-4-XX-XXXXU 4 way, 2 position, circuit center 210 (3000) 23 (6) SV2-10-4 A
SV3E-10-4-XX-XXXXU 4 way, 2 position, normally open 210 (3000) 23 (6) SV3-10-4 A
SV4E-10-4-XX-XXXXU 4 way, 2 position, tandem center 210 (3000) 23 (6) SV4-10-4 A
REPLACEMENT COIL PART NUMBERS
Voltage Assembly Number Amperes (A) Power (W) Lead Color
12 VDC 888831 1.50 20 Red
24 VDC 888832 0.75 20 Black
36 VDC 888834 0.50 20 Blue
48 VDC 888835 0.38 20 Purple
110 VDC 888836 0.16 20 Brown
24 VAC 888837 0.75 20 Orange
115 VAC 888838 0.16 20 Yellow
230 VAC 888840 0.08 20 Red/White
480 VAC 888841 0.04 20 Black/White

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-11


Explosion Proof
Valves
(SV*E Series) Model Code

SV*E – ** (V) – * – *** – **** U

1 2 3 4

1 Base Valve 2 Port Size/Housing 3 Voltage*


SV1E-10-C SV1-10-C number CODE VOLTAGE REPLACEMENT COIL
SV2E-10-C SV2-10-C Refer to table in Model Code PART NUMBER
SV3E-10-C SV3-10-C for Base valves 12D 12 VDC 888831
SV4E-10-C SV4-10-C 24D 24 DVC 888832
4 Type (C.S.A. Approved)
SV1E-16-C SV1-16-C 36D 36 VDC 888834
SV2E-20-C SV2-20-C U - 1/2" NPT Connector 48D 48 VDC 888835
Class I, Group C & D
SV4E-10-0 SV4-10-0 110D 110 VDC 888836
Class II, Group E, F & G
SV3E-10-0 SV3-10-0 24A 24 VAC 888837
SV5E-10-0 SV5-10-0 115A 115 VAC 888838
SV3E-16-0 SV3-16-0 230A 230 VAC 888840
SV3E-20-0 SV3-20-0 460A 460 VAC 888841
SV1E-10-3 SV1-10-3 * Arc suppression diode is not available.
SV1E-10-4 SV1-10-4
SV2E-10-4 SV2-10-4
SV3E-10-4 SV3-10-4
SV4E-10-4 SV4-10-4 50,8
For performance specifications refer
(2.0)
to base valve data sheet.
Viton® seal options are available.

53,9 31,8
(2.125) (1.250)
Dimensions
mm (inch)

Note "U" 0.5" N.P.T. Connector


(24" Long Leads 18 GA.)
Cartridge only or coil
housing are not available
as service parts.
It is not possible to con- 68,3
(2.69)
vert standard valves to
explosion proof variants.
SV1E-10-3 shown.
Dimensions of coil hous- 1.31 Hex
ing are the same for all
Vickers explosion proof
SiCV valves, for other
dimensions please refer
to base valve datasheet.

C-12 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


EPV Series EPV Coils
Proportional
Valve Coils

CONTROL AND SPECIFICATIONS


C
Rheostat 12 VDC operation 10-12 Ω, 20-25 watts
24 VDC operation 25-30 Ω, 20-25 watts
Power plug options EHH-AMP-702, EPAD-SA-1A6-10
(Require 24 VDC power supply to power plug and 12 VDC coil)
Amplifier card EEA-PAM-523
(Requires 24 VDC power supply and either 12VDC or 24 VDC coil)
Joystick suppliers OEM Controls, Inc, Shelton, CT
P-Q Controls, Inc, Bristol, CT

Std. Voltages Amperes* Lead Color Power Rating


12 DC 1.32 red 16 W
24 DC .66 black 16 W
*Nominal voltage @ 25°C (77°F).

Coil part numbers


F Q U* W Y
VOLTAGE CONNECTOR CONNECTOR CONNECTOR CONNECTOR CONNECTOR
12VDC 02-308810 02-317154 02-154070 02-154072 02-308808
24VDC 02-308811 02-317155 02-154071 02-154073 02-308809
*DIN 43650 mating connector for “U” style coil – 02-166796.

Coil Configurations “F”- Weather-Pack ”Q“ - Spade terminal ”U“– DIN 43650
male on leads

”W“ 610 mm “Y”- Metri-Pack Note: Width –


(24 inch) lead wire 150 male on leads all configurations
Ø 43,5
(1.71)

CAUTION
∑ Coils may be
hot to touch
if used in continuous
duty applications.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-13


EFV Series EFV
Proportional E Series Coils
Valve Coils

CONTROL AND SPECIFICATIONS


Power plug options EHH-AMP-702, EPAD-SA-1A6-10
(Require 24 VDC power supply to power plug and 12 VDC coil)
Amplifier card EEA-PAM-523
(Requires 24 VDC power supply and either 12VDC or 24 VDC coil)
Joystick suppliers OEM Controls, Inc., Shelton, CT
P-Q Controls, Inc., Bristol, CT

SPECIFICATIONS CAUTION
Standard Voltage Resistance Power Coils may be

12 VDC 4.7 Ω 30 W hot to touch if
24 VDC 19.0 Ω 30 W used in continuous
duty applications.

Coil Model Code SC – *** – * – * – E – **

1 2 3 4 5 6

Model code positions 2, 3, 4, 5 and 6 are integrated into EFV model code when ordered with valve.

1 SC Solenoid Coil 3 Protection 4 Connection 5 Series

D - Standard DC coil G - DIN 43650* E - EFV series coil


2 Voltage B - DC coil with flyback diode W - Leadwire - 24”
E - Weather-Pack female on 6 Special Features
012 - 12VDC
024 - 24VDC wire leads - 6” 00 - None
C - Deutsch DT0402P wire
leads - 6”
H - Metri-Pack 150 wire
leads - 6”
*DIN 43560 mating connector for “G”
style coil – 02-166796.

Coil Kits “W” - 610 “C” - Deutsch “E” - Weather- “H” - Metri-
mm (24 inch) DT0402P on Pack female Pack 150 male
“G” - DIN 43650 lead wire leads on leads on leads
54,1 50,3
STANDARD COIL PART
(2.13) (1.98)
NUMBERS
Model Code Assembly
Number 56,134
(2.21)
SC-012BGE00 4995052-230
SC-012BWE00 4995052-231
SC-012DGE00 4995052-001
SC-012DWE00 4995052-002
Ø 44,2
SC-024BGE00 4995052-232 (1.74)
SC-024BWE00 4995052-233 Note: Width all
Ø 20,7 configurations
SC-024DGE00 4995052-003 (0.815)
SC-024DWE00 4995052-004

C-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Electronic
Controls
Proportional Valve
Control Power Plugs

EHH-AMP-702-D/J/K-2* This plug/valve combination Features and Benefits Application


Series offers very low cost solu- • Integral amplifier pro- Primary applications are C
For use with valve types: tions to many hydraulic con- vides essential functions in the control of non-
trol problems requiring pro- for control of proportional feedback proportional valves
EPV**-12D-1* portional control. valves where the cost
EFV1-**-012DE* Type D is controlled with a of more sophisticated
• Adjustable ramp time
ERV1/2**-12D-1* 0-10V command signal, and (types D and K), gain, electronic controls can
has adjustable gain, ramp, deadband compensation be avoided.
EPRV1**-12D-1*
deadband compensation and dither Type J is typically used in
and dither. closed-loop applications.
General Description • Ease of installation, with
Type J, designed for reduced cost
Three types of plugs,
closed-loop applications,
conforming to ISO • Fully short-circuit and
is controlled with a 0-10V
4400/DIN 43650 interface, reverse-polarity protected
command signal, and has
with integral amplifiers and
no ramp function. • Differential voltage com-
necessary adjustment
potentiometers, are Type K is controlled with a mand signal (types D
designed for use with non- 4-20 mA command signal, and J)
feed back hydraulic valves. and has an adjustable ramp • Adjustable dither
time of 50 ms to 5s.
• EMC to latest European
standards
• Protection to IP67

Electrical Block Diagram Power input


1
EHH-AMP-702-D/J/K-2* 24V DC + Dither X1
0V –
2 Max. Power
PWM amp. Solenoid
Gain limiter
3 ? X2
+ Ramp*
Command Deadband
signal

4

* Type J does not have the ramp function.

Note
This product has been designed and tested to meet spe-
cific standards outlined in the European Electro-magnetic
Compatibility Directive (EMC) 89/336/EEC, amended by
91/26/EEC, 92/31/EEC and 93/68/EEC, article 5. For
instructions on installation requirements to achieve
effective protection levels, see this leaflet and the
Installation Wiring Practices for Vickers Electronic Products
leaflet 2468. Wiring practices relevant to this Directive are
indicated by a warning symbol and Electromagnetic
Compatibility (EMC).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-15


Model Code/
Operating Data

EHH – AMP – 702 – * – 2* 1 Adjustment range 2 Design number, 20 series


D - Proportional plug: Subject to change. Installation
0 - 10 VDC with ramp dimensions unaltered for
1 2 J - Proportional plug: 0 - 10 design numbers 20 to 29
VDC without ramp inclusives.
function
K - Proportional plug:
4-20 mA with ramp
OPERATING DATA
Electrical
Types D and J Type K
Connections
1 24V DC
2 OV (power and signal)
3 Positive command signal
4 Negative command signal
Power (input) supply 20-30V DC including ± 10% maximum ripple
(peak-to-peak)
24V DC nominal
Absolute maximum voltage 40V
Max. power consumption 35W
including solenoid
Reverse polarity protected Yes
Short circuit protected Yes
Maximum output current 1,6A
Maximum output voltage typical Typically 1,5V below supply voltage
(1,6A output current)
Command signal 0-10V (10 kohms) 4-20 mA (250 ohms)
Deadband triggering 200 mV 4 mA
For output (LED on) 200 mV to 10V 4-20 mA
For no output (LED off) 0 mV to 100 mV 0-4 mA
Deadband adjustment range 100 to 1000 mA
Gain adjustment range 0.02A/V to 0.16A/V 0.01 A/mA to 0.08 A/mA
Dither adjustment range 0 to 500 mA
Ramp time (types D and K only) 50 ms to 5s
PWM frequency 1200 Hz ± 10%
Dither frequency 120 Hz ± 10%
Protection IEC 529: IP67 (when correctly installed with interface seal in place)
Fully short-circuit and reverse-polarity protected
Isolation to VDE 0110 Group “B”
Electromagnetic compatibility (EMC):
Emission EN 50081-2
Immunity EN 50082-2

Mechanical
Housing PA6 glass-reinforced plastic (conforming to UL-94HB). Color: gray
Mounting interface ISO 4400 (DIN 43650)
Cable clamp Pg9 screw type
Cable diameter Ø 5 to 10 mm (0.197 to 0.394” dia.)
Wire section 0,5 to 1,0 mm2 (20-17 AWG)
Temperature, ambient range -20° to +70°C (-4° to +158°F)
Mass 0,07 kg (0.154 lb)

C-16 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Installation Data

Input/Output
Characteristics C

Type K and D Type J


Command signal Command
signal
Type K Type D voltage U s
20 mA 10V 10V
8V 8V
12 mA 6V 6V
4V 4V
2V 2V
4 mA Time Time

Output Ramp Output


current setting current

USX USX
Gain setting Gain setting
Deadband Deadband
compensation compensation
Time Time

Installation Dimensions
mm (inch)

88 (3.52) 3rd angle


22 projection
(0.87)

39 Solenoid Connections
(1.54)
No connection
1 (or 2)

34
(1.34)
2

2 (or 1)
38
(1.5)
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-17


Installation Data

Adjustments Gain Deadband


Ramp time: Turn clockwise Terminal 1: Power Supply Ramp Dither
to increase ramp time 20V-30V DC, positive.
(Only types D/K). Terminal 2: Power Supply
Gain: Turn clockwise to 0V.
increase gain. Terminal 3: Command
Deadband compensation: signal positive (see
Turn clockwise to increase ”Operating Data“).
deadband compensation Terminal 4: Command
current. signal negative (see LED
Dither: Turn clockwise to ”Operating Data“).
increase the dither current.

4 3 2 1

Installation Wiring Options


Positive Command Voltage Bi-polar Command Voltage for Operating
Two Solenoids from One Signal
+10V EHH-AMP-702-D/J-20 EHH-AMP-702-D/J-20
4 3 2 1

4 3 2 1
24V 24V
0V 0V
P
0V 0V
+10V

Negative Command Voltage


EHH-AMP-702-D/J-20 EHH-AMP-702-D/J-20

4 3 2 1
4 3 2 1

–10V 24V –10V 24V


0V 0V
0V 0V

4-20 mA Command Signal Connections when replacing –10 design power plug
EHH-AMP-702-K-20 with –20 design and only 3 wires exist
EHH-AMP-702-D/J/K-20
4 3 2 1

24V
0V
4 3 2 1

24V
4-20 mA 0V
0V 0V

Link pin 2 to pin 4


Protective ground connection.

WARNING
Electromagnetic Compatibility (EMC) - Screened cables should be used and particular
• attention paid to the grounding of the screens as shown in the above diagrams.

C-18 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Installation Data

Assembly Showing
Wiring Connection C
Points

WARNING
Ensure cable
• clamp nut is ade-
* quately tightened to secure
cable. Do not connect, or
disconnect, the plug while
power is on. Do not mount,
or dismount, the plug while
power is on.

Wiring Preparation
4 x 0.5-1.0 mm 2
(20 AWG-17 AWG)

5 (0.2)
Ø 5-10 (0.197-0.394 dia)

40 (1.6)

*All seals must be fitted correctly at plug installation to provide protection to IP67 (IEC 529).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-19


Installation Data

Start-Up Procedure • Switch off power supply Spare Parts


• Correctly wire the plug and command/input sig- The only spare part avail-
and, before mounting it nal and then install plug able is the interface seal,
on the valve solenoid, on solenoid. Ensure that part number 732100.
apply 24V DC (20 to 30V all seals are fitted cor-
limits) to the “power rectly and clamped as Ordering Procedure
input” terminals. the retaining screw is
tightened: this is essen- Order plug by full model
• Check for correct plug tial in providing IP67 code, and spare interface
function by illumination/ protection. seals by part number
non-illumination of the 732100.
LED. The LED should • Ensure that the hydraulic
illuminate when the system will not cause
demand applied to the any erratic movement of
“signal input” terminal is actuators, then:
between 200 mV and – Switch on power
10V (or 4 mA and 20 mA) supply again.
and should not be illumi- – Repeat LED/function
nated when the applied check as in 2.
demand is less than 100
mV (4 mA). If there is a An LED malfunction now
malfunction a new plug indicates a short circuit at
must be fitted. the load.
• Successful completion of
these checks means that
the plug and load are
ready for use.

C-20 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Electronic
Controls
“Soft Switch” Power
Plugs

EHH-AMP-702-C-2* The soft switch plug is Features and Benefits Application


10 Series rated for 24V DC nominal • Integral amplifier pro- Focus applications for this C
For use with valve types: and controlled by a 24V vides control from on/off plug are in the control of
logic signal. Applying an logic command signal hydraulic solenoid operated
EPV**-12D-1* “on” signal causes the out-
• Adjustable ramp time directional and pressure
EFV1-**-012DE* put current to ramp up to, control valves where con-
and stay at, an adjustable • Deadband compensation trol of valve response time
ERV1/2**-12D-1*
maximum while the “on” can significantly reduce
EPRV1**-12D-1* • Adjustable output level
signal is maintained. At shocks in the hydraulic
“switch-off” the output • Adjustable dither
system.
General Description current is ramped down to • EMC to latest European
zero and will remain at zero Best results in reducing
These plugs, conforming standards
until the next “on” signal. hydraulic shocks will only
to ISO 4400/DIN 43650 • Improved switching time be obtained by using valves
interface, offer adjustable, Ramp times (switching repeatability with the right “low shock”,
ramped on/off switching times) can be adjusted by
• Fully short-circuit and or “proportional” features.
times through the use of an in-built potentiometer.
an integral amplifier. reverse-polarity protected
An adjustment also allows
The switching time range for compensation of any • Protection to IP67
is 50 ms to 5 seconds. deadband in the valve.

Electrical Block Diagram Power


input
EHH-AMP-702-C-2* 1
24V DC + Dither X1
10 Series
0V –
2 Max. Power Solenoid
Gain limiter PWM amp.
2k7W X2
Ramp
3
Command Deadband
Signal 4
(NC)

Note
This product has been designed and tested to meet spe-
cific standards outlined in the European Electro-magnetic
Compatibility Directive (EMC) 89/336/EEC, amended by
91/26/EEC, 92/31/EEC and 93/68/EEC, article 5. For
instructions on installation requirements to achieve effec-
tive protection levels, see this leaflet and the Installation
Wiring Practices for Vickers Electronic Products leaflet
2468. Wiring practices relevant to this Directive are indicat-
ed by a warning symbol and Electromagnetic Compatibility
(EMC).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-21


Model Code/
Operating Data

EHH – AMP – 702 – C – 2* 1 Design number, 20 series


Subject to change. Installation
dimensions unaltered for
1 design numbers 20 to 29
inclusives.

OPERATING DATA
Electrical
Connections
1 24V DC
2 OV (power and signal)
3 Positive command signal
4 Negative command signal
Power (input) supply 20-30V DC including ± 10% maximum ripple
ripple (peak-to-peak)
24V DC nominal
Absolute maximum voltage 40V
Max. power consumption 35W
including solenoid
Reverse polarity protected Yes
Short circuit protected Yes
Maximum output current 1,6A
Maximum output voltage typical Typically 1,5V below supply voltage
(1,6A output current)
Command signal
For output (LED on) 15V to 24V
For no output (LED off) 0V to 5V
Input impedance 2700 ohms
Deadband adjustment range <100 - 1000 mA
Gain adjustment range 0.02A to 1,6A (maximum)
Dither adjustment range 0 to 500 mA
Ramp time 50 ms to 5s
PWM frequency 1200 Hz ± 10%
Dither frequency 120 Hz ± 10%
Protection IEC 529: IP67 (when correctly installed with interface seal in place)
Fully short-circuit and reverse-polarity protected
Isolation to VDE 0110 Group “B”
Electromagnetic compatibility (EMC):
Emission EN 50081-2
Immunity EN 50082-2

Mechanical
Housing PA6 glass-reinforced plastic (conforming to UL-94HB). Color: gray
Mounting interface ISO 4400 (DIN 43650)
Cable clamp Pg9 screw type
Cable diameter Ø 5 to 10 mm (0.197 to 0.394” dia.)
Wire section 0,5 to 1,0 mm2 (20-17 AWG)
Temperature, ambient range -20° to +70°C (-4° to +158°F)
Mass 0,07 kg (0.154 lb)

C-22 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Installation Data

Input/Output Command
Characteristics signal C
Functions
Switch-on/off: after switch-
ing on with a 15V signal the
amplifier will remain in the 24V,
“on” condition with a com- typical
mand signal above 6V. The
command signal must be
reduced to below 5V to Time
achieve switch-off of the
amplifier. Output Ramp time
current

Gain
adjustment

Deadband compensation
Time

Installation Dimensions
mm (inch)

88 (3.52) 3rd angle


22 projection
(0.87)

39 Solenoid Connections
(1.54)
No connection
1 (or 2)

34
(1.34)
2

2 (or 1)
38
(1.5)
1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-23


Installation Data

Adjustments Gain Deadband


Ramp Dither
Ramp time: Turn clockwise Terminal 1: Power Supply
to increase ramp time. 20V-30V DC, positive.
Gain: Turn clockwise to Terminal 2: Power Supply
increase gain. 0V.
Deadband compensation: Terminal 3: Switch com-
Turn clockwise to increase mand signal positive.
deadband compensation Terminal 4: Not connected
current.
LED
Dither: Turn clockwise to
increase the dither current.

4 3 2 1

P
Installation Wiring
4 3 2 1

24V
0V
>15V

Protective ground connection

WARNING
Electromagnetic
• Compatibility
(EMC) - Screened cables
should be used and particu-
lar attention paid to the
grounding of the screens as
shown in the above diagram.

C-24 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Installation Data

Assembly Showing
Wiring Connection C
Points

WARNING
Ensure cable
• clamp nut is ade-
* quately tightened to secure
cable. Do not connect, or
disconnect, the plug while
power is on. Do not mount,
or dismount, the plug while
power is on.

Wiring Preparation
4 x 0.5-1.0 mm 2
(20 AWG-17 AWG)

5 (0.2)
Ø 5-10 (0.197-0.394 dia)

40 (1.6)

*All seals must be fitted correctly at plug installation to provide protection to IP67 (IEC 529).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 C-25


Installation Data

Start-Up Procedure • Switch off power supply Spare Parts


• Correctly wire the plug and command/input sig- The only spare part avail-
and, before mounting it nal and then install plug able is the interface seal,
on the valve solenoid, on solenoid. Ensure that part number 732100.
apply 24V DC (20 to 30V all seals are fitted cor-
limits) to the “power rectly and clamped as Ordering Procedure
input” terminals. the retaining screw is
tightened: this is essen- Order plug by full model
• Check for correct plug tial in providing IP67 code, and spare interface
function by illumination/ protection. seals by part number
non-illumination of the 732100.
LED: • Ensure that the hydraulic
system will not cause
a. Apply less than 2 to 3 any erratic movement of
volts to the input termi- actuators, then:
nal: LED should not be
illuminated. – Switch on power
supply again.
b. Increase voltage: the
LED should illuminate – Repeat LED/function
when the voltage reach- check as in 2.
es 15V. Do not exceed An LED malfunction now
30V command signal. indicates a short circuit at
c. Decrease voltage: the the load.
LED should go off when • Successful completion of
the voltage is less than these checks means that
5V. the plug and load are
ready for use.

C-26 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


MRV3-10
Manual rotary valve

2 3

1
Description Operation
The MRV3-10 is a 3-way, This valve will direct flow the operator 90°, flow cross-over transition, all
2 or 3 position, manual between ports 1 and 3 will be directed between ports are blocked.
semi-rotary directional and block port 2 in one ports 1 and 2 and port 3
screw-in cartridge valve. position, and by turning will be blocked. During
2 3

Functional Symbol RATINGS AND SPECIFICATIONS


2 3 1
MRV3-10(V)-D/E Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 position models
2 3 Typical application pressure (all ports) 210 bar (3000 psi)
2
1 3 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
1 Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
1 Temperature range -40° to 120°C (-40° to 248°F)
MRV3-10(V)-D2/E2 Manual operators D - Lever (3-position detent)*
2 position models2 3 D2 - Lever (2-position detent)*
E - Ball (3-position detent)*
2 3 E2 - Ball (2-position detent)*
2 3 * Light duty housing only. K - Knob (2-position, no detent)
1
Cavity C-10-3
1 Fluids All general purpose hydraulic fluids such as:
1 MIL-H-5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
3 Standard housing materials Aluminum
Weight cartridge only 0,22 kg (0.48 lbs)
Seal kit 565804 (Buna-N)
2 889599 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curve 0 10 20
Cartridge only 80 6
3
Pressure Drop - bar
Pressure Drop - psi

3 60
2 3 4

2 40
2
1
2
20
1 Flow - L/min (21,8 cSt oil @ 49°C)
1
0 10 (21,8 cSt oil @ 49°C)20
Flow - L/min
80 0 6 0
00 Flow - L/min (21,8 cSt oil @ 49°C) 20
2 10 4 6
80 0 10 20 6
Pressure Drop - bar
Pressure Drop - psi

60 80 Flow - USgpm (105 SUS oil @ 120°F) 6


4
- bar
- psi- psi

60
- bar

40 60 4
Drop
Drop

4
Drop
Drop

40
2
Pressure
Pressure

20 40
Pressure
Pressure

2
D-4 20
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
2
0 20 0
Model Code MRV3-10

MRV3 – 10 (V) – ** – **– 00

1 2 3 4 5 6

D
1
Function 4Manual operators 5 Port size
MRV3 - Manual rotary valve O - No operator O - Cartridge only
D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
2 Size D2 - Lever (2-position Aluminum Aluminum
10 - 10 Size detent)* Light duty Fatigue rated
E - Ball (3-position 3B 3/8” BSPP 02-173358 –
3 Seals detent)* 6T SAE 6 566162 –
Blank - Buna-N E2 - Ball (2-position
2G 1/4” BSPP – 876705
V - Viton® detent)*
K - Knob (2-position, 3G 3/8” BSPP – 876714
no detent) 6H SAE 6 – 876704
*Light duty housing only. 8H SAE 8 – 876711
See section J for housing details.

6 Special features

Dimensions 00 - None SS - 316 Stainless Steel


mm (inch) (Only required if valve has external components (only
MRV3-**(V)-D(2) special features, omitted available for “O” and “K”
Torque cartridge in Port 3 to 1 if “00”) options)
aluminum housing Port 3 to 1 Po
45°
47-54 Nm (35-40 ft. lbs) 45°
Arrow can be re-located
Arrow
by can be the
slackening re-located
domed 41,0 Arrow can(Vbe re-located
by slackening 41,0 M RV3-* * )-Kthe 41,0
nut and turningthe
thedomed
plate. (1.61)
(1.61) by slackening domed
nut and turning
Re-tighten nut. the plate. Mid
Arrow can be relocated
nutdomed
and turning thebyplate.
Locating slackening
pin hole, (1.61)
Re-tighten nut. 45° Mid the Locating
nutfour
and turningpin
thehole,
optional plate.
slots
45° position Re-tighten nut.
Re-tighten nut.four optional slots
42,0 Port 1 to 2 position in detent plate
42,0 Port 1 to 2 (not for in detent plate Port 1 to
(1.65) 83,0 (not for
2-position 17,1 ?± 0.0542,0
(1.65) Locating Pin 83,0 2-position 17,1 ?± 0.05
(3.27) models) (1.65)
(0.672 ± 0.002)
90° Installation 9,5 (0.37) (3.27) models) (0.672 ± 0.002)
90° 9,5 (0.37) 9,5 (0.37)
90°
Mid Locating pin hole, 58,0
four optional slots 58,0 58,0
position (2.28)
(not for in detent plate (2.28) (2.28)
2-position 17,1 ?± 0.05 This hole omitted
This hole
from omitted
detent plate of
models) (0.672 ± 0.002) Locating pin from detent plate of
Locating pin MRV3-10(V)-D2/E2 Locating
9,5 (0.37) MRV3-10(V)-D2/E2
9,5 (0.37) 9,5 (0.37)
MRV3-**(V)-E(2) Ø 3,45/3,50
37,0 Ø 3,45/3,50
(#29 or 0.136)
37,0 37,0 (#29xor 0.136)
(1.45) 25,4 (1.0) hex drill 4,8
(1.45) 25,4 (1.0) hex (1.45) (0.187)4,8
drill x deep 25,4 (1.0) hex
This hole omitted (0.187) deep
from detent plate of in mating housing
in mating housing
MRV3-10(V)-D2/E2
0.875" -14 T hd.
46,0 0.875" -14 T hd. 42,0 0.875" -14 T hd.
46,0 3
Ø 3,45/3,50 42,0
(1.81) 3 (1.65) 46,0 3
(1.81) (#29 or 0.136) (1.65)
2
drill x 4,8 (1.81)
2
(0.187) deep 2
in mating housing 41,0 38,1
1 41,0 38,1
1 (1.61) (1.50) 41,0
Ø 15,80 (0.622) (1.61) (1.50) 1
Ø 15,80 (0.622) Ø 15,80 (0.622) (1.61)
Ø 17,40 (0.685)
Ø 17,40 (0.685) Ø 17,40 (0.685)
Ø 25,4 (1.0)
Ø 25,4 (1.0)
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-5
MRV3-16
Manual rotary valve

2 3

Description Operation
The MRV3-16 is 2a 3-way,
3 This valve will direct flow operator 90°, flow will cross-over transition, all
2 or 3 position, manual between ports 1 and 3 be directed between ports are blocked.
semi-rotary directional and block port 2 in one ports 1 and 2 and port 3
screw-in cartridge valve. position. By turning the will be blocked. During
1

Functional Symbol RATINGS AND SPECIFICATIONS


MRV3-16(V)-D Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 position models
Typical application pressure (all ports) 210 bar (3000 psi)
222 333 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 64 L/min (17 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
111 Temperature range -40° to 120°C (-40° to 248°F)
MRV3-16(V)-D2 Manual operators D - Lever (3-position detent)*
2 position models D2 - Lever (2-position detent)*
*Light duty housing only. K - Knob (2-position, no detent)
222 333 Cavity C-16-3
3 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
111 Filtration Cleanliness code 18/16/13
2 Standard housing materials Aluminum
Sectional View
Weight cartridge only 0,53 kg (1.16 lbs)
Seal kit 889632 (Buna-N)
1 889636 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curve 0 10 20 30 40 50 60
Cartridge only 80 6
Pressure Drop - psi

60 Pressure Drop - bar


333 4
40
222
2
20

111 0 0
0 2 4 6 8 10 12 14 16
Flow - USgpm (105 SUS oil @ 120°F)

Flow- --L/min
Flow
Flow L/min(21,8
L/min (21,8cSt
(21,8 cStoil
cSt oil@@
oil @49°C)
49°C)
49°C)
000 10
10
10 20 20
20 30
30
30 40
40
40 50
50
50 60
60
60
80
80 666
psi

80
Drop - psi
Pressure Drop- -psi

bar
Drop - bar
Pressure Drop- -bar

60
PressureDrop

60
60 444
PressureDrop
Pressure

40
40
40
Pressure

222
D-6 20
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4
20 September, 2007
20
Model Code MRV3-16

MRV3 – 16 (V) – ** – ***– 00

1 2 3 4 5 6

D
1Function 4 Manual operators 5 Port size
MRV3 - Manual rotary valve O - No operator O - Cartridge only
D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
2 Size D2 - Lever (2-position Aluminum Aluminum
16 - 16 Size detent)* Light duty Fatigue rated
K - Knob (2-position, 12T SAE 12 566152 –
no detent) 6B 3/4” BSPP 02-175465 –
3 Seals *Light duty housing only
10H SAE 10 – 876721
Blank - Buna-N 12H SAE 12 – 876723
V - Viton®
4G 1/2” BSPP – 876720
8G 3/4” BSPP – 876722
See section J for housing details..

6 Special features

00 - None
Dimensions (Only required if valve has
Arrow can be relocated by special features, omitted
mm (inch) MRVthe 3 -**domed
(V)relocated
-K nut by
slackening
Arrow can be if “00”)
Torque cartridge in and turning thebethe
slackening
Arrow can plate.domed
relocated nut
by slackening
the turning
Re-tighten
and domed
nut.nuttheandplate.
turning the plate.
aluminum housing Re-tighten nut.
Re-tighten nut.
108-122 Nm (80-90 ft. lbs) 61,0
(2.40)61,0 MRV3-**(V)-D(2)
Lo
(2.40) fo
90° Port 3 to 1
Port 3 to 1 45° in
90°
Locating Pin 45° 24,9 ± 0.05
Installation 58,0 (0.9824,9 ±0
± 0.00
(2.28)58,0 (0.98 ±
Locating pin hole, (2.28)
four optional slots 45°
in detent plate Port 1 to 2 45° Mid position
11,1 (0.43) (not Mid
for position
24,9 ± 0.05 11,1 (0.43) Port 1 to 2 105 (4 .13) 2-position
(not for
(0.98 ± 0.002) 11,0 (0.438) 105 (4 .13) models)
2-position
53,0 Ø
11,0 (0.438) models) (#
(2.08)53,0
(2.08) d
position 38,1 (1.0. 50) hex 76,0 (0
for 38,1 (1.0. 50) hex (3.0) 76,0 in
sition (3.0) Locating pin
els) 1.3125 " -12 Th d. Locating pin
Ø 3,45 3,50
(#29 or 0.136) 73,0 3 1.3125 " -12 Th d.
drill x 4,8 (2.87)73,0 3
(0.187) deep (2.87) 2
in mating housing 2
pin
1
1 Ø 26,95 (1.061)
Ø 26,95
Ø 28,55 (1.061)
(1.124)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-7


MRV4-10
Manual rotary valve

4 2

3 1
Description Operation
The MRV4-10 is a 4-way, This valve will direct flow operator 90°, flow will be transition, ports 2 and 4
2 or 3 position,
4 manual
2 between ports 1 and 2 directed between ports are blocked and ports
semi-rotary directional and ports 3 and 4 in one 1 and 4 and port 3 to port 1 and 3 are connected.
screw-in cartridge valve. position. By turning the 2. During the cross-over

Functional Sy3mbol 1 RATINGS AND SPECIFICATIONS


3 position models Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
4 2
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 11 L/min (3 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
3 1 Manual operators D - Lever (3-position detent)*
D2 - Lever (2-position detent)*
Sectional View E - Ball (3-position detent)*
E2 - Ball (2-position detent)*
* Light duty housing only. K - Knob (2-position, no detent)
Cavity C-10-4
4 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
3 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,17 kg (0.38 lbs)
2
Seal kit 565805 (Buna-N)
889600 (Viton®)
Viton is a registered trademark of E.I. DuPont
1 4

3
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curves
2 0 5 10
Cartridge only 150 10
A
14
Pressure Drop - bar

8
Pressure Drop - psi

100
3 6
A - Port 3 to 4
or 3 to 2 Flow - L/min (21,8 cSt oil @ 49°C)
B
2 B - Port 4 to 1 0 5 10 4
50150 10
or 2 to 1
A 2
1
Pressure Drop - bar

8
Pressure Drop - psi

0100 0
1 0 2 3 6
Flow - L/min (21,8 cSt oil @ 49°C)
Flow - USgpm (105 SUS oil @ 120°F) B
0 5 10 4
150 50 10
A
2
sure Drop - bar

8
sure Drop - psi

100
0 0
6
D-8 0
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 1 2 3
B
Flow - USgpm (105 SUS oil @ 120°F)
4
Model Code MRV4-10

MRV4 – 10 (V) – ** – **– 00

1 2 3 4 5 6

D
1Function 4 Manual operators 5 Port size
MRV4 - Manual rotary valve O - No operator O - Cartridge only
4 way D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
D2 - Lever (2-position Aluminum Aluminum
2 Size detent)* Light duty Fatigue rated
10 - 10 Size E - Ball (3-position 3B 3/8” BSPP 02-179705 –
detent)* 6T SAE 6 566161 –
E2 - Ball (2-position
2G 1/4” BSPP – 876709
3 Seals detent)*
K - Knob (2-position, 3G 3/8” BSPP – 876715
Blank - Buna-N
no detent) 6H SAE 6 – 876708
V - Viton®
*Light duty housing only. 8H SAE 8 – 876713
See section J for housing details.

Dimensions 6 Special features


mm (inch) 00 - None SS - 316 Stainless Steel
Torque cartridge in MRV4-**(V)-D(2) (Only required if valve has external components (only
aluminum housing Port 3 to 4 special features, omitted available for “O” and “K”
Port
and 2 t3o to
14 if “00”) options) P
47-54 Nm (35-40 ft. lbs) and 2 t o 1
45° a
45°
Arrow can be relocated 41,0 MRV4-**(V)-K
by Arrow can be
slackening therelocated
domed 41,0
(1.61)
nutbyand
slackening theplate.
turning the domed Arrow can be relocated 41,0
(1.61) by slackening
Locatingthepin
domed
hole,
nut and turning
Re-tighten nut. the plate.
nut and Locating
turning the pin
plate.hole,
(1.61)
Re-tighten nut. 45° Mid four optional slots
Port 3 to 2 45° Mid
position Re-tighten nut.
four optional slots
Port 3 to in detent plate
90°
90° Locating Pin and 4 to 12 83
position
17,1 ± 0.05
in detent plate Port 3 t
and 4 to 1 83 17,1 ?±± 0.05 90°
42.0 (3.27) (0.672 0.002) and 4 to
42.0 Installation 9,5 (0.375) (3.27) (0.672?± 0.002)
(1.65) 9,5 (0.375) 42.0
(1.65) 9,5 (0.375)
Locating pin hole, (1.65)
Mid four optional slots 58,0
position in detent plate 58,0
(2.28) 58,0
17,1 ± 0.05 9,5 (0.38) (2.28)
(2.28)
37,0 (0.672?± 0.002) 9,5 (0.38) 9,5 (0.38)
37,0 Locating pin Ø 3,45/3,50
(1.46) Locating pin 37Ø,03,45/3,50
(#29 or 0.136)
(1.46) (#29 or 0.136) Locating
25,4 (1.0) h ex (1.46)
drill x 4,8
25,4 (1.0) h ex
MRV4-**(V)-E(2) (0.187)x deep
drill 4,8
0.875"-14 Thd.? in (0.187)
mating deep
housing 25,4 (1.0) h ex
0.875"-14 Thd.? in mating housing
4 0.875"-14 Thd.?
4 3,45/3,50
Ø
61,9 4
3 (#29 or 0.136)
61,9
(2.44) 3 x 4,8
drill 61,9 3
(2.44) (0.187) deep
2 (2.44)
2 mating housing
in 42
42
(1.65) 2
1 (1.65)
1 Ø 15,80 (0.622)
Ø 15,80 (0.622) 41,0 38,1 1
Ø 17,40 ( 0.685) 41,0
(1.61) 38,1
(1.50) Ø 15,80 (0.622)
Ø 17,40 ( 0.685) 41,0
(1.61) (1.50)
Ø 18,97 (0.747) Ø 17,40 ( 0.685) (1.61)
Ø 18,97 (0.747)
Ø 25,4 (1. 0) Ø 18,97 (0.747)
Ø 25,4 (1. 0)

8,1 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-9
50)
MRV4-16
Manual rotary valve

4 2

3 1

Description Operation
The MRV4-16 is a 4-way, This valve will direct flow operator 90°, flow will be transition, ports 2 and 4
4 2
2 or 3 position, manual between ports 1 and 2 directed between ports are blocked and ports
semi-rotary directional and ports 3 and 4 in one 1 and 4 and ports 3 and 2. 1 and 3 are open to each
screw-in cartridge valve. position. By turning the During the cross-over other.

3 1
Functional Symbol RATINGS AND SPECIFICATIONS
3 position models Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
3 1
Manual operators D - Lever (3-position detent)*
D2 - Lever (2-position detent)*
Sectional View * Light duty housing only. K - Knob (2-position, no detent)
Cavity C-16-4
4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
3 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
2 Weight cartridge only 0,65 kg (1.43 lbs)
Seal kit 889634 (Buna-N)
889638 (Viton®)
Viton is a registered trademark of E.I. DuPont
1

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


3 Curves 0 5 10 15 20 30 40 50
Cartridge only 150 10
Pressure Drop - bar
Pressure Drop - psi

2
8
100
1 4 A 6
A - Port 3 to 4
or 3 to 2 50 4
3
B - Port 4 to 1 Flow - L/min (21,8 cSt oil @ 49°C) B 2
or 2 to 1
2 0 5 10 15 20 30 40 50
0 0
150 10
0 1 2 3 4 5 10
Pressure Drop - bar
Pressure Drop - psi

1 Flow - USgpm (105 SUS oil @ 120°F) 8


100
A 6

Flow - L/min (21,8 cSt oil @ 49°C) 4 10


50
0 5 10 15 20 30 40 50
B 2
150 10
essure Drop - bar
essure Drop - psi

0 0
0 1 2 3 4 5 10 8
100
Flow - USgpm (105 SUS oil @ 120°F)A 6
D-10 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007

50 4
Model Code MRV4-16

MRV4 – 16 (V) – ** – ***– 00

1 2 3 4 5 6

1 Function 4 Manual operators 5 Port size

MRV4 - Manual rotary valve, O - No operator O - Cartridge only D


4 way D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
2 D2 - Lever (2-position Aluminum Aluminum
Size
detent)* Light duty Fatigue rated
16 - 16 Size K - Knob (2-position, 12T SAE 12 566411 –
no detent) 6B 3/4” BSPP 02-175468 –
3Seals *Light duty housing only.
10H SAE 10 – 876729
Blank - Buna-N 12H SAE 12 – 876731
V - Viton® 4G 1/2” BSPP – 876728
6G 3/4” BSPP – 876730
See section J for housing details.

6 Special features
Dimensions
mm (inch)
00 - None
(Only required if valve has
Torque cartridge in MRV4-**(V)-D(2) special features, omitted
aluminum housing Port Port
3 to 34 to
and 2 to 21 to 1
4 and if “00”)
Port 3 to 4 and
108-122 Nm (80-90 ft. lbs) 45° 45°
Arrow can be relocated
Arrow can
by slackening thebedomed
relocated
by turning
slackening 58,058,0 Arrow can be relocated
nut and the the domed
plate. by slackening the domed 58,0
nut and
Re-tighten nut.turning the plate. (2.28)
(2.28) nut and turning the plate.
Re-tighten nut. Locating
Re-tighten nut. pin hole,
Locating pin hole, (2.28)
45° 45° Mid Mid fourfour
optional slotsslots
optional
position in detent plateplate
in detent
PortPort
3 to 32 to 2 position
and and
4 to41to 1 105,0 Port 3 to
1,061,0 105,0 24.924.9
?± 0.05
?± 0.05
Lo90°
catin90°
g Pin (4.13) 61,0 and 4 to
2.4)(2.4) 11,111,1
(0.438) (4.13) (0.980 ?± 0.002)
(0.980 90°
Installation (0.438) (2.4) ?± 0.002) 11,1 (0.438)

Locating pin hole,


four optional slots 77,0 77,0
Mid (3.03) 77,0
position in detent plate (3.03)
11,111,1
(0.438) (3.03)
(0.438) 11,1 (0.438)
53,053,0 24.9?± 0.05
Ø 3,45/3,50
Ø 3,45/3,50
.09) (0.980?± 0.002) Locating pin pin 53,0(#29 or 0.136)
(2.09) Locating
(2.09)drill (#29 or 0.136)
x 4,8x 4,8 Locating pin
drill
38,138,1
(1.5)(1.5)
h ex h ex MRMRV4-**(V)-E(2)
V4-**(V)-E(2)
MRV4-**(V)-E(2) (0.187) deep
(0.187) deep
in mating housing
in mating 38,1 (1.5) h ex
housing MRV4-**
1.312"-12 Thd.Thd.
1.312"-12 1.312"-12 Thd.
4 4
101,6101,6 Ø 3,45/3,50 4
(4.0)(4.0) (#29 or 0.136) 101,6
3 drill
3 x 4,8 42 42 (4.0)
(0.187) deep 3
(1.65)
(1.65)
2 in2mating housing
2
1 1 41,041,0 38,138,1
Ø 25,37 (0.999)
Ø 25,37 (0.999) (1.50) 1 41,0
Ø 26,95 (1.061) (1.61)
(1.61) (1.50) Ø 25,37 (0.999)
Ø 26,95 (1.061) Ø 26,95 (1.061) (1.61)
Ø 28,55 (1.124)
Ø 28,55 (1.124) Ø 28,55 (1.124)
Ø 25,4 (1. 0)(1. 0)
Ø 25,4

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-11


MRV5-10
Manual rotary valve

4 2

3 1

Description Operation
The MRV5-10 is a 4-way, This valve will direct flow operator 90°, flow will be
3 position, manual semi- between ports 1 and 2 directed between ports
MRV5-16
rotary directional screw-in and ports 3 and 4 in one 1 and 4 and port 3 to 2. Manual rotary valve
cartridge4valve. 2 position. By turning the During the cross-over

Functional Symbol RATINGS AND SPECIFICATIONS


3
3 position models 1 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
4 2
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 11 L/min (3 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
3 1 Temperature range -40° to 120°C (-40° to 248°F)
Manual operators D - Lever (3-position detent)*
Sectional View E - Ball (3-position detent)*
* Light duty housing only.
4
Cavity C-10-4 (see page 60)
Fluids All general purpose hydraulic fluids such as:
3 MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2 Standard housing materials Aluminum
Weight cartridge only 0,27 kg (0.59 lbs)
Seal kit 889625 (Buna-N)
1 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont

4 Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curves 0 2 4 6 8 10
3 Sectional View
Cartridge only 12
150
A 10
Pressure Drop - bar
Pressure Drop - psi

2
4 8
100
1 A - Port 3 to 4 6
3 or 3 to 2 B
50 4
B - Port 4 to 1
2 C
C - Port 2 to 1 2
Flow - L/min (21,8 cSt oil @ 49°C)
0 0 2 4 6 8 10 0
1
0 0.5 1 1.5 2 2.5 12 3
150 Flow - USgpm (105 SUS oil @ 120°F)A 10
Drop - bar
Drop - psi

Flow - L/min (21,8 cSt oil @ 49°C) 8


100
0 2 4 6 8 10 12
6
ssure Drop - Pressure

ssure Drop - Pressure

B 12
50
150 4
A 10
bar
psi

C
2
8
100 0
0
6
D-12 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4
0 September,12007
0.5 1.5 2 2.5 B 3
50 4
Flow - USgpm (105 SUS oil @ 120°F)
MR V5-10
Model Code MRV5-10

Model Code M

Model Code

MRV5 – 10 (V) – ** – **– 00

1 2 3 4 5 6

1 Function 4 Manual operators 5 Port size


MRV5 - Manual rotary valve, O - No operator O - Cartridge only
4 way D - Lever (3-position D
detent)* CODE PORT SIZE HOUSING NUMBER
E - Ball (3-position Aluminum Aluminum
2 Size Light duty Fatigue rated
detent)*
10 - 10 Size D2 - Lever (2-position 3B 3/8” BSPP 02-179705 –
detent) 6T SAE 6 566161 –
E2 - Ball (2-position detent) 2G 1/4” BSPP – 876709
3 Seals *Light duty housing only.
3G 3/8” BSPP – 876715
Blank - Buna-N
6H SAE 6 – 876708
V - Viton®
8H SAE 8 – 876713
See section J for housing details.

6 Special features

00 - None SS - 316 Stainless Steel


(Only required if valve has external components (only
special features, omitted available for “O” options)
if “00”)
Dimensions
mm (inch) MRV5-**(V)-D
Port 3 to 4
Torque cartridge in Arrow can be
relocated by and 2 to 1
aluminum housing slackening the 45°
0 47-54 Nm (35-40 ft. lbs) domed nut and
) turning the plate Port 3 to 4 Mid position
Arrow can
Re-tighten nut.be
relocated by 41,0 and 2 to 1 MRV5-**(V)-E
slackening the (1.61) 45°
domed nut and
Locating Pin
turning the plate
45° Mid position
Re-tighten nut. 41,0
Installation
38,1 Port(1.61)
3 to 2 42,0
(1.5) and 4 to 1 83,0
Locating pin hole, (1.65)
four optional slots (3.27) 45°
in detent plate 9,5 (0.375)
Port 3 to 2 42,0
17,1 ± 0.05 and 4 to 1 83,0
(0.672 ± 0.002) (3.27) (1.65)
9,5 (0.375)
58,0 41,0 38,1
(2.28) (1.6) (1.5) Lo
Locating pin fou
58,0 41,0 in
38,1
0.875" -14 Thd . (2.28) (1.6) Ø 25,4 (1. 0) (1.5) 17,1 ± 0.05 L
25,4 (1.0) hex (0.672 ± 0.00
Ø 3,45 3,50 4 Locating pin fo
(#29 or 0.136) in
drill x 4,8 (0.187) deep 0.875" -14 Thd61,9
. 3
Ø 25,4 (1. 0) 17,1 ± 0.05
in mating housing (2.43) 25,4 (1.0) hex
4 (0.672 ± 0.0
61,9 2
(2.43) 3
1 Ø 3,
Ø 15,75 (0.620) (#29
2
13 Ø 17,40 ( 0.685) drill x
Ø 18,97 (0.747) inØm3
1 Ø 15,75 (0.620) (#2
Ø 17,40 ( 0.685) dril
Ø 18,97 (0.747) in m

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-13


MRV5-16
Manual rotary valve

4 2

3 1

Description Operation
The MRV5-16 is a 4-way, This valve will direct flow operator 90°, flow will be transition, all ports are
3 position, manual semi- between ports 1 and 2 directed between ports blocked.
rotary directional screw-in and ports 3 and 4 in one 1 and 4 and ports 3 and 2.
cartridge 4valve. 2 position and by turning the During the cross-over

Functional Symbol RATINGS AND SPECIFICATIONS


3 position models
3
1 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
4 2
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
3 1 Temperature range -40° to 120°C (-40° to 248°F)
Manual operators D - Lever (3-position detent)*
4 * Light duty housing only.
Sectional View
Cavity C-16-4
3 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,65 kg (1.43 lbs)
1 Seal kit 889634 (Buna-N)
889638 (Viton®)
Viton is a registered trademark of E.I. DuPont

4 Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curves 0 10 20 30 40
3 Cartridge only
150 10

Pressure Drop - bar


Pressure Drop - psi

2 8
4
100
6
A - Port 3 to 4
1 3 or 3 to 2 A
4
B - Port 4 to 1 50
2 or 2 to 1 2
B
0 Flow - L/min (21,8 cSt oil @ 49°C) 0
1 0 0 10 2.5 20 5 30 7.5 4010 12
Flow - USgpm (105 SUS oil @ 120°F)
150 10
Drop - bar
Drop - psi

Flow - L/min (21,8 cSt oil @ 49°C) 8


100 14
0 10 20 30 40 6
A
ssure Drop -Pressure

ssure Drop -Pressure

150 104
50
bar
psi

82
B
100
0 60
D-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A
0 2.5 5 7.5 10 12 4
50
Model Code MRV5-16

MRV5 – 16 (V) – * – ***– 00

1 2 3 4 5 6

D
1 Function 3 Seals 5 Port size
MRV5 - Manual rotary valve Blank - Buna-N O - Cartridge only
4 way V - Viton®
CODE PORT SIZE HOUSING NUMBER
2 4 Aluminum Aluminum
Size Manual operators Light duty Fatigue rated
16 - 16 Size O - No operator 12T SAE 12 566411 –
D - Lever (3-position
detent)* 6B 3/4” BSPP 02-175468 –
*Light duty housing only. 10H SAE 10 – 876729
12H SAE 12 – 876731
4G 1/2” BSPP – 876728
6G 3/4” BSPP – 876730
See section J for housing details.

6 Special features
Dimensions 00 - None
mm (inch) Port (Only required if valve has
Port 3
3 to
to 4
4 and 2 to
and 2 to 1
1
special features, omitted
Torque cartridge in Arrow
Arrow can
can be
be
relocated
relocated by
by if “00”)
aluminum housing slackening
slackening the
the
45°
45°
108-122 Nm (80-90 ft. lbs) domed
domed nut
nut and
and
turning
turning the
the plate
plate
Mid position
Mid position
Re-tighten
Re-tighten nut.
nut. 58,0
58,0
(2.28)
(2.28)
Locating Pin
45°
45°
Installation
Port
Port 3
3 to
to 2
2
Locating pin hole, 105
105
and
and 44 to
to 1
1
four optional slots (4.13)
(4.13)
in detent plate
11,1
11,1 (0.43)
(0.43)

24,9 ± 0.05
(0.980 ± 0.002) 77
77,0
,0 Locating pin
pin hole
hole
(3.03) Locating
(3.03) four optional slot
four optional slot
in detent
in detent plate
plate
Locating pin
Locating pin
1.312"-12
1.312"-12 Thd.
Thd.
38,1 (1.5)
(1.5) hh ex
ex 24,9 ±
24,9 ±0.05
0.05
4 38,1 (0.980 ±
±0.002)
0.002)
Ø 3,45/3,50 4 (0.980
101,6
101,6
(#29 or 0.136) (4.0)
drill x 4,8 (4.0) 3
3
(0.187) deep
in mating housing
2
2

ØØ 3,45/3,50
3,45/3,5
1
1 (#29 or 0.13
0.1
Ø 25,37
Ø 25,37 (0.999)
(0.999) (#29 or
drill xx 4,8
drill 4,8
Ø 26,95 (1.061)
Ø 26,95 (1.061) (0.187) deedee
15 (0.187)
Ø 28,55
28,55 (1.124)
(1.124) in mating
in mating hh
Ø
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-15
MRV6-10
Manual rotary valve

4 2

3 1

Description Operation
The MRV6-10 is a 4-way, This valve will direct flow operator 90°, flow will be transition all ports 1, 3 and
3 position, manual semi- between ports 1 and 2 directed between ports 4 are open to each other
rotary directional screw-in and ports 3 and 4 in one 1 and 4 and port 3 to 2. and port 2 is blocked.
cartridge valve. position. By turning the During the cross-over
4 2

Functional Symbol RATINGS AND SPECIFICATIONS


3 position valves Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 1 Typical application pressure (all ports) 210 bar (3000 psi)
4 2
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 11 L/min (3 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
3 1 Temperature range -40° to 120°C (-40° to 248°F)
Manual operators D - Lever (3-position detent)*
E - Ball (3-position detent)*
Sectional View * Light duty housing only.
4
Cavity C-10-4
3 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2 Standard housing materials Aluminum
Weight cartridge only 0,27 kg (0.59 lbs)
Seal kit 889625 (Buna-N)
1 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont

4
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curves
3 0 2 4 6 8 10
Cartridge only 12
150
4 2 A 10
Pressure Drop - bar
Pressure Drop - psi

8
3 100
A - Port 3 to 4
1 or 3 to 2 6
B
2 B - Port 4 to 1 4
50
C - Port 2 to 1 C 2
Flow - L/min (21,8 cSt oil @ 49°C)
1 0
0 0 2 4 6 8 10
0 0.5 1 2.5 2 2.5 12 3
150 Flow - USgpm (105 SUS oil @ 120°F)
A 10
Flow - L/min (21,8 cSt oil @ 49°C)
Pressure Drop - bar
Pressure Drop - psi

0 2 4 6 8 10 8
100 12
6 16
150 B
A 10
4
ssure Drop - bar
essure Drop - psi

50
C 8
100 2
6
D-16 0
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B 0
0 0.5 1 2.5 2 2.5 34
50
Model Code MRV6-10

MRV6 – 10 (V) – * – **– 00

1 2 3 4 5 6

1Function 4 Manual operators 5 Port size


MRV6 - Manual rotary valve O - No operator O - Cartridge only D
D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
2 Size E - Ball (3-position Aluminum Aluminum
10 - 10 Size detent)* Light duty Fatigue rated
*Light duty housing only. 3B 3/8” BSPP 02-179705 –
6T SAE 6 566161 –
3 Seals 2G 1/4” BSPP – 876709
Blank - Buna-N 3G 3/8” BSPP – 876715
V - Viton®
6H SAE 6 – 876708
8H SAE 8 – 876713
See section J for housing details.

6 Special features

00 - None SS - 316 Stainless Steel


(Only required if valve has external components (only
Dimensions MRV6-**(V)-D special features, omitted available for “O” options)
mm (inch) Arrow can be relocated if “00”)
by slackening the domed
Torque cartridge in nut and turning the plate.
Re-tighten nut.
aluminum housing Port 3 to 4
47-54 Nm (35-40 ft. lbs) and 2 to 1
0 Arrow can be relocated 45°
) by slackening the domed
nut and turning the plate. Mid position
Re-tighten nut. 41,0
Locating Pin (1.61) Port 3 to 4
and 2 to 1 MRV6-**(V)-E
Installation 45°
45°
38,1 Locating pin hole, Port 3 to 2 Mid position
(1.5) four optional slots and41,0
4 to 1 83,0 42,0
in detent plate (1.61) (3.27) (1.65)
9,5 (0.37)
45°
17,1 ± 0.05 Port 3 to 2
(0.672 ± 0.002) and58,0
4 to 1 83,0 42,0
(2.28)
9,5 (0.37) (3.27) 41,0 (1.65)
Locating pin 38,1
(1.6) (1.5)

0.875"-14 Thd. 58,0


25,4 (1.0) hex Ø 25,4 (1. 0)
(2.28) 41,0 17,1 ±
4 Locating pin 38,1
(1.6) (0.672
Ø 3,45 3,50 (1.5)
61,9
(#29 or 0.136)
drill x 4,8 (2.43) 3
0.875"-14 Thd.
(0.187) deep 25,4 (1.0) hex Ø 25,4 (1. 0) 17,1 ± 0
in mating housing
42 (0.672 ±
61,9 1
(2.43) 3 Ø 15,82 (0.623)
Ø 17,42 ( 0.686)
17
Ø 19,00 (0.748)
2
1
Ø 15,82 (0.623)
Ø 17,42
EATON Vickers Screw-In ( 0.686)
Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-17
Ø 19,00 (0.748)
MLV9-12-A
4 2
4-Way, 3-Position, screw-in cartridge manual lever valve
5 1 PTS9-16

CF EF
4 2

LS 5 1
PFRD-XX
Description Operation
The MLV9-12-A
3 P is a 4-way, In the center position, this In position 1, flow is direct- In position 2, flow is direct-
3-position, direct acting, valve allows flow from port ed from port 3 to port 2 ed from port 3 to port 4
spool CF
type directional
EF 3 to port 1 and blocks ports and from port 4 to port 1. and from port 2 to port 1.
control4valve.2 2 and 4.

LS 5 1
PFRS-XX

3 P
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
SV9-8A
Fatigue pressure 3,000 psi per NFPA/T2-6-1 R2-2000
3 1 Rated burst pressure (626 bar) 9090 psi per NFPA/T2-6-1 R2-2000
Max flow 60 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-4
2 4 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
SV9-8B
Filtration Cleanliness code 18/16/13
Sectional View
3 1
Housing material (standard) Aluminum
Weight .57 kg (1.25 lbs)
Seal Kit 9900171-000 (Buna-N), 9900172 (Viton)
Viton is a registered trademark of E.I. DuPont
Internal Leakage 246 cm3/min (15 in3/min) max. @ 210 bar (3000psi)
2 4
Endurance tested to 1 million cycles at full rated flow and pressure.
SV9-8E

3 1

Flow - L/min
19 38 60
400 28
4
2 4

300 21
Pressure Drop - psi

Pressure Drop - bar

SV9-8F
A
3 1
3 200 14
B

100 7
2
0
0 5 10 15
A - 3-2 Flow - USgpm
1 B - 4-1

D-32 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


MLV9-12-B
CF EF
4-Way,
4
3-Position, screw-in cartridge manual lever valve
2

LS 5 1
PFRD-XX

3 P

CF EF
4 2

LS 5 1
PFRS-XX
Description Operation
3 P
The MLV9-12-B is a 4-way, In the center position, all In position 1, flow is direct- In position 2, flow is direct-
3-position, direct acting, ports are open to each ed from port 3 to port 4 ed from port 3 to port 2
spool type directional other. and from port 2 to port 1. and from port 4 to port 1.
control2valve. 4
D
SV9-8A

3 1

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
SV9-8B
Fatigue pressure 3,000 psi per NFPA/T2-6-1 R2-2000
3 1 Rated burst pressure (626 bar) 9090 psi per NFPA/T2-6-1 R2-2000
Max flow 60 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-4
2 4 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration
SV9-8E Cleanliness code 18/16/13
Sectional View Housing material (standard) Aluminum
3 1
Weight .57 kg (1.25 lbs)
Seal Kit 9900171-000 (Buna-N), 9900172 (Viton)
Viton is a registered trademark of E.I. DuPont
Internal Leakage 246 cm3/min (15 in3/min) max. @ 210 bar (3000psi)
2 4
Endurance tested to 1 million cycles at full rated flow and pressure.
SV9-8F

3 1
Flow - L/min
19 38 60
400 28
4

300 21
Pressure Drop - psi

Pressure Drop - bar

A
3
200 14
B

100 7
2

0
1 0 5 10 15
A - 3-2 Flow - USgpm
B - 4-1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-33


3 P
MLV9-12-E
CF EF
4-Way,
4 3-Position,
2 screw-in cartridge manual lever valve

LS 5 1
PFRS-XX

3 P

2 4

SV9-8A

Description
3 1 Operation
The MLV9-12-E is a 4-way, In the center position, all In position 1, flow is direct- In position 2, flow is direct-
3-position, direct acting, ports are blocked. ed from port 3 to port 4 ed from port 3 to port 2
spool type directional and fromport 2 to port 1. and from port 4 to port 1.
control2 valve4.

SV9-8B

3 1

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
SV9-8E
Fatigue pressure 3,000 psi per NFPA/T2-6-1 R2-2000
3 1 Rated burst pressure 626 bar) 9090 psi per NFPA/T2-6-1 R2-2000
Max flow 60 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-4
2 4 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Sectional View Filtration
SV9-8F Cleanliness code 18/16/13
Housing material (standard) Aluminum
3 1
Weight .57 kg (1.25 lbs)
Seal Kit 9900171-000 (Buna-N), 9900172 (Viton)
Viton is a registered trademark of E.I. DuPont
Internal Leakage 246 cm3/min (15 in3/min) max. @ 210 bar (3000psi)
Endurance tested to 1 million cycles at full rated flow and pressure.

Flow - L/min
19 38 60
400 28

300 21
Pressure Drop - psi

Pressure Drop - bar

A
200 14
4
B

100 7
3

0
0 5 10 15
2
A - 3-2 Flow - USgpm
B - 4-1
1

D-34 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


3 P

MLV9-12-F
2 4
4-Way, 3-Position, screw-in cartridge manual lever valve
SV9-8A

3 1

2 4

SV9-8B

3 1
Description Operation
The MLV9-12-F is a 4-way, In the center position, port In position1, flow is direct- In position 2, flow is direct-
3-position, direct acting, 1, port 2, and port 4 are ed from port 3 to port 4 ed from port 3 to port 2
spool type directional con- open to each other while and from port 2 to port 1. and from port 4 to port 1.
trol valve.2 4 port 3 is blocked.
D
SV9-8E

3 1

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
SV9-8F
Fatigue pressure 3,000 psi per NFPA/T2-6-1 R2-2000
3 1 Rated burst pressure (626 bar) 9090 psi per NFPA/T2-6-1 R2-2000
Max flow 60 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Housing material (standard) Aluminum
Weight .57 kg (1.25 lbs)
Seal Kit 9900171-000 (Buna-N), 9900172 (Viton)
Viton is a registered trademark of E.I. DuPont
Internal Leakage 246 cm3/min (15 in3/min) max. @ 210 bar (3000psi)
Endurance tested to 1 million cycles at full rated flow and pressure.

Flow - L/min
19 38 60
400 28
4
300 21
Pressure Drop - psi

Pressure Drop - bar

3 200 A 14

B
100 7
2
0
0 5 10 15
A - 3-2 Flow - USgpm
1
B - 4-1

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-35


Model Code MLV9-12

2 4
MLV9 – 12 – * – * – * – L – * – *** – **

1 2 3 4 35 1 6 7 8 9

2 4
2 4 2 4

1 Function
4 Spool Center Condition 9 Lever Position
MLV9 - Manual Lever Valve 3
3 1
1
3 1 00 - 90°
A B 01 - 45°
2 Size
2 4 2 4 02 - 0°
12 - 12 Size 2 4 2 4
03 - 135°
3 Seal Material
04 - 180°
N - Buna N 3 1
33 11 3 1
See page D-35 for lever position
V - Viton
E F
2 4 2 4
2 4 2 4

3 1 3 1
3 1 3 1

5
Dentent Option
2 4 2 4
2 4
O - Spring Return
6 Lever
3 1 3 1
3L - Lever
1

7
2 Housing
4 Material
Blank - Cartridge only
A - Aluminum
38 1
Port Size
CODE PORT SIZE HOUSING NUMBER
Aluminum
0 Cartridge Only
A4G 1/2" BSPP 5986431-001
A6G 3/4" BSPP 5986432-001
A8H SAE 8 5986433-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001
See section J for housing details.

D-36 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


MLV9-12
4-Way, 3-Position, screw-in cartridge manual lever valve

Dimensions
mm (inch)

Torque cartridge in alu-


minum or steel housing D
34-41 Nm (25-30 ft. lbs).

SPARE PARTS
Lever 21113

Lever Position

WARNING
Maintain 5-8Nm (4-6 ft. lbs)
maximum torque on valve
tube nut. Overtightening
may cause valve failure.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-37


MPV1-10
Manual pull valve

Description Operation
The MPV1-10 is a 2-way, This valve blocks flow form
2
2 position, manually oper- port 2 to port 1 and will
ated, normally closed, allow flow form port 1 to
pull-to-open, directional port 2 when the spring
screw-in cartridge valve. bias is overcome.
1

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
1 Internal leakage (port 2 to port 1) 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg (0.24 lbs)
Seal kit 565803 (Buna-N)
566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curve 0 10 20 30 40 50
Cartridge only 70 5
2
60
Pressure Drop - bar
Pressure Drop - psi

4
50
1
40 3

Caution 30 2
Back pressure of 20 Flow - L/min (21,8 cSt oil @ 49°C)
• 1
16 bar (240 psi) 10
will unseat the poppet. 0 10 20 30 40 50
070 50
600 5 10
Pressure Drop - bar
Pressure Drop - psi

4
50 Flow - USgpm (105 SUS oil @ 120°F)
40 3

30 2
20
1
10
0 0
0 5 10
Flow - USgpm (105 SUS oil @ 120°F)
D-38 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
Model Code MPV1-10

MPV1 – 10 (V) – *– **– 00

1 2 3 4 5 6

D
1Function 3 Seals 5 Port size
MPV1 - Manual pull valve Blank - Buna-N O - Cartridge only
V - Viton®
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
4 Type Light duty Fatigue rated
10 - 10 Size
T - Stem only 3B 3/8” BSPP 02-175462 –
K - Knob 6T SAE 6 566151 –
2G 1/4” BSPP – 876702
3G 3/8” BSPP – 876703
6H SAE 6 – 876700
8H SAE 8 – 876701
See section J for housing details.

6 Special features
00 - None SS - 316 Stainless Steel
(Only required if valve has external components
special features, omitted
if “00”)
Dimensions
mm (inch)

Torque cartridge in 3,18 (0.125)


aluminum housing travel Nameplate bearing instruction “Pull”
Pull force require 16Nm (12 lbf ft)
47-54 Nm (35-40 ft. lbs)

41,3
(1.63)
25,4 (1.0) hex

0.875" -14 Thd.


31,7
(1.25)
2

1
Ø 15,80 (0.622)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-39


MPV3-10
Manual pull valve
with detent

Description Operation
The MPV3-10 is a 2-way, This valve blocks flow form the valve is actuated free
2 position, manually operat- port 2 to port 1 and will flow is allowed in both
ed, normally closed, pull-to- allow flow form port 1 to directions.
open, directional screw-in port 2 when the spring
cartridge valve, with detent. bias is overcome. When

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Internal leakage (port 2 to port 1) 5 drops/min. maximum @ 210 bar (3000 psi)
1
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg (0.24 lbs)
Seal kit 565803 (Buna-N)
566086 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curve
0 10 20 30 40 50
Cartridge only 5
70
60
Pressure Drop - bar
Pressure Drop - psi

4
50
2 40 3

30 2
1 20
1
10
Caution 0 0
• Back pressure of 0 5 10
16 bar (240 psi)
will unseat the poppet. Flow - USgpm (105 SUS oil @ 120°F)

D-40 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MPV3-10

MPV3 10 * ** 00

1 2 3 4 5

D
1 Function 3 Seals 5 Special features
MPV3 - Manual pull valve, N - Buna-N 00 - None
with detent V - Viton®0 (Only required if valve has
special features, omitted
if “00”)
2 Size 4 Port size
10 - 10 Size 00 - Cartridge only

CODE PORT SIZE HOUSING NUMBER


Aluminum Aluminum
Light duty Fatigue rated
3B 3/8” BSPP 02-175462 –
6T SAE 6 566151 –
2G 1/4” BSPP – 876702
3G 3/8” BSPP – 876703
6H SAE 6 – 876700
8H SAE 8 – 876701
See section J for housing details.

Dimensions 38,1
mm (inch) (1.500)
3,18
Torque cartridge in (0.125)
aluminum housing travel
47-54 Nm (35-40 ft. lbs)

52,2
(2.134)

85,9
(3.381) 25,4
(1.0)
Hex

0.875"-14 Thd.

31,7
(1.25) 2

1
Ø 15,80 (0.622)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-41


MSV1-12
Manual ‘push and
twist’ valve

Description Operation
The MSV1-12 is a 3-way, 2 In the normal position, the In the actuated position,
position manual ‘push and valve allows flow from port flow is allowed from port 3
twist’ to actuate type valve. 1 to port 2 while port 3 is to port 1 while port 2 is
blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 41,8 L/min (11 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,29 kg (0.66 lbs)
Seal kit 9900171-000 (Buna-N)
9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
Cartridge only A - P1 to P2
B - P3 to P1

160

3 140

120
Pressure Drop - psi

100
2
B
80
A
60
1
40

20

0
0 1 2 3 4 5 6 7 8 9 10 11
Flow (gpm)

D-42 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV1-12

MSV1 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV1 - 3-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 10 Size

5 Port Size
3 Seals
0 - Cartridge only
Blank - Buna-N
V - Viton®0 CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 02-161816
A12H SAE 12 02-160646

Dimensions
mm (inch)
38,1 (1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

67,8 (2.67)

22,1
(.870)
23,9
(.940)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-43


MSV2-12
Manual ‘push and
twist’ valve

Description Operation
The MSV2-12 is a 3-way, 2 In the normal position, the In the actuated position,
position manual ‘push and valve allows flow from port flow is allowed from port 2
twist’ to acutate type valve. 1 to port 3 while port 2 is to port 1 while port 3 is
blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 38 L/min (10 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,29 kg (0.66 lbs)
Seal kit 9900171-000 (Buna-N)
9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
A - P2 to P1
Cartridge only
B - P1 to P3

160

140
3
120
Pressure Drop - psi

100
2 B
80
A
60
1
40

20

0
0 1 2 3 4 5 6 7 8 9 10 11
Flow (gpm)

D-44 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV2-12

MSV2 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV2 - 3-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size

3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 02-161816
A12H SAE 12 02-160646

Dimensions
mm (inch)
38,1 (1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

67,8 (2.67)

22,1
(.870)
23,9
(.940)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-45


MSV5-12
Manual ‘push and
twist’ valve

Description Operation
The MSV5-12 is a 3-way, 2 In the normal position, the In the actuated position,
position manual ‘push and valve allows flow from port flow is allowed from port 3
twist’ to actuate type valve. 2 to port 1 while port 3 is to port 2 while port 1 is
blocked. blocked.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 41,8 L/min (11 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,29 kg (0.66 lbs)
Seal kit 9900171-000 (Buna-N)
9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
Cartridge only A - P2 to P1
B - P3 to P2

160

140
3
120
Pressure Drop - psi

100
2 B
80
A
60
1
40

20

0
0 1 2 3 4 5 6 7 8 9 10 11
Flow (gpm)

D-46 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV5-12

MSV5 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV5 - 3-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size

3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 02-161816
A12H SAE 12 02-160646

Dimensions
mm (inch)
38,1 (1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

67,8 (2.67)

22,1
(.870)
23,9
(.940)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-47


MSV3-12
Manual ‘push and
twist’ valve

Description Operation
The MSV3-12 is a 4-way, 2 In the normal position, all allowed from port 3 to port
position manual ‘push and ports are blocked. In the 4 and from port 2 to port 1.
twist’ to actuate type valve. actuated position, flow is

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 53,2 L/min (14 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,32 kg (0.71 lbs)
Seal kit 02-160979 (Buna-N)
02160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
Cartridge only A - P3 to P4
B - P2 to P1

160
4
140

3 120
Pressure Drop - psi

100

2 80 B

60 A

1 40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow (gpm)

D-48 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV3-12

MSV3 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV3 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size

3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001

Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

90,9 (3.58)

20,6
(.810)
22,1
(.872)
23,7
(.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-49


MSV4-12
Manual ‘push and
twist’ valve

Description Operation
The MSV4-12 is a 4-way, 2 In the normal position, flow In the actuated position, all
position manual ‘push and is allowed from port 3 to ports are blocked.
twist’ to actuate type valve. port 4 and from port 2 to
port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 53,2 L/min (14 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,32 kg (0.71 lbs)
Seal kit 02-160979 (Buna-N)
02160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
Cartridge only A - P3 to P4
B - P2 to P1

160
4
140

3 120
Pressure Drop - psi

100

2 80 B

60 A
1 40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow (gpm)

D-50 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV4-12

MSV4 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV3 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size

3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001

Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

90,9 (3.58)

20,6
(.810)
22,1
(.872)
23,7
(.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-51


MSV6-12
Manual ‘push and
twist’ valve

Description Operation
The MSV6-12 is a 4-way, 2 In the normal position, all port 2 and from port 4 to
position manual ‘push and ports are blocked. In the port 1.
twist’ to actuate type valve. actuated position, flow is
allowed from port 3 to

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 53,2 L/min (14 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,32 kg (0.71 lbs)
Seal kit 02-160979 (Buna-N)
02-160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
Cartridge only A - P4 to P1
B - P3 to P2

4 160

140
3
120
Pressure Drop - psi

100
2 B
80

60 A
1
40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow (gpm)

D-52 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV6-12

MSV6 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV6 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size

3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001

Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

90,9 (3.58)

20,6
(.810)
22,1
(.872)
23,7
(.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-53


MSV7-12
Manual ‘push and
twist’ valve

Description Operation
The MSV7-12 is a 4-way, 2 In the normal position, flow In the actuated position,
position manual ‘push and is allowed from port 3 to flow is allowed from port 3
twist’ to actuate type valve. port 4 and from port 2 to to port 2 and from port 4 to
port 1. port 1.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
3 1 Internal leakage 350 cc/min (21.5 in3/min)
Temperature range -40° to 120°C (-40° to 248°F)
Profile View Cavity C-12-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,32 kg (0.71 lbs)
Seal kit 02-160979 (Buna-N)
02-160980 (Viton®)
Viton is a registered trademark of E.I. DuPont

Pressure Drop
Curve
Cartridge only A - P4 to P1, P3 to P2
B - P2 to P1, P3 to P4

4 160

140

3 120
Pressure Drop - psi

100
2 B
80
A
60
1
40

20

0
0 1 2 3 4 5 6 7 8 9 10 11 12
Flow (gpm)

D-54 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code MSV7-12

MSV7 – 12 * – L– ****– **

1 2 3 4 5 6

6
D
1 Function 4 Actuation Option Special features
MSV7 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size

5 Port Size
3 Seals
0 - Cartridge only
Blank - Buna-N
V - Viton®0 CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001

Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)

68,1 (2.68)

90,9 (3.58)

20,6
(.810)
22,1
(.872)
23,7
(.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-55


DSV2-8
Shuttle valve

1 3

1 3
Description Operation
The DSV2-8-B is a direct The DSV2-8-B shuttle valve
acting, ball2type, shuttle senses the higher of two
valve. pressures at port 3 or port
1 and directs it to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
1 3 Typical application pressure (all ports) 240 bar (3500 psi) steel housing
Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated flow 23 L/min (6 USgpm)
2 Internal leakage Between ports 2 and 1, and 2 and 3;
5 drops/min. maximum @ 240 bar (3500 psi)
Sectional View Cavity C-8-3
3 Standard housing materials Aluminum or steel
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
2 MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,06 kg (0.14 lbs)
Seal kit 02-160755 (Buna-N)
3 02-160756 (Viton®)
1
Viton is a registered trademark of E.I. DuPont

2
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curves
0 8 16 22
Pressure Drop - psi

Pressure Drop - bar


Cartridge only 300 20
1
250
16
3 200
A - Port 1 to Flow - L/min (21,8 cSt oil @ 49°C) 12
port 2 150
0 8 16 22 A
2 B - Port 3 to 300 100 20 8
B
port 2
250 50 4
Pressure Drop - bar
Pressure Drop - psi

16
1 200 0 0
0 2 4 126
150
Flow - USgpm (105 SUS oil @A120°F)
8
100 B
Flow - L/min (21,8 cSt oil @ 49°C)
50 0 4
8 16 22 20
300 20
0 0
2500 2 4 6
Pressure Drop - bar
Pressure Drop - psi

Flow - USgpm (105 SUS oil @ 120°F) 16


200
12
150
A 20
8
100 B
D-20 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007

50 4
Model Code DSV2-8

DSV2 – 8 (V) – B – (*) – **– 00

1 2 3 4 5 6 7

D
1 Function 4 Style 6
Port size
DSV2 - Shuttle valve B - Ball O - Cartridge only

CODE PORT SIZE HOUSING NUMBER


2 Size 5 Valve housing material Aluminum Steel
8 - 8 Size Omit for cartridge only Fatigue rated Fatigue rated
A - Aluminum 4T SAE 4 02-160741 02-160745
S - Steel 6T SAE 6 02-160742 02-160746
3 Seals 2G 1/4” BSPP 02-160739 02-160743
Blank - Buna-N 3G 3/8” BSPP 02-160740 02-160744
V - Viton®
See section J for housing details.

7Special features
00 - None
(Only required if valve has
special features, omitted
if “00”)
SS - 316TI Stainless Steel
external components

Dimensions 22,2 (.875) Hex


mm (inch)
8,6 (0.34)
Torque cartridge in
aluminum or steel housing 0.750?"-16 Thd.
34-41 Nm (25-30 ft. lbs)

40,6 3
(1.60)

Ø 14,2 (0.559)

Ø 15,8 (0.622) Aluminum hous-


ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).21

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-21


PSV2-8
Pressure sequence valve
Direct acting, external pilot,
internal drain

Description Operation
The PSV2-8 is an externally The PSV2-8 remains closed
piloted, direct acting, sliding until the predetermined
spool, adjustable, pressure pressure is reached at port
sequence valve. 1, which then allows flow
from port 3 to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
3 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Sequence pressure ranges 13 – 3,4–90 bar (50–1300 psi)
2 30 – 35–210 bar (500–3000 psi)
1 Rated flow 23 L/min (6 USgpm)
Reseat pressure More than 90% of cracking pressure
Internal leakage 82 cm3/min. (5 in3/min) @ 210 bar (3000 psi)
Sectional View
Hysteresis less than 3 bar (45 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–8–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,21 kg (0.47 lbs)
Seal kits 02–160755 Buna N
02–160756 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49ºC)


3 Port 3 to 2, 0 4 8 12 12 20
2
valve fully open 300 20
Cartridge only
Pressure Drop - psi

Pressure Drop - bar


1
200 14

100 7

0 0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120ºF)

E-50 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PSV2-8

PSV2 – 8 (V) – * – (*) – ** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 5 Valve housing material 7 Sequence pressure 8 Pressure setting


PSV2 - Pressure sequence Omit for cartridge only range Optional - Specify in 100 psi
A - Aluminum 13 - 3,4-90 bar (50-1300 psi) increments If not specified,
2 Size Maximum operating pressure 30 - 35-210 bar set at:
(500-3000 psi) 13 - 44 bar (650 psi)
E
8 - 8 Size 210 bar (3000 psi)
30 - 100 bar (1500 psi)
3 Seals 6 Port size

Blank - Buna-N 0 - Cartridge only


9 Special features
V - Viton®
CODE PORT SIZE HOUSING NUMBER 00 - None
4 Adjustment (Only required if valve has
Aluminum
C - Cap Fatigue rated
special features, omitted
K - Knob if “00”)
4T SAE 4 02–160741
S - Screw
6T SAE 6 02–160742
2G 1/4” BSPP 02–160739
3G 3/8” BSPP 02–160740
See section J for housing details.

Dimensions
mm (inch)

Torque cartridge in
aluminum or steel housing "S" Adjustment
4,0 (0.15) hex

"C" Adjustment
12,7 (0.50) hex K option knob
Ø 31,8 (1.25)
68,3 76,5 79,2 nominal
(2.68) (3.02) (3.12)
53,8
(2.13) Full
71,3 out
(2.81)
Full 22,2 (0.87) hex
out

0.750"-16Thd.
3
40,9
(1.61)
2

1
Ø14,2 (0.559)
Ø15,8 (0.622)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-51


PSV4-8
Pressure sequence valve
Direct acting, external pilot,
internal drain, high pressure

Description Operation
The PSV4-8 is an external The PSV4-8 remains closed
pilot, direct acting, sliding until a predetermined
spool, adjustable, pressure pressure is applied at pilot
sequence valve. port 1, which then allows
flow from port 3 to port 2.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar ( 4000 psi)
3
Rated flow 15 L/min (4 USgpm)
2 Sequence pressure ranges 15 – 28–100 bar (400–1500 psi)
30 – 3,4–210 bar (50–3000 psi)
1 50 – 124–350 bar (1800–5000 psi)
Reseat pressure More than 90% of cracking pressure
Sectional View Internal leakage 5 in3/min @ 210 bar (3000 psi)
Hysteresis less than 3 bar (45 psi)
Temperature range -40° to 120°C (-40° to 248°F).
Cavity C–8–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,21 kg (0.47 lbs)
Seal kits 02–160755 Buna N
02–160756 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curve


3
Port 3 to 2, valve fully open
2 Cartridge only Flow - L/min (21,8 cSt oil @ 49°C)
0 4 8 12
1
300 20
Pressure Drop - bar
Pressure Drop - psi

200 14

100 7

0 0
0 1 2 3 4

Flow in USgpm (105 SUS oil @ 120°F)

E-52 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PSV4-8

PSV4 – 8 (V) – * – (*) – ** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 6Port size 9 Special features

PSV4 - Pressure sequence 0 - Cartridge only 00 - None


valve CODE PORT SIZE HOUSING NUMBER (Only required if valve has
special features, omitted
2 Size
Aluminum Steel
if “00”)
E
Fatigue rated Fatigue rated
8 - 8 Size 4T SAE 4 02–160741 02-160745
3 Seals 6T SAE 6 02-160742 02–160746
Blank - Buna-N 2G 1/4” BSPP 02-160739 02–160743
V - Viton® 3G 3/8” BSPP 02-160740 02-160744
See section J for housing details.
4 Adjustment
C - Cap
K - Knob 7 Sequence pressure 8 Pressure setting
S - Screw
range Optional - Specify in
5 Valve housing material 15 - 28-100 bar 100 psi increments.
Omit for cartridge only (400-1500 psi) If not specified, set at:
30 - 3,4-210 15 - 52 bar (750 psi)
S - Steel 30 - 100 bar (1500 psi)
(50-3000 psi)
A - Aluminum 50 - 175 bar (2500 psi)
50 - 124-350 bar
(1800-5000 psi)

Dimensions
mm (inch)
"S" Adjustment
"S" Adjustment
Torque cartridge in 4,0 hex
4,0(0.15)
hex (0.15)
steel or aluminum
"C"Adjustment
"C"Adjustment
housing 34-41 Nm
(25-30 ft. lbs) 12,7 (0.50)
12,7 (0.50)
hex hex K option
K option
knob knob
Ø 31,8
Ø (1.25)
31,8 (1.25)
68,3 68,3 76,5 76,5
79,2 79,2 nominal
nominal
(2.68)(2.68) (3.02)(3.02)
53,8 53,8 (3.12)(3.12)
(2.13)(2.13) 71,3 71,3 Full Full
(2.81)(2.81) out out
Full Full
out out 22,2 (0.87)
22,2 (0.87)
hex hex

Aluminum
0.750"-16
0.750"-16
Thd. Thd. housings can
3 3 40,9 40,9
• be used for
(1.61)(1.61)
pressures up
2 2
to 210 bar (3000 psi).
Steel housings must be
1 1 used for operating pres-
Ø 14,2
Ø (0.559)
14,2 (0.559)
Ø 15,8
Ø (0.622)
15,8 (0.622) sures above 210 bar
(3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 E-53


PCS3-12
Pressure compensator

Description Operation
The PCS3-12 is a This valve, when used with flow. This is based on what changes downstream on
screw-in, pressure either a fixed or variable ever pressure differential is port 2.
compensator cartridge. orifice between port 1 and chosen. Flow out of port 2,
port 3, maintains a constant regardless of pressure,

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 240 bar (3500 psi)
Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated flow 58 L/min (15 USgpm)
Functional Symbols Cavity C–12–3
Standard housing materials Customized housings are
Variable necessary for close-coupling,
or fixed the compensator and orifice
restrictor
upstream Temperature range -40° to 120°C (-40° to 248°F)
3 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
1 Weight cartridge only 0,30 kg (.55 lbs)
Seal kits 9900333-000 Buna-N
9900334-000 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View Performance A – 2,8 bar (40 PSI) Control


Characteristics DP
Cartridge only B – 5,5 bar (80 PSI) Control
DP
C – 11,0 bar(160 PSI) Control
DP
0.300
A
0.250 B
EXTERNAL ORIFICE DIAMETER (INCH)

C
0.200
3
0.150

2 0.100

0.050
1
0.000
0 5 10 15
FLOW (GPM)

I-24 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS3-12

PCS3 – 12 (V) – * (S) – *** – 00

1 2 3 4 5 6 7

1 Function 3 Seals 5Spool seals 6 Pressure differential


PCS3 – Pressure Blank – Buna-N Blank – No seal on spool. (nominal)
compensator restrictive type V – Viton S– Seal on spool. 40 – 2,8 bar (40 psi)
(For load holding applications 80 – 5,5 bar (80 psi)
2 Size 4 Port size where leakage from port 1 to 160 – 8,3 bar (120 psi)
12 – 12 Size 0 – Cartridge only 2 could cause cylinder drift,
7 Special features
(Customized housings are use of seal will increase
necessary for close-coupling, hysteresis) 00 – None
compensator and orifice) (Only required if valve has
special features, omit if 00)

Dimensions
mm (inch)

I
Torque into aluminum 31,7 (1.25) HEX
housing to 81-95Nm
(60-70 ft. lbs) 33,3 (1.31)

1 1/16-12 UNF -
2A THREAD

68,6 (2.70)

.873 ± .001
.935 ± .001

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-25


PCS3-16
Pressure compensator

Description Operation
The PCS3-16 is a This valve, when used with flow. This is based on what- of pressure, changes
screw-in, pressure either a fixed or variable ever pressure differential is downstream on port 2.
compensator cartridge. orifice between port 1 and chosen. Flow out of port 2,
port 3, maintains a constant regardless

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 114 L/min (30 USgpm)
Functional Symbols
Cavity C–16–3
Standard housing materials Customized housings are
Variable necessary for close-coupling
or fixed the compensator and orifice
restrictor
upstream Temperature range -40° to 120°C (-40° to 248°F)
3 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
1 Weight cartridge only 0,38 kg (0.84 lbs)
Seal kits 565811 Buna-N
889610 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Performance A – 2,8 bar (40 psi) (control P)


Characteristics B – 5,5 bar (80 psi) (control P)
Cartridge only C – 11,0 bar (160 psi) (control P)

Controlled flow - L/min (21,8 cSt oil @ 49° C)


0 12 24 36 48 60 72 84 96 108
Approx. orifice diameter - inches

0.400 10
Approx. orifice diameter - mm

0.350
3 A 8
0.300
B
0.250
C 6
0.200
0.150 4
2
0.100
2
0.050
0 0
0 3 6 9 12 15 18 21 24 27 30
1 Controlled flow - USgpm (105 SUS oil @ 120° F)

I-26 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS3-16

PCS3 – 16 (V) – * – (S) – *** – 00

1 2 3 4 5 6 7

1 Function 3 Seals 5 Spool seals 6Pressure differential


PCS3 – Pressure Blank – Buna-N Blank – No seal on spool (nominal)
compensator restrictive type V – Viton S – Seal on spool 40 – 2,8 bar (40 psi)
(For load holding applications 80 – 5,5 bar (80 psi)
2 Size 4 Port size where leakage from port 1 160 – 11,0 bar (160 psi)
16 – 16 Size 0 – Cartridge only to 2 could cause cylinder
7 Special features
(Customized housings are drift, use of seal will increase
necessary for close-coupling, hysteresis) 00 – None
compensator and orifice) (Only required if valve has
special features, omit if 00)

Dimensions
mm (inch)
28,6 38,1 (1.50) hex
(1.12) I
Torque into aluminum
housing to 108-122 Nm
(80-90 ft. lbs)
1.312 -12 Thd.

73,0 3
(2.87)

1
26,95 (1.061)
28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-27


PCS3-20
Pressure compensator

Description Operation
The PCS3-20 is a This valve, when used with flow. This is based on what- pressure, changes down-
screw-in, pressure either a fixed or variable ori- ever pressure differential is stream on port 2.
compensator cartridge. fice between port 1 and chosen. Flow out of port 2,
port 3, maintains a constant regardless of
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 189 L/min (50 USgpm)
Functional Symbols Cavity C–20–3
Standard housing materials Customized housings are
necessary for close-coupling
Variable the compensator and orifice
or fixed
restrictor Temperature range -40° to 120°C (-40° to 248°F)
upstream Fluids All general purpose hydraulic fluids such as:
3 2
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
1 Weight cartridge only 0,88 kg (1.94 lbs)
Seal kits 889616 Buna-N
02-175433 Viton®
Viton is a registered trademark of E.I. DuPont

Sectional View

Performance A – 2,8 bar (40 psi) (control P)


Characteristics B – 5,5 bar (80 psi) (control P)
Cartridge only

Controlled flow in L/min (21,8 cSt oil @ 49° C)


Approx. orifice diameter - inches

0 40 80 120 160 200


Approx. orifice diameter - mm

20
3 0.700
16
0.600
A
0.500 12
B
0.400
2 0.300 8
0.200
4
0.100
0 0
1 0 10 20 30 40 50
Controlled flow USgpm (105 SUS oil @ 120° F)

I-28 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code PCS3-20

PCS3 – 20 (V) – * – (S) – *** – 00

1 2 3 4 5 6 7

1 Function 3 Seals 5 Spool seals 6 Pressure differential


PCS3 – Pressure Blank – Buna-N Blank – No seal on spool (nominal)
compensator restrictive type V– Viton S – Seal on spool. 40 – 2,8 bar (40 psi)
(For load holding applications 80 – 5,5 bar (80 psi)
2 Size 4 Port size where leakage from port 1
7 Special features
20 – 20 Size 0 – Cartridge only to 2 could cause cylinder
(Customized housings are drift, use of seal will 00 – None
necessary for close-coupling, increase hysteresis) (Only required if valve has
compensator and orifice) special features, omit if 00)

Dimensions
mm (inch)

41,3 47,6 (1.87) hex I


Torque into aluminum (1.62)
housing to 128-155 Nm
(95-115 ft. lbs)
1.625 -12 Thd.

3
98,4
(3.87)
2

1
33,30 (1.311)
36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-29


PTS2-16
Pilot to shift valve

3
1

2 4
Description Operation
The PTS2-16 is a 3-way, This valve allows flow spring bias is overcome. cross-over transition, all
2 position, pilot operated, between ports 2 and 3 At that time, flow is directed ports are blocked. The
directional screw-in car- while blocking port 4 until between ports 3 and 4 while spring chamber for this
3
tridge valve. sufficient pressure has been blocking port 2. During the valve is internally vented
1 applied to port 1 and the to port 4 (tank).

Functional Sym2bol4 RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
1 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
2 4 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Pilot displacement volume 1,97 cm3 (0.12 in3)
Cavity C-16-4
3 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2 Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
Seal kit 889634 (Buna-N)
4 889638 (Viton®)
1
Viton is a registered trademark of E.I. DuPont

3
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curve
4 0 20 40 60 80 100 110
2 Cartridge only
6
80
5
Pressure Drop - bar

3 2
Pressure Drop - psi

70
1 to
60
or3 4
50 3
2 to
4 3
40 rt @ 49°C)
Flow - L/min (21,8 cStPooil
30 2
0 20 40 60 80 100 110
1 20
16
10
80
2 05
Drop - bar
Drop - psi

0
70
5 10 15 20 25 0 30 to 35
60 Flow - L/min (21,8 cSt oil @ 49°C) 3
or 4
50 Flow
0 - USgpm
20 40 (105
60SUS80oil @100 120°F)
3 110
to
t4 63
ssure Drop - Pressure
ssure Drop - Pressure

40 r
80 P o
30 36
52
bar

2
psi

70
20 to
3
60
10 or 41
50 3
0 to 0
D-64 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 4 3
40 0 5 10 15 20 r 25 t 30 35
30 Po
2
Model Code PTS2-16

PTS2 – 16 (V) – ***– ***– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS2 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features

6B 3/4” BSPP 02-175468 – 00 - None


3 Seals (Only required if valve has
10H SAE 10 – 876729
Blank - Buna-N special features, omitted
12H SAE 12 – 876731
V - Viton® if “00”)
4G 1/2” BSPP – 876728 SS - 316TI Stainless Steel
6G 3/4” BSPP – 876730 external components
See section J for housing details.

Dimensions
mm (inch) 28,6 38,1 (1.5) h ex
Torque cartridge in (1.12)
aluminum housing
47-54 Nm (35-40 ft. lbs) 1.312"-12 Thd.

101,6
(4.00)
3

1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-65


37
PTS2-20
Pilot to shift valve

3
1

Description 4 Operation
The PTS2-20 is a 3-way, This valve allows flow spring bias is overcome. cross-over transition, all
2 position, pilot operated, between ports 2 and 3 At that time, flow is directed ports are blocked. The
directional screw-in car- while blocking port 4 until between ports 3 and 4 while spring chamber for this
tridge valve. sufficient pressure has been blocking port 2. During the valve is vented internally
applied at port 1 and the to port 4 (tank).
3
Fun1ctional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
1 2
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
4 Rated flow 265 L/min (70 USgpm)
2 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
4 Pilot pressures 40 - 2,75 bar (40 psi)
4 80 - 5,5 bar (80 psi)
Pilot displacement volume 6,72 cm3 (0.41 in3)
Sectional View Cavity C-20-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
Seal kit 565916 (Buna-N)
1 889646 (Viton®)
Viton is a registered trademark of E.I. DuPont

4
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curve
4 3 0 40 80 200 210 220 240
Cartridge only
6
80
Pressure Drop - bar
Pressure Drop - psi

3 2 70 5
2
to
3

60 4
or
3

50
to

2 3
4

1 40
rt
Po

30 2
20
1
10 1
Flow - L/min (21,8 cSt oil @ 49°C)
0 0
0 40 80 200 210 220 240
0 10 20 30 40 50 60 70
Flow - L/min (21,8 cSt oil @ 49°C) 6
80 Flow - USgpm (105 SUS oil @ 120°F)
Pressure Drop - bar
Pressure Drop - psi

70
0 40 80 200 210 220 240 5
2
to

6
3

80 60 4
or
3

70 50 38
ssure Drop - bar
ssure Drop - psi

5
to

2
to

3
4

40
rt

60
Po

4
or

30 2
3

50
to

D-66 EATON Vickers Screw-In Cartridge Valves 20 September, 2007


V-VLOV-MC001-E4 3
4

40
rt

10 1
Po

30 2
Model Code PTS2-20

PTS2 – 20 (V) – ***– **– 00

1 2 3 4 5 6

D
1Function 4 Port size V - Viton®
PTS2 - Pilot to shift valve O - Cartridge only
5 Pilot to shift (nominal)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
40 - 2,75 bar (40 psi)
Light duty Fatigue rated 80 - 5,5 bar (80 psi)
20 - 20 Size
16T SAE 16 566412 –
8B 1” BSPP 02-175469 – 6 Special features
3 Seals 12H SAE 12 – 876745 00 - None
Blank - Buna-N 16H SAE 16 – 876747 (Only required if valve has
6G 3/4” BSPP – 876744 special features, omitted
8G 1” BSPP – 876746 if “00”)
See section J for housing details.

Dimensions 47,6 (1. 875) hex


mm (inch) 41,3
(1.62)
Torque cartridge in
aluminum housing
128-155 Nm (95-115 ft. lbs)
1.625"-12 Thd.

139,7
(5.50)
3

1
Ø 31,70 (1.248)
Ø 33,30 (1.311)
Ø 36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-67


39
PTS3-16
Pilot to shift valve

2
Description 4 Operation
The PTS3-16 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 2 and 3 while internally vented to port
tridge valve. sufficient pressure has been blocking port 4. During the 4 (tank).
3 applied to port 1 and the cross-over transition, all ports

1
Functional Symbol RATINGS AND SPECIFICATIONS
2 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
Typical application pressure (all ports) 210 bar (3000 psi)
4
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
2 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
4
Pilot pressures 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Sectional View Pilot displacement volume 1,97 cm3 (0.12 in3)
Cavity C-16-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
1 Seal kit 889634 (Buna-N)
889638 (Viton®)
4 Viton is a registered trademark of E.I. DuPont

3 Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curve 0 20 40 60 80 100 110
4 Cartridge only 6
2 80
5
70
Pressure Drop - bar
2
Pressure Drop - psi

3
to

60
3

1 4
or
3

50
to

2 3
4

40
rt
Po

30 2
1 20 Flow - L/min (21,8 cSt oil @ 49°C)
1
10 0 20 40 60 80 100 110
0 0 6
080 5 10 15 20 25 30 35
5
70 Flow - L/min (21,8 cSt oil @ 49°C)
Pressure Drop - bar
2
Pressure Drop - psi

Flow - USgpm (105 SUS oil @ 120°F)


to

60
3

0 20 40 60 80 100 110 4
or

6
3

50
to

80 3 42
4

40 5
rt

70
Po

sure Drop - bar


2
sure Drop - psi

30 2
to

6020
3

4
or

1
3

5010
to

D-70 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 3


4

40 0 0
rt
Po

30 0 5 10 15 20 25 30 35
Model Code PTS3-16

PTS3 – 16 (V) – ***– ***– 16

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS3 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features

6B 3/4” BSPP 02-175468 – 00 - None


3 Seals (Only required if valve has
10H SAE 10 – 876729
Blank - Buna-N special features, omitted
12H SAE 12 – 876731
V - Viton® if “00”)
4G 1/2” BSPP – 876728 SS - 316TI Stainless Steel
6G 3/4” BSPP – 876730 external components
See section J for housing details.

Dimensions
mm (inch) 28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312"-12 Thd.

4
101,6
(4.00)
3

1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-71

43
PTS3-20
Pilot to shift valve

3
1

Description 4 Operation
The PTS3-20 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 2 and 3 while vented internally to port 4
tridge valve. sufficient pressure has been blocking port 4. During the (tank).
3 applied to port 1 and the cross-over transition, all ports
1

Functional Symbol RATINGS AND SPECIFICATIONS


2 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
1 4
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 265 L/min (70 USgpm)
2 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
4
Pilot pressures 2,75 bar (40 psi)
4 5,5 bar (80 psi)
Pilot displacement volume 6,72 cm3 (0.41 in3)
Sectional View
Cavity C-20-4
3 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
Seal kit 565916 (Buna-N)
1 889646 (Viton®)
Viton is a registered trademark of E.I. DuPont
4

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


3 Curve
40 80 200 210 220 240
4 Cartridge only 6
80
2
5
2

70
Pressure Drop - bar
Pressure Drop - psi

to

3
3

60
or

4
3

1 50
to

2 3
4

40
rt
Po

30 2
20
1 Flow - L/min (21,8 cSt oil @ 49°C) 1
10
40 80 200 210 220 240
0 06
800 10 20 30 40 50 60 70
5
2

70 Flow - L/min (21,8 cSt oil @ 49°C)


Pressure Drop - bar

USgpm (105 SUS oil @ 120°F)


Pressure Drop - psi

to
3

60 40 80 200 210 220 240


or

4
6
3

50
to

80
3 44
4

40
rt

5
2

70
essure Drop - bar
Po
ssure Drop - psi

to

30 2
3

60
or

20 4
3

50
to

10 1
3
4

40
rt

D-72 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Po

0 0
30 270
0 10 20 30 40 50 60
Model Code PTS3-20

PTS3 – 20 (V) – ***– **– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS3 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
Light duty Fatigue rated 6 Special features
20 - 20 Size
16T SAE 16 566412 – 00 - None
8B 1” BSPP 02-175469 – (Only required if valve has
3 Seals special features, omitted
12H SAE 12 – 876745
Blank - Buna-N if “00”)
16H SAE 16 – 876747
V - Viton®
6G 3/4” BSPP – 876744
8G 1” BSPP – 876746
See section J for housing details.

Dimensions
mm (inch) 47,6 (1. 875) hex
41,3
Torque cartridge in (1.62)
aluminum housing
128-155 Nm (95-115 ft. lbs)
1.625"-12 Thd.

4
139,7
(5.50)
3

Ø 31,70 (1.248)
Ø 33,30 (1.311)
Ø 36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-73


PTS1-10
Pilot to shift valve

3
1

2 4
Description Operation
The PTS1-10 is a 3-way, This valve allows flow spring bias is overcome. ports are blocked. The
2 position, pilot operated, between ports 2 and 3 At this time, flow is directed spring chamber for this
directional screw-in car-
3
while blocking port 4 until between port 3 and port 4 valve is externally vented
tridge
1 valve. sufficient pressure has been while blocking port 2. During to atmosphere.
applied to port 1 and the the cross-over transition, all

2 4
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 30 L/min (8 USgpm)
2 4 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Pilot displacement volume 0,49 cm3 (0.02 in3)
Cavity C-10-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,14 kg (0.32 lbs)
4 Seal kit 889625 (Buna-N)
1 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont
3

Pressure Drop Flow - L/min (21,8 cSt oil @ 490C)


2 Curve
4 5 10 15 20 25 30
Cartridge only 5
70
2
to

1 3 60
4
3
or

50
3
to

3
4

2 40
rt
Po

0
30 Flow - L/min (21,8 cSt oil @ 49 C)
5 10 15 20 25 302
20 5
1 70 1
2

10
to

60
04
3

0
or

50
3

0 1 2 3 4 5 6 7 8
to

0
Flow- USgpm
Flow - L/min (21,8 cSt oil
(105 SUS oil@@49 C)0F)
120 3
4

40
rt

5 10 15 20 25 30
Po

30 52
70
2

20 28
to

60
41
3

10
or

50
3
to

0
30
4

40 0 1 2 3 4 5 6 7 8
rt
Po

D-56 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


30 Flow - USgpm (105 SUS oil @ 1200F)
2
Model Code PTS1-10

PTS1 – 10 (V) – **– ***– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS1 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
10 - 10 Size Light duty Fatigue rated
3B 3/8” BSPP 02-179705 – 6 Special features

6T SAE 6 566161 – 00 - None


3 Seals (Only required if valve has
2G 1/4” BSPP – 876709
Blank - Buna-N special features, omitted
3G 3/8” BSPP – 876715
V - Viton® if “00”)
6H SAE 6 – 876708
8H SAE 8 – 876713
See section J for housing details.

Dimensions
25,4 (1.0) hex
mm (inch) 19,0
Torque cartridge in (0.75)
aluminum housing
47-54 Nm (35-40 ft. lbs) 0.875” - 14 Thd.

61,9
(2.44) 3

Ø 15,80 (0.622)
Ø 17,40 (0.685)
Ø 18,97 (0.747)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-57

29
PTS1-16
Pilot to shift valve

3
1

2 4
Description Operation
The PTS1-16 is a 3-way, This valve allows flow spring bias is overcome. over transition, all ports
2 position, pilot operated,
3 between ports 2 and 3 At this time, flow is are blocked. The spring
directional screw-in car- while blocking port 4 until directed between port 3 chamber for this valve is
1 valve.
tridge sufficient pressure has been and port 4 while blocking externally vented to
applied to port 1 and the port 2. During the cross- atmosphere.
2 4
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
Typical application pressure (all ports) 210 bar (3000 psi)
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
2 4 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Pilot displacement volume 1,97 cm3 (0.12 in3)
3 Cavity C-16-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
2 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
4 Weight cartridge only 0,5 kg (1.12 lbs)
1 Seal kit 889634 (Buna-N)
889638 (Viton®)
3 Viton is a registered trademark of E.I. DuPont

2 Pressure Drop Flow - L/min (21,8 cSt oil @ 490C)


Curve 20 40 60 80 100 110
4
Cartridge only 6
1 80
3 70 2 5
Pressure Drop - bar

to
Pressure Drop - psi

60 3 4
or
50 3
2 to
4
Flow - L/min (21,8 cSt oil @ 49t0C)
40 3
r
30 20 40 60 80 100 Po 110 2
1 20 6
80 1
70 10 5
2
Pressure Drop - bar

to
Pressure Drop - psi

60 0 0
3
0 5 10 15 20 o25 30 4 35
r
50 03
Flow - Flow
L/min- USgpm
(21,8 cSt(105
oil @SUS49 C) @ 1200F)
to oil
40 4 3
20 40 60 80 rt100 110
30 P o
62
8020 30
7010 2 51
sure Drop - bar

to
sure Drop - psi

60 0 3
r 40
o
50 0 5 10 15 20 253 30 35
to 3
40 t 4 @ 120 F)
D-58 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4
Flow - September,
USgpm (1052007 SUS oil 0

or
30 P 2
Model Code PTS1-16

PTS1 – 16 (V) – ***– ***– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS1 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features

6B 3/4” BSPP 02-175468 – 00 - None


3 Seals (Only required if valve has
10H SAE 10 – 876729
Blank - Buna-N special features, omitted
12H SAE 12 – 876731
V - Viton® if “00”)
4G 1/2” BSPP – 876728
6G 3/4” BSPP – 876730
See section J for housing details.

Dimensions
mm (inch) 38,1 (1.5) hex
28,6
Torque cartridge in
(1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs)
1.312”-14 Thd

101,6 3
(4.0)

1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-59


PTS1-20
Pilot to shift valve

3
1

2 4

Description Operation
The PTS1-20 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 2 and 3 At that time, flow is directed chamber for this valve is
directional screw-in car-
3 while blocking port 4 until between ports 3 and 4 while externally vented to atmos-
tridge valve. sufficient pressure has been blocking port 2. During the phere.
1 applied to port 1 and the cross-over transition, all ports

Functional Sym2bol 4 RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
Typical application pressure (all ports) 210 bar (3000 psi)
1
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 265 L/min (70 USgpm)
2 4 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 4 80 - 5,5 bar (80 psi)
Pilot displacement volume 6,72 cm3 (0.41 in3)
3 Cavity C-20-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
2 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 1,1 kg (2.40 lbs)
1 Seal kit 565916 (Buna-N)
4 889646 (Viton®)
Viton is a registered trademark of E.I. DuPont

3
Pressure Drop Flow - L/min (21,8 cSt oil @ 490C)
Curve 0 20 40 60 80 100 110
42
Cartridge only 6
80
3 70 2 5
Pressure Drop - bar

1 to
Pressure Drop - psi

60 3
or 4
50 3
2 to
4 3
40
ort
P
30 Flow - L/min (21,8 cSt oil @ 490C) 2
1 20 0 20 40 60 80 100 110
16
10
80
0
70 2 5
Pressure Drop - bar

o
Pressure Drop - psi

10 20 30 40 600 50 603 t 70
r 4
Flow - L/min (21,8 cSt oil @ 493 0oC)
0
50 Flow - USgpm (105 SUS oil @ o120 F)
0 20 40 60 80 100 t 110
4 3
40
ort 6
80 P
30 2 32
70 2 5
ressure Drop - bar

20 to
essure Drop - psi

60 3 1
10 or 4
50 3
0 to
t 4 3
40 0 10 20 30 r
40 o 50 60 70
D-60 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
P
30 Flow - USgpm (105 SUS oil @ 1200F) 2
Model Code PTS1-20

PTS1 – 20 (V) – ***– **– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS1 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
Light duty Fatigue rated 6 Special features
20 - 20 Size
16T SAE 16 566412 – 00 - None
8B 1” BSPP 02-175469 – (Only required if valve has
3 Seals special features, omitted
12H SAE 12 – 876745
Blank - Buna-N if “00”)
16H SAE 16 – 876747
V - Viton®
6G 3/4” BSPP – 876744
8G 1” BSPP – 876746
See section J for housing details.

Dimensions 47,6 (1.875) hex


mm (inch) 41,3
(1.62)
Torque cartridge in
aluminum housing
128-155 Nm (95-115 ft. lbs) 1.625”-12 Thd

139,7
(5.5) 3

1
Ø 31,70 (1.248)
Ø 33.30 (1.311)
Ø 36,47 (1.436)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-61

33
PTS5-10
Pilot to shift valve

2
4

3 1
Description Operation
The PTS5-10 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 1 and 2 At that time, flow is directed chamber for this valve is
directional screw-in car- while port 3 is blocked until between ports 2 and 3 while vented internally to port
tridge valve. sufficient pressure has been blocking port 1. During the 1.
2
applied at port 4 and the cross-over transition, all ports
4

Functional Symbol RATINGS AND SPECIFICATIONS


4 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
23 1 Typical application pressure (all ports) 210 bar (3000 psi)
4
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 11 L/min (3 USgpm)
Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
3 1 Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressure 3,45 bar (50 psi))
Pilot displacement volume 0,49 cm3 (0.02 in3)
Sectional View
Cavity C-10-3
4 Fluids All general purpose hydraulic fluids such as:
3 MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2 Standard housing materials Aluminum
Weight cartridge only 0,14 kg (0.32 lbs)
4 Seal kit 889624 (Buna-N)
889628 (Viton®)
1 Viton is a registered trademark of E.I. DuPont

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


3 Curves
0 2 4 6 8 10
Cartridge only 100 7
2 A
6
Pressure Drop - bar

80
Pressure Drop - psi

3 5
A - Port 3 to 2 60
1 B 4
B - Port 2 to 1
2 40 3

Flow - L/min (21,8 cSt oil @249°C)


20
0 2 4 6 8 1 10
1 100 7
0 0 A
0 6
80 1 2 3
Pressure Drop - bar
Pressure Drop - psi

Flow - Flow
USgpm- L/min
(105 (21,8 cSt@oil120°F)
SUS oil @ 49°C)
5
060 2 4 6 8 10
100 B 4
7
A 3 48
40
6
ressure Drop - bar

80
ressure Drop - psi

2
20 5
60 1
B 4
0 0
D-76 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 40
September, 2007 3
0 1 2 3
2
Flow - USgpm (105 SUS oil @ 120°F)
Model Code PTS5-10

PTS5 – 10 (V) – **– **– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS5 - Pilot to shift valve O - Cartridge only 50 - 3,45 bar (50 psi)

CODE PORT SIZE HOUSING NUMBER


2 Size Aluminum Aluminum 6 Special features

10 - 10 Size Light duty Fatigue rated 00 - None


3B 3/8” BSPP 02-173358 – (Only required if valve has
6T SAE 6 566162 – special features, omitted
3 Seals if “00”)
2G 1/4” BSPP – 876705
Blank - Buna-N 3G 3/8” BSPP – 876714
V - Viton®
6H SAE 6 – 876704
8H SAE 8 – 876711
See section J for housing details.

Dimensions 4
mm (inch)

Torque cartridge in 33,4 25,4 (1.0) h ex


aluminum housing (1.31)
47-54 Nm (35-40 ft. lbs)

0.875"-14 Thd.

46,0 3
(1.81)

1
Ø 15,80 (0.622)
Ø 17,40 ( 0.685)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-77


49
PTS5-16
Pilot to shift valve

2 4
Description Operation
The PTS5-16 is a 3-way, This valve allows flow spring bias is overcome. are open. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 3 and 2 while externally vented to
tridge valve. 3 sufficient pressure has been blocking port 4. During the atmosphere.
applied to port 1 and the cross-over transition, all ports
1

Functional Symbol RATINGS AND SPECIFICATIONS


2 4 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
1
Rated flow 132 L/min (35 USgpm)
Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
2 4 Temperature range -40° to 120°C (-40° to 248°F)
4 Pilot pressures 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
Profile View 160 - 11,0 bar (160 psi)
Pilot displacement volume 1,97 cm3 (0.12 in3)
3 Cavity C-16-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
2 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
4
Seal kit 889634 (Buna-N)
1 889638 (Viton®)
Viton is a registered trademark of E.I. DuPont

3
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
4
Curve 20 40 60 80 100 110
2
Cartridge only 6
80
3 70 5
Pressure Drop - bar

2
Pressure Drop - psi

1 60 to
3 4
or
2 50 3
to 3
40 t 4
r
30 Po cSt oil @ 49°C)2
Flow - L/min (21,8
20 20 40 60 80 100 110
1 1
10 6
80
0 0
0 70 5 5
Pressure Drop - bar

10 15 20 25 30 35 2
Pressure Drop - psi

o
60 Flow
Flow - L/min(105
- USgpm (21,8SUS
cSt oil
oil @ 49°C) 3 t
@ 120°F) 4
or
50 20 40 60 80 100 110 3
to 3
40 4 6
80 rt 50
30 Po 2
70 5
sure Drop - bar

2
sure Drop - psi

20 to
60 3 4 1
10 or
50 3 0
D-78 EATON Vickers Screw-In Cartridge Valves 0
V-VLOV-MC001-E4 September, 2007 to 3
40 0 5 10 t4
15 r20 25 30 35
Po
30
Model Code PTS5-16

PTS5 – 16 (V) – ***– ***– 00

1 2 3 4 5 6

D
1 Function 4 Port size V - Viton®
PTS5 - Pilot to shift valve O - Cartridge only
5 Pilot to shift (nominal)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
40 - 2,75 bar (40 psi)
Light duty Fatigue rated 80 - 5,5 bar (80 psi)
16 - 16 Size
12T SAE 12 566411 – 160 - 11,0 bar (160 psi)
6B 3/4” BSPP 02-175468 –
3 Seals 10H SAE 10 – 876729 6 Special features
Blank - Buna-N 12H SAE 12 – 876731 00 - None
4G 1/2” BSPP – 876728 (Only required if valve has
6G 3/4” BSPP – 876730 special features, omitted
See section J for housing details.
if “00”)

Dimensions 38,1 (1.5) hex


mm (inch) 28,6
Torque cartridge in (1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312”-14 Thd.

101,6
(4.00) 3

1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-79

51
PTS6-10
Pilot to shift valve

4 2
5

Descriptio3
n Operation
1
The PTS6-10 is a 4-way, This valve allows flow is overcome. At that time, blocked. The spring cham-
2 position, pilot operated, between ports 1 and 2 and flow is directed between ber for this valve is vented
directional screw-in car- ports 3 and 4 until sufficient ports 1 and 4 and ports 3 internally to port 1.
tridge valve. pressure has been applied and 2. During the cross-over
4 2 at port 5 and the spring bias transition, all ports are

5
Functional Symbol RATINGS AND SPECIFICATIONS

5 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
5 3 1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
3 1 Pilot pressure 4,2 bar (60 psi)
Pilot displacement volume 0,49 cm3 (0.02 in3)
Sectional Vie4w Cavity C-10-4
Fluids All general purpose hydraulic fluids such as:
5 MIL-H-5606, SAE 10, SAE 20, etc.
3 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
2 Weight cartridge only 0,15 kg (0.33 lbs)
5 Seal kit 889625 (Buna-N)
566080 (Viton®)
1 Viton is a registered trademark of E.I. DuPont

4 Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


Curves
0 4 8 12 16 20
Cartridge only 7
3 100
A B
42 6
80
C
Pressure Drop - bar
Pressure Drop - psi

5
3 A - Port 3 to 4
1 B - Port 4 to 1 60 4
C - Port 3 to 2 D
2
D - Port 2 to 1 3
40 Flow - L/min (21,8 cSt oil @ 49°C)
0 4 8 12 16 20 2
1
20 100 7
A 1B
Flow - L/min (21,8 cSt oil @ 49°C) 6
0 0
0 80 10 24 38 412 516 620 C
Pressure Drop - bar
Pressure Drop - psi

5
Flow
100- USgpm (105 SUS oil @ 120°F) 7
60 A B
4
D 6
52
80 3
C
sure Drop - bar
sure Drop - psi

40 5
2
60 4
20 D
D-80 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 1
3
40
Model Code PTS6-10

PTS6 – 10 (V) – **– **– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS6 - Pilot to shift valve O - Cartridge only 60 - 4,2 bar (60 psi)

CODE PORT SIZE HOUSING NUMBER


2 Size Aluminum Aluminum 6 Special features

10 - 10 Size Light duty Fatigue rated 00 - None


3B 3/8” BSPP 02-179705 – (Only required if valve has
6T SAE 6 566161 – special features, omitted
3 Seals if “00”)
2G 1/4” BSPP – 876709
Blank - Buna-N 3G 3/8” BSPP – 876715
V - Viton®
6H SAE 6 – 876708
8H SAE 8 – 876713
See section J for housing details.

Dimensions Port 5, pilot, SAE 4 size


mm (inch) 5
Torque cartridge in
aluminum housing
47-54 Nm (35-40 ft. lbs) 33,3 25,4 (1.0) h ex
(1.31)

0.875"-14 Thd.

61,9 4
(2.43)
3

1
Ø 15,80 (0.622)
Ø 17,40 ( 0.685)
Ø 18,97 (0.747)

53
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-81
PTS6-16
Pilot to shift valve

Description 2 4 Operation
The PTS6-16 is a 3-way, This valve allows flow spring bias is overcome. are open. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 3 and 2 while externally vented to Port 4
tridge valve. 3 sufficient pressure has been blocking port 4. During the (tank).
applied to port 1 and the cross-over transition, all ports
1

Functional Symbol RATINGS AND SPECIFICATIONS


2 4
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
Typical application pressure (all ports) 210 bar (3000 psi)
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
2 4 Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Pilot displacement volume 1,97 cm3 (0.12 in3)
Cavity C-16-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
2 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
1 4 Seal kit 889634 (Buna-N)
889638 (Viton®)
Viton is a registered trademark of E.I. DuPont
3

Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)


4 2 Curve
0 20 40 60 80 100 110
Cartridge only
6
80
1 3
2 5
Pressure Drop - bar

70
Pressure Drop - psi

to
60
or3 4
2 3
50
to 3
40 t 4
Flow - L/min (21,8 cSt oilr @ 49°C)
30 Po
1 0 20 40 60 80 100 110 2
20
61
80
10
2 50
Pressure Drop - bar

700
Pressure Drop - psi

to
60 0Flow5- L/min
10 (21,8
15 cSt 20
oil @ 49°C)
25 30 3 35 4
or
500 Flow20 - USgpm
40 60(105 80
SUS oil 3
100@o120°F)110
t 3
40 4 6
o rt
80 P
30 2 54
2 5
ssure Drop - bar

70
ssure Drop - psi

20 to
3
60
10 or 4 1
50 3
0 to 3 0
D-82 EATON Vickers Screw-In Cartridge Valves 40 0 September,
V-VLOV-MC001-E4 2007 t 4
5 10 15 20or 25 30 35
30 P
Flow - USgpm (105 SUS oil @ 120°F) 2
Model Code PTS6-16

PTS6 – 16 (V) – ***– ***– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS6 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features

6B 3/4” BSPP 02-175468 – 00 - None


3 Seals (Only required if valve has
10H SAE 10 – 876729
Blank - Buna-N 12H special features, omitted
SAE 12 – 876731
V - Viton® if “00”)
4G 1/2” BSPPSAE 6 – 876728 SS - 316TI Stainless Steel
6G 3/4” BSPP – 876730 external components
See section J for housing details.

Dimensions
mm (inch) 28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312"-12 Thd.

4
101,6
(4.00)
3

1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-83

43
PTS7-10
Pilot to shift valve

3
1

2
Description Operation
The PTS7-10 is a 2-way, This valve allows flow The spring chamber for this
2 position, pilot operated, between ports 2 and 3 until valve is externally vented to
directional screw-in sufficient pressure at port 1 atmosphere.
cartridge valve.3 overcomes the spring bias,
1 which closes both ports.

Functional Sym2bol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 30 L/min (8 USgpm)
2 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
Sectional View 160 - 11,0 bar (160 psi)
Pilot displacement volume 0,49 cm3 (0.02 in3)
3
Cavity C-10-3
Fluids All general purpose hydraulic fluids such as:
2 MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,10 kg (0.23 lbs)
1
Seal kit 889624 (Buna-N)
889628 (Viton®)
3 Viton is a registered trademark of E.I. DuPont

2 Flow - L/min (21,8 cSt oil @ 49°C)


Pressure Drop
Curve 0 5 10 15 20 25 30
Cartridge only 70 5
1 3
60
4
Pressure Drop - bar
Pressure Drop - psi

2
50
3
40 Flow - L/min (21,8 cSt oil @ 49°C)
1
300 5 10 15 20 25 30
70 5 2
20
60
4 1
Pressure Drop - bar

10
Pressure Drop - psi

Flow - L/min (21,8 cSt oil @ 49°C)


50
00 5 10 15 30 3 0
20 25
40
70 0 1 2 3 4 5
7 85 6

30 Flow - USgpm (105 SUS oil @ 120°F)


60 2
4
essure Drop - bar
essure Drop - psi

20
50 56
1
10 3
40
D-84 EATON Vickers Screw-In Cartridge Valves 0
V-VLOV-MC001-E4 September, 2007 0
30 0 1 2 3 4 5 6 7 8 2
Model Code PTS7-10

PTS7 – 10 (V) – **– ***– 00

1 2 3 4 5 6

D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS7 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
10 - 10 Size Light duty Fatigue rated
3B 3/8” BSPP 02-173358 – 6 Special features
6T SAE 6 566162 – 00 - None
3 Seals (Only required if valve has
2G 1/4” BSPP – 876705
Blank - Buna-N special features, omitted
3G 3/8” BSPP – 876714
V - Viton® if “00”)
6H SAE 6 – 876704
8H SAE 8 – 876711
See section J for housing details.

Dimensions
mm (inch) 25,4 (1.0) hex
19,0
Torque cartridge in (0.75)
aluminum housing
47-54 Nm (35-40 ft. lbs)
0.875" -14 Thd.

46,0 3
(1.81)

1
Ø 15,82 (0.623)

Ø 17,42 (0.686)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-85


PTS9-8
Pilot to shift valve

Description Operation
The PTS 9-8 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is vented to port
come. At that time flow is 5.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 280 bar (4000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
5 1 PTS9-16
Rated inlet flow 19 L/min (5 USgpm)
Transition All ports open
3 Internal leakage 3
164 cc/min (10 in /min) @ 3000 PSID
Temperature range -40° to 100°C (-40° to 210°F)
Profile View Cavity C-8-5S
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
CF EF Filtration Cleanliness code 18/16/13
4 2 Standard housing material Aluminum or steel
Weight cartridge only
LS 5 1
Seal kitPFRD-XX

Performance
3 P Curves
5 Cartridge only
CF EF
200
44 2

LS 5 1 160
Pressure Drop - psi

PFRS-XX
3
120
3 P
2
80
A B B
2 4 S2 A
S1 1 40
SV9-8A
0
3 1 0.0 1.0 2.0 3.0 4.0 5.0
P T Flow - USgpm
A - Pressure drop port 3 to port 4
B - Pressure drop port 3 to port 2
A B
S1 2 4 S2

SV9-8B
D-86 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
3 1
P T
Model Code PTS9-8

PTS9 – 8 * – *– ***– ***– 00

1 2 3 4 5 6 7

D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
Port Port Aluminum Steel
2, 3 & 4 1&5
2 Size
000 No Body – – –
8 - C-8-5S Cavity

6 Shift Pressure 7 Special features


3 Seals 080 psi (5,5 bar) 00 - None
N - Buna-N 160 psi (11,0 bar) (Only required if valve has
V - Viton special features, omitted
if “00”)
* These model digits will not be stamped on the valve.

7/8" Hex
Dimensions .752
mm (inch) [19.1]
3/4" - 16 Thread
Torque cartridge in housing:
A - 34-41 Nm (25-30 ft. lbs)
S - 34-41 Nm (25-30 ft. lbs)

2.569 4
[65.25]

Aluminum hous-
1 ings can be used
.435
[11.05] • for pressures up
.497 to 210 bar (3000
[12.62] psi). Steel housings must be
.559 used for operating pressures
[14.2] above 210 bar (3000 psi).
.622
[15.8]

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-87


PTS9-10
Pilot to shift valve

Description Operation
The PTS 9-10 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is vented to port
come. At that time flow is 5.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 280 bar (4000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
5 1 Rated PTS9-16
inlet flow 38 L/min (10 USgpm)
Transition All ports open
3 Internal leakage 164 cc/min (10 in3/min) @ 3000 PSID
Temperature range -40° to 100°C (-40° to 210°F)
Profile View Cavity C-10-5S
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
CF EF Filtration Cleanliness code 18/16/13
4 2 Standard housing material Aluminum or steel
Weight cartridge only
LS 5 1
Seal kitPFRD-XX

5 Performance
3 P Curves
4 Cartridge only
CF EF
34 2 300

LS 5 1
PFRS-XX
2

1
3 P 200
Psid

A B
2 4 S2
S1
100
SV9-8A Port 3 to Port 2

3 1
P T
0
0 2 4 6 8 10
A B Gpm
S1 2 4 S2

SV9-8B
D-88 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
3 1
P T
Model Code PTS9-10

PTS9 – 10 * – *– ***– ***– 00

1 2 3 4 5 6 7

D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
Port Port Aluminum Steel
1, 2, 3 & 4 5
2 Size 000 No Body – – –
10 - C-10-5S Cavity

6 Shift Pressure 7 Special features


3 Seals
080 psi (5,5 bar) 00 - None
N - Buna-N 100 psi (6,9 bar) (Only required if valve has
V - Viton 160 psi (11,0 bar) special features, omitted
* These model digits will not be stamped on the valve.
if “00”)

1" Hex
Dimensions .813
mm (inch) [20.65]
Torque cartridge in housing: 7/8" - 14 Thread
A - 47-54 Nm (35-40 ft. lbs)
S - 68-75 Nm (50-55 ft. lbs)
5

3.069
[77.95] 4

.559 1
[14.2]
.622
[15.8] Aluminum hous-
.685
[17.4] .747 ings can be used
[18.97] • for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-89


PTS9-12
Pilot to shift valve

Description Operation
The PTS 9-12 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is vented to port
come. At that time flow is 5.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 280 bar (4000 psi)
5 1 Cartridge fatigue
PTS9-16 pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 76 L/min (20 USgpm)
Transition All ports open
3 Internal leakage 3
164 cc/min (10 in /min) @ 3000 PSID
Temperature range -40° to 100°C (-40° to 210°F)
Profile View Cavity C-12-5S
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
CF EF
4 2 Filtration Cleanliness code 18/16/13
Standard housing material Aluminum or steel
LS 5 1 Weight cartridge only 0,36 kg (0.79 lbs)
PFRD-XX
Seal kit (Urethane) 202914-921

5 Performance Flow - L/min


3 P Curves
10 20 30 40 50 60 70 80 90
4 Cartridge only 290 20
CF EF
4 2
3
218 15
Pressure drop - psi

1 2)
Pressure drop - bar
LS 5 PFRS-XX
(or
2 4
3 to
145 rt 10
Po
3 P
1
73 5
A B
2 4 S2
S1
0
SV9-8A 0 5 10 15 20
Flow - USgpm
3 1
P T

A B
S1 2 4 S2

SV9-8B

D-90 3 1 Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


EATON
P T
Model Code PTS9-12

PTS9 – 12 U – *– ***– ***– 00

1 2 3 4 5 6 7

D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
A - Aluminum
Port Port Aluminum Steel
S - Steel 1, 2, 3 & 4 5
2 Size
000 No Body – – –
12 - C12-5S Cavity
12T SAE 12 SAE 4 4998820-002 4998821-002
06G 3/4” BSPP 1/4” BSPP 4998820-004 4998821-004
3 Seals
U - Urethane (standard) 6 Shift Pressure 7 Special features
075 psi (5,2 bar) 00 - None
* These model digits will not be stamped on the valve. 110 psi (7,6 bar) (Only required if valve has
special features, omitted
if “00”)

Dimensions
mm (inch) 1 1/4" HEX
33.3
Torque cartridge in housing (1.31)
A - 81-95 Nm (60-70 ft. lbs)
S - 102-115 Nm (75-85 ft. lbs)
1 1/16"-12 UN-2A

4
86.4
(3.40)

2
Aluminum hous-
ings can be used
1 • for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-91


PTS9-16
Pilot to Shift Valve

Description Operation
The PTS 9-16 is a 3-way, This valve allows flow is directed between
2 position, pilot operated, between ports 3 and 4 ports 3 and 2 while block-
directional screw-in while blocking port 2 until ing port 4. During the
cartridge valve. sufficient pressure has cross-over transition, all
been applied to port 1 and ports are open. The spring
the spring bias is over- chamber for this valve is
come. At that time flow vented to port 5.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 280 bar (4000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
5 1 PTS9-16
Rated inlet flow 151 L/min (40 gpm)
Transition Ports open
3 Temperature range -40° to 100°C (-40° to 210°F)
Cavity C-16-5S
Profile View Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/16/13
CF Standard housing material Aluminum or steel
EF
4 2 Weight cartridge only 0,47 kg (1.05 lbs)
Seal kit (Urethane) 202915-922
LS 5 1
PFRD-XX
5 Performance Flow - L/min
Curves
40 80 120 160
3 P Cartridge only 250 16
4
)
CF EF 200 r2 13
4 2 3 (o
4

Pressure drop - bar


Pressure drop - psi

to
150 3 10
LS 5 1 rt
PFRS-XX Po
2
100 7

3 P
1 50 4
A B
2 4 0
S1 S2 0 5 10 15 20 25 30 35 40 45
Flow - USgpm
SV9-8A

3 1
P T

A B
S1 2 4 S2

SV9-8B
D-92 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
3 1
P T
Model Code PTS9-16

PTS9 – 16 U – *– ***– ***– 00

1 2 3 4 5 6 7

D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
A - Aluminum
Port Port Aluminum Steel
S - Steel 1, 2, 3 & 4 5
2 Size
000 No Body – – –
16 - C16-5S Cavity
16T SAE 16 SAE 4 4994880-002 4994881-002
08G 1” BSPP 1/4” BSPP 4994880-004 4994881-004
3 Seals
U - Urethane (standard) 6 Shift Pressure 7 Special features

030 psi (2 bar) 00 - None


050 psi (3,5 bar) (Only required if valve has
* These model digits will not be stamped on the valve.
070 psi (4,8 bar) special features, omitted
if “00”)

Dimensions
mm(inch) 1.50" HEX
17.8 (.70)
Torque cartridge in housing
A - 108-122 Nm (80-90 ft. lbs)
S - 136-149Nm (100-110 ft. lbs) 1 5/16"-12 UN-2A

4
96.3 (3.79)

Aluminum hous-
2
ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
1 used for operating pressures
above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-93


PTS9-20
Pilot to Shift Valve

Description Operation
The PTS 9-20 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is typically vent-
come. At that time flow is ed to port 5 (tank).

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2
Typical application pressure (all ports) 280 bar (4000 psi)
5 1 Cartridge fatigue
PTS9-16 pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 230 L/min (60 USgpm)
Transition All ports open
3 Internal leakage 3
164 cc/min (10 in /min) @ 3000 PSID
Temperature range -40° to 100°C (-40° to 210°F)
Profile View Cavity C-20-5S
Fluids All general purpose hydraulic fluids such as:
CF EF MIL-H-5606, SAE 10, SAE 20 etc.
4 2 Filtration Cleanliness code 18/16/13
Standard housing material Steel
LS 5 5 1 WeightPFRD-XX
cartridge only 0,86 kg (1.9 lbs)
Seal kit (Urethane) 02-187543
4
3 P Performance Flow - L/min
3
Curves 75 151 227
CF EF 400
Cartridge only
4 2 2 350

LS 5 1 300 21
1 PFRS-XX
250
Delta P psi

Delta P bar
200 14
3 P
150
A B
4
100 7
S1 2 S2
50
SV9-8A
0
0 10 20 30 40 50 60 70
3 1 Flow - GPM
P T P to EF

A B
S1 2 4 S2

SV9-8B

D-94 3 1 Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


EATON
P T
Model Code PTS9-20

PTS9 – 20 U – *– ***– ***– 00

1 2 3 4 5 6 7

D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
A - Aluminum
Port Port Aluminum Steel
S - Steel 1, 2, 3 & 4 5
2 Size 000 No Body – – –
20 - C20-5S Cavity
16T SAE 16 SAE 4 4998822-002 4998823-002
08G 1” BSPP 1/4” BSPP 4998822-004 4998823-004
3 Seals
U - Urethane (standard) 6 Shift Pressure 7 Special features

040 psi (4.3 bar) 00 - None


080 psi (5.2 bar) (Only required if valve has
* These model digits will not be stamped on the valve.
special features, omitted
if “00”)

Dimensions
mm (inch) 20,3 1 7/8" HEX
(.80)
Torque cartridge
in housing
S - 160-180Nm 1 5/8"-12 UN-2A
(120-135 ft. lbs)
A - 130-155 Nm 5
(95-115 ft. lbs)

105,2
(4.14)
3

2
Aluminum hous-
ings can be used
• for pressures up
1 to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-95


Section Overview
Logic elements

This section gives basic The range includes: DIfferential–pressure Flow compensators – PCS3
specifications for Vickers • Pressure compensators sensing elements – DPS2 An essential component of a
logic element and pressure For controlling pressure, pressure compensated flow
compensator threaded car- • Pressure compensators
with priority and bypass flow or direction (including control which, with an exter-
tridge valves. Its purpose is 3- and 4-way bridge cir- nal fixed or variable orifice,
to provide a quick, conven- outlets
cuits) the DPS2 is used provides the required com-
ient reference tool when • Differential–pressure with the aid of external pensated flow characteristic.
choosing these valves or sensing elements pilot operators. The DPS2 Excess flow is diverted at
designing a system using elements are function build- maximum system pressure.
The correct selection of
these components. ing blocks which respond to Excess fluid upstream must
these products can
All cartridges have hard- enhance machine perform- pressure differential signals, be diverted e.g. through a
ened and ground spools, ance, shorten the design providing the capacity to relief to tank.
and/or honed sleeves, process and minimize man- switch or modulate flows Pressure compensator with
poppets and sharp-edged ufacturing costs of manifold up to 303 L/min priority and bypass outlets
ground steel seats. This blocks. (80 USgpm) and pressure –PCS4
provides an excellent prod- to 350 bar (5000 psi).
uct that is dirt-tolerant, has Similar in function to the
The choice of pilot arrange- PCS3. The major difference
reliable seating, and is suit- ments related to DPS2
able for fast cycling with is that excess flow is divert-
variants can minimize the ed at priority flow pressure,
long life. number of construction instead of at maximum sys-
These Vickers cartridges holes in a manifold, tem pressure, as is the
provide the system design- simplifying design and case with PCS3 compen-
er with a versatile range of reducing costs. sators. The excess flow can
elements for use in MCD All poppet type DPS2 pass to a secondary circuit
packages for controlling elements have recently or to tank.
pressure, flow and direction been upgraded to 350 bar
of flow. (5000 psi).
I

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-3


Application
Examples
DPS2 Logic elements for
pressure control

Pressure control
functions Fixed
restrictor
Pressure relief or Pilot pressure
Sequence example source
With external pilot supply and pilot relief

Pilot relief
3 valve
1 2
DPS2-**-P differential
pressure sensing
cartridge

Uni-directional flow

Pressure relief or
Sequence example
With internal pilot supply and pilot relief
Pilot relief
3
valve
1 2
DPS2-**-V dif ferential
pressure sensing
cartridge

Uni-directional flow

Pilot relief
valve
Pressure reducing example
Non-relieving type

3
2 1
DPS2-**-R differential
pressure sensing
cartridge

Uni-directional flow

I-4 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Application
Examples
DPS2 Elements for
pressure control

Accululator charging with Pressure reducing


PUV3-10 pilot stage and relieving

Reduced pressure
sub-circuit
DPS2-**-R
differential DPS2-**-V
pressure differential
sensing pressure
1 cartridge sensing
cartridge Pilot
Relief
DPS2-**-V differential 3 Valve
pressure sensing
cartridge
PUV3-10
2
Full pressure
sub-circuit

Hi/Low unloading circuit Hi/Low unloading circuit


with externally piloted with externally piloted I
pressure sequence pressure sequence
pilot valve pilot valve

2 1

DPS2-**-V
1 differential
pressure sensing
DPS2-**-S differential cartridge
pressure sensing
cartridge 3 2 3

Pilot Pilot
Sequence Sequence
Valve Valve

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-5


Application
Examples
DPS2 Elements for flow
control

Pressure compensated
flow control example
With downstream fixed
or variable restrictor
2 1
DPS2-**-F differential Fixed or
pressure sensing variable
cartridge restrictor

Uni-directional flow

Pressure compensated
priority flow control
example
Fixed or variable priority
With fixed or variable flow restrictor
priority flow control Inlet Priority flow outlet

3
1
DPS2-**-P differential 2
pressure sensing
cartridge

Uni-directional flow

I-6 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Application
Examples
PPS2 Elements for
flow control

Load sensing priority flow


control example
With pressure limiting and
Uni-directional flow
venting
Fixed or
Pump Variable restrictor
Priority outlet, to load

1
Fixed
pilot restrictor
DPS2-**-P differential
pressure sensing
cartridge Venting
pilot
2 3
directional
valve

Pressure limiter
pilot relief valve

Load sensing priority flow


control example
Directional control version I
Uni-directional flow Fixed or
with pressure limiter
variable
restrictors
Directional
Pump control valve
Load service lines

DPS2-**-P differential Pilot


pressure sensing sensing
cartridge checks
2 3

Fixed
pilot restrictor

Pilot
relief
valve

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-7


Application
Examples
PPS2 Elements for
flow control

Load sense circuit


example
For parallel operation Dampening orifice
typ. 0.30 to 0.060

DPS2-**-FF
Hydrostat Dampening orifice
compensator typ. 0.30 to 0.060

Relief valve 80
DPS2-**-FF
pressure limiting psi DPS2-**-FF
Hydrostat 80 Hydrostat
compensator psi compensator
DPS2-**-PF
Relief valve 80 Load sense
pressure limiting psi unloading
DPS2-**-FF
80
160 elelment
Hydrostat
psi
psi compensator
DPS2-**-PF
Load sense
unloading
Load sense bleedelelment
160
Main relief psi
typ. 0.10 GPM

This sub-circuit Dampening orifice


Load0.30
typ. sense
to bleed
0.060
has priority Main relief typ. 0.10 GPM
Load sense circuit
example
DPS2-**-FF
For priority and parallel Hydrostat
Dampening orifice
operation compensator This sub-circuit
has priority typ. 0.30 to 0.060
DPS2-**-FF
Relief valve Hydrostat
pressure limiting compensator
DPS2-**-FF 80
Hydrostat psi
compensator 80 80
psi psi DPS2-**-FF
DPS2-**-PF
Relief valve LoadHydrostat
sense
pressure limiting compensator
unloading
80 elelment
psi
160 80 80
160
psi psi psi
psi DPS2-**-PF
Load sense
unloading
elelment
160 160
Load sense bleed
Main relief psi DPS2-**-PF psi
typ. 0.10 GPM
Note Priority element
1. Pressure limiting relief
must be < main relief
setting. Load sense bleed
Main relief DPS2-**-PF typ. 0.10 GPM
2. If pressure limiting is not Priority element
used; port reliefs set <
main relief are required.

I-8 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Application
Examples
DPS2 Elements for
directional control

Two-way, two-position,
normally open examples
Switched by 3-way, 2-position pilot valve Switched by external pilot pressure and vented
and external pilot pressure through 2-way , 2-position pilot valve
Pilot pressure Fixed
restrictor
source
Pilot
pressure
Pilot source
3 3 Pilot
directional directional
1 2 valve 1 2 valve
DPS2-**-P differential DPS2-**-P differential
pressure sensing cartridge pressure sensing cartridge
Uni-directional flow Uni-directional flow

With DPS2-**-V cartridge and internal pilot supply With DPS2-**-B cartridge and internal pilot supply
& vented through 2-way,2 position pilot valve & vented through 2-way,2 position pilot valve

DPS2-**-V differential DPS2-**-B differential


pressure sensing pressure sensing cartridge
cartridge
Pilot Pilot directional
3 directional valve 3 valve
1
2 2
1

Uni-directional flow
Uni-directional flow

With DPS2-**-S cartridge and internal pilot supply With DPS2-**-T cartridge and internal pilot supply
& vented through 2-way, 2 position pilot valve & swithed by 3-way, 2 position pilot valve and
external pilot pressure

DPS2-**-S differential DPS2-**-T differential


pressure sensing cartridge I
pressure sensing cartridge
Pilot
Pilot directional valve
3
2 3 directional
valve 2
1
1

Bi-directional flow
Uni-directional flow

With DPS2-**-T cartridge and internal With DPS2-**-T cartridge, external pilot supply
shuttle-selected pilot supply and two-way two-position pilot valve
Pilot directional valve Fixed restrictor
DPS2-**-T differential Pilot
pressure sensing cartridge source
Pilot
DPS2-**-T differential directional
3
pressure valve
2 Pilot sensing
1 shuttle cartridge 3
valve
2
1 Bi-directional flow
Bi-directional flow

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-9


Application
Examples
DPS2 Elements for
directional control

Form 1, with DPS2-**-T Form 2, with DPS2-**-P Form 3, with DPS2-**-P

Three-way bridge circuits PA PB


C C C
PA PB PA PB

B A B A B

Example 1, with DPS2-**-T Example 2, with DPS2-**-P Example 3, with DPS2-**-P


Poppet type Spool type Spool type

REQUIRED PILOT AVAILABLE REQUIRED PILOT AVAILABLE


FLOW PATH PRESSURE TO FROM FORM FLOW PATH PRESSURE TO FROM FORM
A B PA PB 1 2 3 PA PB 1 2 3
A B 0 0 Yes AYes BNo 0 1 Yes Yes No
C
C C
1 0 Yes Yes Yes 1 1 Yes Yes Yes

Note 1- Pressure applied 0- Pressure vented


A pressure,
Pilot B A
modified by B
valve
A
P area TBratio (if any), A
P TB A B A B
must exceed load pressure P T
P T P T
at Pvalve in Torder to close
valve.

I-10 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Application
Examples
DPS2 Elements for
directional control

Four-way bridge circuits P2 P3 P2 P3


A B A B

P1 P4 P1 P4
P T
A
A B
B
A B P5 A
A B
B
A
A C B B A B
A C B A
A B
B
ADPS2-**-T
With C
C B A C
C B With DPS2-**-P P T
C C
C
C
Poppet type C Spool type P5
C C

A
A B
B A
A PRESSURE
B B
REQUIRED
A B PILOT
A A
A B
B TO A B
REQUIRED PILOT PRESSURE TO
A
A
FLOW B
P PATH
T
B P1 A AB
PP2 A BT P4B
B A
A B
B
P
P T T A
P P PP3
BT T P5
A B
FLOW
AA
P PATH
T
B P1 P2 P3 P4 P5
A
P
A
B
T
B A
AP
P
P1B
A BT
T T
T 1 P
P BT
T
P T 1 P1 P
P T 1BT
T
A
P
P
BT
T 1 1 0 1 1
P T P T
P T P PT T P T
0 0 0 0 0 0 1 1 1 1

1 1 0 0 0 0 1 0 1 1

0 0 1 1 0 1 0 1 0 1

1 1 1 1 0 1 1 1 0 1

1 0 0 1 1 1 0 1 1 1
I

0 1 1 0 1

1-Pressure applied 0-Pressure vented

Note
Pilot pressure, modified by
valve area ratio (if any),
must exceed load pressure
at valve in order to close
valve.

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-11


DPS2-10
Differential pressure
sensing valve

Description Operation
The DPS2-10 is a This valve is used as a either directional control,
differential pressure main section of a pilot flow control or pressure
sensing valve, available controlled valve assembly. control cartridges. Refer to
as either a spool or This valve has multiple application examples.
poppet type and with uses when used with
either, internal or external
pilot.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (spool type) 290 bar (4200 psi)
(poppet type) 350 bar (5000 psi)**
Rated flow 60 L/min (15 USgpm)
Functional Symbols
Pilot ratio (spool type P,V,R,F) 1:1
See pages I-20 & I-21 (poppet type B,S,T) 2:1
Internal leakage, poppet type Port 1 to 2: < 5 drops/min max @ 350 bar (5000 psi)
Internal leakage, spool type 82 cm 3/min. (5 in 3/min) max @ 290 bar (4200 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-10-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 14 kg (0.30 lbs)
Profile View Seal kits 889650 Buna-N
889652 Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves B/S/T models


Cartridge only P/V models
F/R models
Flow - L/min (21,8 cSt oil @ 49° C)
0 10 20 30 40 50 60
250
16

200 14
3
Pressure drop - bar
Pressure drop - psi

12
150 10

8
2 100
6

50 4
1
2
0 0
0 2 4 6 8 10 12 1 6
Flow - USgpm (105 SUS oil @ 120° F)

I-12 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code DPS2-10

DPS2 – 10 (V) – * – * – ** – *** – **

1 2 3 4 5 6 7 8

1 Function P – Spool, N/C (L/S element) 5 Adjustment 7 Differential pressure


V – Spool, N/C
DPS2 – Differential pressure
R – Spool, pressure
F – None 5– 0,35 bar (5 psi)+ I
sensing S – Stroke adjustment 10 – 0,7 bar (10 psi)+ I
reducing, N/O
F – Spool, flow control, N/O “S” adjustment is not available 20 – 1,40 bar (20 psi)+ I
2 Size with F and R functions. 40 – 2,80 bar (40 psi)
(hydrostat)
10 – 10 Size 80 – 5,50 bar (80 psi)
6 Port size 160 – 11,0 bar (160 psi)
3 Seals
0 – Cartridge only + Not available with the “B”,
Blank – Buna-N
V – Viton CODE PORT SIZE HOUSING NUMBER "S" and “T” poppet.
I The operating back
Aluminum
4 Function pressure at port 3 should
3B 3/8” BSPP 02–175470*
B – Poppet, vent to open, never be less than 1.3 times
6T SAE 6 566413* the spring set pressure.
N/C
S – Poppet, vent to open, 6H SAE 6 876706
8 Special features
N/C 8H SAE 8 876712
T – Poppet, bi-directional, 2G 1/4” BSPP 876707 00 - No special features
pilot to close, 2:1 ratio, 3G 3/8” BSPP 876710
N/C
* Light duty housing
See section J for housing details.

Dimensions
mm (inch)
I

Torque cartridge
in housing
A – 47-54 Nm (35-40 ft. lbs)
S – 68-70 Nm (50-55 ft. lbs)

Aluminum hous-
ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-13


DPS2-12
Differential pressure
sensing valve

Description Operation
The DPS2-12 is a This valve is used as a either directional control,
differential pressure main section of a pilot flow control or pressure
sensing valve, available controlled valve assembly. control cartridges. Refer to
as a spool type with either, This valve has multiple application examples.
internal or external pilot. uses when used with

RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (spool type) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Functional Symbols Pilot ratio (spool type P,V,R,F) 1:1
(poppet type B,S,T) 1:2
See pages I-20 & I-21 Internal leakage, spool type 82 cm 3/min. (5 in 3/min) max @ 350 bar (5000 psi)
poppet type B,S,T Less than 5 drops/min @ 3000 psi
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-12-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 31 kg (0.68 lbs)
Seal kits Buna-N
Profile View Viton®
Viton is a registered trademark of E.I. DuPont

Pressure Drop Curves B / S / T model


Cartridge only P / V model
Flow - L/min F / R model
0 19 38 60 76 95 114
250 17.2

200 13.8
Pressure drop 1 to 2 in bar
Pressure Drop 1 to 2 in psi

150 10.3
3

100 6.8

2
50 3.4

1 0 0
0 5 10 15 20 25 30
Flow (GPM)

I-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code DPS2-12

DPS2 – 12 (V) – * – F – ** – *** – **

1 2 3 4 5 6 7 8

1 Function 5 Adjustment 7 Differential pressure

DPS2 – Differential pressure F – None 040 – 2,80 bar (40 psi)


sensing 080 – 5,50 bar (80 psi)
6 Port size 160 – 11,0 bar (160 psi)
2 Size 0 – Cartridge only
8 Special features
12 – 12 Size
CODE HOUSING NUMBER PORTS 1 & 2 PORT 3 00 - No special features
3 Seals (A)10T 02–178268 SAE-10 SAE-6
Blank – Buna-N (A)12T 02–178269 SAE-12 SAE-6
V – Viton (A)4G 02–178270 1/2” BSPP 3/8” BSPP
4 Function (A)6G 02–178271 3/4” BSPP 3/8” BSPP
B – Poppet, vent to open, (S)10T 02–160996 SAE-10 SAE-6
N/C (S)12T 02–160997 SAE-12 SAE-6
S – Poppet, vent to open, (S)4G 02–160994 1/2” BSPP 3/8” BSPP
N/C
(S)6G 02–160995 3/4” BSPP 3/8” BSPP
T – Poppet, bidirectional,
pilot to close, 2:1 ratio See section J for housing details.
N/C
P – Spool, N/C (L/S element)
V – Spool, N/C
R – Spool, pressure
reducing, N/O I
F – Spool, flow control, N/O
(hydrostat)
34,5 (1.36)

Dimensions
mm (inch)

Torque cartridge
in housing
A – 81-95 Nm (60-70 ft. lbs)
S – 102-115 Nm (75-85 ft. lbs) 1.063 - 12 Thd.

38,2 (2.29)

Aluminum hous-
ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
22,2 (0.873) used for operating pressures
above 210 bar (3000 psi).
23,7 (0.935)

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-15


DPS2-16
Differential pressure
sensing valve

Description Operation
The DPS2-16 is a This valve is used as a main This valve has multiple flow control or pressure
differential pressure section of a pilot controlled uses when used with control cartridges. Refer to
sensing valve, available valve assembly. either directional control, application examples.
as either a spool or
poppet type and with RATINGS AND SPECIFICATIONS
either, internal or external Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
pilot. Typical application pressure (spool type) 290 bar (4200 psi)
(poppet type) 210 bar (3000 psi) or 350 bar (5000 psi)**
Rated flow 189 L/min (50 USgpm)
Pilot ratio (spool type P,V,R,F) 1:1
(poppet type B,S,T) 2:1
Functional Symbols Internal leakage, poppet type Port 1 to 2: < 5 drops/min. max @ 350 bar (5000 psi)
See pages I-20 & I-21 Internal leakage, spool type 82 cm 3/min. (5 in 3/min) max @ 290 bar (4200 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-16-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 35 kg (0.78 lbs)
Seal kits 889659 Buna-N
02-165871 Viton®
Viton is a registered trademark of E.I. DuPont
Profile View

Pressure Drop Curves B/S/T models


Cartridge only P/V models
F/R models
Flow - L/min (21,8 cSt oil @ 49° C)
0 20 40 60 80 100 120 140 160 180
250
16

200 14
Pressure drop - bar
Pressure drop - psi

3
12
150 10

8
100
2 6
4
50
1 2
0
0 10 20 30 40 50
Flow - USgpm (105 SUS oil @ 120° F)

I-16 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code DPS2-16

DPS2 – 16 (V) – * – * – ** – *** – **

1 2 3 4 5 6 7 8

1 Function P – Spool, N/C (L/S element) 5 Stroke adjustment 7 Differential pressure


V – Spool, N/C
DPS2 – Differential pressure
R – Spool, pressure
F – None 5– 0,35 bar (5 psi)+ I
sensing S – Stroke adjustment 20 – 1,40 bar (20 psi)+ I
reducing, N/O
F – Spool, flow control, N/O “S” adjustment is not available 40 – 2,80 bar (40 psi)
2 Size with F and R functions. 80 – 5,50 bar (80 psi)
(hydrostat)
16 – 16 Size 160 – 11,0 bar (160 psi)
6 Port size
3 Seals + Not available with the “B”
0 – Cartridge only and “S”, “T” poppet
Blank – Buna-N
CODE PORT SIZE HOUSING NUMBER I The operating back
V – Viton
Aluminum pressure at port 3 should
4 Function never be less than 1.3 times
4B 3/4” BSPP 02-175471* the spring set pressure
B – Poppet, vent to open, 12T SAE 12 566414*
N/C 8 Special features
S – Poppet, vent to open, 10H SAE 10 876725
N/C 12H SAE 12 876727 00 - 210 bar (3000 psi) rated
T – Poppet, bi-directional, valve
4G 1/2” BSPP 02-160676
pilot to close, 2:1 ratio, AA - 350 bar (5000 psi) rated
6G 3/4” BSPP 876726
N/C valve (poppet type only) (Only
* Light duty housing required if valve has special
See section J for housing details. features, omit if 00)**
Dimensions
mm (inch)
“S” Adjustment I
4,8 (0.19) hex

Torque cartridge “F” Adjustment


in housing
A – 108-122 38,1 (1.50) hex
56,3 Torque 108-122 Nm
Nm (80-90 ft. lbs)
(2.22) Max (80-90 ft. lbs)
S – 136-149 32,1
Nm (100-110 ft. lbs) (1.27) Max

1.312 -12 Thd.


3

55,6
(2.18)
Aluminum hous-
2 ings can be used
• for pressures up
to 210 bar (3000
1 psi). Steel housings must be
25,37 (0.999)
used for operating pressures
28,50 (1.122) above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-17


DPS2-20
Differential pressure
sensing valve

Description Operation
The DPS2-20 is a This valve is used as a This valve has multiple flow control or pressure
differential pressure main section of a pilot uses when used with control cartridges. Refer to
sensing valve, available controlled valve assembly. either directional control, application examples.
as either a spool or
poppet type and with RATINGS AND SPECIFICATIONS
either, internal or external Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
pilot. Typical application pressure (spool type) 290 bar (4200 psi)
(poppet type) 210 bar (3000 psi) or 350 bar (5000 psi)**
Rated flow 303 L/min (80 USgpm)
Pilot ratio (spool type P,V,R,F) 1:1
(poppet type B,S,T) 2:1
Functional Symbols Internal leakage, poppet type Port 1 to 2: < 5 drops/min max @ 350 bar (5000 psi)
See pages I-20 & I-21 Internal leakage, spool type 82 cm 3/min (5 in 3/min) max @ 290 bar (4200 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-20-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 81 kg (1.78 lbs)
Seal kits 02-113153 Buna-N
02-112969 Viton®
Viton is a registered trademark of E.I. DuPont
Profile View

Pressure Drop Curves B/S/T models


Cartridge only P/V models
F/R models
Flow - L/min (21,8 cSt oil @ 49° C)
0 40 80 120 160 200 240 280
250
16
200 14
Pressure drop - psi

Pressure drop - bar

3 12
150
10
8
100
2 6

50 4

1 2
0 0
0 10 20 30 40 50 60 70 80
Flow - USgpm (105 SUS oil @ 120° F)

I-18 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


Model Code DPS2-20

DPS2 – 20 (V) – * – * – ** – *** – **

1 2 3 4 5 6 7 8

1 Function P – Spool, N/C (L/S element) 5Stroke adjustment 7 Differential pressure


V – Spool, N/C
DPS2 – Differential pressure
R – Spool, pressure
F – None (Fixed stroke) 5– 0,35 bar (5 psi)+ I
sensing S – Screw adjustment 10 – 0,7 bar (10 psi)+ I
reducing, N/O
F – Spool, flow control, N/O
Screw adjustment is not available 20 – 1,40 bar (20 psi)+ I
2 Size with F and R functions.
40 – 2,80 bar (40 psi)
(hydrostat)
20 – 20 Size 80 – 5,50 bar (80 psi)
6 Port size 160 – 11,0 bar (160 psi)
3 Seals
0 – Cartridge only + Not available with the “B”
Blank – Buna-N
V – Viton CODE PORT SIZE HOUSING NUMBER and “S”, “T” poppet
I The operating back
Aluminum
4 Function pressure at port 3 should
8B 1” BSPP 02-175472*
B – Poppet, vent to open, never be less than 1.3 times
16T SAE 16 566415* the spring set pressure
N/C
S – Poppet, vent to open, 12H SAE 12 876741
8 Special features
N/C 16H SAE 16 876743
T – Poppet, bi-directional, 6G 3/4” BSPP 876740 00 - 210 bar (3000 psi) rated
pilot to close, 2:1 ratio, valve
8G 1” BSPP 876742 AA - 350 bar (5000 psi) rated
N/C
* Light duty housing valve (poppet type only) (Only
See section J for housing details. required if valve has special
features, omit if 00)**
Dimensions
mm(inch) “S” Adjustment I
4,8 (0.19) hex

Torque cartridge “F” Adjustment


in housing
47,6 (1.87) hex
A – 128-155
62,1 Torque 129-156 Nm
Nm (95-115 ft. lbs)
(2.44) Max (95-115 ft. lbs)
S – 163-183 34,0
Nm (120-135 ft. lbs) (1.34) Max

Note 1.625 -12 Thd.


For application at 350 bar 3
(5000 psi) torque into steel
housing to 205 - 218 Nm
(150 - 160 ft. lbs) (for valves 76,2
with “AA” special feature (3.00)
only) Aluminum hous-
2 ings can be used
• for pressures up
to 210 bar (3000
1 psi). Steel housings must be
33,30 (1.311)
used for operating pressures
36,47 (1.436) above 210 bar (3000 psi).

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-19


DPS2
Spool type functional
symbols

DPS2-**-P-S DPS2-**-P-F DPS2-**-V-S DPS2-**-V-F


1 1 1 1

2 3 2 3 2 3 2 3

DPS2-**-F-F DPS2-**-R-F

2 2 3

1 3 1

I-20 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007


DPS2
Poppet type functional
symbols

DPS2-**-B-S DPS2-**-B-F DPS2-**-S-S DPS2-**-S-F


1 1 2 2

2 3 2 3 1 3 1 3

DPS2-**-T-S DPS2-**-T-F
1 1 I

2 3 2 3

EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 I-21


Eaton Eaton Eaton
Hydraulics Operations USA Hydraulics Operations Europe Hydraulics Operations Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 11th Floor Hong Kong New World Tower
Eden Prairie, MN 55344 1110 Morges 300 Huaihai Zhong Road
USA Switzerland Shanghai 200021
Tel: 952-937-9800 Tel: +41 (0) 21-811-4600 China
Fax: 952-294-7722 Fax: +41 (0) 21-811-4601 Tel: 86-21-6387-9988
www.hydraulics.eaton.com Fax: 86-21-6335-3912

© 2005 Eaton Corporation


All Rights Reserved
Printed in USA
Document No. V-VLSC-MC003-E
December 2008

Vous aimerez peut-être aussi