Académique Documents
Professionnel Documents
Culture Documents
Vickers Screw-in
Cartridge Valves
Solenoid Valves
Ø
Valve locator
2-way, 2-position
normally closed
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated
(restricted reverse flow when energized) L/min (USgpm) bar (psi)
SV11-10-C/CM* C-10-2 45 (12) 350 (5000) A-16
SV12-10-C/CM* C-10-2 23 (6) 350 (5000) A-22
2
FLOW TYPICAL
1 MODEL CAVITY RATING PRESSURE PAGE
Spool type, direct acting L/min (USgpm) bar (psi)
SV14-8-C/CM* C-8-2 11 (3) 350 (5000) A-44
2
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Poppet type, pilot operated L/min (USgpm) bar (psi)
1
SV13-10-C/CM* C-10-2 45 (12) 350 (5000) A-26
SV3-12-C/CM*/CR* C-12-2 114 (30) 210 (3000) A-28
C-12-2-U
2 SV2-20-C/CM*/CR*† C-20-2 227 (60) 210 (3000) A-38
Bi-directional, 2-way,
2-position normally closed
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated
SBV11-10-C C-10-2 76 (20) 350 (5000) A-18
2-way, 2-position
normally open
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated L/min (USgpm) bar (psi)
SV15-10-O/OP*/OS* C-10-2 45 (12) 350 (5000) A-62
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
1 Spool type, direct acting L/min (USgpm) bar (psi)
SV14-8-O/OM* C-8-2 13 (4) 350 (5000) A-82
SV14-10-O/OM* C-10-2 23 (6) 350 (5000) A-86
2
†Explosion proof, CSA Approved, coil option available (see page C-11)
*M = Manual override, *P = Push type manual override, *S = Screw type manual override, *R = Pull type manual override
2-way, 2-position
normally open
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
Poppet type, pilot operated L/min (USgpm) bar (psi)
SV13-10-O/OP*/OS* C-10-2 45 (12) 350 (5000) A-58
SV3-12-O/OP*/OS* C-12-2 114 (30) 210 (3000) A-66
1 C-12-2U
SV13-16-O/OP*/OS* C-16-2 132 (35) 350 (5000) A-74
SV3-20-O/OP*/OS*† C-20-2 227 (60) 210 (3000) A-76
2 SV13-20-O/OP*/OS* C-20-2 227 (60) 350 (5000) A-78
Bi-directional, 2-way,
2-position normally open
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
1 Poppet type, pilot operated L/min (USgpm) bar (psi)
SBV11-8-O C-8-2 60 (15) 350 (5000) A-54
SBV11-10-O C-10-2 76 (20) 350 (5000) A-64
2
3-way, 2-position
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 Spool type, direct acting L/min (USgpm) bar (psi)
SV11-8-3/3M* C-8-3 11 (3) 350 (5000) A-90
SV11-10-3/3M* C-10-3 23 (6) 350 (3000) A-96
3 1 SV1A/B-12-3P C-12-3 42 (11) 210 (3000) A-100
c
Flow port 1 to port 2 not to exceed 10 L/min (2.5 USgpm)
FLOW TYPICAL
2 MODEL CAVITY RATING PRESSURE PAGE
Spool type, direct acting L/min (USgpm) bar (psi)
SV2A/B-12-3P C-12-3 38 (10) 210 (3000) A-102
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2
Spool type L/min (USgpm) bar (psi)
SV4A/B-12-3P C-12-3 42 (11) 210 (3000) A-104
C
Port 1 must be vented to tank. Tank pressure not to exceed 13,7 bar (200 psi)
3 1
†Explosion proof, CSA Approved, coil option available (see page C-11)
*M = Manual override, *P = Push type manual override, *S = Screw type manual override, *R = Pull type manual override
4-way, 2-position
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
2 4 Spool type, direct acting L/min (USgpm) bar (psi)
SV11-8-4/4M* C-8-4 11 (3) 350 (5000) A-108
SV11-10-4/4M* C-10-4 23 (6) 350 (5000) A-116
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2 4 Spool type, direct acting L/min (USgpm) bar (psi)
SV12-8-4/4M* C-8-4 13 (4) 350 (5000) A-112
SV2A/B-12-4P C-12-4 53 (14) 210 (3000) A-128
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2 4 Spool type L/min (USgpm) bar (psi)
SV3-10-4/4M*/4R*† C-10-4 23 (6) 210 (3000) A-120
SV3A/B-12-4P C-12-4 53 (14) 210 (3000) A-130
3 1
2 4 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Spool type, selector valve L/min (USgpm) bar (psi)
SV4-10-4/4M*/4R*† C-10-4 23 (6) 210 (3000) A-122
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Spool type, selector valve L/min (USgpm) bar (psi)
SV5-10-4/4M*/4R* C-10-4 23 (6) 210 (3000) A-124
3 1 SV5A/B-12-4P C-12-4 53 (14) 210 (3000) A-132
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Spool type L/min (USgpm) bar (psi)
SV7A/B-12-4P C-12-4 46 (12) 210 (3000) A-134
3 1
†Explosion proof, CSA Approved, coil option available (see page C-11)
*M = Manual override, *P = Push type manual override, *S = Screw type manual override, *R = Pull type manual override
Manually operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 Pull-to-open, 2-way, 2 position L/min (USgpm) bar (psi)
MPV1-10 C-10-2 45 (12) 210 (3000)* D-38
MPV3-10 (detent) C-10-2 45 (12) 210 (3000)* D-40
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 3 Manual rotary, 3-position detent L/min (USgpm) bar (psi)
MRV3-10-D/E C-10-3 23 (6) 210 (3000)* D-4
MRV3-16-D C-16-3 64 (17) 210 (3000)* D-6
1
FLOW TYPICAL
2 MODEL CAVITY RATING PRESSURE PAGE
Push-to-open, 3-way, 2 position L/min (USgpm) bar (psi)
MSV1-12 C-12-3 42 (11) 210 (3000) D-42
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2
Push-to-open, 3-way, 2 position L/min (USgpm) bar (psi)
MSV2-12 C-12-3 38 (10) 210 (3000) D-44
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2
Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV3-12 C-12-4 53 (14) 210 (3000) D-48
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2 Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV4-12 C-12-4 53 (14) 210 (3000) D-50
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2
Push-to-open, 3-way, 2 position L/min (USgpm) bar (psi)
MSV5-12 C-12-3 42 (11) 210 (3000) D-46
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV6-12 C-12-4 53 (14) 210 (3000) D-52
3 1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4 Push-to-open, 4-way, 2 position L/min (USgpm) bar (psi)
MSV7-12 C-12-4 45 (12) 210 (3000) D-54
3 1 FLOW TYPICAL
MODE CAVITY RATING PRESSURE PAGE
2 4
Manual lever, 4-way, 3 position L/min (USgpm) bar (psi)
MLV9-12-A C-12-4 60 (15) 210 (3000) D-32
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 4
Manual lever, 4-way, 3 position L/min (USgpm) bar (psi)
MLV9-12-E C-12-4 60 (15) 210 (3000) D-34
3 1
Manually operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
Manual rotary, 4-way, 3-position detented L/min (USgpm) bar (psi)
4 2
MRV5-10-D/E C-10-4 11 (3) 210 (3000) D-12
MRV5-16-D C-16-4 45 (12) 210 (3000) D-14
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2
Manual rotary, 4-way, 3-position detented L/min (USgpm) bar (psi)
MRV6-10-D/E C-10-4 11 (3) 210 (3000) D-16
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Manual rotary, 4-way, 3-position detented L/min (USgpm) bar (psi)
4 2
MRV4-10-D/E C-10-4 11 (3) 210 (3000) D-8
MRV4-16-D C-16-4 45 (12) 210 (3000) D-10
* Indicates that these models are available for use above 210 bar (3000 psi). However, caution should be taken and a review of the
3 1 application may be necessary prior to use. Contact your Eaton sales engineer.
Pilot operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
External pilot, atmospheric vent, 3 way, 2 position L/min (USgpm) bar (psi)
3
1 PTS1-10 C-10-4 30 (8) 210 (3000) D-56
PTS1-16 C-16-4 132 (35) 210 (3000) D-58
2 4 PTS1-20 C-20-4 265 (70) 210 (3000) D-60
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
3 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
1
PTS2-16 C-16-4 132 (35) 210 (3000) D-64
PTS2-20 C-20-4 265 (70) 210 (3000) D-66
2 4
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
3 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
1 PTS3-16 C-16-4 132 (35) 210 (3000) D-70
PTS3-20 C-20-4 265 (70) 210 (3000) D-72
2
4
Pilot operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
2 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
4
PTS5-10 C-10-3 11 (3) 210 (3000) D-76
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
3
External pilot, atmospheric vent, 3 way, 2 position L/min (USgpm) bar (psi)
1
PTS5-16 C-16-4 132 (35) 210 (3000) D-78
2 4
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
2
4 External pilot, internal drain, 3 way, 2 position L/min (USgpm) bar (psi)
PTS6-16 C-16-4 132 (35) 210 (3000) D-82
3 1
FLOW TYPICAL
MODEL CAVITY RATING PRESSUREPAGE
Dual External pilot, 3 way, 2 position L/min (USgpm) bar (psi)
4 2 PTS9-8 C-8-5S 19 (5) 280 (4000) D-86
5 1 PTS9-10 C-10-5S 38 (10) 280 (4000) D-88
PTS9-12 C-12-5S 76 (20) 280 (4000) D-90
3 PTS9-16 C-16-5S 151 (40) 280 (4000) D-92
PTS9-20 C-20-5S 228 (60) 280 (4000) D-94
Manually operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Electrohydraulic pressure
reducing/relieving
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
RP Internal pilot, spool type L/min (USgpm) bar (psi)
EPRV1-16 C-16-3 38 (10) 35 (500) B-60
P T
Electrohydraulic
Proportional Relief
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2-stage, pilot operated L/min (USgpm) bar (psi)
ERV1-10 C-10-2 4-57 (1-15) 210 (3000) B-50
1 ERV1-16 C-16-2 8-132 (2-35) 210 (3000) B-52
2
Electrohydraulic Flow
Regulator
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Promotional, 2-way, normally closed popet type
ESV1-8*-C C-8-2 71 (19) 210 (3000) B-18
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
2 Nose in, side out L/min (USgpm) bar (psi)
EPV16-A C-16-3S (modified) 0-160 (0-42) 280 (4000) B-10
1 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
3 1 Side in, nose out L/min (USgpm) bar (psi)
EPV16-B C-16-3S (modified) 0-160 (0-42) 280 (4000) B-10
2 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
3
Direct acting L/min (USgpm) bar (psi)
EFV1-10*-C C-10-3 38 (10) 210 (3000) B-31
1
EFV1-12*-C C-12-3 77 (20) 210 (3000) B-37
2
FLOW TYPICAL
1 MODEL CAVITY RATING PRESSURE PAGE
L/min (USgpm) bar (psi)
EFV2-12*-C C-12-3 114 (30) 210 (3000) B-43
FLOW TYPICAL
2 3 MODEL CAVITY RATING PRESSURE PAGE
2 Direct acting L/min (USgpm) bar (psi)
EFV1-10*-O C-10-3 38 (10) 210 (3000) B-28
EFV1-12*-O C-12-3 104 (27.5) 210 (3000) B-34
1
3
FLOW TYPICAL
1 MODEL CAVITY RATING PRESSURE PAGE
Side in, nose out L/min (USgpm) bar (psi)
EFV2-12*-0 C-12-3 114 (30) 210 (3000) B-40
2 3 FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Promotional, 2-way, normally open popet type
ESV1-8*-O C-8-2 60 (16) 210 (3000) B-16
ESV1-10*-O C-10-2 98 (26) 210 (3000) B-20
ESV1-12*-O C-12-2 128 (34) 210 (3000) B-24
Pressure reducing/relieving
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Pilot operated
PRV2-16 C-16-3 151 (40) 350 (5000) E-48
3
2 1
Relief valves
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
Poppet, differential area L/min (USgpm) bar (psi)
2 1 RV3-10 C-10-2 76 (20) 250 (3600) E-14
FLOW TYPICAL
1 2 MODEL CAVITY RATING PRESSUREPAGE
Poppet type, direct acting, thermal relief check valve L/min (USgpm) bar (psi)
RV4-10 C-10-2 45 (12) 350 (5000) E-22
Flow restrictors,
knob/lever operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Manual rotary L/min (USgpm) bar (psi)
MRV2-10-K C-10-2 60 (15) 210 (3000) F-38
1 2 MRV2-10-B/E/D/L C-10-2 60 (15) 210 (3000) F-38
MRV2-16-K C-16-2 170 (45) 210 (3000) F-40
MRV2-16-B/E/D/L C-16-2 170 (45) 210 (3000) F-40
Flow restrictors,
adjustable
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Needle valve L/min (USgpm) bar (psi)
1 2 NV1-10 C-10-2 45 (12) 210 (3000) F-44
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Needle valve, restricted reverse flow L/min (USgpm) bar (psi)
1 2
NV1-16 C-16-2 151 (40) 210 (3000) F-46
NV1-20 C-20-2 265 (70) 210 (3000) F-48
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Needle type L/min (USgpm) bar (psi)
FCV11-12 C-12-2 114 (30) 350 (5000) F-52
1 2 C-12-2U
FCV6-16 C-16-2 208 (55) 210 (3000) F-54
Flow regulators
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 (pressure compensated) Two way, pre-set flow L/min (USgpm) bar (psi)
FR5-8 C-8-2 10 (2.5) 350 (5000) F-4
FR1-16 C-16-2 113 (30) 210 (3000) F-8
FR1-20 C-20-2 227 (60) 210 (3000) F-10
1
FLOW TYPICAL
2 MODEL CAVITY RATING PRESSURE PAGE
(pressure compensated) Two-way, adjustable flow regulator L/min (USgpm) bar (psi)
FR2-16 C-16-2 113 (30) 210 (3000) F-14
1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Pressure compensated flow regulator L/min (USgpm) bar (psi)
FAR1-10 C-10-2 1 - 38 (25 - 10) 350 (5000) F-16
1 2 FAR1-12 C-12-2 1,5 - 94,5 (0,44 - 25) 350 (5000) F-18
C-12-2U
FAR1-16 C-16-2 3,8 - 15,1 (1.0-4.0) 350 (5000) F-20
MAX MAX
REG. INLET TYPICAL
1 3 MODEL CAVITY FLOW FLOW PRESSURE PAGE
3-way priority flow regulator L/min (USgpm) bar (psi)
50% adjustable
2 PFR2-16 C-16-3 114 (30) 151 (40) 210 (3000) F-30
CF EF
4 2
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
LS 5 1
Dynamic Signal (PFRD) L/min (USgpm) bar (psi)
PFRD-12 C-12-5S 76 (20) 280 (4000) F-32
3 P PFRD-16 C-16-5S 150 (40) 280 (4000) F-34
PFRD-20 C-20-5S 230 (60) 240 (3500) F-36
CF EF Static Signal (PFRS)
4 2
PFRS-12 C-12-5S 76 (20) 280 (4000) F-32
LS 5 1 PFRS-16 C-16-5S 150 (40) 280 (4000) F-34
PFRS-20 C-20-5S 230 (60) 240 (3500) F-36
3 P
Flow dividers
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSURE PAGE
2 4 Flow divider/combiner L/min (USgpm) bar (psi)
FDC1-20 manifold 378 (100) 210 (3000) F-70
3
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
4 2 Posi-trachon valve L/min (USgpm) bar (psi)
FDC3-20 manifold 567 (150) 210 (3000) F-80
Direct operated
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Direct acting, poppet type L/min (USgpm) bar (psi)
CV3-4 C-4-2 8 (2) 350 (5000) G-4
2 1 CV11-12 C-12-2, C-12-2U 114 (30) 350 (5000) G-14
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
1 2 Direct acting, poppet type L/min (USgpm) bar (psi)
CV16-10 C-10-2 76 (20) 350 (5000) G-12
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
1 2 Direct acting, poppet type with orifice L/min (USgpm) bar (psi)
CV6-10 C-10-2 76 (20) 350 (5000) G-20
CV6-16 C-16-2 151 (40) 210 (3000) G-22
Differential pressure
FLOW TYPICAL
sensing MODEL CAVITY RATING PRESSURE PAGE
Differential pressure sensing, spool type L/min (USgpm) bar (psi)
DPS2-10 C-10-3S 57 (15) 240 (3500)* I-12
DPS2-12 C-12-3S 114 (30) 240 (3500)* I-14
DPS2-16 C-16-3S 190 (50) 240 (3500)* I-16
DPS2-20 C-20-3S 303 (80) 240 (3500)* I-18
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Differential pressure sensing, poppet type L/min (USgpm) bar (psi)
DPS2-10 C-10-3S 57 (15) 350 (5000) I-12
DPS2-16 C-16-3S 190 (50) 350 (5000) I-16
DPS2-20 C-20-3S 303 (80) 350 (5000) I-18
Functional Symbols * Indicates that these models are available for use above 240 bar (3500 psi). However, caution should be taken and a review of the
Spool type application may be necessary prior to use. Contact your Eaton applications engineer.
2 1 2 3 1
1 3 2 3 1 2 3
DPS2-**-F DPS2-**-P DPS2-**-R DPS2-**-V
Spool, flow control, Spool, Spool, pressure reducing, Spool, normally
normally open normally closed normally open closed
Poppet type
1 2
1
2 3
2 3 1 3
DPS2-**-B DPS2-**-S DPS2-**-T
Poppet, vent to open, Poppet, vent to open, Poppet, bi-directional pilot to close, 2:1 ratio,
normally closed normally closed normally closed
Pressure compensators,
restrictive
FLOW TYPICAL
Functional Symbol MODEL CAVITY RATING PRESSUREPAGE
Compensator spool element, restrictive type L/min (USgpm) bar (psi)
PCS3-12 C-12-3 58 (15) 210 (3000) I-24
3 2 PCS3-16 C-16-3 114 (30) 210 (3000) I-26
PCS3-20 C-20-3 189 (50) 210 (3000) I-28
1
FLOW TYPICAL
MODEL CAVITY RATING PRESSURE PAGE
Compensator spool element, priority type L/min (USgpm) bar (psi)
PCS4-10 C-10-4 38 (10) 210 (3000) I-30
4 3 PCS4-12 C-12-4 58 (15) 210 (3000) I-32
PCS4-16 C-16-4 114 (30) 210 (3000) I-34
1 2 PCS4-20 C-20-4 189 (50) 210 (3000) I-36
This section gives basic • Pilot operated poppet Reducing Valves Accumulator Unloading
specifications for Vickers type with reverse free- Two types are available: Valves
pressure control threaded flow check – RV2 Valves that allow accumula-
cartridge valves. Its pur- • Direct operated with
Use as a service line relieving feature – PRV1 tors to be charged to a pre-
pose is to provide a quick, relief where anticavita- selected maximum pres-
convenient reference tool tion make-up is required. • Pilot operated with sure at which the pump is
when choosing Vickers car- It may also be applied as relieving feature – PRV2 unloaded. The pump does
tridge valves or designing a an internally piloted and PRV12 not cut-in until the accumu-
system using these compo- counterbalance valve in a lator pressure has decayed
nents. • Pilot operated without
service line. relieving feature to a pre-selected percent-
Eaton offers a full range • Direct operated poppet age of maximum pressure.
of Vickers direct and pilot type, differential area Sequence Valves The low-flow PUV3 model
operated relief, reducing, models – RV3 and RV8 can be used as a stand E
sequence and unloading A complete range of alone model for low flow
valves. In general, the Sometimes termed a sequence functions is applications, or as a pilot
direct operated products “differential area relief available, including: stage in two-stage arrange-
are faster in response while valve”. A fast acting valve, • Normally-closed and ments for higher flows.
pilot operated types have highly tolerant of contam- normally-open models
a flatter pressure/flow inant and providing an Accumulator Discharge
alternative flow path, • Internal and external
characteristic. pilot options Valve
frequently beneficial in
This valve is designed to
Relief Valves manifold layout. Utilized • Internal and external
ensure that an accumulator
in CRV3 cross-line drain options
When selecting a relief will discharge when pilot
relief packages. • Two and three
valve for a specific applica- pressure is lost, e.g. on
tion, consideration should • Pilot operated spool position models pump shutdown.
be given to the following type – RV5 and RV11 Externally drained models
• Direct operated poppet Well suited for repetitive, may be used as relief Fluid Cleanliness
types – RV1 and RV10 continuous duty with a valves in circuits with alter- Proper fluid condition
low pressure-override nating pressure and tank is essential for long and
Suitable for continuous characteristic. line functions.
duty with reliable fast satisfactory life of hydraulic
response, the RV10 • Direct operated ball components and systems.
being a low pressure, type – RV6 Hydraulic fluid must have
low cost option. These A fast-acting valve for the correct balance of
valves are also suitable intermittent duty. This cleanliness, materials, and
for piloting the DPS2 low flow, low cost valve additives for protection
logic elements. may be used as a pilot against wear of compo-
section for a larger main- nents, elevated viscosity,
stage valve, or piloting and inclusion of air.
logic elements.
Description Operation
The RV4-10-F is a direct act- This valve has a dual func- is overcome at port 1. The The valve remains closed
ing, poppet type, screw-in tion. In the first function poppet is unseated and until the predetermined set-
cartridge type thermal relief the valve acts as a check allows flow from port 1 to ting is reached. The valve
with reverse flow check valve and remains closed port 2. The second function allows expansion flow from
valve. until the spring bias acts as a thermal relief. port 2 to port 1.
1
ThermalThermal
Relief (port
Relief
2-port
(port1)2-port 1) Free Flow
Free
(port
Flow1-port
(port2)1-port 2)
Flow L/min
Flow(21,8
L/mincSt
(21,8
oil @cSt
49°C)
oil @ 49°C) Flow (21,8
Flow - L/min - L/min (21,8
cSt oil @cSt oil @ 49°C)
49°C)
0 1 0 21 32 4 3 54 6 5 7 6 7 0 8 0 168 2416 3224 4032 4840 5648 56
5000 5000 350 350 100 100 7 7
Pressure Drop - psi
300 300
Pressure Override - psi
4000 4000 6 6
Pressure Drop - bar
80 80
250 250 5 5
3000 3000 60 60
200 200 4 4
2000 2000 150 150 40 40 3 3
100 100 2 2
1000 1000 20 20
50 50 1 1
0 0 0 0 0 0 0 0
0 0 0.5 0.51.0 1.01.5 1.5 0 2 0 4 2 6 4 8 6 10 8 121014 12 14
Flow - USgpm
Flow - USgpm
(105 SUS
(105
oil SUS
@ 120°F)
oil @ 120°F) Flow - USgpm
Flow - USgpm (105
(105 SUS oil SUS oil @ 120°F)
@ 120°F)
1 2 3 4 5 6 7 8 9
Dimensions
mm (inch)
Description Operation
The ADV1-16 is a poppet In its unpiloted position,
type, normally open, exter- this valve remains open
nally piloted, screw-in car- between port 1 and port 2
tridge type accumulator dis- until sufficient pilot pres-
charge valve. sure is applied to port 3.
Flow is then blocked from
port 1 to port 2.
1500 100
1000
50
500
0 0
0 2 4 6 8
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
12,0
Dimensions
(0.47)
mm (inch)
1
Ø 25,37 (0.999)
Ø 28,55 (1.124)
Description Operation
The PRV2-16 is a pilot This valve is normally open, the spool shifts to restrict setting of the valve, the
operated, spool type allowing flow from port 2 to the inlet flow at port 2. This spool will shift further and
screw-in cartridge pressure port 1. Port 3 must be vent- regulates the pressure at relieve excess pressure
reducing/relieving valve. ed. Once the pressure set- port 1. If pressure at port 1 through port 3.
ting is reached at port 1, exceeds the predetermined
4000 300
250
2
3000 200
150
1 2000
100
1000
50
0 0
40 30 20 10 0 10 20 30 40
Port 1 to 3 Port 2 to 1
Flow - USgpm (105 SUS oil @ 120ºF)
1 2 3 4 5 6 7 8 9
1.312”-12 Thd.
71,5 3
(2.81) Aluminum
housings can
• be used for
2
pressures up
to 210 bar (3000 psi).
Steel housings must be
1 used for operating pres-
Ø 26,95 (1.061)
sures above 210 bar
Ø 28,55 (1.124) (3000 psi).
This section gives basic Pilot operated check shock is obtained through pressure spring option
specifications for the full valves the use of several standard for effective anti-
line of Vickers screw-in These valves are used for: cracking pressure ranges cavitation protection.
cartridge check valves. Its • Position load locking from 2,0 bar (30 psi) to 7 • Unique design provides
purpose is to provide a • As an alternative to bar (100 psi). When compact package and
quick, convenient reference counterbalance valves anti-cavitation protection is low pressure drops that
tool when choosing Vickers where neither the required, the 0,30 bar (5 match or exceed current
cartridge valves or design- overrunning loads or psi) spring should be used. market expectations and
ing a system using these release speed are For those applications provide for excellent
components. factors in the where pilot pressure may repeatability and stability.
The Vickers range of direct application. not always be available, the
valve can be ordered with • 3:1 pilot ratio satisfies
and pilot operated check simple load holding
valves provides the The high pressure POC*-10 an optional adjustable
override. application requirements,
hydraulic circuit designer and POC*-12 series of while providing smooth
with a wide selection of pilot-to-open check valves Features and benefits operation and longer
cartridge and in-line complement the CBV*-10 • Products in this catalog operating life.
products. and CBV*-12 have been fatigue tested
counterbalance cartridges • Optional adjustable
Two pressure ratings are for one million cycles at override releases the
shown for all products and are physically 132% or 10 million cycles
interchangeable with them. load for situations where
featured in this catalog. The at 115% of rated pilot pressure is not
typical application pressure pressure. always available.
rating is the maximum The POC’s provide a low
cost alternative to load • Simple load holding Single pilot check
recommended operating device. Low cost
pressure for the valve in a control when the dynamics Also offered are SPC2-8
given system. The fatigue of neither overrunning loads alternative to more G
complex solutions when and SPC2-10 single pilot
pressure rating is the nor load release speed are check valves with
factors to be considered in overrunning loads are not
pressure for the valve to be present and / or control pressures to 240 bar (3500
free for infinite life from the design of the hydraulic psi) and flows to 23 L/min
circuit for the load to be of load release speed is
metal fatigue. not required. (6 USgpm). These valves
controlled. operate similar to the POC1
All poppet type check valve • Provides high operational
cartridges have hardened product but offer an
The pilot-to-open valves efficiency and low spring opposite flow path which
and ground poppets and positively lock a load from settings.
sharp-edged ground steel offers the designer a choice
port 1 to port 2 until pilot • Valves are offered with a of pilot operated check
seats. This provides an pressure applied to port 3
excellent product that is wide variety of standard valve when laying out a
is sufficient to unseat the housings with SAE and custom manifold for ease
dirt-tolerant, has reliable valve. This then permits
seating, and is suitable for BSPP port options in the of design.
flow from port 1 to port 2. following configurations:
fast cycling with long life. The load can also be Supporting products
– In-line single
Direct operated check released through means of – In-line dual Vickers screw in
valves an optional screw type – SAE, 4-bolt, code 61 cartridge valves are avail-
override. – Close coupled, nipple able in a wide range of
Cartridges fit into industry mounted mounting configurations
standard cavities and may The POC*-10 covers flow – Gasket mounted single and porting options to
be supplied for installation in up to 60 L/min (15 USgpm). – Gasket mounted dual provide flexibility in
manifolds, or be provided in The POC*-12 covers flow developing circuits.
up to 114 L/min (30 These valves can also be Housings are available in
standard housings having used in a C–10–3S or
USgpm). With infinite life either aluminum 210 bar
SAE or BSPP ports suitable qualification to a fatigue C–10–3S cavity. (3000 psi) or steel 350 bar
for in-line mounting. pressure rating of 310 bar • Four standard cracking (5000 psi) configurations.
(4500 psi), these POC pressures permit energy All are available with a
A wide selection of cracking valves are suitable for use savings, while tailoring choice of BSPP
pressures is available from in a broad range of load the hydraulic system (ISO–0228/1) or SAE style
0,21 to 20,7 bar (3 to 300 control applications with requirements to minimize ports.
psi). Thus the opportunity typical system operating shock.
exists to use the valves not pressures up to 350 bar
• Unique dual spring design
only as conventional check (5000 psi). Tailoring of the
provides high operational
but also as low pressure circuit to gain energy
efficiency and a low
relief valves. savings while minimizing
Description Operation
The CV3-4-B is a ball type, This valve remains closed poppet lifts off the seat and
screw-in cartridge check until the bias is reached at allows flow from port 1 to
valve. port 1 at which time the port 2.
2
Pressure Drop Curves Pressure vs. Flow - L/min (21,8 cSt oil @ 49° C)
Cartridge only 0 3.8 7.6
400 28
300 20
200 14
100 7
0
0 .5 1 1.5 2 2.5 3
Flow - USgpm (105 SUS oil @ 120° F)
1 2 3 4 5 6 7
G
Dimensions
mm (inch) 9/16" HEX
Torque cartridge in 12,73
aluminum or steel housing (.501)
to 8.1-13.6 Nm (6-10 ft. lbs)
7/16 - 20 UNF - 2A
21,82
(.859)
2
1
Ø 8,64 (.340)
Description Operation
The CV16-10-P is a poppet This valve remains closed time the poppet lifts off the
type, screw-in cartridge until the spring bias is seat and allows flow from
check valve. reached at port 2 at which port 2 to port 1.
90
6
70 A
50
B 3
30
C
D
2 4 6 8 10 12 14 16 18
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8
1
Ø 15,80 (0.622)
WARNING
The cavity should be machined to Aluminum housings can be used for
the 14,29 (0.562) maximum diameter pressures up to 210 bar (3000 psi)
and 36,00 (1.417) maximum depth Steel housings must be used for
(see cavity detail, page M-12). operating pressures above 210 bar
(3000 psi)
Description Operation
The CV11-12 is a poppet This valve remains closed time the poppet lifts off the
type, screw-in cartridge until the spring bias is seat and allows flow from
check valve. reached at port 1 at which port 1 to port 2.
1
Pressure Drop Curves
A – CV11-12-P-O-80
Cartridge only
B – CV11-12-P-O-20
Flow - L/min (21,8 cSt oil @ 49°C) C – CV11-12-P-O-2.5
20 40 60 80 100
300 18
Pressure Drop - bar
Pressure Drop - psi
250 16
14
200 12
150 10
A 8
100 6
B
50 4
C
2
0
0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9
Dimensions
mm (inch) 1,6 (1.25) hex
18,9
Torque cartridge in housing (0.75)
A - 81-95 Nm
(60-70 ft. lbs) 1.062"–12 Thd.
S - 102-115 Nm
(75-85 ft. lbs)
44,7
(1.76)
Aluminum
housings can be 2
used for
pressures up to
210 bar (3000 psi)
Steel housings must be 1
used for operating Ø 23,75 (0.935)
pressures above 210 bar
(3000 psi).
7,95
(.313)
1" HEX
0.875"-14 Thd.
2 31,67
(1.247)
Description Operation
The CV6-10-P is a poppet This valve acts a restrictor
type, screw-in cartridge in the 2 to 1 direction and
1
check valve with bypass as a check valve it allows
Ø 15,8 (.622)
orifice. free flow from 1 to 2.
1 2
Pressure Drop Curves Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60 80
500
30
400
Pressure Drop - psi
CV6 10 * P * ** *** ** 00
1 2 3 4 5 6 7 8 9
Dimensions
mm (inch) 8,0 (0.31)
25,4 (1.0) hex
Torque cartridge in housing
A - 47-54 Nm
(35-40 ft. lbs) 0.875"–14 Thd.
S - 68-70 Nm
(50-55 ft. lbs)
31,7
(1.25)
2
1
Ø 15,80 (0.622)
1.5" HEX
1.312"-12 Thd.
44,58
(1.75)
Description 2 Operation
2 2
The CV6-16-P is a poppet This valve acts a restrictor
type, screw-in cartridge in the 2 to 1 direction and
check valve
1 with bypass as a check valve1 it allows 1
orifice. free flow from 1 to 2. Ø 28,53 (1.123)
1 2 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 151 L/min (40 USgpm)
Sectional View Free flow cracking pressure @1 L/min (0.25 USgpm) 005 – 0,34 bar (3 psi)
020 –1,34 bar (2012,7
psi)
030 – 2,07 bar (30(psi)
.500)
050 – 3,45 bar (50 psi)
Orifice size range 1.5" HEX 0.015 - 0.125 inch (0.381 - 3.175 mm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids 1.312"-12 Thd.
All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code44, 58
18/16/13
(1.75)
Standard housing materials Aluminum
2 Weight cartridge only 0,26 kg (0.58 lbs)
2 2
Seal kit 565810 Buna–N
889609 Viton®
Viton is a registered trademark of E.I. DuPont
1 1 1
Ø 28,53 (1.123)
6
A - CV6 16*P 0000 050 00 75
B - CV6 16*P 0000 020 00 A
4
C - CV6 16*P 0000 005 00 50
B
C
2
25
0 10 20 30 40
Flow - USgpm (105 SUS oil @ 120°F)
Port 1 to 2
1 2 3 4 5 6 7 8 9
Dimensions 12,7
mm (inch) (.500)
1.5" HEX
Torque cartridge in
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312"-12 Thd.
44,58
(1.75)
2 2
1 1
Ø 28,53 (1.123)
Description Operation
The RV3-10 is a direct This valve remains closed has been reached at port 2.
acting, differential area, from port 2 to port 1 until The poppet is unseated and
poppet type, screw-in the predetermined setting allows flow out of port 1.
cartridge relief valve.
2
3000 210
A
1 A - 36 spring
B - 18 spring 2000 140
C - 6 spring B
1000 70
C
0 0
0 5 10 15 20
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9 10
53,0
(2.08)
25,4 (1.0) hex
Aluminum
housings can
0.875"-14 Thd. • be used for
31,8 pressures up
(1.25) to 210 bar (3000 psi).
2 Steel housings must be
used for operating pres-
1 sures above 210 bar
Ø 15,82 (0.623) (3000 psi).
This section gives basic • Flow divider/combiners For example: FDC*1-10-*–66 This valve is used in place
specifications for the com- (FDC1 and FDC11) with will divide an incoming flow of a standard flow divider-
plete line of Vickers thread- flows rated to 568 L/min of 45 L/min (12 USgpm) combiner in systems where
ed cartridge flow control (150 USgpm). equally out each port with hydraulic motors are used
valves. Its purpose is to • Posi-traction valves an accuracy of 10% each as drive wheels on each
provide a quick, convenient (FDC13) with flows rated side. With 45 L/min (12 side of the machine. The
reference tool when choos- to 567 L/min (150 USgpm) in at “3” port, flow positive traction valve acts
ing Vickers cartridge valves USgpm) out port “4” can be 22 much like a standard flow
or designing a system L/min (6 USgpm) 4,5 L/min divider-combiner as the
using these components. • Operating pressures to (1.2 USgpm) while flow at vehicle travels in a straight
350 bar (5000 psi). port “2” is 22,7 L/min (6 line. Equal amounts of flow
Valve Features and Here are some of the bene- USgpm) 4,5 L/min (1.2 go to each “C” port. As the
Benefits fits of Vickers flow USgpm). vehicle turns a corner, a
Eaton offers a complete controls: The combining accuracy is standard flow divider will
range of Vickers flow con- the same with incoming maintain equal flow to each
• All operating parts are
trols cartridge valves, with a flow at port “4” and “2” drive motor. On a turn, it is
hardened steel, ground
variety of features, including: and flow out port “3” of 45 necessary for the outer
and honed for long life
and low leakage. L/min (12 USgpm). Inlet wheel to turn faster than F
• Products in this catalog the inner wheel. A standard
have been Fatigue tested flow at port “4” will be 22
• Designed for maximum flow divider-combiner will
to one million cycles L/min (6 USgpm) 4,5 L/min
flexibility and minimal provide equal flow to each
at 132% or 10 million (1.2 USgpm). Inlet flow at
space requirements. motor causing the drive
cycles at 115% of rated port “2” will be 22 L/min (6
• All exposed cartridge sur- USgpm) 4,5 L/min (1.2 motors to skid. The positive
pressure. traction valve solves this
faces are zinc dichromate USgpm).
• Non-adjustable, pressure plated to resist corrosion. problem by allowing the
compensated, flow regu- Flow division or combining one motor to turn faster
Steel housings are avail-
lator for flows to 227 will be maintained even if than the other.
able for cartridges rated
L/min (60 USgpm). unequal loads are placed on
to 350 bar (5000 psi) This operates in a similar
ports “4” and “2”.
• Adjustable, pressure application pressures. way as a mechanical differ-
compensated, flow regu- A special feature of the ential on an automobile. In
• All aluminum manifolds
lator for flows to 114 FDC*1–** is that it provides a turn, the inside drive
are gold anodized to
L/min (30 USgpm). rephase flow to either port motor is restricted and
resist corrosion.
2 or port 4 when one of the builds up pressure, while
• Fixed and adjustable pri- • Reliable, economical and two is blocked. This feature the outside drive motor is
ority bypass type flow compact. is useful in hydraulic circuits without restriction. Under
regulator for regulated that require cylinders to conditions of high differen-
• Low leakage.
flows to 114 L/min (30 move at the same time. If tial pressure, the positive
USgpm). • Variety of adjustment one cylinder bottoms out
options. traction valve passes extra
• Adjustable flow control first, the opposite cylinder is flow to the least restricted
without free reverse flow • Adjustments designed provided with “rephase” motor to prevent skidding.
check with flows rated to not to go spring solid at flow to allow the cylinder to Under straight running con-
114 L/min (30 gpm). “full in” position or to bottom and start the cylin- ditions the differential pres-
allow the adjustment to ders together for movement sure is low and equal
• Adjustable flow control in the opposite direction.
be removed when amounts of flow are provid-
with free reverse flow
backed out. ed to each drive motor.
check with flows rated to
Notable are the two styles FDC3/FDC13
45 L/min (12 gpm).
of flow divider/combiner: The FDC*3 is a cartridge WARNING
• Needle valves with flows
type positive traction valve For pressure over
rated to 265 L/min (70 •
FDC1/FDC11 that divides and combines 210 bar (3000 psi)
USgpm).
The FDC*1 is a cartridge flow, regardless of system use steel housing.
• Velocity fuses with flows load or pressure, propor-
type hydraulic flow divider-
rated to 227 L/min (60 tionally per specified flow
combiner valve. It divides
USgpm). division.
and combines flow, regard-
less of system load or pres-
sure, proportionally per
specified flow division.
Description Operation
The NV1–10 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in either wise.
direction, from full flow to
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Functional Symbol Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
2 Cavity C–10–2
1 F
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,11 kg. (0.24 lbs.)
Seal Kits 565806 Buna–N
889627 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
70 5
Pressure drop - bar
Pressure drop - psi
60 4
50
3
2 40
30 2
1 20
1
10
0 0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
47–54 Nm (35–40 ft.lbs)
Ø42,0
(1.65)
43,0
(1.69)
1
Ø15,80 (0.622)
Description Operation
The FCV11–12 is a direct This valve is non-pressure from full flow to tight shut
acting, adjustable needle compensated. Flow is con- off, by turning the adjust-
valve. trolled in either direction, ment feature clockwise.
Sectional View
Pressure Drop Curve Flow - L/min (21,8 cSt oil @ 49°C)
Cartridge only 20 40 60 80 100
A – Cartridge with C-12-2 90 6,21
valve body, full open 80 5,52
B – Cartridge with C-12-2U 70 4,83
1 10 0,5
0
0 5 10 15 20 25 30
1 2 3 4 5 6 7 8 9
1.063"–12
Thd.
44,6
(1.80)
2
Aluminum hous-
ings can be used
• for pressures up to
1 210 bar (3000 psi)
Ø23,75 (0.935) Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The FCV6-16 is a non-pres- This valve allows flow counterclockwise. In the full
sure compensated, between ports 1 and 2 clockwise position this valve
adjustable, flow restrictor. through an increasing provides tight shut-off.
variable orifice when the
Functional Symbol adjustment is turned
80
70 5
1 60 4
50
3
40
30 2
20
1
10
0
0 10 20 30 40 50 60
Flow - USgpm (105 SUS @ 120°F)
1 2 3 4 5 6 7
Dimensions
mm (inch)
Torque cartridge in
aluminum housing to
108–122 Nm (80–90 ft.lbs)
"S" Adjustment
4,8 (0.18) hex "C" Adjustment
"K" Adjustment 19,1 (0.75) hex
Ø38,1 (1.50)
59,0
51,0 51,0 (2.32)
(2.00) (2.00)
38,1 (1.5) hex
1
Ø28,55 (1.124)
Description Operation
The NV1–16 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical Typical application pressure (all ports) 210 bar (3000 psi)
direction Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
of flow
Rated flow 151 L/min (40 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F) F
1 Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Sectional View Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,34 kg. (0.76 lbs.)
Seal kits 565810 Buna–N
889609 Viton®
Viton is a registered trademark of E.I. DuPont
2
70 5
1 60
4
Pressure drop - bar
Pressure drop - psi
50
Application Note 3
40
The valve is not intended
for use at low flows, may 30 2
chatter below 10 L/min
(2.5 gpm) 20
1
10
0
0 10 20 30 40
Flow - USgpm (105 SUS oil @ 20°F)
1 2 3 4 5 6
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
108–122 Nm (80–90 ft.lbs)
Ø61,0
(2.40)
61,0
(2.40)
44,4
(1.75) 2
1
Ø28,55 (1.124)
Description Operation
The NV1–20 is a direct-act- This needle valve is non- tight shut-off, by turning the
ing, adjustable, screw-in pressure compensated. adjustment feature clock-
cartridge type needle valve. Flow is controlled in the wise. The flow from port 1
direction from port 2 to to port 2 will be restricted.
Functional Symbol port 1, from full flow to
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Typical
direction Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
of flow Rated flow 265 L/min (70 USgpm)
Internal leakage 5 drops/min. maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–20–2
F
1
Fluids All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum
Weight cartridge only 0,59 kg. (1.3 lbs.)
Seal kits 889615 Buna-N
889619 Viton ®
Viton is a registered trademark of E.I. DuPont
40 3
Application Note 30 2
The valve is not intended
20
for use at low flows, may
1
chatter below 10 L/min 10
(2.5 gpm)
0 0
0 10 20 30 40 50 60 70
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
128–155 Nm (95–115 ft.lbs)
Ø61,0
(2.40)
62,0
(2.44)
47,6 (1.87) hex
1
Ø36,47 (1.436)
Description Operation
The MRV2-10 is a 2-way, This valve will increase or rotary adjustment.
2 position, manual decrease flow by changing Recommended flow path
semi-rotary screw-in flow the variable orifice with the is 2 to 1.
restrictor valve. RATINGS AND SPECIFICATIONS
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 05 – 0-18,9 L/min (0–5 USgpm)
10 – 0-37,8 L/min (0–10 USgpm)
15 – 0-56,7 L/min (0–15 USgpm)
Internal leakage 164 cm3 /min. (10 in3/min)
maximum 210 bar (3000 psi)
Functional Symbol Temperature range -40° to 120°C (-40° to 248°F)
Manual operators B – Ball lever (friction lock)*
E – Ball lever (10 position detent)*
2 1 D – Lever (10 position detent)* F
L – Lever (friction lock)*
*Light duty housings only K – Knob (non-locking)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 561810 Buna-N
Sectional View 889609 Viton®
Viton is a registered trademark of E.I. DuPont
A - 05
1 6
B - 10
5
C - 15
4
3
2
1
0
0 2 4 6 8 10 12 14
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7
41,0 38,1
(1.60) 58,0
(1.50) X (2.28)
X X X
42,0 42,0
(1.65) (1.65)
0.875"-14 Thd.?
31,7
(1.25) 2
Ø3,45-3,50 0
(#29 or 0.136+0.002)
1 x 4,76 (0.187)
Ø15,80 (0.622) in mating housing
Description Operation
The MRV2-16 is a 2-way, 2 This valve will increase or Recommended flow path
position, manual semi- decrease flow by changing is 2 to 1.
rotary screw-in flow restric- the variable orifice with the
tor valve. rotary adjustment.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Rated flow 10 – 0-37,8 L/min (0–10 USgpm) 30 – 0-113,5 L/min (0–30 USgpm)
15 – 0-56,7 L/min (0–15 USgpm) 35 – 0-132,4 L/min (0–35 USgpm)
20 – 0-75,7 L/min (0–20 USgpm) 40 – 0-151,4 L/min (0–40 USgpm)
Functional Symbol 25 – 0-94,6 L/min (0–25 USgpm) 45 – 0-170,3 L/min (0–45 USgpm)
Internal leakage 82 cm3 /min. (5 in3 /min
maximum 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
F
2 1
Manual operators D – Lever (10 position detent)
L – Lever (friction lock)
K – Knob (non-locking)
Light duty housings only
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Sectional View Weight cartridge only 0,79 kg (1.74 lb.)
Seal kits 565810 Buna-N
889609 Viton®®
Viton is a registered trademark of E.I. DuPont
Pressure Drop Curve Rated flow
Cartridge only (See model code position 6)
A - 10 E - 30
@ 5,5 bar (80 psi) B - 15 F - 35
pressure drop C - 20 G - 40
Flow - L/min (21,8 cSt oil @ 49°C) D - 25 H - 45
1
6
5
4
3
2
1
0 4 8 12 16 20 24 28 32 36 40 44
Flow - USgpm (105 SUS oil @ 20°F)
1 2 3 4 5 6 7
76,0
X X (3.00)
6,0
(2.40)
A
(105 SUS oil @ 120°F)
Flow - L/min
8
Flow - USgpm
2.0
6
1.5
4
A – 9,5 L/min (2.5 USgpm) 1.0
B
B – 1,9 L/min (0.5 USgpm) 0.5 2
C – 0,38 L/min (0.1 USgpm) C
0
0 1000 2000 3000 4000 5000
Pressure - psi
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
1
Ø12,62 (0.497) Aluminum hous-
ings can be used
• for pressures up to
210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The FR1-16-F is a This valve maintains a con- port 2. Reverse flow from
fixed orifice, pressure com- stant flow from port 1 to port 2 to port 1 is at the
pensated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.
2
Pressure - bar
0 70 140 210
35 140
1 A
(21,8 cSt oil @ 49°C)
(105 SUS oil @ 120°F)
30 120
Flow -L/min
Flow - USgpm
25 100
20 80
15 B 60
10 40
C 20
5
0 0
0 1000 2000 3000
Pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing to
108-122 Nm (80-90 ft.lbs)
1.312" -12 Thd.
44,4
(1.75) 2
1
Ø28,55 (1.124)
Description Operation
The FR1-20-F is a fixed This valve maintains a con- port 2. Reverse flow from
orifice, pressure compen- stant flow from port 1 to port 2 to port 1 is at the
sated, screw-in flow port 2 based on 5.5 bar (80 value of the fixed orifice
regulator cartridge valve. psid) regardless of pressure and is non-pressure
changes downstream on compensated.
Pressure - bar
2 0 70 140 210
70 280
(21,8 cSt oil @ 49°C)
(105 SUS oil @ 120°F)
60 A 240
Flow - L/min
Flow - USgpm
1 50 200
40 160
B
30 120
20 C 80
10 40
0 0
0 1000 2000 3000
Pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
38,1 47,2 (1.87) hex
Torque cartridge in
aluminum housing to (1.50)
128-155 Nm (95-115 ft.lbs)
1.625" -12 Thd.
57,1
2
(2.25)
Ø36,47 (1.436)
Description Operation
The FR2-16 is a limited This valve maintains a con- stream on port 2. Reverse
range adjustable*, pressure stant flow from port 1 to flow from port 2 to port 1 is
compensated, screw-in port 2 based on the setting at the value of the fixed ori-
flow regulator cartridge adjustment, regardless of fice and is non-pressure
valve. pressure changes down compensated.
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow 114 L/min (30 USgpm)
2 Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,71 kg (1.57 lbs.)
Seal kits 565810 Buna-N
889609 Viton®
Sectional View Viton is a registered trademark of E.I. DuPont
A
(21,8 cSt oil @ 49°C)
120
Flow - USgpm
30
Flow - L/min
90
20
B 60
10
30
C
2
0 0
0 500 1000 1500 2000 2500 3000
1 Pressure drop - psi
1 2 3 4 5 6 7
107,2 104,0
(4.22) (4.09)
1
Ø28,55 (1.124)
Description Operation
The FAR1–10 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor, screw-in cartridge valve sure changes upstream of regulated flow base within and counter- clockwise to
with free reverse flow. port 1, or downstream of the adjusting range from 1 increase the flow. This valve
port 2. 13.8 bar (200 psi) to 38 lpm (0.25 to 10 allows free reverse flow
Functional Symbol from port 2 to port 1.
2 RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 5–350 bar (75–5000 psi) steel housing
Min. pressure differential across valve 14 bar (200 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 1–38 L/min (.25–10 USgpm)
Flow regulation accuracy 4–38 L/min (1–10 USgpm) ±10%
1 1–4 L/min (0.25–1 USgpm) ±20%
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Sectional View
Reverse check crack pressure 1.7 bar (25 psi)
Leakage at shutoff position 0.4 L/min (24.4 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,02 kg (0.44 lbs.)
“K” 0,23 kg (0.51 lbs.)
“H” 0,26 kg (0.59 lbs.)
Seal kits 565803 Buna-N
566086 Viton®
Viton is a registered trademark of E.I. DuPont
2
Typical Flow Regulation
Cartridge only
1
PRESSURE DROP FOR REVERSE FLOW TYPICAL FLOW REGULATION
Flow - L/min (21,8 cSt oil @ 49ºC) Pressure differential across valve in bar
8 16 24 32 40 70 140 210 280 350
200 12
40
(105 SUS oil @ 120°F)
12
(21,8 cSt oil @ 49°C)
10
Pressure drop - bar
Pressure drop - psi
150
Flow - USgpm
32
Flow -L/min
8
8
100 6 24
4 16
4
50
2 8
1 2 3 4 5 6 7 8
Description Operation
The FAR1–12 is a two-way, This valve maintains a con- the valve to obtain pressure clockwise to decrease the
fully adjustable, pressure stant flow from port 1 to compensated control. The flow and counter- clockwise
compensated, flow regula- port 2 regardless of pres- regulated flow base within to increase the flow. This
tor, screw-in cartridge valve sure changes upstream of the adjusting range from valve allows free reverse
with free reverse flow. port 1, or downstream of 1,5 to 94,5 lpm (0.4 to 25 flow from port 2 to port 1.
port 2. 15,9 bar (230 psi) USgpm) is set by turning
Functional Symbol must be maintained across the adjusting screws
2
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 315 bar (4500 psi)
Min. pressure differential across valve 15,9 bar (230 psi)
Max. pressure differential across valve 329 bar (4770 psi)
1 Rated flow 1,5–94,5 L/min (.4–25 USgpm)
Sectional View Flow regulation accuracy 1,5–3,8 L/min (.4–1.0 USgpm) ±20% @5000 psi
above 3,8–68,1 L/min (above 1–18 USgpm) ±10% @3000 psi
above 68,1–94,6 L/min (above 18–25 USgpm) ±15% @3000 psi
3,8–56,8 L/min (1–15 USgpm) ±10% @5000 psi
above 56,8–89,1 L/min (above 15–23 USgpm) ±15% @5000 psi
Factory set maximum flow rate accuracy under standard test conditions and within the above ranges
Reverse check crack pressure 1,7 bar (25 psi)
Leakage at shutoff position 0,5 L/min (30 in3/min)
Temperature range –40° to 120°C (–40° to 248°F)
Cavity C–12–2 & C–12–2U
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only “S” 0,43 kg (0.95 lbs.)
Seal kits 02–181304 Buna-N
2 02–181305 Viton®
Viton is a registered trademark of E.I. DuPont
12 75
20
(21,8 cSt oil @ 49°C)
150
Flow - L/min
Flow - USgpm
16 60
8
100 12 45
8 30
50 4
4 15
1 2 3 4 5 6 7 8
Description Operation
The FAR1–16 is a two-way, This valve maintains a con- must be maintained across USgpm) is set by turning
fully adjustable, pressure stant flow from port 1 to the valve to obtain pressure the adjusting screws clock-
compensated, flow regula- port 2 regardless of pres- compensated control. The wise to decrease the flow
tor screw-in cartridge valve. sure changes upstream of regulated flow base within and counter- clockwise to
port 1, or downstream of the adjusting range from increase the flow. This valve
Functional Symbol port 2. 17 bar (250 psi) 3,8 to 113,6 L/min (1.0 to 30 allows free reverse flow
2 from port 2 to port 1.
12 120
Pressure drop - psi
30
Pressure drop - bar
Flow - USgpm
Flow - L/min
150 100
24 80
8
100 18 60
4 12 40
50
6 20
1 2 3 4 5 6 7 8
1 Function 6 Port size & valve bodies 7 Factory set flow rate
Description Operation
The PFR5–8 is a fixed ori- This valve maintains a con- changes downstream on the spool will shift to try
fice, priority type, pressure stant, factory-set, priority port 3. Flow in excess of and satisfy the priority flow
compensated, flow regula- flow from port 1 to port 3 the priority setting is direct- requirement, thereby clos-
tor, screw-in cartridge based on 5.5 bar (80 psid) ed to port 2. If the priority ing off flow to port 2.
valve. regardless of pressure flow at port 3 is blocked,
3 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi) in steel housing
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated flow maximum inlet flow 15,1 L/min (4 USgpm)
maximum regulated flow 10 L/min (2.5 USgpm)
2
Internal leakage 82 cm3 /min. @ 350 bar (3000 psi) 5 in3 /min @ 5000 psi) F
Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
1 0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi)
5,7–10 L/min (1.5–2.5 USgpm) ±10% @ 350 bar (5000 psi)
Sectional View Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–8–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,07 kg (0.15 lb.)
3 Seal kits 02–173427 Buna-N
02–173434 Viton®
Viton is a registered trademark of E.I. DuPont
2.5 10
(105 SUS oil @ 120°F)
Flow - L/min
2.0 8
1.5 6
1.0 4
0.5 2
0
0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Priority pressure
higher than priority higher than bypass
Pressure - psi
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
0.750"–16 Thd.
40,6 3
(1.60)
Aluminum hous-
1 ings can be used
Ø14,2 (0.559) • for pressures up to
210 bar (3000 psi)
Ø15,8 (0.622) Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The PFR5-10-F is a fixed This valve maintains a con- changes downstream on the spool will shift to satis-
orifice, priority type, stant, factory-set, priority port 3. Flow in excess of fy the priority flow require-
pressure compensated, flow from port 1 to port 3 the priority setting is direct- ment, thereby closing off
flow regulator screw-in based on 5.5 bar (80 psid) ed to port 2. If the priority flow to port 2.
cartridge valve. regardless of pressure flow at port 3 is blocked,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Functional Symbol Rated flow Maximum inlet flow 60 L/min (15 USgpm)
Maximum regulated flow 23 L/min (6 USgpm)
3 Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi)
0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi)
1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi) F
5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges.
Pressure - bar
350 280 210 140 70 0 70 140 210 280 350
6.0 24
3
5.0 20
(105 SUS oil @ 120°F)
Flow - L/min
4.0 16
2
3.0 12
2.0 8
1
1.0 4
0 0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Pressure - psi Priority pressure
higher than priority higher than bypass
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
0.875"?-14 Thd.
46,0
(1.81) 3
1
Aluminum hous-
Ø15,82 (0.623) ings can be used
• for pressures up to
210 bar (3000 psi)
Ø17,42 (0.686) Steel housings must be used
for operating pressures above
210 bar (3000 psi)
Description Operation
The PFR2-16 is a limited This valve maintains a con- of pressure changes down- blocked, the spool will shift
range adjustable*, priority stant, factory-set, priority stream on port 3. Flow in to satisfy the priority flow
type, pressure compensat- flow from port 1 to port 3 excess of the priority set- requirement, thereby clos-
ed, flow regulator screw-in based on the setting adjust- ting is directed to port 2. If ing off flow to port 2.
cartridge valve. ment, regardless the priority flow at port 3 is
*The flow adjustment is from the factory
set maximum flow rate down to 50% of RATINGS AND SPECIFICATIONS
that factory set flow rate. Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated flow Maximum inlet flow 151 L/min (40 USgpm)
Maximum regulated flow 114 L/min (30 USgpm)
3
Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15%
11,4–114 L/min (3–30 USgpm) ±10% F
Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges
Temperature range -40° to 120°C (-40° to 248°F
2 Cavity C–16–3
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
1 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,43 kg (0.95 lb.)
Seal kits 565811 Buna-N
Sectional View 889610 Viton®
Viton is a registered trademark of E.I. DuPont
100
25
A
(105 SUS oil @ 120°F)
80
(21,8 cSt oil @ 49°C)
20
B
60
15
A
3
40
10
B
2
20
5
1 0
0
0 500 1000 1500 2000 2500 3000
Back pressure - psi
1 2 3 4 5 6 7
Dimensions
mm (inch)
"C" Adjustment "S" Adjustment
9,6 (0.37) hex "K" Adjustment,
Torque cartridge in 19,0 (0.75) hex
aluminum housing to Ø51 (2.0)
108–122 Nm (80–90 ft.lbs)
107,2 104,0
(4.22) (4.09)
73,0 3
(2.87)
2
1
Ø26,95 (1.061)
Ø28,55 (1.124)
Description Operation
The PFR*-12 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to maximum
tems in steering and brak- ports 2 and 4 must be pro- pressure.
ing circuits. The static type vided by external relief
F
3 P
RATINGS AND SPECIFICATIONS
Static Signal (PFRS)
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF
Typical application pressure (all ports) 280 bar (4000 psi)
4 2
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
1 Rated inlet flow 76 L/min (20 USgpm)
LS 5
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–12–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Profile View Filtration Cleanliness code 18/16/13
Housing materials Aluminum or Steel
Weight cartridge only 0,36 kg (0.79 lb.)
Seal kit 202914-921
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.031” (not included in valve)
218 15
Pressure drop psi
3 P
2 EF 145 10
Notes
Minimum inlet flow should 73 5
1 not be less than 1/4 of
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF
1 2 3 4 5 6 7
PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 055 psi (3.8 bar)
PFRD – Priority flow 078 psi (5.4 bar)
000 No Body – – –
regulator 100 psi (6.9 bar)
Dynamic signal type 10T SAE 10 SAE 4 4998820-001 4998821-001 PFRD options
12T SAE 12 SAE 4 4998820-002 4998821-002 075 psi (5.2 bar)
2 Size 110 psi (7.6 bar)
04G 1/2” BSPP 1/4” BSPP 4998820-003 4998821-003
12 – 12 Size 145 psi (10.0 bar)
06G 3/4” BSPP 1/4” BSPP 4998820-004 4998821-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)
Dimensions
mm (inch)
Note
1 1/16"-1 2 UN-2A
Standard housings include
port 1, however for most
applications this port must
be blocked. 5 LS
4 CF
86.4
(3.40)
3 P Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
1 210 bar (3000 psi)
Description Operation
The PFR*-16 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sens- flow control mode. Pump applications where is determined by assuring
ing priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
Dynamic Signal (PFRD)
port 2. The valve maintains response or circuit stability control pressure must be
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 The pressure at port 4 can
changes at 2 or 4. This Meters (6 Feet) in length. vary by 10% when the load
LS 5 1 valve is typically used with Overpressure protection for at the excess flow port 2
open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be pro- sure.
ing circuits. The static type vided by external relief
F
3 P
RATINGS AND SPECIFICATIONS
Static Signal (PFRS) Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
CF EF Typical application pressure (all ports) 280 bar (4000 psi)
4 2 Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 150 L/min (40 USgpm)
LS 5 1
Temperature range -40° to 100° C (-40° to 210° F)
Cavity C–16–5S
Fluids All general purpose hydraulic fluids such as:
3 P MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Profile View Housing materials (standard) Steel
Weight cartridge only 0,47 kg (1.05 lbs.)
Seal kit 202915-922
Internal leakage 164cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.036” (not included in valve)
5 LS
Pressure Drop Curves Flow - L/min
38 75 114 151
Cartridge only 250
4 CF
14
Pressure drop psi
200
Pressure drop bar
3 P
150 10
2 EF
100 7
1 Notes
Minimum inlet flow should
50 3
not be less than 1/4 of
maximum inlet flow.
0
Note Minimum pressure drop 0 5 10 15 20 25 30 35 40 45
Port 1 unused, port should is determined by control Flow - USgpm
be plugged. pressure. P to EF
1 2 3 4 5 6 7
PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 065 psi (4.5 bar)
PFRD – Priority flow 130 psi (8.9 bar)
000 No Body – – –
regulator 160 psi (11.0 bar)
Dynamic signal type 12T SAE 12 SAE 4 4994880-001 4994881-001 PFRD options
16T SAE 16 SAE 4 4994880-002 4994881-002 080 psi (5.5 bar)
2 Size 110 psi (7.6 bar)
06G 3/4” BSPP 1/4” BSPP 4994880-003 4994881-003
16 – 16 Size 130 psi (9.0 bar)
08G 1” BSPP 1/4” BSPP 4994880-004 4994881-004
3 *These model digits will not be stamped on the valve. 7 Special features
Seals
U– Urethane (standard) See section J for housing details. 00 – None
(Only required if valve has
4 Body special features, omitted
O – Cartridge only if “00”.)
A – Aluminum
S – Steel (standard)
Dimensions
mm (inch)
4 CF
96.3 (3.79)
3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1
Description Operation
The PFR*-20 is a spool This valve is used in the is used for less difficult valves. The control pressure
type, screw-in, load-sensing flow control mode. Pump applications where is determined by assuring
priority flow regulator flow from the valve inlet response or circuit stability adequate inlet pressure to
cartridge valve. port 3 is delivered first to is not a problem. The the steering unit and must
port 4 at a fixed rate; dynamic type is used for be matched to the steering
Functional Symbols excess flow is bypassed to difficult applications where unit’s required flow. The
port 2. The valve maintains response or circuit stability control pressure must be
Dynamic Signal (PFRD)
the controlled flow to 4 are critical. The load sense supplied to the valve as a
CF EF regardless of inlet pressure line connected to port 5 minimum inlet pressure.
4 2 change or load pressure should not exceed 2 Meters The pressure at port 4 can
changes at 2 or 4. This (6 Feet) in length. vary by 10% when the load
valve is typically used with Overpressure protection for at the excess flow port 2
LS 5 1
open loop load sense sys- the circuits connected to varies from 0 to max pres-
tems in steering and brak- ports 2 and 4 must be sure.
ing circuits. The static type provided by external relief
F
3 P RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Static Signal (PFRS)
Typical application pressure (all ports) 240 bar (3500 psi)
CF EF Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
4 2 Rated inlet flow 230 L/min (60 USgpm)
Temperature range -40° to 100° C (-40° to 210° F)
LS 5 1
Cavity C–20–5S
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
3 P Filtration Cleanliness code 18/16/13
Housing materials (standard) Steel
Profile View Weight cartridge only 0,86 kg (1.9 lbs.)
Seal kit 02-187543
Internal leakage 164 cc/min (10 in3/min) @ 3000 PSID
Recommended L/S orifice 0.047” (not included in valve)
3 P
150
2 EF 100 7
Note
Minimum inlet flow should
not be less than 1/4 of 50
maximum inlet flow.
1
0
Note Minimum pressure drop 10 20 30 40 50 60
Port 1 unused, port should is determined by control Inlet flow (GPM)
be plugged. pressure.
1 2 3 4 5 6 7
PFRS – Priority flow regulator CODE PORT SIZE HOUSING NUMBER PFRS options
Static signal type Port 2, 3, 4 Port 5 Aluminum Steel 080 psi (5.5 bar)
PFRD – Priority flow regulator 100 psi (6.9 bar)
000 No Body – – –
Dynamic signal type PFRD options
12T SAE 12 SAE 4 4998822-001 4998823-001 085 psi (5.9 bar)
2 Size 16T 110 psi (7.6 bar)
SAE 16 SAE 4 4998822-002 4998823-002
20 – 20 Size 06G 3/4” BSPP 1/4” BSPP 4998822-003 4998823-003 7 Special features
3 08G 1” BSPP 1/4” BSPP 4998822-004 4998823-004
Seals 00 – None
* These model digits will not be stamped on the valve. (Only required if valve has
U– Urethane (standard)
See section J for housing details. special features, omitted
4 Body if “00”.)
O – Cartridge only
A – Aluminum
S – Steel (standard)
Dimensions
mm (inch)
3 P
Aluminum hous-
ings can be used
• for pressures up to
2 EF 210 bar (3000 psi)
Steel housings must be used
for operating pressures above
210 bar (3000 psi)
1
Description Operation
The PCS4-10 is a screw-in, This valve, when used with port 3. This is based on priority port is deadheaded,
pressure compensator either a fixed or variable whatever pressure differen- the valve will try to direct
cartridge for the use orifice on port 4, maintains tial is chosen. All flow in flow out of the priority port
as a bypass or priority a constant flow out port 3, excess of the priority and shut off the bypass
flow control. regardless of pressure requirement is bypassed flow, blocking of all flow.
changes downstream of from port 1 to port 2. If the
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Functional Symbols Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 38 L/min (10 USgpm)
Cavity C–10–4
Variable
or fixed Standard housing materials Customized housings are
restrictor necessary for close-coupling
upstream the compensator and orifice
4 3 Temperature range -40° to 120°C (-40° to 248°F)
1 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,14 kg (0.32 lbs)
Seal kits 889651 Buna-N
889653 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
0.200 5
Approx. orifice diameter - mm
0.175
3 A 4
0.150
B
0.125
C 3
0.100
2 0.075 2
0.050
1
0.025
1 0 0
0 1 2 3 4 5 6 7 8 9 10
Controlled flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
00 – None
(Only required if valve has
special features, omit if 00)
Dimensions
mm (inch)
19,0 I
Torque into aluminum (0.75) 25,4 (1.00) hex
housing to 47-54 Nm
(35-40 ft. lbs)
4
61,9
(2.43)
3
1
15,80 (0.622)
17,40 (0.685)
18,97 (0.747)
Description Operation
The PCS4-12 is a screw-in, This valve, when used with port 3. This is based on priority port is deadheaded,
pressure compensator either a fixed or variable whatever pressure differen- the valve will try to direct
cartridge for the use orifice on port 4, maintains tial is chosen. All flow in flow out of the priority port
as a bypass or priority a constant flow out port 3, excess of the priority and shut off the bypass
flow control. regardless of pressure requirement is bypassed flow, blocking of all flow.
changes downstream of from port 1 to port 2. If the
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 240 bar (3500 psi)
Functional Symbols Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated flow 58 L/min (15 USgpm)
Cavity C–12–4
Variable
or fixed Standard housing materials Customized housings are
restrictor necessary for close-coupling
upstream the compensator and orifice
4 3 Temperature range -40° to 120°C (-40° to 248°F)
1 2 Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,36 kg (0.80 lbs)
Seal kits 9900335-000 Buna-N
9900336-000 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
0.350
0.300
EXTERNAL ORIFICE DIAMETER (INCH)
A
0.250
4 B
0.200
3 0.150 C
0.100
2
0.050
0.000
1 0 5 10 15
FLOW (GPM)
1 2 3 4 5 6
00 – None
(Only required if valve has
special features, omit if 00)
Dimensions
mm (inch) 31,7 (1.25) HEX
33,3 (1.31) I
Torque into aluminum
housing to 81-45 Nm 1 1/16 - 12 UNF - 2A THREAD
(60-75 ft. lbs)
90,2 (3.55)
20,6 (.810)
22,1 (.872)
23,7 (.935)
Description Operation
The PCS4-16 is a screw-in, This valve, when used with port 3. This is based port 2. If the priority port is
pressure compensator either a fixed or variable on whatever pressure deadheaded, the valve will
cartridge for the use orifice on port 4, maintains differential is chosen. All try to direct flow out of the
as a bypass or priority a constant flow out port 3, flow in excess of the priority port and shut off
flow control. regardless of pressure priority requirement is the bypass flow, blocking
changes downstream of bypassed from port 1 to of all flow.
0.400
Approx. orifice diameter - mm
10
0.350
A 8
0.300
B
3 0.250
C 6
0.200
0.150 4
2 0.100
2
0.050
0 0
0 3 6 9 12 15 18 21 24 27 30
1
Controlled priority flow , port 3 - USgpm (105 SUS oil @ 120˚ F)
1 2 3 4 5 6
00 – None
(Only required if valve has
special features, omit if 00)
Dimensions
mm (inch)
28,6
(1.12) 38,1 (1.50) hex
I
Torque into aluminum
housing to 108-122 Nm
(80-90 ft. lbs)
4
101,6
(4.00)
3
1
25,37 (0.999)
26,95 (1.061)
28,55 (1.124)
Description Operation
The PCS4-20 is a screw-in, This valve, when used with port 3. This is based on If the priority port is dead-
pressure compensator either a fixed or variable ori- whatever pressure differen- headed, the valve will try
cartridge for the use fice on port 4, maintains a tial is chosen. All flow in to direct flow out of the
as a bypass or priority constant flow out port 3, excess of the priority priority port and shut off
flow control. regardless of pressure requirement is bypassed the bypass flow, blocking of
changes downstream of from port 1 to port 2. all flow.
0.600 15
Approx. orifice diameter - mm
0.500 12
3
A
0.400
B 9
0.300
2 0.200 6
0.100 3
0 0
1 0 7 14 21 28 35 42 49 56 63 70
Controlled priority flow port 3,
- USgpm (105 SUS oil @ 120˚ F)
1 2 3 4 5 6
Dimensions
mm (inch)
41,3 I
Torque into aluminum (1.62) 47,6 (1.87) hex
housing to 128-155 Nm
(95-115 ft. lbs)
4
139,7
(5.50)
3
1
31,70 (1.248)
33,30 (1.311)
36,47 (1.436)
Description Operation
The FDC1-20 is a line This valve is used in the regardless of system pres- flows from ports 2 and 3
mounted pressure dividing mode. It will take sure to ports 2 and 4. and combine them into port
compensated, spool type, the inlet flow (port 1) and In the combining mode this 1 according to the ratio
flow divider/combiner split the flow according to valve will take the inlet specified.
valve. the ratio specified,
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Functional Symbol Rated inlet flow See model code
Fluids All general purpose hydraulic fluids such as:
2 3 MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13 F
Standard housing materials Aluminum
Weight cartridge only 2,6 kg. (5.75 lbs.)
1 Seal Kits 889639 Buna–N
889643 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
25
300 20
B
15
200
C 10
100
5
D
0
0 20 40 60 80 100
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
FDC1 – Flow divider/ CODE FLOW DIVISION% MAX. INLET FLOW 00 – None
combiner Port 4 Port 2 L/min (USgpm) (Only required if valve has
special features, omitted
2 Size 33 50 50 190,0 (50)
if “00”.)
20 – 20 Size 34 43 57 228,0 (60)
36 33 67 266,0 (70)
3 Seals 44 50 50 266,0 (70)
Blank– Buna-N 46 40 60 304,0 (80)
V – Viton®
66 50 50 380,0 (100)
4 Port size 88 50 50 380,0 (100)
16T – SAE 16 (light duty)
20T – SAE 20 (light duty)
(Available as a complete
assembly only.)
178,0 (7.00)
152,4 (6.00) 12,7 (0.50)
Dimensions
mm (inch)
63,5
Torque cartridge in housing (2.50)
128–155 Nm (95–115 ft. lbs) 31,7
(1.25) 2 3
Note
Minimum inlet flow should 31,7 31,7
not be less than 1/4 of 12,7
(1.25) (1.25)
maximum inlet flow for a (0.50)
given code.
101,6 104,0
(4.00) (4.10)
76,2
(3.00)
50,8
(2.00)
44,4 44,4
1 (1.75) (1.75) Ø10,0 (0.406 thru) (3 plcs.)
76,2
(3.00)
Description Operation
The FDC3-20 is a line This valve is used in the In the combining mode this port 1 according to the ratio
mounted, pressure dividing mode. It will take valve will take the inlet specified.
compensated, spool type, the inlet flow (port 1) and flows from ports 2 and 3
posi-traction cartridge split the flow to ports and combine them into
valve. 2 and 3.
Sectional View
A C D
Pressure drop - psi
350 25
B
300
20
250
200 15
150
10
100
50 5
0
0 20 40 60 80 100 120 140
Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6
Dimensions
12,7 (0.50) 152,4 (6.00) 12,7 (0.50)
mm (inch)
63,5
Note (2.50)
Minimum inlet flow should 31,7
not be less than 1/4 of (1.25) 2 3
maximum inlet flow for
a given code.
12,7 31,7 (1.25) 31,7 (1.25)
(0.50)
101,6
(4.00)
104,0
76,2 (4.10)
(3.00)
44,4 44,4
(1.75) (1.75) Ø10,3 (0.406 thru) (3 plcs.)
1
76,2
(3.00)
Quality Products and Vickers solenoid valves are Valve Features and • All exposed surfaces are
Innovative solutions offered with the widest Benefits zinc dichromate plated to
This catalog gives basic choice of flow paths and • Products in this catalog resist corrosion
specifications for the full position options to satisfy have been fatigue tested • All aluminum manifolds
line of Vickers screw-in most requirements. These for one million cycles at are gold anodized to
cartridge solenoid valves. options include: 132% or 10 million resist corrosion
Its purpose is to provide a • 2-way. 2-position, nor- cycles at 115% of rated • Reliable, economical and
quick, convenient reference mally open and normally pressure compact
tool when choosing Vickers closed spool and poppet • Rated flows up to 227
cartridge valves or design- valves • Manual override options
L/min (60 USgpm) are available on all sole-
ing a system using these • 3-way, 2-position spool
components. • Poppet and spool noid valves except SBV
valves designs series valves
Two pressure ratings are • 4-way, 2-position spool
shown for all products • Standard cartridge
valves Note
featured in this catalog - cavities
typical application pressure • 4-way, 3-position spool Solenoid valve coil
• All operating parts are
and fatigue pressure. The valves details are shown in
hardened steel, ground
typical application pressure section C.
and honed for long life
rating is the maximum and low leakage
recommended operating
• Cartridge design for
pressure for the valve in a
maximum flexibility and
given system. The fatigue
minimal manifold space
pressure rating is the
requirements
pressure for the valve to be
free for infinite life • Optional low-cost manu-
from metal fatigue. al override is available on
selected models
Coil Features The solenoid operated • Coils are rated for contin- An arc suppression diode
and Benefits directional valves in this uous duty molded into the coil is avail-
catalog are offered with a • Coils are interchangeable able as a standard option
choice of standard voltages for serviceability on DC coils. Also available,
and several types of electri- are explosion-proof coils
cal connections. For other • Variety of voltages and and cartridges that are CSA
coil ratings and connec- terminations approved and recognized by
Note tions, consult your Eaton • Coils offer a one-piece the US Underwriters
Solenoid valve coil representative. weather-proof encapsu- Laboratories.
details are shown in Standard AC coils are inter- lated design, eliminating
section C. nally rectified to supply the need for extra seals
them with DC current, • AC voltage coils are inter-
therefore they have no nally full-wave rectified
“inrush” current value. for 50 or 60 cycle (Hz)
applications
Protection of Internally The rectifiers used in these Protection is simple and supplying the rectified com-
Rectified Coils coils may require protection inexpensive. It consists of ponents. A single suppres-
from high voltage surges in installing a commercially sor will normally protect all
some electrical circuits con- available voltage surge sup- of the rectified components
taining highly inductive or pressor like the General in the circuit, as shown in
capacitive components. Electric MOV varistor the surge suppressor circuit
These include certain types V130LA20A for 115 volts AC diagram below.
of motors, solenoids, or the V250LA20A for 230
relays, and transformers. volts AC, across the AC line
Note AC line
Surge suppressor
Solenoid valve coil circuit diagram Voltage surge suppressor
details are shown in (MOV varistor)
section C. Rectified components
WARNING
• Application of
these products All voltage Switches
S or relay contacts only. Relay
beyond published perform- surge coils must be connected on the line
ance specifications may producing side of the surge suppressor.
cause valve malfunction components
which may result in per- must be No inductive or capacitive loads
installed on can be installed between the surge
sonal injury and/or dam-
this side of suppressor and rectified valves
age to the machine. suppressor. without additional precautions.
WARNING CAUTION
• Maintain 5-8 Nm • Coils may be
(4-6 ft. lbs) maxi- hot to touch
mum torque on valve tube if used in continuous
nut. Over tightening may applications.
cause valve or coil failure.
Description Operation
The SV13-10-O is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, this valve allows bi- flow is blocked from port 2
poppet type, normally open directional flow between to port 1, and is allowed
screw-in solenoid cartridge port 1 and port 2. from port 1 to port 2, when
valve. coil forces are overcome.
50
3
2
25
1
1
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
Application Note Port 1 to port 2 and port 2
This valve is pilot operated to port 1 de-energized
and requires a minimum
flow of 1-2 L/min (0.3- .5
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.
1 2 3 4 5 6 7 8 9 10 11
29,6
Dimensions (1.16)
mm (inch)
Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs)
Ø 38,9
Note (1.53)
When solenoid valve is
ordered as cartridge only, 22,2 (0.875) hex
nut is included.
57,8
(2.28)
Description Operation
The SV3-10-C is a 2-way, In the de-energized posi- In the energized position,
2-position, poppet-type, tion, flow is blocked from the poppet lifts to allow
normally closed screw-in port 2 to port 1 and free flow in either direction.
cartridge solenoid valve. flow is allowed from port 1
to port 2.
75 5
50
B 3
A
2
25
1
1
0
0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2 de-energized
B - Port 2 to port 1 energized
1 2 3 4 5 6 7 8 9 10
Dimensions
mm (inch)
0.875" – 14 Thd.
WARNING 31,7
• Maintain 5-8 Nm (1.25)
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may 1
cause valve failure. Ø 15,80 (0.622)
Description Operation
The SV13-12-O is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, flow can pass through flow is blocked from port 2
poppet type, normally open the valve from port 1 to to port 1, and allowed from
screw-in cartridge solenoid port 2, or from port 2 to port 1 to port 2 when the
valve. port 1. coil force is overcome.
15
200
11
150
A
2 100 7
B
50 3
1
0
0 5 10 15 20 25 30
Application Note
Flow - USgpm (105 SUS oil @ 120°F)
This valve is pilot operated A - Port 1 to port 2 de-energized
and requires a minimum B - Port 2 to port 1 de-energized
flow of 1-2 L/min (0.3 - 0.5
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.
1 2 3 4 5 6 7 8 9 10 11
Note
When solenoid valve is Ø 38,9
ordered as cartridge only, (1.53) 22,2 (0.875) hex
nut is included.
60,3
(2.37)
Description Operation
The SV3-12-C is a 2-way, In the de-energized posi- In the energized position,
2-position, poppet-type, tion, flow is blocked from the poppet lifts to allow
pilot-operated, normally port 2 to port 1 and free flow in either direction.
closed solenoid cartridge flow is allowed from port 1
valve. to port 2.
150 10
Pressure Drop - bar
Pressure Drop - psi
2
100
6
A
B
1 50
1
0
0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2 de-energized
B - Port 2 to port 1 energized
1 2 3 4 5 6 7 8 9 10
29,6
Dimensions
(1.16)
mm (inch)
Description Operation
The SV13-16-O is a 2-way, In the de-energized posi- flow is blocked from port 2
2-position, pilot operated, tion, this valve allows bi- to port 1 and allowed from
poppet type, normally open directional flow between port 1 to port 2, when the
screw-in cartridge solenoid port 1 and port 2. In the coil forces are overcome.
valve. energized position,
125 9
100 7
A B
2 75 5
50
3
1 25
1
0
0 5 10 15 20 25 30 35
Application Note Flow - USgpm (105 SUS oil @ 120°F)
This valve is pilot operated
and requires a minimum A - Port 2 to port 1 de-energized
flow of 1-2 L/min (0.3 - .5 B - Port 1 to port 2
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.
1 2 3 4 5 6 7 8 9 10 11
29,6
Dimensions (1.16)
mm (inch)
64,1
(2.52)
1.312"– 12 Thd.
WARNING 44,6
(1.76)
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may Ø 28,54 (1.124)
cause valve failure. 1
Description Operation
The SV2-20-C is a 2-way, In the de-energized posi- In the energized position,
2-position, poppet type, tion, flow is blocked from bi-directional flow is
pilot operated, normally port 2 to port 1 and free allowed between port 1
closed screw-in cartridge flow is allowed from port 1 and port 2.
solenoid valve. to port 2.
1 2 3 4 5 6 7 8 9
Note
Use J series, 23 W coils
Dimensions 29,6
with this solenoid valve.
mm (inch) (1.16)
Ø 38,9
Note (1.53)
When solenoid valve is
ordered as cartridge only,
coil nut is included. 19,0 (0.75) hex
63,5
(2.50)
1.625" – 12 Thd.
WARNING 57,2
(2.25)
• Maintain 5-8 Nm 2
(4-6 ft. lbs) maxi-
mum torque on valve tube
nut. Over tightening may 1
cause valve failure. Ø 36,47 (1.436)
Description Operation
The SV3-20-O is a 2-way, In the de-energized posi- flow is blocked from port 2
2-position, poppet type, tion, this valve allows bi- to port 1 and allowed from
pilot operated, normally directional flow between port 1 to port 2 when coil
open, screw-in cartridge port 1 and port 2. In the forces are overcome.
solenoid valve. energized position,
100 7
?
2
75 5
B ?
50
1 3
A
25
0
0 20 40 60
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9
Torque cartridge in
aluminum housing 128-155
Nm (95-115 ft. lbs)
Ø 38,9
Note (1.53)
When solenoid valve is
ordered as cartridge only,
coil nut is included. 19,0 (0.75) hex
76,2
(3.00)
Description Operation
The SV13-20-O is a 2-way, In the de-energized posi- flow is blocked from port 2
2-position, pilot operated, tion, this valve allows bi- to port 1 and allowed from
poppet type, normally open directional flow between port 1 to port 2, when the
screw-in cartridge solenoid port 1 and port 2. In the coil forces are overcome.
valve. energized position,
125 9
A
2 100 7
B
75 5
50
1 3
25
1
0
?
0 10 20 30 40 50 60
Application Note Flow - USgpm (105 SUS oil @ 120°F)
This valve is pilot operated
and requires a minimum A - Port 2 to port 1 de-energized
flow of 1-2 L/min (0.3 - .5 B - Port 1 to port 2
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.
1 2 3 4 5 6 7 8 9 10 11
29,6
(1.16)
Dimensions
mm (inch)
64,1
(2.52)
Description Operation
The SV15-10-O is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, flow from port 1 to flow is blocked from port 2
poppet type, normally open port 2 is restricted, while to port 1, and flow is
screw-in cartridge solenoid free flow is allowed from allowed from port 1 to port
valve. port 2 to port 1. 2, when coil forces are
overcome.
50 3
2 25
2
1 0 2 4 6 8 10 12
Flow - USgpm (105 SUS oil @ 120°F)
Application Note
This valve is pilot operated Port 2 to port 1 de-energized
and requires a minimum
flow of 1-2 L/min (0.3- 0.5
USgpm) in order to shift.
For operation at very low
flow conditions contact
your Eaton representative.
1 2 3 4 5 6 7 8 9 10 11
29,6
Dimensions (1.16)
mm (inch)
Torque cartridge in
steel housing 68-74 Nm
(50-55 ft. lbs)
Ø 38,9
Note (1.53)
When solenoid valve 22,2 (0.875) hex
is ordered as cartridge only,
nut is included.
57,8
(2.28)
0.875" – 14 Thd.
WARNING
• Maintain 5-8 Nm 31,7
(4-6 ft. lbs) maxi- (1.25)
mum torque on valve tube 2
nut. Over tightening may Ø 15,82 (0.623)
cause valve failure. 1
Description Operation
The SV11-10-C is a 2-way, 2- In the de-energized position, In the energized position,
position, pilot operated, this valve blocks flow from flow from port 1 to port 2
poppet type, normally port 2 to port 1 and free flow is restricted while free flow
closed, screw-in cartridge is allowed from port 1 to is allowed from port 2 to
solenoid valve. port 2. port 1.
1 2 3 4 5 6 7 8 9 10 11
1 Function 9
Connector types
6 Valve housing material
SV11 - Solenoid valve Blank - No coil
Blank - Cartridge only
G - ISO 4400 DIN 43650
2 S - Steel
Size Q - Spade terminals
10 - 10 size 7 W - Leadwire
Port Size N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Seal material Y - Amp JR (DC only)
0 Cartridge only D - Metripack 150 male
Blank - Buna-N
V - Viton® 2G 1/4” BSPP 02-175102 (DC only)
3G 3/8” BSPP 02-175103 J - Metripack 280 male
4 Style (DC only)
6T SAE 6 02-175100
C - Normally closed 8T SAE 8 02-175101 10 Coil series
5 Manual override option See section J for housing details. H - 10 series, 29 W
For coil part numbers and dimensions
Blank - No manual override
8 Voltage rating 24A - 24VAC see Section C.
M - Manual override
115A - 115VAC
For valve dimensions with manual 00 - No coil
230A - 230VAC 11 Special features
override option installed see page A-153. 12D - 12VDC
12B - 12VDC/w diode*
24D - 24VDC 00 - None
24B - 24VDC/w diode*
36D - 36VDC (Only required if valve
*Optional arc suppression diode.
has special features,
29,6
(1.16)
Dimensions
mm (inch)
Description Operation
The SV12-10-C is a 2-way, In the de-energized posi- In the energized position,
2-position, pilot operated, tion, this valve blocks flow flow from port 1 to port 2
poppet type, normally from port 2 to port 1 and is restricted while free flow
closed, screw-in cartridge free flow is allowed from is allowed from port 2 to
solenoid valve. port 1 to port 2. port 1.
75
A
50
3
B
2 25
1
1 0 2 4 6
?
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9 10 11
Dimensions
mm (inch)
Torque cartridge in
steel housing 68-75 Nm Ø 38,9
(50-55 ft. lbs) (1.53)
22,2 (0.875) hex
Note
When solenoid valve is
ordered as cartridge only,
coil nut is included.
57,8
(2.28)
Description Operation
The SV14-8-O is a 2-way, 2- In the de-energized posi- In the energized position,
position, spool type, direct tion, this valve allows bi- both ports are closed.
acting, normally open directional flow between
screw-in cartridge solenoid port 1 and port 2.
valve.
100
2 6
75
4
50
1
25 2
0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Flow - USgpm (105 SUS oil @ 120°F)
Port 2 to port 1 de-energized
Port 1 to port 2 de-energized
1 2 3 4 5 6 7 8 9 10 11
26,0
(1.02)
Dimensions
mm (inch)
Description Operation
The SV14-8-C is a 2-way, In the de-energized posi-
2-position, spool type, tion, flow is blocked in both
normally closed, screw-in directions. In the energized
cartridge solenoid valve. position, the spool lifts to
allow flow in either direc-
tion.
6
Pressure Drop - psi
4
2 50
2
25
1
0
0
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F)
Port 2 to port 1 or
port 1 to 2 (energized)
1 2 3 4 5 6 7 8 9 10 11
26,0
(1.02)
Dimensions
mm (inch)
Torque cartridge in
steel housing 34-41 Nm
(25-30 ft. lbs)
Ø 31,7
Note (1.25)
58,4
(2.30)
Description Operation
The SV14-10-O is a 2-way, In the de-energized posi- In the energized position,
2-position, spool type, tion, this valve allows bi- both ports are closed.
direct acting, normally open directional flow between
screw-in cartridge solenoid port 1 and port 2.
valve.
75 5
2 50
3
25
1
1
0 2 4 6
Flow - USgpm (105 SUS oil @ 120°F)
Port 2 to port 1 or
Port 1 to port 2 de-energized
1 2 3 4 5 6 7 8 9 10 11
Dimensions 29,6
mm (inch) (1.16)
Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs)
Ø 38,9
Note (1.53) 22,2 (0.875) hex
When solenoid valve is
ordered as cartridge only,
nut is included.
57,8
(2.28)
Description Operation
The SBV11-8-O is a 2-way, In the de-energized posi-
2-position, bi-directional, tion, flow is allowed in both
normally open, poppet directions. In the energized-
type, screw-in cartridge position, flow is blocked in
solenoid valve. both directions.
250
16
A Pressure Drop - bar
Pressure Drop - psi
200
12
2
150
8
1 100
B
4
50
0 0
1 3 5 7 9 11 13 15
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 2
B - Port 2 to port 1
1 2 3 4 5 6 7 8 9 10
Dimensions
mm (inch)
26,0
(1.02)
Torque cartridge in alu-
minum or steel housing
34-41 Nm (25-30 ft. lbs)
Note
Ø 31,7
When solenoid valve is (1.25) 15,8 (0.62) hex
ordered as cartridge only,
nut is included.
WARNING
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 58,4
mum torque on valve tube (2.30)
nut. Over tightening may
cause valve failure.
Description Operation
The SBV11-10-C is a In the de-energized posi-
2-way, 2-position, bi-direc- tion, flow is blocked in both
tional, normally closed, directions. In the energized
poppet type, screw-in position, flow is allowed in
cartridge, solenoid valve. both directions.
175 12
A - Port 1 to port 2
B - Port 2 to port 1
1 2 3 4 5 6 7 8 9 10
Note Ø 38,9
(1.53)
When solenoid valve is
ordered as cartridge only, coil 22,2 (0.87) hex
nut is included.
WARNING
• Maintain 5-8 Nm 57,8
(4-6 ft. lbs) maxi- (2.28)
mum torque on valve tube
nut. Over tightening may
cause valve failure.
25,4 (1.00) hex
WARNING
Aluminum housings 31,7
• 0.875"– 14 Thd.
can be used for 2 (1.25)
pressures up to 210
bar (3000 psi) Steel housings 1
must be used for operating Ø 15,81 (0.622)
pressures above 210 bar
(3000 psi).
Description Operation
The SBV11-10-O is a In the de-energized posi-
bi-directional, 2-way, 2-posi- tion, flow is allowed in both
tion, normally open, poppet directions. In the energized-
type, screw-in cartridge, position, flow is blocked in
solenoid valve. both directions.
12
150
8
100
2 50 4
1 0 4 8 12 16 20
Flow - USgpm (105 SUS oil @ 120°F)
Port 1 to port 2 or
port 2 to port 1
de-energized
1 2 3 4 5 6 7 8 9 10
Note
When solenoid valve is Ø 38,9
ordered as cartridge only, (1.53)
nut is included. 22,2 (0.87) hex
WARNING
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi-
mum torque on valve tube 57,8
nut. Over tightening may (2.28)
cause valve failure.
Description Operation
The SV11-8-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 1
spool type, screw-in car- from port 2 to port 1 while to port 3 while port 2 is
tridge solenoid valve. port 3 is blocked. blocked.
0 0
2
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F)
Flow - L/min (21,8 cSt oil @ 49°C)
1
0 2 4 6 8 10
Operating Limits 5000 A 350
B - Selector 1 to 2 and 1 to 3
3000 210
B
2000 140
70
1000
0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9 10 11
Dimensions 26,0
mm (inch) (1.02)
58,4
(2.30)
0.750" – 16 Thd.
WARNING 40,6 3
• Maintain 5-8 Nm (1.60)
(4-6 ft. lbs) maxi- 2
mum torque on valve tube
nut. Over tightening may Ø 14,2 (0.559)
Ø 15,8 (0.622) 1
cause valve failure.
Description Operation
The SV11-10-3 is a 3-way, 2- In the de-energized posi- In the energized position,
position, direct acting, tion, this valve allows flow flow is allowed from port 1
spool type, screw-in car- from port 2 to port 1 while to port 3 while port 2 is
tridge solenoid valve. port 3 is blocked. blocked.
B - Selector 1 to 2
3000 210
2000 140
B
1000 70
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9 10 11
29,6
Dimensions (1.16)
mm (inch)
Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs) Ø 38,9
(1.53)
Note 22,2 (0.875) hex
57,8
(2.28)
0.875" – 14 Thd.
46,0
(1.81) 3
WARNING
2
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- Ø 15,82 (.623) 1
mum torque on valve tube
nut. Over tightening may Ø 17,42 (.686)
cause valve failure.
Description Operation
The SV1A/B-12-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 1 to port 2 while to port 1 while port 2 is
tridge solenoid valve. port 3 is blocked. blocked.
6
80
2
5
60 4
B
1 3
40
2
20
1
0
0 1 2 3 4 5 6 7 8 9 10
Flow - USgpm
A - Port 3 to port 1 energized
B - Port 1 to port 2 de-energized
1 2 3 4 5 6 7 8 9 10 11
3 Size 10
7 Voltage rating 8 Connector types Coil special features
12 - 12 size 00 - No coil Blank - No coil Blank - No coil
12D - 12VDC G - ISO 4400 DIN 43650 00 - No special feature
4 Seal Material
24D - 24VDC W - Leadwire
Blank - Buna-N 24A - 24VAC N - Deutsch (DC only) 11 Special features
V - Viton® 110A - 110VAC For coil dimensions see Section C.
115A - 115VAC 00 - None
5 Style 12B - 12VDC/w diode* (Only required if valve
3P - 3 way, push type manual 24B - 24VDC/w diode* has special features,
overide *Optional arc suppression diode. omitted if “00.”)
SF - Soft shift
Torque cartridge in
aluminum housing 81-95 43,5 (1.71) 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL
MANUAL OVERDRIVE
Note
OVERDRIVE
When solenoid valve is Torque Torque
ordered as cartridge only, 22-26 LB-IN 22-26 LB-IN
coil nut is included.
1.25” 1.25”
HEX HEX
1.062” -
WARNING 12 Thread
Description Operation
The SV2A/B-12-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 2
spool type, screw-in car- from port 1 to port 3 while to port 1 while port 3 is
tridge solenoid valve. port 2 is blocked. blocked.
6
80
1
5
60
4
B
40 3
2
20
1
0
0 1 2 3 4 5 6 7 8 9
Flow - USgpm
A - Port 2 to port 1 energized
B - Port 1 to port 3 de-energized
1 2 3 4 5 6 7 8 9 10 11
3 Size 10
7 Voltage rating 8 Connector types Coil special features
12 - 12 size 00 - No coil Blank - No coil Blank - No coil
12D - 12VDC G - ISO 4400 DIN 43650 00 - No special feature
4 Seal Material
24D - 24VDC W - Leadwire
Blank - Buna-N 24A - 24VAC N - Deutsch (DC only) 11 Special features
V - Viton® 110A - 110VAC For coil dimensions see Section C.
115A - 115VAC 00 - None
5 Style 12B - 12VDC/w diode* (Only required if valve
3P - 3 way, push type manual 24B - 24VDC/w diode* has special features,
overide *Optional arc suppression diode. omitted if “00.”)
SF - Soft shift
Torque cartridge in
aluminum housing 81-95 43,5 (1.71) 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL
MANUAL OVERDRIVE
Note OVERDRIVE
When solenoid valve is Torque Torque
ordered as cartridge only, 22-26 LB-IN 22-26 LB-IN
coil nut is included.
1.25” 1.25”
HEX HEX
1.062” -
WARNING 12 Thread
Description Operation
The SV4A/B-12-3 is a 3-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 2 to port 1 while to port 2 while port 1 is
tridge solenoid valve. port 3 is blocked. blocked.
3 140 10
A 9
120
8
Pressure Drop - psi
2 7
100
6
80
1 5
60 B 4
40 3
2
20
1
0
0 1 2 3 4 5 6 7 8 9 10 11
Flow - USgpm
A - Port 3 to port 2 energized
B - Port 2 to port 1 de-energized
1 2 3 4 5 6 7 8 9 10 11
Torque cartridge in
aluminum housing 81-95 43,5 (1.71) 45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL
MANUAL OVERDRIVE
Note
OVERDRIVE
When solenoid valve is Torque Torque
ordered as cartridge only, 22-26 LB-IN 22-26 LB-IN
coil nut is included.
1.25” 1.25”
HEX HEX
1.062” -
WARNING 12 Thread
Description Operation
The SV12-8-4 is a 4-way, In the de-energized position
2-position, direct acting, all ports are blocked. In the
spool type, screw-in car- energized position, flow is
tridge solenoid valve. allowed from port 3 to port
4 and from port 2 to port 1.
Performance Characteristics
Cartridge only
2
100 280
4000
Pressure - bar
Pressure - psi
A 6
1 75
3000 210
B 4
50 140
2000
2 B
25 70
1000
0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 0 0
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9 10 11
29,6
Dimensions (1.16)
mm (inch)
Torque cartridge in
aluminum or steel housing Ø 38,9
34-41 Nm (25-30 ft. lbs) (1.53)
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi-
mum torque on valve tube
nut. Over tightening may
cause valve failure.
Description Operation
The SV3-10-4 is a 4-way, In the de-energized posi- In the energized position all
2-position, direct acting, tion, port 3 is open to port 4 ports are blocked.
spool type, screw-in car- and port 2 is open to port 1.
tridge solenoid valve.
60
3 4
45
B 3
A
2 30
2
15 1
1
0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 3 to port 4
B - Port 1 to port 2
1 2 3 4 5 6 7 8 9
Dimensions 29,6
mm (inch) (1.16)
Torque cartridge in
aluminum housing 47-54
Nm (35-40 ft. lbs) Ø 38,9
(1.53)
Description Operation
The SV4-10-4 is a 4-way, In the de-energized posi- In the energized position
2-position, direct acting, tion, flow is allowed port 3 is open to port 4 and
spool type, screw-in car- between port 1 and port 4 port 2 is open to port 1.
tridge solenoid valve. while port 2 and port 3 are
blocked.
60
4
3
45
3
A B
30 2
2
15 1
1 0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 3 to port 4
B - Port 1 to port 2
1 2 3 4 5 6 7 8 9
Torque cartridge in
aluminum housing 47-54
Nm (35-40 ft. lbs) Ø 38,9
(1.53)
0.875" – 14 Thd.
4
62,0
(2.44)
3
WARNING
Maintain 5-8 Nm 2
•
(4-6 ft. lbs) maxi-
mum torque on valve tube 1
Ø 15,80 (0.622)
nut. Over tightening may
cause valve failure. Ø 17,40 (0.685)
Ø 18,97 (0.747)
Description Operation
The SV5-10-4 is a 4-way, In the de-energized posi-
2-position, direct acting, tion, all ports are blocked.
spool type, screw-in In the energized position
cartridge solenoid valve. port 2 is open to port 3 and
port 1 is open to port 4.
75 5
4
60 4
3 A
45 3
B
30 2
2
15 1
1 0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 1 to port 4
B - Port 3 to port 2
1 2 3 4 5 6 7 8 9
Torque cartridge in
aluminum housing 47-54 Ø 38,9
Nm (35-40 ft. lbs) (1.53)
19,0 (0.75) hex
Note
When solenoid valve is
ordered as cartridge only,
coil nut is included. 57,1
(2.25)
0.875" – 14 Thd.
4
62,0
(2.44) 3
WARNING
Maintain 5-8 Nm 2
•
(4-6 ft. lbs) maxi-
mum torque on valve tube Ø 15,80 (0.622) 1
nut. Over tightening may
Ø 17,40 (0.685)
cause valve failure.
Ø 18,97 (0.747)
Description Operation
The SV2A/B-12-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, all ports are blocked. port 3 is open to port 4 and
spool type, screw-in car- port 2 is open to port 1.
tridge solenoid valve.
6
80 A
4
5
60 B
Pressure Drop - bar
Pressure Drop - psi
4
3
3
40
2
2
20
1 1
0
0 1 2 3 4 5 6 7 8 9 10 11
Flow - USgpm
A - Port 2 to port 1
B - Port 3 to port 4
1 2 3 4 5 6 7 8 9 10 11
85,4 (3.36)
84,9 (3.34)
1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread
1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-129
SV3A/B-12-4
4-way, 2-position, spool
type solenoid valve
Description Operation
The SV3A/B-12-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, port 3 is open to port all ports are blocked.
spool type, screw-in car- 4 and port 2 is open to port
tridge solenoid valve. 1.
10
140
4 9
A
120
8
7
Pressure Drop - bar
100
Pressure Drop - psi
3
6
80
5
B
2 60
4
40 3
1 2
20
1
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow - USgpm
A - Port 3 to port 4
B - Port 2 to port 1
1 2 3 4 5 6 7 8 9 10 11
85,4 (3.36)
84,9 (3.34)
1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread
1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-131
SV5A/B-12-4
4-way, 2-position, spool
type solenoid valve
Description Operation
The SV5A/B-12-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, all ports are blocked. port 3 is open to port 2 and
spool type, screw-in car- port 4 is open to port 1.
tridge solenoid valve.
100
90 6
2 80 A 5
70
60 4
1 50 B 3
40
30 2
20
1
10
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow - US gpm (105 SUS Oil @ 120°F)
A - Port 3 to port 2
B - Port 4 to port 1
1 2 3 4 5 6 7 8 9 10 11
85,4 (3.36)
84,9 (3.34)
1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread
1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-133
SV7A/B-12-4
4-way, 2-position, spool
type solenoid valve
Description Operation
The SV7A/B-12-4 is a 4-way, In the energized position, In the de-energized position,
2-position, direct acting, port 3 is open to port 4 and port 3 is open to port 2 and
spool type, screw-in car- port 2 is open to port 1. port 4 is open to port 1.
tridge solenoid valve.
100
2 90 6
80
A
5
70
1 60 B 4
50
3
40
30 2
20
1
10
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12
Flow - US gpm (105 SUS Oil @ 120°F)
A - Port 2 to port 1, port 3 to port 4
B - Port 3 to port 4, port 3 to port 2
1 2 3 4 5 6 7 8 9 10 11
Torque cartridge in
aluminum housing 81-95 43,5 (1.71)
45,9 (1.81)
Nm (60-70ft. lbs)
MANUAL MANUAL
OVERDRIVE OVERDRIVE
Note Torque
Torque 22-26 LB-IN
When solenoid valve is 22-26 LB-IN
ordered as cartridge only,
coil nut is included.
85,4 (3.36)
84,9 (3.34)
1.25” 1.25”
HEX HEX
1.062” - 1.062” -
12 Thread 12 Thread
1
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A-135
SV11-8-4/4M
4-way, 2-position spool
type solenoid valve,
350 bar
Description Operation
The SV11-8-4 is a 4-way, In the de-energized posi- In the energized position,
2-position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 3 to port 2 and to port 4 and from port 2 to
tridge solenoid valve. from port 4 to port 1. port 1.
Performance Characteristics
Cartridge only
Flow - L/min (21,8 cSt oil @ 49°C) Flow - L/min (21,8 cSt oil @ 49°C)
2 0 2 4 6 8 10
0 2 4 6 8 10 5000 350
125 A
1 280
Pressure Drop - bar
8
Pressure Drop - psi
4000
100
Pressure - bar
Pressure - psi
A 6 3000 210
75
B
B 2000 140
50 4
C 70
25 2 1000
0 0 0
0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
0 0.5 1.0 1.5 2.0 2.5 3.0
Flow - USgpm (105 SUS oil @ 120°F)
Flow - USgpm (105 SUS oil @ 120°F)
1 2 3 4 5 6 7 8 9 10 11
26,0
(1.02)
Dimensions
mm (inch)
Torque cartridge in
aluminum or steel housing Ø 31,7
34-41 Nm (25-30 ft. lbs) (1.25)
15,8 (0.62) hex
Note
When solenoid valve is
ordered as cartridge only, 58,4
nut is included. (2.30)
0.750"– 16 Thd.
4
54,5
WARNING (2.15)
3
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- 2
mum torque on valve tube Ø 12,6 (0.500)
nut. Over tightening may Ø 14,2 (0.559) 1
cause valve failure. Ø 15,8 (0.622)
Description Operation
The SV11-10-4 is a 4-way, 2- In the de-energized posi- In the energized position,
position, direct acting, tion, this valve allows flow flow is allowed from port 3
spool type, screw-in car- from port 3 to port 2 and to port 4 and from port 2 to
tridge solenoid valve. from port 4 to port 1. port 1.
4 125 9
A
100 7
3
75 5
2 B
50 3
25
1 1
0
0 2 4 ?6
Flow - USgpm (105 SUS oil @ 120°F)
A - Port 3 to port 2
B - Port 4 to port 1
1 2 3 4 5 6 7 8 9 10 11
SV11 - Solenoid valve Blank - Omit for cartridge only Blank - No coil
S - Steel G - ISO 4400 DIN 43650
2 Size Q - Spade terminals
7 Port Size W - Leadwire
10 - 10 size
N - Deutsch (DC only)
CODE PORT SIZE HOUSING NUMBER
3 Y - Amp JR (DC only)
Seal material 0 Cartridge only D - Metripack 150 male
Blank - Buna-N 2G 1/4” BSPP 02-175139 (DC only)
V - Viton® J - Metripack 280 male
3G 3/8” BSPP 02-175140
(DC only)
4 Style 6T SAE 6 02-175137
4 - 4-way, 2-position 8T SAE 8 02-175138 10 Coil series
Torque cartridge in
steel housing 68-75 Nm
(50-55 ft. lbs) Ø 38,9 22,2 (0.875) hex
(1.53)
Note
When solenoid valve is
ordered as cartridge only,
57,8
nut is included.
(2.28)
0.875" – 14 Thd.
4
61,8
(2.43) 3
WARNING
2
• Maintain 5-8 Nm
(4-6 ft. lbs) maxi- Ø 16,0 (.63)
mum torque on valve tube Ø 17,6 (.70) 1
nut. Over tightening may Ø 19,2 (.76)
cause valve failure.
This section gives basic tive, 2 way, pressure com- spool type, screw-in pres- and honed for long life
specifications for the com- pensated flow regulator. sure reducing/relieving valve. and low leakage
plete line of Vicker’s screw-in The ERV1-10 is an electric, It is capable of handling flows • Designed for maximum
proportional control valves. proportionally controlled, from 0-30 L/min (0-8 USgpm) flexibility and minimal
Its purpose is to provide a internally pilot operated, at set pressures from 35-207 space requirements
quick, convenient reference spool type screw-in relief bar (500-3000 psi).
tool when choosing propor- • All exposed cartridge sur-
valve. It is capable of han- Vickers proportional pressure faces are zinc dichromate
tional valves or when design- dling flows from 3,8-60,0 and flow control valves are
ing a system using these plated to resist corrosion
L/min (1-15 USgpm) at designed to be easily con-
components. pressures from 35-210 bar trolled by the simplest of DC • Reliable, economical and
The EPV10 has several out- (500-3000 psi). Also avail- electrical devices such as a compact
standing performance fea- able is an ERV1-16 which is 12 volt battery and a poten- • Rated flows up to 160
tures which give it a unique capable of handling flows tiometer. L/min (42 USgpm)
position in the screw-in car- from 7,6-132 L/min. (2-35 Varying the voltage at the • Optional nose-in, side-out
tridge valve market. Valve USgpm) at pressures from coil is one of the simplest or side-in, nose out flow
gain linearity, flow force 35-210 bar (100-500 psi). means of control available. direction (EPV16 series)
pressure compensation char- The ERV2-10 is a low flow Any of the Vickers DC coils
acteristics above 20 bar (300 electric proportionally con- will work on most of these
psi) and low internal leakage. Coil Features and Benefits
trolled relief valve similar to valves simply by varying the
The EPV16 is a proportionally the ERV1-10. This valve is voltage between 0 and 75% The valves in this catalog are
controlled two-way poppet rated for flows from 0,2-2,8 of the rated coil voltage. It offered with a choice of two
type valve. The main poppet L/min (0.05-0.75 USgpm) should be noted that as the or three standard voltages
amplifies a small flow and pressures up to 35 bar operating temperature of a and several types of electri-
through the pilot circuit and (500 psi). coil increases, the solenoid cal connections. For other
is comparable to a transistor. force decreases. Therefore if coil ratings and connections,
The ERV3-10 is a low flow consult your Eaton applica-
As the transistor uses small electric proportionally con- the voltage is held constant
currents to control larger cur- as the coil heats up then tions engineer.
trolled relief valve similar to
rents, the hydraulic valve the ERV2-10. This valve is valve pressure (or flow) will • Variety of voltages and
transistor or VALVISTOR rated for flows up to 0,8 change. terminations
uses the pilotflow to control L/min (0.20 USgpm) and The IRV1 is a proportionally • Coils are interchangeable
the main stage flow with pressures up to 207 bar controlled poppet type, relief for serviceability on the
servo-like response flow to (3000 psi). valve, with an inverse func- EPV10 and EPV16. Coils
control. tion. This valve is capable of are interchangeable for
The EPRV2-8 is an electric,
The ESV1 is a proportional proportionally controlled, handling flows up to 1 L/min serviceability on the
two-way, presssure compen- direct acting spool type, (0.25 USgpm) and press- ERV1-10, EPV1-16, EPRV1-
sated, poppet type flow con- screw-in pressure sures up to 210 bar (3000 10 and EPRV1-16
trol valve. The valve is avail- reducing/relieving valve. It is psi). • Compact, one-piece
able in 8, 10, and 12 sizes, capable of handling flows Electrical current controls weather-proof encapsu-
both normally open or nor- from 0-7,6 L/min (0-2 with PWM are recomended lated design. Eliminates
mally closed in the de-ener- USgpm) at set pressures for all Eaton proportional need for extra seals
gized position. from 0-22 bar (0-320 psi). valves. • An arc suppression diode
The EFV1 is a proportionally The EPRV1-10 is an electric, Closed-loop electrical control molded into the coil is
controlled two-way, spool proportionally controlled, with feedback from the available as a
type flow control valve. internally pilot operated, parameter to be monitored standard option
Technically the valve is not spool type, screw-in pres- will provide the most accu- on ERV, EPRV
pressure compensated, but sure reducing/relieving valve. rate control.
• and EFV valves
it is partiall flow force pres- It is capable of handling
sure compensated. flows from 0-7,6 L/min (0-2 Valve Features and Fluid Cleanliness
The EFV2 is a three port, USgpm) at set pressures Benefits Proper fluid condition is
pressure compensated, pro- from 14-35 bar (200-500 psi). • Products in this catalog essential for long and
portional flow control valve. Also available is an ERV1-16 have been fatigue tested satifactory life of hydraulic
The valve can be used as a which is capable of handling to one million cycles components and systems.
priority flow regulator, with flows from 0-38 L/min (0-10 at 132% or 10 million Hydraulic fluid must have
regulated flow being sup- USgpm) at set pressures cycles at 115% of rated the correct balance of
plied to port 3 and excess from 14-35 bar (200-500 psi). pressure cleanliness, materials, and
flow being by-passed to port The EPRV3-10 is an electric, additives for protection
2. If port 2 is blocked the • All operating parts are
proportionally controlled, hardened steel, ground against wear of compo-
valve functions as a restric- internally pilot operated, nents, elevated viscosity,
and inclusion of air.
1 1
Description 2 Operation
2
The ERV1-10 is an electric, This valve remains closed port 1, overcoming the
proportionally controlled, between port 1 and 2 until electrical force and open-
internally pilot operated, spool the predetermined pressure ing the spool to allow
type, screw-in relief valve. setting has been reached at flow from port 1 to port 2.
2 2
1 1
150 150
2000 1 2000
4
4
100 50 50
100
10 5 15 10 15 10 5 15 10 15
Pressure Drop - bar
5
Pressure Drop - psi
3000 100 5
200
150
Flow - USgpm
Flow - USgpm (105 SUS oil @ 120°F) (105 SUS oil @ 120°F) Flow - USgpm (105
Flow - USgpm (105 SUS oil @ 120°F)6 SUS oil @ 120°F)
2000
4
150
100 50
2000
4
1000
B-50 100 V-VLOV-MC001-E4 September, 2007 50
EATON Vickers Screw-In Cartridge Valves 2
50
1000 2
Model Code ERV1-10
1 2 3 4 5 6 7 8
nse Volts
bar psi Step response Volts
9Dimensions Performance bar psi Step response Volts
Input voltage
voltage
6Torque Cartridges only 210 3000 9
voltage
cartridge Zero outlet 140 2000 6
3in aluminum pressure 140 2000 6 Input
housing Input 38,9
Ø 38,9 70 1000 3
47-54 Nm 70 1000 (1.53
38,
0.3 seconds
0.4 (35-40 (1.53) 3
ft. lbs) (1.53
time 19,0 (0.75) Hex 0
0 0 0.1 0.2 0.3 0.4 seconds
0 0.1 0.2 time
Response 0.3 0.4 seconds
Response time
gain
280 73,0
(2.87) Pressure gain
73
Pressure - bar
Pressure
Pressure
Pressure
2000 140
70 33,3 2000 140
(1.31) 0.875"-14 Thd.
1000 70 33
2 1000 70 (1.
3
6 9 volts (1.
1
25C (77F) Ø 15,80 (0.622) 0 3 6 9 volts
Valve is shown with “W” coil.
Input voltage @ 25°C (77°F) 9 volts
0 3 6
Input voltage @ 25°C (77°F)
Description Operation
The ERV1-16 is an electric, This valve remains closed port 1, overcoming the
proportionally controlled, between port 1 and 2 until electrical force and
internally pilot operated, spool the predetermined pressure unseating the spool to
1type, screw-in relief valve. setting has been reached at allow flow from port 2.
2
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
1 Typical application pressure (all ports) 3,5 - 210 bar (50 - 3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
1 2
Rated flow 7,6 - 132,0 L/min (2 - 35 USgpm)
2 Cavity C-16-2
Standard housing materials Aluminum
Temperature range -40° to 120°C (-40° to 248°F)
Sectional View 2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/116/13
Weight cartridge and coil 1 0,44 kg (0.98 lbs)
Seal kits 565810 (Buna-N)
889609 (Viton®)
Viton is a registered trademark of E.I. DuPont
Pressure - psi
Pressure - bar
2 2000 140
1 1000 70
2
2 0 0
10 20 30 40 50
1 Flow - USgpm (105 SUS oil @ 120°F)
1
Flow - L/min (21,8 cSt oil @ Pressure
49°C) override, Flow - L/min (21,8 cSt oil @ 49°C)
40 80 120 de-energized
160 40 80 120 160
3000 210 100 7
Pressure - psi
Pressure - psi
Pressure - bar
Pressure - bar
2000 Flow - L/min (21,8 cSt oil @ 49°C) 140 Flow - L/min (21,8 cSt oil @ 49°C)
60 4
40 - L/min
Flow 80 (21,8
120 cSt160
oil @ 49°C) 40 - L/min
Flow 80 (21,8
120 cSt160
oil @ 49°C)
3000 210 100 7
1000 40 80 120 160
70 40 80 120 160
3000 210 30 100 2 7
Pressure - psi
Pressure - psi
Pressure - bar
Pressure - bar
2000 140
Pressure - psi
Pressure - psi
Pressure - bar
Pressure - bar
0 0 060 0 4
200010 20 30 40 50 140 10 20 30 40 50
60 4
1000Flow - USgpm (105 SUS oil @ 120°F) 70 30
Flow - USgpm (105 SUS oil @ 120°F)
2
1000 70 30 2
0 0 0 0
10 20 30 40 50 10 20 30 40 50
0 0 0 0
B-52 Flow - USgpm
EATON(105
20SUSScrew-In
10 Vickers oil
30 @ 120°F)
Cartridge Valves V-VLOV-MC001-E4 September, 2007 Flow - USgpm (105 SUS oil @ 120°F)
40 50 10 20 30 40 50
Flow - USgpm (105 SUS oil @ 120°F) Flow - USgpm (105 SUS oil @ 120°F)
Model Code ERV1-16
1 2 3 4 5 6 7 8
onse Volts
bar
bar psi
psi Step response
Step response Volts
Volts
9Dimensions Performance
Input voltage
29,6
mm (inch) Characteristics
(1.16)
6Torque Cartridges only 210
210 3000
3000 99
voltage
Inputvoltage
cartridge
Pressure
Zero outlet
Pressure
140 2000
3in aluminum pressure 140 2000 66
housing Ø 38,9 Input
108-122 Nm 70 1000 3
0.3 seconds
0.4(80-90 (1.53) 70 1000 33 38
(1.
ft. lbs) (1.
time 19,0 (0.75)
Hex Torque 0
0 0
0 0.1
0.1 0.2
0.2 0.3
0.3 0.4
0.4 seconds
seconds
to 5-8 Nm
Response time
Response time
gain
280 79,0
(3.1)
Pressure gain
gain
Pressure - bar
210 Pressure
3600
3600 280
280
bar
psi
Pressure
3 3
2 2
1 1
3
3
2 Pressure override, energized Pressure override, de-energized
2 Flow - L/min
Flow -(28,0
L/mincSt
(28,0 cSt
oil @ oil @ 49°C)
49°C) Flow (28,0
Flow - L/min - L/min (28,0
cSt oil @cSt oil @ 49°C)
49°C)
1 38 3819 190 019 19
38 38 38 3819 19 0 0 19 19
38 38
600 42 50 50
1600 42
3 3
28 28
Pressure - psi
Pressure - psi
400
Pressure - bar
Pressure - bar
Pressure - psi
Pressure - psi
400
Pressure - bar
Pressure - bar
Pressure - psi
400 10
- bar- bar
Pressure - bar
Flow - USgpm
Flow - USgpm (135 SUS oil @ 120°F)
(135 SUS Flow - USgpm (135
oil SUS oil @ 120°F)
28 oil @ 120°F) 25 Flow - USgpm (135 SUS @ 120°F)
Pressure - bar
Pressure - psi
Pressure
400 2
Pressure
200 14
Pressure
Pressure
15 1
200
B-60 14 V-VLOV-MC001-E4 September, 2007
EATON Vickers Screw-In Cartridge Valves
0 0
0 0
Model Code EPRV1-16
1 2 3 4 5 6 7 8
voltage
Inputvoltage
3 cartridge Zero outlet (0(
28
28 400
400 66
in aluminum pressure
housing 3
Reduced
14 200
Input 38
14 200 33 (1
0,3 0,4 108-122 Nm
seconds (1.
(80-90 ft. lbs)
time
00
00 0,1 0,2
0,1 0,2 0,3
0,3 0,4 seconds
0,4 seconds
gain Response time
Response time
34
Pressure - bar
Pressuregain
Pressure gain
500 34
34
500
bar
psi
Pressure--bar
Pressure--psi
17
Pressure
Pressure
250 17
17
250
6 9 volts 1
25C (77F)
00 33 66 volts
99 volts
Valve is shown with “W” coil. Inputvoltage
voltage@@25°C
25°C(77°F)
(77°F)
Input
2
Weight cartridge only 1 kg (2.2 lbs)
Filtration 70 - 210 bar (1000 - 3000 psi) Cleanliness code 17/115/12
1 2 210+ bar (3000+ psi) Cleanliness code 15/113/11
2
1 Standard housing materials Aluminum or steel
1 Typical hysteresis Less than 4% of rated current @ 10 bar
pressure drop – Pulse Width Modulated (PWM)
EPV16-B Side-in, nose-out
Internal leakage @ 140 bar (2000 psi) EPV16A 50 cm3/min maximum
and oil viscosity 30cSt EPV16B 10 cm3/min maximum
Oil viscosity range 10 - 800 cSt
Nominal supply voltage 12 or 24 VDC
Threshold current Adj from 350 - 600 mA (12 VDC)
Adj from 175 - 250 mA (24 VDC)
Coil current for maximum flow 0.7 amps @ 24 VDC
1.4 amps @ 12 VDC
Recommended PWM frequency 100 -200 Hz application dependent, 150 Hz typ
Coil resistance @ 20°C (68°F) 12V-6.5Ω/24V-25.0Ω
2
Power consumption @ rated current 12V-12.8 watts
1 and 20°C coil temperature 24V-12.8 watts
Cartridge seal kit 02-154069 (Buna-N)
2
2
1
1
1 2 3 4 5 6 7 8 9 10 11
2 2
1 1
EPV16-A 2 Note
Nose-in, side-out When stand alone housings
mm (inch) are used, the following
guidelines apply:
• EPV16-A: Port 3 is to be
1 plugged.
Screw type • EPV16-B: Port 3 is to
actuator (shown) 3 be connected to port 1
mm hex socket in order to provide the
Screw type Screw type
actuator (shown) 3 actuator (shown) 3 required feedback
mm hex socket mm hex socket flow path. Ø 43,5 (1.71)
27,3 (1.07)
Ø 43,5 (1.71) Ø 43,5 (1.71)
27,3 (1.07) 27,3 (1.07)
129,0 124,7
(5.07) (4.90) 1.312"
-12 Thd.
1.312" 1.312"
2 -12 Thd. 2 -12 Thd.
185,3 67,9 181,0
(7.29) (2.67) (7.12)
2 1 2 2 1 2
38,1 Hex (1.50) Ø 25,4 (1.00)
1 1
With manual actuator 1 1
No manual actuator
38,1 Hex (1.50) 38,1 Hex (1.50) Ø 25,4 (1.00) Ø 25,4 (1.00)
1.312"
With manual actuator With manual actuator No manual actuator
-12 Thd. No manual actuator
Valves are shown with “U” coil. See Section C for coil information.
2 Torque cartridge in aluminum housing 108-122 Nm (80-90 ft. lbs) 2
Torque cartridge in steel housing 136-149 Nm (100-110 ft. lbs)
1 1
38,1 Hex (1.50) Ø 25,4 (1.00)
With manual actuator No manual actuator
1 1
3
3 3
2 B
2 2
EPV16-B Required external
1
Side-in, nose-out connection with standard
mm (inch)
C-16-3S cavity
3
Screw type 2
actuator (shown) 3
ScrewScrew mm
type hex socket
type
actuator
actuator (shown)
(shown) 3 3
mmmm hex hex socket
socket Ø 43,5 (1.71)
27,3 (1.07)
27,327 ,3 (1.07)
(1.07) Ø 43,5
Ø 43,5 (1.71)
(1.71)
129,0
Screw type (5.07)
actuator (shown) 3 124,7
mm hex socket 129,0
129,0 (4.90)
(5.07)
(5.07) 124,7124,7
(4.90)
(4.90)
27,3 (1.07) 185,3Ø 43,5 (1.71) 67,9
(7.29) (2.67) 181,0
(7.12)
185,3
185,3 67,967,9
(7.29)
(7.29) (2.67)
(2.67) 181,0
181,0
(7.12)
(7.12)
129,0
(5.07) 124,7
3 1.312"-12 Thd.
(4.90) 3
3 3 1.312"-12
1.312"-12 Thd.Thd.
2 3 3 2
185,3 67,9
(7.29) (2.67) 181,0
2 12 (7.12) 2 12
38,1 Hex (1.50) Ø 25,4 (1.00)
1 1 1 1 Ø 28,6 (1.12)
38,138,1
HexHex (1.50)
(1.50) Ø 25,4
Ø 25,4 (1.00)
(1.00)
With manual actuator No Ø
manual actuator
Ø 28,6
28,6 (1.12)
(1.12)
3 1.312"-12 Thd.
3
WithWith manual
manual actuator
actuator No manual
No manual actuator
actuator
2 2
1 1
For EPV16-B (flow 2 to 1), Port 3 must be connected to Port 1 externally to the cartridge,
38,1 Hex (1.50)either by passages in the cavity block or external plumbing.ØWhen
25,4purchased
(1.00) with undercut
body, this connection is included in the body and Port 3 is not machined.
Ø 28,6 (1.12)
A separate external port connection is not required for EPV16-A (flow 1 to 2).
With manual actuator No manual actuator
EPV16-A-**-S-5C-**-D-(*)-*-12
CETOP 5 Interface
mm (inch)
.250-20 UNC x 2.500"
socket head cap screw
(BoltUNC
.250-20 x 2.500"
Kit 255634) 71,6 (2.82)
276,0 (10.9) Required for removal
M6socket head cap
x 60 socket headscrew
cap 71,6 (2.82)
219,7 (8.65)
276,0 (10.9) Required for removal (BoltKit
screw (Bolt Kit689623)
255634)
M6 x 60 socket head cap 69,5 (2.74)
219,7 (8.65)99,5 (3.92) screw (Bolt Kit 689623) 69,5 (2.74)
99,5 (3.92)
60,0
(2.38) 51,0
60,0
(2.38) (2.01)
51,0
(2.01)
ISO-4401-AC-05-4-A (NFPA D05)
mounting surface
ISO-4401-AC-05-4-A (NFPA D05)
mounting surface 22,8 (0.89)
P
22,8 (0.89)
P 11,7 (0.46)
B ? A
11,7 (0.46)
Tb B ? A Ta
Tb Ta P A B Ta Tb
P A B Ta Tb
?
Ø 6,96/6,85 thru 4 holes
?
Ø 6,96/6,85 thru 4 holes
EPV16-B-**-S-5C-**-D-(*)-*-12
CETOP 5 Interface
mm (inch)
PA B Tb Ta
P removal
276,0 (10.9) Required for A B Tb Ta
219,7Required
276,0 (10.9) (8.65) for removal
71,6 (2.82) .250-20 UNC x 2.5"
69,5 (2.74) socket head cap screw 99,5 (3.92) 219,7 (8.65)
71,6 (2.82) .250-20
(Bolt UNC x 2.5"
Kit 255634)
socket 99,5 (3.92)
69,5 (2.74) M6 x 60head caphead
socket screw
cap
(Bolt Kit
screw 255634)
(Bolt Kit 689623)
60,0 M6 x 60 socket head cap
51,0 (2.38) screw (Bolt Kit 689623)
60,0
(2.01) (2.38)
51,0
(2.01)
ISO-4401-AC-05-4-A
(NFPA D05) 22,8 (0.89) 11,7 (0.46)
ISO-4401-AC-05-4-A
mounting surface
(NFPA D05) 22,8 (0.89)
P 11,7 (0.46)
mounting surface
P
B ? A
Note Tb B ? A Ta
CETOP 5 Seal Kit 02- Tb Ta
319667
Ø 6,96/6,85 thru 4 holes
Ø 6,96/6,85 thru 4 holes
Pressure Differential
Pressure Differential -- psi
psi
Pressure Differential - psi B
–2000
–3000
–2500
–3500
–1500
–4000
–2000
–3000
–2500
–3500
–1500
–4000
–500
–500
–2000
–3000
–2500
–3500
–1500
–4000
–0
–500
–0
II H G
–0
150
150 H G
Typical pressure
150 I H G 140
140 COMMAND CURRENT
140
compensation 120 FF 12V 24V
120 F
120 A– 600 mA 300mA
100
100 EE B– 700 mA 350mA
%*
100
Flow%*
80 E
Flow %*
80 C– 800 mA 400mA
80
Flow
60
60 D D– 900 mA 450mA
60 D
40 D E– 1000 mA 500mA
40 C
C
40 C B F– 1100 mA 550mA
20
20 B
20 B A
A G– 1200 mA 600mA
0 A H– 1300 mA 650mA
0
0
260
280
200
220
240
140
I– 1400 mA 700mA
20
40
60
80
100 00
100
160
180
120
260
280
200
220
240
140
12020
40
60
80
100
160
180
120
260
280
200
220
240
140
20
40
60
80
0
160
180
Pressure Differential
Pressure Differential -- bar
bar
Pressure Differential - bar
** Flow
Flow interims
interims of
of %
% for each poppet
for each poppet size
size
* Flow interims of % for each poppet size
E
E
E DC
D
DC C
Typical metering 150
150 B PRESSURE DIFFERENTIAL
150 140
140 B B
performance140 A– 10 bar 150 psi
120
120 UPPER
UPPER TOLERANCE OF FLOW
TOLERANCE OF FLOW B– 20 bar 300 psi
120 UPPER TOLERANCE OF FLOW A
100
100 A A C– 50 bar 700 psi
100 NOMINAL FLOW (LOWER
(LOWER TOLERANCE)
TOLERANCE)
%*
80
NOMINAL FLOW (LOWER TOLERANCE)
Flow %*
80 80
E– 200 bar 3000 psi
Flow
60
60
60
40 40
40
20 20
20
0 0
0
(24V) 100 300 100
200 (24V)
(24V) 100 200
400 200 300600 400
500 300 400 500 600
700 500 600 700
700
(12V) 200 400 (12V)
600 200
(12V) 200 400
800 400 600
1000 600 800
1200 800 1000 1200
1400 1000 1200 1400
1400
Command Current, mA
Command Current,
Command Current, mA mA
** Flow
Flow
* Flow interims of % for each interims
sizeof
interims
poppet of %
% for each poppet
for each poppet size
size
Description Operation
The ESV1-8-O is a 2-way, 2- In the de-energized posi- In the energized position, The valve flow is propor-
position, pilot operated, tion, this valve allows free flow is blocked from port 2 tional to the current applied
poppet type, normally flow from port 2 to port 1 to port 1, and free flow is to the coil.
open, proportional flow, and restricts flow from port allowed from port 1 to port
control, screw-in cartridge 1 to port 2. 2.
valve.
30 12
10
25
Flow - USgpm
Flow - L/min
8
Flow - L/min
Flow - USgpm
20
15 6
10
4
2
5
2
0 500 1000 1500 2000 2500 3000
Pressure Drop - PSID 0
1 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
Current - Amps
ESV1 8 – * – O – * – ** – *** – * – * – * – ** – *
1 2 3 4 5 6 7 8 9 10 11 12
1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER 10 Coil Series
trol
Aluminum Blank - No Coil
2 Size 0 Cartridge Only S - S Series, 20 W
8 - 8 Size 2G 1/8" BSPP 02-160727 11 Coil Special Features
3G 3/8” BSPP 02-160728 Blank - No coil
3 Seal Material 4T SAE 4 02-160730 00 - No Special Feature
Blank - Buna N
V - Viton 6T SAE 6 02-160731
12 Valve Special Features
8T SAE 8 02-160732
4 Style See section J for housing details. Blank - None
O - Normally open
7 Coil Voltage 9 Connection Type
00 - No coil Blank - No Coil
5 Housing Material 012 - 12 VDC G - ISO 4400 DIN 43650
Blank - Cartridge only 024 - 24 VDC N - Deutsch (DC Only)
A - Aluminum P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.
19,0 HEX
(0.75) 26,2
(1.03)
64,3
(2.53)
Ø 31,8
(1.25)
22,2 HEX
(0.87)
27,8
(1.09) 2 0,750” - 16 THD
Ø 12,62
(.497)
Description Operation
The ESV1-8-C is a 2-way, 2- In the de-energized posi- In the energized position, The valve flow is propor-
position, pilot operated, tion, this valve blocks flow flow from port 1to port 2 is tional to the current applied
poppet type, normally from port 2 to port 1and restricted while free flow is to the coil.
closed, proportional flow free flow is allowed from allowed from port 2 to port
control, screw-in cartridge port 1 to port 2. 1.
valve.
Pressure Drop At Max Poppet Opening Flow vs. Current at 500 PSID
Pressure Drop - bar 12
30
10
25
Flow - USgpm
Flow - L/min
8
Flow - L/min
Flow - USgpm
2 20
6
15
4
1 10
5 2
ESV1 8 – * – C – * – ** – ** – * – * – * – ** – **
1 2 3 4 5 6 7 8 9 10 11 12
1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER 10 Coil Series
trol
Aluminum Blank - No Coil
2 Size 0 Cartridge Only S - S Series, 20 W
8 - 8 Size 2G 1/4" BSPP 02-160727
11 Coil Special Features
3G 3/8” BSPP 02-160728
3 Seal Material Blank - No coil
4T SAE 4 02-160730 00 - No Special Feature
Blank - Buna N
V - Viton 6T SAE 6 02-160731
8T SAE 8 02-160732 12 Valve Special Features
4 Style See section J for housing details. Blank - None
C - Normally closed
7 Coil Voltage 9Connection Type
5
00 - No coil Blank - No Coil
Housing Material 012 - 12 VDC G - ISO 4400 DIN 43650
Blank - Cartridge only 024 - 24 VDC N - Deutsch (DC Only)
A - Aluminum
P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.
19,1 HEX
(.75)
26,2
(1.03)
52,5
(2.07)
Ø 31,8
(1.25)
22,1 HEX
(.875)
27,8
(1.09) 0,750” - 16 THD.
2
Ø 12,62
(.497)
Description Operation
The ESV1-10-O is a 2-way, In the de-energized posi- In the energized position, The valve flow is propor-
2-position, pilot operated, tion, this valve allows free flow is blocked from port 2 tional to the current applied
poppet type, normally flow from port 2 to port 1 to port 1, and free flow is to the coil.
open, proportional flow, and restricts flow from port allowed from port 1 to port
control, screw-in cartridge 1 to port 2. 2.
valve.
45 24
40 20
2
35
Flow - USgpm
Flow - L/min
16
Flow - L/min
Flow - USgpm
30
1
25 12
20
8
15
10 4
5 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
0 500 1000 1500 2000 2500 3000 Current - Amps
Pressure Drop - PSID
ESV1 10 – * – O – * – ** – *** – * – * – * – ** – **
1 2 3 4 5 6 7 8 9 10 11 12
1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER
trol 10 Coil Series
Aluminum Blank - No Coil
2 Size 0 Cartridge Only J - J Series, 20 W
10 - 10 Size 3B 3/8" BSPP 02-175462
11 Coil Special Features
6T SAE 6 566151
3 Seal Material 2G 1/4" BSPP 876702 Blank - No coil
Blank - Buna N 00 - No Special Feature
V - Viton 3G 3/8" BSPP 876703
6H SAE 6 876700 12 Valve Special Features
8H SAE 8 876701 Blank - None
4 Style
See section J for housing details.
C - Normally Open
7 Coil Voltage 9 Connection Type
5 Housing Material 00 - No coil Blank - No Coil
Blank - Cartridge only 012 - 12 VDC G - ISO 4400 DIN 43650
A - Aluminum 024 - 24 VDC N - Deutsch (DC Only)
P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.
19,1 HEX
(.75) 34,6
(1.36)
70,3
(2.77)
Ø 38,9
(1.53)
25,4 HEX
(1.00)
31,7
(1.25) 0,875” - 14 THD.
2
Ø 15,80
(.622)
Description Operation
The ESV1-12-O is a 2-way, In the de-energized posi- In the energized position, The valve flow is propor-
2-position, pilot operated, tion, this valve allows free flow is blocked from port 2 tional to the current applied
poppet type, normally flow from port 2 to port 1 to port 1, and free flow is to the coil.
open, proportional flow, and restricts flow from port allowed from port 1 to port
control, screw-in cartridge 1 to port 2. 2.
valve.
65 30
60
55 25
2
Flow - USgpm
Flow - L/min
50
Flow - L/min
Flow - USgpm
45 20
40
1 35 15
30
25 10
20
15 5
10
5 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
0 500 1000 1500 2000 2500 3000 Current - Amps
Pressure Drop - PSID
ESV1 12 – * – O – * – ** – ** – * – * – * – ** – **
1 2 3 4 5 6 7 8 9 10 11 12
1 6 Port Size
Function
ESV1 - Proportional flow con- CODE PORT SIZE HOUSING NUMBER
trol 10 Coil Series
Aluminum Blank - No Coil
2 Size 0 Cartridge Only J - J Series, 20 W
12 - 12 Size 4G 1/2" BSPP 02-161118
11 Coil Special Features
4GU 1/2" BSPP 02-161116
3 Seal Material Blank - No coil
6G 3/4" BSPP 02-161117
Blank - Buna N 00 - No Special Feature
V - Viton 6GU 3/4" BSPP 02-161115
10T SAE 10 02-160640 12 Valve Special Features
10TU SAE 10 02-160641 Blank - None
4 Style
12T SAE 12 02-160644
0 - Normally Open
12TU SAE 12 02-160645
See section J for housing details.
5 Housing Material 7 Coil Voltage 9 Connection Type
Blank - Cartridge only
A - Aluminum 00 - No coil Blank - No Coil
012 - 12 VDC G - ISO 4400 DIN 43650
024 - 24 VDC N - Deutsch (DC Only)
P - Conduit
8 Type of Power Q - Spade terminals
Blank - No coil W - Leadwire
D - 1DC w/o diode Y - Amp JR (DC Only)
B - DC with diode For coil dimensions see Section C.
19,1 HEX
(.75)
34,6
(1.36)
72,2
(2.87)
Ø 38,9
(1.53)
31,8 HEX
(1.25)
1.062” - 12 THD.
44,7 2
(1.76)
Ø 23,75
(.935)
Description Operation
The EFV1-10-O is a normally The valve is controlled by The maximum intended different from those
open, unidirectional, current supplied to the coil. pressure drop is 300 PSID. obtained with flow from
uncompensated, spool At zero current, the valve is At pressure drops above port 2 to port 3.
type, two way, proportional fully open from port 2 to 300 PSID, almost no Since the spool and arma-
flow control, screw-in car- port 3. At 1500 to 1600 mA increase in flow is obtained. ture are pressure balanced,
tridge valve. (12V coil) the valve is fully The intended flow direction
closed. Port 1 is used for is from port 2 to port 3. the operating pressure
pressure balancing the Operation of the valve with does not affect the operat-
spool and armature and flow from port 3 to port 2 ing characteristics of the
must be blocked in all will produce flow vs current valve. The operating point
cases. and flow vs pressure drop of the valve is determined
curves that are significantly only by current, pressure
drop and temperature.
1 2
1
Note
Port 1 is unused and must
be plugged.
Fl o w - U S g p m
Fl o w - U S g p m
Fl o w - L/m i n
40 Fl o w - L/m i n 40
10 10
8 30 8 30
6 6
20 20
4 4
2 10 2 10
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pressure Drop - PSID Pressure Drop - PSID
Fl o w - L/m i n
40
Fl o w %
10
50
8 30
6
20 25
4
2 10
0
0 0 0 200 400 600 800 1000 1200 1400 1600
0 50 100 150 200 250 300
Current - mA
Pressure Drop - PSID
Note
To determine operating
characteristics for the flow
rating selected, at a specific
differential pressure, first
determine maximum flow
from upper curve at the dif-
ferential pressure value.
This will be the “100%
flow” flow on the lower
curve.
Parameters: 400 Hz PWM
1 2 3 4 5 6 7 8 9 10
2
0 000 No manifold block –
Size
6 Bleed Screw and A 03B Aluminum, Light Duty 02-173358
10 - 10 Size 3/8” BSPP
Manual Override 06T Aluminum, Light Duty 566162
0 - No core tube special SAE 6
3 Seals features 02G Aluminum, 1/4” BSPP 876705
N - Buna-N S - Screw-in type manual 03G Aluminum, 3/8” BSPP 876714
®
override 06H Aluminum, SAE 6 876704
V - Viton 08H Aluminum, SAE 8 876711
S 02G Steel, 1/4” BSPP 02-175127
4 Logic 03G Steel, 3/8” BSPP 02-175128
06T Steel, SAE 6 02-175124
0 - Normally Open 08T Steel, SAE 8 02-175125
Note: Both the manifold and port plug are required.
9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve. has special features, omitted
if ”00.“)
Dimensions 44,2 (1.74)
mm (inch)
32,8 (1.29)
Torque cartridge in housing 32,0
(1.26) 19,1 (0.75)
S - 68-75 Nm
(50-55 ft. lbs)
A - 47-54 Nm
(35-40 ft. lbs)
108,7
(4.28)
86,4
(3.40)
64,0
(2.52)
47,2 3
(1.86)
2
1
Note: EFV1-10 with DIN-43650 connector Note: Port 1 is unused and must be plugged. Note - S type manual override shown
shown.
B
Description Operation
The EFV1-10-C is a normal- The valve is controlled by The maximum intended different from those
ly closed, unidirectional, current supplied to the coil. pressure drop is 300 PSID. obtained with flow from
uncompensated, spool At zero current, the valve is At pressure drops above port 3 to port 2.
type, two way, proportional fully closed from port 3 to 300 PSID, almost no Since the spool and arma-
flow control, screw-in car- port 2. At 1500 mA (12V increase in flow is obtained. ture are pressure balanced,
tridge valve. coil) the valve is considered The intended flow direction the operating pressure
fully open. This is the maxi- is from port 3 to port 2. does not affect the operat-
mum intended current level Operation of the valve with ing characteristics of the
for use in applications. Port flow from port 2 to port 3 valve. The operating point
1 is used for pressure bal- will produce flow vs current of the valve is determined
ancing the spool and arma- and flow vs pressure drop only by current, pressure
ture and must be blocked in curves that are significantly drop and temperature.
all cases.
1 2
1
Note
Port 1 is unused and must
be plugged.
Fl o w - U S g p m
Fl o w - U S g p m
Fl o w - L/m i n
Fl o w - L/m i n
10 40 10 40
8 30 8 30
6 6
20 20
4 4
10 10
2 2
0 0 0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pressure Drop - PSID Pressure Drop - PSID
Fl o w - L/m i n
40
Fl o w %
10
50
8 30
6
20 25
4
10
2
0
0 0 0 200 400 600 800 1000 1200 1400 1600
0 50 100 150 200 250 300
Current - mA
Pressure Drop - PSID
Note
To determine operating
characteristics for the flow
rating selected, at a specific
differential pressure, first
determine maximum flow
from upper curve at the dif-
ferential pressure value.
This will be the “100%”
flow on the lower curve.
Parameters: 400 Hz PWM
1 2 3 4 5 6 7 8 9 10
2
0 000 No manifold block –
Size
6 Bleed Screw and A 03B Aluminum, Light Duty 02-173358
10 - 10 Size 3/8” BSPP
Manual Override 06T Aluminum, Light Duty 566162
0 - No core tube special SAE 6
3 Seals features 02G Aluminum, 1/4” BSPP 876705
N - Buna-N S - Screw-in type manual 03G Aluminum, 3/8” BSPP 876714
®
override 06H Aluminum, SAE 6 876704
V - Viton 08H Aluminum, SAE 8 876711
S 02G Steel, 1/4” BSPP 02-175127
4 Logic 03G Steel, 3/8” BSPP 02-175128
06T Steel, SAE 6 02-175124
C - Normally Closed 08T Steel, SAE 8 02-175125
Note: Both the manifold and port plug are required.
9 Coil Model Code* 10 Special Features
E-Series Coils See Section C. 00 - None
* These model digits will not be stamped (Only required when valve
on the valve. has special features, omitted
if ”00.“)
44,2 (1.74)
Dimensions
mm (inch) 32,8 (1.29)
32,0
Torque cartridge in housing (1.26) 19,1 (0.75)
S - 68-75 Nm
(50-55 ft. lbs)
A - 47-54 Nm
(35-40 ft. lbs) 108,7
(4.28)
86,4
(3.40)
64,0
(2.52)
47,2 3
(1.86)
2
Note: EFV1-10 with DIN-43650 connector Note: Port 1 is unused and must be plugged. Note - S type manual override shown
shown.
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B-33
EFV1-12-O
Proportional flow control
valve, normally open,
spool type
Description Operation
The EFV1-12-O is a The valve is controlled by At pressure drops above Since the spool and arma-
normally open, unidirection- current supplied to the coil. 300 PSID, almost no ture are pressure balanced,
al, uncompensated, spool At zero current, the valve increase in flow is obtained. the operating pressure
type, two way, proportional is fully open from port 2 to The intended flow direction does not affect the operat-
flow control, screw-in port 3. At 1500 to 1600 mA is from port 2 to port 3. ing characteristics of the
cartridge valve. (12V coil) the valve is fully Operation of the valve with valve. The operating point
closed. Port 1 is used for flow from port 3 to port 2 of the valve is determined
pressure balancing the spool will produce flow vs current only by current, pressure
and armature and must be and flow vs pressure drop drop and temperature.
blocked in all cases. curves that are significantly
The maximum intended different from those
pressure drop is 300 PSID. obtained with flow from
port 2 to port 3.
2 2
1 1
Note
Port 1 is unused and must
be plugged.
20 100 100
Flow - L/min
- L/min
2525 2525
60 60
8080 8080
Flow - USgpm
Flow - USgpm
USgpm
Flow - USgpm
1520
20 2020
Flow - L/min
Flow - L/min
L/min
Flow - L/min
Flow -Flow
Flow -Flow
40 10 40
6060 6060
1515 1515
20 510
10 20
4040 1010 4040
0 0
5 5 0
2020 5 5 2020
300 0 50 100 150 200 250 300
0 0 Pressure Drop - PSID 0 0 0 0 0 0
0 0 5050 100100 150150 200 200 250250 300
300 0 0 5050 100100 150150 200 200 250
250 300
300
Pressure
Pressure Drop
Drop - PSID
- PSID Pressure
Pressure Drop
Drop - PSID
- PSID
Flow vs Current
100
100 Note
3030 To100
100 determine operating
80 75 100
100
Flow - L/min
60 8080 rating
7575 selected, at a specific
Flow - USgpm
Flow - USgpm
20
Flow %
Flow %
1 2 3 4 5 6 7 8 9 10
64,0
(2.52)
Note
EFV1-12 with DIN-43650
connector shown.
68,6
3 (2.70) 3
Note 2 2
Port 1 is unused and must
be plugged.
1 1
Description Operation
The EFV1-12-C is a nor- The valve is controlled by The maximum intended obtained with flow from
mally closed, unidirection- current supplied to the coil. pressure drop is 300 PSID. port 3 to port 2.
al, uncompensated, spool At zero current, the valve is At pressure drops above Since the spool and arma-
type, two way, proportion- fully closed from port 3 to 300 PSID, almost no ture are pressure balanced,
al flow control, screw-in port 2. At 1500 mA (12V increase in flow is obtained. the operating pressure does
cartridge valve. coil) the valve is considered The intended flow direction not affect the operating
fully open. This is the maxi- is from port 3 to port 2. characteristics of the valve.
mum intended current level Operation of the valve with The operating point of the
for use in applications. flow from port 2 to port 3 valve is determined only by
Port 1 is used for pressure will produce flow vs current current, pressure drop and
balancing the spool and and flow vs pressure drop temperature.
armature and must be curves that are significantly
blocked in all cases. different from those
2 2
1 1
Note
Port 1 is unused and must
be plugged.
7070
Flow - L/min
- L/min
60
4040
15
- USgpm
Flow - USgpm
Flow - USgpm
Flow - USgpm
1010
- L/min
Flow - L/min
Flow - L/min
Flow - L/min
30 50 6060
1515
10 30
4030 5050
20 Flow
Flow
30
Flow
1010 4040
2020
Flow
10 55 5 20 3030
1010 55 2020
10
0 0 0 1010
200 000 50 100 150 2000 0 00 00
00 5050
Pressure100
100 - PSID150
Drop 150 200
200 00 5050 100
100 150
150 200
200
Pressure
PressureDrop
Drop- PSID
- PSID Pressure
PressureDrop
Drop- PSID
- PSID
Flow vs Current
(Flow rating ”B“)
100
50 1515 Note
100
100
5050 To determine operating
40 75
characteristics for the flow
Flow - L/min
4040 7575
USgpm
Flow - USgpm
Flow - L/min
Flow - L/min
30 1010
differential pressure, first
Flow %
50
Flow %
Flow -Flow
3030 determine
5050 maximum flow
20
from upper curve at the dif-
25
55 2020 ferential pressure value.
10 2525
This will be the “100%”
1010
0 0 flow on the lower curve.
400 000 200 400 600 800 1000 1200 1400 0 0 00
0 0 200
200 400 600
600 800
400 Current - mA1000
800 10001200
12001400
1400 00 200
200 400
400 600
600 800
800 1000
10001200
12001400
1400
Current
Current- mA
- mA Current
Current- mA
- mA
Parameters:
400 Hz PWM
1 2 3 4 5 6 7 8 9 10
64,0
(2.52)
68,6
3 (2.70) 3
Note
2 2
Port 1 is unused and must
be plugged.
1 1
Description Operation
The EFV2-12-O is a normal- port 2. If port 2 is blocked Current supplied to the coil downstream system pres-
ly open, three port, pres- the valve functions as a controls the valve. At zero sure. As current is increased
sure compensated, propor- restrictive, 2 way, pressure current, the valve is fully to the solenoid the flow out
tional flow control valve. compensated flow regulator. open from port 1 to port 3. of port 3 will decrease.
The valve can be used as a At 1600 mA (12V coil) the
priority flow regulator, with valve is fully closed. The
regulated flow being sup- valve will regulate flow out
plied to port 3 and excess of port 3 regardless of
flow being by-passed to
Sectional View Hysteresis 19,1 (0.75) 1.5 USgpm max with 400Hz PWM driver
Leakage (fully closed) 240 cm3/min (15 in3/min)1.26 at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
86,3valve
Current to fully open 350 ± 100mA (12V coil), 175 ± 50 mA (24V coil)
(3.40)
Current to fully close valve 1600 ± 200 mA (12V coil), 800 ± 100 mA (24V coil)
Recommended PWM frequency 64,0 200 - 400 Hz
(2.52)
Coil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/116/13
Cavity C-12-3
Regulated Seal kit 68,6 9900171-000 (Buna-N)
Flow 3 (2.70) 3 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont
Excess 2 2
Flow
1 1
Inlet
B
Pressure Drop Port 1 to Port 2 Pressure Drop Port 1 to Port 3
400 180
180
400
Pressure Drop (PSI)
A
Flow (GPM)
Flow (GPM)
10 10 10 10 By-Pass
By-Pass
Mode
Mode
8 8 8 8
2 Port
2 Port
Mode
Mode B
6 6 6 6
2 Port
2 Port
Mode C
Mode
4 4 4 4
D
2 2 2 2
E F
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000
Current
Current
(Milli-amps)
(Milli-amps) A 0 amps B 0.3 amps C 0.6 amps PSI
Current
E 1.2 amps Current
F (Milli-amps)
(Milli-amps)
D 0.9 amps 1.5 amps
Parameters:
400 Hz PWM
GPM GPM
15.0 15.0
A
12.5 12.5
A
10.0 10.0
B B
7.5 7.5
C C
5.0 5.0
D D
2.5 2.5
E F E
0.0 0.0 F
0 500 1000 1500 2000 2500 3000 3500 4000 0 500 1000 1500 2000 2500 3000 3500 4000
A 0 amps B 0.3 amps C 0.6 amps PSI A 0 amps B 0.3 amps C 0.6 amps PSI
D 0.9 amps E 1.2 amps F 1.5 amps D 0.9 amps E 1.2 amps F 1.5 amps
Note: Pressure Compensation curves are shown for “B” spool valves.
1 2 3 4 5 6 7 8 9 10
64,0
(2.52)
Note
EFV2-12 with DIN-43650
connector shown.
68,6
3 (2.70) 3
2 2
1 1
Description Operation
The EFV2-12-C is a nor- If port 2 is blocked the Current supplied to the coil The valve will regulate flow
mally closed, three port, valve functions as a restric- controls the valve. At zero out of port 3 regardless of
pressure compensated, tive, 2 way, pressure com- current, the valve is fully downstream system pres-
proportional flow control pensated flow regulator. closed from port 1 to port 3. sure. As current is
valve. The valve can be At 1500 to 1600 mA (12V increased to the solenoid
used as a priority flow coil) the valve is fully open. the flow out of port 3 will
regulator, with regulated increase.
flow being supplied to
port 3 and excess flow
being by-passed to port 2.
EFV2-12-C
Functional Symbol EFV2-12-0
RATINGS AND SPECIFICATIONS
Profile View Hysteresis 19,1 (0.75) 1.5 USgpm max with 400Hz PWM driver
Leakage (fully closed) 240 cm3/min (15 in1.263
/min) at 3000 PSID
Ambient operating temperature -30° to 90°C (-22° to 194°F)
Maximum oil temperature 120°C (248°F)
Maximum internal coil temperature 200°C (392°F)
Nominal supply voltage 12/24 V
Current to fully 86,3
open valve 1600 ± 200 mA (12V coil), 800 ± 100 mA (24V coil)
(3.40)
Current to fully close valve 350 ± 100 mA (12V coil), 175 ± 50 mA (24V coil)
Recommended dither frequency64,0 200 - 400 Hz
(2.52)
Coil resistance at 20°C (68°F) 4.7 Ω (12V), 19.0 Ω (24V)
Mass Cartridge only 0,37 kg (0.82 lb)
Cartridge with coil and end nut 0,73 kg (1.62 lb)
Fluid All general purpose hydraulic oils such as:
MIL-H-5606, SAE 10, SAE 20, DTE 24, etc.
Filtration Cleanliness code 18/116/13
Cavity C-12-3
Seal kit 68,6 9900171-000 (Buna-N)
3 (2.70) 3 9900172-000 (Viton®)
Viton is a registered trademark of E.I. DuPont
2 2
1 1
400 180
350
300 150
250
B
200 100
150
A
100 50
50
0
0
0 5 10 15 20 25 30 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Flow-US gpm Flow-US gpm
A - A spool pressure drop
B - B spool pressure drop
Flow vs Current
18 A - A spool
16 B - B spool
14 2 Port
By-Pass Mode Mode
12
Flow (GPM)
10 By-Pass
Mode
8
6
A 2 Port Mode
4
B
2
0
0 200 400 600 800 1000 1200 1400 1600 1700
Current (mA)
20.0 20.0
17.5 G 17.5 G
15.0 15.0
Flow-US gpm
F F
Flow-US gpm
12.5 E 12.5 E
10.0 D 10.0
D
7.5 7.5
C C
5.0 5.0
2.5 B 2.5 B
0.0 A 0.0 A
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500 3000 3500
Pressure - psi Pressure - psi
A - 0.3 AMPS B - 0.6 AMPS C - 0.9 AMPS A - 0.3 AMPS B - 0.6 AMPS C - 0.9 AMPS
D - 1.2 AMPS E - 1.5 AMPS F - 1.8 AMPS D - 1.2 AMPS E - 1.5 AMPS F - 1.8 AMPS
G - 2.0 AMPS G - 2.0 AMPS
Note: Pressure Compensation curves are shown for “B” spool valves.
1 2 3 4 5 6 7 8 9 10
86,3
(3.40)
64,0
(2.52)
Note: EFV2-12 with DIN-43650 connector shown.
68,6
3 (2.70) 3
2 2
1 1
ToughCoils™
C
™
Vickers ToughCoils have integrated connectors are leads. and industrial applications.
been designed to provide rated up to IP69K environ- The best in class, one-
industry leading environ- mental protection. piece, shell encapsulated, The exclusive compact coil
mental protection and sole- ToughCoils™ are available design meets the most design from Vickers, offers
noid performance in a with a variety of popular stringent environmental the advantage of field retro-
compact and rugged pack- integrated connection requirements for mobile fit-ability on all existing, and
age. ToughCoils™ with options and with wire new, applications.
Toughcoils™ Features
• IP69K Environmental • “Thermal Shock Dunk” • Field Retrofit-able • Steel Shell Encapsulated
Protection - This rating Test - Vickers ToughCoils ToughCoils™ replace all Design ToughCoils™ pro-
provides protection have been qualified to current Vickers coils used vide protection against
against the ingress of withstand the toughest on D Frame and Shell physical and environmen-
dust and high pressure Mobile Equipment type coils. Compact coil tal damage.
jet stream. The IP69K “Thermal Shock Dunk” dimensions allow substi-
test was designed tests. Integrated tution in all existing appli-
specifically for rating pro- Deutsch, MetriPack1 and cations. ToughCoils are
tection against a high- Leadwire2 connectors available for most 8, 10,
pressure jet stream, high exceed “Thermal Shock 12, 16 and 20 series
liquid temperature and Dunk” test qualifications valves. No additional
close nozzle distance at 140°C. The “Thermal water/weather proofing
from the enclosure sur- Shock Dunk” test is required.
face. IP69K protection is requires coils to be heat-
standard on coils with ed, reaching a stabilized
MetriPac or Deutsch, temperature of 100°C,
integrated connectors. then immediately
immersed in a solution at
0°C. The thermal shock
is repeated five times
with the coil monitored
for dielectric strength in
the solution and function-
al performance is verified.
In addition, ToughCoils™
passed a more severe
powered dunk test con-
Vickers ToughCoils™, ducted from 100°C to
with rated connector, 0°C with 115% rated
meet or exceed all major voltage applied.
OEM environmental pro-
1
MetriPack® 150 and MetriPack® 280
are registered trade marks of Delphi
tection requirements Packard Electric Systems
2
Coils with integrated connectors are
recommended for applications in harsh
environments.
MCSC – * – *** – * – ** – * – ** – 10
1 2 3 4 5 6 7 8
E0 - Weather–Pack (Packard)
Connector (Standard length
W0 - Leadwire
[350 Bar] female on wire leads 7
F0 - Weather–Pack (Packard)
00 - No Special Features
024 - 24 Volt
DT04-2P, Integrated 8
036 - 36 Volt
(DC Only) Mating male on wire leads
10 - Design Code
048 - 48 Volt
Connector: Deutsch Mating Connector:
Specifications
RATINGS AND SPECIFICATIONS
Duty Rating Continuous from 85% to 110% of nominal voltage
Operating temperature 100°C (212°F) continuous @ nominal voltage
Lead Wires 18 gauge, standard 610 mm (24”) long, UL style 3173 CSA CL 1251
(meets SAE J1128 XLPE style SXL)
Power Rating S Series: 20W
P Series: 23W
J Series: 23W
H Series: 29W
Encapsulent Glass filled nylon
Magnet Wire U.L. class N, 200°C (392°F) NEMA pub. No. MW 1000, section MW 35–C (single)
Flyback diode (arc suppressor) Maximum recurrent peak reverse voltage – 800 V (optional)
Environmental Protection
CONNECTOR IP65 IP67 IP69K THERMAL SHOCK DUNK
G0: DIN 43650 X*
Q0: Spade
Y0: Amp Jr. X X1*
W0: Wire Leads X X X1
N0: Deutsch X X X X
D0: Metri-Pack 150 X X X X
J0: Metri-Pack 280 X X X X
1 Passed environmental testing, but not as robust as other connectors
* Rating dependent on mating connector
CAUTION
∑ Coils may be hot to
touch if used in
continuous duty applications.
STD.
VOLTAGES AMPERES*
12 DC 1.67 Voltage Type B
24 DC 0.83 (+) (-)
36 DC 0.56
24 AC 0.93
115 AC 0.19
230 AC 0.10
*Nominal voltage 25°C (77°F).
STD.
VOLTAGES AMPERES*
Voltage Type B
12 DC 1.92
(+) (-)
24 DC 0.96
36 DC 0.64
24 AC 1.06
115 AC 0.22
230 AC 0.11
*Nominal voltage 25°C (77°F).
STD.
VOLTAGES AMPERES*
12 DC 1.92 Voltage Type B
24 DC 0.96 (+) (-)
36 DC 0.64
24 AC 1.06
115 AC 0.22
230 AC 0.11
*Nominal voltage 25°C (77°F).
STD.
VOLTAGES AMPERES*
Voltage Type B
12 DC 2.42
24 DC 1.21 (+) (-)
36 DC 0.81
24 AC 1.34
115 AC 0.28
230 AC 0.14
*Nominal voltage 25°C (77°F).
28,0 [1.10]
Q0 W0
Spade Connector Leadwire
N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior Timer integrated connector
29,7 33,9
[1.17] 24,1 [.95] [1.33] 25,4 [1.00]
D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector
33,5 [1.32]
(.685) 29,5 [1.16]
31,5 [1.24]
29,7 [1.17]
31,5 [1.24]
Q0 W0
Spade Connector Leadwire
35,3 [1.39]
36,8 1.45] 5,1 [.20]
N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior Timer integrated connector
33,3 37,3
[1.31] 27,7 [1.09] [1.47] 28,9 [1.14]
D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector
33,5 [1.32] C
(.685) 29,5 [1.16]
31,5 [1.24]
29,7 [1.17]
31,5 [1.24]
Q0 W0
Spade Connector Leadwire
35,3 [1.39]
36,8 1.45] 5,1 [.20]
N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior Timer integrated connector
33,3 37,3
[1.31] 27,7 [1.09] [1.47] 28,9 [1.14]
D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector
SPECIFICATIONS
Hydraulic Performance Specifications for explosion proof valves are the same as the base valve.
For details please refer to the base valve page reference.
Coil Temperature Range -40° to 100°C (-40° to 212°F) C
Coil Duty Continuous from 85% to 110% of nominal voltage
Housing Type Explosion proof version with 1/2" threaded conduit hub
Coil Type Epoxy encapulated lead wire coil
Lead Wire 24" Long, 18 gauge with 1/32" cross linked Polyethylene insulation
APPROVALS
UL File AU2206, Component - Industrial truck accessory, Battery powered
CSA Both for general purpose and Hazardous locations
Class I, Group C & D
Class II, Group E, F & G
SUMMARY
Typical
Application Base
Pressure Rated flow Valve Section
Model Code Description psi (bar) l/min (Usgpm) design Reference
SV1E-10-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 45 (12) SV1-10-C A
SV2E-10-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 23 (6) SV2-10-C A
SV3E-10-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 45 (12) SV3-10-C A
SV4E-10-C-XX-XXXXU 2 way, 2 position, normally closed, spool type 210 (3000) 23 (6) SV4-10-C A
SV1E-16-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 132 (35) SV1-16-C A
SV2E-20-C-XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 227 (60) SV2-20-C A
SV4E-10-0-XX-XXXXU 2 way, 2 position, normally open, spool type 210 (3000) 23 (6) SV4-10-0 A
SV3E-10-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 45 (12) SV3-10-0 A
SV5E-10-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 45 (12) SV5-10-0 A
SV3E-16-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 132 (35) SV3-16-0 A
SV3E-20-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 227 (60) SV3-20-0 A
SV1E-10-3-XX-XXXXU 3 way, 2 position, spool type 210 (3000) 23 (6) SV1-10-3 A
SV1E-10-4-XX-XXXXU 4 way, 2 position 210 (3000) 23 (6) SV1-10-4 A
SV2E-10-4-XX-XXXXU 4 way, 2 position, circuit center 210 (3000) 23 (6) SV2-10-4 A
SV3E-10-4-XX-XXXXU 4 way, 2 position, normally open 210 (3000) 23 (6) SV3-10-4 A
SV4E-10-4-XX-XXXXU 4 way, 2 position, tandem center 210 (3000) 23 (6) SV4-10-4 A
REPLACEMENT COIL PART NUMBERS
Voltage Assembly Number Amperes (A) Power (W) Lead Color
12 VDC 888831 1.50 20 Red
24 VDC 888832 0.75 20 Black
36 VDC 888834 0.50 20 Blue
48 VDC 888835 0.38 20 Purple
110 VDC 888836 0.16 20 Brown
24 VAC 888837 0.75 20 Orange
115 VAC 888838 0.16 20 Yellow
230 VAC 888840 0.08 20 Red/White
480 VAC 888841 0.04 20 Black/White
1 2 3 4
53,9 31,8
(2.125) (1.250)
Dimensions
mm (inch)
Coil Configurations “F”- Weather-Pack ”Q“ - Spade terminal ”U“– DIN 43650
male on leads
CAUTION
∑ Coils may be
hot to touch
if used in continuous
duty applications.
SPECIFICATIONS CAUTION
Standard Voltage Resistance Power Coils may be
∑
12 VDC 4.7 Ω 30 W hot to touch if
24 VDC 19.0 Ω 30 W used in continuous
duty applications.
1 2 3 4 5 6
Model code positions 2, 3, 4, 5 and 6 are integrated into EFV model code when ordered with valve.
Coil Kits “W” - 610 “C” - Deutsch “E” - Weather- “H” - Metri-
mm (24 inch) DT0402P on Pack female Pack 150 male
“G” - DIN 43650 lead wire leads on leads on leads
54,1 50,3
STANDARD COIL PART
(2.13) (1.98)
NUMBERS
Model Code Assembly
Number 56,134
(2.21)
SC-012BGE00 4995052-230
SC-012BWE00 4995052-231
SC-012DGE00 4995052-001
SC-012DWE00 4995052-002
Ø 44,2
SC-024BGE00 4995052-232 (1.74)
SC-024BWE00 4995052-233 Note: Width all
Ø 20,7 configurations
SC-024DGE00 4995052-003 (0.815)
SC-024DWE00 4995052-004
Note
This product has been designed and tested to meet spe-
cific standards outlined in the European Electro-magnetic
Compatibility Directive (EMC) 89/336/EEC, amended by
91/26/EEC, 92/31/EEC and 93/68/EEC, article 5. For
instructions on installation requirements to achieve
effective protection levels, see this leaflet and the
Installation Wiring Practices for Vickers Electronic Products
leaflet 2468. Wiring practices relevant to this Directive are
indicated by a warning symbol and Electromagnetic
Compatibility (EMC).
Mechanical
Housing PA6 glass-reinforced plastic (conforming to UL-94HB). Color: gray
Mounting interface ISO 4400 (DIN 43650)
Cable clamp Pg9 screw type
Cable diameter Ø 5 to 10 mm (0.197 to 0.394” dia.)
Wire section 0,5 to 1,0 mm2 (20-17 AWG)
Temperature, ambient range -20° to +70°C (-4° to +158°F)
Mass 0,07 kg (0.154 lb)
Input/Output
Characteristics C
USX USX
Gain setting Gain setting
Deadband Deadband
compensation compensation
Time Time
Installation Dimensions
mm (inch)
39 Solenoid Connections
(1.54)
No connection
1 (or 2)
34
(1.34)
2
2 (or 1)
38
(1.5)
1
4 3 2 1
4 3 2 1
24V 24V
0V 0V
P
0V 0V
+10V
4 3 2 1
4 3 2 1
4-20 mA Command Signal Connections when replacing –10 design power plug
EHH-AMP-702-K-20 with –20 design and only 3 wires exist
EHH-AMP-702-D/J/K-20
4 3 2 1
24V
0V
4 3 2 1
24V
4-20 mA 0V
0V 0V
WARNING
Electromagnetic Compatibility (EMC) - Screened cables should be used and particular
• attention paid to the grounding of the screens as shown in the above diagrams.
Assembly Showing
Wiring Connection C
Points
WARNING
Ensure cable
• clamp nut is ade-
* quately tightened to secure
cable. Do not connect, or
disconnect, the plug while
power is on. Do not mount,
or dismount, the plug while
power is on.
Wiring Preparation
4 x 0.5-1.0 mm 2
(20 AWG-17 AWG)
5 (0.2)
Ø 5-10 (0.197-0.394 dia)
40 (1.6)
*All seals must be fitted correctly at plug installation to provide protection to IP67 (IEC 529).
Note
This product has been designed and tested to meet spe-
cific standards outlined in the European Electro-magnetic
Compatibility Directive (EMC) 89/336/EEC, amended by
91/26/EEC, 92/31/EEC and 93/68/EEC, article 5. For
instructions on installation requirements to achieve effec-
tive protection levels, see this leaflet and the Installation
Wiring Practices for Vickers Electronic Products leaflet
2468. Wiring practices relevant to this Directive are indicat-
ed by a warning symbol and Electromagnetic Compatibility
(EMC).
OPERATING DATA
Electrical
Connections
1 24V DC
2 OV (power and signal)
3 Positive command signal
4 Negative command signal
Power (input) supply 20-30V DC including ± 10% maximum ripple
ripple (peak-to-peak)
24V DC nominal
Absolute maximum voltage 40V
Max. power consumption 35W
including solenoid
Reverse polarity protected Yes
Short circuit protected Yes
Maximum output current 1,6A
Maximum output voltage typical Typically 1,5V below supply voltage
(1,6A output current)
Command signal
For output (LED on) 15V to 24V
For no output (LED off) 0V to 5V
Input impedance 2700 ohms
Deadband adjustment range <100 - 1000 mA
Gain adjustment range 0.02A to 1,6A (maximum)
Dither adjustment range 0 to 500 mA
Ramp time 50 ms to 5s
PWM frequency 1200 Hz ± 10%
Dither frequency 120 Hz ± 10%
Protection IEC 529: IP67 (when correctly installed with interface seal in place)
Fully short-circuit and reverse-polarity protected
Isolation to VDE 0110 Group “B”
Electromagnetic compatibility (EMC):
Emission EN 50081-2
Immunity EN 50082-2
Mechanical
Housing PA6 glass-reinforced plastic (conforming to UL-94HB). Color: gray
Mounting interface ISO 4400 (DIN 43650)
Cable clamp Pg9 screw type
Cable diameter Ø 5 to 10 mm (0.197 to 0.394” dia.)
Wire section 0,5 to 1,0 mm2 (20-17 AWG)
Temperature, ambient range -20° to +70°C (-4° to +158°F)
Mass 0,07 kg (0.154 lb)
Input/Output Command
Characteristics signal C
Functions
Switch-on/off: after switch-
ing on with a 15V signal the
amplifier will remain in the 24V,
“on” condition with a com- typical
mand signal above 6V. The
command signal must be
reduced to below 5V to Time
achieve switch-off of the
amplifier. Output Ramp time
current
Gain
adjustment
Deadband compensation
Time
Installation Dimensions
mm (inch)
39 Solenoid Connections
(1.54)
No connection
1 (or 2)
34
(1.34)
2
2 (or 1)
38
(1.5)
1
4 3 2 1
P
Installation Wiring
4 3 2 1
24V
0V
>15V
WARNING
Electromagnetic
• Compatibility
(EMC) - Screened cables
should be used and particu-
lar attention paid to the
grounding of the screens as
shown in the above diagram.
Assembly Showing
Wiring Connection C
Points
WARNING
Ensure cable
• clamp nut is ade-
* quately tightened to secure
cable. Do not connect, or
disconnect, the plug while
power is on. Do not mount,
or dismount, the plug while
power is on.
Wiring Preparation
4 x 0.5-1.0 mm 2
(20 AWG-17 AWG)
5 (0.2)
Ø 5-10 (0.197-0.394 dia)
40 (1.6)
*All seals must be fitted correctly at plug installation to provide protection to IP67 (IEC 529).
2 3
1
Description Operation
The MRV3-10 is a 3-way, This valve will direct flow the operator 90°, flow cross-over transition, all
2 or 3 position, manual between ports 1 and 3 will be directed between ports are blocked.
semi-rotary directional and block port 2 in one ports 1 and 2 and port 3
screw-in cartridge valve. position, and by turning will be blocked. During
2 3
3 60
2 3 4
2 40
2
1
2
20
1 Flow - L/min (21,8 cSt oil @ 49°C)
1
0 10 (21,8 cSt oil @ 49°C)20
Flow - L/min
80 0 6 0
00 Flow - L/min (21,8 cSt oil @ 49°C) 20
2 10 4 6
80 0 10 20 6
Pressure Drop - bar
Pressure Drop - psi
60
- bar
40 60 4
Drop
Drop
4
Drop
Drop
40
2
Pressure
Pressure
20 40
Pressure
Pressure
2
D-4 20
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
2
0 20 0
Model Code MRV3-10
1 2 3 4 5 6
D
1
Function 4Manual operators 5 Port size
MRV3 - Manual rotary valve O - No operator O - Cartridge only
D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
2 Size D2 - Lever (2-position Aluminum Aluminum
10 - 10 Size detent)* Light duty Fatigue rated
E - Ball (3-position 3B 3/8” BSPP 02-173358 –
3 Seals detent)* 6T SAE 6 566162 –
Blank - Buna-N E2 - Ball (2-position
2G 1/4” BSPP – 876705
V - Viton® detent)*
K - Knob (2-position, 3G 3/8” BSPP – 876714
no detent) 6H SAE 6 – 876704
*Light duty housing only. 8H SAE 8 – 876711
See section J for housing details.
6 Special features
2 3
Description Operation
The MRV3-16 is 2a 3-way,
3 This valve will direct flow operator 90°, flow will cross-over transition, all
2 or 3 position, manual between ports 1 and 3 be directed between ports are blocked.
semi-rotary directional and block port 2 in one ports 1 and 2 and port 3
screw-in cartridge valve. position. By turning the will be blocked. During
1
111 0 0
0 2 4 6 8 10 12 14 16
Flow - USgpm (105 SUS oil @ 120°F)
Flow- --L/min
Flow
Flow L/min(21,8
L/min (21,8cSt
(21,8 cStoil
cSt oil@@
oil @49°C)
49°C)
49°C)
000 10
10
10 20 20
20 30
30
30 40
40
40 50
50
50 60
60
60
80
80 666
psi
80
Drop - psi
Pressure Drop- -psi
bar
Drop - bar
Pressure Drop- -bar
60
PressureDrop
60
60 444
PressureDrop
Pressure
40
40
40
Pressure
222
D-6 20
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4
20 September, 2007
20
Model Code MRV3-16
1 2 3 4 5 6
D
1Function 4 Manual operators 5 Port size
MRV3 - Manual rotary valve O - No operator O - Cartridge only
D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
2 Size D2 - Lever (2-position Aluminum Aluminum
16 - 16 Size detent)* Light duty Fatigue rated
K - Knob (2-position, 12T SAE 12 566152 –
no detent) 6B 3/4” BSPP 02-175465 –
3 Seals *Light duty housing only
10H SAE 10 – 876721
Blank - Buna-N 12H SAE 12 – 876723
V - Viton®
4G 1/2” BSPP – 876720
8G 3/4” BSPP – 876722
See section J for housing details..
6 Special features
00 - None
Dimensions (Only required if valve has
Arrow can be relocated by special features, omitted
mm (inch) MRVthe 3 -**domed
(V)relocated
-K nut by
slackening
Arrow can be if “00”)
Torque cartridge in and turning thebethe
slackening
Arrow can plate.domed
relocated nut
by slackening
the turning
Re-tighten
and domed
nut.nuttheandplate.
turning the plate.
aluminum housing Re-tighten nut.
Re-tighten nut.
108-122 Nm (80-90 ft. lbs) 61,0
(2.40)61,0 MRV3-**(V)-D(2)
Lo
(2.40) fo
90° Port 3 to 1
Port 3 to 1 45° in
90°
Locating Pin 45° 24,9 ± 0.05
Installation 58,0 (0.9824,9 ±0
± 0.00
(2.28)58,0 (0.98 ±
Locating pin hole, (2.28)
four optional slots 45°
in detent plate Port 1 to 2 45° Mid position
11,1 (0.43) (not Mid
for position
24,9 ± 0.05 11,1 (0.43) Port 1 to 2 105 (4 .13) 2-position
(not for
(0.98 ± 0.002) 11,0 (0.438) 105 (4 .13) models)
2-position
53,0 Ø
11,0 (0.438) models) (#
(2.08)53,0
(2.08) d
position 38,1 (1.0. 50) hex 76,0 (0
for 38,1 (1.0. 50) hex (3.0) 76,0 in
sition (3.0) Locating pin
els) 1.3125 " -12 Th d. Locating pin
Ø 3,45 3,50
(#29 or 0.136) 73,0 3 1.3125 " -12 Th d.
drill x 4,8 (2.87)73,0 3
(0.187) deep (2.87) 2
in mating housing 2
pin
1
1 Ø 26,95 (1.061)
Ø 26,95
Ø 28,55 (1.061)
(1.124)
Ø 28,55 (1.124)
4 2
3 1
Description Operation
The MRV4-10 is a 4-way, This valve will direct flow operator 90°, flow will be transition, ports 2 and 4
2 or 3 position,
4 manual
2 between ports 1 and 2 directed between ports are blocked and ports
semi-rotary directional and ports 3 and 4 in one 1 and 4 and port 3 to port 1 and 3 are connected.
screw-in cartridge valve. position. By turning the 2. During the cross-over
3
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curves
2 0 5 10
Cartridge only 150 10
A
14
Pressure Drop - bar
8
Pressure Drop - psi
100
3 6
A - Port 3 to 4
or 3 to 2 Flow - L/min (21,8 cSt oil @ 49°C)
B
2 B - Port 4 to 1 0 5 10 4
50150 10
or 2 to 1
A 2
1
Pressure Drop - bar
8
Pressure Drop - psi
0100 0
1 0 2 3 6
Flow - L/min (21,8 cSt oil @ 49°C)
Flow - USgpm (105 SUS oil @ 120°F) B
0 5 10 4
150 50 10
A
2
sure Drop - bar
8
sure Drop - psi
100
0 0
6
D-8 0
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 1 2 3
B
Flow - USgpm (105 SUS oil @ 120°F)
4
Model Code MRV4-10
1 2 3 4 5 6
D
1Function 4 Manual operators 5 Port size
MRV4 - Manual rotary valve O - No operator O - Cartridge only
4 way D - Lever (3-position
detent)* CODE PORT SIZE HOUSING NUMBER
D2 - Lever (2-position Aluminum Aluminum
2 Size detent)* Light duty Fatigue rated
10 - 10 Size E - Ball (3-position 3B 3/8” BSPP 02-179705 –
detent)* 6T SAE 6 566161 –
E2 - Ball (2-position
2G 1/4” BSPP – 876709
3 Seals detent)*
K - Knob (2-position, 3G 3/8” BSPP – 876715
Blank - Buna-N
no detent) 6H SAE 6 – 876708
V - Viton®
*Light duty housing only. 8H SAE 8 – 876713
See section J for housing details.
8,1 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-9
50)
MRV4-16
Manual rotary valve
4 2
3 1
Description Operation
The MRV4-16 is a 4-way, This valve will direct flow operator 90°, flow will be transition, ports 2 and 4
4 2
2 or 3 position, manual between ports 1 and 2 directed between ports are blocked and ports
semi-rotary directional and ports 3 and 4 in one 1 and 4 and ports 3 and 2. 1 and 3 are open to each
screw-in cartridge valve. position. By turning the During the cross-over other.
3 1
Functional Symbol RATINGS AND SPECIFICATIONS
3 position models Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 45 L/min (12 USgpm)
Internal leakage 164cc/min (10in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
3 1
Manual operators D - Lever (3-position detent)*
D2 - Lever (2-position detent)*
Sectional View * Light duty housing only. K - Knob (2-position, no detent)
Cavity C-16-4
4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
3 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
2 Weight cartridge only 0,65 kg (1.43 lbs)
Seal kit 889634 (Buna-N)
889638 (Viton®)
Viton is a registered trademark of E.I. DuPont
1
2
8
100
1 4 A 6
A - Port 3 to 4
or 3 to 2 50 4
3
B - Port 4 to 1 Flow - L/min (21,8 cSt oil @ 49°C) B 2
or 2 to 1
2 0 5 10 15 20 30 40 50
0 0
150 10
0 1 2 3 4 5 10
Pressure Drop - bar
Pressure Drop - psi
0 0
0 1 2 3 4 5 10 8
100
Flow - USgpm (105 SUS oil @ 120°F)A 6
D-10 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
50 4
Model Code MRV4-16
1 2 3 4 5 6
6 Special features
Dimensions
mm (inch)
00 - None
(Only required if valve has
Torque cartridge in MRV4-**(V)-D(2) special features, omitted
aluminum housing Port Port
3 to 34 to
and 2 to 21 to 1
4 and if “00”)
Port 3 to 4 and
108-122 Nm (80-90 ft. lbs) 45° 45°
Arrow can be relocated
Arrow can
by slackening thebedomed
relocated
by turning
slackening 58,058,0 Arrow can be relocated
nut and the the domed
plate. by slackening the domed 58,0
nut and
Re-tighten nut.turning the plate. (2.28)
(2.28) nut and turning the plate.
Re-tighten nut. Locating
Re-tighten nut. pin hole,
Locating pin hole, (2.28)
45° 45° Mid Mid fourfour
optional slotsslots
optional
position in detent plateplate
in detent
PortPort
3 to 32 to 2 position
and and
4 to41to 1 105,0 Port 3 to
1,061,0 105,0 24.924.9
?± 0.05
?± 0.05
Lo90°
catin90°
g Pin (4.13) 61,0 and 4 to
2.4)(2.4) 11,111,1
(0.438) (4.13) (0.980 ?± 0.002)
(0.980 90°
Installation (0.438) (2.4) ?± 0.002) 11,1 (0.438)
4 2
3 1
Description Operation
The MRV5-10 is a 4-way, This valve will direct flow operator 90°, flow will be
3 position, manual semi- between ports 1 and 2 directed between ports
MRV5-16
rotary directional screw-in and ports 3 and 4 in one 1 and 4 and port 3 to 2. Manual rotary valve
cartridge4valve. 2 position. By turning the During the cross-over
2
4 8
100
1 A - Port 3 to 4 6
3 or 3 to 2 B
50 4
B - Port 4 to 1
2 C
C - Port 2 to 1 2
Flow - L/min (21,8 cSt oil @ 49°C)
0 0 2 4 6 8 10 0
1
0 0.5 1 1.5 2 2.5 12 3
150 Flow - USgpm (105 SUS oil @ 120°F)A 10
Drop - bar
Drop - psi
B 12
50
150 4
A 10
bar
psi
C
2
8
100 0
0
6
D-12 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4
0 September,12007
0.5 1.5 2 2.5 B 3
50 4
Flow - USgpm (105 SUS oil @ 120°F)
MR V5-10
Model Code MRV5-10
Model Code M
Model Code
1 2 3 4 5 6
6 Special features
4 2
3 1
Description Operation
The MRV5-16 is a 4-way, This valve will direct flow operator 90°, flow will be transition, all ports are
3 position, manual semi- between ports 1 and 2 directed between ports blocked.
rotary directional screw-in and ports 3 and 4 in one 1 and 4 and ports 3 and 2.
cartridge 4valve. 2 position and by turning the During the cross-over
2 8
4
100
6
A - Port 3 to 4
1 3 or 3 to 2 A
4
B - Port 4 to 1 50
2 or 2 to 1 2
B
0 Flow - L/min (21,8 cSt oil @ 49°C) 0
1 0 0 10 2.5 20 5 30 7.5 4010 12
Flow - USgpm (105 SUS oil @ 120°F)
150 10
Drop - bar
Drop - psi
150 104
50
bar
psi
82
B
100
0 60
D-14 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 A
0 2.5 5 7.5 10 12 4
50
Model Code MRV5-16
1 2 3 4 5 6
D
1 Function 3 Seals 5 Port size
MRV5 - Manual rotary valve Blank - Buna-N O - Cartridge only
4 way V - Viton®
CODE PORT SIZE HOUSING NUMBER
2 4 Aluminum Aluminum
Size Manual operators Light duty Fatigue rated
16 - 16 Size O - No operator 12T SAE 12 566411 –
D - Lever (3-position
detent)* 6B 3/4” BSPP 02-175468 –
*Light duty housing only. 10H SAE 10 – 876729
12H SAE 12 – 876731
4G 1/2” BSPP – 876728
6G 3/4” BSPP – 876730
See section J for housing details.
6 Special features
Dimensions 00 - None
mm (inch) Port (Only required if valve has
Port 3
3 to
to 4
4 and 2 to
and 2 to 1
1
special features, omitted
Torque cartridge in Arrow
Arrow can
can be
be
relocated
relocated by
by if “00”)
aluminum housing slackening
slackening the
the
45°
45°
108-122 Nm (80-90 ft. lbs) domed
domed nut
nut and
and
turning
turning the
the plate
plate
Mid position
Mid position
Re-tighten
Re-tighten nut.
nut. 58,0
58,0
(2.28)
(2.28)
Locating Pin
45°
45°
Installation
Port
Port 3
3 to
to 2
2
Locating pin hole, 105
105
and
and 44 to
to 1
1
four optional slots (4.13)
(4.13)
in detent plate
11,1
11,1 (0.43)
(0.43)
24,9 ± 0.05
(0.980 ± 0.002) 77
77,0
,0 Locating pin
pin hole
hole
(3.03) Locating
(3.03) four optional slot
four optional slot
in detent
in detent plate
plate
Locating pin
Locating pin
1.312"-12
1.312"-12 Thd.
Thd.
38,1 (1.5)
(1.5) hh ex
ex 24,9 ±
24,9 ±0.05
0.05
4 38,1 (0.980 ±
±0.002)
0.002)
Ø 3,45/3,50 4 (0.980
101,6
101,6
(#29 or 0.136) (4.0)
drill x 4,8 (4.0) 3
3
(0.187) deep
in mating housing
2
2
ØØ 3,45/3,50
3,45/3,5
1
1 (#29 or 0.13
0.1
Ø 25,37
Ø 25,37 (0.999)
(0.999) (#29 or
drill xx 4,8
drill 4,8
Ø 26,95 (1.061)
Ø 26,95 (1.061) (0.187) deedee
15 (0.187)
Ø 28,55
28,55 (1.124)
(1.124) in mating
in mating hh
Ø
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-15
MRV6-10
Manual rotary valve
4 2
3 1
Description Operation
The MRV6-10 is a 4-way, This valve will direct flow operator 90°, flow will be transition all ports 1, 3 and
3 position, manual semi- between ports 1 and 2 directed between ports 4 are open to each other
rotary directional screw-in and ports 3 and 4 in one 1 and 4 and port 3 to 2. and port 2 is blocked.
cartridge valve. position. By turning the During the cross-over
4 2
4
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curves
3 0 2 4 6 8 10
Cartridge only 12
150
4 2 A 10
Pressure Drop - bar
Pressure Drop - psi
8
3 100
A - Port 3 to 4
1 or 3 to 2 6
B
2 B - Port 4 to 1 4
50
C - Port 2 to 1 C 2
Flow - L/min (21,8 cSt oil @ 49°C)
1 0
0 0 2 4 6 8 10
0 0.5 1 2.5 2 2.5 12 3
150 Flow - USgpm (105 SUS oil @ 120°F)
A 10
Flow - L/min (21,8 cSt oil @ 49°C)
Pressure Drop - bar
Pressure Drop - psi
0 2 4 6 8 10 8
100 12
6 16
150 B
A 10
4
ssure Drop - bar
essure Drop - psi
50
C 8
100 2
6
D-16 0
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 B 0
0 0.5 1 2.5 2 2.5 34
50
Model Code MRV6-10
1 2 3 4 5 6
6 Special features
CF EF
4 2
LS 5 1
PFRD-XX
Description Operation
The MLV9-12-A
3 P is a 4-way, In the center position, this In position 1, flow is direct- In position 2, flow is direct-
3-position, direct acting, valve allows flow from port ed from port 3 to port 2 ed from port 3 to port 4
spool CF
type directional
EF 3 to port 1 and blocks ports and from port 4 to port 1. and from port 2 to port 1.
control4valve.2 2 and 4.
LS 5 1
PFRS-XX
3 P
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
2 4 Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
SV9-8A
Fatigue pressure 3,000 psi per NFPA/T2-6-1 R2-2000
3 1 Rated burst pressure (626 bar) 9090 psi per NFPA/T2-6-1 R2-2000
Max flow 60 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C-12-4
2 4 Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
SV9-8B
Filtration Cleanliness code 18/16/13
Sectional View
3 1
Housing material (standard) Aluminum
Weight .57 kg (1.25 lbs)
Seal Kit 9900171-000 (Buna-N), 9900172 (Viton)
Viton is a registered trademark of E.I. DuPont
Internal Leakage 246 cm3/min (15 in3/min) max. @ 210 bar (3000psi)
2 4
Endurance tested to 1 million cycles at full rated flow and pressure.
SV9-8E
3 1
Flow - L/min
19 38 60
400 28
4
2 4
300 21
Pressure Drop - psi
SV9-8F
A
3 1
3 200 14
B
100 7
2
0
0 5 10 15
A - 3-2 Flow - USgpm
1 B - 4-1
LS 5 1
PFRD-XX
3 P
CF EF
4 2
LS 5 1
PFRS-XX
Description Operation
3 P
The MLV9-12-B is a 4-way, In the center position, all In position 1, flow is direct- In position 2, flow is direct-
3-position, direct acting, ports are open to each ed from port 3 to port 4 ed from port 3 to port 2
spool type directional other. and from port 2 to port 1. and from port 4 to port 1.
control2valve. 4
D
SV9-8A
3 1
3 1
Flow - L/min
19 38 60
400 28
4
300 21
Pressure Drop - psi
A
3
200 14
B
100 7
2
0
1 0 5 10 15
A - 3-2 Flow - USgpm
B - 4-1
LS 5 1
PFRS-XX
3 P
2 4
SV9-8A
Description
3 1 Operation
The MLV9-12-E is a 4-way, In the center position, all In position 1, flow is direct- In position 2, flow is direct-
3-position, direct acting, ports are blocked. ed from port 3 to port 4 ed from port 3 to port 2
spool type directional and fromport 2 to port 1. and from port 4 to port 1.
control2 valve4.
SV9-8B
3 1
Flow - L/min
19 38 60
400 28
300 21
Pressure Drop - psi
A
200 14
4
B
100 7
3
0
0 5 10 15
2
A - 3-2 Flow - USgpm
B - 4-1
1
MLV9-12-F
2 4
4-Way, 3-Position, screw-in cartridge manual lever valve
SV9-8A
3 1
2 4
SV9-8B
3 1
Description Operation
The MLV9-12-F is a 4-way, In the center position, port In position1, flow is direct- In position 2, flow is direct-
3-position, direct acting, 1, port 2, and port 4 are ed from port 3 to port 4 ed from port 3 to port 2
spool type directional con- open to each other while and from port 2 to port 1. and from port 4 to port 1.
trol valve.2 4 port 3 is blocked.
D
SV9-8E
3 1
Flow - L/min
19 38 60
400 28
4
300 21
Pressure Drop - psi
3 200 A 14
B
100 7
2
0
0 5 10 15
A - 3-2 Flow - USgpm
1
B - 4-1
2 4
MLV9 – 12 – * – * – * – L – * – *** – **
1 2 3 4 35 1 6 7 8 9
2 4
2 4 2 4
1 Function
4 Spool Center Condition 9 Lever Position
MLV9 - Manual Lever Valve 3
3 1
1
3 1 00 - 90°
A B 01 - 45°
2 Size
2 4 2 4 02 - 0°
12 - 12 Size 2 4 2 4
03 - 135°
3 Seal Material
04 - 180°
N - Buna N 3 1
33 11 3 1
See page D-35 for lever position
V - Viton
E F
2 4 2 4
2 4 2 4
3 1 3 1
3 1 3 1
5
Dentent Option
2 4 2 4
2 4
O - Spring Return
6 Lever
3 1 3 1
3L - Lever
1
7
2 Housing
4 Material
Blank - Cartridge only
A - Aluminum
38 1
Port Size
CODE PORT SIZE HOUSING NUMBER
Aluminum
0 Cartridge Only
A4G 1/2" BSPP 5986431-001
A6G 3/4" BSPP 5986432-001
A8H SAE 8 5986433-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001
See section J for housing details.
Dimensions
mm (inch)
SPARE PARTS
Lever 21113
Lever Position
WARNING
Maintain 5-8Nm (4-6 ft. lbs)
maximum torque on valve
tube nut. Overtightening
may cause valve failure.
Description Operation
The MPV1-10 is a 2-way, This valve blocks flow form
2
2 position, manually oper- port 2 to port 1 and will
ated, normally closed, allow flow form port 1 to
pull-to-open, directional port 2 when the spring
screw-in cartridge valve. bias is overcome.
1
4
50
1
40 3
Caution 30 2
Back pressure of 20 Flow - L/min (21,8 cSt oil @ 49°C)
• 1
16 bar (240 psi) 10
will unseat the poppet. 0 10 20 30 40 50
070 50
600 5 10
Pressure Drop - bar
Pressure Drop - psi
4
50 Flow - USgpm (105 SUS oil @ 120°F)
40 3
30 2
20
1
10
0 0
0 5 10
Flow - USgpm (105 SUS oil @ 120°F)
D-38 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
Model Code MPV1-10
1 2 3 4 5 6
D
1Function 3 Seals 5 Port size
MPV1 - Manual pull valve Blank - Buna-N O - Cartridge only
V - Viton®
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
4 Type Light duty Fatigue rated
10 - 10 Size
T - Stem only 3B 3/8” BSPP 02-175462 –
K - Knob 6T SAE 6 566151 –
2G 1/4” BSPP – 876702
3G 3/8” BSPP – 876703
6H SAE 6 – 876700
8H SAE 8 – 876701
See section J for housing details.
6 Special features
00 - None SS - 316 Stainless Steel
(Only required if valve has external components
special features, omitted
if “00”)
Dimensions
mm (inch)
41,3
(1.63)
25,4 (1.0) hex
1
Ø 15,80 (0.622)
Description Operation
The MPV3-10 is a 2-way, This valve blocks flow form the valve is actuated free
2 position, manually operat- port 2 to port 1 and will flow is allowed in both
ed, normally closed, pull-to- allow flow form port 1 to directions.
open, directional screw-in port 2 when the spring
cartridge valve, with detent. bias is overcome. When
4
50
2 40 3
30 2
1 20
1
10
Caution 0 0
• Back pressure of 0 5 10
16 bar (240 psi)
will unseat the poppet. Flow - USgpm (105 SUS oil @ 120°F)
MPV3 10 * ** 00
1 2 3 4 5
D
1 Function 3 Seals 5 Special features
MPV3 - Manual pull valve, N - Buna-N 00 - None
with detent V - Viton®0 (Only required if valve has
special features, omitted
if “00”)
2 Size 4 Port size
10 - 10 Size 00 - Cartridge only
Dimensions 38,1
mm (inch) (1.500)
3,18
Torque cartridge in (0.125)
aluminum housing travel
47-54 Nm (35-40 ft. lbs)
52,2
(2.134)
85,9
(3.381) 25,4
(1.0)
Hex
0.875"-14 Thd.
31,7
(1.25) 2
1
Ø 15,80 (0.622)
Description Operation
The MSV1-12 is a 3-way, 2 In the normal position, the In the actuated position,
position manual ‘push and valve allows flow from port flow is allowed from port 3
twist’ to actuate type valve. 1 to port 2 while port 3 is to port 1 while port 2 is
blocked. blocked.
Pressure Drop
Curve
Cartridge only A - P1 to P2
B - P3 to P1
160
3 140
120
Pressure Drop - psi
100
2
B
80
A
60
1
40
20
0
0 1 2 3 4 5 6 7 8 9 10 11
Flow (gpm)
MSV1 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV1 - 3-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 10 Size
5 Port Size
3 Seals
0 - Cartridge only
Blank - Buna-N
V - Viton®0 CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 02-161816
A12H SAE 12 02-160646
Dimensions
mm (inch)
38,1 (1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
67,8 (2.67)
22,1
(.870)
23,9
(.940)
Description Operation
The MSV2-12 is a 3-way, 2 In the normal position, the In the actuated position,
position manual ‘push and valve allows flow from port flow is allowed from port 2
twist’ to acutate type valve. 1 to port 3 while port 2 is to port 1 while port 3 is
blocked. blocked.
Pressure Drop
Curve
A - P2 to P1
Cartridge only
B - P1 to P3
160
140
3
120
Pressure Drop - psi
100
2 B
80
A
60
1
40
20
0
0 1 2 3 4 5 6 7 8 9 10 11
Flow (gpm)
MSV2 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV2 - 3-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size
3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 02-161816
A12H SAE 12 02-160646
Dimensions
mm (inch)
38,1 (1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
67,8 (2.67)
22,1
(.870)
23,9
(.940)
Description Operation
The MSV5-12 is a 3-way, 2 In the normal position, the In the actuated position,
position manual ‘push and valve allows flow from port flow is allowed from port 3
twist’ to actuate type valve. 2 to port 1 while port 3 is to port 2 while port 1 is
blocked. blocked.
Pressure Drop
Curve
Cartridge only A - P2 to P1
B - P3 to P2
160
140
3
120
Pressure Drop - psi
100
2 B
80
A
60
1
40
20
0
0 1 2 3 4 5 6 7 8 9 10 11
Flow (gpm)
MSV5 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV5 - 3-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size
3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 02-161816
A12H SAE 12 02-160646
Dimensions
mm (inch)
38,1 (1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
67,8 (2.67)
22,1
(.870)
23,9
(.940)
Description Operation
The MSV3-12 is a 4-way, 2 In the normal position, all allowed from port 3 to port
position manual ‘push and ports are blocked. In the 4 and from port 2 to port 1.
twist’ to actuate type valve. actuated position, flow is
Pressure Drop
Curve
Cartridge only A - P3 to P4
B - P2 to P1
160
4
140
3 120
Pressure Drop - psi
100
2 80 B
60 A
1 40
20
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow (gpm)
MSV3 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV3 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size
3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001
Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
90,9 (3.58)
20,6
(.810)
22,1
(.872)
23,7
(.935)
Description Operation
The MSV4-12 is a 4-way, 2 In the normal position, flow In the actuated position, all
position manual ‘push and is allowed from port 3 to ports are blocked.
twist’ to actuate type valve. port 4 and from port 2 to
port 1.
Pressure Drop
Curve
Cartridge only A - P3 to P4
B - P2 to P1
160
4
140
3 120
Pressure Drop - psi
100
2 80 B
60 A
1 40
20
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow (gpm)
MSV4 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV3 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size
3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001
Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
90,9 (3.58)
20,6
(.810)
22,1
(.872)
23,7
(.935)
Description Operation
The MSV6-12 is a 4-way, 2 In the normal position, all port 2 and from port 4 to
position manual ‘push and ports are blocked. In the port 1.
twist’ to actuate type valve. actuated position, flow is
allowed from port 3 to
Pressure Drop
Curve
Cartridge only A - P4 to P1
B - P3 to P2
4 160
140
3
120
Pressure Drop - psi
100
2 B
80
60 A
1
40
20
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Flow (gpm)
MSV6 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV6 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size
3 5 Port Size
Seals
Blank - Buna-N 0 - Cartridge only
V - Viton®0
CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001
Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
90,9 (3.58)
20,6
(.810)
22,1
(.872)
23,7
(.935)
Description Operation
The MSV7-12 is a 4-way, 2 In the normal position, flow In the actuated position,
position manual ‘push and is allowed from port 3 to flow is allowed from port 3
twist’ to actuate type valve. port 4 and from port 2 to to port 2 and from port 4 to
port 1. port 1.
Pressure Drop
Curve
Cartridge only A - P4 to P1, P3 to P2
B - P2 to P1, P3 to P4
4 160
140
3 120
Pressure Drop - psi
100
2 B
80
A
60
1
40
20
0
0 1 2 3 4 5 6 7 8 9 10 11 12
Flow (gpm)
MSV7 – 12 * – L– ****– **
1 2 3 4 5 6
6
D
1 Function 4 Actuation Option Special features
MSV7 - 4-way, 2 position L - 2 postion ‘push and twist’ Blank - No special features
manual push valve actuation
E - Emergency stop actuation
2 Size N - No Detent
12 - 12 Size
5 Port Size
3 Seals
0 - Cartridge only
Blank - Buna-N
V - Viton®0 CODE PORT SIZE HOUSING NUMBER
Aluminum
A6G 3/4” BSPP 5986432-001
A10H SAE 10 5986434-001
A12H SAE 12 5986436-001
Dimensions
mm (inch) 38,1
(1.50)
Torque cartridge in
aluminum housing
81-95 Nm (60-70 ft. lbs)
68,1 (2.68)
90,9 (3.58)
20,6
(.810)
22,1
(.872)
23,7
(.935)
1 3
1 3
Description Operation
The DSV2-8-B is a direct The DSV2-8-B shuttle valve
acting, ball2type, shuttle senses the higher of two
valve. pressures at port 3 or port
1 and directs it to port 2.
2
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curves
0 8 16 22
Pressure Drop - psi
16
1 200 0 0
0 2 4 126
150
Flow - USgpm (105 SUS oil @A120°F)
8
100 B
Flow - L/min (21,8 cSt oil @ 49°C)
50 0 4
8 16 22 20
300 20
0 0
2500 2 4 6
Pressure Drop - bar
Pressure Drop - psi
50 4
Model Code DSV2-8
1 2 3 4 5 6 7
D
1 Function 4 Style 6
Port size
DSV2 - Shuttle valve B - Ball O - Cartridge only
7Special features
00 - None
(Only required if valve has
special features, omitted
if “00”)
SS - 316TI Stainless Steel
external components
40,6 3
(1.60)
Ø 14,2 (0.559)
Description Operation
The PSV2-8 is an externally The PSV2-8 remains closed
piloted, direct acting, sliding until the predetermined
spool, adjustable, pressure pressure is reached at port
sequence valve. 1, which then allows flow
from port 3 to port 2.
100 7
0 0
0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120ºF)
1 2 3 4 5 6 7 8 9
Dimensions
mm (inch)
Torque cartridge in
aluminum or steel housing "S" Adjustment
4,0 (0.15) hex
"C" Adjustment
12,7 (0.50) hex K option knob
Ø 31,8 (1.25)
68,3 76,5 79,2 nominal
(2.68) (3.02) (3.12)
53,8
(2.13) Full
71,3 out
(2.81)
Full 22,2 (0.87) hex
out
0.750"-16Thd.
3
40,9
(1.61)
2
1
Ø14,2 (0.559)
Ø15,8 (0.622)
Description Operation
The PSV4-8 is an external The PSV4-8 remains closed
pilot, direct acting, sliding until a predetermined
spool, adjustable, pressure pressure is applied at pilot
sequence valve. port 1, which then allows
flow from port 3 to port 2.
200 14
100 7
0 0
0 1 2 3 4
1 2 3 4 5 6 7 8 9
Dimensions
mm (inch)
"S" Adjustment
"S" Adjustment
Torque cartridge in 4,0 hex
4,0(0.15)
hex (0.15)
steel or aluminum
"C"Adjustment
"C"Adjustment
housing 34-41 Nm
(25-30 ft. lbs) 12,7 (0.50)
12,7 (0.50)
hex hex K option
K option
knob knob
Ø 31,8
Ø (1.25)
31,8 (1.25)
68,3 68,3 76,5 76,5
79,2 79,2 nominal
nominal
(2.68)(2.68) (3.02)(3.02)
53,8 53,8 (3.12)(3.12)
(2.13)(2.13) 71,3 71,3 Full Full
(2.81)(2.81) out out
Full Full
out out 22,2 (0.87)
22,2 (0.87)
hex hex
Aluminum
0.750"-16
0.750"-16
Thd. Thd. housings can
3 3 40,9 40,9
• be used for
(1.61)(1.61)
pressures up
2 2
to 210 bar (3000 psi).
Steel housings must be
1 1 used for operating pres-
Ø 14,2
Ø (0.559)
14,2 (0.559)
Ø 15,8
Ø (0.622)
15,8 (0.622) sures above 210 bar
(3000 psi).
Description Operation
The PCS3-12 is a This valve, when used with flow. This is based on what changes downstream on
screw-in, pressure either a fixed or variable ever pressure differential is port 2.
compensator cartridge. orifice between port 1 and chosen. Flow out of port 2,
port 3, maintains a constant regardless of pressure,
C
0.200
3
0.150
2 0.100
0.050
1
0.000
0 5 10 15
FLOW (GPM)
1 2 3 4 5 6 7
Dimensions
mm (inch)
I
Torque into aluminum 31,7 (1.25) HEX
housing to 81-95Nm
(60-70 ft. lbs) 33,3 (1.31)
1 1/16-12 UNF -
2A THREAD
68,6 (2.70)
.873 ± .001
.935 ± .001
Description Operation
The PCS3-16 is a This valve, when used with flow. This is based on what- of pressure, changes
screw-in, pressure either a fixed or variable ever pressure differential is downstream on port 2.
compensator cartridge. orifice between port 1 and chosen. Flow out of port 2,
port 3, maintains a constant regardless
Sectional View
0.400 10
Approx. orifice diameter - mm
0.350
3 A 8
0.300
B
0.250
C 6
0.200
0.150 4
2
0.100
2
0.050
0 0
0 3 6 9 12 15 18 21 24 27 30
1 Controlled flow - USgpm (105 SUS oil @ 120° F)
1 2 3 4 5 6 7
Dimensions
mm (inch)
28,6 38,1 (1.50) hex
(1.12) I
Torque into aluminum
housing to 108-122 Nm
(80-90 ft. lbs)
1.312 -12 Thd.
73,0 3
(2.87)
1
26,95 (1.061)
28,55 (1.124)
Description Operation
The PCS3-20 is a This valve, when used with flow. This is based on what- pressure, changes down-
screw-in, pressure either a fixed or variable ori- ever pressure differential is stream on port 2.
compensator cartridge. fice between port 1 and chosen. Flow out of port 2,
port 3, maintains a constant regardless of
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 189 L/min (50 USgpm)
Functional Symbols Cavity C–20–3
Standard housing materials Customized housings are
necessary for close-coupling
Variable the compensator and orifice
or fixed
restrictor Temperature range -40° to 120°C (-40° to 248°F)
upstream Fluids All general purpose hydraulic fluids such as:
3 2
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
1 Weight cartridge only 0,88 kg (1.94 lbs)
Seal kits 889616 Buna-N
02-175433 Viton®
Viton is a registered trademark of E.I. DuPont
Sectional View
20
3 0.700
16
0.600
A
0.500 12
B
0.400
2 0.300 8
0.200
4
0.100
0 0
1 0 10 20 30 40 50
Controlled flow USgpm (105 SUS oil @ 120° F)
1 2 3 4 5 6 7
Dimensions
mm (inch)
3
98,4
(3.87)
2
1
33,30 (1.311)
36,47 (1.436)
3
1
2 4
Description Operation
The PTS2-16 is a 3-way, This valve allows flow spring bias is overcome. cross-over transition, all
2 position, pilot operated, between ports 2 and 3 At that time, flow is directed ports are blocked. The
directional screw-in car- while blocking port 4 until between ports 3 and 4 while spring chamber for this
3
tridge valve. sufficient pressure has been blocking port 2. During the valve is internally vented
1 applied to port 1 and the to port 4 (tank).
3
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curve
4 0 20 40 60 80 100 110
2 Cartridge only
6
80
5
Pressure Drop - bar
3 2
Pressure Drop - psi
70
1 to
60
or3 4
50 3
2 to
4 3
40 rt @ 49°C)
Flow - L/min (21,8 cStPooil
30 2
0 20 40 60 80 100 110
1 20
16
10
80
2 05
Drop - bar
Drop - psi
0
70
5 10 15 20 25 0 30 to 35
60 Flow - L/min (21,8 cSt oil @ 49°C) 3
or 4
50 Flow
0 - USgpm
20 40 (105
60SUS80oil @100 120°F)
3 110
to
t4 63
ssure Drop - Pressure
ssure Drop - Pressure
40 r
80 P o
30 36
52
bar
2
psi
70
20 to
3
60
10 or 41
50 3
0 to 0
D-64 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 4 3
40 0 5 10 15 20 r 25 t 30 35
30 Po
2
Model Code PTS2-16
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS2 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features
Dimensions
mm (inch) 28,6 38,1 (1.5) h ex
Torque cartridge in (1.12)
aluminum housing
47-54 Nm (35-40 ft. lbs) 1.312"-12 Thd.
101,6
(4.00)
3
1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)
3
1
Description 4 Operation
The PTS2-20 is a 3-way, This valve allows flow spring bias is overcome. cross-over transition, all
2 position, pilot operated, between ports 2 and 3 At that time, flow is directed ports are blocked. The
directional screw-in car- while blocking port 4 until between ports 3 and 4 while spring chamber for this
tridge valve. sufficient pressure has been blocking port 2. During the valve is vented internally
applied at port 1 and the to port 4 (tank).
3
Fun1ctional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
1 2
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
4 Rated flow 265 L/min (70 USgpm)
2 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
4 Pilot pressures 40 - 2,75 bar (40 psi)
4 80 - 5,5 bar (80 psi)
Pilot displacement volume 6,72 cm3 (0.41 in3)
Sectional View Cavity C-20-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
Seal kit 565916 (Buna-N)
1 889646 (Viton®)
Viton is a registered trademark of E.I. DuPont
4
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
Curve
4 3 0 40 80 200 210 220 240
Cartridge only
6
80
Pressure Drop - bar
Pressure Drop - psi
3 2 70 5
2
to
3
60 4
or
3
50
to
2 3
4
1 40
rt
Po
30 2
20
1
10 1
Flow - L/min (21,8 cSt oil @ 49°C)
0 0
0 40 80 200 210 220 240
0 10 20 30 40 50 60 70
Flow - L/min (21,8 cSt oil @ 49°C) 6
80 Flow - USgpm (105 SUS oil @ 120°F)
Pressure Drop - bar
Pressure Drop - psi
70
0 40 80 200 210 220 240 5
2
to
6
3
80 60 4
or
3
70 50 38
ssure Drop - bar
ssure Drop - psi
5
to
2
to
3
4
40
rt
60
Po
4
or
30 2
3
50
to
40
rt
10 1
Po
30 2
Model Code PTS2-20
1 2 3 4 5 6
D
1Function 4 Port size V - Viton®
PTS2 - Pilot to shift valve O - Cartridge only
5 Pilot to shift (nominal)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
40 - 2,75 bar (40 psi)
Light duty Fatigue rated 80 - 5,5 bar (80 psi)
20 - 20 Size
16T SAE 16 566412 –
8B 1” BSPP 02-175469 – 6 Special features
3 Seals 12H SAE 12 – 876745 00 - None
Blank - Buna-N 16H SAE 16 – 876747 (Only required if valve has
6G 3/4” BSPP – 876744 special features, omitted
8G 1” BSPP – 876746 if “00”)
See section J for housing details.
139,7
(5.50)
3
1
Ø 31,70 (1.248)
Ø 33,30 (1.311)
Ø 36,47 (1.436)
2
Description 4 Operation
The PTS3-16 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 2 and 3 while internally vented to port
tridge valve. sufficient pressure has been blocking port 4. During the 4 (tank).
3 applied to port 1 and the cross-over transition, all ports
1
Functional Symbol RATINGS AND SPECIFICATIONS
2 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
Typical application pressure (all ports) 210 bar (3000 psi)
4
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
2 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
4
Pilot pressures 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Sectional View Pilot displacement volume 1,97 cm3 (0.12 in3)
Cavity C-16-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
1 Seal kit 889634 (Buna-N)
889638 (Viton®)
4 Viton is a registered trademark of E.I. DuPont
3
to
60
3
1 4
or
3
50
to
2 3
4
40
rt
Po
30 2
1 20 Flow - L/min (21,8 cSt oil @ 49°C)
1
10 0 20 40 60 80 100 110
0 0 6
080 5 10 15 20 25 30 35
5
70 Flow - L/min (21,8 cSt oil @ 49°C)
Pressure Drop - bar
2
Pressure Drop - psi
60
3
0 20 40 60 80 100 110 4
or
6
3
50
to
80 3 42
4
40 5
rt
70
Po
30 2
to
6020
3
4
or
1
3
5010
to
40 0 0
rt
Po
30 0 5 10 15 20 25 30 35
Model Code PTS3-16
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS3 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features
Dimensions
mm (inch) 28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312"-12 Thd.
4
101,6
(4.00)
3
1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)
43
PTS3-20
Pilot to shift valve
3
1
Description 4 Operation
The PTS3-20 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 2 and 3 while vented internally to port 4
tridge valve. sufficient pressure has been blocking port 4. During the (tank).
3 applied to port 1 and the cross-over transition, all ports
1
70
Pressure Drop - bar
Pressure Drop - psi
to
3
3
60
or
4
3
1 50
to
2 3
4
40
rt
Po
30 2
20
1 Flow - L/min (21,8 cSt oil @ 49°C) 1
10
40 80 200 210 220 240
0 06
800 10 20 30 40 50 60 70
5
2
to
3
4
6
3
50
to
80
3 44
4
40
rt
5
2
70
essure Drop - bar
Po
ssure Drop - psi
to
30 2
3
60
or
20 4
3
50
to
10 1
3
4
40
rt
0 0
30 270
0 10 20 30 40 50 60
Model Code PTS3-20
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS3 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
Light duty Fatigue rated 6 Special features
20 - 20 Size
16T SAE 16 566412 – 00 - None
8B 1” BSPP 02-175469 – (Only required if valve has
3 Seals special features, omitted
12H SAE 12 – 876745
Blank - Buna-N if “00”)
16H SAE 16 – 876747
V - Viton®
6G 3/4” BSPP – 876744
8G 1” BSPP – 876746
See section J for housing details.
Dimensions
mm (inch) 47,6 (1. 875) hex
41,3
Torque cartridge in (1.62)
aluminum housing
128-155 Nm (95-115 ft. lbs)
1.625"-12 Thd.
4
139,7
(5.50)
3
Ø 31,70 (1.248)
Ø 33,30 (1.311)
Ø 36,47 (1.436)
3
1
2 4
Description Operation
The PTS1-10 is a 3-way, This valve allows flow spring bias is overcome. ports are blocked. The
2 position, pilot operated, between ports 2 and 3 At this time, flow is directed spring chamber for this
directional screw-in car-
3
while blocking port 4 until between port 3 and port 4 valve is externally vented
tridge
1 valve. sufficient pressure has been while blocking port 2. During to atmosphere.
applied to port 1 and the the cross-over transition, all
2 4
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3 Typical application pressure (all ports) 210 bar (3000 psi)
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 30 L/min (8 USgpm)
2 4 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Pilot displacement volume 0,49 cm3 (0.02 in3)
Cavity C-10-4
3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
2
Standard housing materials Aluminum
Weight cartridge only 0,14 kg (0.32 lbs)
4 Seal kit 889625 (Buna-N)
1 566080 (Viton®)
Viton is a registered trademark of E.I. DuPont
3
1 3 60
4
3
or
50
3
to
3
4
2 40
rt
Po
0
30 Flow - L/min (21,8 cSt oil @ 49 C)
5 10 15 20 25 302
20 5
1 70 1
2
10
to
60
04
3
0
or
50
3
0 1 2 3 4 5 6 7 8
to
0
Flow- USgpm
Flow - L/min (21,8 cSt oil
(105 SUS oil@@49 C)0F)
120 3
4
40
rt
5 10 15 20 25 30
Po
30 52
70
2
20 28
to
60
41
3
10
or
50
3
to
0
30
4
40 0 1 2 3 4 5 6 7 8
rt
Po
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS1 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
10 - 10 Size Light duty Fatigue rated
3B 3/8” BSPP 02-179705 – 6 Special features
Dimensions
25,4 (1.0) hex
mm (inch) 19,0
Torque cartridge in (0.75)
aluminum housing
47-54 Nm (35-40 ft. lbs) 0.875” - 14 Thd.
61,9
(2.44) 3
Ø 15,80 (0.622)
Ø 17,40 (0.685)
Ø 18,97 (0.747)
29
PTS1-16
Pilot to shift valve
3
1
2 4
Description Operation
The PTS1-16 is a 3-way, This valve allows flow spring bias is overcome. over transition, all ports
2 position, pilot operated,
3 between ports 2 and 3 At this time, flow is are blocked. The spring
directional screw-in car- while blocking port 4 until directed between port 3 chamber for this valve is
1 valve.
tridge sufficient pressure has been and port 4 while blocking externally vented to
applied to port 1 and the port 2. During the cross- atmosphere.
2 4
Functional Symbol RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
3
Typical application pressure (all ports) 210 bar (3000 psi)
1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
2 4 Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
Sectional View 80 - 5,5 bar (80 psi)
4 160 - 11,0 bar (160 psi)
Pilot displacement volume 1,97 cm3 (0.12 in3)
3 Cavity C-16-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
2 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
4 Weight cartridge only 0,5 kg (1.12 lbs)
1 Seal kit 889634 (Buna-N)
889638 (Viton®)
3 Viton is a registered trademark of E.I. DuPont
to
Pressure Drop - psi
60 3 4
or
50 3
2 to
4
Flow - L/min (21,8 cSt oil @ 49t0C)
40 3
r
30 20 40 60 80 100 Po 110 2
1 20 6
80 1
70 10 5
2
Pressure Drop - bar
to
Pressure Drop - psi
60 0 0
3
0 5 10 15 20 o25 30 4 35
r
50 03
Flow - Flow
L/min- USgpm
(21,8 cSt(105
oil @SUS49 C) @ 1200F)
to oil
40 4 3
20 40 60 80 rt100 110
30 P o
62
8020 30
7010 2 51
sure Drop - bar
to
sure Drop - psi
60 0 3
r 40
o
50 0 5 10 15 20 253 30 35
to 3
40 t 4 @ 120 F)
D-58 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4
Flow - September,
USgpm (1052007 SUS oil 0
or
30 P 2
Model Code PTS1-16
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS1 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features
Dimensions
mm (inch) 38,1 (1.5) hex
28,6
Torque cartridge in
(1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs)
1.312”-14 Thd
101,6 3
(4.0)
1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)
3
1
2 4
Description Operation
The PTS1-20 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 2 and 3 At that time, flow is directed chamber for this valve is
directional screw-in car-
3 while blocking port 4 until between ports 3 and 4 while externally vented to atmos-
tridge valve. sufficient pressure has been blocking port 2. During the phere.
1 applied to port 1 and the cross-over transition, all ports
3
Pressure Drop Flow - L/min (21,8 cSt oil @ 490C)
Curve 0 20 40 60 80 100 110
42
Cartridge only 6
80
3 70 2 5
Pressure Drop - bar
1 to
Pressure Drop - psi
60 3
or 4
50 3
2 to
4 3
40
ort
P
30 Flow - L/min (21,8 cSt oil @ 490C) 2
1 20 0 20 40 60 80 100 110
16
10
80
0
70 2 5
Pressure Drop - bar
o
Pressure Drop - psi
10 20 30 40 600 50 603 t 70
r 4
Flow - L/min (21,8 cSt oil @ 493 0oC)
0
50 Flow - USgpm (105 SUS oil @ o120 F)
0 20 40 60 80 100 t 110
4 3
40
ort 6
80 P
30 2 32
70 2 5
ressure Drop - bar
20 to
essure Drop - psi
60 3 1
10 or 4
50 3
0 to
t 4 3
40 0 10 20 30 r
40 o 50 60 70
D-60 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
P
30 Flow - USgpm (105 SUS oil @ 1200F) 2
Model Code PTS1-20
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS1 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
Light duty Fatigue rated 6 Special features
20 - 20 Size
16T SAE 16 566412 – 00 - None
8B 1” BSPP 02-175469 – (Only required if valve has
3 Seals special features, omitted
12H SAE 12 – 876745
Blank - Buna-N if “00”)
16H SAE 16 – 876747
V - Viton®
6G 3/4” BSPP – 876744
8G 1” BSPP – 876746
See section J for housing details.
139,7
(5.5) 3
1
Ø 31,70 (1.248)
Ø 33.30 (1.311)
Ø 36,47 (1.436)
33
PTS5-10
Pilot to shift valve
2
4
3 1
Description Operation
The PTS5-10 is a 3-way, This valve allows flow spring bias is overcome. are blocked. The spring
2 position, pilot operated, between ports 1 and 2 At that time, flow is directed chamber for this valve is
directional screw-in car- while port 3 is blocked until between ports 2 and 3 while vented internally to port
tridge valve. sufficient pressure has been blocking port 1. During the 1.
2
applied at port 4 and the cross-over transition, all ports
4
80
Pressure Drop - psi
3 5
A - Port 3 to 2 60
1 B 4
B - Port 2 to 1
2 40 3
Flow - Flow
USgpm- L/min
(105 (21,8 cSt@oil120°F)
SUS oil @ 49°C)
5
060 2 4 6 8 10
100 B 4
7
A 3 48
40
6
ressure Drop - bar
80
ressure Drop - psi
2
20 5
60 1
B 4
0 0
D-76 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 40
September, 2007 3
0 1 2 3
2
Flow - USgpm (105 SUS oil @ 120°F)
Model Code PTS5-10
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS5 - Pilot to shift valve O - Cartridge only 50 - 3,45 bar (50 psi)
Dimensions 4
mm (inch)
0.875"-14 Thd.
46,0 3
(1.81)
1
Ø 15,80 (0.622)
Ø 17,40 ( 0.685)
2 4
Description Operation
The PTS5-16 is a 3-way, This valve allows flow spring bias is overcome. are open. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 3 and 2 while externally vented to
tridge valve. 3 sufficient pressure has been blocking port 4. During the atmosphere.
applied to port 1 and the cross-over transition, all ports
1
3
Pressure Drop Flow - L/min (21,8 cSt oil @ 49°C)
4
Curve 20 40 60 80 100 110
2
Cartridge only 6
80
3 70 5
Pressure Drop - bar
2
Pressure Drop - psi
1 60 to
3 4
or
2 50 3
to 3
40 t 4
r
30 Po cSt oil @ 49°C)2
Flow - L/min (21,8
20 20 40 60 80 100 110
1 1
10 6
80
0 0
0 70 5 5
Pressure Drop - bar
10 15 20 25 30 35 2
Pressure Drop - psi
o
60 Flow
Flow - L/min(105
- USgpm (21,8SUS
cSt oil
oil @ 49°C) 3 t
@ 120°F) 4
or
50 20 40 60 80 100 110 3
to 3
40 4 6
80 rt 50
30 Po 2
70 5
sure Drop - bar
2
sure Drop - psi
20 to
60 3 4 1
10 or
50 3 0
D-78 EATON Vickers Screw-In Cartridge Valves 0
V-VLOV-MC001-E4 September, 2007 to 3
40 0 5 10 t4
15 r20 25 30 35
Po
30
Model Code PTS5-16
1 2 3 4 5 6
D
1 Function 4 Port size V - Viton®
PTS5 - Pilot to shift valve O - Cartridge only
5 Pilot to shift (nominal)
CODE PORT SIZE HOUSING NUMBER
2 Size Aluminum Aluminum
40 - 2,75 bar (40 psi)
Light duty Fatigue rated 80 - 5,5 bar (80 psi)
16 - 16 Size
12T SAE 12 566411 – 160 - 11,0 bar (160 psi)
6B 3/4” BSPP 02-175468 –
3 Seals 10H SAE 10 – 876729 6 Special features
Blank - Buna-N 12H SAE 12 – 876731 00 - None
4G 1/2” BSPP – 876728 (Only required if valve has
6G 3/4” BSPP – 876730 special features, omitted
See section J for housing details.
if “00”)
101,6
(4.00) 3
1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)
51
PTS6-10
Pilot to shift valve
4 2
5
Descriptio3
n Operation
1
The PTS6-10 is a 4-way, This valve allows flow is overcome. At that time, blocked. The spring cham-
2 position, pilot operated, between ports 1 and 2 and flow is directed between ber for this valve is vented
directional screw-in car- ports 3 and 4 until sufficient ports 1 and 4 and ports 3 internally to port 1.
tridge valve. pressure has been applied and 2. During the cross-over
4 2 at port 5 and the spring bias transition, all ports are
5
Functional Symbol RATINGS AND SPECIFICATIONS
5 Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
4 2 Typical application pressure (all ports) 210 bar (3000 psi)
5 3 1 Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 23 L/min (6 USgpm)
Internal leakage 164 cc/min (10 in3/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
3 1 Pilot pressure 4,2 bar (60 psi)
Pilot displacement volume 0,49 cm3 (0.02 in3)
Sectional Vie4w Cavity C-10-4
Fluids All general purpose hydraulic fluids such as:
5 MIL-H-5606, SAE 10, SAE 20, etc.
3 Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
2 Weight cartridge only 0,15 kg (0.33 lbs)
5 Seal kit 889625 (Buna-N)
566080 (Viton®)
1 Viton is a registered trademark of E.I. DuPont
5
3 A - Port 3 to 4
1 B - Port 4 to 1 60 4
C - Port 3 to 2 D
2
D - Port 2 to 1 3
40 Flow - L/min (21,8 cSt oil @ 49°C)
0 4 8 12 16 20 2
1
20 100 7
A 1B
Flow - L/min (21,8 cSt oil @ 49°C) 6
0 0
0 80 10 24 38 412 516 620 C
Pressure Drop - bar
Pressure Drop - psi
5
Flow
100- USgpm (105 SUS oil @ 120°F) 7
60 A B
4
D 6
52
80 3
C
sure Drop - bar
sure Drop - psi
40 5
2
60 4
20 D
D-80 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 1
3
40
Model Code PTS6-10
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS6 - Pilot to shift valve O - Cartridge only 60 - 4,2 bar (60 psi)
0.875"-14 Thd.
61,9 4
(2.43)
3
1
Ø 15,80 (0.622)
Ø 17,40 ( 0.685)
Ø 18,97 (0.747)
53
EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007 D-81
PTS6-16
Pilot to shift valve
Description 2 4 Operation
The PTS6-16 is a 3-way, This valve allows flow spring bias is overcome. are open. The spring
2 position, pilot operated, between ports 3 and 4 At that time, flow is directed chamber for this valve is
directional screw-in car- while blocking port 2 until between ports 3 and 2 while externally vented to Port 4
tridge valve. 3 sufficient pressure has been blocking port 4. During the (tank).
applied to port 1 and the cross-over transition, all ports
1
70
Pressure Drop - psi
to
60
or3 4
2 3
50
to 3
40 t 4
Flow - L/min (21,8 cSt oilr @ 49°C)
30 Po
1 0 20 40 60 80 100 110 2
20
61
80
10
2 50
Pressure Drop - bar
700
Pressure Drop - psi
to
60 0Flow5- L/min
10 (21,8
15 cSt 20
oil @ 49°C)
25 30 3 35 4
or
500 Flow20 - USgpm
40 60(105 80
SUS oil 3
100@o120°F)110
t 3
40 4 6
o rt
80 P
30 2 54
2 5
ssure Drop - bar
70
ssure Drop - psi
20 to
3
60
10 or 4 1
50 3
0 to 3 0
D-82 EATON Vickers Screw-In Cartridge Valves 40 0 September,
V-VLOV-MC001-E4 2007 t 4
5 10 15 20or 25 30 35
30 P
Flow - USgpm (105 SUS oil @ 120°F) 2
Model Code PTS6-16
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS6 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
16 - 16 Size Light duty Fatigue rated
12T SAE 12 566411 – 6 Special features
Dimensions
mm (inch) 28,6 38,1 (1.50) hex
Torque cartridge in (1.12)
aluminum housing
108-122 Nm (80-90 ft. lbs) 1.312"-12 Thd.
4
101,6
(4.00)
3
1
Ø 25,38 (0.999)
Ø 26,95 (1.061)
Ø 28,55 (1.124)
43
PTS7-10
Pilot to shift valve
3
1
2
Description Operation
The PTS7-10 is a 2-way, This valve allows flow The spring chamber for this
2 position, pilot operated, between ports 2 and 3 until valve is externally vented to
directional screw-in sufficient pressure at port 1 atmosphere.
cartridge valve.3 overcomes the spring bias,
1 which closes both ports.
2
50
3
40 Flow - L/min (21,8 cSt oil @ 49°C)
1
300 5 10 15 20 25 30
70 5 2
20
60
4 1
Pressure Drop - bar
10
Pressure Drop - psi
20
50 56
1
10 3
40
D-84 EATON Vickers Screw-In Cartridge Valves 0
V-VLOV-MC001-E4 September, 2007 0
30 0 1 2 3 4 5 6 7 8 2
Model Code PTS7-10
1 2 3 4 5 6
D
1 Function 4 Port size 5 Pilot to shift (nominal)
PTS7 - Pilot to shift valve O - Cartridge only 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
CODE PORT SIZE HOUSING NUMBER 160 - 11,0 bar (160 psi)
2 Size Aluminum Aluminum
10 - 10 Size Light duty Fatigue rated
3B 3/8” BSPP 02-173358 – 6 Special features
6T SAE 6 566162 – 00 - None
3 Seals (Only required if valve has
2G 1/4” BSPP – 876705
Blank - Buna-N special features, omitted
3G 3/8” BSPP – 876714
V - Viton® if “00”)
6H SAE 6 – 876704
8H SAE 8 – 876711
See section J for housing details.
Dimensions
mm (inch) 25,4 (1.0) hex
19,0
Torque cartridge in (0.75)
aluminum housing
47-54 Nm (35-40 ft. lbs)
0.875" -14 Thd.
46,0 3
(1.81)
1
Ø 15,82 (0.623)
Ø 17,42 (0.686)
Description Operation
The PTS 9-8 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is vented to port
come. At that time flow is 5.
Performance
3 P Curves
5 Cartridge only
CF EF
200
44 2
LS 5 1 160
Pressure Drop - psi
PFRS-XX
3
120
3 P
2
80
A B B
2 4 S2 A
S1 1 40
SV9-8A
0
3 1 0.0 1.0 2.0 3.0 4.0 5.0
P T Flow - USgpm
A - Pressure drop port 3 to port 4
B - Pressure drop port 3 to port 2
A B
S1 2 4 S2
SV9-8B
D-86 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
3 1
P T
Model Code PTS9-8
1 2 3 4 5 6 7
D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
Port Port Aluminum Steel
2, 3 & 4 1&5
2 Size
000 No Body – – –
8 - C-8-5S Cavity
7/8" Hex
Dimensions .752
mm (inch) [19.1]
3/4" - 16 Thread
Torque cartridge in housing:
A - 34-41 Nm (25-30 ft. lbs)
S - 34-41 Nm (25-30 ft. lbs)
2.569 4
[65.25]
Aluminum hous-
1 ings can be used
.435
[11.05] • for pressures up
.497 to 210 bar (3000
[12.62] psi). Steel housings must be
.559 used for operating pressures
[14.2] above 210 bar (3000 psi).
.622
[15.8]
Description Operation
The PTS 9-10 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is vented to port
come. At that time flow is 5.
5 Performance
3 P Curves
4 Cartridge only
CF EF
34 2 300
LS 5 1
PFRS-XX
2
1
3 P 200
Psid
A B
2 4 S2
S1
100
SV9-8A Port 3 to Port 2
3 1
P T
0
0 2 4 6 8 10
A B Gpm
S1 2 4 S2
SV9-8B
D-88 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
3 1
P T
Model Code PTS9-10
1 2 3 4 5 6 7
D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
Port Port Aluminum Steel
1, 2, 3 & 4 5
2 Size 000 No Body – – –
10 - C-10-5S Cavity
1" Hex
Dimensions .813
mm (inch) [20.65]
Torque cartridge in housing: 7/8" - 14 Thread
A - 47-54 Nm (35-40 ft. lbs)
S - 68-75 Nm (50-55 ft. lbs)
5
3.069
[77.95] 4
.559 1
[14.2]
.622
[15.8] Aluminum hous-
.685
[17.4] .747 ings can be used
[18.97] • for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
Description Operation
The PTS 9-12 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is vented to port
come. At that time flow is 5.
1 2)
Pressure drop - bar
LS 5 PFRS-XX
(or
2 4
3 to
145 rt 10
Po
3 P
1
73 5
A B
2 4 S2
S1
0
SV9-8A 0 5 10 15 20
Flow - USgpm
3 1
P T
A B
S1 2 4 S2
SV9-8B
1 2 3 4 5 6 7
D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
A - Aluminum
Port Port Aluminum Steel
S - Steel 1, 2, 3 & 4 5
2 Size
000 No Body – – –
12 - C12-5S Cavity
12T SAE 12 SAE 4 4998820-002 4998821-002
06G 3/4” BSPP 1/4” BSPP 4998820-004 4998821-004
3 Seals
U - Urethane (standard) 6 Shift Pressure 7 Special features
075 psi (5,2 bar) 00 - None
* These model digits will not be stamped on the valve. 110 psi (7,6 bar) (Only required if valve has
special features, omitted
if “00”)
Dimensions
mm (inch) 1 1/4" HEX
33.3
Torque cartridge in housing (1.31)
A - 81-95 Nm (60-70 ft. lbs)
S - 102-115 Nm (75-85 ft. lbs)
1 1/16"-12 UN-2A
4
86.4
(3.40)
2
Aluminum hous-
ings can be used
1 • for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
Description Operation
The PTS 9-16 is a 3-way, This valve allows flow is directed between
2 position, pilot operated, between ports 3 and 4 ports 3 and 2 while block-
directional screw-in while blocking port 2 until ing port 4. During the
cartridge valve. sufficient pressure has cross-over transition, all
been applied to port 1 and ports are open. The spring
the spring bias is over- chamber for this valve is
come. At that time flow vented to port 5.
to
150 3 10
LS 5 1 rt
PFRS-XX Po
2
100 7
3 P
1 50 4
A B
2 4 0
S1 S2 0 5 10 15 20 25 30 35 40 45
Flow - USgpm
SV9-8A
3 1
P T
A B
S1 2 4 S2
SV9-8B
D-92 EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007
3 1
P T
Model Code PTS9-16
1 2 3 4 5 6 7
D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
A - Aluminum
Port Port Aluminum Steel
S - Steel 1, 2, 3 & 4 5
2 Size
000 No Body – – –
16 - C16-5S Cavity
16T SAE 16 SAE 4 4994880-002 4994881-002
08G 1” BSPP 1/4” BSPP 4994880-004 4994881-004
3 Seals
U - Urethane (standard) 6 Shift Pressure 7 Special features
Dimensions
mm(inch) 1.50" HEX
17.8 (.70)
Torque cartridge in housing
A - 108-122 Nm (80-90 ft. lbs)
S - 136-149Nm (100-110 ft. lbs) 1 5/16"-12 UN-2A
4
96.3 (3.79)
Aluminum hous-
2
ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
1 used for operating pressures
above 210 bar (3000 psi).
Description Operation
The PTS 9-20 is a 3-way, This valve allows flow directed between ports 3
2 position, pilot operated, between ports 3 and 4 and 2 while blocking port
directional screw-in while blocking port 2 until 4. During the cross-over
cartridge valve. sufficient pressure has transition, all ports are open.
been applied to port 1 and The spring chamber for
the spring bias is over- this valve is typically vent-
come. At that time flow is ed to port 5 (tank).
LS 5 1 300 21
1 PFRS-XX
250
Delta P psi
Delta P bar
200 14
3 P
150
A B
4
100 7
S1 2 S2
50
SV9-8A
0
0 10 20 30 40 50 60 70
3 1 Flow - GPM
P T P to EF
A B
S1 2 4 S2
SV9-8B
1 2 3 4 5 6 7
D
1 Function 4 Body 5 Ports*
PTS9 - Pilot to shift valve O - Cartridge only CODE PORT SIZE HOUSING NUMBER
A - Aluminum
Port Port Aluminum Steel
S - Steel 1, 2, 3 & 4 5
2 Size 000 No Body – – –
20 - C20-5S Cavity
16T SAE 16 SAE 4 4998822-002 4998823-002
08G 1” BSPP 1/4” BSPP 4998822-004 4998823-004
3 Seals
U - Urethane (standard) 6 Shift Pressure 7 Special features
Dimensions
mm (inch) 20,3 1 7/8" HEX
(.80)
Torque cartridge
in housing
S - 160-180Nm 1 5/8"-12 UN-2A
(120-135 ft. lbs)
A - 130-155 Nm 5
(95-115 ft. lbs)
105,2
(4.14)
3
2
Aluminum hous-
ings can be used
• for pressures up
1 to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
This section gives basic The range includes: DIfferential–pressure Flow compensators – PCS3
specifications for Vickers • Pressure compensators sensing elements – DPS2 An essential component of a
logic element and pressure For controlling pressure, pressure compensated flow
compensator threaded car- • Pressure compensators
with priority and bypass flow or direction (including control which, with an exter-
tridge valves. Its purpose is 3- and 4-way bridge cir- nal fixed or variable orifice,
to provide a quick, conven- outlets
cuits) the DPS2 is used provides the required com-
ient reference tool when • Differential–pressure with the aid of external pensated flow characteristic.
choosing these valves or sensing elements pilot operators. The DPS2 Excess flow is diverted at
designing a system using elements are function build- maximum system pressure.
The correct selection of
these components. ing blocks which respond to Excess fluid upstream must
these products can
All cartridges have hard- enhance machine perform- pressure differential signals, be diverted e.g. through a
ened and ground spools, ance, shorten the design providing the capacity to relief to tank.
and/or honed sleeves, process and minimize man- switch or modulate flows Pressure compensator with
poppets and sharp-edged ufacturing costs of manifold up to 303 L/min priority and bypass outlets
ground steel seats. This blocks. (80 USgpm) and pressure –PCS4
provides an excellent prod- to 350 bar (5000 psi).
uct that is dirt-tolerant, has Similar in function to the
The choice of pilot arrange- PCS3. The major difference
reliable seating, and is suit- ments related to DPS2
able for fast cycling with is that excess flow is divert-
variants can minimize the ed at priority flow pressure,
long life. number of construction instead of at maximum sys-
These Vickers cartridges holes in a manifold, tem pressure, as is the
provide the system design- simplifying design and case with PCS3 compen-
er with a versatile range of reducing costs. sators. The excess flow can
elements for use in MCD All poppet type DPS2 pass to a secondary circuit
packages for controlling elements have recently or to tank.
pressure, flow and direction been upgraded to 350 bar
of flow. (5000 psi).
I
Pressure control
functions Fixed
restrictor
Pressure relief or Pilot pressure
Sequence example source
With external pilot supply and pilot relief
Pilot relief
3 valve
1 2
DPS2-**-P differential
pressure sensing
cartridge
Uni-directional flow
Pressure relief or
Sequence example
With internal pilot supply and pilot relief
Pilot relief
3
valve
1 2
DPS2-**-V dif ferential
pressure sensing
cartridge
Uni-directional flow
Pilot relief
valve
Pressure reducing example
Non-relieving type
3
2 1
DPS2-**-R differential
pressure sensing
cartridge
Uni-directional flow
Reduced pressure
sub-circuit
DPS2-**-R
differential DPS2-**-V
pressure differential
sensing pressure
1 cartridge sensing
cartridge Pilot
Relief
DPS2-**-V differential 3 Valve
pressure sensing
cartridge
PUV3-10
2
Full pressure
sub-circuit
2 1
DPS2-**-V
1 differential
pressure sensing
DPS2-**-S differential cartridge
pressure sensing
cartridge 3 2 3
Pilot Pilot
Sequence Sequence
Valve Valve
Pressure compensated
flow control example
With downstream fixed
or variable restrictor
2 1
DPS2-**-F differential Fixed or
pressure sensing variable
cartridge restrictor
Uni-directional flow
Pressure compensated
priority flow control
example
Fixed or variable priority
With fixed or variable flow restrictor
priority flow control Inlet Priority flow outlet
3
1
DPS2-**-P differential 2
pressure sensing
cartridge
Uni-directional flow
1
Fixed
pilot restrictor
DPS2-**-P differential
pressure sensing
cartridge Venting
pilot
2 3
directional
valve
Pressure limiter
pilot relief valve
Fixed
pilot restrictor
Pilot
relief
valve
DPS2-**-FF
Hydrostat Dampening orifice
compensator typ. 0.30 to 0.060
Relief valve 80
DPS2-**-FF
pressure limiting psi DPS2-**-FF
Hydrostat 80 Hydrostat
compensator psi compensator
DPS2-**-PF
Relief valve 80 Load sense
pressure limiting psi unloading
DPS2-**-FF
80
160 elelment
Hydrostat
psi
psi compensator
DPS2-**-PF
Load sense
unloading
Load sense bleedelelment
160
Main relief psi
typ. 0.10 GPM
Two-way, two-position,
normally open examples
Switched by 3-way, 2-position pilot valve Switched by external pilot pressure and vented
and external pilot pressure through 2-way , 2-position pilot valve
Pilot pressure Fixed
restrictor
source
Pilot
pressure
Pilot source
3 3 Pilot
directional directional
1 2 valve 1 2 valve
DPS2-**-P differential DPS2-**-P differential
pressure sensing cartridge pressure sensing cartridge
Uni-directional flow Uni-directional flow
With DPS2-**-V cartridge and internal pilot supply With DPS2-**-B cartridge and internal pilot supply
& vented through 2-way,2 position pilot valve & vented through 2-way,2 position pilot valve
Uni-directional flow
Uni-directional flow
With DPS2-**-S cartridge and internal pilot supply With DPS2-**-T cartridge and internal pilot supply
& vented through 2-way, 2 position pilot valve & swithed by 3-way, 2 position pilot valve and
external pilot pressure
Bi-directional flow
Uni-directional flow
With DPS2-**-T cartridge and internal With DPS2-**-T cartridge, external pilot supply
shuttle-selected pilot supply and two-way two-position pilot valve
Pilot directional valve Fixed restrictor
DPS2-**-T differential Pilot
pressure sensing cartridge source
Pilot
DPS2-**-T differential directional
3
pressure valve
2 Pilot sensing
1 shuttle cartridge 3
valve
2
1 Bi-directional flow
Bi-directional flow
B A B A B
P1 P4 P1 P4
P T
A
A B
B
A B P5 A
A B
B
A
A C B B A B
A C B A
A B
B
ADPS2-**-T
With C
C B A C
C B With DPS2-**-P P T
C C
C
C
Poppet type C Spool type P5
C C
A
A B
B A
A PRESSURE
B B
REQUIRED
A B PILOT
A A
A B
B TO A B
REQUIRED PILOT PRESSURE TO
A
A
FLOW B
P PATH
T
B P1 A AB
PP2 A BT P4B
B A
A B
B
P
P T T A
P P PP3
BT T P5
A B
FLOW
AA
P PATH
T
B P1 P2 P3 P4 P5
A
P
A
B
T
B A
AP
P
P1B
A BT
T T
T 1 P
P BT
T
P T 1 P1 P
P T 1BT
T
A
P
P
BT
T 1 1 0 1 1
P T P T
P T P PT T P T
0 0 0 0 0 0 1 1 1 1
1 1 0 0 0 0 1 0 1 1
0 0 1 1 0 1 0 1 0 1
1 1 1 1 0 1 1 1 0 1
1 0 0 1 1 1 0 1 1 1
I
0 1 1 0 1
Note
Pilot pressure, modified by
valve area ratio (if any),
must exceed load pressure
at valve in order to close
valve.
Description Operation
The DPS2-10 is a This valve is used as a either directional control,
differential pressure main section of a pilot flow control or pressure
sensing valve, available controlled valve assembly. control cartridges. Refer to
as either a spool or This valve has multiple application examples.
poppet type and with uses when used with
either, internal or external
pilot.
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (spool type) 290 bar (4200 psi)
(poppet type) 350 bar (5000 psi)**
Rated flow 60 L/min (15 USgpm)
Functional Symbols
Pilot ratio (spool type P,V,R,F) 1:1
See pages I-20 & I-21 (poppet type B,S,T) 2:1
Internal leakage, poppet type Port 1 to 2: < 5 drops/min max @ 350 bar (5000 psi)
Internal leakage, spool type 82 cm 3/min. (5 in 3/min) max @ 290 bar (4200 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-10-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 14 kg (0.30 lbs)
Profile View Seal kits 889650 Buna-N
889652 Viton®
Viton is a registered trademark of E.I. DuPont
200 14
3
Pressure drop - bar
Pressure drop - psi
12
150 10
8
2 100
6
50 4
1
2
0 0
0 2 4 6 8 10 12 1 6
Flow - USgpm (105 SUS oil @ 120° F)
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
I
Torque cartridge
in housing
A – 47-54 Nm (35-40 ft. lbs)
S – 68-70 Nm (50-55 ft. lbs)
Aluminum hous-
ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
Description Operation
The DPS2-12 is a This valve is used as a either directional control,
differential pressure main section of a pilot flow control or pressure
sensing valve, available controlled valve assembly. control cartridges. Refer to
as a spool type with either, This valve has multiple application examples.
internal or external pilot. uses when used with
200 13.8
Pressure drop 1 to 2 in bar
Pressure Drop 1 to 2 in psi
150 10.3
3
100 6.8
2
50 3.4
1 0 0
0 5 10 15 20 25 30
Flow (GPM)
1 2 3 4 5 6 7 8
Dimensions
mm (inch)
Torque cartridge
in housing
A – 81-95 Nm (60-70 ft. lbs)
S – 102-115 Nm (75-85 ft. lbs) 1.063 - 12 Thd.
38,2 (2.29)
Aluminum hous-
ings can be used
• for pressures up
to 210 bar (3000
psi). Steel housings must be
22,2 (0.873) used for operating pressures
above 210 bar (3000 psi).
23,7 (0.935)
Description Operation
The DPS2-16 is a This valve is used as a main This valve has multiple flow control or pressure
differential pressure section of a pilot controlled uses when used with control cartridges. Refer to
sensing valve, available valve assembly. either directional control, application examples.
as either a spool or
poppet type and with RATINGS AND SPECIFICATIONS
either, internal or external Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
pilot. Typical application pressure (spool type) 290 bar (4200 psi)
(poppet type) 210 bar (3000 psi) or 350 bar (5000 psi)**
Rated flow 189 L/min (50 USgpm)
Pilot ratio (spool type P,V,R,F) 1:1
(poppet type B,S,T) 2:1
Functional Symbols Internal leakage, poppet type Port 1 to 2: < 5 drops/min. max @ 350 bar (5000 psi)
See pages I-20 & I-21 Internal leakage, spool type 82 cm 3/min. (5 in 3/min) max @ 290 bar (4200 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-16-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 35 kg (0.78 lbs)
Seal kits 889659 Buna-N
02-165871 Viton®
Viton is a registered trademark of E.I. DuPont
Profile View
200 14
Pressure drop - bar
Pressure drop - psi
3
12
150 10
8
100
2 6
4
50
1 2
0
0 10 20 30 40 50
Flow - USgpm (105 SUS oil @ 120° F)
1 2 3 4 5 6 7 8
55,6
(2.18)
Aluminum hous-
2 ings can be used
• for pressures up
to 210 bar (3000
1 psi). Steel housings must be
25,37 (0.999)
used for operating pressures
28,50 (1.122) above 210 bar (3000 psi).
Description Operation
The DPS2-20 is a This valve is used as a This valve has multiple flow control or pressure
differential pressure main section of a pilot uses when used with control cartridges. Refer to
sensing valve, available controlled valve assembly. either directional control, application examples.
as either a spool or
poppet type and with RATINGS AND SPECIFICATIONS
either, internal or external Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
pilot. Typical application pressure (spool type) 290 bar (4200 psi)
(poppet type) 210 bar (3000 psi) or 350 bar (5000 psi)**
Rated flow 303 L/min (80 USgpm)
Pilot ratio (spool type P,V,R,F) 1:1
(poppet type B,S,T) 2:1
Functional Symbols Internal leakage, poppet type Port 1 to 2: < 5 drops/min max @ 350 bar (5000 psi)
See pages I-20 & I-21 Internal leakage, spool type 82 cm 3/min (5 in 3/min) max @ 290 bar (4200 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-20-3S
Standard housing materials Aluminum
Fluids All general purpose hydraulic fluids such as:
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0, 81 kg (1.78 lbs)
Seal kits 02-113153 Buna-N
02-112969 Viton®
Viton is a registered trademark of E.I. DuPont
Profile View
3 12
150
10
8
100
2 6
50 4
1 2
0 0
0 10 20 30 40 50 60 70 80
Flow - USgpm (105 SUS oil @ 120° F)
1 2 3 4 5 6 7 8
2 3 2 3 2 3 2 3
DPS2-**-F-F DPS2-**-R-F
2 2 3
1 3 1
2 3 2 3 1 3 1 3
DPS2-**-T-S DPS2-**-T-F
1 1 I
2 3 2 3