Vous êtes sur la page 1sur 30

Diagnostic Troubleshoot Code BRK

Description
Codes SIS Links
[Data Link] SPN, CID, or PID - FMI
- External Tank High Fuel
Level Shutdown
[J1939/ATA] Second Fuel Level
- Digital Input Circuit Fault
38-00 - Analog Input Circuit Fault
- Data Valid but above Normal
- 4490 - ELECTRONIC
Operating Range (most severe)
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- External Tank Low Fuel Level
Shutdown
- Digital Input Circuit Fault
38-01 [J1939/ATA] Second Fuel Level - Analog Input Circuit Fault
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- External Tank Fuel Level
Sensor Short High
- Analog Input Circuit Fault
38-03 [J1939/ATA] Second Fuel Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- External Tank Fuel Level
Sensor Short Low
- Analog Input Circuit Fault
38-04 [J1939/ATA] Second Fuel Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- External Tank High Fuel
Level Warning
[J1939/ATA] Second Fuel Level
- Digital Input Circuit Fault
38-15 - Analog Input Circuit Fault
- Data Valid but above Normal
- 4490 - ELECTRONIC
Operating Range (least severe)
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- External Tank Low Fuel Level
Warning
[J1939/ATA] Second Fuel Level
- Digital Input Circuit Fault
38-17 - Analog Input Circuit Fault
- Data Valid But Below Normal
- 4490 - ELECTRONIC
Operating Range (least severe)
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Air Start Pressure
- High Starting Air Pressure
Shutdown
[CDL] Air Start Pressure Sensor
- Digital Input Circuit Fault
82-00 - Analog Input Circuit Fault
[ATA] Cylinder #3 Compression Brake
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Low Starting Air Pressure
[J1939] Engine Air Start Pressure Shutdown
- Digital Input Circuit Fault
82-01 [CDL] Air Start Pressure Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Cylinder #3 Compression Brake MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Starting Air Pressure Sensor
[J1939] Engine Air Start Pressure
Short High
- Analog Input Circuit Fault
82-03 [CDL] Air Start Pressure Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Cylinder #3 Compression Brake
- 7566 - WIRING DIAGRAM
- Starting Air Pressure Sensor
[J1939] Engine Air Start Pressure
Short Low
- Analog Input Circuit Fault
82-04 [CDL] Air Start Pressure Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Cylinder #3 Compression Brake
- 7566 - WIRING DIAGRAM
[J1939] Engine Air Start Pressure
- High Starting Air Pressure
Warning
[CDL] Air Start Pressure Sensor
- Digital Input Circuit Fault
82-15 - Analog Input Circuit Fault
[ATA] Cylinder #3 Compression Brake
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Air Start Pressure
- Low Starting Air Pressure
Warning
[CDL] Air Start Pressure Sensor
- Digital Input Circuit Fault
82-17 - Analog Input Circuit Fault
[ATA] Cylinder #3 Compression Brake
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Fuel Filter Differential
Pressure
- High Fuel Filter Differential
Pressure Shutdown
[CDL] Fuel Filter Differential Pressure
- Digital Input Circuit Fault
Sensor
95-00 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Fuel Filter Restriction
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (most severe)
[J1939] Engine Fuel Filter Differential - Low Fuel Filter Differential
Pressure Pressure Shutdown
- Digital Input Circuit Fault
95-01 [CDL] Fuel Filter Differential Pressure - Analog Input Circuit Fault
Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Fuel Filter Restriction - 7566 - WIRING DIAGRAM
[J1939] Engine Fuel Filter Differential - Fuel Filter Differential
Pressure Pressure Sensor Short High
95-03 - Analog Input Circuit Fault
[CDL] Fuel Filter Differential Pressure - 4490 - ELECTRONIC
Sensor MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[ATA] Fuel Filter Restriction
[J1939] Engine Fuel Filter Differential
- Fuel Filter Differential
Pressure
Pressure Sensor Short Low
- Analog Input Circuit Fault
95-04 [CDL] Fuel Filter Differential Pressure
- 4490 - ELECTRONIC
Sensor
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[ATA] Fuel Filter Restriction
[J1939] Engine Fuel Filter Differential
Pressure
- High Fuel Filter Differential
Pressure Warning
[CDL] Fuel Filter Differential Pressure
- Digital Input Circuit Fault
Sensor
95-15 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Fuel Filter Restriction
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] Engine Fuel Filter Differential
Pressure
- Low Fuel Filter Differential
Pressure Warning
[CDL] Fuel Filter Differential Pressure
- Digital Input Circuit Fault
Sensor
95-17 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Fuel Filter Restriction
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid But Below Normal
Operating Range (least severe)
[J1939] Fuel Level
- High Fuel Level Shutdown
[CDL] Fuel Level Sensor - Digital Input Circuit Fault
- Analog Input Circuit Fault
96-00
[ATA] Fuel Level - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Low Fuel Level Shutdown
[J1939] Fuel Level
- Digital Input Circuit Fault
- Analog Input Circuit Fault
96-01 [CDL] Fuel Level Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Fuel Level
- 7566 - WIRING DIAGRAM
[J1939] Fuel Level - Fuel Level Sensor Short High
- Analog Input Circuit Fault
96-03 [CDL] Fuel Level Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Fuel Level - 7566 - WIRING DIAGRAM
[J1939] Fuel Level - Fuel Level Sensor Short Low
- Analog Input Circuit Fault
96-04 [CDL] Fuel Level Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Fuel Level - 7566 - WIRING DIAGRAM
[J1939] Fuel Level - High Fuel Level Warning
96-15 - Digital Input Circuit Fault
[CDL] Fuel Level Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Fuel Level MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] Fuel Level
- Low Fuel Level Warning
[CDL] Fuel Level Sensor - Digital Input Circuit Fault
- Analog Input Circuit Fault
96-17
[ATA] Fuel Level - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Oil Level
- High Engine Oil Level
Shutdown
[CDL] Engine Oil Level Sensor
- Digital Input Circuit Fault
98-00 - Analog Input Circuit Fault
[ATA] Engine Oil Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Low Engine Oil Level
[J1939] Engine Oil Level Shutdown
- Digital Input Circuit Fault
98-01 [CDL] Engine Oil Level Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Engine Oil Level MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Engine Oil Level Sensor
[J1939] Engine Oil Level
Short High
- Analog Input Circuit Fault
98-03 [CDL] Engine Oil Level Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Engine Oil Level
- 7566 - WIRING DIAGRAM
- Engine Oil Level Sensor
[J1939] Engine Oil Level
Short Low
- Analog Input Circuit Fault
98-04 [CDL] Engine Oil Level Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Engine Oil Level
- 7566 - WIRING DIAGRAM
[J1939] Engine Oil Level
- High Engine Oil Level
Warning
[CDL] Engine Oil Level Sensor
- Digital Input Circuit Fault
98-15 - Analog Input Circuit Fault
[ATA] Engine Oil Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Oil Level
- Low Engine Oil Level
Warning
[CDL] Engine Oil Level Sensor
- Digital Input Circuit Fault
98-17 - Analog Input Circuit Fault
[ATA] Engine Oil Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Oil Filter Differential
Pressure
- High Oil Filter Differential
Pressure Shutdown
[CDL] Engine Oil Filter Differential
- Digital Input Circuit Fault
Pressure Sensor
99-00 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Engine Oil Filter Restriction
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (most severe)
[J1939] Engine Oil Filter Differential - Low Oil Filter Differential
Pressure Pressure Shutdown
- Digital Input Circuit Fault
99-01 [CDL] Engine Oil Filter Differential - Analog Input Circuit Fault
Pressure Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Engine Oil Filter Restriction - 7566 - WIRING DIAGRAM
[J1939] Engine Oil Filter Differential
- Oil Filter Differential Pressure
Pressure
Sensor Short High
- Analog Input Circuit Fault
99-03 [CDL] Engine Oil Filter Differential
- 4490 - ELECTRONIC
Pressure Sensor
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[ATA] Engine Oil Filter Restriction
[J1939] Engine Oil Filter Differential
- Oil Filter Differential Pressure
Pressure
Sensor Short Low
- Analog Input Circuit Fault
99-04 [CDL] Engine Oil Filter Differential
- 4490 - ELECTRONIC
Pressure Sensor
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[ATA] Engine Oil Filter Restriction
[J1939] Engine Oil Filter Differential
Pressure
- High Oil Filter Differential
Pressure Warning
[CDL] Engine Oil Filter Differential
- Digital Input Circuit Fault
Pressure Sensor
99-15 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Engine Oil Filter Restriction
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] Engine Oil Filter Differential
Pressure
- Low Oil Filter Differential
Pressure Warning
[CDL] Engine Oil Filter Differential
- Digital Input Circuit Fault
Pressure Sensor
99-17 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Engine Oil Filter Restriction
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid But Below Normal
Operating Range (least severe)
- Low Engine Oil Pressure
[J1939] Engine Oil Pressure
Shutdown
- Data Link Circuit Fault
100-01 [CDL] Engine Oil Pressure Sensor
- Digital Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Oil Pressure
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Oil Pressure
- Engine Oil Pressure Sensor
100-03 [CDL] Engine Oil Pressure Sensor
Short High
[ATA] Oil Pressure
[J1939] Engine Oil Pressure
- Engine Oil Pressure Sensor
100-04 [CDL] Engine Oil Pressure Sensor
Short Low
[ATA] Oil Pressure
[J1939] Engine Oil Pressure
- Low Engine Oil Pressure
Warning
[CDL] Engine Oil Pressure Sensor
- Data Link Circuit Fault
100-17 - Digital Input Circuit Fault
[ATA] Oil Pressure
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
- High Air Filter Differential
[J1939] Engine Air Filter 1 Differential Pressure Shutdown
Pressure - Digital Input Circuit Fault
107-00 - Analog Input Circuit Fault
- Data Valid but above Normal - 4490 - ELECTRONIC
Operating Range (most severe) MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Low Air Filter Differential
Pressure Shutdown
- Digital Input Circuit Fault
[J1939] Engine Air Filter 1 Differential
107-01 - Analog Input Circuit Fault
Pressure
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Air Filter Differential Pressure
Sensor Short High
[J1939] Engine Air Filter 1 Differential - Analog Input Circuit Fault
107-03
Pressure - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Air Filter Differential Pressure
Sensor Short Low
[J1939] Engine Air Filter 1 Differential - Analog Input Circuit Fault
107-04
Pressure - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- High Air Filter Differential
[J1939] Engine Air Filter 1 Differential Pressure Warning
Pressure - Digital Input Circuit Fault
107-15 - Analog Input Circuit Fault
- Data Valid but above Normal - 4490 - ELECTRONIC
Operating Range (least severe) MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Air Filter 1 Differential - Low Air Filter Differential
Pressure Pressure Warning
107-17
- Digital Input Circuit Fault
- Data Valid But Below Normal - Analog Input Circuit Fault
Operating Range (least severe) - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Coolant Temperature
- High Engine Coolant
[CDL] Engine Coolant Temperature Temperature Shutdown
Sensor - Data Link Circuit Fault
110-00 - Digital Input Circuit Fault
[ATA] Coolant Temperature - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
[J1939] Engine Coolant Temperature

[CDL] Engine Coolant Temperature - Engine Coolant Temperature


110-03
Sensor Sensor Short High

[ATA] Coolant Temperature


[J1939] Engine Coolant Temperature

[CDL] Engine Coolant Temperature - Engine Coolant Temperature


110-04
Sensor Sensor Short Low

[ATA] Coolant Temperature


[J1939] Engine Coolant Temperature
- High Engine Coolant
[CDL] Engine Coolant Temperature Temperature Warning
Sensor - Data Link Circuit Fault
110-15 - Digital Input Circuit Fault
[ATA] Coolant Temperature - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Coolant Temperature
- Low Engine Coolant
[CDL] Engine Coolant Temperature Temperature Warning
Sensor - Data Link Circuit Fault
110-17 - Digital Input Circuit Fault
[ATA] Coolant Temperature - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Coolant Level
- High Engine Coolant Level
Shutdown
[CDL] Engine Coolant Level Sensor
- Digital Input Circuit Fault
111-00 - Analog Input Circuit Fault
[ATA] Coolant Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Low Engine Coolant Level
[J1939] Engine Coolant Level Shutdown
- Digital Input Circuit Fault
111-01 [CDL] Engine Coolant Level Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Coolant Level MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Engine Coolant Level Sensor
[J1939] Engine Coolant Level
Short High
- Analog Input Circuit Fault
111-03 [CDL] Engine Coolant Level Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Coolant Level
- 7566 - WIRING DIAGRAM
- Engine Coolant Level Sensor
[J1939] Engine Coolant Level
Short Low
- Analog Input Circuit Fault
111-04 [CDL] Engine Coolant Level Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Coolant Level
- 7566 - WIRING DIAGRAM
[J1939] Engine Coolant Level
- High Engine Coolant Level
Warning
[CDL] Engine Coolant Level Sensor
- Digital Input Circuit Fault
111-15 - Analog Input Circuit Fault
[ATA] Coolant Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Coolant Level
- Low Engine Coolant Level
Warning
[CDL] Engine Coolant Level Sensor
- Digital Input Circuit Fault
111-17 - Analog Input Circuit Fault
[ATA] Coolant Level
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary Gage Pressure
Reading 1
- High Fire Extinguisher
Pressure Shutdown
[CDL] Left Motor Pilot Pressure Sensor
- Digital Input Circuit Fault
137-00 - Analog Input Circuit Fault
[ATA] Intake Valve Actuation System Oil
- 4490 - ELECTRONIC
Pressure Solenoid
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (most severe)
[J1939] Auxiliary Gage Pressure - Low Fire Extinguisher
Reading 1 Pressure Shutdown
- Digital Input Circuit Fault
137-01 [CDL] Left Motor Pilot Pressure Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Intake Valve Actuation System Oil MODULAR CONTROL PANEL
Pressure Solenoid - 7566 - WIRING DIAGRAM
[J1939] Auxiliary Gage Pressure
- Fire Extinguisher Pressure
Reading 1
Sensor Short High
- Analog Input Circuit Fault
137-03 [CDL] Left Motor Pilot Pressure Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Intake Valve Actuation System Oil
- 7566 - WIRING DIAGRAM
Pressure Solenoid
[J1939] Auxiliary Gage Pressure - Fire Extinguisher Pressure
Reading 1 Sensor Short Low
137-04 - Analog Input Circuit Fault
[CDL] Left Motor Pilot Pressure Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Intake Valve Actuation System Oil - 7566 - WIRING DIAGRAM
Pressure Solenoid
[J1939] Auxiliary Gage Pressure
Reading 1
- High Fire Extinguisher
Pressure Warning
[CDL] Left Motor Pilot Pressure Sensor
- Digital Input Circuit Fault
137-15 - Analog Input Circuit Fault
[ATA] Intake Valve Actuation System Oil
- 4490 - ELECTRONIC
Pressure Solenoid
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] Auxiliary Gage Pressure
Reading 1
- Low Fire Extinguisher
Pressure Warning
[CDL] Left Motor Pilot Pressure Sensor
- Digital Input Circuit Fault
137-17 - Analog Input Circuit Fault
[ATA] Intake Valve Actuation System Oil
- 4490 - ELECTRONIC
Pressure Solenoid
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid But Below Normal
Operating Range (least severe)
[J1939] Charging System Potential
- Low Battery Charging
System Voltage Warning
[CDL] Alternator Charging Voltage
- Charging System
167-17 Sensor
- 1401 - BATTERY
- 1405 - ALTERNATOR
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Battery Potential
- High Battery Voltage
[CDL] Electrical System Voltage Shutdown
- Charging System
168-00
[ATA] ECM Battery Power - 1401 - BATTERY
- 1405 - ALTERNATOR
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
[J1939] Battery Potential
- High Battery Voltage Warning
[CDL] Electrical System Voltage
- Charging System
168-15 - 1401 - BATTERY
[ATA] ECM Battery Power
- 1405 - ALTERNATOR
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] Battery Potential
- Low Battery Voltage Warning
[CDL] Electrical System Voltage
- Charging System
168-17 - 1401 - BATTERY
[ATA] ECM Battery Power
- 1405 - ALTERNATOR
- 7566 - WIRING DIAGRAM
- Data Valid But Below Normal
Operating Range (least severe)
[J1939] Ambient Air Temperature - High Ambient Air
Temperature Shutdown
171-00
[CDL] Ambient Air Temperature Sensor - Digital Input Circuit Fault
- Analog Input Circuit Fault
[ATA] Loss of Ambient Air Temperature - 4490 - ELECTRONIC
Data MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (most severe)
- Low Ambient Air
[J1939] Ambient Air Temperature
Temperature Shutdown
- Digital Input Circuit Fault
[CDL] Ambient Air Temperature Sensor
171-01 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Loss of Ambient Air Temperature
MODULAR CONTROL PANEL
Data
- 7566 - WIRING DIAGRAM
[J1939] Ambient Air Temperature - Ambient Air Temperature
Sensor Short High
[CDL] Ambient Air Temperature Sensor - Analog Input Circuit Fault
171-03
- 4490 - ELECTRONIC
[ATA] Loss of Ambient Air Temperature MODULAR CONTROL PANEL
Data - 7566 - WIRING DIAGRAM
[J1939] Ambient Air Temperature - Ambient Air Temperature
Sensor Short Low
[CDL] Ambient Air Temperature Sensor - Analog Input Circuit Fault
171-04
- 4490 - ELECTRONIC
[ATA] Loss of Ambient Air Temperature MODULAR CONTROL PANEL
Data - 7566 - WIRING DIAGRAM
[J1939] Ambient Air Temperature
- High Ambient Air
[CDL] Ambient Air Temperature Sensor Temperature Warning
- Digital Input Circuit Fault
171-15 [ATA] Loss of Ambient Air Temperature - Analog Input Circuit Fault
Data - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Ambient Air Temperature
- Low Ambient Air
[CDL] Ambient Air Temperature Sensor Temperature Warning
- Digital Input Circuit Fault
171-17 [ATA] Loss of Ambient Air Temperature - Analog Input Circuit Fault
Data - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Exhaust Gas - High Exhaust Temperature
Temperature Shutdown
- Digital Input Circuit Fault
173-00 [ATA] Exhaust Gas Temperature - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
- Low Exhaust Temperature
Shutdown
[J1939] Engine Exhaust Gas
- Digital Input Circuit Fault
Temperature
173-01 - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Exhaust Gas Temperature
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Exhaust Temperature Sensor
[J1939] Engine Exhaust Gas Short High
Temperature - Analog Input Circuit Fault
173-03
- 4490 - ELECTRONIC
[ATA] Exhaust Gas Temperature MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Exhaust Temperature Sensor
[J1939] Engine Exhaust Gas Short Low
Temperature - Analog Input Circuit Fault
173-04
- 4490 - ELECTRONIC
[ATA] Exhaust Gas Temperature MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Gas
Temperature - Exhaust Temperature Signal
173-08
Abnormal
[ATA] Exhaust Gas Temperature
[J1939] Engine Exhaust Gas - High Exhaust Temperature
Temperature Warning
- Digital Input Circuit Fault
173-15 [ATA] Exhaust Gas Temperature - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Gas - Low Exhaust Temperature
Temperature Warning
- Digital Input Circuit Fault
173-17 [ATA] Exhaust Gas Temperature - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Engine Oil Temperature 1
- High Engine Oil Temperature
Shutdown
[CDL] Engine Oil Temperature Sensor
- Digital Input Circuit Fault
175-00 - Analog Input Circuit Fault
[ATA] Engine Oil Temperature
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Low Engine Oil Temperature
[J1939] Engine Oil Temperature 1 Shutdown
- Digital Input Circuit Fault
175-01 [CDL] Engine Oil Temperature Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Engine Oil Temperature MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Engine Oil Temperature
[J1939] Engine Oil Temperature 1
Sensor Short High
- Analog Input Circuit Fault
175-03 [CDL] Engine Oil Temperature Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Engine Oil Temperature
- 7566 - WIRING DIAGRAM
[J1939] Engine Oil Temperature 1 - Engine Oil Temperature
Sensor Short Low
175-04 [CDL] Engine Oil Temperature Sensor - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[ATA] Engine Oil Temperature MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Oil Temperature 1
- High Engine Oil Temperature
Warning
[CDL] Engine Oil Temperature Sensor
- Digital Input Circuit Fault
175-15 - Analog Input Circuit Fault
[ATA] Engine Oil Temperature
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Oil Temperature 1
- Low Engine Oil Temperature
Warning
[CDL] Engine Oil Temperature Sensor
- Digital Input Circuit Fault
175-17 - Analog Input Circuit Fault
[ATA] Engine Oil Temperature
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Speed
- Engine Over Speed
[CDL] Engine Speed Sensor Shutdown
- Engine Overspeed Warning
190-00
[ATA] Primary Engine Speed - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Engine Under Speed
[J1939] Engine Speed
Shutdown
- Engine Underspeed Warning
190-01 [CDL] Engine Speed Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Primary Engine Speed
- 7566 - WIRING DIAGRAM
- Engine Speed Sensor Erratic
[J1939] Engine Speed
or Not Present
- Engine Speed Circuit Fault
190-02 [CDL] Engine Speed Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Primary Engine Speed
- 7566 - WIRING DIAGRAM
[J1939] Engine Speed - Engine Speed Sensor Open
- Engine Speed Circuit Fault
190-05 [CDL] Engine Speed Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[ATA] Primary Engine Speed - 7566 - WIRING DIAGRAM
[J1939] Engine Speed
- Engine Under Speed
[CDL] Engine Speed Sensor Warning
- Engine Underspeed Warning
190-17
[ATA] Primary Engine Speed - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Software Identification
234-31 - Software Version Mismatch
- Not Available Or Condition Exists
[J1939] Proprietary Data Link - SCADA Data Link Fault
625-11 - Data Link Circuit Fault
- Failure Mode Not Identifiable - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Primary Data Link Fault
[J1939] J1939 Network #1 - Data Link Circuit Fault
639-11 - 4490 - ELECTRONIC
- Failure Mode Not Identifiable MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I
- Custom Event #1 High
Shutdown
[CDL] Transmission Output Speed
- Digital Input Circuit Fault
701-00 Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Custom Event #1 Low
[J1939] Auxiliary I Shutdown
- Digital Input Circuit Fault
701-01
[CDL] Transmission Output Speed - 4490 - ELECTRONIC
Sensor MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I
- Custom Event #1 High
Warning
[CDL] Transmission Output Speed
- Digital Input Circuit Fault
701-15 Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #1 Low
Warning
[CDL] Transmission Output Speed
- Digital Input Circuit Fault
701-17 Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #1 Status
- Digital Input Circuit Fault
[CDL] Transmission Output Speed
701-31 - 4490 - ELECTRONIC
Sensor
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #2 High
Shutdown
[CDL] Transmission Gear Lever
- Digital Input Circuit Fault
702-00 Selector Sensor (Switch)
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Custom Event #2 Low
[J1939] Auxiliary I Shutdown
- Digital Input Circuit Fault
702-01
[CDL] Transmission Gear Lever - 4490 - ELECTRONIC
Selector Sensor (Switch) MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #2 High
702-15 Warning
[CDL] Transmission Gear Lever - Digital Input Circuit Fault
Selector Sensor (Switch) - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #2 Low
Warning
[CDL] Transmission Gear Lever
- Digital Input Circuit Fault
702-17 Selector Sensor (Switch)
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #2 Status
- Digital Input Circuit Fault
[CDL] Transmission Gear Lever
702-31 - 4490 - ELECTRONIC
Selector Sensor (Switch)
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I - Custom Event #3 High
Shutdown
[CDL] Trailer Door Position Sensor - Digital Input Circuit Fault
703-00
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
- Custom Event #3 Low
Shutdown
[J1939] Auxiliary I
- Digital Input Circuit Fault
703-01
- 4490 - ELECTRONIC
[CDL] Trailer Door Position Sensor
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #3 High
Warning
[CDL] Trailer Door Position Sensor - Digital Input Circuit Fault
703-15
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #3 Low
Warning
[CDL] Trailer Door Position Sensor - Digital Input Circuit Fault
703-17
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #3 Status
- Digital Input Circuit Fault
703-31 [CDL] Trailer Door Position Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #4 High
Shutdown
[CDL] Service Brake Pressure Switch - Digital Input Circuit Fault
704-00
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
- Custom Event #4 Low
[J1939] Auxiliary I
Shutdown
704-01
- Digital Input Circuit Fault
[CDL] Service Brake Pressure Switch
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #4 High
Warning
[CDL] Service Brake Pressure Switch - Digital Input Circuit Fault
704-15
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #4 Low
Warning
[CDL] Service Brake Pressure Switch - Digital Input Circuit Fault
704-17
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #4 Status
- Digital Input Circuit Fault
704-31 [CDL] Service Brake Pressure Switch - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #5 High
Shutdown
[CDL] Body Raise Sensor (Switch) - Digital Input Circuit Fault
705-00
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
- Custom Event #5 Low
Shutdown
[J1939] Auxiliary I
- Digital Input Circuit Fault
705-01
- 4490 - ELECTRONIC
[CDL] Body Raise Sensor (Switch)
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #5 High
Warning
[CDL] Body Raise Sensor (Switch) - Digital Input Circuit Fault
705-15
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #5 Low
Warning
[CDL] Body Raise Sensor (Switch) - Digital Input Circuit Fault
705-17
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #5 Status
- Digital Input Circuit Fault
705-31 [CDL] Body Raise Sensor (Switch) - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #6 High
Shutdown
[CDL] Body Up Sensor - Digital Input Circuit Fault
706-00
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
706-01 [J1939] Auxiliary I - Custom Event #6 Low
Shutdown
[CDL] Body Up Sensor - Digital Input Circuit Fault
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #6 High
Warning
[CDL] Body Up Sensor - Digital Input Circuit Fault
706-15
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #6 Low
Warning
[CDL] Body Up Sensor - Digital Input Circuit Fault
706-17
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #6 Status
- Digital Input Circuit Fault
706-31 [CDL] Body Up Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists - 7566 - WIRING DIAGRAM
[J1939] Auxiliary I
- Custom Event #7 High
[CDL] Transmission Gear Actuator Up Shutdown
707-00 Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Custom Event #7 Low
[J1939] Auxiliary I
Shutdown
707-01 - 7569 -TROUBLESHOOTING
[CDL] Transmission Gear Actuator Up
PROCEDURE
Solenoid
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I
- Custom Event #7 High
[CDL] Transmission Gear Actuator Up Warning
707-15 Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #7 Low
[CDL] Transmission Gear Actuator Up Warning
707-17 Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid But Below Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #7 Status
[CDL] Transmission Gear Actuator Up - 7569 -TROUBLESHOOTING
707-31
Solenoid PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I - Custom Event #8 High
708-00
Shutdown
[CDL] Transmission Gear Actuator - 7569 -TROUBLESHOOTING
Down Solenoid PROCEDURE
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (most severe)
- Custom Event #8 Low
[J1939] Auxiliary I
Shutdown
708-01 - 7569 -TROUBLESHOOTING
[CDL] Transmission Gear Actuator
PROCEDURE
Down Solenoid
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I
- Custom Event #8 High
[CDL] Transmission Gear Actuator Warning
708-15 Down Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #8 Low
[CDL] Transmission Gear Actuator Warning
708-17 Down Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid But Below Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Auxiliary I
- Custom Event #8 Status
[CDL] Transmission Gear Actuator - 7569 -TROUBLESHOOTING
708-31
Down Solenoid PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #9 Status
[CDL] Transmission Lockup Clutch - 7569 -TROUBLESHOOTING
709-31
Solenoid PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #10 Status
- 7569 -TROUBLESHOOTING
710-31 [CDL] ARC Supply Solenoid
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #11 Status
- 7569 -TROUBLESHOOTING
711-31 [CDL] ARC Control Solenoid
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #12 Status
- 7569 -TROUBLESHOOTING
712-31 [CDL] Retarder Control Lamp
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #13 Status
- 7569 -TROUBLESHOOTING
713-31 [CDL] Auto Retarder On
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #14 Status
- 7569 -TROUBLESHOOTING
714-31 [CDL] Auto Retarder Pressure Switch
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #15 Status
- 7569 -TROUBLESHOOTING
715-31 [CDL] Retarder Pressure Switch
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Auxiliary I
- Custom Event #16 Status
- 7569 -TROUBLESHOOTING
716-31 [CDL] Watt Transducer
PROCEDURE
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
- Digital Output #1 Short High
[J1939] Auxiliary Output #1
- Digital Output Circuit Fault
924-03 - 4490 - ELECTRONIC
[CDL] Burner Control Electronic Control
MODULAR CONTROL PANEL
Module
- 7566 - WIRING DIAGRAM
- Digital Output #2 Short High
[J1939] Auxiliary Output #2 - Digital Output Circuit Fault
925-03 - 4490 - ELECTRONIC
[CDL] Burner Control Diagnostic Lamp MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Auxiliary Engine
- Emergency Stop Shutdown
Shutdown Switch
- Digital Input Circuit Fault
970-31 - 4490 - ELECTRONIC
[CDL] Center
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Not Available Or Condition Exists
[J1939] Engine Alternator Bearing 1
- High Generator Bearing #1
Temperature
Temperature Shutdown
- Digital Input Circuit Fault
[CDL] Rear System High Pressure
1122-00 - Analog Input Circuit Fault
Solenoid
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Low Generator Rear Bearing
[J1939] Engine Alternator Bearing 1 Temperature Shutdown
Temperature - Digital Input Circuit Fault
1122-01 - Analog Input Circuit Fault
[CDL] Rear System High Pressure - 4490 - ELECTRONIC
Solenoid MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Generator Rear Bearing
[J1939] Engine Alternator Bearing 1 Temperature Sensor Short
Temperature High
1122-03 - Analog Input Circuit Fault
[CDL] Rear System High Pressure - 4490 - ELECTRONIC
Solenoid MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Alternator Bearing 1 - Generator Rear Bearing
1122-04 Temperature Temperature Sensor Short
Low
[CDL] Rear System High Pressure - Analog Input Circuit Fault
Solenoid - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Alternator Bearing 1
- High Rear Generator Bearing
Temperature
Temperature Warning
- Digital Input Circuit Fault
[CDL] Rear System High Pressure
1122-15 - Analog Input Circuit Fault
Solenoid
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Alternator Bearing 1
- Low Generator Rear Bearing
Temperature
Temperature Warning
- Digital Input Circuit Fault
[CDL] Rear System High Pressure
1122-17 - Analog Input Circuit Fault
Solenoid
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Alternator Winding 1
Temperature - High Generator Winding #1
Temperature Shutdown
1124-00 [CDL] Anti-Theft Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
[J1939] Engine Alternator Winding 1
Temperature - High Generator Winding #1
Temperature Warning
1124-15 [CDL] Anti-Theft Solenoid - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Alternator Winding 2
Temperature - High Generator Winding #2
Temperature Shutdown
1125-00 [CDL] Left Hand Lever Forward - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
[J1939] Engine Alternator Winding 2
Temperature - High Generator Winding #2
Temperature Warning
1125-15 [CDL] Left Hand Lever Forward - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Engine Alternator Winding 3
Temperature - High Generator Winding #3
Temperature Shutdown
1126-00 [CDL] Left Hand Lever Left - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (most severe)
1126-15 [J1939] Engine Alternator Winding 3 - High Generator Winding #3
Temperature Temperature Warning
- 7569 -TROUBLESHOOTING
[CDL] Left Hand Lever Left PROCEDURE
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] J1939 Network #2 - Accessory Data Link Fault
- Data Link Circuit Fault
1231-11 [CDL] Brake Oil Diverter Solenoid - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Failure Mode Not Identifiable - 7566 - WIRING DIAGRAM
[J1939] Engine Fuel Leakage 1 - Fuel Tank Leak (Fuel
Rupture Basin)
[CDL] Hoist Control to Tank Head - Digital Input Circuit Fault
1239-31
Solenoid - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists - 7566 - WIRING DIAGRAM
[J1939] Engine was Shut Down Hot
- Unexpected Engine
Shutdown
[CDL] Gen Stat Winding #5 Temp Sens
1383-11 - 7569 -TROUBLESHOOTING
open
PROCEDURE
- 7566 - WIRING DIAGRAM
- Failure Mode Not Identifiable
[J1939] Engine Fuel Valve 1 Inlet
Absolute Pressure
- High Gas Pressure Shutdown
[CDL] Gen Stat Winding #12 Temp - 7569 -TROUBLESHOOTING
1390-00
Sens open PROCEDURE
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (most severe)
[J1939] Engine Fuel Valve 1 Inlet
- Low Gas Pressure Shutdown
Absolute Pressure
- 7569 -TROUBLESHOOTING
1390-01
PROCEDURE
[CDL] Gen Stat Winding #12 Temp
- 7566 - WIRING DIAGRAM
Sens open
[J1939] Engine Fuel Valve 1 Inlet
Absolute Pressure
- High Gas Pressure Warning
[CDL] Gen Stat Winding #12 Temp - 7569 -TROUBLESHOOTING
1390-15
Sens open PROCEDURE
- 7566 - WIRING DIAGRAM
- Data Valid but above Normal
Operating Range (least severe)
[J1939] Engine Fuel Valve 1 Inlet
Absolute Pressure
- Low Gas Pressure Warning
[CDL] Gen Stat Winding #12 Temp - 7569 -TROUBLESHOOTING
1390-17
Sens open PROCEDURE
- 7566 - WIRING DIAGRAM
- Data Valid But Below Normal
Operating Range (least severe)
[J1939] Engine Automatic Start Failed - Engine Failure to Start
Shutdown
1664-31
[CDL] Attachment Valve #4 Retract - Engine Overcrank Warning
Pressure Solenoid - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - High Right Exhaust
Temperature - Right Manifold Temperature Shutdown
- Digital Input Circuit Fault
2433-00 [CDL] Urea Tank Level Switch - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
- Low Right Exhaust
[J1939] Engine Exhaust Exhaust Gas
Temperature Shutdown
Temperature
- Digital Input Circuit Fault
2433-01 - Analog Input Circuit Fault
- Right Manifold
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[CDL] Urea Tank Level Switch
- 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - Right Exhaust Temperature
Temperature Sensor Short High
- Analog Input Circuit Fault
2433-03
- Right Manifold - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[CDL] Urea Tank Level Switch - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - Right Exhaust Temperature
Temperature Sensor Short Low
- Analog Input Circuit Fault
2433-04
- Right Manifold - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[CDL] Urea Tank Level Switch - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas
- Right Exhaust Temperature
Temperature
Signal Abnormal
2433-08 - 7569 -TROUBLESHOOTING
- Right Manifold
PROCEDURE
- 7566 - WIRING DIAGRAM
[CDL] Urea Tank Level Switch
[J1939] Engine Exhaust Exhaust Gas - High Right Exhaust
Temperature - Right Manifold Temperature Warning
- Digital Input Circuit Fault
2433-15 [CDL] Urea Tank Level Switch - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - Low Right Exhaust
Temperature - Right Manifold Temperature Warning
- Digital Input Circuit Fault
2433-17 [CDL] Urea Tank Level Switch - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - High Left Exhaust
Temperature - Left Manifold Temperature Shutdown
- Digital Input Circuit Fault
2434-00 [CDL] Engine Load Signal - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
2434-01 [J1939] Engine Exhaust Exhaust Gas - Low Left Exhaust
Temperature Temperature Shutdown
- Digital Input Circuit Fault
- Left Manifold - Analog Input Circuit Fault
- 4490 - ELECTRONIC
[CDL] Engine Load Signal MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - Left Exhaust Temperature
Temperature Sensor Short High
- Analog Input Circuit Fault
2434-03
- Left Manifold - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[CDL] Engine Load Signal - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - Left Exhaust Temperature
Temperature Sensor Short Low
- Analog Input Circuit Fault
2434-04
- Left Manifold - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
[CDL] Engine Load Signal - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas
- Left Exhaust Temperature
Temperature
Signal Abnormal
2434-08 - 7569 -TROUBLESHOOTING
- Left Manifold
PROCEDURE
- 7566 - WIRING DIAGRAM
[CDL] Engine Load Signal
[J1939] Engine Exhaust Exhaust Gas - High Left Exhaust
Temperature - Left Manifold Temperature Warning
- Digital Input Circuit Fault
2434-15 [CDL] Engine Load Signal - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Engine Exhaust Exhaust Gas - Low Left Exhaust
Temperature - Left Manifold Temperature Warning
- Digital Input Circuit Fault
2434-17 [CDL] Engine Load Signal - Analog Input Circuit Fault
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Generator Average AC
- Generator Over Frequency
Frequency
Shutdown
- Generator Overfrequency
[CDL] Catalytic Converter Differential
2436-00 Warning
Pressure Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (most severe)
- Generator Under Frequency
[J1939] Generator Average AC Shutdown
Frequency - Generator Underfrequency
2436-01 Warning
[CDL] Catalytic Converter Differential - 4490 - ELECTRONIC
Pressure Sensor MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Generator Average AC - Engine Speed-Generator
2436-02 Frequency Output Frequency Mismatch
Warning
[CDL] Catalytic Converter Differential - Engine Speed Warning
Pressure Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Generator Average AC - Generator Output Sensing
Frequency System Failure
- Generator Output Sensing
2436-12 [CDL] Catalytic Converter Differential Circuit Fault
Pressure Sensor - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Bad Device or Component - 7566 - WIRING DIAGRAM
[J1939] Generator Average AC
- Generator Over Frequency
Frequency
Warning
- Generator Overfrequency
[CDL] Catalytic Converter Differential
2436-15 Warning
Pressure Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid but above Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Generator Average AC
- Generator Under Frequency
Frequency
Warning
- Generator Underfrequency
[CDL] Catalytic Converter Differential
2436-17 Warning
Pressure Sensor
- 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Data Valid But Below Normal
- 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Generator Average Line-Line - Generator Over Voltage
AC RMS Voltage Shutdown
- Generator Overvoltage
2440-00 [CDL] Winch Brake Solenoid Warning
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
- Generator Under Voltage
Shutdown
[J1939] Generator Average Line-Line
- Generator Undervoltage
AC RMS Voltage
2440-01 Warning
- 4490 - ELECTRONIC
[CDL] Winch Brake Solenoid
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Generator Average Line-Line - Generator Over Voltage
AC RMS Voltage Warning
- Generator Overvoltage
2440-15 [CDL] Winch Brake Solenoid Warning
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
[J1939] Generator Average Line-Line - Generator Under Voltage
AC RMS Voltage Warning
- Generator Undervoltage
2440-17 [CDL] Winch Brake Solenoid Warning
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
2448-00 [J1939] Generator Average AC RMS - Generator Over Current
Current Shutdown
- Generator Overcurrent
[CDL] Graphical Display Module Warning
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (most severe) - 7566 - WIRING DIAGRAM
[J1939] Generator Average AC RMS - Generator Over Current
Current Warning
- Generator Overcurrent
2448-15 [CDL] Graphical Display Module Warning
- 4490 - ELECTRONIC
- Data Valid but above Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
- Generator Reverse Power
Shutdown
[J1939] Generator Total Real Power
- Generator Reverse Power
2452-01 Warning
[CDL/ATA] Particulate Trap #1 Intake
- 4490 - ELECTRONIC
Temperature Sensor
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
[J1939] Generator Total Real Power
- Generator High Power
[CDL/ATA] Particulate Trap #1 Intake Warning
2452-15 Temperature Sensor - 7569 -TROUBLESHOOTING
PROCEDURE
- Data Valid but above Normal - 7566 - WIRING DIAGRAM
Operating Range (least severe)
[J1939] Generator Total Real Power - Generator Reverse Power
Warning
[CDL/ATA] Particulate Trap #1 Intake - Generator Reverse Power
2452-17 Temperature Sensor Warning
- 4490 - ELECTRONIC
- Data Valid But Below Normal MODULAR CONTROL PANEL
Operating Range (least severe) - 7566 - WIRING DIAGRAM
- Service Maintenance Interval
[J1939] Maintenance Lamp Warning
- Service Maintenance Interval
2648-31 [CDL] Cylinder #24 Injector Actuator #2 Warning
- 4490 - ELECTRONIC
- Not Available Or Condition Exists MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Engine Controller Not
Responding
3543-09 [J1939] Engine Operating State - 7569 -TROUBLESHOOTING
PROCEDURE
- 7566 - WIRING DIAGRAM
- Utility Breaker System Fault
Utility Breaker
- 7569 -TROUBLESHOOTING
3546-11
PROCEDURE
- Failure Mode Not Identifiable
- 7566 - WIRING DIAGRAM
- Engine Inlet Manifold Charge
[J1939] Inlet Manifold Charge
Combustion
Combustion
3783-31 - 7569 -TROUBLESHOOTING
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
3829-31 [J1939] EPS Supplying Load - EPS Supplying Load
- 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Custom Event #17 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3880-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #18 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3881-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #19 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3882-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #20 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3883-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #21
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3888-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #22 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3889-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #23 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3890-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #24 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3891-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #25 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3892-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #26 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3893-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #27 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3894-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #28 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3895-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #29 Status
3896-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Custom Event #30 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3897-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #31 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3898-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #32 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3899-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #33 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3904-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #34 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3905-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #35 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3906-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #36 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3907-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #37 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3908-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #38 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3909-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #39 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3910-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #40 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3911-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #41 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3912-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #42 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3913-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #43 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3914-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #44 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3915-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #45 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3920-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #46 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3921-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #47 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3922-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #48 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3923-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #49 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3924-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #50 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3925-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #51 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3926-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #52 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3927-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #53 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3928-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #54 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3929-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Custom Event #55 Status
[J1939] Auxiliary I
- 7569 -TROUBLESHOOTING
3930-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
[J1939] Auxiliary I - Custom Event #56 Status
3931-31
- 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Air Damper Closed
[J1939] Engine Exhaust Brake Enable
- Digital Input Circuit Fault
Switch
4000-31 - 4490 - ELECTRONIC
MODULAR CONTROL PANEL
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- ATS in Normal Position
ATS in Normal Position - Digital Input Circuit Fault
4001-31 - 4490 - ELECTRONIC
- Not Available Or Condition Exists MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- ATS in Emergency Position
ATS in Emergency Position - Digital Input Circuit Fault
4002-31 - 4490 - ELECTRONIC
- Not Available Or Condition Exists MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Battery Charger Failure
Battery Charger Failure - Digital Input Circuit Fault
4003-31 - 4490 - ELECTRONIC
- Not Available Or Condition Exists MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Generator Circuit Breaker
Closed
Generator Circuit Breaker Closed
- Digital Input Circuit Fault
4004-31
- 4490 - ELECTRONIC
- Not Available Or Condition Exists
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Utility Circuit Breaker Closed
Utility Circuit Breaker Closed - Digital Input Circuit Fault
4005-31 - 4490 - ELECTRONIC
- Not Available Or Condition Exists MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Engine in Cooldown
Engine in Cooldown - Engine Cooldown Warning
4006-31 - 4490 - ELECTRONIC
- Not Available Or Condition Exists MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Generator Control Not in
Automatic Warning
Generator Control Not in Automatic
- Generator Control Not in
Warning
4007-31 Automatic Warning
- 4490 - ELECTRONIC
- Not Available Or Condition Exists
MODULAR CONTROL PANEL
- 7566 - WIRING DIAGRAM
- Generator Breaker Failure to
Generator Breaker Failure to Open Open
4009-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Utility Breaker Failure to
Utility Breaker Failure to Open Open
4010-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Generator Breaker Failure to
Generator Breaker Failure to Close Close
4011-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Utility Breaker Failure to
Utility Breaker Failure to Close Close
4012-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Generator Circuit Breaker
Generator Circuit Breaker Open Open
4013-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Utility Breaker Open
Utility Breaker Open
- 7569 -TROUBLESHOOTING
4014-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
Utility to Generator Transfer Failure - Utility to Generator Transfer
Shutdown Failure Warning
4015-00 - 7569 -TROUBLESHOOTING
- Data Valid but above Normal PROCEDURE
Operating Range (most severe) - 7566 - WIRING DIAGRAM
Utility to Generator Transfer Failure - Utility to Generator Transfer
Shutdown Failure Warning
4015-15 - 7569 -TROUBLESHOOTING
- Data Valid but above Normal PROCEDURE
Operating Range (least severe) - 7566 - WIRING DIAGRAM
Generator to Utility Transfer Failure - Generator to Utility Transfer
Warning Failure Warning
4016-15 - 7569 -TROUBLESHOOTING
- Data Valid but above Normal PROCEDURE
Operating Range (least severe) - 7566 - WIRING DIAGRAM
- Loss of Utility
Loss of Utility
- 7569 -TROUBLESHOOTING
4017-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Generator Breaker Locked
Generator Breaker Locked Out Out
4018-31 - 7569 -TROUBLESHOOTING
- Not Available Or Condition Exists PROCEDURE
- 7566 - WIRING DIAGRAM
- Utility Breaker Locked Out
Utility Breaker Locked Out
- 7569 -TROUBLESHOOTING
4019-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Earth Fault
Earth Fault
- 7569 -TROUBLESHOOTING
4028-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Earth Leakage
Earth Leakage
- 7569 -TROUBLESHOOTING
4029-31
PROCEDURE
- Not Available Or Condition Exists
- 7566 - WIRING DIAGRAM
- Low Battery Cranking
[J1939] Cranking Voltage
Voltage Warning
4256-17 - 7569 -TROUBLESHOOTING
- Data Valid But Below Normal
PROCEDURE
Operating Range (least severe)
- 7566 - WIRING DIAGRAM

Component Based Troubleshooting is for technical reference only. It is not intended to replace the knowledge and skills
of the servicing technician, and does NOT imply warranty coverage.

Content Owner: Brian Hall


Caterpillar Confidential: Green
Copyright 2004 - 2011 Caterpillar Inc.
All Rights Reserved.