Job: LimconJob -- Connection: RAFI 07/20/2016


11:31:04 AM

Column: COL UB533X210X92 Gr.S275


Base plate: 280x32x700 Gr.S275 - Weld: 5 FW/440
Shear key:
Shear key welds: 5 FW/440 all around

350 350

140 80
140 80

310 310
Foundation: 1000 x 1000 x 600 deep (reinf.) - 40 thick grout pad
HD Bolts: 8 x M12 4.6/N - 450 embedment

LIMCON V3.63.1.11 {0} 20-JUL-16


11:30:20
Connection: RAFI
Type: Base Plate
2: Moment base plate
Country: UK
Units: SI metric
Design code: BS 5950

Column: Mark=COL Section=UB533X210X92 Grade=S275


D = 533 mm Root rad. = 13 mm fyf = 275 N/mm2
B = 209 mm Area = 1.1700E+04 fyw = 275 N/mm2
Tf = 15.6 mm Zx = 2072000 fu = 430 N/mm2
Tw = 10.1 mm Sx = 2360000
.Section moment capacity . . . . 649.0 kN.m Note 1
.Section shear capacity . . . . . 888.4 kN Note 2
.Section tension capacity . . . . 3217.5 kN BS5950 4.6.1
.Section compression capacity . . 3016.1 kN BS5950 4.7.4

Base plate:
700x280x32 Gr./fy/fu=S275/27/430N/mm2

Welds:
5 FW/440N/mm2 all around column.

Bolts:
8 x M12 4.6/N anchor bolts.
Bolt hole dia. . . . . . . . . . 18 mm
No. bolt rows = 3
No. bolt cols. = 3
Spacing of outer bolts, sg = 160 in XX direction.
Spacing of outer bolts, sp = 620 in YY direction.
Embedment length = 450, no hook.
Shear capacity of bolts NOT considered.

LIMCON V3.63.1.11 C:\Program Files (x86)\Bentley\Engineering\Limcon\Program\LimconJob


Pandi Page 2 of 3
Job: LimconJob -- Connection: RAFI 07/20/2016
11:31:04 AM

Shear key:
Depth, bs . . . . . . . . . . . . 1 mm
Width for strong axis shear, dsx 3 mm
Thickness, tsy . . . . . . . . . 0 mm
Width for weak axis shear, dsy . 0 mm
Thickness, tsx . . . . . . . . . 0 mm
Weld: 5 FW/440N/mm2 to base plate.

Foundation:
Foundation strength, fcu . . . . 30.0 N/mm2
Grout thickness . . . . . . . . . 40 mm
Rectangular, D . . . . . . . . . 1000 mm
B . . . . . . . . . 1000 mm
Min. bolt edge distance . . . . . 190 mm
Depth . . . . . . . . . . . . . . 600 mm
Foundation is reinforced - reinforcement not checked.
Coefficient of friction . . . . . 0.40

MINIMUM ACTION CHECK


(Minima are based on section capacity, not member capacity.)
Specified minimum design actions:
Bending 50% of Ms ( 649.0) = 324.5 kN.m
Shear 40.0 kN
Tension 0% of Ns ( 3217.5) = 0.0 kN
Compression 0% of Nc ( 3016.1) = 0.0 kN
NOTE: Input design actions are not automatically increased if they are less than
the specified minimum actions. Minimum actions may be set in any load case.
This check warns if any design action is less than the specified minimum
for all load cases.
WARNING: Design bending moment is less than specified minimum.
WARNING: Design shear force is less than specified minimum.

INPUT DESIGN ACTIONS


Axial, N . . . . . . . . . . . . -100.0 kN (comp.)
Shear, Vx . . . . . . . . . . . . 2.1 kN
Shear, Vy . . . . . . . . . . . . 1.0 kN
Moment, Mx . . . . . . . . . . . 2.50 kN.m
Moment, My . . . . . . . . . . . 0.00 kN.m

Using AISC 2006 model...

DESIGN CAPACITY CHECKS


Utilization ratio HHHHHHI
Design action HHHHI J
┌HDesign capacity J J Reference
J J J LLLLLLLLLLLLLL
NOTE: Capacity of section is not checked.

COMPRESSION + MOMENT ANALYSIS


Concrete confinement ratio . . . 1.43
Bearing strength, fp(max) . . . . 21.9 N/mm2
Foundation concentric compression capacity 4284.0 ≥ Pc = 100.0 2% Pass
Anchor bolt tension...
Min. edge distance (unreinf.) . . 72 mm ASI DG7 p.53
Bolt edge distance . . . . . . . 190 ≥ 72 Yes Informative
Strong axis bending...
Eccentricity . . . . . . . . . . 25.0 mm
Critical eccentricity . . . . . 341.8 mm SDG1 (3.3.7)
Outstand . . . . . . . . . . . . 97 mm
=== Small moment - no bolt tension ===
Concrete bearing length, Y . . . 650 mm SDG1 (3.3.8)
Concrete bearing strength, fp(max) . . . . 21.9 ≥ fp = 0.5 3% Pass SDG1 (3.3.10)
Plate bending moment (bearing) . 0.72 kN.m SDG1 (3.3.11)
Base plate yield (bearing) capacity . . . 19.7 ≥ Mpb = 0.72 4% Pass
NOTE: X and Y shear forces are resisted only by weld elements aligned in the
same direction as the shear force.
Column weld capacity . . . . . . . . . . . 0.778 ≥ vres = 0.003 0% Pass

SHEAR ANALYSIS

CHECK 4 - Shear Transfer by Friction:


Slip factor . . . . . . . . . . . 0.40
Compression force . . . . . . . . 100.0 kN
Available base plate friction . . . . . . . 28.0 kN
Design shear less friction (x) . 0.0 kN

LIMCON V3.63.1.11 C:\Program Files (x86)\Bentley\Engineering\Limcon\Program\LimconJob


Pandi Page 3 of 3
Job: LimconJob -- Connection: RAFI 07/20/2016
11:31:04 AM

Design shear less friction (y) . 0.0 kN

CHECK 6 - Shear Transfer by Shear Key:


Shear key y direction capacity...
WARNING: Shear key wholly within grout.

Total (y) shear capacity . . . . . . . . . 28.0 ≥ Vy = 1.0 4% Pass


Total (x) shear capacity . . . . . . . . . 28.0 ≥ Vx = 2.1 7% Pass

NOTES:
1. Flexural yield capacity ignoring section slenderness.
2. Shear yield capacity ignoring slenderness.

CRITICAL LIMIT STATE . . . Total (x) shear capacity


UTILIZATION RATIO . . . . 7%
CAPACITY RATIO . . . . . . 13.333 Pass