For example, when you have a report that presents regional sales status, it is possible to
make a report of selected area by using parameter value. In this case, parameters, /rp and
/rv, will be used as ‘parameter value set’.
81
Appendix III. Report Designer Parameters
/rpaper
/rpaperlength
/rpdrv
/rpdup
/rpdupex
/rpprnform
/rprintnexit
/rprnend
/rprnfile
/rprnjangopt
/rprnn
/rprno
/rprns
/rprnstart
/rps
/rpsrc
/rpuserpaper
/rpxpos
/rpypos
/rskippbline
/rcsv
/rcsvopt
/rexport
/rpdfnf
/rrunscr
/rsavedialogtype
Save /rsavepdf
/rsep
/rtagname
/rxls
/rxlsfullhorz
/rxlsnopb
/rxlsopt
/rcomboautorefresh
Inquiry Toolbar /rcombononullstr
/rcomboselectfirststr
/rchartactive
/rchartaxismax
/rchartaxismin
Chart /rchartlabelmax
/rchartlabelmin
/rchartmarkpos
/rsetmaxganttcount
/rpd
If Statement Parameter Input
/rpmd
/rpn
82
Appendix III. Report Designer Parameters
/rpt
/rp
Set Parameter Value /rpp
/rv
/rautoadjust
/rbrowsingopt
/reditmode
/rfixallobject
/rhcd
/rhidelinkinfo
/rhlinkopt
/ri
Environment
/rmaketree
/rmessageboxshow
/rmvs
/rnpu
/rpartsavedialog
/rsave
/rtrace
/rtracefile
/radocmdtimeout
/radocontimeout
/rcontype
/rdn
DB connection
/rip
/rpw
/rsn
/rui
/rcss
HTML Source Conversion /rhtmlimportopt
/rstyle
83
Appendix III. Report Designer Parameters
By using blank space, it is possible to select several parameters together. Parameter Names
start with /r (except /p). Parameter value does not exist or may have several values
depending on parameters.
Refer to the following Description of parameters for the value setting of parameter.
84
Appendix III. Report Designer Parameters
3.1.1. /p
Instruction
/p
Description
Parameter for producing report and for making print-out of the report.
This parameter is used only in Report Designer EXE Viewer and make it run in hiding of
Report Designer EXE Viewer. If you want to run the report in condition of using Report
Designer OCX Viewer, you need to use /rop parameter.
Notice. You must input /p parameter before a report file name. If you need to input different
parameters in order to run the report, you may input different parameters after file name like
in the following example /rp [car].
Example
85
Appendix III. Report Designer Parameters
3.1.2. /radocmdtimeout
Instruction
Description
When you execute ADO connection report, setup time limit in executing query statements.
Default value is 30 seconds, and it is used for the case of executing query statements over
30 seconds.
Example
/radocmdtimeout [1000]
3.1.3. /radocontimeout
Instruction
Description
When you execute ADO connection report, setup database connection time limit.
Default value is 30 seconds, and it is used for the case of connecting database over 30
seconds.
Example
/radocontimeout [50]
86
Appendix III. Report Designer Parameters
3.1.4. /rallprn
Instruction
/rallprn
Description
When you print a report, if this parameter is used with /rop parameter, page-print starts once
the whole pages of report are completed.
Example
/rop /rallprn
87
Appendix III. Report Designer Parameters
3.1.5. /rautoadjust
Instruction
Description
It automatically adjust the ratio of a Report Designer Viewer according to the size of a screen.
If set 1, the ratio will set automatically adjusted to fit in the size of a screen. Otherwise, it will
apply 100% ratio.
cf. Auto-ratio adjustment in Report Designer OCX Viewer can also be set by using
AutoAdjust properties values.
Example
/rautoadjust [1]
One in the left is a screen capture before applying /rautoadjust, and the other in the right is a
screen capture after using /rautoadjust for automatically adjust.
88
Appendix III. Report Designer Parameters
3.1.6. /rbrowsingopt
Instruction
Description
In executing mode when you view a report, /rbrowsingopt is used for mouse dragging
functions.
If value is 1, you can block for text copy on text frame object and cell object of table by
mouse dragging. In other cases, screen scroll function will be executed.
Example
/rbrowsingopt [1]
By using this parameter, blocks are shown by mouse dragging as shown below.
89
Appendix III. Report Designer Parameters
3.1.7. /rchartactive
Instruction
/rchartactive
Description
/rchartactive is a parameter that makes chart object to activate status. This parameter allows
to use the functions of chart object without double clicking chart object.
Example
/rchartactive
3.1.8. /rchartaxismax
Instruction
Description
Its priority is ahead of the maximum value in chart editing dialog box.
Example
/rchartaxismax [500]
90
Appendix III. Report Designer Parameters
3.1.9. /rchartaxismin
Instruction
Description
Its priority is ahead of the minimum value in chart editing dialog box.
Example
By using parameters above, the maximum and the minimum values will be applied as shown
below.
91
Appendix III. Report Designer Parameters
3.1.10. /rchartlabelmax
Instruction
Description
When Label of X axis in chart is date format, it sets up the maximum date.
Example
3.1.11. /rchartlabelmin
Instruction
Instruction
When Label of X axis in chart is date format, it sets up the minimum date.
Example
92
Appendix III. Report Designer Parameters
3.1.12. /rchartmarkpos
Instruction
Description
It is a parameter that controls Y-position of ‘Mark’ when you mark in chart series.
If you select a positive value, mark position will move up-ward and if you select negative
value the mark position will move down-ward.
Example
/rchartmarkpos [10]
3.1.13. /rcomboautorefresh
Instruction
/rcomboautorefresh
Description
When display tool bar has several display combo box, and if values in one combo box changes,
the list in the related combo box automatically changes.
For example, the name of country, city and client numbers are in display combo box, and
you change the country from USA to Korea, then the city name list will automatically changes.
It is assumed that the query statement for city name is related to country name.
In case you do not use parameter above, when you change country name, city name list will
not change, but when you change city name, city name display combo box will be refreshed.
Example
93
Appendix III. Report Designer Parameters
3.1.14. /rcombononullstr
Instruction
/rcombononullstr
Description
Basically, the first one in display combo box list adds blank. This parameter controls not to
add blank.
By applying this parameter, combo box will look like the picture in the right.
Example
3.1.15. /rcomboselectfirststr
Instruction
/rcomboselectfirststr
Description
When display tool bar has several display combo box, if the selection in one combo box
changes, the first one in another related combo box list will be selected.
By applying this parameter, combo box will look like the picture in the right.
Example
94
Appendix III. Report Designer Parameters
3.1.16. /rcontype
Instruction
Description
This parameter can be used in reports that are using SQL statement or Stored Procedure.
For example, ODBC connection is used for making mrd file in Report Designer Editor, and
when execution in Report Designer Viewer, it is possible to make report in RDAGENT
connection.
Available connection moods are RDAGENT, NET, ODBC, ADO, ORACLE, ORACLE8,
ORACLE8I, RDS, SYBASE, SYBASE11.
You need more parameters below to execute reports in selected connection methods.
/rcontype [ORACLE8I] /rsn [service name] /rui [user ID] /rpw [password]
/rcontype [SYBASE11] /rsn [service name] /rui [uesr ID] /rpw [password] /rdn [database
name]
cf. Refer to the Descriptions of /rf, /rsn, /rui, /rpw, /rdn parameters used with /rcontype
respectively.
Example
95
Appendix III. Report Designer Parameters
3.1.17. /rcsv
Instruction
Description
When you execute a report, it saves data from data source into a text file.
Example
3.1.18. /rcsvopt
Instruction
Description
This is used with /rcsv parameters, and it appoints data saving method.
If the value is 0, and if there are new line character, comma(,), double quotation mark(“) in
the data, it binds and saves the corresponding column data using double quotation mark(“).
(default)
If the value is 1, it does not handle column data in any other way.
Example
96
Appendix III. Report Designer Parameters
3.1.19. /rdata,
Instruction
Description
It is a parameter used in FILE connection and XMLFILE connection, and appointing data set
needed for executing reports.
cf. There are two parameters /rf and /rdata for appointing data source in FILE connection
and XMLFILE connection.
/rdata is to transmit existing data set while executing a report and Report Designer Viewer
produce reports using data set.(PUSH method)
/rf is to transmit the path of data set while executing a report. It creates report by bringing
data set through the appointed path in Report Designer Viewer. (PULL method)
When you have massive amount of data output, use /rf because it creates report by patching
data partially. In this functional advantage, /rf is better than /rdata.
Example
<!--
function JavaOpen2_OnClick() {
var tmpStr;
97
Appendix III. Report Designer Parameters
// alert(tmpStr);
Rdviewer.FileOpen("C:\\transcript.mrd", tmpStr);
-->
</SCRIPT>
98
Appendix III. Report Designer Parameters
3.1.20. /rdelnodatamsg
Instruction
/rdelnodatamsg
Description
When the number of data at the repeating section in ‘Table’ type report are 0, it merges all
the cell and shows ‘Query data does not exist.’ in the cell. (Default)
If /rdelnodatamsg parameter is used, it will display already designed table form without
performing function above.
It performs the same function when clear the check box of ‘Combine Repetitions’ in Set Table
Properties dialog box.
Example
/rdelnodatamsg
3.1.21. /rdn
Instruction
Description
When executing a report, this parameter is used to change the name information of
database that is to be used in the report.
Example
99
Appendix III. Report Designer Parameters
/rcontype [SYBASE11] /rsn [service name] /rui [user’s ID] /rpw [password] /rdn [database
name]
100
Appendix III. Report Designer Parameters
3.1.22. /rdonotreport
Instruction
/rdonotreport
Description
This parameter controls not to execute a report but just to open a form file.
It is for presenting an empty form file on the screen and for executing a report after inputting
inquiry condition in display tool bar.
Left side is a report created with this parameter. Right side is a report created after inputting
inquiry condition.
Example
3.1.23. /rdonotreportex
Instruction
/rdonotreportex
Description
It functions the same as /rdonotreport parameter. If it is applied for a file that does not use /rp
parameter variable, the reports are executed without considering parameter.
Example
101
Appendix III. Report Designer Parameters
3.1.24. /reditmode
Instruction
/reditmode
Description
Report Designer Viewer provides execution mode and editing mode. In execution mode,
only displaying a report is available. In editing mode, both displaying and editing is available
and the execution mode is a default. To execute a report in editing mode, use this
parameter.
Editing mode is only available when ‘Modify final report’ or ‘Enable memo on final report’ in
‘File-Document properties-Document’ tab of Report Designer Editor is set.
Example
/reditmode
3.1.25. /rexec
Instruction
Description
Example
/rexec [c:\a.xls]
102
Appendix III. Report Designer Parameters
3.1.26. /rexport
Instruction
Description
When you print a report, use /report to save as a local file instead of sending to print.
Example
/rexport [2,c:\11.xls]
103
Appendix III. Report Designer Parameters
3.1.27. /rf
Instruction
/rf [data source path or RDAGENT server path or .NET server path]
Description
It is available in FILE connection way and XMLFILE connection way to select a data source
path for executing a report.
Data source file can be local file, web URL or server script URL.
/rf [c:\tst.txt] //local file. After reporting, local file will be automatically deleted.
/rf [<%=serverIp%>/reports/data.jsp?empno=<%=empno%>&deptno=<%=deptno%>]
//server script URL
parameters in executing a server script can be changed to GET form and POST form.
transition to GET form has 255 byte size limit. Transition to POST form has no size limit.
Refer to /rpost parameter Description.
server script called by /rf parameter print the data set for FILE connection path and XMLFILE
connection path.
Below is a part of JSP server script that prints set in FILE connection path.
104
Appendix III. Report Designer Parameters
<%
String dno = request.getParameter("dno");
if (conn.isClosed() ) {
conn = conn = DriverManager.getConnection( DB_URL, user, passwd );
}
ResultSet empCursor = null;
try {
stmt =
conn.createStatement(ResultSet.TYPE_SCROLL_INSENSITIVE,ResultSet.CONCUR_U
PDATABLE);
empCursor = stmt.executeQuery( sql.toString() );
while( empCursor.next() ) {
out.println(empCursor.getString("empno") + "^" +
empCursor.getString("ename") + "^" + empCursor.getString("job") + "^" +
empCursor.getString("mgr") + "^" + empCursor.getString("hiredate") + "^" +
empCursor.getString("title") + "^");
}
empCursor.close();
stmt.close();
} catch (Exception e) {
out.println("Error!<br>" + e.toString());
}
%>
3^Steven^Helmets^Mathematics^1993/04/01^Sales Representative^
4^ Gerry^Helmets^Economics^1995/05/03^Sales Representative^
105
Appendix III. Report Designer Parameters
there are two kinds of parameter to setup data source; /rf and /rdata in FILE connection
path, XMLFILE connection path. Refer to /rdata parameter Description.
It is available in RDAGENT connection form or NET connection form, selecting server URL.
Example
106
Appendix III. Report Designer Parameters
3.1.28. /rfetchdatafirst
Instruction
/rfetchdatafirst
Description
For quick printing, Report Designer patches part of data, and then present on the screen and
continue to produce a report. However, /rfetchdatafirst parameter controls to present after
patching all data. Do not use /rfetchdatafirst in quick printing.
Example
/rfetchdatafirst
3.1.29. /rfirstmrd
Instruction
/rfirstmrd
Description
It is available when you open file lists with RprFileOpen Method. It will execute the first
report among the file list.
Example
107
Appendix III. Report Designer Parameters
3.1.30. /rfixallobject
Instruction
/rfixallobject
Description
In editing mode, it keeps objects like text frame, table and lines not to selected and move..
Example
/rfixallobject
3.1.31. /rfn
Instruction
/rfn [data source path or RDAGENT server path or .NET server path]
Description
Its function is same as /rf parameter. It only function differently in using Local file as a data
source. To use /rf parameter, delete local file after completing a report. In a case using /rfn
parameter, do not delete.
Example
108
Appendix III. Report Designer Parameters
3.1.32. /rfnodata
Instruction
Description
It present selected mrd file instead when the number of record is 0 from data source.
Example
/rfnodata [c:\nodata.mrd]
3.1.33. /rhcd
Instruction
/rhcd
Description
Executing a report without using /rhcd parameter makes dialog boxes like ‘database
connecting’ or ‘presenting report’ appear on the screen. And when there is no referred
information, dialog box saying ‘no data found’ will appear.
Note) it is same as setting Report Designer OCX Viewer’s IsShowDlg attribute value to false.
Example
/rhcd
109
Appendix III. Report Designer Parameters
3.1.34. /rhidelinkinfo
Instruction
/rhidelinkinfo
Description
When a mouse is upon hyperlink attributed object, it is a parameter to hide the information
presented in condition bar.
Example
/rhidelinkinfo
3.1.35. /rhlinkopt
Instruction
/rhlinkopt [0(default) or 1]
Description
It is a parameter to appoint whether single mouse click or double mouse click is set to work
when moving by hyperlink.
Example
/rhlinkopt [1]
3.1.36. /rhtmlimportopt
Instruction
Description
110
Appendix III. Report Designer Parameters
Example
/rhtmlimportopt [1]
111
Appendix III. Report Designer Parameters
3.1.37. /ri
Instruction
Description
Report Designer Viewer has rdviewer.ini as configuration setup. By using this parameter, you
can use INI file as a configuration setup file. In INI file, you can setup database, IP, PORT,
User Name, service port, server version.
Example
/ri [c:\tmp\rdviewer.ini]
112
Appendix III. Report Designer Parameters
3.1.38. /rinslastpage
Instruction
/rinslastpage
Description
It is used in both side printing, assuming last page as new paper and putting in every second
printing.
Example
/rinslastpage
3.1.39. /rip
Instruction
Description
It changes server IP or host name that are for connecting database in executing a report.
Example
113
Appendix III. Report Designer Parameters
3.1.40. /rl
Instruction
Description
In designing a report, it selects security level to data field for some group of users, and it
presents and hides data according to security level selected data for user and their level.
In designing a report, use formatting> security level menu and select security level in text
frame or table.
In executing a report, setup user’s level by using /rl parameter. When user’s level is lower
than the level assigned in data field, the data will secured. ‘ward order for security level’ will
appear in successfully secured data field.
Example
114
Appendix III. Report Designer Parameters
115
Appendix III. Report Designer Parameters
3.1.41. /rloginid
Instruction
Description
It is to present report user’s information, selected user’s ID will be used in two different
function.
1. In referring report, printing, saving, it present user’s information to log in server side.
2. check if a user has execution right in executing a report connected with documents
control.
: documents control server controls user’s execution right. As shown below, when report
execution is ordered, if tester user has right to execute test.mrd documents, it execute s a
report.
Example
/rloginID [tester]
116
Appendix III. Report Designer Parameters
3.1.42. /rmaketree
Instruction
/rmaketree
Description
It executes making content right after executing a report. It is used in executing a selected
content field report.
After completing a report, to make content at a point you want, use ShowIndexTree(1);
method.
Example
/rmaketree
3.1.43. /rmergecellopt
Instruction
Description
For the cases when two rolls has repeated roll, and two different cells have different field
name, this parameter merge cells.
If you use /rmergecellopt [0], even when above and below cell data’ value are same but has
different field name, it does not merge cells.
117
Appendix III. Report Designer Parameters
Example
/rmergecellopt [0]
118
Appendix III. Report Designer Parameters
3.1.44. /rmessageboxshow
Instruction
Description
Example
/rmessageboxshow [1]
3.1.45. /rmvs
Instruction
/rmvs
Description
Example
/rmvs
119
Appendix III. Report Designer Parameters
3.1.46. /rnl
Instruction
Description
In creating a report of FILE connection method, it used with /rdata parameter and assigns
NewLine character and substitution character(col). It recognizes substitution character(col)
from /rdata parameter as new line, then execute a report.
Example
3.1.47. /rnodatastring
Instruction
/rnodatastring [sting]
Description
It is a parameter to assign a string that there are no matched data after requesting search.
It has a higher priority than the string set in ‘Set Table Properties’ dialog box, and it only
works when checked at ‘Combine Repetitions’ option.
Description
3.1.48. /rnpu
Instruction
/rnpu
Description
It controls not to appear Pop-up menu when you press right click of mouse in Report
Designer Viewer.
Example
120
Appendix III. Report Designer Parameters
/rnpu
3.1.49. /roncemappingdata
Instruction
/roncemappingdata
Description
When the data set is connected to the background object, in default, data mapping is
performed every record handling. If this parameter is used when the number of records are
high, the report processing speed will be enhanced,
Example
/roncemappingdata
121
Appendix III. Report Designer Parameters
3.1.50. /ronepgrpt
Instruction
/ronepgrpt
Description
Basically, report is created in several papers as pager size. However, by using this parameter,
page extends to a size that can print whole report. It is used in executing a report for screen
viewer and same as selecting ‘one page print’ in document attribution.
when you print our a report by printer, you can adjust the printing size or divide to several
parts to print 100% of it. Use /rremakerpt parameter to print 100% size by dividing several
parts.
Example
/ronepgrpt /rremakerpt
122
Appendix III. Report Designer Parameters
3.1.51. /ronepgrptex
Instruction
/ronepgrptex
Description
But, if a condition of changing page is selected in a table document report using sub-page, it
functions differently.
If you use /ronepgrpt parameter, a report will execute d without considering page change.
Otherwise, if you use /ronepgrptex parameter, it will execute with page change condition.
At this point, the object applied page change condition has to be ’sub-page object’. Refer to
sub-page object in object properties description.
Left picture is a example created with /ronepgrpt parameter. Right picture is an example
created with /ronepgrptex parameter.
Example
/ronepgrptex
123
Appendix III. Report Designer Parameters
3.1.52. /rop
Instruction
/rop
Description
Therefore, it starts printing as you create the first page of the report. But if you use this
parameter with /rallprn parameter, it functions differently.
cf. If you use /rwait parameter in executing a report in Report Designer OCX Viewer,
FileOpen method does not change value until the complement of report execution (until all
the pages are made). Basically, /rwait is used with /rop parameter to print several reports at
once.
Example
124
Appendix III. Report Designer Parameters
3.1.53. /rp
Instruction
/rp [$1parameter value] [$2 parameter value] [$3 parameter value] .. [$N parameter value]
Description
Provide several parameter values in order and distinguish each parameter value with blank.
Put ‘[‘ before a parameter value and put ‘]’ after the parameter value.
Set /rp or /rv as you execute a report, then parameter value will be decided. Refer to
parameter name and design the report.
/rp and /rv is for providing parameter value. /rp is only available for parameter value.
Parameter name is already defined as $1, $2 .. /rv is for providing both parameter name and
value. Refer to /rv parameter Description.
SELECT Customers.CompanyName
FROM Customers
WHERE Customers.City = ':($1)' AND Customers.ContactTitle = ':($2)'
ORDER BY Customers.CompanyName ASC
125
Appendix III. Report Designer Parameters
Example
/rp [SEOUL] [salesman] //$1 parameter value : SEOUL, $2 parameter value : salesman
Report provided with parameter value $1, $2 and created with SQL, is the picture below. It
presents parameter value $1, $2 at the cell of a table.
126
Appendix III. Report Designer Parameters
3.1.54. /rpageorder
Instruction
Description
Example
/rpageorder [3,3,1] //make 3rd page to be printed out two times and then first page one time.
In this case, 2nd page is deleted.
3.1.55. /rpaper
Instruction
Description
cf. use /rpaper, /rpprnform parameter to set a paper size. Refer the Description of /rpprnform
parameter.
Example
/rpaper [A3]
127
Appendix III. Report Designer Parameters
3.1.56. /rpaperlength
Instruction
Description
It setups vertical size of a paper to 1/10mm scale, and is used for printing rolled paper. When
you print rolled paper, it protects not to change page space as page changes.
Example
/rpaperlength [2970]
3.1.57. /rpartsavedialog
Instruction
Description
Present page as a default value; select 0. Some other page as a default value; select 1.
Page number and rage are decided with comma(,) as a separator. ex)3,5-8
Example
128
Appendix III. Report Designer Parameters
3.1.58. /rpd
Instruction
/rpd [$1parameter default value] [$2parameter default value] [$3 parameter default value]..
[$N parameter default value]
Description
It is to set $parameter default value. Dialog box ‘set condition for parameter’ will pop-up for
putting parameter value if you do not give /rp parameter after you use parameter value in
designing a report.
/rpd parameter makes default value to be presented in the entry box of dialog box.
Example
129
Appendix III. Report Designer Parameters
3.1.59. /rpdfnf
Instruction
/rpdfnf
Description
It controls not to include font information when you save a report in PDF file form.
Example
/rpdfnf
3.1.60. /rpdrv
Instruction
Description
Example
130
Appendix III. Report Designer Parameters
3.1.61. /rpdup
Instruction
/rpdup
Description
Example
/rpdup
3.1.62. /rpdupex
Instruction
/rpdupex
Description
It is used for printing both sides in a table document using sub-page. This is an extended
version of /rpdup parameter.
By using /rpdup parameter; Odd number pages will print at the front page. Even number
pages will print at the back of the paper. However, /rpdupex parameter always print the first
sub-page at the front.
For example, A person’s result is 1 page, and B person’s result is 2 pages, /rdupex
parameter makes B person’s first page to be printed 2nd paper’s front page.
Example
/rpdupex
131
Appendix III. Report Designer Parameters
3.1.63. /rpmd
Instruction
Description
To sep up a value, use combo box. It will show lists available for easy entry. There are 3
ways to fill in the combo box list.
1) Use S option
It setups SQL query document with option value and fill combo box list with performed query
statement set.
User sets value that will presented at a list of a combo box and value that will be used as a
$parameter value in query execution . Set @ as a separator as shown below
User set value that will display in a list of a combo box as a option value. M option sets
display value and internal value together, but d option only sets displaying value. Value set
as a displaying value in D option will also be used as a internal value.
Example
/rpd [Nampa] /rpn [enter city name] /rpt [select query condition] /rpmd s[SELECT distinct
Customers. City FROM Customers ORDER BY Customers. City ASC] // filling value with
using S optin
/rpd [Nampa] /rpn [enter city name] /rpt [select query condition] /rpmd
M[Nampa@100@Santa Ana@200@Tualatin@300] // filling value with using M option.
132
Appendix III. Report Designer Parameters
/rpd [Nampa] /rpn [enter city name] /rpt [select query condition] /rpmd D[Nampa@Santa
Ana@Tualatin] //filling value with using D option.
133
Appendix III. Report Designer Parameters
3.1.64. /rpn
Instruction
/rpn [$1parameter title] [$2 parameter title] [$3 parameter title].. [$N parameter title]
Description
In designing a report, even if you use parameter name in query definition, ‘enter parameter
condition ‘ dialog box will appear for entering a parameter value at least you give /rp
parameter in executing a report.
you can change ‘enter value of parameter $1’ title by using /rpn parameter.
Example
134
Appendix III. Report Designer Parameters
3.1.65. /rpost
Instruction
Description
It is used with /rf parameter to transform a parameter that is necessary in calling server script,
to POST way. There is no limit in a length of transforming to POST way.
Example
3.1.66. /rposttype
Instruction
/rposttype [Content-Type]
Description
Example
/rposttype [text/xml]
135
Appendix III. Report Designer Parameters
3.1.67. /rpp
Instruction
Description
It is a extended version of /rp, and used to give parameter value in report execution .
/rp gives only parameter value, however, /rpp gives both parameter form and parameter
value.
Example
/rpp [2|7369]
136
Appendix III. Report Designer Parameters
3.1.68. /rpprnform
Instruction
Description
/rpaper parameter is to set paper size that is provided from Report Designer; set one among
A1,A2,A3,A4,A5,B4,B5,LETTER,136blank,80blank .
but, /rpprnform parameter sets ’user defined paper name’. User can set user define paper
size at printer driver. It is possible to use from Window XP, 2000.
Example
/rpprnform [SIZE1]
137
Appendix III. Report Designer Parameters
3.1.69. /rprintnexit
Instruction
/rprintnexit
Description
It is used to finish a viewer in viewer execution module. Basically it is used with /rop
parameter.
Example
/rop /rprintnexit
3.1.70. /rprnend
Instruction
Description
Example
138
Appendix III. Report Designer Parameters
3.1.71. /rprnfile
Instruction
Description
Example
/rprnfile [c:\test.ps]
3.1.72. /rprnjangopt
Instruction
/rprnjangopt
Description
It makes first serve page to be printed at the first page. It is used in printing table documents
that uses serve page.
For example, a report for A student is made 3 pages, and a report for B student is made 3
pages.
Basically, each page become 2 pages. Therefore it becomes 3 pages printed out. But, by
using /rprnjangopt parameter, it prints first and second page of A student in one paper.
Example
/rprnjangopt
139
Appendix III. Report Designer Parameters
3.1.73. /rprnn
Instruction
Description
Example
/rprnn [2]
3.1.74. /rprno
Instruction
Description
If you print only object, it does not print text data. If you print only data, it prints out only text
data.
Example
/rprno [1]
140
Appendix III. Report Designer Parameters
3.1.75. /rprns
Instruction
/rprns
Description
It is used with /rop parameter, opening a printing dialog box before printing our. It has the
same function as /rps parameter.
Example
/rop /rprns
3.1.76. /rprnspno
Instruction
Description
It sets ’beginning page number’ when report has page number object.
In designing a report, to set ‘beginning page number, use text frame properties dialog box.
/rprnspno parameter is used in executing a report to change page number.
Example
/rprnspno [10]
141
Appendix III. Report Designer Parameters
3.1.77. /rprnstart
Instruction
Description
It is used with /rop parameter to set the first page number for printing.
Example
3.1.78. /rps
Instruction
/rps
Description
It is used with /rop parameter, opening a printing dialog box before printing out. Its function is
the same as /rprns parameter.
Example
/rop /rps
142
Appendix III. Report Designer Parameters
3.1.79. /rpsrc
Instruction
Description
Example
/rpsrc [3]
143
Appendix III. Report Designer Parameters
3.1.80. /rpt
Instruction
Description
In designing a report, you use $parameter name for query definition. However, in executing a
report, if you do not give /rp parameter , dialog box saying ‘enter parameter condition’ will
appear.
You can change a title of a dialog box ‘enter parameter condition.’ by using /rpt parameter.
Example
/rpd [SEOUL] [salesman] /rpn [enter city name] [enter representative] /rpt [select inquiry
condition]
144
Appendix III. Report Designer Parameters
3.1.81. /rpuserpaper
Instruction
/rpuserpaper [value]
Description
It is to print report which size is defined by user. It is used with /rpaperlength option. If you
use specific printer diver in a condition of Windows 98, page spare could be different even
though you give /rpaperlength option. To keep it not to do this, give 256 as a /rpuserpaper
value.
Example
3.1.82. /rpw
Instruction
/rpw [password]
Description
It is used with /rui parameter and sets user password for database connection.
Example
145
Appendix III. Report Designer Parameters
3.1.83. /rpxpos
Instruction
Description
Example
/rpxpos [10]
3.1.84. /rpypos
Instruction
Description
Example
/rpypos [10]
146
Appendix III. Report Designer Parameters
3.1.85. /rremakerpt
Instruction
/rremakerpt
Description
It is used with /ronepgrpt parameter to divide one page report to several pages for print out
one report into several pages .
But, the report that has DrillDown function, /rremakerpt parameter cannot be used.
Example
/ronepgrpt /rremakerpt
3.1.86. /rrunscr
Instruction
Description
It is used in table document with ‘script use’ and saves data after script execution to a file.
This file’s field separator is ‘@’ . To change field separator, use /rsep parameter.
Example
147
Appendix III. Report Designer Parameters
3.1.87. /rsave
Instruction
/rsave
Description
It makes saving menu inactive, so that executed report will not be saved as a file.
Example
/rsave
3.1.88. /rsavedialogtype
Instruction
/rsavedialogtype [0(default) or 1]
Description
This parameter makes it possible to eliminate the password setting UI when saving MRR file
in save dialog box.
If option is 1, save dialog box that does not have ‘Set password for MRR File’ pops up.
Example
/rsavedialogtype [1]
148
Appendix III. Report Designer Parameters
3.1.89. /rsavepdf
Instruction
Description
In viewer executing module, it is used with /p parameter to save execute d report as PDF file
instead of printing a report.
Example
149
Appendix III. Report Designer Parameters
3.1.90. /rsep
Instruction
Description
This parameter is used when running File connection or XMLFile connection report, and set
file connection field separator in run time.
In executing a table document with ‘script use’, it is used with /rrunscr parameter to set field
separator for data file.
Example
/rsep [^@^]
3.1.91. /rsequrity
Instruction
Description
Field name that you give over with /rsequrity parameter will present ‘ward order in applying
security level’ instead of presenting data. Field name is set in ‘Map Dataset ’ dialog box.
cf. There are /rl and /rsequrity that is to secure data field.
150
Appendix III. Report Designer Parameters
Example
/rsequrity [orders.Freight]
151
Appendix III. Report Designer Parameters
3.1.92. /rsetmaxganttcount
Instruction
/rsetmaxganttcount
Description
Example
/rsetmaxganttcount [8]
3.1.93. /rskippbline
Instruction
/rskippbline
Description
It controls not to function ‘Page Break on Printing’ in executing a report that uses sub-page.
For example, creating bank account table, use /rskippbline parameter to print as it shows on
a screen. Otherwise, saving function will change page.
Example
152
Appendix III. Report Designer Parameters
/rskippbline
153
Appendix III. Report Designer Parameters
3.1.94. /rsn
Instruction
Description
Available connection methods are RDAGENT, NET, ODBC, ADO, ORACLE, ORACLE8,
ORACLE8I, RDS, SYBASE, SYBASE11
/rsn [service name] /rui [user ID] /rpw [password] /rdn [database name] //SYBASE11
Example
154
Appendix III. Report Designer Parameters
3.1.95. /rstyle
Instruction
Description
Example
3.1.96. /rswapfilepage
Instruction
/rswapfilepage [# of pages]
Description
This parameter is used with /ruseswapdisk parameter and assigns the number of pages that
saved in each swap file. The minimum and maximum number of pages are 100 and 1000
pages, respectively.
Example
/rswapfilepage [300]
3.1.97. /rtagdata
Instruction
/rtagdata
Description
It is used in executing a FILE connection report. It marks the beginning and the end of data
by put specific tag in data file.
155
Appendix III. Report Designer Parameters
Example
/rtagdata
156
Appendix III. Report Designer Parameters
3.1.98. /rtagname
Instruction
Description
It is used to save execute d report as XML file. It setups data file that has XML tag name
information.
Employees.LastName,name
Employees.HomePhone,phone number
Example
/rtagname [http://myserver/tagname.txt]
157
Appendix III. Report Designer Parameters
158
Appendix III. Report Designer Parameters
3.1.99. /rtrace
Instruction
Description
0:OFF(default value) ,1:Error, 2:Error & Warning, 3:Error & Warning & Info
It you do not use /rtracefname, it will create log file which from is after c:\ root directory.
Example
/rtrace [1] //c: rdvlog_20060131.log form’s log file will be created in root directory.
3.1.100. /rtracefname
Instruction
Description
Log file will be produced by date and producing rule is same as shown below.
Example
159
Appendix III. Report Designer Parameters
3.1.101. /rui
Instruction
/rui
Description
Example
3.1.102. /ruploadurl
Instruction
Description
In uploading local file to server by using UploadDataFile() of Report Designer OCX Viewer, it
setups URL of jsp and asp.
Example
/ruploadurl [http://www.m2soft.co.kr/upload/uploadf.jsp]
3.1.103. /ruseswapdisk
Instruction
/ruseswapdisk
Description
This parameter is used to create swap file in hard disk not using memory swap when printing
large volume of data. Swap file is created in Tmp directory.
Example
/ruseswapdisk
160
Appendix III. Report Designer Parameters
3.1.104. /rv
Instruction
Description
/rp only gives parameter value, /rv gives both parameter name and parameter value.
SELECT Customers.CompanyName
FROM Customers
WHERE Customers.City = ':(city name)' AND Customers.ContactTitle =
':(representative)'
ORDER BY Customers.CompanyName ASC
Use data set connection dialog box to print parameter value in data field. In creating a
summary, to refer parameter, use getparam(“parameter name”). In fixed form script, to refer
parameter name, use getparam(“parameter name”) .
161
Appendix III. Report Designer Parameters
Example
162
Appendix III. Report Designer Parameters
3.1.105. /rw
Instruction
Description
It ignores WHERE, ORDER BY, GROUP BY, HAVING of query statements in Query
definition of Report Designer Editor and change query statement with WHERE sentence that
is from parameter.
If you created Query definition in SQL editing mode, by using /rw parameter you can give all
the SQL documents over. However, it is limited to the case of already set query statement.
/rw parameter will applied to main query statement when a table documents use sub-page.
Example
/rw [SELECT t,f1, t.f2 FROM t WHERE t.f1 = 123] //SQL In free editing, all the SQL
documents will provided.
3.1.106. /rwait
Instruction
/rwait
Description
It calls file open method, and after a report completed it finishes method with using /rwait
parameter.
Basically, if it calls FileOpen method, right after the first page completed, function finishes.
Unfinished report will be produced through Background Processing in idle time.
Example
163
Appendix III. Report Designer Parameters
3.1.107. /rxls
Instruction
/rxls
Description
It saves to excel file after completing all the pages at a viewer. It will show the excel file by
executing excel program. If you use with /rcsv option, excel program that is set in /rcsv
option will be executed together.
Example
/rxls
3.1.108. /rxlsfullhorz
Instruction
Description
When you save in excel file, if you have a object out of paper range, it automatically saves
objects in a paper range. But, this parameter will save objects out pf the paper range.
Example
/rxlsfullhorz [1]
164
Appendix III. Report Designer Parameters
3.1.109. /rxlsnopb
Instruction
/rxlsnopb
Description
It controls not to put page separator line when you save in excel file.
Example
/rxlsnopb
3.1.110. /rxlsopt
Instruction
Description
When you save a report as a excel file, it sets ‘Keep the report format’. It also controls dialog
box saying ‘Excel Option’ not to appear on a screen. .
0 : ‘Excel Option’ dialog box will be presented. Remaining report form will decided depending
on user’s choice. (default value)
1 : It saves as it remain a report format. ‘Excel Option’ dialog box will not appear.
2 : It does not keep a report format as it saves. ‘Excel Option’ dialog box will not appear.
cf. If you select ‘View As MS-Excel’ in viewer tool bar, ‘Excel Option’ dialog box will not
appear.
Example
/rxlsopt [1]
/rxlsopt [2]
165