Vous êtes sur la page 1sur 2

DISEÑO DE MURO DE CONTENCION

gc°c°= 2.30 ton/m3


gs = 1.82 ton/m3
f= 32.00 °
f'c = 2.10 Kg/cm2
st = 0.92 Kg/cm2
FSD = 1.50
FSV = 1.75

f = 32º VACIADO IN SITU

f=tgf = 0.625

Usar f = 0.6 para cálculo de la estabilidad


contra deslizamiento

CALCULO DE ENPUJE ACTIVO

Ka = tg2 (45º-f/2) = 0.307

2.- PREDIMENSIONAMIENTO
H = 3.50 m
B = 0.5H = 1.75 a B = 0.75H = 2.63

Consideramos: B = 2.00 m

t ≥ 0.30m

Consideramos: t = 0.30 m

3.- VERIFICACION DE ESTABILIDAD


P = 0.5 Ka gs H2 = 3.43 Ton/m

H/3 = 1.17 m

Pi N = Pesos (Ton/m) X=Brazo de giro (m) Mr =N*X (Ton)


P1 2.30 1.00 2.30
P2 2.07 0.45 0.93
P3 3.16 0.97 3.06
P4 1.00 1.15 1.15
P5 2.50 1.33 3.34
Total 11.04 10.78

FSD = Hr / P = f N / P

FSD = 1.93 > 1.5 OK

FSV = Mr / Ma = Mr / (P*H/3)

FSV = 2.70 > 1.75 OK

4.- PRESIONES SOBRE EL TERRENO


Xo = (Mr - Ma)/N

Xo = 0.61 m

e = B/2 - Xo

e = 0.39 m

B/6 = 0.33 m

Por lo tanto: e < B/6 ok

q1 = N(1+ 6e/B)/B

q1 = 11.90 Ton/m2

q2 = N(1- 6e/B)/B

q2 = -0.87 Ton/m2

Por lo tanto: (q2)/3 < st 0o