Vous êtes sur la page 1sur 1

AS5100.

6 Appendix B - Strength of Stiffened Web Panels Under Combined Actions


Max moment + corresponding shear and torsion

B1 - Yielding Check

fy 340 MPa
dp 2290 mm
tw 20 mm
s 250 mm
bbf 275 mm
R*w 2551 kN
N*w 0 kN
M* 31664 kNm Conservative as can take all load through flange only therefore no interaction.
% taken by web 16.0 % % of capacity contribution from web
M*w 2533 kNm
V*w 993 kN

Aw 45800 mm2
Zwe 1.75E+07 mm3
f*w 112 MPa
Φ 0.9

= 265506 - 63884 + 15371 + 1613 <= 115600


218607 <= 115600 NOT OK
Ratio 0.53
B2 - Buckling Check

Now 5248 kN
Vv 9343 kN
αw 22.37
de 67 mm
βw 5.19
Rsb 9705 kN
Mw 5943 kNm

= 0.292 + 0.000 + 0.014 + 0.22 <= 1


0.53 <= 1 OK
Ratio 1.89