Vous êtes sur la page 1sur 1

Drainage Design

Building Data STD DOWN TAKE PIPES


Roof Slope = 1.00 : 10 Downspout Area (mm2)
Roof Angle = 5.71 Deg. 1 x Metal 12462
Width of roof to be drained (Left) = 31.25 m 102.53 ft 1 x 150 Ф 17671
Width of roof to be drained (Right) = 0.00 m 0.00 ft 1 x 200 Ф 31416
Total width to be drained ( R ) = 31.41 m 103.04 ft 1 x 250 Ф 49087
Column Spacing = 10.00 m 32.81 ft 2 x Metal 24924
2 x 150 Ф 35343
Rainfall Data
Rainfall intensity ( I ) = 150 mm / hr 5.906 inches / hr STD GUTTER
Average Depth
Type
Gutter & Downspout Selection Width(mm) (mm)
Gutter selection = G-1 EG 175 145
Downspout selection = 1 x 150 Ф G-1 540 165
G-2 455 215
Gutter Depth ( d ) = 165 mm 6.50 in G-3 370 165
Average gutter width ( w ) = 540 mm 21.26 in G-4 300 215
Downspout area ( A ) = 17671 mm2 27.39 in2 Refer to the sketch for the detail of gutter &
Downspout location = EXTERIOR down take pipes.
T= 1.00 Depth = Gutter Depth - 25mm free board

EG - Eave Gutter Metal Pipe G1 - Internal Gutter G2 - Internal Gutter G3 - Internal Gutter G4 - Internal Gutter

For Exterior usage Type-1 Type-2 Type-3 Type-3


Down spout location = EXTERIOR gutters for Interior drainage and downspout location to be selected as 'INTERIOR'

MBMA Equation :

Required Downspout Spacing 'L'

(a) Based on Gutter Capacity 15.59 m 51.15 ft

(b) Based on Downspout Capacity


Downspout Spacing 'L' = 1200 x A / ( I x R )
Downspout Spacing 'L' = 16.46 m 54.01731 ft

Provide 1 x 150 Ф Downspout @ 10.00 m spacing

Reference: MBMA 2006 Appendix 'A' Section A4 page XI-A4-1