Warning
POSITIVE BUOYANCY
ALWAYS ATTACH THE LANYARD
❶
REGISTER YOUR PRODUCTS
TO ACTIVE WARRANTY
Deteknix Scuba Tector provides a limited warranty
to the original purchaser of its products against all
Snorkeling mode(0~10M depth) defects in original workmanship and material,
under normal use and service, for one year from
Power on/off (default)
the date of purchase with the following exceptions:
❸ Press the Power button once to power on. Press
• All warranties void if electronic part opened.
❹ again to power off.
• Batteries are warranted for 90 days.
❺ Power on/off (retune on) • Cosmetic discoloration of surfaces.
❻
Press the Power button once to power on. Press 1S • Water flooding caused from battery cap seal.
❼ to power off. Deteknix will not be liable for any further loss,
damages, or expenses, including incidental or
❽ consequential damages directly or indirectly
❾ arising from the sale or use of this product.
2
DO & DON’T
• Always make sure battery cap is tightened before
❶ Detection coil 1 entering the water. Only open battery cap with
❷ Effective area clean hand.
❸ Flashlight LED • Always store your detector fully charged.
❹ Indication LED • Always rinse equipment in fresh water after
every dive.
❺ Buzzer
• Always apply silicone grease after cleaning O-
❻ Power Dive mode (10~60M,read P12 for detail) ring.
❼ Mode Hold two buttons for 2sec to enter dive mode. The • Only open battery cap by clean hand.
❽ Battery cover red light will flash 5 times and vibration will start. • Never leave your equipment in the rinse bucket.
❾ Anchor loop Click mode 3 times quickly to switch back to shallow It may be damaged by other equipment.
water mode.
SENSITIVITY ALARM PROGRAMING
❹
❸
❷
❶
4sec
When powered on, keep pressing Mode button When powered on, press Mode button quickly to While powered on, keep pressing on Mode button
and quickly press power button to change switch through the three different alarm modes for 4 seconds to enter LED light control
sensitivity level from 1~4(highest level) . Each (Beep, Vibration only, Beep and Vibrate) programing. While indicator and flashlight both
level will sound an extra beep until level 4 Losing mode. The probe will start to beep at light up, quick press on mode button to switch
which will sound a long beep. certain frequency when no alarm or operating from four modes(indicator only, flash light only,
for 3 minutes. This is to remind the user to power all off, all on)
off or to pick up and re-use. Turn on/off tuning function. Under Expert Mode,
Power saving mode. The probe will turnoff quick press power button once to activate/de-
automatically after 3 minutes alarming under activate the retune function.
losing mode to save battery.
RETRIEVE LOW BAT. RECHARGING
Low battery
When the probes flash light start
to blink at a certain frequency, it
means it needs recharging. You
can still use it but the sensitivity
$ will be a little lower.
$
Scanning Pinpointing
keep 5sec~
Deactivate:Keep the coil up for 5
seconds to turn back to no standby
Apply quality silicone O-ring grease mode (DMS). The red indication will
The device is waterproof to 60M/200FT. It can
thoroughly. blink once every 3 sec. The unit is
withstand immersion in 60M/200FT of water still powered on until power off at
for 30 minutes. After submersion, be certain to snorkeling mode.
wipe dry and air dry the device before using or
charging.
Notice:
Do not store the device where prolonged
Under deep water when two buttons
exposure to extreme temperatures can occur
been pressed down, the detector will
because it can cause permanent damage. Change O-ring once a year at least. Use switch to dive mode automatically.
qualified original part only.