Vous êtes sur la page 1sur 2

Specification

(Subject to change without further notice!)

Portable VLF cable test set with 0.1 Hz - technology


The portable cable test set KPG 40kV VLF is used for testing of medium voltage cables in accordance to the
standards CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.
The test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.
VLF Test enables detection of damages of the insulation within shortest test time. The KPG 40kV VLF can test
cables with extruded insulation (XLPE-, PE-, EPR-insulation) as well as cables with paper-oil insulation (PILC).
Cable sheath testing with direct voltage is also possible.

KPG 40kV VLF


Power supply 230 V (± 10%), 10 A, 50/60 Hz
Output voltage 0...40 kVr.m.s. , 0.1 Hz VLF (0.02 Hz optional)
± 0...57 kV DC

Voltage waveshapes VLF similar sine-wave (true R.M.S. measurement) & Direct voltage
max. load (VLF) 3.7 µF at 19 kVr.m.s. , 0.1 Hz (app. 10 km XLPE-cable 11kV/150mm²)
12.3 µF at 19 kVr.m.s. , 0.02 Hz (app. 34 km XLPE-cable 11kV/150mm²)
1.8 µF at 38 kVr.m.s. , 0.1 Hz (app. 8 km XLPE-cable 22kV/150mm²)
6.0 µF at 38 kVr.m.s. , 0.02 Hz (app. 25 km XLPE-cable 22kV/150mm²)
Overcurrent trip (DC) 10 mA
Discharge integrated automatic discharge device
9000J (up to 6 µF at 55kV)
Voltage measuring range -60 ... 0 ... 60 kV
Current measuring ranges ± 0 ... 100 µA / 1 mA / 10 mA
Operating temperature -20 ... +50°C
Construction in two parts, Operation unit and High Voltage unit
Weight Operation unit 17 kg
HV unit 49 kg
Dimensions (W x H x D)
Operation unit 37 x 34 x 20 cm
HV unit 40 x 44 x 24 cm

Characteristics: Scope of supply:


1 Compact portable VLF test device 1 Operation unit with protective bag and cable storage
1 Easily portable from 1-2 person 1 High Voltage unit
1 Simple operation 1 HV-connecting cable (shielded), standard length 5m
1 Menue-assisted control 1 Connecting cable, HV unit to Operator unit, length 3m
1 Fully automatic test sequence 1 Ground cables
1 Integrated timer with automatic tripping 1 User manual
1 Integrated breakdown detection
1 Integrated fault time detection
Options:
1 Voltage measurement direct at HV output
1 Protective ground circuit 1 Datalogging (USB) for VLF test sets
1 Protective circuit / indication in accord. with VDE 0104 1 Frequency extension: 0.05 or 0.02 Hz
1 Leakage current measurement during VLF test 1 Transport case

MADE IN GERMANY 1234351623

Kilovolt Prueftechnik Chemnitz GmbH 1 Annaberger Str. 73 1 09111 Chemnitz 1 Germany


Tel.: +49 371 53032-10 1 Fax: +49 371 53032-11
eMail: sales@kilovolt.biz 1 Internet: www.kilovolt.biz