Académique Documents
Professionnel Documents
Culture Documents
Application
Cables are double insulated, electron-beam cross-linked cables for Photovoltaic power applications.
Construction
Tinned Fine copper strands, acc. to EN 60228 ,class 5.
Electron-beam cross-linked polyolefin insulation, white in color, 120o C
Electron-beam cross-linked polyolefin sheath, Black/Red/Blue
Technical data
Rated voltage: 600 / 1000V (DC1800V)
Max. Conductor Temp. 120 o C
Ambient Temp. > 25 years (TÜV): 40 o C to +90o C
Max. short circuit temp. (5 sec.) : 200 °C
Bending radius: 5 X Ø ( min. bending radius )
Approval standard: 2 PfG 1169/08.2007 (PV1-F)
Dimensions
Nominal Max.
Outer
Cross Cable Conductor
diaeter
sectional Weight DC
approx.
area of Resistance
conductor at 20o C
mm2 Mm kg /km
2.5 5.0 43.7 8.21
4.0 5.4 60.0 5.09
6.0 6.7 81.0 3.39
10 8.4 126.7 1.95
16 9.5 194.0 1.24
25 10.9 276.0 0.795
Groups
For groups reduction factors according to IEC 60364-5-52, Table A.52-17 shall apply.