Vous êtes sur la page 1sur 3

600/1000V 120oC SOLAR PV1-F

Halogen Free PV Cables

Application
Cables are double insulated, electron-beam cross-linked cables for Photovoltaic power applications.

Construction
Tinned Fine copper strands, acc. to EN 60228 ,class 5.
Electron-beam cross-linked polyolefin insulation, white in color, 120o C
Electron-beam cross-linked polyolefin sheath, Black/Red/Blue

Technical data
Rated voltage: 600 / 1000V (DC1800V)
Max. Conductor Temp. 120 o C
Ambient Temp. > 25 years (TÜV): 40 o C to +90o C
Max. short circuit temp. (5 sec.) : 200 °C
Bending radius: 5 X Ø ( min. bending radius )
Approval standard: 2 PfG 1169/08.2007 (PV1-F)

Schedule of Guarantee Test


1) Resistance of conductor: acc. to EN 50395
2) Voltage Test on completed cable: acc. to EN 50395
AC-Test-Voltage : 6500V
DC-Test-Voltage : 1500V
3) Surface Resistance of Sheath : acc. to EN 50395
4) Insulation Resistance : acc. to EN 50395
5) Long term resistance to DC : acc. to 2 PfG 1169/08.2007 Annex D
6) Construction & Dimensional test
(for Insulation & sheath) : acc. to EN 50396
7) Pressure Test at high Temp. : acc. to EN60811-3-1
8) Damp Heat Test : acc. to EN 60068-2-78
9) Acid & Alkaline Resistance : acc. to EN 60811-2-1
10) Mechanical Test for Insulation & Sheath
Tensile strength Test: acc. to EN 60811-1-1/2
Elongation Test: acc. to EN 60811-1-1/2
Hot Set Test : acc. to EN 60811-2-1
Thermal Endurance: acc. to EN 60216-2
11) Cold Impact Test (-40o C): acc. toEN 60811-1-4 & 2 PfG 1169/08.2007 Annex E
12) Ozne Resistance: acc. to EN 50396
13) Weathering / UV-Resistance: acc. to HD 605/A1
14) Dynamic Penetration Test: acc. to 2 PfG 1169/08.2007 Annex F
15) Notch Propagation : acc. to 2 PfG 1169/08.2007 Annex G
16) Shrinkage Test: acc. to EN 60811-1-3
17) Flame Propagation Test : acc. to EN 60322-1-2
18) Halogen Test: acc. to 2 PfG 1169/08.2007 Annex B
acc. to EN 50267-2-1/2
acc. to 2 PfG 1169/08.2007 Annex C
1
SOLAR PV1-F 120oC
Halogen Free PV Cables

Dimensions
Nominal Max.
Outer
Cross Cable Conductor
diaeter
sectional Weight DC
approx.
area of Resistance
conductor at 20o C
mm2 Mm kg /km
2.5 5.0 43.7 8.21
4.0 5.4 60.0 5.09
6.0 6.7 81.0 3.39
10 8.4 126.7 1.95
16 9.5 194.0 1.24
25 10.9 276.0 0.795

Current carrying capacity


Ambient temperature: 60 °C
Max. conductor temperature: 120 °C

Current carrying capacity of PV-cables


Nominal cross Current carrying capacity according to method of installation
sectional area Single cable free in air Single cable on a Two loaded cables
surface touching, on a surface
mm2 A A A
2.5 41 39 33
4.0 55 52 44
6.0 70 67 57
10 98 93 79
16 132 125 107
25 176 167 142

Conversion factor for deviating temperatures


Ambient temperature Conversion factor
°C
bis 60 1.00
70 0.91
80 0.82
90 0.71
100 0.58
110 0.41

Groups
For groups reduction factors according to IEC 60364-5-52, Table A.52-17 shall apply.