PROJECT NUMBER: TAG NO.

:
CLIENT: JOB NUMBER:
MODEL: SERIAL NO.: MFR No.:

ELECTRICAL GENERATOR SPECIFICATION:


EQUIPMENT NO.:
APPLICABLE TO: 9 PROPOSAL 9 PURCHASE 9 AS BUILT
INFORMATION TO BE COMPLETED BY: 9 PURCHASER 9 VENDOR

m SITE CONDITIONS ENGINE

Location: 9 Indoors 9 Outdoors Type: 9 Diesel 9 Crude 9 Natural Gas


9 Self Contained Building
9 Ambient Air Temp: Max ºC Min ºC Diesel Fuel:
9 Air temp at engine intake: ºC Max 9 Diesel No. 1 9 Diesel No. 2 (Standard in Canada)
9 Altitude: m. above sea Natural Gas Fuel:
Supply Pressure: kPag
Min heat value: ML/m3
9 Fuel gas analysis attached

Speed Standby Power: 9 rpm


Speed Prime Power: 9 rpm
SYSTEM
Cooling:
Duty: 9 Prime Power 9 Standby Power 9 Vendors Choice 9 Set mounted radiator

Output Rating: 9 kW 9 Set mounted radiator extended skid


p.f. 9 0.8 Leading 9 0.8 Lagging 9 Remote mounted Radiator 9 Other:
Voltage Regulator:
9 ± 1% per standard 9 1.0 9 Other Coolant:
9 50/50 glycol water

Frequency Regulation: Starter:


9 Isochronous per standard 9 ± 3% drop 9 Electric 9 Air
9 Pneumatic 9 Natural Gas

Min. supply press. kPag


Largest motor to be started:
9 h.p. Starter Compressor: 9 Diesel 9 Gas
9 Electric

Optional Engine shut downs/alarms


SD Alarm
9 Vibration high (engine) 9 9
9 Oil level low 9 9
9 Vibration high (cooler) 9 9
9 Coolant level low 9 9
9 Oil temperature high 9 9
9 Exhaust temperature high 9 9
9 Bearing temperature high 9 9

REV DESCRIPTION DATE BY CH APP REV DESCRIPTION DATE BY CH APP

file:///conversion/tmp/scratch/384893432.xlsx Page 1 of 8
file:///conversion/tmp/scratch/384893432.xlsx Page 2 of 8
ELECTRICAL GENERATOR NOTE: INFORMATION TO BE COMPLETED BY: m PURCHASER o VENDOR
GENERATOR CONTROL POWER

9 Ratings: Voltage V Phase 9 Supplied by others: VDC


9 Frequency Hz
9
Insulation:
OPERATION
9 Class H per standard
9 Other: Parallel Operation:

Rated temperature rise: 9 Not required


9 Parallel with utility
9 Class B (80ºC) over 40ºC Utility fault level:
9 Class F (105ºC) over 40ºC 9 Parallel with other generators
9 Other: 9 Isochronous 9 Droop
Synchronizing:
Winding:
9 Manual synchronizing
9 4 wire wye 9 Automatic
9 Other: 9 Syncroscope

Winding temperature:
9 Interconnection to the Utility:
9 RTD 100 Ohm pt. per phase
9 Thermistors: per phase CONTROL PANEL TYPE
9 Other:
9 Engine - Generator controls in common panel
Current Boost:
9 Wall mount 9 Free standing
9 Required per standard 300% of rated current
9 Not required 9 Engine - generator controls in separate panels
9 Other:
Engine panel:
Space heater: 9 Wall mount 9 Free standing

9 Required: Generator Panel:


9 W V 9 Wall mount 9 Free standing
9 Not required
9 Mfg. Standard
Generator Enclosure:

9 ODP guarded standard


9 TEFC
9 Other:

REV DESCRIPTION DATE BY CH APP REV DESCRIPTION DATE BY CH APP

file:///conversion/tmp/scratch/384893432.xlsx Page 3 of 8
file:///conversion/tmp/scratch/384893432.xlsx Page 4 of 8
ELECTRICAL GENERATOR NOTE: INFORMATION TO BE COMPLETED BY: m PURCHASER o VENDOR
GENERATOR MONITORING & CONTROL TESTS

Control panel devices: 9 Standard

9 Voltmeter c/w phase selector switch 9 Witness


9 Ammeter c/w phase selector switch
9 Frequency meter
9 Run time meter
9 Winding temperature indicator
9 Voltage adjust rheostat

Protective controls: MISCELLANEOUS

9 High winding temperature Silencer:


9 Alarm ºC 9 Residential per standard
9 Shutdown ºC 9 Other:
9 Over voltage
9 Under frequency Location:
9 Other
9 Inside generator building
Excitation support system: See 7.7 9 Outside generator building

9 300% rated current for 10 Sec. Fuel Tank (diesel):


9 Other:
9 Day L run time hr
Circuit breaker: 9 Main L run time hr
9 Required 9 Not required
Motor stators for auxiliary equipment:
Type Size
9 By others standard
Transfer Switch: 9 By Vendor

9 Required 9 Not Required GENERATOR


9 By Others 9 By Vendor
Mfg.:

Model:

Rated kW @ p.f.

Rated kVA:

PMG 9 Yes 9 No

Reactances: Xd

X'd

X"d

Winding Pitch:

REV DESCRIPTION DATE BY CH APP REV DESCRIPTION DATE BY CH APP

file:///conversion/tmp/scratch/384893432.xlsx Page 5 of 8
file:///conversion/tmp/scratch/384893432.xlsx Page 6 of 8
ELECTRICAL GENERATOR NOTE: INFORMATION TO BE COMPLETED BY: m PURCHASER o VENDOR

ENGINE GENERATOR CONTROLS

Mfg.: Engine governor:


Model: Mfg.:
Cycle:
Model:
Aspiration: 9 Natural 9 Turbo-charged
Voltage regulator:
Rated power at site: kW Mfg.
No. of cylinders:
Bore mm Model:
Stoke mm
Displacement L COOLING SYSTEM
Compression ratio

STARTING Radiator Mounting:

9 Electric Fan: 9 Motor driven 9 Shaft driven

No. of batteries Radiator air flow: L/min.


Type of batteries
Make and manufacturer Engine coolant capacity L
Battery rating cranking A
Voltage FUEL

9 Charger Consumption at rated load specified altitude, ambient temp and fuel
gas being used
Type:
Mfg.: OTHER INFORMATION
Model:
Rating:

9 Output alarm contact

9 Pneumatic

Volume per crank cycle m³


Starter manufacturer

Volume bottle required 9 Yes 9 No

REV DESCRIPTION DATE BY CH APP REV DESCRIPTION DATE BY CH APP

file:///conversion/tmp/scratch/384893432.xlsx Page 7 of 8
file:///conversion/tmp/scratch/384893432.xlsx Page 8 of 8