Input data for earthquake load

calculation Unit

Seismic Zone Factor Z 1

Importance Factor I 1

Structural Performance Factor K 1

Height of the Building H 12.19 m

Dimension of Building along X -direction Dx 12.19 m

Dimension of Building along Y -direction Dy 6.4 m

Time Period of Building along X -direction Tx 0.3142 Sec.

Time Period of Building along Y -direction Ty 0.4337 Sec.


Soil Type Medium Type Type II
Basic Seismic Coefficient along X-
direction Cx 0.08
Basic Seismic Coefficient along Y-
direction Cy 0.08
Design horizontal seismic coefficient
along X-direction Cdx= CxZIK 0.08
Design horizontal seismic coefficient
along Y-direction Cdy=CyZIK 0.08
Total Seismic Weight of the
Building(DL+0.25LL) W 2758.425 KN

Total Base Shear(Vb) along X-direction Vbx 220.674 KN

Total Base Shear(Vb) along Y-direction Vby 220.674 KN


Maximum Drift Ratio 0.000728

Maximum Displacement at top storey 14.1066 mm


NB - 105
Clause8.1.6, figure 8.2,
Pokhara
Clause8.1.7, table 8.1, other
structures
Clause 8.1.8, table 8.2,
Ductile moment resisting
Frame
Three storey building with
stair cover

Clause 7.3

Clause 7.3
Clause 8.1.5

Clause 8.1.4, Figure-8.1 u1 14.1066 2.218

Clause 8.1.4, Figure-8.1 u1 11.8886

Clause 8.1.1 u1

Clause 8.1.1 u1

Clause 10.1.1

Clause 10.2.1

Clause 10.2.1 Ht. of building in mm 3048.78


0.0015< 0.004
GF FF Mumty 12 16 20
800 720
794 732
772 720
783
849 740 113.04 200.96 314
1439 1070 729 C3 C2 4 452.16 803.84 1256
1483 1156 743 C3 C2 8 904.32 1607.68 2512
804 720
801 720 4-16,4-12 1256
915 725 8-12, 904.32
1305 804 720 C3
1490 876 720 C3 4-20,4-16 2059.84
910 720
C3 1607 8-16,
C2 1256 4-16,4-12
C1 904 8-12,