Dimension of Building along X -direction Dx 12.19 m
Dimension of Building along Y -direction Dy 6.4 m
Time Period of Building along X -direction Tx 0.3142 Sec.
Time Period of Building along Y -direction Ty 0.4337 Sec.
Soil Type Medium Type Type II Basic Seismic Coefficient along X- direction Cx 0.08 Basic Seismic Coefficient along Y- direction Cy 0.08 Design horizontal seismic coefficient along X-direction Cdx= CxZIK 0.08 Design horizontal seismic coefficient along Y-direction Cdy=CyZIK 0.08 Total Seismic Weight of the Building(DL+0.25LL) W 2758.425 KN
Total Base Shear(Vb) along X-direction Vbx 220.674 KN
Total Base Shear(Vb) along Y-direction Vby 220.674 KN
Maximum Drift Ratio 0.000728
Maximum Displacement at top storey 14.1066 mm
NB - 105 Clause8.1.6, figure 8.2, Pokhara Clause8.1.7, table 8.1, other structures Clause 8.1.8, table 8.2, Ductile moment resisting Frame Three storey building with stair cover