AdditionReportingI Parameters range
nterval of FMCS, AdditionWindow, is
AdditionTime of AdditionTime, relative
Active Set Weighting Coefficient (W) FMCS, AdditionReportingInterv to the
is used to weight either the AdditionWindow of al and measur
measurement result of the best active FMCS, DropTime MaxActiveSetSize are ement
set cell (M_best) or the sum of Handover of FMCS, used in case of event result
measurement results of all active set Control, DropWindow of 1A. Parameters of the
Active Set ActiveSet cells (M_sum) when the UE Mobile FMCS, DropWindow and best
Weighting Weighting calculates the reporting range for the Device MaxActiveSetSize DropTime are used in 0...2, step active
Coefficient Coefficient W events 1A (cell Control of FMCS case of event 1B. 0.1 0 set cell
No
periodical
reporting
(0), 0.25
ActiveSetWeighting s. Not
When a monitored cell enters the Coefficient of Parameters allowed
reporting range and triggers event 1A FMCS, AdditionWindow, (1), 0.5 s
(cell addition), the UE transmits a AdditionTime of AdditionTime, (2), 1 s
Measurement Report to the RNC. If Handover FMCS, ActiveSetWeightingCoe (3), 2 s
the RNC is not able to add the Control, AdditionWindow of fficient and (4), 4 s
Addition AdditionR Reporti monitored cell to the active set, the Mobile FMCS, MaxActiveSetSize are (5), 8 s
Reporting eportingInt ng UE continues reporting after the initial Device MaxActiveSetSize used in case of event (6), 16 s 0.5 s
Interval erval interval repo Control of FMCS 1A. (7) (2)
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9),
ActiveSetWeighting Parameters 240 ms
When a monitored cell enters the Coefficient of ActiveSetWeightingCoe (10), 320
reporting range (addition window), FMCS, fficient, ms (11),
the cell must continuously stay within AdditionReportingI AdditionWindow, 640 ms
the reporting range for a given period Mobile nterval of FMCS, AdditionReportingInterv (12), 1280
of time before the UE can send a Device AdditionWindow of al and ms (13),
Time Measurement Report to the RNC in Control, FMCS, MaxActiveSetSize are 2560 ms
Addition AdditionTi to order to add the cell into the active Handover MaxActiveSetSize used in case of event (14), 5000 100
Time me trigger set ( Control of FMCS 1A. ms (15) ms (6)
Old
default
value
(2.5
dB) will
cause
less
SHO
overhe
ad,
which
is
good,
but to
avoid
active
set
update
s due
to
possibl
e rapid
change
ActiveSetWeighting s in
Addition Window determines the Coefficient of Parameters radio
relative threshold (A_Win) used by FMCS, ActiveSetWeightingCoe environ
the UE to calculate the reporting AdditionReportingI fficient, AdditionTime, ment
range of event 1A. The threshold is Handover nterval of FMCS, AdditionReportingInterv the
either relative to the CPICH Ec/No Control, AdditionTime of al and value 4
Reporti measurement result of the best active Mobile FMCS, MaxActiveSetSize are 0...14.5 dB is
Addition AdditionW ng set cell (M_best), or to the sum of Device MaxActiveSetSize used in case of event dB, step set as
Window indow Range active set Control of FMCS 1A. 0.5 dB 4 dB default.
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9),
240 ms
When an active set cell leaves the (10), 320
reporting range (drop window), the ms (11),
cell must continuously stay outside 640 ms
the reporting range for a given period Mobile ActiveSetWeighting Parameters (12), 1280
of time before the UE can send a Device Coefficient of DropWindow and ms (13),
Time Measurement Report to the RNC in Control, FMCS, ActiveSetWeightingCoe 2560 ms 640
to order to remove the cell from the Handover DropWindow of fficient are used in case (14), 5000 ms
Drop Time DropTime trigger active set Control FMCS of event 1B. ms (15) (12)
With 4
dB
‘Additio
n
window
’ 6 dB
should
be
used
here.
With
2.5 dB
Drop Window determines the relative ‘Additio
threshold (D_Win) which is used by n
the UE to calculate the reporting window
range of event 1B. The threshold is Handover Parameters ’ 4 dB
either relative to the CPICH Ec/No Control, ActiveSetWeighting DropWindow and should
Reporti measurement result of the best active Mobile Coefficient of ActiveSetWeightingCoe 0...14.5 be
Drop DropWind ng set cell (M_best) or to the sum of Device FMCS, DropTime fficient are used in case dB, step used
Window ow Range active Control of FMCS of event 1B. 0.5 dB 6 dB here.
This parameter should
have at least 2 dB
lower value than
defined in
EDCHRemEcNoOffset
to avoid frequent
When E-DCH channel type is going channel type switches HSUPA
to be selected, the RNC checks between DCH and E- (option
downlink CPICH Ec/No values of DCH. This shall be al) AND
cells, which are in DCH active set but checked by the system. HSUPA
not in E-DCH active set. If CPICH DropWindow of If the usage of E-DCH Handov
Allow E- EDCHAdd Ec/No of any of those cells is better FMCS, is wanted to be limited -10...6 dB, ers
DCH usage EcNoOffs than CPICH Ec/No of serving cell Handover EDCHRemEcNoOff for the case where step 0.5 (option
EcNo offset et plus the offset Control set of FMCS DCH dB 0 dB al)
RLMeasRepPeriod
defines the
This parameter determines the measurement report HSUPA
number of event triggered periodic period. (option
intra-frequency measurement reports EDCHEcNoOffsetBran al) AND
CPICH from which the RNC calculates the RLMeasRepPeriod chAddFail is the HSUPA
EcNo averaged CPICH Ec/No values. This of WBTS, parameter which is 1...32 Handov
averaging EDCHEcN value is used to evaluate if E-DCH EDCHEcNoOffsetB used when evaluating MeasRep, 3 ers
window for oAveragin usage can continue in the case of Handover ranchAddFail of the averaged CPICH step 1 Meas (option
E-DCH gWindow branch addition f Control FMCS Ec/No values. MeasRep Rep - al)
This parameter determines the HSUPA
maximum allowed difference between (option
the averaged CPICH Ec/No of the al) AND
CPICH neighbouring cell and the averaged EDCHEcNoAveraging HSUPA
EcNo offset EDCHEcN CPICH Ec/No of the serving E-DCH Window defines the Handov
in E-DCH oOffsetBr cell in situations when the RNC is not EDCHEcNoAveragi averaging window used -10...6 dB, ers
for branch anchAddF able to perform a soft handover Handover ngWindow of for CPICH Ec/No step 0.5 (option
addition fail ail - between these cells Control FMCS measurements. dB 0 dB - al)
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9),
240 ms
If the inter-frequency or inter-RAT (10), 320
(GSM) handover caused by low ms (11),
measured absolute CPICH Ec/No is GSMcauseCPICHE 640 ms
enabled, the RNC starts the inter- cNo of FMCG, (12), 1280
CPICH frequency or GSM measurement in IFHOcauseCPICH ms (13),
Ec/No HHO HHoEcNo Time compressed mode when all active set EcNo of FMCI, 2560 ms 1280
Cancellation CancelTim to cells have triggered the reporting Handover HHoEcNoCancel of (14), 5000 ms
Time e trigger event 1F for CPICH E Control FMCS ms (15) (13)
Relativ
ely high
value
needed
If the inter-frequency or inter-RAT GSMcauseCPICHE in order
(GSM) handover caused by low cNo of FMCG, to have
measured absolute CPICH Ec/No is IFHOcauseCPICH succes
Thresh enabled, the UE transmits an event EcNo of FMCI, The value of sful CM
old 1F triggered measurement report to HHoEcNoCancel of HHoEcNoThreshold measur
CPICH used the RNC when the CPICH Ec/No FMCS, must be lower than the ements
Ec/No HHO HHoEcNo freque measurement result of an active set Handover HHoEcNoTimeHyst value of -24...0 dB, -12 &
Threshold Threshold ncy cell becomes worse tha Control eresis of FMCS HHoEcNoCancel. step 1 dB dB ISHO.
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9), Relativ
240 ms ely fast
If the inter-frequency or inter-RAT (10), 320 reportin
(GSM) handover caused by low ms (11), g after
measured absolute CPICH Ec/No is GSMcauseCPICHE 640 ms triggeri
enabled, the UE transmits an event cNo of FMCG, (12), 1280 ng
CPICH 1F triggered measurement report to IFHOcauseCPICH ms (13), works
Ec/No HHO HHoEcNo Time the RNC when the CPICH Ec/No EcNo of FMCI, 2560 ms better
Time TimeHyste to measurement result of an active set Handover HHoEcNoThreshol (14), 5000 100 with
Hysteresis resis trigger cell becomes worse tha Control d of FMCS ms (15) ms (6) UE.
3dB
differen
ce is
If the inter-frequency or inter-RAT GSMcauseCPICHr needed
(GSM) handover caused by low scp of FMCG, betwee
measured absolute CPICH RSCP is IFHOcauseCPICHr n
Thresh enabled, the RNC starts the inter- scp of FMCI, The value of trigger
old frequency or GSM measurement in HHoRscpCancelTi HHoRscpCancel must and
CPICH used compressed mode when all active set me of FMCS, be higher than the -115...-25 cancel
RSCP HHO HHoRscp freque cells have triggered the reporting Handover HHoRscpThreshold value of dBm, step -102 parame
Cancellation Cancel ncy event 1F for CPICH RS Control of FMCS HHoRscpThreshold. 1 dBm dBm ters.
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9),
240 ms
If the inter-frequency or inter-RAT (10), 320
(GSM) handover caused by low ms (11),
measured absolute CPICH RSCP is GSMcauseCPICHr 640 ms
enabled, the RNC starts the inter- scp of FMCG, (12), 1280
CPICH frequency or GSM measurement in IFHOcauseCPICHr ms (13),
RSCP HHO HHoRscp Time compressed mode when all active set scp of FMCI, 2560 ms 1280
Cancellation CancelTim to cells have triggered the reporting Handover HHoRscpCancel of (14), 5000 ms
Time e trigger event 1F for CPICH RS Control FMCS ms (15) (13)
Filtering
period of
200 ms
(0),
Filtering
period
approxima
tes 300
ms (1),
Filtering
period
approxima
tes 400
ms (2),
Filtering
period
approxima
tes 600
ms (3),
Filtering
period
approxima
tes 800
In the CELL_DCH state the UE ms (4),
physical layer measurement period Filtering
for intra-frequency CPICH RSCP period
measurements is 200 ms. The Filter approxima Filteri Higher
CPICH Coefficient parameter controls the tes 1100 ng layer
RSCP HHO HHoRscp Filter higher layer filtering of physical layer ms (5), period filtering
Filter FilterCoeff coeffici CPICH RSCP measurements before Filtering of 200 is not
Coefficient icient ent the event evaluatio pe ms (0) used
If the inter-frequency or inter-RAT GSMcauseCPICHr This
(GSM) handover caused by a low scp of FMCG, should
measured CPICH RSCP is enabled, IFHOcauseCPICHr be 2..3
Thresh the UE transmits an event 1F scp of FMCI, The value of dB
old triggered measurement report to the HHoRscpCancel of HHoRscpThreshold below
CPICH used RNC when the CPICH RSCP FMCS, must be lower than the -115...-25 the
RSCP HHO HHoRscp freque measurement result of an active set Handover HHoRscpTimeHyst value of dBm, step -105 HHO
Threshold Threshold ncy cell becomes worse than or equa Control eresis of FMCS HHoRscpCancel. 1 dBm dBm Cancel.
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9), Relativ
240 ms ely fast
If the inter-frequency or inter-RAT (10), 320 reportin
(GSM) handover caused by low ms (11), g after
measured CPICH RSCP is enabled, GSMcauseCPICHr 640 ms triggeri
the UE transmits an event 1F scp of FMCG, (12), 1280 ng
CPICH triggered measurement report to the IFHOcauseCPICHr ms (13), works
RSCP HHO HHoRscp Time RNC when the CPICH RSCP scp of FMCI, 2560 ms better
Time TimeHyste to measurement result of an active set Handover HHoRscpThreshold (14), 5000 100 with
Hysteresis resis trigger cell becomes worse than the thres Control of FMCS ms (15) ms (6) UE.
IMSI
based
The parameter indicates whether the intra-
IMSI based intra-frequency handover frequen
is allowed in the cell. The alternative cy IMSI
values of the parameter are the Not handov Based
following: 0: IMSI based intra- allowed er is Handov
frequency handover is not allowed. 1: (0), Not not er
IMSI Based IMSIbase IMSI based intra-frequency handover Handover Allowed allowe allowed (option
SHO dSHO is all Control (1) d (0) . al)
ActiveSetWeighting
Coefficient of Parameters
FMCS, AdditionWindow,
AdditionReportingI AdditionTime,
nterval of FMCS, AdditionReportingInterv
AdditionTime of al and
FMCS, ActiveSetWeightingCoe
AdditionWindow of fficient are used in case
This parameter determines the FMCS, of event 1A.
maximum number of cells which can ReplacementRepor Parameters
Replac participate in a soft/softer handover. tingInterval of ReplacementTime,
ement Reporting deactivation threshold Mobile FMCS, ReplacementWindow
activati indicates the maximum number of Device ReplacementTime and
Maximum on cells allowed in the active set in order Control, of FMCS, ReplacementReporting
Active Set MaxActive thresh for the event 1A to trigger. The RNC Handover ReplacementWindo Interval are used in 2...3, step
Size SetSize old calculate Control w of FMCS case of event 1C. 1 3
No
periodical
reporting
(0), 0.25
s. Not
When the number of cells in the allowed
active set has reached the maximum, (1), 0.5 s
and a monitored cell becomes better MaxActiveSetSize Parameters (2), 1 s
than an active set cell, the UE Handover of FMCS, MaxActiveSetSize, (3), 2 s
transmits a Measurement Report to Control, ReplacementTime ReplacementTime and (4), 4 s
Replaceme Replacem Reporti the RNC in order to replace the active Mobile of FMCS, ReplacementWindow (5), 8 s
nt Reporting entReporti ng cell with the monitored cell (event Device ReplacementWindo are used in case of (6), 16 s 0.5 s
Interval ngInterval interval 1C). If th Control w of FMCS event 1C. (7) (2)
0 ms (0),
10 ms (1),
20 ms (2),
40 ms (3),
60 ms (4),
80 ms (5),
100 ms
(6), 120
ms (7),
160 ms
(8), 200
ms (9),
240 ms
When the number of cells in the (10), 320
active set has reached the maximum, MaxActiveSetSize Parameters ms (11),
and a monitored cell enters the of FMCS, MaxActiveSetSize, 640 ms
reporting range (replacement Mobile ReplacementRepor ReplacementWindow (12), 1280
window), the monitored cell must Device tingInterval of and ms (13),
Time continuously stay within the reporting Control, FMCS, ReplacementReporting 2560 ms
Replaceme Replacem to range for a given period of time Handover ReplacementWindo Interval are used in (14), 5000 100
nt Time entTime trigger before the UE can sen Control w of FMCS case of event 1C. ms (15) ms (6)
The
neighbour
ing cell
can
Enable Parameter indicates whether the participat
Inter-RNC EnableInt neighbouring cell can participate in a Handov e in Inter-
Soft erRNCsh soft handover, if it is controlled by a er No (0), Yes RNC Soft
Handover o RNC other than the local RNC. Control (1) Yes (1) Handover.