Like 1.5K The Heat Exchanger Inspection article Articles!
provides you with information about the
inspection of the heat exchanger and heat
Home
exchanger testing during the manufacturing
phase, as well as in-service inspection in
operating units. You may want to review
GENERAL
shell and tube heat exchanger inspection
procedure and related inspection and test
Site
Pre-Shipment
Inspection plan. Sponsors
Third Party
Inspection Shell and Tube Heat
Vendor Exchanger Inspection in
Inspection
Manufacturing Shop
Commodity
Inspection The

Inspection and
Test Plan

Factory
Acceptance
Test

Industrial
Inspection construction code for shell and tube heat
exchangers is ASME Code Section VIII,
http://www.inspection-for-industry.com/heat-exchanger-inspection.html 1/14
4/18/2018 Heat Exchanger Inspection

Quality Control and it covers the minimum requirements for


design, materials, fabrication, inspection,
Plant
testing, and preparation for initial delivery.
Inspection

Coating After the 2003 addenda of ASME Code


Inspection Section VIII Div. 1, the design of the shell
and tube heat exchanger needs to be done
based on Subsection C, in UHX part. The
FIX design based on TEMA, or any similar code
EQUIPMENT might be accepted which meeting the
requirements of UHX part.
Pressure Vessel
The heat exchanger still is a pressure
Heat Exchanger
vessel and all requirements for ASME
Piping System pressure vessel does apply for heat
exchanger as well. We are going to avoid
Industrial Valve
to repeat those requirements for the heat
Steam Boiler exchanger. You may review pressure
vessel inspection article for those
Storage Tank
requirements.
Process Heater
There are several inspection requirements
that only apply to the heat exchanger and
ROTARY not regular pressure vessel:
EQUIPMENT
Tube Inspection - The tube outside
Centrifugal diameter, inside diameter, thickness, and
Pump ovality shall be checked before the building
of the tube bundle. You need to refer to
Centrifugal
ASME Section II to get the acceptance
Compressor
tolerances.
Reciprocating
Compressor For example, if your tube material is SA
Gas Turbine 179, you have to refer to the SA 179 and
that will refer you to the SA 450 (
Steam Turbine Specification for General Requirements for
Fan & Blower Carbon, Ferritic Alloy, and Austenitic Alloy
Steel Tubes) for acceptance tolerance. You
have to use your caliper, machinist ruler,
E&I etc. to make these measurements and
make sure the values fall within acceptance
EQUIPMENT
range.

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 2/14
4/18/2018 Heat Exchanger Inspection

Electric Tube Bundle Inspection - The bundle


Generator dimension shall be checked based on the
approved drawing. The baffle diameter and
Electric Motor
distance between them shall be controlled
Power and meet the acceptance tolerances in the
Transformer drawing.

Control Panel
The tightness of stay bolts and spacers
Switchgear must be controlled. The shell cleanliness
needs to be verified and make sure the
Power Cable
inside welds are complete and are ground
as per drawing requirements.
GET IN
Tubesheet Inspection - The Tubesheet
TOUCH shall be inspected before welding to the
shell. The hole diameter, grooves
About Me
dimensions, drilling pattern, the thickness
Contact of the tubesheet and surface finish shall be
measured and checked aginst acceptance
Services
tolerances in the approved drawing.
Blog

Privacy Policy Tube Rolling Inspection - The tube rolling


shall be checked based on customer
specification. The wall reduction (after
rolling) and depth of roll shall be measured
We will be updating
and shall meet the customer specification.
and growing this
The wall reduction should not be less than
site with more and
5% and should not be more than 8% of the
more of industrial
inspection related tube wall thickness.
articles.
Leak Testing of Seal Weld (Tube to
Please subscribe to Tubesheet) - if seal welding considered,
my monthly then the leak test will be a mandatory
newsletter so you requirement. The shell side will be
don't miss a thing. subjected to the air pressure, and water
and soap solution will be sprayed to the
tubesheet to make sure all seal welds are
Email defect free. The bubble will be developed if
there was any welding defect such as
crack, pinhole, etc.

Shell side Hydrostatic Testing - After


manufacturing completion, the heat

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 3/14
4/18/2018 Heat Exchanger Inspection

exchange shell side will be subjected to the


Enter hydrostatic testing. The test pressure
amount shall be consistent with the value
Your
indicated in the approved drawing. The
First holding time shall be based on the supplier
approved test procedure.
Name
(optional) The pressure gages calibration and range
shall be controlled. The pressure gage
range shall be within 1.5 thru 4 times of test
pressure. The shell body and welding
Subscribe seams shall be inspected. The tubesheet
also shall be checked. No leakage is
allowed.

The test pump hose shall be disconnected,


and no pressure drop is allowed. The test
result will be satisfactory if no leakage
being observed and no pressure being
dropped while the shell side was under
pressure.

Tubeside Hydrostatic Testing - After


successful completion of shell side
hydrostatic testing, the bonnets are
assembled, and tube side is subjected to
hydrostatic testing. Similarly, the amount of
test pressure shall be as the one indicated
in the approved drawing. Other requirement
is similar to the shell test. No leakage and
pressure drop shall be observed while the
tube side is under pressure.

Third Party Inspection for Shell and Tube


Heat Exchanger article provides you a
procedural content for heat exchanger
inspection. Review following standard
Inspection and Test Plan for Shell and Tube
Heat Exchanger.

You might be interested in reviewing


following related articles:

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 4/14
4/18/2018 Heat Exchanger Inspection

Heat Exchanger Theory

Fin Tube Heat Exchanger Inspection

Third Party Inspection for Fin Tube Heat


Exchanger

Inspection and Test Plan for Fin Tube Heat


Exchanger

Shell and Tube Heat


Exchanger Application
Shell
and
Tube
heat

exchangers are the most popular type in


the industry. This type is made from 3
components as listed below:

Two heads (one rear head, and the


other one stationary head)
Shell
Tube

One fluid is in the tube side and the other


one in the shell side. The heat transfer is
done through the tube wall.

So your heat exchanger with more tubes


will have more heat transfer surfaces, and
at the same time will have a higher heat
exchanger diameter.

There are different kinds of shell and tube


heat exchangers with different

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 5/14
4/18/2018 Heat Exchanger Inspection

applications.The reason for the high


amount of applications is that they are easy
to maintain.

Besides, the shell and tube heat exchanger


is the only type that can be designed and
operated at a temperature greater than 360
degrees centigrade, as well as in pressure
higher than 30 bar.

In-Service Inspection of
Shell and Tube Heat
Exchanger
The
In-

Service Inspection code for shell and tube


heat exchangers is API STD 510. The other
API recommended practices and codes
also have to be used in with this Code.

Some of these Recommended Practices


are API RP 572, API RP 577, and API RP
571, and also construction code sections
might be used, such as ASME Code
Section VIII and ASME Code Section IX.

For repair, the requirement of API STD 510


or ASME-PCC-2 needs to be met. The title
of ASME-PCC-2, which was first published
in 2006, is: “Repair of Pressure Equipment
and Piping.”

Please note: if your shell and tube heat


exchanger is “U” stamped and you need to

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 6/14
4/18/2018 Heat Exchanger Inspection

do the repair, you have to use a Repair


Organization holding an “R” Stamp from the
National Board Inspection Code.

The API 510 Pressure Vessel Inspectors


are qualified persons to perform shell and
tube heat Exchanger inspection. You may
also review the Industrial Plant Inspection
article.

What are the Important


Items in the Shell and
Tube Heat Exchanger
Inspection in Overhaul?
Shell and Tube Heat Exchanger
Inspections are categorized in the following
way:

Shell and Structure in Heat Exchanger


Inspection:

Neutralization of Austenitic Stainless


Steel shell, clads, liner or weld
overlay, which contains H2S service.
The process needs to be done based
on approved procedures by a
corrosion engineer.
Neutralization is also required for
shell material with admiralty brass to
reduce the risk of SCC.
Neutralization of thermocouples, if
necessary, and doing dye penetration
http://www.inspection-for-industry.com/heat-exchanger-inspection.html 7/14
4/18/2018 Heat Exchanger Inspection

test
Sampling from shell fouling and
corrosion products and making lab
analysis and making interpretation by
corrosion engineer (if necessary)
Cutting small area of insulation sheet
and removing the insulation and
doing visual inspection for any sign of
corrosion under insulation
Thickness measurement of different
parts of shell and shell nozzles and
making corrosion rate and remaining
life calculation
Inspection of shell cleaning and
approval i.e. water jetting etc.
Checking inside surface for any
cladding, liner failure or separation
Inspection of Shell flange gasket
seating area for any erosion, damage
and cracking
Inspection of longitudinal and
circumferential weld joints, inlet and
outlet nozzles, reinforcement pads
and small bore connections for any
crack, corrosion and mechanical
damage and deformation
Dye penetration test on weld joints
that are susceptible to cracking,
austenitic flange face, weld overlay
and cladding surface and exchangers
exposed to amine and caustic
Hydrogen blistering inspection in
hydrogen services (hand lamp
procedure)
Heat exchanger support, steel
structure, foundation, bolt and nut
inspection

Bonnet in Heat Exchanger Inspection

Thickness measurement and making


corrosion rate and remaining life
calculation

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 8/14
4/18/2018 Heat Exchanger Inspection

Girth flange inspection for corrosion


and erosion
Internal surface inspection for
corrosion and fouling
Painting inspection of external
surface
Dye penetration or magnetic particle
examination of weld joints susceptible
to cracking

Tube

Bundle in Heat Exchanger Inspection

Taking care in the pulling out of tube


bundle to avoid any mechanical
damage
Sampling from tube side fouling and
corrosion products and making lab
analysis and making interpretation by
corrosion engineer (if necessary)
Controlling of water jetting or lancing
cleaning process
Controlling wire brushing process of
inner tube edge and rolling area
(preparation for ID measurement)
Inside diameter measurement in
tubes and tubes rolling areas
Rate off and accordingly plugging the
tubes when their OD reaches to the
ID plus one thickness
Retubing of tube bundle if more than
10% of tubes reach the above
rejection limit
Inspection from tube bundle
components such as tubesheet, tube,
tie rods and spacers, transfer baffles
http://www.inspection-for-industry.com/heat-exchanger-inspection.html 9/14
4/18/2018 Heat Exchanger Inspection

or support plate, impingement baffle,


floating head flange and floating head
backing device
Inspection from internal surface of
tubes for corrosion and fouling
Pulling out a sample tube for
sectioning and corrosion anlaysis if
necessary
Retubing when sectioning result
proves the thickness is half of the
nominal value
Visual inspection and dye penetration
test from tube to tubesheet seal or
strength weld
Eddy current testing if it is necessary

Channel in Heat Exchanger Inspection

Thickness measurement and making


corrosion rate and remaining life
calculation
Inspection of gasket seating area,
pass partition and nubbing for
corrosion and deformation
Inspection of internal surface for
fouling, corrosion and soundness of
linings (if any)
Balance hole inspection for corrosion
and erosion
Welding joints inspection for any
possible cracks
Reinforcement pad inspection and
doing soap test if necessary
Cathodic protection anodes
inspection and replacement if
necessary
Diaphragm and division box visual
inspection and dye penetration test of
diaphragm for any possible cracks
(for high pressure exchangers)

Channel Cover in Heat Exchanger


Inspection

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 10/14
4/18/2018 Heat Exchanger Inspection

Thickness measurement and making


corrosion rate and remaining life
calculation
Inspection of gasket seating area for
corrosion and deformation
Inspection for internal surface for
fouling, liner, cladding and coating
soundness
Soap test in channel cover with liner
Lifting lug weld joint inspection for any
possible crack

Floating Head Inspection:

Thickness measurement and making


corrosion rate and remaining life
calculation
Inspection of gasket seating area,
pass partition and nubbing for any
possible corrosion and deformation
Girth flange weld joint inspection for
any possible crack and corrosion
Internal surface inspection for
corrosion and fouling and soundness
of liner, coating and cladding (if any)

Expansion Joint Inspection

The heat exchangers with expansion


joints need to be inspected for:
Flange inspections for corrosion and
erosion
Inspection from internal surface for
corrosion and erosion
Air test

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 11/14
4/18/2018 Heat Exchanger Inspection

The tube and shell hydrostatic test


need to be done after the above
stated inspection activities.

Related Articles
Boiler Inspection, Above Ground Storage Tank
Inspection, Piping Inspection, Valve Inspection,
Heater Inspections, Pressure Vessel Certification,
Pressure Vessel RT Test, Pressure Vessel Dimension
Inspection, ASME Impact Test Requirement, ASME
Pressure Vessel Joint Efficiencies, Pressure Vessel
Plate Material

Like Share 1.5K people like this. Sign Up to see what your friends like.

Did you find this article useful? Click on


below Like and G+1 buttons!

Like 1.5K

New! Comments
Have your say about what you just read!
Leave me a comment in the box below.

13 Comments Sort by Newest

Add a comment...

Pramono Tirtohamijoyo ·
Institut Teknologi Sepuluh Nopember
It is good for reference... it is beneficial for me... how I can get
free standard API for shell and tube exchanger?
Like · Reply · 1 · 5y

Hasta Prayitna
Useful........... very good.
Like · Reply · 4 · 5y

Sujen Saithong
It is very good for new beginer to learning.
http://www.inspection-for-industry.com/heat-exchanger-inspection.html 12/14
4/18/2018 Heat Exchanger Inspection
t s e y good o e beg e to ea g
Like · Reply · 1 · 5y

Lalu Rajendran ·
Sr.Engineer QA/QC at Links Middle East Technical Services LLC
it is very useful.....especially for oil&gas professionals.
Like · Reply · 5y

Nikhil Raj ·
QA/QC Engineer at Amana Group
useful..........we can know which standard has to follow for
different activities and inspection.
Like · Reply · 5y

Mot G. Oleur ·
Instructor at Negros Oriental State University
very useful for me. thanks a lot,. please continue to inspires us.
Like · Reply · 1 · 4y

Atta Ul Noor Saquib ·


Director International Business Affairs at Sirius Gemstone e.s Drilling Fluids
very useful
Like · Reply · 4y

Syed Raza Ali Zaidi ·


HVAC Engineer (Heating Ventilation Air Conditioning Engineer) at Al futtaim
Thank You Its very Use Ful Articles For Me Thankx again
Like · Reply · 3y

Graham Clark ·
Engineer at Self-employed
Super site can give you more examples and information if
required
Like · Reply · 3y

Blair Tucker Gilman ·


East Carolina University
Need a great piece of equipment to help with heat exchange
tube bundle lifting? Go to www.careylift.com.
Like · Reply · 3y

Load 3 more comments

Facebook Comments Plugin

Share on  Facebook  Twitter

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 13/14
4/18/2018 Heat Exchanger Inspection

inspection-for-industry.com
Copyright © 2012-2013 Inspection-for-Industry.Com

http://www.inspection-for-industry.com/heat-exchanger-inspection.html 14/14

Vous aimerez peut-être aussi