PERMA-PIPE ®/ RICWIL®

Preinsulated Piping Systems

ULTRA-THERM ™

· The Strength of Steel Combined with the Corrosion Resistance of Fiberglass


· No Pipe Coating Can Equal the Thick Fiberglass Cladding
· Designed to Withstand 35,000 Volt Spark Testing
· No Cathodic Protection Required

… 100 mil thick filament wound


fiberglass reinforced plastic

… 10 gauge minimum steel conduit

… Air space
…
…

Insulation, as specified

Pipe, as specified

In the mid 1990’s PERMA-PIPE introduced the ULTRA Series designed to withstand 35,000 volt spark testing, thus
for the safe underground transportation of hazardous eliminating the need for cathodic protection. No pipe coating
chemicals in a DOUBLE-PIPE family of products. After years can meet the performance of the ULTRA-THERM fiberglass
of experience and further research and development, it is cladding.
finally time to introduce this corrosion fighting product into
the heat distribution market. Developed especially for underground applications and for
severe above grade environments, the fiberglass cladding
The ULTRA-THERM outer casing is manufactured of 10 gauge is filament wound directly onto a shot blasted steel conduit.
steel casing clad with a thick layer of filament wound The smoothwall conduit is chosen for this product because
fiberglass reinforced plastic for maximum resistance to of its small seam, providing complete bonding of the cladding
adverse environmental conditions. This fiberglass clad to the casing.
system is built to fight and defeat corrosion.
The casing is capable of withstanding earth and H20 traffic
ULTRA-THERM has the strength of steel and the corrosion loads. The ULTRA-THERM cladding also resists the
resistance of fiberglass. The fiberglass cladding is highly stresses of handling, soil movement and backfill compaction.
resistant to acids, alkalis, salts and chemicals found in the ULTRA-THERM is manufactured in 20-foot lengths or
soil. This material has a high dielectric strength and is 40-foot lengths with fittings, odd lengths and accessories
as required.
SPECIFICATIONS

ULTRA-THERM™ Fiberglass Clad Steel Conduit Systems


GENERAL SERVICE PIPE INSULATION OUTER CONDUIT CLADDING
All underground heat distribution lines, Service pipe insulation shall be mineral The conduit surface shall be clad with
as shown on the contract drawings, wool. Split insulation shall be held in filament wound fiberglass reinforced
shall be fiberglass clad steel conduit place by stainless steel bands installed plastic to a minimum thickness of
ULTRA-THERM, as manufactured by on 18-inch centers. The insulation shall 100 mil. All fitting assemblies shall be
PERMA-PIPE. The system supplier have passed the boiling test and other clad with chopped fiberglass to the
shall have at least five years experience requirements specified in the Federal same thickness. The final outside clad-
in fabricated systems of the composi- Agency Guidelines. The insulation shall ding shall be designed to withstand
tion defined herein. All straight sec- be applied to a thickness of ______ 35,000 volt spark testing, thus eliminat-
tions, fittings, anchors and other ac- inches. ing the need for cathodic protection.
cessories shall be factory prefabricated
to job dimensions. Each system lay- OUTER CONDUIT INSTALLATION
out shall be analyzed by the piping sys- The steel conduit casing shall be The installing contractor shall handle
tem manufacturer to determine stresses smoothwall, welded steel conduit of the the system in accordance with the
and movements of the service pipe. The thicknesses specified below: directions furnished by the manufac-
system design shall be in strict con- turer and as approved by the architect
formance with ANSI B31.1 latest edi- Conduit Size Conduit Thickness and engineer. The casing shall be air
tion and stamped by a Registered Pro- tested at 15 psig. The service piping
fessional Engineer. Factory trained field 6” - 26” 10 Gauge shall be hydrostatically hammer tested
technical assistance shall be provided 28” - 36” 6 Gauge to 150 psig or 1.5 times the operating
for critical periods of installation, 38” - 42” 4 Gauge pressure, or as specified in the con-
unloading, field joint instruction and tract documents. The test pressure
testing. Changes in casing size, required to shall be held for not less than one hour.
allow for service pipe expansion,
SERVICE PIPE shall be accomplished by eccentric BACKFILL
Internal piping shall be standard weight and/or concentric fittings and shall pro- A 4-inch layer of sand or fine gravel
carbon steel, except for condensate pip- vide for continuous drainage. shall be placed and tamped in the
ing which shall be Schedule 80 carbon trench to provide a uniform bedding for
steel. All joints shall be butt welded for PIPE SUPPORTS the system. The entire trench shall be
sizes 2.5 inches and larger and socket All pipes within the outer casing shall evenly backfilled with a similar mate-
welded for 2 inches and below. Where be supported at not more than 10-foot rial as the bedding in 6-inch compacted
possible, straight sections shall be sup- intervals. These supports shall be de- layers, to a minimum height of 6 inches
plied in 40-foot random lengths with signed to allow for continuous airflow above the top of the insulated piping sys-
6 inches of piping exposed at each end and drainage of the conduit in place. tem. The remaining trench shall be
for field joint fabrication. The straight supports shall be designed evenly and continuously backfilled
to occupy not more than 10% of the in uniform layers with suitable excavated
SUBASSEMBLIES annular air space. Supports shall be soil.
End seals, gland seals and anchors of the type where insulation thermally
shall be designed and factory prefabri- isolates the service pipe from the outer
cated to prevent the ingress of mois- conduit. The surface of the insulation
ture into the system. All subassemblies shall be protected at the support by a
shall be designed to allow for complete sleeve not less than 12-inches long,
draining and drying of the conduit fitted with traverse and, where required,
system. rotational arresters.