Vous êtes sur la page 1sur 1

Jet Throw from Spillway Flip Bucket & Depth of Plunge Pool with Original River Bed

Reservoir Level (masl) 1160


Invert level of Lip of Bucket(masl) 1065
Bucket Lip angle with Horizontal(deg.,rad.) 30 0.524
Rugosity, k (m) 0.002
Width, B (m) 155.50
Length along the Chute, Lc (m) 138.82
Power House Discharge, (m 3/s) 2850.00

Input Parameters by Model, (starting section at 1140.00 masl) Theoretical Jet Trajectory Actual Jet Trajectory Plunge Pool

Depth of Scour below TWL Ds

Return Froude No. Velocity X/Xt Martins Veronese


QSpillway q=Q/B TWL
Period d (m) V (m) Head he y (m) Xt (m) F2 (Taraimovi X (m) h (m)
(m3/s) (m3/s) (masl) Bottom Ds Bottom
(Years) F (m) ch) Ds
Level Level
(m) (masl) (masl)
(m)

4000.00 25.72 0.79 32.59 11.71 54.13 965.90 99.10 182.13 137.12 -- -- 153.23 17.41 948.49 34.04 931.86

6000.00 38.59 1.09 35.34 10.80 63.66 966.94 98.06 202.66 116.64 0.66 133.76 161.72 22.33 944.61 42.89 924.04

10 11360.00 73.05 1.92 37.99 8.75 73.56 968.98 96.02 222.60 76.56 0.81 180.31 169.58 32.90 936.08 61.20 907.78

100 14330.00 92.15 2.39 38.52 7.95 75.63 969.85 95.15 226.36 63.20 0.90 203.73 170.77 37.85 932.01 69.48 900.37

1000 17250.00 110.93 2.86 38.82 7.33 76.81 970.60 94.40 228.32 53.73 0.95 216.90 171.21 42.31 928.29 76.85 893.75

10000 18865.00 121.32 3.12 38.92 7.04 77.21 970.97 94.03 228.88 49.56 1.00 228.88 171.23 44.65 926.33 80.65 890.32

V2
he =
2g
TWL=945+3 . 96658Q
1 0 .188187
Q1 =Q Spillway +Q Powerhouse
y=1065−TWL

[
X t =he Sin2θ +2 cosθ× sin2 θ +
√ y
he ]
D s =1 .5×h 0. 1 ×q 0. 6 ( Martins Formula)
0. 225 0 .54
D s =1 . 9×h ×q (Veronese Formula)
h= he + y