A.7.3 컨트롤 밸브의 누설등급 ( ANSI.B16.

104)
Leakage Maximum
Testing Procedures Required
Class Leakage Test Medium Test Pressures
for Establishing Rating
Designation Allowable
No test required provided user and supplier so
I … … … agree.
0.5% of rated Air or water 45-60 psig or max. Pressure applied to valve inlet, with outlet open to
capacity at 50-125℉ operating differential, atmosphere or connected to a low head loss
II
(10-52℃) whichever is lower measuring device, full normal closing thrust
provided by actuator.
0.1% of rated As above As above As above
III
capacity
0.01% of rated As above As above As above
IV
capacity
0.0005 ml per Water at Max. service pressure Pressure applied to valve
minute of 50-125℉ drop across valve inlet after filling entire body
water (10-52℃) plug, cavity and connected
per inch of not to exceed ANSI piping with water and
port body stroking valve plug closed.
V diameter per rating.(100 psi Use net specified max.
psi pressure actuator thrust, but no
differential drop minimum) more, even if available
during test. Allow time for
leakage flow to stabilizer.
Not to exceed Air or 50 psig or max. rated Actuator should be
amounts Nitrogen differential pressure adjusted to operating
shown at across valve plug, conditions specified with
in following 50-125℉ whichever is lower. full normal closing thrust
VI table (10-52℃) applied to valve plug seat.
based on port Allow time for leakage flow
diameter to stabilize and use suitable
measuring device.
A
.
7
Class VI Seat Leakage Allowable
(In accordance with ANSI B16.104-1976)

NOMINAL PORT DIAMETER LEAK RATE


Inches Millimeters ml Per Minute Bubbles Per Minute
1” 25 0.15 1
1 1/2” 38 0.30 2
2” 51 0.45 3
2 1/2” 64 0.60 4
3” 76 0.90 6
4” 102 1.70 11
6” 152 4.00 27
8” 203 6.75 45

Bubbles per minute as tabulated are an easily measured suggested alternative based on a suitable
calibrated measuring device such as a 1/4-inch O.D. x 0.032-inch wall tube submerged in water to a
depth of 1/8-inch to 1/4-inch. The tube end shall be cut square and smooth with no chamfers or
burrs and the tube axis shall be perpendicular to the surface of the water. Other apparatus may be
constructed and the number of bubbles per minute may vary from these shown, as long as they
correctly indicate the flow in ml per minute.