Vous êtes sur la page 1sur 7

Design Calculations

U
Hydraulic Size
DESIGN Wetted Hydraulic
RD Design Flow (Q) Area
VELOCITY Bed Perimeter Radius
Depth Manning's
Length Width
Sr. B/D Coeff
No. ratio P=B+2D((z^
From To This Line Previous Total V B D A=(B+zD) D R=A/P
2+1)^0.5)

(m) (m) (m) (m3/sec) (m3/sec) (m3/sec) (m/sec) (m) (m) (m) (m2) (m) (m) n
1 0 70 70 12.500 0.000 12.500 2.327 6.00 0.895 6.70 5.372 7.79 0.690 0.015
2 70 80 10 0.000 12.500 12.500 2.154 8.00 0.725 11.03 5.803 9.45 0.614 0.015
3 80 150 70 12.500 12.500 25.000 2.722 18.00 0.510 35.28 9.184 19.02 0.483 0.015

3
Design Calculations

UP03 Channel

Velocity
Side Longitudinal Road Level Invert Level Actual Actual Top Level
Running Average
Slope Slope Capacity R.L I.L Total Length of Total T.L
Full Dpeth
Running Drop Depth Selected Depth
of
Full from Reaches from T.L
S=((V n)/ Reaches
Z:1 V=Q/A R.L to B.L U/S D/S
(R^(2/3)))^2
U/S D/S U/S D/S

(m/m) (m3/sec) (m/s) (m) (m) (m) (m) (m) (m) (m) (m) (m) (m) (m)
0.0 0.00200 12.485 2.33 3.00 3.00 0.20 1.90 1.76 1.10 1.10 70 1.10 3.00 3.00
0.0 0.00200 12.480 2.15 3.00 3.00 0.00 1.76 1.74 1.24 1.24 10 1.24 3.00 3.00
0.0 0.00440 24.939 2.72 3.00 3.00 0.00 1.74 1.44 1.26 1.26 70 1.26 3.00 3.00

4
Design Calculations

Free Top
Water Level
Board Width
Water
Depth
BT = 2z
FB (D+FB) U/S D/S
+B

(m) (m) (m) (m) (m)


0.90 0.20 6.00 2.80 2.66
0.73 0.34 8.00 2.66 2.47
0.51 0.53 18.00 2.47 1.95

5
Rectangular Open Channel

Flow Q m3/sec 10
Channel Width W m 6
Roughness Coef n 0.015
Channel Slope S m/m 0.0001
Depth of Water H m 2.15
Velocity V m/sec 0.78
Length of Channel L m 70
Upstream Invert Level u/s I.L m 1.70
Downstream Invert Level d/s I.L m 1.69

Upstream Water Level u/s W.L m 3.85


Downstream Water Level d/s W.L m 3.84
Design Calculations

U
Hydraulic Size
DESIGN Wetted Hydraulic
RD Design Flow (Q) Area
VELOCITY Bed Perimeter Radius
Depth Manning's
Length Width
Sr. B/D Coeff
No. ratio P=B+2D((z^
From To This Line Previous Total V B D A=(B+zD) D R=A/P
2+1)^0.5)

(m) (m) (m) (m3/sec) (m3/sec) (m3/sec) (m/sec) (m) (m) (m) (m2) (m) (m) n
1 0 100 100 12.500 0.000 12.500 2.327 6.00 0.895 6.70 5.372 7.79 0.690 0.015
2 100 120 20 0.000 12.500 12.500 2.154 8.00 0.725 11.03 5.803 9.45 0.614 0.015
3 120 190 70 12.500 12.500 25.000 2.722 18.00 0.510 35.28 9.184 19.02 0.483 0.015

3
Design Calculations

UP03 Channel

Velocity
Side Longitudinal Road Level Invert Level Actual Actual Top Level
Running Average
Slope Slope Capacity R.L I.L Total Length of Total T.L
Full Dpeth
Running Drop Depth Selected Depth
of
Full from Reaches from T.L
S=((V n)/ Reaches
Z:1 V=Q/A R.L to B.L U/S D/S
(R^(2/3)))^2
U/S D/S U/S D/S

(m/m) (m3/sec) (m/s) (m) (m) (m) (m) (m) (m) (m) (m) (m) (m) (m)
0.0 0.00200 12.485 2.33 3.00 3.00 0.20 1.90 1.70 1.10 1.10 100 1.10 3.00 3.00
0.0 0.00200 12.480 2.15 3.00 3.00 0.00 1.70 1.66 1.30 1.30 20 1.30 3.00 3.00
0.0 0.00440 24.939 2.72 3.00 3.00 0.00 1.66 1.36 1.34 1.34 70 1.34 3.00 3.00

4
Design Calculations

Free Top
Water Level
Board Width
Water
Depth
BT = 2z
FB (D+FB) U/S D/S
+B

(m) (m) (m) (m) (m)


0.90 0.20 6.00 2.80 2.60
0.73 0.40 8.00 2.60 2.39
0.51 0.61 18.00 2.39 1.87

Vous aimerez peut-être aussi