Académique Documents
Professionnel Documents
Culture Documents
Multifunction
Types DMB01, PMB01
• Time range 0.1 s to 100 h
• 7 knob selectable functions:
Op - delay on operate
In - interval
Io - interval on trigger open
Id - double interval
Dr - delay on release
R - symmetrical recycler ON first
Rb - symmetrical recycler OFF first
• Knob selection of time range
• Knob-adjustable time setting
• Automatic or manual start
• Repeatability: ≤ 0.2%
DMB 01 PMB 01 • Output: 8 A SPDT or 8 A DPDT relay
• For mounting on DIN-rail in accordance with DIN/EN
50 022 or Plug-in
• 22.5 mm Euronorm or 36 mm Plug-in module housing
• Combined AC and DC power supply
• LED indication for relay status and power supply ON
Type Selection
Mounting Output Housing Supply: 24 VDC and 24 to 240 VAC Supply: 24 to 240 VAC/DC
Mode of Operation
Function Op keeps ON and a new time the relay operates again for Function R
Delay on operate period starts. the set delay period. If the Symmetrical recycler, ON-
The time period begins as trigger contact is opened time period first
soon as the trigger contact Function Io before the end of the first The relay operates and the
is closed. Interval on trigger open time period the second one time period begins as soon
At the end of the set delay The relay operates and the begins; if the trigger contact as the input contact is
time the relay operates and time period begins as soon is closed before the end of closed. After the set delay
doesn't release until the trig- as the trigger contact is the second time period the period the relay releases for
ger contact is closed again opened. At the end of the relay keeps ON and the first the same time period. This
or the power supply is dis- set delay or when the power time period begins again. sequence continues with
connected. If the trigger supply is disconnected the equal ON- and OFF-time
contact is closed before the relay releases. The relay Function Dr periods until the power sup-
end of the delay time, the operates again when the Delay on release ply is interrupted.
device resets and a new trigger contact is opened The relay operates as soon
time period starts. again. If the trigger contact as the trigger contact is Function Rb
is opened before the end of closed. The time period Symmetrical recycler,
Function In the delay time the relay begins when the trigger con- OFF-time period first
Interval keeps ON and a new time tact is opened. The relay The time period begins as
The relay operates and the period begins. releases at the end of the soon as the input contact is
time period begins as soon set delay time or when the closed. The relay is OFF
as the trigger contact is Function Id power supply is disconnect- during the set delay period,
closed. The relay releases at Double interval ed. The relay operates again after this time it operates for
the end of this period or The relay operates and the when the input contact is the same time period. This
when the power supply is time period begins as soon closed again. If it is closed sequence continues with
disconnected. The relay as the trigger contact is before the end of the delay equal OFF- and ON-time
operates again when the closed. The relay releases at time the relay keeps ON, a periods until power supply is
trigger contact is closed the end of this period or new time period begins as interrupted.
again. If the trigger contact when the power supply is soon as the contact is
is closed before the end of disconnected. When the opened again.
the delay time, the relay trigger contact is opened
Operation Diagrams
Function Op - Delay on operate - Manual start Function In - Interval - Manual start
T T T T
Relay ON ON Relay ON ON
OFF OFF
LED LED
T T T T
Relay ON ON Relay ON ON
OFF OFF
LED LED
T T T T
Relay ON ON Relay ON ON
OFF OFF
LED LED
T T T T T
Relay ON ON Relay ON ON
OFF OFF
LED LED
Power supply
Trigger input
T T T T
Relay ON ON
OFF
LED
Wiring Diagrams
DMB 01 PMB 01
L(+) L(+)
m m m m
S A1 16 18 26 28 S 2 4 3 8 9
Y1 5
A2 15 25 10 1 11
DMB01C... DMB01D... PMB01C... PMB01D...
DMB01D... PMB01D...
N(-) N(-)
Dimensions
DIN-rail Plug-in
22.5 94
99.5
36 90
83.5
80
63
63
80
28.5 28.5