Académique Documents
Professionnel Documents
Culture Documents
Cathodic ASTM G8 - "Cathodic 1 x 500µm dft applied Typically less than 3mm
Disbondment Disbonding of Pipeline directly to Sa2.5 blasted disbondment following
Coatings" , Method A steel 30 days exposure.
@ -1.5 volts
Condensation ISO 6270 - "Resistance 1 x 500µm dft applied No film defects after 1
to continuous directly to Sa2.5 blasted year exposure.
condensation @ 35°C" steel.
Cyclic Corrosion ASTM D5894 - "Cyclic 1 x 500µm dft applied No film Defects, and an
Salt Fog / UV Exposure directly to Sa2.5 blasted average of 6.5mm rust
of a Coated Metal" steel creep at the scribe after
4200 hours exposure (12.5
cycles).
All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements
herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose
2004-10-15 Page 1 of 3
www.international-pc.com
Performance Test Data for Interzone 954
Hydrocarbon Modified Epoxy
Immersion ISO 2812 Part 2 - 1 x 500µm dft applied No film defects after 1
"Resistance to water directly to Sa2.5 blasted year exposure.
immersion @ 40°C" steel.
Salt Spray ISO 7253 - "Resistance 1 x 450µm dft applied No film defects, and an
to neutral salt spray directly to Sa2.5 blasted average of 3.5mm rust
(fog) @ 35°C" steel. creep at the scribe after
6000 hours exposure.
Salt Spray BS 3900 Part F4 - 1 x 500µm dft applied No film defects, and an
"Resistance to directly to Sa2.5 blasted average of 3mm rust
continuous salt spray @ steel creep at the scribe
20°C" following 4000 hours
exposure.
Adhesion ISO 4624 - "Pull-off test 1 x 500µm dft applied Not less than 10MPa
for adhesion" using directly to Sa2.5 blasted (1450psi) when using a
portable adhesion steel. PAT Model GM01
testers hydraulic adhesion tester
on 5mm thick steel.
All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements
herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose
2004-10-15 Page 2 of 3
www.international-pc.com
Performance Test Data for Interzone 954
Hydrocarbon Modified Epoxy
Tensile Strength ASTM D2370 - "Tensile 1 x 900µm dft "free film". An average of 11MPa
& Elongation (1595 psi) is required to
Properties of Coatings" achieve fracture of the
coating.
All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements
herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose
2004-10-15 Page 3 of 3
www.international-pc.com