Rotary filter (F-202)

Fungsi : Untuk memisahkan SiO2 dari filtrat dan mencuci cake


pengotor dengan air
Kondisi Operas : Tekanan masuk 1 atm
Temperatur 92,8 oC

Komposisi Filtrat
ρ ρc Fraksi
Komposisi Massa μ (cp)
(Kg/m3) (Kg/m3) massa
Na2O.3,2 SiO2 1,023.87 2610 51.319502 0.019663 25
H2SO4 61.81 1751.847 2.0795903 0.001187 4.9162074
Na2SO4 5,456.29 2444.7 256.1647 0.104784 0.0002214
H2O 45,529.95 965.6261 844.31119 0.874367 0.3113209
Total 52071.91948 1153.875 1
μc = 0.769633855 cp = 0.0007696 Kg/m.s

Komposisi Cake
Fraksi
Komposisi Massa ρ ρc μ
massa
SiO2 6,736.11 3156.61 2775.9051 0.879394 0.3
H2O 923.83 965.6261 116.45993 0.120606 0.3113209
Total 7659.938402 2892.365 1
μc = 0.301365364 cp 0.0003014 Kg/m.s

Dari Silla, 2003, pers.6.18-5, hal. 321 didapat :

Dimana :
VF : Laju Volumetrik filtrat, m3 /det
AF : Luas Permukaan flter , m2
tF : waktu siklus (time cycle) filter, det
C1,2 : Konsentrasi padatan dalam umpan, kgpadatan/m³filtrat
Po - Pv (∆P) : perbedaan tekanan, Pa
a : tahanan cake, m /kg padatan
n : fraksi (bagian) filter terbenam
m : viskositas filtrat, Pa.det

Laju Filtrasi
Rate Filtrat = 52071.91948 Kg/jam 867.86532 kg/min
ρ camp filtrat = 1153.874981 Kg/m3
VF = 45.12786944 m3/jam 0.0125355 m3/s

Perbedaan tekanan
Dari Geankoplis ed. 4 hal 909 maksimum ∆P untuk rotary filter = 1 atm,
∆P = 0.658 atm 66671.85 Pa
= 0.6667185 bar (Silla, 2003, hal.323)
(-∆P) / 0.67 tF = (100 L)2 (wallas , pers 11.28)
Dimana : L = 1 cm 0.01 m (Wallas, hal 318)
tF = 0.995102239 menit
= 59.70613433 detik

Perhitungan ukuran filter :


1. Dari Wallas, ketebalan cake yang dibentuk adalah
t= 1 cm
2. Dari gambar 18 - 98, Perry dan Green, 1999
W= 14 kg dry cake/(m2 x rev)
3. Dari perhitungan diketahui waktu pembentukan cake :
f = 0.995102239 menit
4. Laju pencucian :
Menghitung konsentrasi filtrat dalam cairan pencucian cake :
Filtrat di cake = 13.93143134 Kg/m2 x cycle
Filtrat dalam padatan kering = 0.285714 Kg/m2 x cycle
Filtrat dalam cairan pencuci cake akhir = 2.050861 % berat
Persen sisa, = (C2-Cw) * 100
C1-Cw
Dimana Cw = 0, persen sisa yang diperlukan,
R = C2 *100% = 14.72
C1
Dari gambar 18-103, Perry, 1999, rasio pencucian,
N= 0.8
Untuk desain ditambahkan 10%, 0.08
N= 0.88 = 0.88
Volume air pencuci = Vw = (Ndesain X Cairan cake)/1
Vw = N x cairan cake
= 12.25965958 L/m2xcyle
6. Waktu pencucian :
W x Vw= 171.6352341 KgL/m3

Dari gambar 18-104, Perry, 1999, waktu pencucian,


W= 1.1 menit
7. Waktu siklus (cycle time, CT) untuk basis waktu pembentukan dan waktu
pencucian :
CT form = 2.06 mpr (min/rev)
CT wash = 1.11 mpr (min/rev)
maka digunakan 3,17 mpr (min/rec)
8. Faktor overall scale up ditetapkan
0.9 x 1.0 x 1.0 = 0.9 (Perry dan Green, 1999)

9. Laju filtrasi
mf = W x Fs
CT form
= 756 Kg/min x m2
10. Area yang diperlukan untuk menyaring :
A = Laju alir filtrat
Laju filtrasi
= 1.15 m2
Mencari Luas Drum (AT)

Silla, 2003 pers 6.18.9


f= 0.375 (untuk rotari filter, Silla, 2003, tabel 6.20)
AT = 3.06125335 m2 = 32.93909 ft2

Dari Silla, 2003 Tabel 6.20 didapatkan ukuran standar Rotary Filter
Luas Drum = 32.93908605 ft2 = 10.03983 m
Diameter = 8 ft = 2.4384 m
Panjang = 6 ft = 1.8288 m
Drum Drive = 1 hp
Agitator Drive = 1.5 hp

Menentukan Tekanan Desain (Pd)


P total = Tekanan vessel + Tekanan Atmospheric
= 1.342 atm = 19.72203 psi
Pd = 21.6942352 psi = 149.5765 kPa

Bahan Konstruksi Carbon Steel SA-283 Grade C


E= 0.8 (Brownell & Young, page 347)
S= 12750 Psia = 87908.19 kPa
Ca = (0,125 in/tahun x 10 tahun)
= Peters,
t = 𝑃𝐷/(2 1.25𝑃)in+ Ca
𝑆𝐸et.al.,
−1,2 = 0.03175 m
2004

Tebal shell : cylindrical

t= 149,577 kpa x 2,4384 m


+0,0318
2(87908,19 kpa x 0,85) - 1,2(149,577 kpa)
t= 0.0343 m = 1.3522 in
Maka tebal shell standar yang digunakan 1,5 in (Brownell & Young, 1959)

RESUME
Kode : F-202
Fungsi : Memisahkan komponen padat
dengan liquid dengan metode filtrasi
Jenis : Rotary drum filter
Bahan Konstruksi: Carbon Steel SA-283 Grade C
Joint Effisiency : 0.8
Faktor Korosi : 0.0032 m
Berat umpan : 52071.9 kg/jam
luas area filter : 1.15 m2
Laju Filtrasi : 756 kg/min.m2
Waktu Siklus : 1.00 menit
Luas Drum : 10.04 m2
Drum Drive : 1 hp
Agitator Drive : 1.50 hp
P total : 149.58 kPa
Tebal shell : 0.03 m
Dari Perry ed.8 halaman 18-90, range tc = 0.1 - 10 menit

Tahanan cake , α
α = αo x (∆P(untuk
)n ∆P konstan, pers. 6-21 Silla, 2003 hal 318)
dimana : = 0.6 (Tabel 6-17 Silla, 2003 hal 319)
αo = 1.6E+10 m/Kg (tabel 11-7, hal. 341, Wallas)
a = 1.26E+13 m/Kg
Mencari Konsentrasi Solid pada umpan

Silla, 2003 pers 6.18.8

C1,2 = 149.2671 Kg solid / m3 filtrat


Mencari Luas Filter
AF 2 = 22.814 m4
Filter Press (FP-201)
Fungsi : Memisahkan komponen padat dengan liquid dengan metode filtrasi
Kondisi Operasi 162 oC
1 atm

Jenis filter press = Horizontal plate filter ; (Wallas hal 324)


Berat umpan = 55,892.39 kg/jam
Berat cake = 5,721.03 kg/jam
Berat filtrate = 50,171.36 kg/jam

Cake
Komponen densitas m umpan m cake m filtrate X umpan
SiO2 2650.489 709.87 709.87 0.01
Al2O3 3951.0032 74.27 74.27 0.00
CaO 3354.84 70.46 70.46 0.00
MgO 3582.11 82.84 82.84 0.00
K2O 2358.987 365.64 365.64 0.01
Fe2O3 5240.75 55.23 55.23 0.001
NaOH 1851.65417 295.29 23.62 271.66 0.01
Na2O.3,2SiO2 2475.4423 10794.41 863.55 9930.86 0.19
H2O 889.767391 43444.38 3475.55 39968.83 0.78
Total 55892.39 5721.03 50171.36 1
Komponen X cake X filtrate ρ. Xumpan ρ. X cake ρ.Xfiltrat
SiO2 0.12 33.66 328.87
Al2O3 0.01 5.25 51.29
CaO 0.01 4.23 41.32
MgO 0.01 5.31 51.87
K2O 0.06 15.43 150.77
Fe2O3 0.01 5.18 50.59
NaOH 0.00 0.01 9.78 7.65 10.03
Na2O.3,2SiO2 0.15 0.20 478.08 373.65 9930.86
H2O 0.61 0.80 691.60 540.54 708.83
Total 1 1 1248.53 1596.55 10649.7
maka,
Densitas umpan = 1248.53 kg/m3
Densitas cake = 1596.55 kg/m3
Densitas filtrat = 10649.72 kg/m3

Asumsi
Kecepatan filtrat = 1 m/jam
Volume umpan = berat umpan
rho umpan
= 44.77 m3/jam

Luas total = vol umpan


kec.filtrat
= 44.77 m2

Data literature (Wallas hal 349 Tabel 11.11)


Tebal Plate = 0.025 m
Ukuran plate = 1.2 m
Luas efektif perchamber = 2.500 m2
Kapasitas perolehan cake per chamber = 31.400 m3
(per 25 mm tebal chamber )
Jumlah plate = luas total
luas efektif perchamber
= 17.91
= 18 plate
Dari tabel 11.7. Walas, diketahui resistensi dari cake 3,14 x 1010 m/kg
maka, tekanan yang diberikan adalah : 1,4 p(Wallas, hal. 341)
Digunakan media filter yaitu wedge wire screen dengan porosity 5% (wallas, 339).
Kebutuhan Daya untuk Filter Press = 30 KW = 40,23 HP
(http://www.huber.de/solutions/energy-efficiency/sludge-treatment/dewatering.html)
RESUME
Kode FP-201
Fungsi Memisahkan komponen padat
dengan liquid dengan metode filtrasi
Jenis Horizontal plate filter
Bahan Konstruksi Carbon Steel SA-283 Grade C
Media Filter Wedge Wire Screen
Tekanan 9.65 kPa
Berat umpan 55892.39 kg/jam
Berat cake 5721.03 kg/jam
Berat filtrate 50171.36 kg/jam
Luas total 44.77 m²
Ukuran plate 1.2 m
Jumlah plate 18 plate
Tebal plate 0.03 m
volume cake tiap plate 31.40 m³
Luas efektif perchamber 2.50 m
Kebutuhan daya 40 HP
X umpan

ρ.Xfiltrat
n porosity 5% (wallas, 339).

-treatment/dewatering.html)
Screener (S-201)
Fungsi : Menyeragamkan ukuran Precipitated Silica 300 mesh
Jumlah : 1 buah
Tipe Alat : Electrically Vibrated Screens square openings

Kapasitas (Q) = 6,944.44 Kg/Jam


= 6.94444 ton/jam
Ukuran yang diinginkan 300 mesh
Spesifikasi (tabel 19-6 Perry 7th edition)
sieve designation = 53 micron
sieve opening (a) = 0.053 mm 0.0021 in
wire diameter (d) = 0.037 mm 0.0015 in

Mementukan Luas Screening


0.4 Ct
A = (Pers 19-7 Perry, 7th edition)
Cu Foa Fs
Dimana A = luas screen
Ct = laju alir massa
Cu = unit kapasitas
Foa = faktor open-area
Fs = faktor slotted opening area

Tipe screener yang digunakan yaitu square openings spesified in mesh, m


Foa = 100 a2 m2
(Figure 19-22 Perry, 7th Edition)
m = 1/(a+d)
m = 277.7778 in
Foa = 34.02778 in
Fs = 4 (Tabel 19-7 Perry, 7th Edition)
Cu = 7 ton/jam.ft2
(Figure 19-21 Perry, 7th Edition)
Ukuran Screen square openings : 1/4 in
A = 0.002915 ft2
panjang sisi = 0.053995 ft

Getaran screener :600-7000 strokes/min untuk ukuran >200 mesh (wallas, 367)
Daya Motor : 2 HP untuk kapasitas < 8 ton/jam (Wallas, hal.365)
RESUME
Kode Screener (S-201)
Fungsi Alat untuk menyeragamkan ukuran precipitated silica
Jenis Vibrating Screening
Jumlah 1 buah
Diameter lubang ayakan 0.04 m
Luas ayakan 0.003 m2
Panjang sisi ayakan 0.05 m2
Daya Motor 2 HP
Getaran Screener 600-7000 strokes/min
an precipitated silica
Ball Mill (BM-201)
Fungsi : Mengecilkan ukuran padatan precipitated silica
Spesifikasi Alat
Fungsi : Menghaluskan Precipitated Silica menjadi 300 mesh
Kapasitas : 6944,44 kg/jam = 6,94 ton/jam = 166.56 ton/hari
Kode : BM - 01
Tipe : Denver Ball Mill Continous No. 200
Kapasitas Maksimal : 195 ton/hari
Kecepatan Putaran : 21 rpm
Ukuran : 8 x 6 ft
Power Max. : 67 hp (wallas, hal. 370)
Ball Charge : 20.2 ton
Efisensi : 97%
Jumlah : 1 unit
Sumber : Tabel 20.16 Perry ed 7th, hal 20-35
Silica menjadi 300 mesh
Gudang Penyimpanan Sekam Padi
Fungsi : Tempat Penyimpanan Bahan Baku Sekam Padi

Laju Alir Massa = 52461.82 Kg/jam


= 8813585.585 Kg/7 hari
Densitas Sekam Padi = 384 kg/m3
Waktu Penyimpanan = 7 hari

Rencana perbandingan gudang bahan baku


Panjang : Lebar 2=1
Panjang : Tinggi 2=1
Lebar : Tinggi 1=1

Laju alir volumetrik = 22952.0458 m3/7 hari


faktor kelonggaran = 50%
Volume Total Gedung = 34428.06869 m3
Volume = pxlxt
= 2t x t x t
= 2t3
2 t3 = 34428.06869 m3
t = 25.82027648 m
maka diperoleh :
tinggi gudang = 25.82 m
panjang gudang = 51.64 m
lebar gudang = 25.82 m
RESUME
Kode Gudang 1
Fungsi Tempat Penyimpanan Bahan Baku
Sekam Padi
Jumlah 1 gudang
Waktu penyimpanan 7 hari
Volume 34428.07 m3
Tinggi gudang 25.82 m
Panjang gudang 51.64 m
Lebar gudang 25.82 m
Tangki Penyimpanan H2SO4 60% (V-102)

Deskripsi
Fungsi : Menyimpan Larutan H2SO4 60%
Bentuk : Silinder dengan alas datar
Bahan Konstruksi : carbon steel SA-283 grade C
Jumlah : 1 unit
Waktu Penyimpana : 5 Hari = 120 jam
Jenis Head : Torispherical Dishead Head
Kondisi Operasi
P = 1 atm
T = 30 o
C
= 303.2 K
Komposisi Bahan
Komponen Massa(kg/jam) X ρ ( kg/m3) µ (cP)
H2SO4 60% 3829.02 0.4118 1826.97123 19.72
water 5469.20 0.5882 1023.01299 0.75
Total 9298.23 1 20.47
Densitas Campuran :1354.08 kg/m3
Viskositas Campuran : 8.56 cP
Volume bahan : 6.87 m3
Faktor Kelonggaran : 20% (Tabel 6, Timmerhaus, Hal 37)
Volume Cairan (Vc) = Qxt
= 6.87 x 120 jam
= 824.02 m3
= 29099.7 ft3
Volume Tangki (Vt) = 1.2 x 824.016 m3
= 988.82 m3
= 34919.6 ft3
= 261217 gal
Dirancang untuk dibagi menjadi 5 tangki, maka 197.764 m3= 52243.7 gal
Berdasarkan rule of thumb (walas,2012) untuk kapasitas melebihi 10.000 gal
menggunakan tangki dengan posisi vertikal. Dan dari buku Chemical Process
Equipment oleh stanley M.walas tabel 18.3 storage tank, underwriter API Standard
selected sizes dari Vt yang didapat maka diperoleh data sebagai berikut :
Volume Tangki = 52243.7 gal
Standard Volume = 81186 gal
Standad Height = 24 ft = 7.315 m
Standard Diameter = 24 ft = 7.315 m
Menghitung Diameter dan Tinggi Tangki menggunakan perhitungan
Perbandingan tinggi shell dengan diameter tangki 1 D
Syarat perbandingan tinggi shell dengan diameter adalah Hs:D < 2 (Ulrich, 1984)
Perbandingan tinggi tutup dengan diamater tangki direncanakan, T : D = 1 :4

a. Diameter Tangki
Volume tangki = V shell + V tutup
Volume shell (silinder)

Perbandingan Dt : Ht adal 1 Dt , maka Vt = 0.785 Dt3


Volume Tutup (torispherical)

maka, Volume tangki 1.045 D3


Dari persamaan tersebut, dapat diketahui diameter dan tinggi tangki
Dt = 32.20954 ft = 9.81759 m = 386.518 in
R = 16.10477 ft = 4.90879 m = 193.259 in
b. Tinggi Tangki
Tinggi tangki = Tinggi shell + Tinggi tutup
Tinggi shell = Ht 1 Dt, maka :
Ht = 32.2095 ft = 9.81759 m = 386.518 in
Tinggi Tutup
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)
Tinggi tutup 8.05238 ft = 2.4544 m = 96.6296 in
maka, Tinggi Tangki = 40.2619 ft = 12.272 m = 483.148 in

Design Tekanan dan Temperatur


a. Tekanan Operasi dan Tekanan Design
Tangki beroperasi pada tekanan atmosferik dan dalam menentukan tekanan
desain harus memperhatikan tekanan hidrostatis cairan didalam vessel.
Tekanan hidrostatis dapat dirumuskan dibawah ini :
Tinggi cairan dalam Tangk= 80% x Tinggi Tangki
= 9.81759 m
Tekanan Hidrostatis,
P = ρxgxl Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 0.588199 kg/m3x 9.8 m/s2 x 9.81759 m
= 56.59196 kg/m.s2
= 0.008 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi+ 0.008 Psi
= 14.7082 Psi

faktor keamanan tekanan 10% dari P design (walas, Hal 668)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 14.7082 Psi + 1.47082 Psi
= 16.179 Psi
= 1.48903 Psig

b. Temperatur Operasi dan Temperatur design


jika temperatur tangki (-20) - 650oF maka temperatur ditambahkan 50oF
(wallas, hal.668)
T operasi = 30 oC
= 86 oF
maka, T design = (86 + 50) oF
= 136 oF

Pemilihan Material
Material tangki yang akan digunakan adalah carbon steel SA - 283 grade C.
Pemilihan ini didasari atas pertimbangan bahan yang akan disimpan memiliki tingkat
korosi yang cukup tinggi, material dengan bahan tersebut memiliki ketahanan korosi
yang tinggi, mudah dalam pembuatannya dan tahan dalam range temperatur operasi.

Design Stress (S)


Untuk material SA-283 grade C yang bekerja pada temperatur 136oF
Tensil Strength 12650 Psi
S = 12650 Psi (Sumber : brownell and young hal 251)

Corrosion Allowance
Untuk mengantisipasi reaktan yang bersifat korosi,
diset corrosion allowance sebesar :
C = 0.015 in / year
(Sumber : timmerhaus hal 542)
Tebal Shell
Untuk mencari ketebalan silinder vessel (shell), digunakan persamaan berikut
(tabel 18.4 wallas hal 658)
Dimana, t = Ketebalan Shell (in)
P = Tekanan (Psi)
R = Jari-jari (in)
S = allowable stress (Psi)
E = Joint Efficiency (0,6-1)
C = Corrosion allowance (in)
(Wallas,2005)
Sehingga tebal sheel tangki diambil nilaE = 0.8 adalah
E=0.8 untuk single-welded butt joint with backing strip
(brown and young hal 253)

ts = 16.17903 Psi x 193.259 in + 0.015 in


( 12650 Psix 0.8 ) - ( 0.6 x 16.18 Psi)
ts = 0.324264 in
= 0.008236 m

Tekanan maksimum shell

(tabel 18.4 wallas hal 658)

P max = 16.963 psi

Tebal Head
Jenis Head yang diguakan adalah torispherical head.
Pertimbangan dalam pemilihan jenis head didasari atas
tekanan penyimpanan bahan 10-15 bar (coulson)
biaya pembentukan lebih murah (brownel & young,1959)

(tabel 18.4 wallas hal 658)

th = 0.309016 in
RESUME
Nama Tangki Larutan H2SO4 60%
Fungsi Menyimpan Larutan H2SO4 60%
Tipe Silinder tegak, flat bottom, torispherical roof dishead head
Bahan carbon steel SA-283 grade C
Jumlah 5 buah
Waktu Penyimpana 5 hari
Volume Tangki 197.76 m3
Diameter Tangki 9.82 m
Tinggi Silinder 9.82 m
Tinggi Head 2.45 m
Tebal Head 0.0078 m
Tebal Shell 0.0082 m
Tinggi Total 12.27 m
sitas melebihi 10.000 gal

k, underwriter API Standard

alah Hs:D < 2 (Ulrich, 1984)


rencanakan, T : D = 1 :4

alam menentukan tekanan


on steel SA - 283 grade C.
an disimpan memiliki tingkat
ut memiliki ketahanan korosi
am range temperatur operasi.

nakan persamaan berikut


Tangki Dissolver NaOH (V-103)

Deskripsi
Fungsi : tempat pengenceran NaOH dari konsenterasi 48% ke 4%
Bentuk : Silinder dengan alas datar
Bahan Konstruksi : carbon steel SA-283 grade C
Jumlah : 1 unit
Waktu Penyimpana : 1 Jam
Jenis Head : Torispherical
Kondisi Operasi
P = 1 atm
T = 30 o
C
= 303.2 K
Komponen Massa(kg/jam)
NaOH 48% 5492.50
water 40878.07
Total 46370.57

rate bahan = 46371 kg/jam


= 102229 lb/jam
densitas campura = 985.00 kg / m3 (hysys)
= 61.49 lb /ft3
Volume cairan = 1662.5 ft3/jam
= 47.077 m3/jam

Volume Tangki = 1.2 x 47.077 m3


= 56.4921 m3
= 1994.99 ft3
= 14923.5 gal

Berdasarkan rule of thumb (walas,2012) untuk kapasitas melebihi 10.000 gal


menggunakan tangki dengan posisi vertikal. Dan dari buku Chemical Process
Equipment oleh stanley M.walas tabel 18.3 storage tank, underwriter API Standard
selected sizes dari Vt yang didapat maka diperoleh data sebagai berikut :
Volume Tangki = 14923.5 gal
Standard Volume = 15000 gal
Standad Height = 39 ft = 11.89 m
Standard Diameter = 8 ft = 2.438 m

Menghitung Diameter dan Tinggi Tangki menggunakan perhitungan


Perbandingan tinggi shell dengan diameter tangki, 4.875 D
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4

a. Diameter Tangki
Volume tangki = V shell + V tutup
Volume shell (silinder)

Perbandingan Dt : Ht adal 4.875 Dt , maka Vt = 3.82688 Dt3


Volume Tutup (torispherical)

maka, Vt =4.086875 D3
Dari persamaan tersebut, dapat diketahui diameter dan tinggi tangki
Dt = 7.873774 ft = 2.39996 m = 94.4862 in
R = 3.936887 ft = 1.19998 m = 47.2431 in
b. Tinggi Tangki
Tinggi tangki = Tinggi shell + Tinggi tutup
Tinggi shell = Ht4.875 Dt
Ht = 38.3846 ft = 11.6998 m = 460.62 in
Tinggi Tutup
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)
Tinggi tutup 1.96844 ft =0.59999 m = 23.6216 in
maka, Tinggi Tangki = 40.3531 ft = 12.2998 m = 484.242 in

Design Tekanan dan Temperatur


a. Tekanan Operasi dan Tekanan Design
Tangki beroperasi pada tekanan atmosferik dan dalam menentukan tekanan
desain harus memperhatikan tekanan hidrostatis cairan didalam vessel.
Tekanan hidrostatis dapat dirumuskan dibawah ini :
Tinggi cairan dalam Tangk= 80% x Tinggi Tangki
= 9.83982 m
Tekanan Hidrostatis,
P = ρxgxl Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 985.00 kg/m3x 9.8 m/s2 x 9.83982 m
= 94983.76 kg/m.s2
= 13.77 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi+ 13.77 Psi
= 28.4726 Psi

faktor keamanan tekanan 10% dari P design (wallas, hal. 668)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 28.4726 Psi + 2.84726 Psi
= 31.3199 Psi
= 16.6299 Psig

b. Temperatur Operasi dan Temperatur design


jika temperatur tangki (-20) - 650oF maka temperatur ditambahkan 50oF
(wallas, hal.668)
T operasi = 30 oC
= 86 oF
maka, T design = (86 + 50) oF
= 136 oF

Pemilihan Material
Material tangki yang akan digunakan adalah carbon steel SA - 283 grade C.
Pemilihan ini didasari atas pertimbangan bahan yang akan disimpan memiliki tingkat
korosi yang cukup tinggi, material dengan bahan tersebut memiliki ketahanan korosi
yang tinggi, mudah dalam pembuatannya.

Design Stress (S)


Untuk material SA-283 grade C yang bekerja pada temperatur 136oF
Tensil Strength 12650 Psi
S = 12650 Psi (Sumber : brownell and young hal 251)

Corrosion Allowance
Untuk mengantisipasi reaktan yang bersifat korosi,
diset corrosion allowance sebesar 4 mm
C = 0.015 in / year
(Sumber : timmerhaus hal 542)
Tebal Shell
Untuk mencari ketebalan silinder vessel (shell), digunakan persamaan berikut
(tabel 18.4 wallas hal 658)
Dimana, t = Ketebalan Shell (in)
P = Tekanan (Psi)
R = Jari-jari (in)
S = allowable stress (Psi)
E = Joint Efficiency (0,6-1)
C = Corrosion allowance (in)
(Wallas,2005)
Sehingga tebal sheel tangki diambil nilaE = 0.8 adalah
E=0.8 untuk single-welded butt joint with backing strip
(brown and young hal 253)

ts = 31.31991 Psi x 47.2431 in + 0.015 in


( 12650 Psix 0.8 ) - ( 0.6 x 31.32 Psi)
ts = 0.161483 in
= 0.004102 m

Tekanan maksimum shell

(tabel 18.4 wallas hal 658)

P max = 34.5205 psi

Tebal Head
Jenis Head yang diguakan adalah torispherical head.
Pertimbangan dalam pemilihan jenis head didasari atas
tekanan penyimpanan bahan yang rendah (<=10 Psi),
biaya pembentukan lebih murah (brownel & young,1959)

(tabel 18.4 wallas hal 658)

th = 0.146256 in

h. Perhitungan Pengaduk
µ campuran (m) = 2.45 cp (hysys)
= 0.00164 lb/ft.sec
ρ campuran ( rho ) = 985.00 kg / m3
= 61.49 lb/ft3
Digunakan jenis pengaduk adalah 3 blade propeller agit(hal 156, Geankoplish)
dengan, Da/W = 5 (halaman 158, Geankoplish 4th)
Dt/J = 10
Untuk pengaduk secara umum :
Da/Dt = 03-0.5(halaman 158, Geankoplish 4th)
H/Dt = 1 (halaman 158, Geankoplish 4th)
C/Dt = 0.33 (halaman 158, Geankoplish 4th)
Dd/Da = 0.67 (halaman 158, Geankoplish 4th)
L/Da = 0.25 (halaman 158, Geankoplish 4th)
W/Da = 0.20 (halaman 158, Geankoplish 4th)
J/Dt = 0.10 (halaman 159, Geankoplish 4th)
Dimana :
Da = Diameter pengaduk
W = Lebar blade
Dt = Diameter tangki
J = Lebar Baffle
H = Tinggi cairan dalam tangki
C = Tinggi pengaduk dari dasar tangki
Dd = Panjang tangkai pengaduk
L = Panjang blade
digunakan diameter pengaduk : diameter tangDa/Dt 0.3
D pengaduk (Da)= 0.3 x 94.49 in
= 28.35 in 2.36 ft
Lebar Blade (W) = 0.2 Da
= 5.67 in 0.47 ft
Panjang Blade (L= 0.25 Da
= 7.09 in 0.59 ft
Tinggi Pengaduk = 0.33 x 94.49 in
dari dasar tanki = 31.18 in
= 2.60 ft
Panjang Tangkai = 0.67 Da
= 18.99 in
= 1.58 ft
i. Menentukan Jumlah Impeller
∑ impeller = tinggi cairan / diameter tangki
= 30.7077 ft
7.87 ft
= 3.9 impeller
= 1 impeller
j. Menentukan Daya Pengaduk(Wallas hal 292)
Daya untuk pengaduk = (1,5 hp / 1000 gal) x V
sehingga daya pengaduk yang akan digunakan :
V = 1662.48 ft3
= 2461.33 gal
P = 1.5 x 2461.33 gal
1000
= 3.69 hp
= 2030.6 lbf.ft/s
Effisiensi motor = 0.8
Daya motor = Pinput/effisiensi motor = 4.62 hp

k. Menentukan kecepatan pengaduk


Dari hal 292 wallas untuk pengadukan, tip speed 7,5-10 ft/detik
dipilih 10 ft/detik
rps = 10
π Da
= 1.35 rps
= 80.89 rpm

RESUME
Nama Dissolver NaOH
Kode V-103
Fungsi Mengencerkan NaOH dari konsenterasi 48% ke 3,75%
Tipe Silinder tegak, torispherical roof dishead head
Bahan Carbon Steel SA-283 grade C
Jumlah 1 buah
Volume tanki 56.5 m3
Diameter tanki 2.40 m
Tinggi silinder 11.70 m
Tinggi head 0.60 m
Tebal shell 0.004 m
Tinggi total 12.30 m
Jenis Pengaduk propeller
Jumlah Blade 3 blade
Jumlah impeller 1 impeller
Diameter pengaduk 0.72 m
Lebar Blade 0.14 m
Panjang Blade 0.18 m
Tinggi dari dasar ta 0.79 m
Panjang Tangkai 0.48 m
Daya Pengaduk 5.00 hp
Kecepatan Pengadu 80.89 rpm
konsenterasi 48% ke 4%

sitas melebihi 10.000 gal

k, underwriter API Standard


alam menentukan tekanan
on steel SA - 283 grade C.
an disimpan memiliki tingkat
ut memiliki ketahanan korosi

nakan persamaan berikut


Tangki Dissolver H2SO4 (V-104)

Deskripsi
Fungsi : Mengencerkan larutan Asam Sulfat dari 60% ke 11,4%
Bentuk : Silinder dengan alas datar
Bahan Konstruksi : carbon steel SA-283 grade C
Jumlah : 1 unit
Waktu Penyimpana : 1 Jam
Jenis Head : torispherical
Kondisi Operasi
P = 1 atm
T = 30 o
C
= 303.2 K
Komponen Massa(kg/jam) X ρ ( kg/m3) µ (cP)
H2SO4 60% 4298.17 0.46226 1826.97123 19.7219
water 5000.06 0.53774 1023.01299 0.75265
Total 9298.23 1 20.4745

ρ . X Volume (m3) µ . X rate bahan = 9298 kg/jam


844.53 2.35 9.12 = 20498.9 lb/jam
550.12 4.89 0.40 rho campuran = 1394.65 kg / m3
1394.65 7.24 9.52 = 87.07 lb /ft3
Volume cairan = 235.4 ft3/jam
= 6.667 m3/jam

Faktor Kelonggaran : 20% (Tabel 6, Timmerhaus, Hal 37)


Volume Tangki = 1.2 x 6.667 m3
= 8.0002 m3
= 282.523 ft3
= 2113.41 gal

Berdasarkan rule of thumb (walas,2012) untuk kapasitas melebihi 10.000 gal


menggunakan tangki dengan posisi vertikal. Dan dari buku Chemical Process
Equipment oleh stanley M.walas tabel 18.3 storage tank, underwriter API Standard
selected sizes dari Vt yang didapat maka diperoleh data sebagai berikut :
Volume Tangki = 2113.41 gal
Standard Volume = 5000 gal
Standad Height = 17 ft = 5.182 m
Standard Diameter = 7 ft = 2.134 m

Menghitung Diameter dan Tinggi Tangki menggunakan perhitungan


Perbandingan tinggi shell dengan diameter tangki, 2.429 D
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)

a. Diameter Tangki
Volume tangki = V shell + V tutup
Volume shell (silinder)

Perbandingan Dt : Ht adal 2.429 Dt , maka Vt = 1.91 Dt3


Volume Tutup (torispherical)

maka, Vt =2.166429 D3
Dari persamaan tersebut, dapat diketahui diameter dan tinggi tangki
Dt = 5.07 ft = 1.55 m = 60.85 in
R = 2.54 ft = 0.77 m = 30.43 in
b. Tinggi Tangki
Tinggi tangki = Tinggi shell + Tinggi tutup
Tinggi shell = Ht = 2,43 Dt, maka :
Ht = 12.32 ft = 3.75 m = 147.79 in
Tinggi Tutup
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)
Tinggi tutup 1.27 ft = 0.39 m = 15.21 in
maka, Tinggi Tangki = 13.58 ft = 4.14 m = 163.00 in

Design Tekanan dan Temperatur


a. Tekanan Operasi dan Tekanan Design
Tangki beroperasi pada tekanan atmosferik dan dalam menentukan tekanan
desain harus memperhatikan tekanan hidrostatis cairan didalam vessel.
Tekanan hidrostatis dapat dirumuskan dibawah ini :
Tinggi cairan dalam Tangk= 80% x Tinggi Tangki
= 3.31 m
Tekanan Hidrostatis,
P = ρxgxl Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 1394.65 kg/m3x 9.8 m/s2 x 3.3122 m
= 45269.65 kg/m.s2
= 6.564 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi+ 6.564 Psi
= 21.26 Psi

faktor keamanan tekanan 10% dari P design (wallas, Hal 668)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 21.26 Psi + 2.13 Psi
= 23.39 Psi
= 8.70 Psig

b. Temperatur Operasi dan Temperatur design


jika temperatur tangki (-20) - 650oF maka temperatur ditambahkan 50oF
(wallas, Hal 668)
T operasi = 30 oC
= 86 oF
maka, T design = (86 + 50) oF
= 136 oF

Pemilihan Material
Material tangki yang akan digunakan adalah carbon steel SA - 283 grade C.
Pemilihan ini didasari atas pertimbangan bahan yang akan disimpan memiliki tingkat
korosi yang cukup tinggi, material dengan bahan tersebut memiliki ketahanan korosi
yang tinggi, mudah dalam pembuatannya.

Design Stress (S)


Untuk material SA-283 grade C yang bekerja pada temperatur 136oF
Tensil Strength 12650 Psi
S = 12650 Psi (Sumber : brownell and young hal 251)

Corrosion Allowance
Untuk mengantisipasi reaktan yang bersifat korosi,
diset corrosion allowance sebesar 4 mm
C = 0.015 in / year
(Sumber : timmerhaus hal 542)
Tebal Shell
Untuk mencari ketebalan silinder vessel (shell), digunakan persamaan berikut
(tabel 18.4 wallas hal 658)
Dimana, t = Ketebalan Shell (in)
P = Tekanan (Psi)
R = Jari-jari (in)
S = allowable stress (Psi)
E = Joint Efficiency (0,6-1)
C = Corrosion allowance (in)
(Wallas,2005)
Sehingga tebal sheel tangki diambil nilaE = 0.8 adalah
E=0.8 untuk single-welded butt joint with backing strip
(brown and young hal 253)

ts = 23.39051 Psi x 30.427 in + 0.015 in


( 12650 Psix 0.8 ) - ( 0.6 x 23.39 Psi)
ts = 0.085424 in
= 0.00217 m

Tekanan maksimum shell

(tabel 18.4 wallas hal 658)

P max = 28.36 psi

Tebal Head
Jenis Head yang diguakan adalah torispherical head.
Pertimbangan dalam pemilihan jenis head didasari atas
tekanan penyimpanan bahan yang rendah (<=10 Psi),
biaya pembentukan lebih murah (brownel & young,1959)

(tabel 18.4 wallas hal 658)

th = 0.07 in

h. Perhitungan Pengaduk Nama


µ campuran (m) = 9.52 cp Kode
= 0.00640 lb/ft.sec Fungsi
ρ campuran ( rho ) = 1394.65 kg / m 3
Tipe
= 87.07 lb/ft 3

Digunakan jenis pengaduk adalah 3 blade propeller agit(hal 156, GeankoplishBahan


Jumlah
dengan, Da/W = 5 (halaman 158, Geankoplish 4thWaktu Penyimpanan
Dt/J = 10 Volume Tangki
Untuk pengaduk secara umum : Diameter Tangki
Da/Dt = 03-0.5(halaman 158, Geankoplish 4th) Tinggi Silinder
H/Dt = 1 (halaman 158, Geankoplish 4th) Tinggi Head
C/Dt = 0.33 (halaman 158, Geankoplish 4th) Tebal Head
Dd/Da = 0.67 (halaman 158, Geankoplish 4th) Tebal Shell
L/Da = 0.25 (halaman 158, Geankoplish 4th) Tinggi Total
W/Da = 0.20 (halaman 158, Geankoplish 4th)
J/Dt = 0.10 (halaman 159, Geankoplish 4th)
Dimana :
Da = Diameter pengaduk
W = Lebar blade
Dt = Diameter tangki
J = Lebar Baffle
H = Tinggi cairan dalam tangki
C = Tinggi pengaduk dari dasar tangki
Dd = Panjang tangkai pengaduk
L = Panjang blade
digunakan diameter pengaduk : diameter tangDa/Dt 0.3
D pengaduk (Da)= 0.3 x 60.85 in
= 18.26 in 1.52 ft
Lebar Blade (W) = 0.2 Da
= 3.65 in 0.30 ft
Panjang Blade (L= 0.25 Da
= 4.56 in 0.38 ft
Tinggi Pengaduk = 0.33 x 60.85 in
dari dasar tanki = 20.08 in
= 1.67 ft
Panjang Tangkai = 0.67 Da
= 12.23 in
= 1.02 ft
i. Menentukan Jumlah Impeller
∑ impeller = tinggi cairan / diameter tangki
= 9.8524 ft
5.07 ft
= 1.943 impeller
= 3 impeller
j. Menentukan Daya Pengaduk(Wallas hal 292)
Daya untuk pengaduk = (5 hp / 1000 gal) x V
sehingga daya pengaduk yang akan digunakan :
V = 235.44 ft3
= 348.57 gal
P = 5 x 348.57 gal
1000
= 1.74 hp
= 958.6 lbf.ft/s
Effisiensi motor = 0.8
Daya motor = Pinput/effisiensi motor = 2.18 hp

k. Menentukan kecepatan pengaduk


Dari hal 292 wallas untuk pengadukan, tip speed 15-20 ft/detik
dipilih 20 ft/detik
rps = 15
π Da
= 3.14 rps
= 188.4 rpm

RESUME
Nama Dissolver H2SO4
Kode V-104
Fungsi Mengencerkan H2SO4 dari konsenterasi 60% ke 11,4%
Tipe Silinder tegak, torispherical roof dishead head
Bahan Carbon Steel SA-283 grade C
Jumlah 1 buah
Volume tanki 8.0 m3
Diameter tanki 1.55 m
Tinggi silinder 3.75 m
Tinggi head 0.39 m
Tebal shell 0.0022 m
Tinggi total 4.14 m
Jenis Pengaduk propeller
Jumlah Blade 3 blade
Jumlah impeller 3 impeller
Diameter pengaduk 0.46 m
Lebar Blade 0.09 m
Panjang Blade 0.12 m
Tinggi dari dasar ta 0.20 m
Panjang Tangkai 0.31 m
Daya Pengaduk 3.00 hp
Kecepatan Pengadu 188.40 rpm
sitas melebihi 10.000 gal

k, underwriter API Standard


alam menentukan tekanan
on steel SA - 283 grade C.
an disimpan memiliki tingkat
ut memiliki ketahanan korosi

nakan persamaan berikut


Nama Tangki Larutan H2SO4 60%
Kode
Fungsi Menyimpan Larutan H2SO4 60%
Tipe Silinder tegak, flat bottom, torispheric

Bahan carbon steel SA-283 grade C


Jumlah 1
Waktu Penyimpanan 1
Volume Tangki 8.0001955131
Diameter Tangki 1.5456929952
Tinggi Silinder 3.7538258455
Tinggi Head 0.3864232488
Tebal Head 0.0017867011
Tebal Shell 0.0021697732
Tinggi Total 4.1402490943
RESUME (T-102)
Tangki Larutan H2SO4 60%

Menyimpan Larutan H2SO4 60%


Silinder tegak, flat bottom, torispherical roof dishead head

carbon steel SA-283 grade C


buah
hari
8.0001955131 m3
1.5456929952 m
3.7538258455 m
0.3864232488 m
0.0017867011 m
0.0021697732 m
4.1402490943 m
-102)
Tangki Penyimpanan NaOH 48% (V-101)

Deskripsi
Fungsi : Menyimpan Larutan NaOH 48%
Bentuk : Silinder dengan alas datar
Bahan Konstruksi : carbon steel SA-283 grade C
Jumlah : 1 unit
Waktu Penyimpana : 5 Hari
Jenis Head : Torispherical Dishead Head

Kondisi Operasi
P = 1 atm
T = 30 oC
= 303.2 K
Komposisi Bahan
Komponen Masa(kg/jam) densitas campuran = 985 kg/m3
NaOH 48% 3691.09 = 61.49 lb/ft3
water 1801.41
Total 5492.50

Faktor Kelonggaran : 20% (Tabel 6, Timmerhaus, Hal 37)


Volume Cairan (Vc) = Qxt
= 5.57614 x 120 jam
= 669.137 m3
= 23630.2 ft3

Volume Tangki (Vt) = 1.2 x 669.137 m3


= 802.964 m3
= 28356.3 ft3
= 212119 gal
Dirancang untuk dibagi menjadi 5 tangki, maka 160.593 m3= 42424.1 gal
Berdasarkan rule of thumb (walas,2012) untuk kapasitas melebihi 10.000 gal
menggunakan tangki dengan posisi vertikal. Dan dari buku Chemical Process
Equipment oleh stanley M.walas tabel 18.3 storage tank, underwriter API Standard
selected sizes dari Vt yang didapat maka diperoleh data sebagai berikut :
Volume Tangki = 42424.1 gal
Standard Volume = 46788 gal
Standad Height = 18 ft = 5.486 m
Standard Diameter = 21 ft = 6.401 m

Menghitung Diameter dan Tinggi Tangki menggunakan perhitungan


Perbandingan tinggi shell dengan diameter tangki, 0.857 D
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)

a. Diameter Tangki
Volume tangki = V shell + V tutup
Volume shell (silinder)

Perbandingan Dt : Ht adal 0.857 Dt , maka Vt = 0.67286 Dt3


Volume Tutup (torispherical)

maka, Vt =0.932857 D3
Dari persamaan tersebut, dapat diketahui diameter dan tinggi tangki
Dt = 31.20886 ft = 9.51258 m = 374.51 in
R = 15.60443 ft = 4.75629 m = 187.255 in
b. Tinggi Tangki
Tinggi tangki = Tinggi shell + Tinggi tutup
Tinggi shell = Ht0.857 Dt, maka :
Ht = 26.7505 ft = 8.15364 m = 321.009 in
Tinggi Tutup
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)
Tinggi tutup 7.80222 ft =2.37814 m = 93.6275 in
maka, Tinggi Tangki = 34.5527 ft = 10.5318 m = 414.636 in

Design Tekanan dan Temperatur


a. Tekanan Operasi dan Tekanan Design
Tangki beroperasi pada tekanan atmosferik dan dalam menentukan tekanan
desain harus memperhatikan tekanan hidrostatis cairan didalam vessel.
Tekanan hidrostatis dapat dirumuskan dibawah ini :
Tinggi cairan dalam Tangk= 80% x Tinggi Tangki
= 8.42543 m
Tekanan Hidrostatis,
P = ρxgxl Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 985 kg/m3x 9.8 m/s2 x 8.42543 m
= 81330.63 kg/m.s2
= 11.79 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi+ 11.79 Psi
= 26.4929 Psi

faktor keamanan tekanan 10% dari P design (wallas, 668)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 26.4929 Psi + 2.64929 Psi
= 29.1422 Psi
= 14.4522 Psig

b. Temperatur Operasi dan Temperatur design


jika temperatur tangki (-20) - 650oF maka temperatur ditambahkan 50oF
(wallas,668)
T operasi = 30 oC
= 86 oF
maka, T design = (86 + 50) oF
= 136 oF

Pemilihan Material
Material tangki yang akan digunakan adalah carbon steel SA - 283 grade C.
Pemilihan ini didasari atas pertimbangan bahan yang akan disimpan memiliki tingkat
korosi yang cukup tinggi, material dengan bahan tersebut memiliki ketahanan korosi
yang tinggi, mudah dalam pembuatannya.

Design Stress (S)


Untuk material SA-283 grade C yang bekerja pada temperatur 136oF
Tensil Strength 12650 Psi
S = 12650 Psi (Sumber : brownell and young hal 251)

Corrosion Allowance
Untuk mengantisipasi reaktan yang bersifat korosi,
diset corrosion allowance sebesar 4 mm
C = 0.015 in / year
(Sumber : timmerhaus hal 542)
Tebal Shell
Untuk mencari ketebalan silinder vessel (shell), digunakan persamaan berikut
(tabel 18.4 wallas hal 658)
Dimana, t = Ketebalan Shell (in)
P = Tekanan (Psi)
R = Jari-jari (in)
S = allowable stress (Psi)
E = Joint Efficiency (0,6-1)
C = Corrosion allowance (in)
(Wallas,2005)
Sehingga tebal sheel tangki diambil nilaE = 0.8 adalah
E=0.8 untuk single-welded butt joint with backing strip
(brown and young hal 253)

ts = 29.14224 Psi x 187.255 in + 0.015 in


( 12650 Psix 0.8 ) - ( 0.6 x 29.14 Psi)
ts = 0.555166 in
= 0.014101 m

Tekanan maksimum shell

(tabel 18.4 wallas hal 658)

P max = 29.9501 psi

Tebal Head
Jenis Head yang diguakan adalah torispherical head.
Pertimbangan dalam pemilihan jenis head didasari atas
biaya pembentukan lebih murah (brownel & young,1959)

(tabel 18.4 wallas hal 658)

th = 0.539388 in
RESUME
Nama Tangki Larutan NaOH 48%
Kode V-101
Fungsi Menyimpan Larutan NaOH 48%
Tipe Silinder tegak, flat bottom, torispherical roof dishead head

Bahan carbon steel SA-283 grade C


Jumlah 5 buah
Waktu Penyimpana 5 hari
Volume Tangki 160.59 m3
Diameter Tangki 9.51 m
Tinggi Silinder 8.15 m
Tinggi Head 2.38 m
Tebal Head 0.01 m
Tebal Shell 0.01 m
Tinggi Total 10.53 m
sitas melebihi 10.000 gal

k, underwriter API Standard


alam menentukan tekanan
on steel SA - 283 grade C.
an disimpan memiliki tingkat
ut memiliki ketahanan korosi

nakan persamaan berikut


Hopper (V-205)
Fungsi = Menampung precipitated silica untuk 1/2 hari
sebelum masuk rotary dryer
Bentuk = Silinder tegak dengan tutup bawah berbentuk konical
bersudut 120°
Bahan Konstruksi = Carbon Steel 238 Grade C
Jumlah = 1 buah
Kondisi = 92,8oC 1 atm
densitas SiO2 = 3139.89 Kg/m3
Laju alir m = 14,660.94 Kg/jam
Laju alir V = 4.67 m3/jam
Waktu tinggal = 0.5 hari 12 jam
Volume SiO2 = rate massa masuk x waktu tinggal
r SiO2
Volume SiO2 = 56.03 m3
Faktor Safety = 20%
Volume Hopper = 67.24 m3

Diameter dan tinggi shell


Direncanakan :
Tinggi shell = diameter (Hs : D = 3 : 2 ) Brownell & Young,
Tinggi Head = diameter (Hh : D = 1 : 4 ) 1959
Volume Shell tangki (Vs)
Vs = 1/4 𝜋 𝐷_(𝑖 )
^2 𝐻
Vs = 3/8 𝜋 𝐷^3
Didapat dari perbandingan Tinggi shell

Vs = 1.18 D3

Volume Konikal (Vh)


Vh = 𝜋/(24 tan 〖 (𝑜,5 Peters,
� 〗 )) 𝐷^3 et.al.,
2004
= 0.08 D3

Volume tangki (V)


1 m= 3.28 ft
V= Vs + Vh
= 1.3 D3
67.2 = 1.3 D3
D3 = 53.66 m3
D= 3.77 m = 12.38 ft
Hs = 5.66 m = 18.56 ft
Volume Shell tangki (Vs)= 63.18 m3
Volume Konikal (Vh) = 4.05 m3
Volume Solid dalam koni= 4.05 m3
Volume Solid dalam shel= Volume SiO2 - Volume Solid dalam konis
Volume Solid dalam shel= 51.98 m3
Tinggi konikal (hc) = tg 0.5 a (D-m) (Hense, hal 92, pers. 4-17)
2
Dimana : D = diameter shell
m = diameter flat spot = 0.21 ft

Tinggi konikal (hc) = 1.95 ft = 0.59 m


Tinggi Solid dalam shell = vol solid dalam shell /(p/4 x D ) 2

= 4.65 m = 15.27 ft
inggi Solid dalam tangki = Tinggi Solid dalam shell + Tinggi Konikal
= 5.2477 m = 17.21763707 ft

Menentukan tekanan design


Tekanan hidrostatik : 1 psia = 6.89E+03 kg/m.s2
P = 𝜌𝑥𝑔𝑥�
P = 2000 kg/m3 x 9,8 m/S2 x 3,3503 m
P= 161475.94 kg/m.s2
= 23.42 Psia
faktor Safety = 10% (wallas, 668)
Tekanan udara luar = 1 atm 14.696 Psia
Maka : 1 Psia = 6.89 Kpa
Pdesign = (1 + 0,1) (14,696 + 30,4515)
= 41.93 Psi = 289.08 Kpa

Joint efficiency ( E ) = 0.85 (Brownell & Young, page 347)


Alowable stress (S) = 12650 Psia = 87218.71 Kpa
Faktor korosi (Ca) = 0,015 in/tahun (timmerhaus hal 542)
= 0.015 in = 0.0004 m
1m = 39.37 in
Tebal shell tangki : cylindrical
t = 𝑃𝐷/(2 𝑆𝐸 −1,2 𝑃)+ Ca Peters, et.al.,
2004

t= 232,8453 kpa x 2,7179 m +0,015


2(112039,85 kpa x 0,85) - 1,2(232,8453 kpa)
t= 0.008 m = 0.305 in

Tebal tutup tangki Conical (120 o)

Peters,
t =𝑃𝐷/(2 cos 〖 (0,5 �) 〗 (𝑆𝐸 −0,6 𝑃)) + Ca et.al.,
2004

t= 0.015 m = 0.60 in

RESUME
Nama Hopper Precipitated Silica
Kode V-205
Fungsi Menyimpan Padatan Silica sebelum ke Ballmill
Tipe bersudut 120°
Bahan 1 buah
Jumlah 1 buah
Waktu Penyimpanan 0.5 hari
Volume Hopper 67.24 m3
Diameter Hopper 3.77 m
Tinggi Silinder 5.66 m
Tinggi Konikal 0 0.59 m
Tebal Konikal 0 0.02 m
Tebal Shell 0.01 m
Tinggi Total 0 6.25 m
awah berbentuk konical

perbandingan Tinggi shell


Hense, hal 92, pers. 4-17)

(timmerhaus hal 542)


= #REF! m
= #REF! m

#REF! D
Hopper (V-206)
Fungsi = Menampung precipitated silica untuk 1/2 hari
sebelum masuk ball mill
Bentuk = Silinder tegak dengan tutup bawah berbentuk konical
bersudut 120°
Bahan Konstruksi = Carbon Steel 238 Grade C
Jumlah = 1 buah
Kondisi = 30oC 1 atm
densitas SiO2 = 3139.89 Kg/m3
Laju alir m = 6,944.44 Kg/jam
Laju alir V = 2.2116826 m3/jam
Waktu tinggal = 0.5 hari 12 jam
Volume SiO2 = rate massa masuk x waktu tinggal
r SiO2
Volume SiO2 = 26.540191 m3
Faktor Safety = 20%
Volume Hopper = 31.848229 m3

Diameter dan tinggi shell


Direncanakan :
Tinggi shell = diameter (Hs : D = 3 : 2 ) Brownell & Young, 1959
Tinggi Head = diameter (Hh : D = 1 : 4 )
Volume Shell tangki (Vs)
Vs = 1/4 𝜋 𝐷_(𝑖 )
^2 𝐻
Vs = 3/8 𝜋 𝐷^3
Didapat dari perbandingan Tinggi shell

Vs = 1.1775 D3

Volume Konikal (Vh)


Vh = 𝜋/(24 tan 〖 (𝑜,5 Peters, et.al.,
� 〗 )) 𝐷^3 2004
= 0.4088026 D3

Volume tangki (V)


1 m= 3.281 ft
V = Vs + Vh
= 1.5863 D3
31.8482 = 1.5863 D3
D3 = 20.0770 m3
D= 2.7179 m = 8.9174 ft
Hs = 4.0768 m = 13.3761 ft
Volume Shell tangki (Vs) = 23.6407 m3
Volume Konikal (Vh) = 8.2075 m3
Volume Solid dalam koni= 8.2075 m3
Volume Solid dalam shell= Volume SiO2 - Volume Solid dalam konis
Volume Solid dalam shell= 18.3327 m3
Tinggi konikal (hc) = tg 0.5 a (D-m) (Hense, hal 92, pers. 4-17)
2
Dimana : D = diameter shell
m = diameter flat spot = 0.208 ft

Tinggi konikal (hc) = 1.3937 ft = 0.424773971 m


Tinggi Solid dalam shell = vol solid dalam shell /(p/4 x D2)
= 3.1615 m = 10.37279337 ft
inggi Solid dalam tangki = Tinggi Solid dalam shell + Tinggi Konikal
= 3.5862 m = 11.76647677 ft

Menentukan tekanan design


Tekanan hidrostatik : 1 psia = 6.89E+03 kg/m.s2
P = 𝜌𝑥𝑔𝑥�
P = 2000 kg/m3 x 9,8 m/S2 x 3,3503 m
P = 110352.13 kg/m.s2
= 16.0052 Psia
faktor Safety = 10% (Coulson, 807)
Tekanan udara luar = 1 atm 14.696 Psia
Maka : 1 Psia = 6.89476 Kpa
Pdesign = (1 + 0,1) (14,696 + 30,4515)
= 33.7713 Psi = 232.8453 Kpa

Joint efficiency ( E ) = 0.85 (Brownell & Young, page 347)


Alowable stress (S) = 12650 Psia = 87218.71 Kpa
Faktor korosi (Ca) = 0,015 in/tahun (timmerhaus hal 542)
= 0.015 in = 0.0004 m
1m = 39.37 in

Tebal shell tangki : cylindrical


t = 𝑃𝐷/(2 𝑆𝐸 −1,2 𝑃)+ Ca
Peters, et.al.,
2004
t= 232,8453 kpa x 2,7179 m
+0,015
2(112039,85 kpa x 0,85) - 1,2(232,8453 kpa)
t= 0.0047 m = 0.1834 in

Tebal tutup tangki Conical (120 o)

t =𝑃𝐷/(2 cos 〖 (0,5 �) 〗 (𝑆𝐸 −0,6 Peters,


𝑃)) + Caet.al., 2004

t = 0.0085525 m = 0.33671032 in

RESUME
Nama Hopper Precipitated Silica
Kode V-206
Fungsi Menyimpan Padatan Precipitated Silica sebelum ke Ballmill
Tipe Silinder tegak dengan tutup bawah berbentuk konical
Bahan Carbon Steel 238 Grade C
Jumlah 1 buah
Waktu Penyimpanan 0.5 hari
Volume Hopper 31.85 m3
Diameter Hopper 2.72 m
Tinggi Silinder 4.08 m
Tinggi Konikal 0 0.42 m
Tebal Konikal 0 0.009 m
Tebal Shell 0 0.005 m
Tinggi Total 0 4.50 m
bawah berbentuk konical
ted Silica sebelum ke Ballmill
= #REF! m
= #REF! m

#REF! D
Silo (V-307)
Fungsi = Menampung produk akhir precipitated silica

Bentuk = Silinder tegak dengan tutup bawah berbentuk konical


bersudut 120°
Bahan Konstruksi = Carbon Steel SA 283 grade C
Jumlah = 1 buah
Kondisi = 30oC 1 atm
densitas SiO2 = 3139.89 Kg/m3
Laju alir m = 6,944.44 Kg/jam
Laju alir V = 2.2116826 m3/jam
Waktu tinggal = 7 hari 168 jam
Volume SiO2 = rate massa masuk x waktu tinggal
r SiO2
Volume SiO2 = 371.56267 m3
Faktor Safety = 20%
Volume Hopper = 445.87521 m3

Diameter dan tinggi shell


Direncanakan :
Tinggi shell = diameter (Hs : D = 3 : 2 ) Brownell & Young, 1959
Tinggi Head = diameter (Hh : D = 1 : 4 )
Volume Shell tangki (Vs)
Vs = 1/4 𝜋 𝐷_(𝑖 )
^2 𝐻
Vs = 3/8 𝜋 𝐷^3
Didapat dari perbandingan Tinggi shell

Vs = 1.1775 D3

Volume Konikal (Vh)


Vh = 𝜋/(24 tan 〖 (𝑜,5 Peters, et.al.,
� 〗 )) 𝐷^3 2004
= 0.4088026 D3

Volume tangki (V)


1 m= 3.281 ft
V = Vs + Vh
= 1.5863 D3
445.8752 = 1.5863 D3
D3 = 281.0783 m3
D= 6.5505 m = 21.4923 ft
Hs = 9.8258 m = 32.2384 ft
Volume Shell tangki (Vs) = 330.9697 m3
Volume Konikal (Vh) = 114.9055 m3
Volume Solid dalam koni= 114.9055 m3
Volume Solid dalam shell= Volume SiO2 - Volume Solid dalam konis
Volume Solid dalam shell= 256.6571 m3
Tinggi konikal (hc) = tg 0.5 a (D-m) (Hense, hal 92, pers. 4-17)
2
Dimana : D = diameter shell
m = diameter flat spot = 0.208 ft

Tinggi konikal (hc) = 3.4059 ft = 1.038070929 m


Tinggi Solid dalam shell = vol solid dalam shell /(p/4 x D2)
= 7.6196 m = 24.9999077 ft
inggi Solid dalam tangki = Tinggi Solid dalam shell + Tinggi Konikal
= 8.6577 m = 28.40581842 ft

Menentukan tekanan design


Tekanan hidrostatik : 1 psia = 6.89E+03 kg/m.s2
P = 𝜌𝑥𝑔𝑥�
P = 2000 kg/m3 x 9,8 m/S2 x 3,3503 m
P = 266404.52 kg/m.s2
= 38.6387 Psia
faktor Safety = 10% (Coulson, 807)
Tekanan udara luar = 1 atm 14.696 Psia
Maka : 1 Psia = 6.89476 Kpa
Pdesign = (1 + 0,1) (14,696 + 30,4515)
= 58.6682 Psi = 404.5029 Kpa

Joint efficiency ( E ) = 0.85 (Brownell & Young, page 347)


Alowable stress (S) = 12650 Psia = 87218.71 Kpa
Faktor korosi (Ca) = 0,015 in/tahun (timmerhaus hal 542)
= 0.015 in = 0.0004 m
1m = 39.37 in

Tebal shell tangki : cylindrical


t = 𝑃𝐷/(2 𝑆𝐸 −1,2 𝑃)+ Ca
Peters, et.al.,
2004
t= 232,8453 kpa x 2,7179 m
+0,015
2(112039,85 kpa x 0,85) - 1,2(232,8453 kpa)
t= 0.0183 m = 0.7209 in

Tebal tutup tangki Conical (120 o)

t =𝑃𝐷/(2 cos 〖 (0,5 �) 〗 (𝑆𝐸 −0,6 Peters,


𝑃)) + Caet.al., 2004

t = 0.0358586 m = 1.411751406 in

RESUME
Nama Silo Precipitated Silica
Kode V-307
Fungsi Menyimpan Padatan Precipitated Silica akhir
Tipe Silinder tegak dengan tutup bawah berbentuk konical
Bahan Carbon Steel SA 283 grade C
Jumlah 1 buah
Waktu Penyimpanan 7 hari
Volume Hopper 445.88 m3
Diameter Hopper 6.55 m
Tinggi Silinder 9.83 m
Tinggi Konikal 0 1.04 m
Tebal Konikal 0 0.04 m
Tebal Shell 0 0.02 m
Tinggi Total 0 10.86 m
bawah berbentuk konical
= #REF! m
= #REF! m

#REF! D
Blower (BL-01)
Fungsi : Menghembuskan udara dari lingkungan ke rotary kiln
Tipe : Centrifugal Blower
Suhu Udara : 30 o
C
Tekanan in : 14.7 psia
∆P : 0.5 psi 13.866 inH2O (Perry, Tabel 10-12)
Tekanan out : 14.7 psia
Laju Udara = 260,032 kg/jam
Densitas = 1.1676 kg/m3
Volumetrik = 222706.1 m3/jam
= 3711.769 m3/menit
= 131077.4 ft3/menit
Daya yang dibutuhkan untuk menggerakkan poros motor :
HP = 1.57x10-4 x Q x DP
HP = 285 hp
Efisiensi = HP blower/ HP poros
Efisiensi blower 40% - 70% (Perry, hal 10-46)
Dipakai 70%
HP Poros = 200 hp

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


lingkungan ke rotary kiln

H2O (Perry, Tabel 10-12)

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


PREHEATER (E-101)
Fungsi : Memanaskan NaOH sebelum masuk ke reaktor Sodium Silikat
INPUT
Aliran Massa X Rho Rho.X Cp (J/g K)
NaOH 3690.17 0.08 5477.12 436.32 435.58
H2O 42632.11 0.92 1023.01 941.52 377.49
Total 46322.28 1 1377.84

OUTPUT
Aliran Massa X Rho Rho. X Cp (J/g K)
NaOH 3690.17 0.08 1851.65 147.51 11905.91
H2O 42632.11 0.92 889.77 818.89 10409.19
Air 4680.61 1 966.39

Fluida Dingin
Massa = 46,322.28 kg/jam = 102123.7
T in = 30 C = 86
T out = 162 C = 323.6
Tave = 204.8 F
Tchange = 237.6 F
Cp = 382.11 J/gK
= 91.33 btu/lb F
k = 0.30743899 btu/hr ft F
Fluida Panas (udara dari rotary kiln)
Massa = 302,971.67 kg/jam = 667941.68
T in = 800 C = 1472
T out = 736.12 C = 1357.0123
Tave = 1414.50617 F
Tchange = 114.987664 F
Cp = 28136.60 J/gK
= 6721.83 btu/lb F
k = 2613344.47 btu/hr ft F
Jenis heat exchanger = Floating head 1-2 heat exchanger
∆𝑃�= (� 〖𝐺�〗 ^2 𝐷�(𝑁+1))/(5.22 ∗ 〖 10 〗 ^10 𝐷𝑒� ∅�)

∆𝑃�=(� 〖𝐺�〗 ^2 𝐿𝑛)/(5.22 ∗10^10∗𝐷�∅𝑖)

𝑉^2/2𝑔′

∆ Pr 〖 =(4𝑛𝑉^2)/(� 2𝑔′) 〗
𝑈�=(ℎ𝑖𝑜 ∗ℎ𝑜)/((ℎ𝑖𝑜+ℎ𝑜))

𝑅�=(𝑈�−𝑈�)/(𝑈�∗𝑈�)
𝑄 �𝑜��=𝑄 ℎ𝑜�
𝑤 𝑥 𝐶𝑝� 𝑥 ∆𝑇�=𝑊 𝑥 𝐶𝑝ℎ 𝑥 ∆𝑇ℎ

𝐿𝑀𝑇𝐷=((𝑇_ℎ1−𝑇_�2 )−(𝑇_ℎ2−𝑇_�1))/(�𝑛 ((𝑇_ℎ1−𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))


𝑅=(𝑇_ℎ1−𝑇_ℎ2)/(𝑇_�2−𝑇_�1 )

𝑆=(𝑇_�2−𝑇_�1)/(𝑇_ℎ1−𝑇_�1 )
�=𝑄/(𝑈� 𝑥 �𝑇�𝑚��)

𝑁�=�/(𝐿. �𝑜)
�_�=𝐼𝐷 ∗(𝐶^′ 𝐵)/144 𝑃𝑇

𝐺�=𝑤/�_�

Re = De x Gs /µ
(�� 〖 /𝑘) 〗 ^(1/2)

ℎ𝑜= 𝐽_𝐻 ∗ 𝑘/𝐷𝑒∗(��/𝑘 )^(1/2)∗∅_�

�^′ �=𝜋∗(𝑂𝐷^2)/4

��=𝑁� ∗(�^′ �)/144𝑛

𝐺�=𝑤/��

𝑅𝑒=𝐷∗𝐺�/�
(�� 〖 /𝑘)
〗 ^(1/2)

ℎ𝑖=𝐽_𝐻∗𝑘/𝐷∗(��/𝑘 )^(1/2) ∗ ∅�

ℎ𝑖𝑜/(∅𝑖)=ℎ𝑖/(∅𝑖) ∗𝐼𝐷/𝑂𝐷

∆𝑃�= (� 〖𝐺�〗 ^2 𝐷�(𝑁+1))/(5.22 ∗ 〖 10 〗 ^10 𝐷𝑒�


∅�)

∆𝑃�=(� 〖𝐺�〗 ^2 𝐿𝑛)/(5.22 ∗10^10∗𝐷�∅𝑖)


∆𝑃�=(� 〖𝐺�〗 ^2 𝐿𝑛)/(5.22 ∗10^10∗𝐷�∅𝑖)

𝑉^2/2𝑔′

∆ Pr 〖 =(4𝑛𝑉^2)/(� 2𝑔′) 〗

𝑈�=(ℎ𝑖𝑜 ∗ℎ𝑜)/((ℎ𝑖𝑜+ℎ𝑜))

𝑅�=(𝑈�−𝑈�)/(𝑈�∗𝑈�)
𝑄 �𝑜��=𝑄 ℎ𝑜�
𝑤 𝑥 𝐶𝑝� 𝑥 ∆𝑇�=𝑊 𝑥 𝐶𝑝ℎ 𝑥 ∆𝑇ℎ
𝐿𝑀𝑇𝐷=((𝑇_ℎ1−𝑇_�2 )−(𝑇_ℎ2−𝑇_�1))/(�𝑛 ((𝑇_ℎ1−𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))

𝑅=(𝑇_ℎ1−𝑇_ℎ2)/(𝑇_�2−𝑇_�1 )

𝑆=(𝑇_�2−𝑇_�1)/(𝑇_ℎ1−𝑇_�1 )

�=𝑄/(𝑈� 𝑥
�𝑇�𝑚��)
𝑁�=�/(𝐿. �𝑜)

�_�=𝐼𝐷 ∗(𝐶^′ 𝐵)/144 𝑃𝑇


𝐺�=𝑤/�_�

Re = De x Gs /µ

(�� 〖 /𝑘) 〗 ^(1/2)

ℎ𝑜= 𝐽_𝐻 ∗ 𝑘/𝐷𝑒∗(��/𝑘 )^(1/2)∗∅_�

�^′ �=𝜋∗(𝑂𝐷^2)/4

��=𝑁� ∗(�^′ �)/144𝑛


𝐺�=𝑤/��

𝑅𝑒=𝐷∗𝐺�/�

(�� 〖 /𝑘) 〗 ^(1/2)

ℎ𝑖=𝐽_𝐻∗𝑘/𝐷∗(��/𝑘 )^(1/2) ∗ ∅�

ℎ𝑖𝑜/(∅𝑖)=ℎ𝑖/(∅𝑖) ∗𝐼𝐷/𝑂𝐷
∆𝑃�= (� 〖𝐺�〗 ^2 𝐷�(𝑁+1))/(5.22 ∗ 〖 10 〗 ^10 𝐷𝑒� ∅�)

∆𝑃�=(� 〖𝐺�〗 ^2 𝐿𝑛)/(5.22 ∗10^10∗𝐷�∅𝑖)

𝑉^2/2𝑔′
∆ Pr 〖 =(4𝑛𝑉^2)/(� 2𝑔′) 〗

𝑈�=(ℎ𝑖𝑜 ∗ℎ𝑜)/((ℎ𝑖𝑜+ℎ𝑜))

𝑅�=(𝑈�−𝑈�)/(𝑈�∗𝑈�)
𝑄 �𝑜��=𝑄 ℎ𝑜�
𝑤 𝑥 𝐶𝑝� 𝑥 ∆𝑇�=𝑊 𝑥 𝐶𝑝ℎ 𝑥 ∆𝑇ℎ

𝐿𝑀𝑇𝐷=((𝑇_ℎ1−𝑇_�2 )−(𝑇_ℎ2−𝑇_�1))/(�𝑛 ((𝑇_ℎ1−𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))

𝑅=(𝑇_ℎ1−𝑇_ℎ2)/(𝑇_�2−𝑇_�1 )

𝑆=(𝑇_�2−𝑇_�1)/(𝑇_ℎ1−𝑇_�1 )
�=𝑄/(𝑈� 𝑥
�𝑇�𝑚��)

𝑁�=�/(𝐿. �𝑜)
�_�=𝐼𝐷 ∗(𝐶^′ 𝐵)/144 𝑃𝑇

𝐺�=𝑤/�_�

Re = De x Gs /µ

(�� 〖 /𝑘) 〗 ^(1/2


)
(�� 〖 /𝑘) 〗 ^(1/2
)
ℎ𝑜= 𝐽_𝐻 ∗ 𝑘/𝐷𝑒∗(��/𝑘 )^(1/2)∗∅_�

�^′ �=𝜋∗(𝑂𝐷^2)/4

��=𝑁� ∗(�^′ �)/144𝑛

𝐺�=𝑤/��

𝑅𝑒=𝐷∗𝐺�/�

(�� 〖 /𝑘) 〗 ^(1/2)

ℎ𝑖=𝐽_𝐻∗𝑘/𝐷∗(��/𝑘 )^(1/2) ∗ ∅�
ℎ𝑖𝑜/(∅𝑖)=ℎ𝑖/(∅𝑖) ∗𝐼𝐷/𝑂𝐷

∆𝑃�= (� 〖𝐺�〗 ^2 𝐷�(𝑁+1))/(5.22 ∗ 〖 10 〗 ^10 𝐷𝑒�


∅�)

∆𝑃�=(� 〖𝐺�〗 ^2 𝐿𝑛)/(5.22 ∗10^10∗𝐷�∅𝑖)

𝑉^2/2𝑔′

∆ Pr 〖 =(4𝑛𝑉^2)/(� 2𝑔′) 〗
𝑈�=(ℎ𝑖𝑜 ∗ℎ𝑜)/((ℎ𝑖𝑜+ℎ𝑜))

𝑅�=(𝑈�−𝑈�)/(𝑈�∗𝑈�)
𝑄 �𝑜��=𝑄 ℎ𝑜�
𝑤 𝑥 𝐶𝑝� 𝑥 ∆𝑇�=𝑊 𝑥 𝐶𝑝ℎ 𝑥 ∆𝑇ℎ

𝐿𝑀𝑇𝐷=((𝑇_ℎ1−𝑇_�2 )−(𝑇_ℎ2−𝑇_�1))/(�𝑛 ((𝑇_ℎ1−𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))

𝑅=(𝑇_ℎ1−𝑇_ℎ2)/(𝑇_�2−𝑇_�1 )
𝑆=(𝑇_�2−𝑇_�1)/(𝑇_ℎ1−𝑇_�1 )
�=𝑄/(𝑈� 𝑥
�𝑇�𝑚��)

𝑁�=�/(𝐿. �𝑜)
�_�=𝐼𝐷 ∗(𝐶^′ 𝐵)/144 𝑃𝑇

𝐺�=𝑤/�_�

Re = De x Gs /µ

(�� 〖 /𝑘) 〗 ^(1/2)

ℎ𝑜= 𝐽_𝐻 ∗ 𝑘/𝐷𝑒∗(��/𝑘 )^(1/2)∗∅_�


�^′ �=𝜋∗(𝑂𝐷^2)/4

��=𝑁� ∗(�^′ �)/144𝑛

𝐺�=𝑤/��

𝑅𝑒=𝐷∗𝐺�/�

(�� 〖 /𝑘) 〗 ^(1/2)

ℎ𝑖=𝐽_𝐻∗𝑘/𝐷∗(��/𝑘 )^(1/2) ∗ ∅�

ℎ𝑖𝑜/(∅𝑖)=ℎ𝑖/(∅𝑖) ∗𝐼𝐷/𝑂𝐷
ℎ𝑖𝑜/(∅𝑖)=ℎ𝑖/(∅𝑖) ∗𝐼𝐷/𝑂𝐷

∆𝑃�= (� 〖𝐺�〗 ^2 𝐷�(𝑁+1))/(5.22 ∗ 〖 10 〗 ^10 𝐷𝑒� ∅�)

∆𝑃�=(� 〖𝐺�〗 ^2 𝐿𝑛)/(5.22 ∗10^10∗𝐷�∅𝑖)

𝑉^2/2𝑔′

∆ Pr 〖 =(4𝑛𝑉^2)/(� 2𝑔′) 〗
𝑈�=(ℎ𝑖𝑜 ∗ℎ𝑜)/((ℎ𝑖𝑜+ℎ𝑜))

𝑅�=(𝑈�−𝑈�)/(𝑈�∗𝑈�)
PREHEATER (E-101)
Fungsi : Memanaskan NaOH sebelum masuk ke reaktor Sodium Silikat
INPUT
Aliran Massa X Rho Rho.X Cp (J/g K) Cp.X (J/gK)
NaOH 3690.17 0.08 w/mk ### 435.58 34.70
H2O 42632.11 0.92 0.00 0.00 377.49 347.41
Total 46322.28 1 ### 382.11

OUTPUT
Aliran Massa X Rho Rho. X Cp (J/g K) Cp . X
NaOH 3690.17 0.08 btuh/ftf ### 11905.91 948.46
H2O 42632.11 0.92 0.00 0.00 10409.19 9579.96
Air 0.00 1 ### 10528.42

Fluida Dingin
Massa = 46,322.28 kg/jam = 102123.7 lb/jam
T in = 30 C = 86 F
T out = 162 C = 323.6 F
Tave = 204.8 F
Tchange = 237.6 F
Cp = 382.11 J/gK
= 91.33 btu/lb F
k = 0 btu/hr ft F
Fluida Panas (udara dari rotary kiln)
Massa = 302,971.67 kg/jam = 667941.6825121 lb/jam
T in = 800 C = 1472 F
T out = 736.12 C = 1357.0123364978 F
Tave = 1414.50617 F
Tchange = 114.987664 F
Cp = 28136.60 J/gK
= 6721.83 btu/lb F
k = 0.00 btu/hr ft F
Jenis heat exchanger = Floating head 1-2 heat exchanger
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 7344040.64048032 Kj/jam
= 2040011.28902231 j/s
= 6960832.8693565 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t3 = Temperatur fluida dingin iunlet
t4 = Temperatur fluida dingin ounlet

(752oF- 644oF) - (716oF - 364oF)


∆TLMTD =
ln [(752oF- 644oF) / (716oF - 364oF)]

= #REF! o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur

Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada


grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two-four tube pass/ 1 shell pass 2 tube pass
(T1-T2)
R =
(t2-t1)
( 752oF- 716oF)
=
(644oF - 364oF)
= #REF!

Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008). Ft = 0,95. Sehingga nilai ∆T M adalah

∆TM = 0,95 x 615,3oC


= #REF! o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = Light Organic
Hot Fluid = Steam
Range nilai U = 100 - 200 Btu/jam.ft2.F (kern. 840)
(diambil nilai 150Btu/jam.ft2.F sebagai tebakan awal)
Ud = 150 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 6960832.8693565 Btu/h
(150 Btu/ft2.oF.h)(196,2oF)
= #REF! ft2
= #REF! m3

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 16 BWG
Outside Diameter (OD) = 0.75 in 0.062499365 ft
Inside Diameter (ID) = 0.62 in 0.0516661417 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 6 ft
Flow area per tube (at') = 0.302 in2 0.00302 ft
luas permukaan luar (a'' = 0.1963 ft/ft2

Number of tube (Nt)


Area
=
L x a''
#REF! ft2
=
16 ft x 0,196 ft/ft2
= #REF!

Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 19 1/4 in dengan
jumlah tube sebesar 220, pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''
= 220 x 6 ft x 0,196 ft
= 259.116 ft2

Q
Ud =
A x ∆TM
6960832.87 Btu/h
=
(259,1 ft2) x 196,2 oF
= #REF! Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)
Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
144.n
220 x 0,302
=
144 x 2
= 0.2306944444 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
#REF! lbm/h
=
0.2306944444 ft2
= #REF! lbm/h.ft2
3. Menentukan bilangan reynold (NRe)
NRe = Gt x ID
μ
= #REF! lbm/h.ft2 x 0.0516661417 ft
#REF! lbm/ft.h
= #REF!

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 75

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = #REF! Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)


= #REF!

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 19.25 in = 1.6041503683 ft
B = Baffle Spacing (0,2 ID) 3.85 in 0.3208300737 ft
PT = Tube Pitch 1 In 0.0833324867 ft
C = Clearench (PT-OD) 1 In 0.0833324867 ft

Area of shell 1,604 x 0,083 x 0,32


=
(as) 144 x 0,083
= 0.51467 ft2

2. Shell side Velocity


Shell side Velocity Mass flow
=
(Gs) area shell
0 lbm/h
=
0.5146701389 ft2
= 0 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
0 lbm/h.ft2 1.6041503683 ft
=
0 lbm/ft.h
= #DIV/0!

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 10423.5

5. Menentukan nilai (hi)


Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = #DIV/0! Btu/jam.oF

Menentukan Nilai Uc

Uc = #DIV/0! Btu/jam.oF

Menentukan Nilai Rd

= #DIV/0!

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. #DIV/0! > 0.003

maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = #REF!
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.0625 ft
jumlah tube pass (n) = 2
Tube side velocity (Gt) = #REF! lbm/h
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00018

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ
0,00018 x (157978,95 lbm/h)2 x 6 ft x 2
=
5,22.1010 x 0,0625 ft x 1
= #REF! psia

2. menghitung ∆P karena tube pass

∆Pr 4n V2
= x
s 2g
Dimana,
s = spesific volume diukur pada T mean
= 0.9 (Figur 6, kern)
Dari figur 27 buku kern hal 837 , diperoleh V2
= 0.085
2g
∆P = 4x2 x 0.085
0.9

= 0.7555555556 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.75555556 Psi + #REF! Psi
= #REF! Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
−𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))
𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))
𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))
4 𝑃𝑇
𝑇_�2))/((𝑇_ℎ2−𝑇_(�1)) ))
4 𝑃𝑇
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 134

1. Heater (HE-101)

Deskripsi
Fungsi : Memanaskan umpan reaktor dengan mengintegrasi panas keluaran
reaktor sebagai pemanas
Jenis : Shell and tube heat exchanger
Bahan : Carbon Steel SA-226 Grade C

Data Propertis fluida


Fluida Panas (tube)
Masuk
Komponen BM F9 (Kg/jam) yi BMC
F9 (Kmol/jam)
C18H30O2 278.42 21.71 0.0779829462 0.000 0.0113
C18H32O2 280.45 45.44 0.1620143926 0.000 0.0236
C18H34O2 282.46 81.97 0.290197252 0.000 0.0425
C18H36O2 284.48 71.07 0.2498191941 0.000 0.0369
C16H32O2 256.42 53.41 0.2082974619 0.000 0.0277
C14H28O2 228.37 3.74 0.0163644474 0.000 0.0019
C12H24O2 200.32 3.03 0.0151088727 0.000 0.0016
H2 2.016 3512.11 1742.09899763 0.904 1.8218
C18H38 254.49 6357.76 24.9819194508 0.013 3.2978
C17H36 240.47 1441.76 5.9956606779 0.003 0.7479
C16H34 226.44 4716.71 20.8297463363 0.011 2.4466
C15H32 212.41 1061.89 4.9991391593 0.003 0.5508
nC14H30 198.39 324.66 1.6364447884 0.001 0.1684
nC13H28 184.36 72.41 0.3927467619 0.000 0.0376
nC12H26 170.33 257.36 1.5108875792 0.001 0.1335
nC11H24 156.31 56.68 0.3626131025 0.000 0.0294
CO2 44.01 86.19 1.9583794049 0.001 0.0447
CO 28.01 274.27 9.791897439 0.005 0.1423
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 135

H2O 18.015 2022.66 112.275651464 0.058 1.0492


Total 20464.81 1927.854 1 10.615
Laju alir massa (kg/h) = 45117.41 lbm/h
Tekanan = 39.5 atm
Temperatur Input = 340 o
C = 644 o
F
Temperatur Onput = 270 o
C = 518 o
F
Tc (Temperatur Mean) = T1 +T2
2
= 305 o
C
= 581 o
F
= 578.15 o
K

Data propertis
a. viskositas campuran pada T mean

μ
Komponen A B C D yi μ.yi
cp
C18H30O2 0.000
C18H32O2 -2.5389 1265.7 0.000 -5E-07 0.21806 0.000 0.000
C18H34O2 -6.1303 1689.3 0.008 -6E-06 0.29985 0.000 0.000
C18H36O2 -3.5929 1346.5 0.003 -3E-06 0.31305 0.000 0.000
C16H32O2 -9.4484 2098.3 0.017 -1E-05 0.37174 0.000 0.000
C14H28O2 -6.731 1266.6 0.012 -1E-05 0.11888 0.000 0.000
C12H24O2 -8.6022 1871.3 0.015 -1E-05 0.24416 0.000 0.000
H2 27.758 0.212 0.000 - 0.00014 0.904 0.000
C18H38 -8.5505 1670.8 0.01568 -1E-05 0.18916 0.013 0.002
C17H36 -8.1307 1579.1 0.01495 -1E-05 0.17243 0.003 0.001
C16H34 -8.1894 1557.1 0.01527 -1E-05 0.15743 0.011 0.002
C15H32 -7.8643 1479.8 0.01472 -1E-05 0.13965 0.003 0.000
nC14H30 -7.8717 1446.7 0.01494 -1E-05 0.12348 0.001 0.000
nC13H28 -7.2994 1324.8 0.01397 -1E-05 0.10656 0.000 0.000
nC12H26 -7.0687 1253 0.01374 -1E-05 0.09047 0.001 0.000
nC11H24 -6.7868 1168.2 0.01344 -1E-05 0.0759 0.000 0.000
CO2 11.336 0.499 0.000 - 0.00026 0.001 0.000
CO 35.086 0.507 0.000 - 0.00028 0.005 0.000
H2O -36.826 0.429 -2E-05 - 0.00021 0.058 0.000
Total 0.005
μ campuran = 0.005 cp
= 0.0132166 lbm/ft.h
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 136

b. konduktivitas termal

k
Komponen A B C yi k.yi
w/m.K
C18H30O2 0.000
C18H32O2 -1.7073 0.9823 775 0.09052 0.000 0.000
C18H34O2 -2.9905 2.6266 781 0.06258 0.000 0.118
C18H36O2 -1.8215 1.1522 799 0.09472 0.000 0.104
C16H32O2 -1.6139 0.9634 776 0.10916 0.000 0.000
C14H28O2 -1.3018 0.6091 756 0.12619 0.000 0.000
C12H24O2 -1.4322 0.7077 734 0.10528 0.000 0.000
H2 0.03951 0.000 0.000 0.040 0.904 0.036
C18H38 -1.5198 0.8067 745.26 0.1015 0.013 9.657
C17H36 -1.5446 0.8191 733.37 0.09572 0.003 0.000
C16H34 -1.8486 1.1616 720.6 0.07627 0.011 0.001
C15H32 -1.765 1.0668 706.8 0.07774 0.003 0.000
nC14H30 -1.6813 0.9584 692.4 0.07789 0.001 0.000
nC13H28 -1.6564 0.9372 675.8 0.07636 0.000 0.000
nC12H26 -1.7989 1.1109 658.2 0.0645 0.001 0.000
nC11H24 -1.6318 0.9325 638.76 0.06982 0.000 0.000
CO2 -0.0118 0.000 0.000 -0.012 0.001 0.000
CO 0.0015 0.000 0.000 0.002 0.005 0.000
H2O -0.2758 0.00461 -6E-06 4.22281 0.058 0.246
Total 10.1616042
konduktivitas termal (k) = 10.161604 J/m.soK
= 5.8712822 W/m2.oF

c. Kapasitas panas
Nilai Cp pada berbagai rentang temperatur dapat digunakan pedekatan
dengan rumus
Cp = A + BT + CT2 + DT3+ ET4
Dimana ,
Cp = Kapasitas Panas (Kj/Kmol.K)
A,B,C, dan E = Koefisien regresi untuk senyawa kimia
T = Temperatur (K)
(Sumber : Yaws,1996)
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 137

Komponen A B C D E Cp yi Cp.yi

C18H30O2 0.000
C18H32O2 241.348 2.3065 -0.0051 5E-06 798.726 0.000 0.06712
C18H34O2 278.686 2.5434 -0.0054 5E-06 883.864 0.000 0.13305
C18H36O2 99.012 3.5874 -0.0072 6E-06 891.093 0.000 0.11547
C16H32O2 86 3.5237 -0.0073 6E-06 855.035 0.000 0.09238
C14H28O2 80.266 2.8162 -0.006 5E-06 690.923 0.000 0.00586
C12H24O2 50.801 2.258 -0.005 4E-06 542.22 0.000 0.00425
H2 25.399 0.02018 -4E-05 3E-08 -9E-12 29.3619 0.904 26.5328
C18H38 151.154 2.7878 -0.0062 6E-06 773.526 0.013 10.0237
C17H36 113.571 2.8548 -0.0064 6E-06 761.648 0.003 2.36874
C16H34 89.101 2.7062 -0.0061 6E-06 710.322 0.011 7.67477
C15H32 94.014 2.4973 -0.0058 6E-06 671.886 0.003 1.74227
nC14H30 111.814 2.2092 -0.0053 5E-06 615.344 0.001 0.52233
nC13H28 85.027 2.2008 -0.0054 5E-06 607.09 0.000 0.12368
nC12H26 84.485 2.0358 -0.0051 5E-06 565.904 0.001 0.44351
nC11H24 94.169 1.7806 -0.0046 5E-06 535.885 0.000 0.1008
CO2 27.437 0.04232 -2E-05 4E-09 -3E-13 46.104 0.001 0.04683
CO 29.556 -0.0066 2E-05 -1E-08 2E-12 30.3698 0.005 0.15425
H2O 92.053 -0.04 -0.0002 5E-07 101.745 0.058 5.9255
Total 56.0773
cp campuran = 56.077261 kJ/kmol.K
= 13.393824 Btu/lbm.oF

d. Data Densitas
Fraksi minyak dan gas dalam campuran
fraksi gas = 0.910
fraksi minyak = 0.090

1. Densitas Minyak
Fraksi Minyak
Masuk
Komponen yi
F6 (Kmol/jam)
C18H30O2 0.0779829462 0.00126331
C18H32O2 0.1620143926 0.00262461
C18H34O2 0.290197252 0.00470115
C18H36O2 0.2498191941 0.00404704
C16H32O2 0.2082974619 0.00337439
C14H28O2 0.0163644474 0.0002651
C12H24O2 0.0151088727 0.00024476
C18H38 24.9819194508 0.40470351
C17H36 5.9956606779 0.09712884
C16H34 20.8297463363 0.3374389
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 138

C15H32 4.9991391593 0.08098534


nC14H30 1.6364447884 0.02651017
nC13H28 0.3927467619 0.00636244
nC12H26 1.5108875792 0.02447616
nC11H24 0.3626131025 0.00587428
61.7289424232 1

Prediksi densitas minyak menggunakan rumus dibawah ini :

(Sumber : Yaws, 1959)


Prediksi densitas Asam Linolenic menggunakan grafik dibawah ini :

(Sumber : Cruz,2010)

ρ ρ.yi
Komponen A B n Tc RMS
(Kg/m3) (Kg/m3)
C18H30O2 857 1.08266
C18H32O2 0.2583 0.23756 0.2886 775 0.67334 679.895 1.78446
C18H34O2 0.28245 0.26812 0.2897 781 0.67669 688.309 3.23585
C18H36O2 0.2798 0.26862 0.3025 799 0.67775 681.944 2.75985
C16H32O2 0.27973 0.26805 0.2947 776 0.66848 674.474 2.27594
C14H28O2 0.28169 0.26965 0.2836 756 0.66339 672 0.17815
C12H24O2 0.28418 0.2655 0.2933 734 0.63476 659.442 0.16141
C18H38 0.23837 0.25763 0.274 745.26 0.66388 586.516 237.365
C17H36 0.23953 0.25316 0.3052 733.37 0.62256 563.354 54.718
C16H34 0.24348 0.25442 0.3238 720.6 0.59161 547.198 184.646
C15H32 0.24137 0.25375 0.31579 706.8 0.58392 537.602 43.5379
nC14H30 0.23556 0.25588 0.27348 692.4 0.61094 541.699 14.3605
nC13H28 0.23767 0.2504 0.312 675.8 0.54686 506.799 3.22448
nC12H26 0.23405 0.25183 0.2896 658.2 0.54327 495.074 12.1175
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 139

nC11H24 0.23143 0.24999 0.28571 638.76 0.51024 469.489 2.75791


Total 564.206
Densitas (ρ) = 564.21 kg/m3
= 35.149 lb/ft3

Densitas Vapour

Komponen mol yi BM BM gas

H2 1478.71292 0.92111 2.01602 1.85698


CO2 0.27888297 0.00017 44.0095 0.00765
CO 3.98404241 0.00248 28.0101 0.06951
H2O 122.379018 0.07623 18.0151 1.37332
1605.35486 3.30746

ρ vapour = P x BM
RxT
Dimana,
P = Tekanan absolut N/m2 (Pa)
V = Volume, m3
N = Mol Gas
T = Temperatur absolut , K
R = Konstanta gas universal, Kj/kmol.K
= 8314 Kj/kmol.K

Densitas Vapour = 4000000 Pa x 3,3075 kg/kmol


8,314 Kj/kmol.K x (330 +273,15) K
= 2.752355 kg/m3
= 0.1714646 lb/ft3

Densitas campuran = (Densitas Vapour.yi) + (Densitas Liquid.yi)


= 0.1559885 lb/ft3 + 3.1724432 lb/ft3
= 3.3284317 lb/ft3

Fluida Dingin (Shell)


Masuk
Komponen BM F6 (Kg/jam) yi BMC
F6 (Kmol/jam)
C18H30O2 278.42 2171.24 7.80 0.12 32.75
C18H32O2 280.45 2378.49 8.48 0.13 35.88
C18H34O2 282.46 3666.43 12.98 0.20 55.31
C18H36O2 284.48 710.59 2.50 0.04 10.72
C16H32O2 256.42 6676.56 26.04 0.39 100.71
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 140

C14H28O2 228.37 467.15 2.05 0.03 7.05


C12H24O2 200.32 378.32 1.89 0.03 5.71
H2 2.016 0.00 0.00 0.00 0.00
C18H38 254.49 0.00 0.00 0.00 0.00
C17H36 240.47 0.00 0.00 0.00 0.00
C16H34 226.44 0.00 0.00 0.00 0.00
C15H32 212.41 0.00 0.00 0.00 0.00
nC14H30 198.39 0.00 0.00 0.00 0.00
nC13H28 184.36 0.00 0.00 0.00 0.00
nC12H26 170.33 0.00 0.00 0.00 0.00
nC11H24 156.31 0.00 0.00 0.00 0.00
CO2 44.01 0.00 0.00 0.00 0.00
CO 28.01 0.00 0.00 0.00 0.00
H2O 18.015 82.24 4.57 0.07 1.24
Total 16531.03 66.29 1.00 249.36
Laju alir massa (kg/h) = 36444.867 lbm/h
Tekanan = 39.5 atm
Temperatur Input = 30 o
C = 86 o
F
Temperatur Onput = 193.07 o
C = 379.52246 F
o

Tc (Temperatur Mean) = T1 +T2


2
= 111.53402 oC
= 232.76123 oF
= 384.68402 oK

Data propertis
a. viskositas campuran pada T mean

μ
Komponen A B C D yi μ.yi
cp
C18H30O2
C18H32O2 -2.5389 1265.7 0.000 -5E-07 3.79351 0.128 0.485
C18H34O2 -6.1303 1689.3 0.008 -6E-06 3.37197 0.196 0.000
C18H36O2 -3.5929 1346.5 0.003 -3E-06 4.1522 0.038 0.000
C16H32O2 -9.4484 2098.3 0.017 -1E-05 3.35876 0.393 1.319
C14H28O2 -6.731 1266.6 0.012 -1E-05 0.57122 0.031 0.018
C12H24O2 -8.6022 1871.3 0.015 -1E-05 2.09512 0.028 0.060
H2 0.03951 0.000 0.000 - 2E-07 0.000 0.000
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 141

C18H38 -8.5505 1670.8 0.01568 -1E-05 0.99194 0.000 0.000


C17H36 -8.1307 1579.1 0.01495 -1E-05 0.89333 0.000 0.000
C16H34 -8.1894 1557.1 0.01527 -1E-05 0.79759 0.000 0.000
C15H32 -7.8643 1479.8 0.01472 -1E-05 0.70365 0.000 0.000
nC14H30 -7.8717 1446.7 0.01494 -1E-05 0.61263 0.000 0.000
nC13H28 -7.2994 1324.8 0.01397 -1E-05 0.53691 0.000 0.000
nC12H26 -7.0687 1253 0.01374 -1E-05 0.46191 0.000 0.000
nC11H24 -6.7868 1168.2 0.01344 -1E-05 0.39278 0.000 0.000
CO2 -0.0118 0.0001 -2E-08 - 2E-08 0.000 0.000
CO 0.0015 8E-05 -2E-08 - 3E-08 0.000 0.000
H2O -36.826 0.429 -2E-05 - 0.00013 0.069 0.000
Total 1.882
μ campuran = 1.882 cp
= 4.5522333 lbm/ft.h

b. konduktivitas termal

k
Komponen A B C yi k.yi
w/m.K
C18H30O2
C18H32O2 -1.7073 0.9823 775 0.12595 0.128 0.016
C18H34O2 -2.9905 2.6266 781 0.14904 0.196 152.919
C18H36O2 -1.8215 1.1522 799 0.13601 0.038 30.105
C16H32O2 -1.6139 0.9634 776 0.15078 0.393 0.059
C14H28O2 -1.3018 0.6091 756 0.15679 0.031 0.005
C12H24O2 -1.4322 0.7077 734 0.13811 0.028 0.004
H2 0.03951 0.000 0.000 0.207 0.000 0.000
C18H38 -1.5198 0.8067 745.26 0.1367 0.000 0.000
C17H36 -1.5446 0.8191 733.37 0.13114 0.000 0.000
C16H34 -1.8486 1.1616 720.6 0.12173 0.000 0.000
C15H32 -1.765 1.0668 706.8 0.12225 0.000 0.000
nC14H30 -1.6813 0.9584 692.4 0.11992 0.000 0.000
nC13H28 -1.6564 0.9372 675.8 0.12033 0.000 0.000
nC12H26 -1.7989 1.1109 658.2 0.11628 0.000 0.000
nC11H24 -1.6318 0.9325 638.76 0.12155 0.000 0.000
CO2 -0.0118 0.000 0.000 0.024 0.000 0.000
CO 0.0015 0.000 0.000 0.030 0.000 0.000
H2O -0.2758 0.00461 -6E-06 0.679 0.069 0.047
Total 183.154548
konduktivitas termal (k) = 183.15455 J/m.soK
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 142

= 105.82503 W/m2.oF

c. Kapasitas panas
Nilai Cp pada berbagai rentang temperatur dapat digunakan pedekatan
dengan rumus
Cp = A + BT + CT2 + DT3+ ET4
Dimana ,
Cp = Kapasitas Panas (Kj/Kmol.K)
A,B,C, dan E = Koefisien regresi untuk senyawa kimia
T = Temperatur (K)
(Sumber : Yaws,1996)

Komponen A B C D E Cp yi Cp.yi

C18H30O2
C18H32O2 241.348 2.3065 -0.0051 5E-06 649.119 0.128 83.0428
C18H34O2 278.686 2.5434 -0.0054 5E-06 733.041 0.196 143.528
C18H36O2 99.012 3.5874 -0.0072 6E-06 742.46 0.038 27.9748
C16H32O2 86 3.5237 -0.0073 6E-06 705.578 0.393 277.117
C14H28O2 80.266 2.8162 -0.006 5E-06 566.268 0.031 17.4726
C12H24O2 50.801 2.258 -0.005 4E-06 433.712 0.028 12.3557
H2 25.399 0.02018 -4E-05 3E-08 -9E-12 29.0796 0.000 0
C18H38 151.154 2.7878 -0.0062 6E-06 627.378 0.000 0
C17H36 113.571 2.8548 -0.0064 6E-06 599.757 0.000 0
C16H34 89.101 2.7062 -0.0061 6E-06 547.81 0.000 0
C15H32 94.014 2.4973 -0.0058 6E-06 512.269 0.000 0
nC14H30 111.814 2.2092 -0.0053 5E-06 473.495 0.000 0
nC13H28 85.027 2.2008 -0.0054 5E-06 444.81 0.000 0
nC12H26 84.485 2.0358 -0.0051 5E-06 410.274 0.000 0
nC11H24 94.169 1.7806 -0.0046 5E-06 376.718 0.000 0
CO2 27.437 0.04232 -2E-05 4E-09 -3E-13 41.0421 0.000 0
CO 29.556 -0.0066 2E-05 -1E-08 2E-12 29.3569 0.000 0
H2O 33.933 -0.0084 3E-05 -2E-08 -4E-12 34.0245 0.069 2.34306
Total 563.835
cp campuran = 563.83463 kJ/kmol.K
= 134.66959 Btu/lbm.oF

d. Data Densitas
Fraksi minyak dan gas dalam campuran
fraksi gas = 0.890
fraksi minyak = 0.110
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 143

1. Densitas Minyak

Prediksi densitas minyak menggunakan rumus dibawah ini :

(Sumber : Yaws, 1959)


Prediksi densitas Asam Linolenic menggunakan grafik dibawah ini :

(Sumber : Cruz,2010)

ρ ρ.yi
Komponen A B n Tc RMS
(Kg/m ) (Kg/m3)
3

C18H30O2 857 100.81


C18H32O2 0.2583 0.23756 0.2886 775 0.82041 839.935 107.454
C18H34O2 0.28245 0.26812 0.2897 781 0.82158 832.946 163.089
C18H36O2 0.2798 0.26862 0.3025 799 0.81983 821.97 30.9706
C16H32O2 0.27973 0.26805 0.2947 776 0.81729 820.45 322.233
C14H28O2 0.28169 0.26965 0.2836 756 0.81739 822.301 25.3727
C12H24O2 0.28418 0.2655 0.2933 734 0.8043 825.691 23.5225
C18H38 0.23837 0.25763 0.274 745.26 0.81961 724.439 0
C17H36 0.23953 0.25316 0.3052 733.37 0.79699 715.896 0
C16H34 0.24348 0.25442 0.3238 720.6 0.78104 709.17 0
C15H32 0.24137 0.25375 0.31579 706.8 0.78024 703.699 0
nC14H30 0.23556 0.25588 0.27348 692.4 0.80108 701.964 0
nC13H28 0.23767 0.2504 0.312 675.8 0.76893 689.257 0
nC12H26 0.23405 0.25183 0.2896 658.2 0.77545 681.899 0
nC11H24 0.23143 0.24999 0.28571 638.76 0.76844 671.551 0
Total 773.453
Densitas (ρ) = 773.45 kg/m3
= 48.184 lb/ft3
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 144

Panas yang terserap


Q cold = Q hot = Q
Q yang dibutuhkan = 7053698.68 Kj/jam
= 1959360.74569 j/s
= 6685640.78782 Btu/h

Menentukan ∆TLMTD Dan ∆TM


Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t3 = Temperatur fluida dingin iunlet
t4 = Temperatur fluida dingin ounlet

(644oF - 377oF) - (518oF - 86oF)


∆TLMTD =
ln [(644oF - 377oF) / (518oF - 86oF)]
= 341.42 oF

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur

Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada


grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell pass-two tube pass/ 1 shell pass 2 tube pass

(T1-T2) (t2-t1)
R = S =
(t2-t1) (T1-t1)
(644oF- 518oF) (377oF - 86oF)
= =
(377oF - 86oF) ( 644oF- 86oF)
= 0.43 = 0.5260259

Syarat design Heat exchanger yang ekonomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar). Ft = 0,98. Sehingga nilai ∆TM adalah (hal 828 Kern, 1965)

∆TM = 0,98 x 393,6oC


= 334.59 oF
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 145

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk tipe Heat exchanger dengan jenis
fluida:
Cold Fluid = Light organik
Hot Fluid = Light organik
Range nilai U = 40 - 75 Btu/jam.ft2.F (kern. 840)
(diambil nilai 50 Btu/jam.ft2.F sebagai tebakan awal)

Ud = 50 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

Q
A =
Ud x ∆TM
6685640.7878 Btu/h
=
(50 Btu/ft2.oF.h)(342oF)
= 399.63 ft2
= 37.141 m3

Karena luas area heat transfer >200 ft 2, maka jenis HE yang digunakan adalah
shell and Tube. (Kern,1965)

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern,1965) , yaitu
sebagai berikut :
- Dipilih jenis tube 16 BWG
- Outside Diameter (ODt) = 0.75 in = 0.0625 ft
- Inside Diameter (IDt) = 0.62 in = 0.0517 ft
- Range Lenght of Tube (6 ft - 24 ft, Towler 2008)
Lenght of tube = 6 ft = 1.8288 m
- Flow area per tube (at') = 0.302 in2 = 0.003 ft
- luas permukaan luar (a'') = 0.1963 ft/ft2

Number of tube (Nt) Area


=
L x a''
399.634 ft2
=
6 ft x 0,196 ft/ft2
= 339.31

Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 146

square pitch. nilai jumlah tube terdekat didapati pada ID Shell 25 in dengan
jumlah tube sebesar 394, pada jarak antar tube (PT) = 1 in dan 2 tube pass
sehingga dapat disimpulkan : - Jumlah Tube = 394
- ID shell (IDS) = 25 in
- Jarak antar Tube = 1 in 2 tube pass

A = Nt x L x a''
= 394 x 6 ft x 0,196 ft
= 464.05 ft2
= 43.128 m3

Q
Ud =
A x ∆TM
6685640.7878 Btu/h
=
(43,13 ft2) x 335,5 oF
= 43.059 Btu/jam.ft2.F (masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube Nt . at'
=
(at) n (Eq 7.48 Kern,1965)
394 x 0,302
=
2
= 59.494 in2 59.494
= 0.4132 ft2

2. Tube side Velocity


Tube side Velocity Mass flow
=
(Gt) area per pass
45117.41 lbm/h
=
0.4131528 ft2
= 109202.73 lbm/h
3. Menentukan bilangan reynold (NRe)
Gt x ID
NRe =
μ
109202.73 lbm/h x 0.0517 ft
=
0.013217 lbm/ft.h
= 426895.06

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 90
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 147

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
karena viskositas sangat rendah maka nilai φs = 1
hi = 3183.2159 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)

= 2631.4585

a. Shell
1. Luas Area shell

Dimana,
Ds = Diamter dalam shell = 25 in = 2.0833122 ft
B= Baffle Spacing (0,2 ID) = 5 in = 0.4166624 ft
PT = Tube Pitch = 1 In = 0.0833325 ft
C= Clearench (PT-OD) = 0.38 In = 0.0316663 ft

Area of shell 29 in x 0,25 in x 5,8 in


=
(as) 1 in
= 47.5 in2
= 0.3298611 ft2
2. Shell side Velocity
Shell side Velocity Mass flow
=
(Gs) area shell
36444.867 lbm/h
=
0.3298611 ft2
= 110485.49 lbm/h

3. Menentukan bilangan reynold (NRe)


Gs x De
NRe =
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 148

NRe =
μ
110485.49 lbm/h x 2.0833 ft
=
4.552233 lbm/ft.h
= 50563.2633632

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 230

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
karena viskositas sangat rendah maka nilai φs = 1
hi = 20982.815 Btu/jam.oF

Menentukan Nilai Uc

Uc = 2338.2217 Btu/jam.oF

Menentukan Nilai Rd

= 0.0227962
Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,01
Rd > Rd min.
0.0227962 > 0.01 0.0112
maka spesifikasi heater dapat diterima
Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 426895.06
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.0516661 ft
jumlah tube pass (n) = 2
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 149

Tube side velocity (Gt) = 109202.73 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00016

1. menghitung ∆P karena panjang pipa


f x Gt2 x L x n
∆Ps
= 5,22.1010 x IDt x φ
0,00016 x (5496 lbm/h)2 x 6 ft x 2
=
5,22.1010 x 0,0516 ft x 1
= 0.0084897 psia

2. menghitung ∆P karena tube pass

4n V2
∆Pr = x
s 2g
Dimana,
s = spesific volume diukur pada T mean (Figur 6, kern)
= 0.84

V2
Dari figur 27 buku kern hal 837 , diperoleh = 0.015
2g
4x2
∆Pr = x 0.015
0.84
= 0.1428571 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.0084897 Psi + 0.1429 Psi
= 0.1513468 Psi

∆PT yang diizinkan < 10 psi, maka syarat terpenuhi

b. Shell side
Diketahui ,
Bilangan Reynold Nre = 50563.263
Panjang Shell (L) = 6 ft
Diameter dalam (IDS) = 25 in = 2.0833122 ft
Jumlah shell pass (n) = 1
Shell side velocity (Gs) = 110485.49 lbm/h

f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x Dt x s x φ (Eq. 7.44 Kern, 1965)
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 150

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.003
s = spesific volume diukur pada T mean
= 0.987
Banyaknya crosses,
12 L
N+1 =
B
12 x 6 ft
=
0,48 ft
= 172.80176
Maka pressur drop pada shell adalah ,
f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x Dt x s x φ
0,003 x (99244,03 lbm/h)2 x 2,4 ft x 172
∆Ps =
5,22.1010 x 0,057 ft x 0,98 x 1
= 4.9526835 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (HE-101)
Nama Heat Exchanger
Kode HE-101
Fungsi Memanaskan umpan reaktor dengan
mengintegrasi panas keluaran reaktor
sebagai pemanas
Tipe Shell and Tube
Bahan Commercial Steel
Jumlah 1 Buah
Area Heat Transfer (A) 43.13 m3
Coefisien Overall (Ud) 43.06 Btu/jam.oF
Clean Overall Coefisien 2338.22 Btu/jam.oF
Dirt Factor (Rd) 0.02
Dimensi
Diameter Shell 0.64 m
Diameter Tube 0.02 m
Jumlah Tube 394 m
Panjang (L) 1.83 m
Delta P (Shell) 0.15 Psi
Delta P (Tube) 4.95 Psi
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 151

GUDANG
Densitas Vapour

Komponen mol yi BM BM gas

H2 1478.71292 0.92111 2.01602 1.85698


CO2 0.27888297 0.00017 44.0095 0.00765
CO 3.98404241 0.00248 28.0101 0.06951
H2O 122.379018 0.07623 18.0151 1.37332
1605.35486 3.30746

ρ vapour = P x BM
RxT
Dimana,
P = Tekanan absolut N/m2 (Pa)
V = Volume, m3
N = Mol Gas
T = Temperatur absolut , K
R = Konstanta gas universal, Kj/kmol.K
= 8314 Kj/kmol.K

Densitas Vapour = 4000000 Pa x 3,3075 kg/kmol


8,314 Kj/kmol.K x (85,73 +273,15) K
Lampiran C
Perancangan Alat Proses
(HE-101) salah - 152

= 14.267163 kg/m3
= 0.8888072 lb/ft3

Densitas campuran = (Densitas Vapour.yi) + (Densitas Liquid.yi)


= 0.7906499 lb/ft3 + 5.3213151 lb/ft3
= 6.1119649 lb/ft3
HEATER (E-101)
Fungsi : Memanaskan NaOH sebelum masuk ke reaktor Sodium Silikat
INPUT
Aliran Massa X densitas campuran Cp (J/g K) Cp.X (J/gK)
NaOH 3690.17 0.08 435.58 34.70
H2O 42632.11 0.92 985.00 377.49 347.41
Total 46322.28 1 382.11

Fluida Dingin (NaOH)


Massa = 46,322.28 kg/jam = 102123.7 lb/jam
T in = 30 C = 86 F
T out = 162 C = 323.6 F
Tave = 204.8 F
Tchange = 237.6 F
Cp = 382.11 J/gK
= 91.33 btu/lb F
k = 0.30743899 btu/hr ft F
densitas = 985.00 kg/m3 61.3629 lb/ft3
viskositas = 2.448 cp 5.92193 lb/ft.h
(viskositas >1 cp, termasuk kedalam heavy organic, Kern 840)
Fluida Panas (STEAM)
Massa = 90,000.00 kg/jam = 198417.073 lb/jam
T in = 350.00 C = 662 F
T out = 211.25 C = 412.250249 F
Tave = 537.125124 F 280.625 C
Tchange = 249.749751 F 553.775 K
Cp = 11346.80 J/gK
= 2710.75 btu/lb F
k = 0.03 btu/hr ft F
densitas = 575.11 kg/m3 = 35.828109 lb/ft3
viskositas = 0.06 cp 0.1419 lbm/ft.h

Panas yang terserap


Q cold = Q hot = Q
Q yang dibutuhkan
= 24,818,035.34 Kj/jam
= 6893898.70577789 j/s
= 23523044.6848121 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

∆TLMTD = 332.2881050115 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two or more tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S= (t2-t1)
(t2-t1) (T1-t1)
= 1.05 = 0.4125

Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008).
Ft = 0.92 sehingga, ∆TM adalah :
∆TM = 305.7050566106 oF

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = steam

Range nilai U = 6 - 60 Btu/jam.ft2.F (kern. 840)


(diambil nilai 60 Btu/jam.ft2.F sebagai tebakan awal)
Ud = 60 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)


A = Q
Ud x ∆TM
= 23523044.684812 Btu/h
(60 Btu/ft2.oF.h)(305,705oF)
= 1282.45 ft2
= 119.143 m2

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 8 BWG
Outside Diameter (OD) = 1 in 0.08333249 ft
Inside Diameter (ID) = 0.67 in 0.05583277 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 15 ft 4.572 m
Flow area per tube (at') = 0.355 in2 0.00355 ft
luas permukaan luar (a'') = 0.2618 ft/ft 2

Number of tube (Nt) = Area = 1282.448 ft2


L x a'' 15 ft x 0,2618 ft/ft2
= 326.572

Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 25 in dengan
jumlah tube sebesar 326 pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''
= 326 x 15 ft x 0,2618 ft
= 1280.2 ft2
Q
Ud =
A x ∆TM
23523044.68 Btu/h
=
(1280,202ft2) x 305,705 oF
= 60.10525027 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
326 x 0,355 (Eq 7.48 Kern,1965)
=
2
= 57.865 in2
= 0.40184 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
102,123.67 lbm/h
=
0.4018402778 ft2
= 254139.96155161 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe = Gt x ID
μ
= 254139.9616 lbm/h.ft2 x 0.05583277 ft
### lbm/ft.h
= 2396.067036
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 28

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 1861.2 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)


= 1247

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 29 in = 2.41664211 ft
B = Baffle Spacing (0,2 ID) 5.8 in 0.48332842 ft
PT = Tube Pitch 1.25 In 0.10416561 ft
C = Clearench (PT-OD) 0.25 In 0.02083312 ft

Area of shell = 29x 0,25 x 5,8


(as) 144 x 1,25
= 33.64 in2
= 0.23361 ft2
2. Shell side Velocity
Shell side Velocity Mass flow
=
(Gs) area shell
198417.07268679 lbm/h
=
0.2336111111 ft2
= 849347.75466401 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
849348 lbm/h.ft2 2.41664211 ft
=
0.1419048673 lbm/ft.h
= 5962.7159221473

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 40

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 10.8502137917 Btu/jam.oF

Menentukan Nilai Uc

Uc = 746.7086397274 Btu/jam.oF
Menentukan Nilai Rd

= 0.0152982712

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.0153 > 0.003
maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 2396.07
Panjang tube (L) = 15 ft
Diameter dalam (ID) = 0.08333 ft
jumlah tube pass (n) = 2
Tube side velocity (Gt) = 254140 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.0014

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
= 0.6236061157 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g
s = 1 (tabel 27 Kern)

Dari figur 27 buku kern hal 837 , diperoleh V2


= 0.008
2g
∆P = 4x2 x 0.008
1

= 0.064 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.064 Psi + 0.62360612 Psi
= 0.687606116 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
b. Shell side
Diketahui ,
Wall thickness = 0.165 in 0.01374986 ft
Bilangan Reynold (Nre) = 5962.72
Panjang Shell (L) = 15 ft
Diameter dalam (De) = 29 in = 2.41664211 ft
Jumlah shell pass (n) = 2
Shell side velocity (Gs) = 849347.75466401 lbm/h
Baffle = 5 in 0.417 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00027

s = 1

Banyaknya crosses,
12 L
N+1 =
B
12 x 15ft
=
0,417 ft
= 431.654676259
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 2.4303919736 ft2

Maka pressur drop pada shell adalah ,


f x Gs2 x Ds x (N+1)
∆Ps =
∆Ps =
5,22.1010 x De x φ x s
∆Ps = 1.6528700279 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (E-101)
Nama Heat Exchanger
Kode E-101
Fungsi Memanaskan NaOH untuk feed reaktor
Tipe Shell and Tube
Jumlah 1 Buah
Diameter Shell 0.74 m
Diameter Tube 0.03 m
Jumlah Tube 326
Panjang Tube 4.57 m
Fouling Factor (Rd) 0.015
Delta P (Shell) 11.39 kPa
Delta P (Tube) 4.74 kPa
HEATER (E-102)
Fungsi : Memanaskan H2SO4 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K) Cp.X (J/gK)
H2SO4 3829.02 0.41 1826.97 752.35 701.57 288.91
H2O 5469.20 0.59 1023.01 601.73 377.49 222.04
Total 9298.23 1 1354.08 510.94

Fluida Dingin (H2So4)


Massa = 9,298.23 kg/jam = 20499.2 lb/jam
T in = 30 C = 86 F
T out = 92.8 C = 199.04 F
Tave = 142.52 F
Tchange = 113.04 F
Cp = 510.94 J/gK
= 122.12 btu/lb F
k = 0.29436176 btu/hr ft F
densitas = 1354.08 kg/m3 84.355923 lb/ft3
viskositas = 8.56 cp 20.717569 lb/ft.h
(viskositas >1 cp, termasuk kedalam heavy organic, Kern 840)
Fluida Panas (STEAM)
Massa = 90,000.00 kg/jam = 198417.07 lb/jam
T in = 211.25 C = 412.25025 F
T out = 205.90 C = 402.62107 F
Tave = 407.435658 F 208.5754 C
Tchange = 9.62918244 F 481.7254 K
Cp = 0.00 J/gK
= 0.00 btu/lb F
k = 0.02 btu/hr ft F
densitas = 830.85 kg/m3 = 51.759602 lb/ft3
viskositas = 0.12 cp 0.2865182 lbm/ft.h

Panas yang terserap


Q cold = Q hot = Q
Q yang dibutuhkan
= 936,806.95 Kj/jam
= 260224.151746929 j/s
= 887924.904449206 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

∆TLMTD = 261.5168865673 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two or more tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S = (t2-t1)
(t2-t1) (T1-t1)

= 0.09 = 0.3464825
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008).
Ft = 1 sehingga, ∆TM adalah :
∆TM = 261.5168865673 oF

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = steam

Range nilai U = 6 - 60 Btu/jam.ft2.F (kern. 840)


(diambil nilai 60 Btu/jam.ft2.F sebagai tebakan awal)
Ud = 60 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)


A = Q
Ud x ∆TM
= 887924.904449206 Btu/h
(60 Btu/ft2.oF.h)(305,705oF)
= 56.58812 ft2
= 5.257206 m2

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 8 BWG
Outside Diameter (OD) = 1 in 0.0833325 ft
Inside Diameter (ID) = 0.67 in 0.0558328 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 6 ft 1.8288 m
Flow area per tube (at') = 0.355 in2 0.00355 ft
luas permukaan luar (a'') = 0.2618 ft/ft2
Number of tube (Nt) = Area = 56.588 ft2
L x a'' 6 ft x 0,1963 ft/ft2
= 36.02503

Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 10 in dengan
jumlah tube sebesar 48 pada jarak antar tube (PT) = 1 in dan 1 tube pass
A = Nt x L x a''

= 75.3984 ft2
Q
Ud =
A x ∆TM
887924.9044 Btu/h
=
(75,3984ft2) x 261,5 oF
= 45.03128811 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
48 x 0,355 (Eq 7.48 Kern,1965)
=
1
= 17.04 in2
= 0.118333 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
20,499.19 lbm/h
=
0.1183333333 ft2
= 173232.604758428 lbm/h.ft2
3. Menentukan bilangan reynold (NRe)
NRe = Gt x ID
μ
= 173232.6048 lbm/h.ft2 x 0.0558328 ft
20.717569 lbm/ft.h
= 466.8528115
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 13

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 1403.928 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)


= 940.6321

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 12 in = 0.9999898 ft
B = Baffle Spacing (0,2 ID) 2.4 in 0.199998 ft
PT = Tube Pitch 1.25 In 0.1041656 ft
C = Clearench (PT-OD) 0.25 In 0.0208331 ft

Area of shell = 10 x 0,25 x 2


(as) 144 x 1
= 7 in2
= 0.05 ft2

2. Shell side Velocity


Shell side Velocity Mass flow
=
(Gs) area shell
198417.072686788 lbm/h
=
0.05 ft2
= 3968341.45373575 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
3968341 lbm/h.ft2 X 0.9999898 ft
=
0.286518233 lbm/ft.h
= 11527.9174494848

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 50

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 0 Btu/jam.oF

Menentukan Nilai Uc

Uc = 563.252733352 Btu/jam.oF
Menentukan Nilai Rd

= 0.0204313801

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.020431 > 0.003
maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 466.85281
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.0833325 ft
jumlah tube pass (n) = 1
Tube side velocity (Gt) = 173232.6 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.0013

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
= 0.0355421057 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g
s = 1 (tabel 27 Kern)

Dari figur 27 buku kern hal 837 , diperoleh V2


= 0.003
2g
∆P = 4x1 x 0.003
1

= 0.024 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.024 Psi + 0.0355421 Psi
= 0.059542106 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
b. Shell side
Diketahui ,
Wall thickness = 0.134 in 0.0111666 ft
Bilangan Reynold (Nre) = 11527.92
Panjang Shell (L) = 6 ft
Diameter dalam (De) = 12 in = 0.9999898 ft
Jumlah shell pass (n) = 1
Shell side velocity (Gs) = 3968341.45373575 lbm/h
Baffle = 2.4 in 0.199998 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00008

s = 1

Banyaknya crosses,
12 L
N+1 =
B
12 x 6ft
=
0,16 ft
= 360.0036576445
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 1.0111563932 ft2

Maka pressur drop pada shell adalah ,


f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
∆Ps = 8.7855146892 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (E-102)
Nama Heat Exchanger
Kode E-102
Fungsi Memanaskan H2SO4 untuk feed reaktor
Tipe Shell and Tube
Jumlah 1 Buah
Diameter Shell 0.31 m
Diameter Tube 0.03 m
Jumlah Tube 48
Panjang Tube 1.83 m
Fouling Factor (Rd) 0.02
Delta P (Shell) 60.57 kPa
Delta P (Tube) 0.41 kPa
Cp.X (J/gK)
HEATER (E-204)
Fungsi : Memanaskan Udara untuk umpan udara panas pada rotary dryer

Fluida Dingin (H2So4)


Massa = 94,054.14 kg/jam = 207355.0 lb/jam
T in = 30 C = 86 F
T out = 92.8 C = 199.04 F
Tave = 142.52 F
Tchange = 113.04 F
Cp = 1.00 J/gK
= 0.24 btu/lb F
k = 0.014 btu/hr ft F
densitas = 1.14 kg/m3 0.07083214 lb/ft3
viskositas = 0.02 cp 0.04160832 lb/ft.h

Fluida Panas (STEAM)


Massa = 17,521.44 kg/jam = 38628.3739 lb/jam
T in = 250.00 C = 482 F
T out = 36.51 C = 97.7138193 F
Tave = 289.85691 F 143.25384 C
Tchange = 384.286181 F 416.40384 K
Cp = 4.98 J/gK
= 1.19 btu/lb F
k = 0.38 btu/hr ft F
densitas = 784.90 kg/m3 = 48.89722926 lb/ft3
viskositas = 0.10 cp 0.252069 lbm/ft.h

Panas yang terserap


Q cold = Q hot = Q
Q yang dibutuhkan
= 7,542,789.40 Kj/jam
= 2095219.27916088 j/s
= 7149211.03886743 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

∆TLMTD = 85.1760376826 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two or more tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S= (t2-t1)
(t2-t1) (T1-t1)

= 3.40 = 0.285454545
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008).
Ft = 0.93 sehingga, ∆TM adalah :
∆TM = 79.2137150449 o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = gases
Hot Fluid = steam

Range nilai U = 5 - 50 Btu/jam.ft2.F (kern. 840)


(diambil nilai 50 Btu/jam.ft2.F sebagai tebakan awal)
Ud = 50 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 7149211.03886743 Btu/h
(50 Btu/ft2.oF.h)(305,705oF)
= 1805.044 ft2
= 167.694 m2

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 8 BWG
Outside Diameter (OD) = 1 in 0.083332487 ft
Inside Diameter (ID) = 0.67 in 0.055832766 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 15 ft 4.572 m
Flow area per tube (at') = 0.355 in2 0.00355 ft
luas permukaan luar (a'') = 0.2618 ft/ft2
Number of tube (Nt) = Area = 1805.044 ft2
L x a'' 20 ft x 0,1963 ft/ft2
= 459.6495

Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 33 in dengan
jumlah tube sebesar 460 pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''

= 1806.42 ft2

Q
Ud =
A x ∆TM
7149211.039 Btu/h
=
(2083,928t2) x 261,5 oF
= 49.96190653 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
460 x 0,355 (Eq 7.48 Kern,1965)
=
2
= 81.65 in2
= 0.567014 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
207,354.97 lbm/h
=
0.5670138889 ft2
= 365696.453307989 lbm/h.ft2
3. Menentukan bilangan reynold (NRe)
NRe = Gt x ID
μ
= 365696.4533 lbm/h.ft2 x 0.055832766 ft
0.041608 lbm/ft.h
= 490715.436
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 400

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 89.63455 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)


= 60.05515

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 31 in = 2.583307087 ft
B = Baffle Spacing (0,2 ID) 6.2 in 0.516661417 ft
PT = Tube Pitch 1.25 In 0.104165608 ft
C = Clearench (PT-OD) 0.25 In 0.020833122 ft

Area of shell = 31x 0,25 x 6,2


(as) 144 x 1
= 38 in2
= 0.266944 ft2

2. Shell side Velocity


Shell side Velocity Mass flow
=
(Gs) area shell

38628.373888037 lbm/h
=
0.2669444444 ft2
= 144705.667010336 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
144705.7 lbm/h.ft2 X 2.583307087 ft
=
0.2520690039 lbm/ft.h
= 1085.9449533196

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 18

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 2.4577341156 Btu/jam.oF
Menentukan Nilai Uc

Uc = 179.2690980426 Btu/jam.oF
Menentukan Nilai Rd

= 0.0144370428

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.014437 > 0.003
maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 490715.436
Panjang tube (L) = 15 ft
Diameter dalam (ID) = 0.08333249 ft
jumlah tube pass (n) = 2
Tube side velocity (Gt) = 365696.453 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.0013

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
= 0.7919456618 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g

s = 1 (tabel 27 Kern)

Dari figur 27 buku kern hal 837 , diperoleh V2


= 0.003
2g
∆P = 4x1 x 0.003
1

= 0.024 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.024 Psi + 0.791945662 Psi
= 0.815945662 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
b. Shell side
Diketahui ,
Wall thickness = 0.134 in 0.011166553 ft
Bilangan Reynold (Nre) = 1085.945
Panjang Shell (L) = 15 ft
Diameter dalam (De) = 31 in = 2.583307087 ft
Jumlah shell pass (n) = 1
Shell side velocity (Gs) = 144705.667010336 lbm/h
Baffle = 6.2 in 0.516661417 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00008

s = 1

Banyaknya crosses,
12 L
N+1 =
B
12 x 6ft
=
0,16 ft
= 348.3906364301
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 2.5944736398 ft2
Maka pressur drop pada shell adalah ,
f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
∆Ps = 0.0112287203 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (E-204)
Nama Heat Exchanger
Kode E-204
Fungsi Memanaskan Udara untuk rotary dryer
Tipe Shell and Tube
Jumlah 1 Buah
Diameter Shell 0.79 m
Diameter Tube 0.03 m
Jumlah Tube 460
Panjang Tube 1.83 m
Fouling Factor (Rd) 0.014
Delta P (Shell) 0.08 kPa
Delta P (Tube) 5.63 kPa
COOLER (E-203)
Fungsi : Mendinginkan Na2O.SiO2 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K) Cp.X (J/gK)
Na2SiO3 10793.14 0.20 2416.00 481.21 86009.26 17130.87
H2O 43396.16 0.80 1023.01 819.25 10409.19 8335.94
Total 54189.30 1 1300.46 25466.81

Fluida Dingin (H2O)


Massa = 555,506.39 kg/jam = 1224688.4 lb/jam
T in = 30 C = 86 F
T out = 35.01 C = 95.01223114 F
Tave = 90.5061156 F
Tchange = 9.01223114 F
Cp = 377.49 J/gK
= 90.22 btu/lb F
k = 0.35424172 btu/hr ft F
densitas = 1023.01 kg/m3 63.7310493 lb/ft3
viskositas = 0.75 cp 1.8207228 lb/ft.h

Fluida Panas (Na2O.SiO2)


Massa = 54,189.30 kg/jam = 119467.588 lb/jam
T in = 162.00 C = 323.6 F
T out = 92.80 C = 199.04 F
Tave = 261.32 F 127.4 C
Tchange = 124.56 F 400.55 K
Cp = 25466.81 J/gK
= 6084.02 btu/lb F
k = 49.00 btu/hr ft F
densitas = 1300.46 kg/m3 = 81.015325867 lb/ft3
viskositas = 0.64 cp 1.53612109 lbm/ft.h
(viskositas 0,5-1 cp, termasuk kedalam medium organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 11,636,853.41 Kj/jam
= 3232459.28109045 j/s
= 11029649.166037 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

∆TLMTD = 164.0887469719 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two or more tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S= (t2-t1)
(t2-t1) (T1-t1)

= 13.82 = 0.0379302658
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008).
Ft = 1 sehingga, ∆TM adalah :
∆TM = 164.0887469719 o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = water
Hot Fluid = medium organic

Range nilai U = 50 - 125 Btu/jam.ft2.F (kern. 840)


(diambil nilai 125 Btu/jam.ft2.F sebagai tebakan awal)
Ud = 125 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 11029649.166037 Btu/h
(125 Btu/ft2.oF.h)(164,088oF)
= 537.7407 ft2
= 49.95772 m2

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 8 BWG
Outside Diameter (OD) = 1.25 in 0.1041656083 ft
Inside Diameter (ID) = 0.92 in 0.0766658877 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 6 ft 1.8288 m
Flow area per tube (at') = 0.665 in2 0.00665 ft
luas permukaan luar (a'') = 0.3271 ft/ft 2

Number of tube (Nt) = Area = 537.741 ft2


L x a'' 6 ft x 0,3271 ft/ft2
= 273.994
Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 27 in dengan
jumlah tube sebesar 288 pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''

= 565.2288 ft2

Q
Ud =
A x ∆TM
11029649.17 Btu/h
=
(75,3984ft2) x 261,5 oF
= 118.9210178 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
288 x 0,355 (Eq 7.48 Kern,1965)
=
2
= 51.12 in2
= 0.355 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
1,224,688.36 lbm/h
=
0.355 ft2
= 3449826.36883046 lbm/h.ft2
3. Menentukan bilangan reynold (NRe)
NRe = Gt x ID
μ
= 3449826.369 lbm/h.ft2 x 0.0766658877 ft
1.820723 lbm/ft.h
= 145263.1892
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 220

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 7868.066 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)

= 5790.897

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 35 in = 2.9166370333 ft
B = Baffle Spacing (0,2 ID) 7 in 0.5833274067 ft
PT = Tube Pitch 1.5625 In 0.1302070104 ft
C = Clearench (PT-OD) 0.3125 In 0.0260414021 ft

Area of shell = 49 in2


(as) = 0.340278 ft2
2. Shell side Velocity
Shell side Velocity Mass flow
=
(Gs) area shell
119467.588003361 lbm/h
=
0.3402777778 ft2
= 351088.421887429 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
351088.4 lbm/h.ft2 X 2.9166370333 ft
=
1.5361210891 lbm/ft.h
= 666612.482888752

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 350

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 33259.8560116566 Btu/jam.oF

Menentukan Nilai Uc

Uc = 3335.7698763047 Btu/jam.oF
Menentukan Nilai Rd
= 0.0081091616

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.008109 > 0.003
maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 145263.189
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.10416561 ft
jumlah tube pass (n) = 1
Tube side velocity (Gt) = 3449826.37 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00013

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
= 1.1276344745 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g

s = 1 (tabel 27 Kern)

Dari figur 27 buku kern hal 837 , diperoleh V2


= 1
2g
∆P = 4x1 x 1
1

= 8 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 8 Psi + 1.1276344745 Psi
= 9.127634475 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi

b. Shell side
Diketahui ,
Wall thickness = 0.134 in 0.0111665532 ft
Bilangan Reynold (Nre) = 666612.5
Panjang Shell (L) = 6 ft
Diameter dalam (De) = 35 in = 2.9166370333 ft
Jumlah shell pass (n) = 1
Shell side velocity (Gs) = 351088.421887429 lbm/h
Baffle = 7 in 0.5833274067 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00008

s = 1

Banyaknya crosses,
12 L
N+1 =
B
12 x 6ft
=
0,16 ft
= 123.4298254781
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 2.9278035865 ft2

Maka pressur drop pada shell adalah ,


f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
∆Ps = 0.0234062676 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (E-203)
Nama Heat Exchanger
Kode E-203
Fungsi Mendinginkan Na2OSiO2 untuk umpan reaktor
Tipe Shell and Tube
Jumlah 1 Buah
Diameter Shell 0.89 m
Diameter Tube 0.03 m
Jumlah Tube 288
Panjang Tube 1.83 m
Fouling Factor (Rd) 0.008
Delta P (Shell) 0.16 kPa
Delta P (Tube) 62.93 kPa
HEATER (E-102)
Fungsi : Memanaskan H2SO4 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K) Cp.X (J/gK)
H2SO4 3829.02 0.41 1826.97 752.35 701.57 288.91
H2O 5469.20 0.59 1023.01 601.73 377.49 222.04
Total 9298.23 1 1354.08 510.94

Fluida Dingin (NaOH)


Massa = 9,298.23 kg/jam = 20499.2 lb/jam
T in = 30 C = 86 F
T out = 92.80 C = 199.04 F
Tave = 142.52 F
Tchange = 113.04 F
Cp = 510.94 J/gK
= 122.12 btu/lb F
k = 0.29436176 btu/hr ft F
densitas = 1354.08 kg/m3 84.355923 lb/ft3
viskositas = 19.7218794 cp 47.708968 lb/ft.h
(viskositas >1 cp, termasuk kedalam heavy organic, Kern 840)
Fluida Panas (udara dari rotary kiln)
Massa = 150,972.36 kg/jam = 332838.8197 lb/jam
T in = 211.25 C = 412.2502488 F
T out = 205.90 C = 402.6210663 F
Tave = 407.435658 F 208.57537 C
Tchange = 9.62918244 F 481.72537 K
Cp = 28136.60 J/gK
= 6721.83 btu/lb F
k = 907631.40 btu/hr ft F
densitas = 0.07958914 kg/m3 = 0.004958196 lb/ft3
viskositas = 0.00023595 cp 0.0005708 lbm/ft.h
(viskositas <0,5 cp, termasuk kedalam light organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 4,750,868.84 Kj/jam
= 1319685.78811803 j/s
= 4502971.26324097 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

(1357,01oF- 199,04oF) - (1352,63oF - 86oF)


∆TLMTD =
ln [(1357,01oF-199,04oF) / (1352,63oF - 86oF)]

= 261.5168865673 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two-four tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S= (t2-t1)
(t2-t1) (T1-t1)
= (1357F- 1352oF) = (199oF - 86oF)
(199oF - 86oF) ( 1357oF- 86oF)
= 0.09 = 0.346482494
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008). Ft = 1. Sehingga nilai ∆TM adalah

∆TM = 1 x 1211,489oF
= 261.5168865673 o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = light organic

Range nilai U = 30 - 60 Btu/jam.ft2.F (kern. 840)


(diambil nilai 100Btu/jam.ft2.F sebagai tebakan awal)
Ud = 30 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 4502971.26324097 Btu/h
(60 Btu/ft2.oF.h)(942,76oF)
= 573.9554 ft2
= 53.32218 m2
Karena luas area heat transfer 2m2 < A < 50 m2 , maka jenis HE yang digunakan adalah
double pipe. (Kern,1965)

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 10 BWG
Outside Diameter (OD) = 0.75 in 0.062499365 ft
Inside Diameter (ID) = 0.482 in 0.040166259 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 6 ft
Flow area per tube (at') = 0.182 in2 0.00182 ft
luas permukaan luar (a' = 0.1963 ft/ft2

Number of tube (Nt) = Area = 573.955 ft2


L x a'' 6 ft x 0,1963 ft/ft2
= 487.3115
Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 25 in dengan
jumlah tube sebesar 394 pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''
= 394 x 6 ft x 0,1963 ft
= 464.0532 ft2

Q
Ud =
A x ∆TM
4502971.26 Btu/h
=
(464,0532ft2) x 942,762 oF
= 37.1049343 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
394 x 0,182 (Eq 7.48 Kern,1965)
=
2
= 35.854 in2
= 0.248986 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
102,123.02 lbm/h
=
0.2489861111 ft2
= 410155.479142762 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe = Gt x ID
μ
= 410155.479 lbm/h.ft2 x 0.040166259 ft
47.708968 lbm/ft.h
= 345.310569
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 28

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 5550.616 Btu/jam.oF
6. Heat transfer coefisien pada tube (hio)

= 3567.196

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 25 in = 2.083312167 ft
B = Baffle Spacing (0,2 ID) 5 in 0.416662433 ft
PT = Tube Pitch 1 In 0.083332487 ft
C = Clearench (PT-OD) 0.25 In 0.020833122 ft

Area of shell = 25x 0,25 x 5


(as) 144 x 1
= 31.25 in2
= 0.217014 ft2

2. Shell side Velocity


Shell side Velocity Mass flow
=
(Gs) area shell
332838.819735293 lbm/h
=
0.2170138889 ft2
= 1533721.28134023 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
1533721 lbm/h.ft2 X 2.083312167 ft
=
0.0005707808 lbm/ft.h
= 9282.1168322326

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 55

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 403750.965594013 Btu/jam.oF

Menentukan Nilai Uc

Uc = 3535.9550506399 Btu/jam.oF
Menentukan Nilai Rd

= 0.0266677845

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.026668 > 0.003
maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 345.31057
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.0624994 ft
jumlah tube pass (n) = 2
Tube side velocity (Gt) = 410155.48 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00034

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
0,00034 x (41015595 lbm/h)2 x 6 ft x 2
=
5,22.1010 x 0,0625 ft x 1 x 1,514
= 0.1389585313 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g
s = spesific volume diukur pada T mean
= 1.514

Dari figur 27 buku kern hal 837 , diperoleh V2


= 0.015
2g
∆P = 4x2 x 0.015
1.514

= 0.0792602378 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.07926024 Psi + 0.138958531 Psi
= 0.21821877 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
b. Shell side
Diketahui ,
Wall thickness = 0.134 in 0.0111665532 ft
Bilangan Reynold (Nre = 9282.117
Panjang Shell (L) = 6 ft
Diameter dalam (De) = 25 in = 2.083312167 ft
Jumlah shell pass (n) = 2
Shell side velocity (Gs) = 1533721.28134023 lbm/h
Baffle = 5 in 0.417 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00022

s = spesific volume diukur pada T mean


= 1.5189
Banyaknya crosses,
12 L
N+1 =
B
12 x 6ft
=
0,417 ft
= 172.6618705036
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 2.0944787198 ft2

Maka pressur drop pada shell adalah ,


f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
0,00022 x (1533721,28lbm/h)2 x 2,0944 ft2 x 172,6618
∆Ps =
5,22.1010 x 2,0833 ft x 1 x 1,5189
= 1.1561331421 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (HE-104)
Nama Heat Exchanger
Kode HE-101
Fungsi Memanaskan NaOH untuk feed reaktor

Tipe Shell and Tube


Bahan
Jumlah 1 Buah
Dimensi
Diameter Shell 0.64 m
Diameter Tube 0.02 m
Jumlah Tube 394 m
Panjang Tube 1.8288 m
Fouling Factor (Rd) 0.0267
Delta P (Shell) 1.156 Psi
Delta P (Tube) 0.218 Psi
HEATER (E-102)
Fungsi : Memanaskan H2SO4 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K)Cp.X (J/gK)
H2SO4 3829.02 0.41 1826.97 752.35 701.57 288.91
H2O 5469.20 0.59 1023.01 601.73 377.49 222.04
Total 9298.23 1 1354.08 510.94

Fluida Dingin (NaOH)


Massa = 9,298.23 kg/jam = 20499.2 lb/jam
T in = 30 C = 86 F
T out = 92.80 C = 199.04 F
Tave = 142.52 F
Tchange = 113.04 F
Cp = 510.94 J/gK
= 122.12 btu/lb F
k = 0.29436176 btu/hr ft F
densitas = 1354.08 kg/m3 84.35592301 lb/ft3
viskositas = 19.7218794 cp 47.70896836 lb/ft.h
(viskositas >1 cp, termasuk kedalam heavy organic, Kern 840)
Fluida Panas (udara dari rotary kiln)
Massa = 150,972.4 kg/jam = 332838.8 lb/jam
T in = 211.25 C = 412.2502 F
T out = 205.90 C = 402.6211 F
Tave = 407.435658 F 208.5753653 C
Tchange = 9.62918244 F 481.7253653 K
Cp = 28136.60 J/gK
= 6721.83 btu/lb F
k = 907631.40 btu/hr ft F
densitas = 0.07958914 kg/m3 = 0.004958 lb/ft3
viskositas = 0.00023595 cp 0.000570781 lbm/ft.h
(viskositas <0,5 cp, termasuk kedalam light organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 4,750,868.84 Kj/jam
= 1319685.78811803 j/s
= 4502971.26324097 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
2,3 log [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

(1357,01oF- 199,04oF) - (1352,63oF - 86oF)


∆TLMTD =
2,3 log [(1357,01oF-199,04oF) / (1352,63oF - 86oF)]

= 261.8108193809 o
F
Menentukan Koefisien Overall Trial (Ud)
Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = light organic

Range nilai U = 30 - 60 Btu/jam.ft2.F (kern. 840)


(diambil nilai 30Btu/jam.ft2.F sebagai tebakan awal)
Ud = 30 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 4502971.26324097 Btu/h
(30 Btu/ft . F.h)(1212,85 F)
2 o o

= 573.3110742 ft2
= 53.26231873 m2
Karena luas area heat transfer 2m2 < A < 50 m2 , maka jenis HE yang digunakan adalah
double pipe. (Kern,1965)

Exchanger IPS (table 6.2 Kern, 110) : 4x3

Annulus (hot flluid)


Flow Area Annulus (Aa) = 3,14 in = 0.261666667 ft2 (tab. 6.2, Kern)
Mass Velocity (Ga)= Capacity (lb/hr) = 105999.6 lb/hr.ft2
ang digunakan adalah flow area
Diameter (De)= 1.14 0.095 ft

Nre = De x Ga = 211.7092381
Viskositas
Jh = 6 (fig.28, Kern)
Ho =

= 926871.8774 btu/hr.ft2.F
Inner Pipe (cold fluid)
D= 0.07125 ft (tab. 11, Kern)
Flow Area (Ap) = 7.38 = 0.615 ft2

Gp = capacity / Ap
= 33332.0188 lb/hr.ft2

Nre = D x Gp = 49.77903361
Viskositas

Jh = 23 (fig. 28 Kern)

Hi = = 2570.321666 btu/hr.ft2.F

Hio = Hi x (ID/OD)= 2932.244404

Uc (overall clean coeficient) =

= 1369.690291 btu/hr.ft2.F
1 = 1 + Rd
UD Uc
= 0.00073009 + 0.003
UD = 268.089898 btu/hr.ft2.F
A = 64.1550925 ft = 19.55447219 m2
Pressure Drop
Annulus
De' = 0,4 in = 0.03333333 ft
Friction Factor = 0,0035 + 0.264 (eq. 3.47 b, Kern)
Nre^0,42
= 0.03134795
∆Fa = 4 x f x Ga2 x L / 2 x g x ρ2 x De’
L = A / Surface per Lin (ft) (tab. 11, Kern)
L= 922.7579569 lin ft
g= 418000000 (Kern, hal.115)
∆Fa = 6.55615751 ft
∆Fl = 3 x V^2
2g'
V = Ga / 3600 x ρ
= 0.349048875 fps
g' = 32.2 (Kern, 115)
∆Fl = 0.00189185 ft

∆P = (∆Fa + ∆Fl) x ρ / 144


= 3.84173824 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi

Inner Pipe
Friction Factor = 0,0035 + 0.264 (eq. 3.47 b, Kern)
Nre^0,42
= 0.05464986
∆Fp = 4 x f x Gp2 x L / 2 x g x ρ2 x D
= 153045810.3

∆P = ∆Fp x ρ / 144
= 5269.661034 psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
RESUME (HE-104)
Nama Heat Exchanger
Kode HE-102
Fungsi Memanaskan H2SO4 untuk feed reaktor

Tipe Double Pipe


Bahan
Jumlah 1 Buah
Luas Area Transfer Panas 19.55 m2
Diameter Annulus 0.02896 m
Diameter Pipe 0.02172 m
UC 1369.69029 btu/hr.ft2.F
UD 268.0899 btu/hr.ft2.F
Delta P (Annulus) 3.842 Psi
Delta P (Pipe) 5269.661 Psi
Cp.X (J/gK)
g digunakan adalah
HEATER (E-102)
Fungsi : Memanaskan H2SO4 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K) Cp.X (J/gK)
H2SO4 3829.02 0.41 1826.97 752.35 701.57 288.91
H2O 5469.20 0.59 1023.01 601.73 377.49 222.04
Total 9298.23 1 1354.08 510.94

Fluida Dingin (NaOH)


Massa = 9,298.23 kg/jam = 20499.2 lb/jam
T in = 30 C = 86 F
T out = 92.80 C = 199.04 F
Tave = 142.52 F
Tchange = 113.04 F
Cp = 510.94 J/gK
= 122.12 btu/lb F
k = 0.29436176 btu/hr ft F
densitas = 1354.08 kg/m3 84.355923 lb/ft3
viskositas = 19.7218794 cp 47.708968 lb/ft.h
(viskositas >1 cp, termasuk kedalam heavy organic, Kern 840)
Fluida Panas (udara dari rotary kiln)
Massa = 150,972.36 kg/jam = 332838.8197 lb/jam
T in = 211.25 C = 412.2502488 F
T out = 205.90 C = 402.6210663 F
Tave = 407.435658 F 208.57537 C
Tchange = 9.62918244 F 481.72537 K
Cp = 28136.60 J/gK
= 6721.83 btu/lb F
k = 907631.40 btu/hr ft F
densitas = 0.07958914 kg/m3 = 0.004958196 lb/ft3
viskositas = 0.00023595 cp 0.0005708 lbm/ft.h
(viskositas <0,5 cp, termasuk kedalam light organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 4,750,868.84 Kj/jam
= 1319685.78811803 j/s
= 4502971.26324097 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

(1357,01oF- 199,04oF) - (1352,63oF - 86oF)


∆TLMTD =
ln [(1357,01oF-199,04oF) / (1352,63oF - 86oF)]

= 261.5168865673 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two-four tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S= (t2-t1)
(t2-t1) (T1-t1)
= (1357F- 1352oF) = (199oF - 86oF)
(199oF - 86oF) ( 1357oF- 86oF)
= 0.09 = 0.346482494
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008). Ft = 1. Sehingga nilai ∆TM adalah

∆TM = 1 x 1211,489oF
= 261.5168865673 o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = light organic

Range nilai U = 30 - 60 Btu/jam.ft2.F (kern. 840)


(diambil nilai 100Btu/jam.ft2.F sebagai tebakan awal)
Ud = 30 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 4502971.26324097 Btu/h
(60 Btu/ft2.oF.h)(942,76oF)
= 573.9554 ft2
= 53.32218 m2
Karena luas area heat transfer 2m2 < A < 50 m2 , maka jenis HE yang digunakan adalah
double pipe. (Kern,1965)

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 10 BWG
Outside Diameter (OD) = 0.75 in 0.062499365 ft
Inside Diameter (ID) = 0.482 in 0.040166259 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 6 ft
Flow area per tube (at') = 0.182 in2 0.00182 ft
luas permukaan luar (a' = 0.1963 ft/ft2

Number of tube (Nt) = Area = 573.955 ft2


L x a'' 6 ft x 0,1963 ft/ft2
= 487.3115
Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 25 in dengan
jumlah tube sebesar 394 pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''
= 394 x 6 ft x 0,1963 ft
= 464.0532 ft2

Q
Ud =
A x ∆TM
4502971.26 Btu/h
=
(464,0532ft2) x 942,762 oF
= 37.1049343 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
394 x 0,182 (Eq 7.48 Kern,1965)
=
2
= 35.854 in2
= 0.248986 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
102,123.02 lbm/h
=
0.2489861111 ft2
= 410155.479142762 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe = Gt x ID
μ
= 410155.479 lbm/h.ft2 x 0.040166259 ft
47.708968 lbm/ft.h
= 345.310569
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 28

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =
karena viskositas sangat rendah maka nilai φs = 1
hi = 5550.616 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)

= 3567.196

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 25 in = 2.083312167 ft
B = Baffle Spacing (0,2 ID) 5 in 0.416662433 ft
PT = Tube Pitch 1 In 0.083332487 ft
C = Clearench (PT-OD) 0.25 In 0.020833122 ft

Area of shell = 25x 0,25 x 5


(as) 144 x 1
= 31.25 in2
= 0.217014 ft2

2. Shell side Velocity


Shell side Velocity Mass flow
=
(Gs) area shell
332838.819735293 lbm/h
=
0.2170138889 ft2
= 1533721.28134023 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
1533721 lbm/h.ft2 X 2.083312167 ft
=
0.0005707808 lbm/ft.h
= 9282.1168322326
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 55

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 403750.965594013 Btu/jam.oF

Menentukan Nilai Uc

Uc = 3535.9550506399 Btu/jam.oF
Menentukan Nilai Rd

= 0.0266677845

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.026668 > 0.003
maka spesifikasi heater dapat diterima
Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 345.31057
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.0624994 ft
jumlah tube pass (n) = 2
Tube side velocity (Gt) = 410155.48 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00034

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
0,00034 x (41015595 lbm/h)2 x 6 ft x 2
=
5,22.1010 x 0,0625 ft x 1 x 1,514
= 0.1389585313 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g
s = spesific volume diukur pada T mean
= 1.514

Dari figur 27 buku kern hal 837 , diperoleh V2


= 0.015
2g
∆P = 4x2 x 0.015
1.514

= 0.0792602378 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.07926024 Psi + 0.138958531 Psi
= 0.21821877 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
b. Shell side
Diketahui ,
Wall thickness = 0.134 in 0.0111665532 ft
Bilangan Reynold (Nre = 9282.117
Panjang Shell (L) = 6 ft
Diameter dalam (De) = 25 in = 2.083312167 ft
Jumlah shell pass (n) = 2
Shell side velocity (Gs) = 1533721.28134023 lbm/h
Baffle = 5 in 0.417 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00022

s = spesific volume diukur pada T mean


= 1.5189
Banyaknya crosses,
12 L
N+1 =
B
12 x 6ft
=
0,417 ft
= 172.6618705036
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 2.0944787198 ft2

Maka pressur drop pada shell adalah ,


f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
0,00022 x (1533721,28lbm/h)2 x 2,0944 ft2 x 172,6618
∆Ps =
5,22.1010 x 2,0833 ft x 1 x 1,5189
= 1.1561331421 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)


RESUME (HE-104)
Nama Heat Exchanger
Kode HE-101
Fungsi Memanaskan NaOH untuk feed reaktor

Tipe Shell and Tube


Bahan
Jumlah 1 Buah
Dimensi
Diameter Shell 0.64 m
Diameter Tube 0.02 m
Jumlah Tube 394 m
Panjang Tube 1.8288 m
Fouling Factor (Rd) 0.0267
Delta P (Shell) 1.156 Psi
Delta P (Tube) 0.218 Psi
Cooler (E-103)
Fungsi : Memanaskan H2SO4 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K)Cp.X (J/gK)
Na2SiO3 10,793.14 0.20 2,416.00 481.21 1973.59 393.09
H2O 43396.16386 0.80082528 1023.012987 819.25 377.49 302.30
Total 54189.30 1 1300.46 695.39

Fluida Dingin (Air)


Massa = 555,506.39 kg/jam = 1224688 lb/jam
T in = 30.00 C = 86 F
T out = 35.01 C = 95.01223 F
Tave = 90.51 F
Tchange = 9.01 F
Cp = 377.49 J/gK
= 90.22 btu/lb F
k = 0.35 btu/hr ft F
densitas = 1,023.01 kg/m3 63.73104927 lb/ft3
viskositas = 0.75 cp 1.820722803 lb/ft.h

Fluida Panas (Sodium Silikat)


Massa = 54,189.3 kg/jam = 119467.6 lb/jam
T in = 162.0 C = 323.6 F
T out = 92.8 C = 199.04 F
Tave = 261.3 F 127.4 C
Tchange = 124.6 F 400.55 K
Cp = 695.4 J/gK
= 166.1 btu/lb F
k = 49.0 btu/hr ft F
densitas = 1,300.5 kg/m3 = 81.01533 lb/ft3
viskositas = 0.6 cp 1.536121089 lbm/ft.h
(viskositas 0,5-1 cp, termasuk kedalam medium organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 13574.5799937224 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
2,3 log [ (T1-t2)/(T2-t1)]
Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet
(1357,01oF- 199,04oF) - (1352,63oF - 86oF)
∆TLMTD =
2,3 log [(1357,01oF-199,04oF) / (1352,63oF - 86oF)]
= 164.2731750894 o
F
Menentukan Koefisien Overall Trial (Ud)
Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = Water
Hot Fluid = light organic

Range nilai U = 50 - 125 Btu/jam.ft2.F (kern. 840)


(diambil nilai 50 Btu/jam.ft2.F sebagai tebakan awal)
Ud = 50 Btu/jam.ft2.F
Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 13574.5799937224 Btu/h
(30 Btu/ft2.oF.h)(1212,85oF)
= 1.652683706 ft2
= 0.153539274 m2
Karena luas area heat transfer 2m2 < A < 50 m2 , maka jenis HE yang digunakan adalah
double pipe. (Kern,1965)

Exchanger IPS (table 6.2 Kern, 110) : 4x3

Annulus (hot flluid)


Flow Area Annulus (Aa) = 3,14 in = 0.261666667 ft2 (tab. 6.2, Kern)
Mass Velocity (Ga)= Capacity (lb/hr) = 105999.6 lb/hr.ft2
flow area
Diameter (De)= 1.14 0.095 ft

Nre = De x Ga = 211.7092381
Viskositas
Jh = 6 (fig.28, Kern)

Ho =

= 926871.8774 btu/hr.ft2.F
Inner Pipe (cold fluid)
D= 0.07125 ft (tab. 11, Kern)
Flow Area (Ap) = 7.38 = 0.615 ft2

Gp = capacity / Ap
= 33332.0188 lb/hr.ft2

Nre = D x Gp = 49.77903361
ang digunakan adalah Viskositas

Jh = 23 (fig. 28 Kern)

Hi = = 2570.321666 btu/hr.ft2.F
Hio = Hi x (ID/OD)= 2932.244404

Uc (overall clean coeficient) =

= 1369.690291 btu/hr.ft2.F
1 = 1 + Rd
UD Uc
= 0.00073009 + 0.003
UD = 268.089898 btu/hr.ft2.F
A = 0.30823312 ft = 0.093949454 m2
Pressure Drop
Annulus
De' = 0,4 in = 0.03333333 ft
Friction Factor = 0,0035 + 0.264 (eq. 3.47 b, Kern)
Nre^0,42
= 0.03134795
∆Fa = 4 x f x Ga2 x L / 2 x g x ρ2 x De’
L = A / Surface per Lin (ft) (tab. 11, Kern)
L= 922.7579569 lin ft
g= 418000000 (Kern, hal.115)

∆Fa = 6.55615751 ft

∆Fl = 3 x V^2
2g'
V = Ga / 3600 x ρ
= 0.349048875 fps
g' = 32.2 (Kern, 115)
∆Fl = 0.00189185 ft

∆P = (∆Fa + ∆Fl) x ρ / 144


= 3.84173824 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
Inner Pipe
Friction Factor = 0,0035 + 0.264 (eq. 3.47 b, Kern)
Nre^0,42
= 0.05464986
∆Fp = 4 x f x Gp2 x L / 2 x g x ρ2 x D
= 153045810.3

∆P = ∆Fp x ρ / 144
= 5269.661034 psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
RESUME (HE-104)
Nama Heat Exchanger
Kode HE-102
Fungsi Memanaskan H2SO4 untuk feed reaktor

Tipe Double Pipe


Bahan
Jumlah 1 Buah
Luas Area Transfer Panas 0.09 m2
Diameter Annulus 0.02896 m
Diameter Pipe 0.02172 m
UC 1369.69029 btu/hr.ft2.F
UD 268.0899 btu/hr.ft2.F
Delta P (Annulus) 3.842 Psi
Delta P (Pipe) 5269.661 Psi
Cp.X (J/gK)
g digunakan adalah
Cooler (E-103)
Fungsi : Mendinginkan Na2SiO3 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K) Cp.X (J/gK)
Na2SiO3 10793.14 0.20 2416.00 481.21 111.80 22.27
H2O 43396.16 0.80 1023.01 819.25 377.49 302.30
Total 54189.30 1 1300.46 324.57

Fluida Dingin (Air)


Massa = 555,506.39 kg/jam = 1224688.4 lb/jam
T in = 30 C = 86 F
T out = 35.01 C = 95.01223114 F
Tave = 90.5061156 F
Tchange = 9.01223114 F
Cp = 377.49 J/gK
= 90.22 btu/lb F
k = 0.35424172 btu/hr ft F
densitas = 1023.01 kg/m3 63.731049 lb/ft3
viskositas = 0.75264833 cp 1.8207228 lb/ft.h

Fluida Panas (Na2SiO3)


Massa = 54,189.30 kg/jam = 119467.588 lb/jam
T in = 162.00 C = 323.6 F
T out = 92.80 C = 199.04 F
Tave = 261.32 F 127.4 C
Tchange = 124.56 F 400.55 K

Cp = 1.55 btu/lb F
k = 49.00 btu/hr ft F
densitas = 1300.46 kg/m3 = 81.01532587 lb/ft3
viskositas = 0.635 cp 1.5361211 lbm/ft.h
(viskositas 0,5-1 cp, termasuk kedalam medium organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 185174.76140521 Btu/h

Menentukan ∆TLMTD Dan ∆TM


Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

(1357,01oF- 199,04oF) - (1352,63oF - 86oF)


∆TLMTD =
ln [(1357,01oF-199,04oF) / (1352,63oF - 86oF)]

= 164.0887469719 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two-four tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S= (t2-t1)
(t2-t1) (T1-t1)
= (1357F- 1352oF) = (199oF - 86oF)
(199oF - 86oF) ( 1357oF- 86oF)
= 13.82 = 0.037930266
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008). Ft = 0,97. Sehingga nilai ∆TM adalah

∆TM = 1 x 1211,489oF
= 159.1660845627 o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = light organic

Range nilai U = 30 - 60 Btu/jam.ft2.F (kern. 840)


(diambil nilai 100Btu/jam.ft2.F sebagai tebakan awal)
Ud = 50 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 185174.76140521 Btu/h
(60 Btu/ft2.oF.h)(942,76oF)
= 22.57007 ft2
= 2.096828 m2
Karena luas area heat transfer 2m2 < A < 50 m2 , maka jenis HE yang digunakan adal
double pipe. (Kern,1965)

Menentukan Jumlah Tube (Nt)


Dipilih spesifikasi tube heat exchanger berdasaarkan tabel 10 (Kern..) , yaitu
sebagai berikut :
Dipilih jenis tube 10 BWG
Outside Diameter (OD) = 0.75 in 0.062499365 ft
Inside Diameter (ID) = 0.482 in 0.040166259 ft
Range Lenght of Tube = 6 ft - 24 ft
Lenght of tube = 6 ft
Flow area per tube (at') = 0.182 in2 0.00182 ft
luas permukaan luar (a' = 0.1963 ft/ft2

Number of tube (Nt) = Area = 22.570 ft2


L x a'' 6 ft x 0,1963 ft/ft2
= 19.16291
Koreksi Nilai Luas Area Transfer Panas (A) dan Nilai (Ud)
Berdasarkan Tabel 9. (kern,1983). Dengan menggunakan Tube arrangement
square pitch. nilai jumlah tube terdekat didapati pada ID Shell 25 in dengan
jumlah tube sebesar 394 pada jarak antar tube (PT) = 1 in dan 2 tube pass
A = Nt x L x a''
= 394 x 6 ft x 0,1963 ft
= 464.0532 ft2

Q
Ud =
A x ∆TM
185174.761 Btu/h
=
(464,0532ft2) x 942,762 oF
= 2.50705285 Btu/jam.ft2.F
(masih memasuki batas yang diizinkan)

Perancangan HE
a. Tube
1. Luas Area per tube
Area of one tube
Nt . at'
(at) =
n
394 x 0,182 (Eq 7.48 Kern,1965)
=
2
= 35.854 in2
= 0.248986 ft2
2. Tube side Velocity
Tube side Velocity
(Gt) Mass flow
=
area per pass
102,123.02 lbm/h
=
0.2489861111 ft2
= 410155.479142762 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe = Gt x ID
μ
= 410155.479 lbm/h.ft2 x 0.040166259 ft
1.820723 lbm/ft.h
= 9048.28072
4. Heat transfer factor (jh)
Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah (Fig.28)
Heat transfer factor (jh) = 28

5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 1911.367 Btu/jam.oF

6. Heat transfer coefisien pada tube (hio)


= 1228.372

a. Shell
1. Luas Area shell

Dimana,
De = Diamter dalam shell = 25 in = 2.083312167 ft
B = Baffle Spacing (0,2 ID) 5 in 0.416662433 ft
PT = Tube Pitch 1 In 0.083332487 ft
C = Clearench (PT-OD) 0.25 In 0.020833122 ft

Area of shell = 25x 0,25 x 5


(as) 144 x 1
= 31.25 in2
= 0.217014 ft2

2. Shell side Velocity


Shell side Velocity Mass flow
=
(Gs) area shell
119467.588003361 lbm/h
=
0.2170138889 ft2
= 550506.645519488 lbm/h.ft2

3. Menentukan bilangan reynold (NRe)


NRe Gs x De
=
μ
550507 lbm/h.ft2 X 2.083312167 ft
=
1.5361210891 lbm/ft.h
= 3331.6790102613

4. Heat transfer factor (jh)


Taksir jh pada nilai Nre yang didapat, sehingga nilai jh adalah
Heat transfer factor (jh) = 55
5. Menentukan nilai (hi)

Dimana,
jh = Heat transfer factor
k = Thermal conductivity , Btu/h.ft.oF
IDs = Diameter dalam shell (ft)
Cp = Kapasitas panas, Btu/lbm.oF
μ = Viskositas fluida, lbm/ft.h
φ =

karena viskositas sangat rendah maka nilai φs = 1


hi = 476.8365886935 Btu/jam.oF

Menentukan Nilai Uc

Uc = 343.4962245317 Btu/jam.oF
Menentukan Nilai Rd

= 0.3959634786

Dari buku kern hal 845, diperoleh nilai Rd min adalah 0,003
Rd > Rd min. 0.395963 > 0.003
maka spesifikasi heater dapat diterima

Pressure Drop
a. Tube side
Diketahui ,
Bilangan Reynold Nre = 9048.2807
Panjang tube (L) = 6 ft
Diameter dalam (ID) = 0.0624994 ft
jumlah tube pass (n) = 2
Tube side velocity (Gt) = 410155.48 lbm/h

Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00034

1. menghitung ∆P karena panjang pipa


∆Ps = f x Gt2 x L x n
5,22.1010 x IDt x φ x s
0,00034 x (41015595 lbm/h)2 x 6 ft x 2
=
5,22.1010 x 0,0625 ft x 1 x 1,514
= 0.1389585313 psia

2. menghitung ∆P karena tube pass


∆Pr = 4n x V2
Dimana, s 2g
s = spesific volume diukur pada T mean
= 1.514

Dari figur 27 buku kern hal 837 , diperoleh V2


= 0.015
2g
∆P = 4x2 x 0.015
1.514

= 0.0792602378 Psi

3. Total pressure drop pada tube


∆PT = ∆PS + ∆Pr
= 0.07926024 Psi + 0.138958531 Psi
= 0.21821877 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
b. Shell side
Diketahui ,
Wall thickness = 0.134 in 0.0111665532 ft
Bilangan Reynold (Nre = 3331.679
Panjang Shell (L) = 6 ft
Diameter dalam (De) = 25 in = 2.083312167 ft
Jumlah shell pass (n) = 2
Shell side velocity (Gs) = 550506.645519488 lbm/h
Baffle = 5 in 0.417 ft
f x Gts2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
Dari figur 26 hal 836, diperoleh nilai Friction Factor (F) = 0.00022

s = spesific volume diukur pada T mean


= 1.5189
Banyaknya crosses,
12 L
N+1 =
B
12 x 6ft
=
0,417 ft
= 172.6618705036
Diameter luar shell (Ds),
Ds = De + Wall Thickness

= 2.0944787198 ft2

Maka pressur drop pada shell adalah ,


f x Gs2 x Ds x (N+1)
∆Ps =
5,22.1010 x De x φ x s
0,00022 x (1533721,28lbm/h)2 x 2,0944 ft2 x 172,6618
∆Ps =
5,22.1010 x 2,0833 ft x 1 x 1,5189
= 0.1489498587 Psi

∆Ps yang diperbolehkan < 10 psi (memenuhi)

RESUME (HE-104)
Nama Heat Exchanger
Kode HE-101
Fungsi Memanaskan NaOH untuk feed reaktor
Tipe Shell and Tube
Bahan
Jumlah 1 Buah
Dimensi
Diameter Shell 0.64 m
Diameter Tube 0.02 m
Jumlah Tube 394 m
Panjang Tube 1.8288 m
Fouling Factor (Rd) 0.3960
Delta P (Shell) 0.149 Psi
Delta P (Tube) 0.218 Psi
HEATER (E-102)
Fungsi : Memanaskan H2SO4 sebelum masuk ke reaktor Precipitated Silica
INPUT
Aliran Massa X densitas campuran Cp (J/g K)Cp.X (J/gK)
H2SO4 3829.02 0.07 2416.00 170.71 701.57 49.57
H2O 5469.20 0.10 1023.01 103.25 377.49 38.10
Total 9298.23 0.17158789 273.97 87.67

Fluida Dingin (NaOH)


Massa = 9,298.23 kg/jam = 20499.2 lb/jam
T in = 30 C = 86 F
T out = 92.80 C = 199.04 F
Tave = 142.52 F
Tchange = 113.04 F
Cp = 87.67 J/gK
= 20.95 btu/lb F
k = 0.35424172 btu/hr ft F
densitas = 273.97 kg/m3 17.06732621 lb/ft3
viskositas = 0.75264833 cp 1.820722803 lb/ft.h
(viskositas >1 cp, termasuk kedalam heavy organic, Kern 840)
Fluida Panas (udara dari rotary kiln)
Massa = 150,972.4 kg/jam = 332838.8 lb/jam
T in = 211.25 C = 412.2502 F
T out = 205.90 C = 402.6211 F
Tave = 407.435658 F 208.5753653 C
Tchange = 9.62918244 F 481.7253653 K
Cp = 28136.60 J/gK
= 6721.83 btu/lb F
k = 49.00 btu/hr ft F
densitas = 1300.46079 kg/m3 = 81.01533 lb/ft3
viskositas = 0.635 cp 1.536121089 lbm/ft.h
(viskositas <0,5 cp, termasuk kedalam light organic, Kern 840)
Panas yang terserap
Q cold = Q hot = Q
Q yang dibutuhkan
= 815,191.57 Kj/jam
= 226442.102212238 j/s
= 772655.345863575 Btu/h
Menentukan ∆TLMTD Dan ∆TM
Aliran yang digunakan adalah counter current sehingga,
(T1-t2) - (T2-t1)
∆TLMTD =
ln [ (T1-t2)/(T2-t1)]

Dimana,
T1 = Temperatur fluida panas inlet
T2 = Temperatur fluida panas ounlet
t1 = Temperatur fluida dingin iunlet
t2 = Temperatur fluida dingin ounlet

(1357,01oF- 199,04oF) - (1352,63oF - 86oF)


∆TLMTD =
ln [(1357,01oF-199,04oF) / (1352,63oF - 86oF)]

= 261.5168865673 o
F

∆TM = Ft x ∆TLMTD

Dimana,
∆TM = Perubahan temperatur sebenarnya
Ft = Faktor koreksi temperatur
Untuk mendapatkan nilai Ft maka diperlukan nilai R dan S. Ft didapatkan pada
grafik 12.20 atau dari persamaan 12.6 dan 12.7 (Towler,2008) dan menggunakan
one shell two-four tube pass/ 1 shell pass 2 tube pass
R = (T1-T2) S = (t2-t1)
(t2-t1) (T1-t1)
= (1357F- 1352oF) = (199oF - 86oF)
(199oF - 86oF) ( 1357oF- 86oF)
= 0.09 = 0.346482
Syarat design Heat exchanger yang ekomis apabila Ft diatas 0,75, didapatkan
nilai Ft sebesar grafik 12.19 (Towler,2008). Ft = 1. Sehingga nilai ∆TM adalah

∆TM = 1 x 1211,489oF
= 261.5168865673 o
F

Menentukan Koefisien Overall Trial (Ud)


Dari tabel 8 hal 840 (kern,1983), Nilai U untuk jenis fluida tersebut adalah
Cold Fluid = heavy organic
Hot Fluid = light organic

Range nilai U = 50 - 125 Btu/jam.ft2.F (kern. 840)


(diambil nilai 30Btu/jam.ft2.F sebagai tebakan awal)
Ud = 50 Btu/jam.ft2.F

Menentukan Luas Area Transfer Panas (A)

A = Q
Ud x ∆TM
= 772655.345863575 Btu/h
(30 Btu/ft2.oF.h)(942,76oF)
= 59.09028331 ft2
= 5.48966459 m2
Karena luas area heat transfer 2m2 < A < 50 m2 , maka jenis HE yang digunakan adalah
double pipe. (Kern,1965)

Exchanger IPS (table 6.2 Kern, 110) : 4x3

Annulus (hot flluid)


Flow Area Annulus (Aa) = 3,14 in = 0.261666667 ft2 (tab. 6.2, Kern)
Mass Velocity (Ga)= Capacity (lb/hr) = 38047 lb/hr.ft2
flow area
Diameter (De)= 1.14 0.095 ft

Nre = De x Ga = 0.028235784
Viskositas

Jh = 6 (fig.28, Kern)

Ho =

= 1129.303693 btu/hr.ft2.F

Inner Pipe (cold fluid)


D= 0.07125 ft (tab. 11, Kern)
Flow Area (Ap) = 7.38 = 0.615 ft2

Gp = capacity / Ap
= 1991363.189 lb/hr.ft2

Nre = D x Gp = 77927.63783
Viskositas

Jh = 23 (fig. 28 Kern)

Hi = = 885.096135 btu/hr.ft2.F

Hio = Hi x (ID/OD)= 1009.725056

Uc (overall clean coeficient) =

= 471.6559794 btu/hr.ft2.F
1 = 1 + Rd
UD Uc
= 0.00212019 + 0.003
UD = 195.305276 btu/hr.ft2.F
A = 15.1276721 ft = 4.610914445 m2
Pressure Drop
Annulus
De' = 0,4 in = 0.03333333 ft
Friction Factor = 0,0035 + 0.264 (eq. 3.47 b, Kern)
Nre^0,42
= 1.1845492
∆Fa = 4 x f x Ga2 x L / 2 x g x ρ2 x De’
L = A / Surface per Lin (ft) (tab. 11, Kern)
L= 36.28629325 lin ft
g= 418000000 (Kern, hal.115)
∆Fa = 2.198920039 ft
∆Fl = 3 x V^2
2g'

V = Ga / 3600 x ρ
= 0.165831442 fps
g' = 32.2 (Kern, 115)
∆Fl = 0.00042702 ft

∆P = (∆Fa + ∆Fl) x ρ / 144


= 0.97337983 Psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi

Inner Pipe

Friction Factor = 0,0035 + 0.264 (eq. 3.47 b, Kern)


Nre^0,42
= 0.00582859

∆Fp = 4 x f x Gp2 x L / 2 x g x ρ2 x D
= 8.581075565

∆P = ∆Fp x ρ / 144
= 4.827768286 psi
∆PT yang diizinkan < 10 psi, maka syarat terpenuhi
RESUME (HE-104)
Nama Heat Exchanger
Kode HE-102
Fungsi Memanaskan H2SO4 untuk feed reaktor

Tipe Double Pipe


Bahan
Jumlah 1 Buah
Luas Area Transfer Panas 4.61 m2
Diameter Annulus 0.02896 m
Diameter Pipe 0.02172 m
UC 471.65598 btu/hr.ft2.F
UD 195.3053 btu/hr.ft2.F
Delta P (Annulus) 0.973 Psi
Delta P (Pipe) 4.828 Psi
Cp.X (J/gK)
g digunakan adalah
t= 30 C 303 k

Komponen A B C

NaOH -4.1939 2051.5 0.0027917


H2O -10.2518 1792.5 0.018
H2SO4 -18.7045 3496.2 0.033

Komponen A B n

NaOH 0.19975 0.09793 0.25382


H2O 0.3471 0.274 0.286
H2SO4 0.42169 0.19356 0.286
t=
-6.159E-07 -0.000006159
konduktivtas termal gas
μ
D Komponen
cp
-0.00006159 0.0058626754 3,690.17 0.079662941 0.000467 CO2
-0.000012631 0.7526483349 42,632.11 0.920337059 0.69269 H2O
-0.0000170 19.721879429 46,322.28 cp 0.693157 SO2
lbm.h/ft 1.676817 N2
Density
Tc
g/ml kg/m3 T=162 435
2820 5.4771233654 5477.123 1.85165417 1851.654
647.13 1.0230129872 1023.013 0.889767391 889.7674
925.00 1.8269712339 1826.971
92.80 365.80 1.8819412964 1881.941 0.000001564
0.9629867891 962.9868 0.277909336
1.7484823779 1748.482 4.749778309

coulson, 817 8.12 0.4427067


H2O 350 623.15 8.56
densitas 0.58 g/ml 575.11 kg/m3
k 0.0491170569 w/mk 0.028379 btuh/ftf
viscos 0.06 cp 211.15 484.30
densitas 0.83 g/ml 830.85 kg/m3
k 0.0349589185 w/mk 0.020199 btuh/ftf
viscos 0.12 cp

alasan pemilihan bucket elevator perry page 21-13


dipilih spaced-bucket centrifugal discharge elevator krna utk material yg free flowing
spaced bucket positive discharge elevator utk material sticky
continous bucket elevator utk material yang tidak dapat dihandel oleh discharge elevator
supercapacity continuous bucket utk kapasitas besar (high lifts and large lumps)

pemilihan grade carbon steel 283 C ada di brownel young page 79


pemilihan agitator
geankoplis 142
vtas termal gas T= 800 C 1073 K
k
Komponen A B C
w/m.K
CO2 -0.01183 10174 -2.2242E-08 10916701.963
H2O 0.00053 0.000047093 4.955E-08 0.108
SO2 -2.9905 2.6266 781 899190764.351
N2 0.00309 0.00007593 -0.000000011 0.072
Total
konduktivitas termal (k) = 4522993.67794334
h2o = 2613344.47195307
konduktivitas termal liquid / solid T= 30 C 303 K

Komponen A B C

NaOH -3.2252 0.0040045 5.0633E-06


H2O -0.2758 0.004612 -5.5391E-06
H2SO4 0.1553 0.0010699 -1.2858E-06
H2O -0.2758 0.004612 -5.5391E-06
Total
konduktivitas termal (k)

Viskositas cairan (µ) = 2.448 cP


HYSYS = 0.0245 kg/m.s
=

konduktivtas termal gas T=


k
4926760.88905
0.0349541774
183144360.291
0.0372763499

0.0833 0.0254
type of fitting and valve LE/ID (in) ft m
elbow 45 17 1.4161 0.4318
elbow 90 35 2.9155 0.889 CS = CP / Sg
tee 50 4.165 1.27
return bend 75 6.2475 1.905 NaOH
coupling 2 0.1666 0.0508 H2SO4
union 2 0.1666 0.0508 Na2sio3
gate valve wide open 9 0.7497 0.2286
gate valve half open 225 18.7425 5.715
globe valve wide 300 24.99 7.62
globe valve half 475 39.5675 12.065
angle valve 100 8.33 2.54
check valve 0 0
ball 3500 291.55 88.9
swing 100 8.33 2.54
water meter 350 29.155 8.89
yi k.yi
viscosity gas 800
0.240 2623433.71075351 11.336 0.49918 -0.0001088
0.099 0.0107077882 -36.826 0.429 -0.0000162
0.002 1899559.90914566 -11.103 0.502 -0.000108
0.659 0.0473363829 42.606 0.475 -0.0000988
4522993.67794334
4522993.67794334 W/m.K
2613344.47195307 Btu.h/ft.F

k bahan
C yi k.yi
w/m.K CO2
5.0633E-06 -1.547 0.038 -0.0580117496 H2O
-5.5391E-06 0.613 0.963 0.5901056393 SO2
-1.2858E-06 0.361 0.412 0.1488380969 N2
-5.5391E-06 0.613 0.588 0.3606226235
1.0415546101
= 0.5320938897 W/m.K 0.509461
= 0.3074389938 Btu.h/ft.F 0.294362
h2so4 = 0.509461 w/mk
= 0.294362 btuh/ft/f 0.354242

211.25 C 484.2501 K
y
0.240 1183968.4408 vapour pressure 162 435.15
0.099 0.0034620748 al2o3 14.16 -0.000282 -0.7384
0.002 386896.41641 MgO -41.27 -14020 15.39
0.659 0.024547506 NaOH -48.277 -1934 17
1570864.8852 W/m.k H2O 29.8 -0.0035 -7.3037
907631.39554 btu.h/ft.F SiO2 -378.521 6540 131.5
Na2OSO3 -2.2687 -15051 3.5
H2so4 2.0582 -4190 3.257

92.8 365.95
sg cp viskositas cs h2o 11.31979 0.78 8.79237443
1.52 2.448 1.610526 sio2 -36.1659 0.11 -4.0965045
1.85 19.721879429 10.66048 na2oso3 -33.9368 0.02 -0.5842803
1.39 5.53 3.978417 h2so4 -410597 0.00 -426.75587
4.11158958
panas jenis
h2o
736.12
0.0004217 0.000101 0.000228 5.468578997E-05
0.0004048 4.01E-05 0.000167 1.655242866E-05
0.0004032 8.52E-07 0.000207 4.365837776E-07
0.0004385 0.000289 0.000249 0.0001642739
0.000 cp 0.0002359487 cp
0.000 lbm/ft 0.0005707836 lbm/ft

densitas gas
mol fraksi BM BM gas
0.00 0.240 0.00 0
5,000.00 0.099 18.00 1.782829702
0.00 0.002 0.00 0
0.00 0.659 0.00 0
1.000 1.782829702
R= 8314 kj/kmolk
ρ vapour = P x BM
RxT
= 0.039236

ρ vapour = 0.079589

Pvap x x
-0.000000374 2.308E-11 12.21147 0.00 0.016227
-0.0023614 1.1265E-07 -33.8864 0.00 -0.05022
2.964E-11 0.000000875 -7.6989 0.01 -0.04067 0.00541473 -0.04169
-2.424E-09 0.000001809 10.87071 0.78 8.44965 0.80 8.66011
-0.0357 0.000003422 -31.3976 0.01 -0.39877
0.00127 0.000000177 -27.0354 0.19 -5.2213 0.20 -5.35135
-1122 5.537E-07 -488237 Pvap 2.754908 0.440107 3.267071
Pompa 01 (P-201)
Fungsi : memompa fresh feed h2so4 dari storage tank menuju dissolver tank
Jenis : Centrifugal
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 unit cadangan

F ρ camp µ µ camp
Komponen X ρ
(Kg/Jam) (Kg/m3) (cp) (cp)
sulfat 3829.02 0.89 1827 1627.56 19.7 17.57
air 469.14 0.11 1023 111.66 0.75 0.08
Total 4298.17 1.00 1739.22 17.65

1. Menentukan Laju Alir Cairan


Laju Alir massa Total, ṁ = 2.63 lbm/s
Densitas, ρ = 108.6 lbm/ft3
Laju Alir , Q Q = ṁ/ρ = (2,42
�𝑏𝑚/�)/(91,61 �𝑏𝑚/��)
= 0.024 ft3/s
= 10.88 gal/min (gpm)
= 0.001 m3/s 2.47
Faktor Keamanan 20% Q x 1.2
Q = 0.001 m3/s
0.03 ft3/s
2. Menentukan diameter optimum pipa

Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)


Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)

Diameter optimum pipa = 0.039 m


1.543 In

sehingga dipilih Nominal Pipe Size (NPS)


NPS = 1 1/2 in (Geankoplis, App. A-5)
Schedule Numb. = 40
OD = 1.90 in
= 48.26 mm
= 0.048 m
Inside Diameter = 1.61 in
= 40.89 mm
= 0.041 m
= 0.134 ft
Luas penampang inside, A = 0.01 ft2
= 0.001 m2

Kecepatan linier dalam pipa, v �=𝑄/�

v = 0.627 m/s
2.058 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 17.65 cp


0.018 Kg/m.s
0.018 Pa.s
NRe = ρ�𝐷/µ
NRe = (1467,40 𝑘𝑔/(𝑚3 ) 𝑥 0,68
𝑚/� 𝑥 0,04 𝑚)/(0,01 𝑘𝑔/𝑚.�)

Nre = 2528.12

Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa


10 m
Asumsi panjang total, L
32.81 ft
(Geankoplis, tab.2.10-1)
Gate Vale full open = 0.10 ft
1Gate Valve (GV) = 0.10 ft
Elbow 90 = 0.39 ft
2 Elbow 90 = 1.56 ft
Le = 1.67 ft
∆L = L + Le = 34.47 ft

Nre = 2528.12 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.001124969

f = 0.013 (Geankoplis, fig.2.10-3)

5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 1.03 ft.lbf/lbm
6. Menghitung Head Pompa (H)

H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk


Turbulent Flow

Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

9,5
1m

0.5 m ∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� + ∑F =


-Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2
mencari ∆P dengan ∆z = 9.51 - 0.5 = 9.01 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 153570.65 N/m2
22.27 psia
1.52 atm

z1 = 0.50 m
1.64 ft
z2 = 9.51 m (Tinggi mixer tank )
31.20 ft

∆P = 1.52 atm
22.27 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 33.94 ft
35 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 34.963 ft.lbf/lbm SI


(-Ws) = 104.50 J/Kg English

8. Menghitung Daya Pompa (Wp)


Efisiensi pompa, Ƞ = 30 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)

BHP = 0.56 HP
0.42 kW
Efisiensi motor, Ƞe = 80 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor = 0.52 kW
0.70 HP
maka, dipilih motor listrik = 1 Hp
= 1 HP x 0.7457
= 0.746 kW
9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)
= 〖 3500 𝑥 11,88 〗 ^0,5/
〖 7900 〗 ^(4/3)
NPSH = 0.07 ft
= 0.02 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 1739.22 kg/m3
v = 0.017649 kg/ms
z1 = -0.50 m
Pvp = 13.112 mmHg 1.7481 Kpa
ƩF = 1.03 ft = 0.3127 m
9.8 x NPSHa = 49.29
NPSHa = 5.029 m
NPSHa > NPSHr
POMPA (P-201)
Kode : P-201 A/B
Jumlah : 2 buah
Fungsi : Sebagai alat transportasi dari tangki penyimpanan H2SO4
menuju mixer
Tipe : Pompa sentrifugal
Kapasitas : 2.47 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 1 HP
NPSH : 0.02 m
Ukuran Pipa : 1 1/2 in Sch Number 40
Bahan Pipa : Commercial Steel
Pompa 02 (P-202)
Fungsi : memompa fresh feed NaOH dari storage tank menuju ke dissolver
Jenis : Centrifugal
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 cadangan

F ρ camp µ camp
Komponen X
(Kg/Jam) (Kg/m3) (cp)
NaOH 3691.09 0.67 985.00 2.45
air 1801.41 0.33
Total 5492.50 1.00 985.00 2.45

1. Menentukan Laju Alir Cairan


Laju Alir massa Total, ṁ = 3.36 lbm/s
Densitas, ρ = 61.49 lbm/ft3
Laju Alir , Q Q = ṁ/ρ = (2,42
�𝑏𝑚/�)/(91,61 �𝑏𝑚/��)
= 0.055 ft3/s
= 24.55 gal/min (gpm)
= 0.002 m3/s 5.58 m3/h
Faktor Keamanan 20% Q x 1.2
Q = 0.002 m3/s
0.07 ft3/s
2. Menentukan diameter optimum pipa

Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)


Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)

Diameter optimum pipa = 0.053 m


2.067 In

sehingga dipilih Nominal Pipe Size (NPS)


NPS = 2 in (Geankoplis, App. A-5)
Schedule Numb. = 40
OD = 2.38 in
= 60.33 mm
= 0.06 m
Inside Diameter = 2.067 in
= 52.50 mm
= 0.053 m
= 0.172 ft
Luas penampang inside, A = 0.02 ft2
= 0.002 m2

Kecepatan linier dalam pipa, v �=𝑄/� = (0,001


𝑚3/�)/(0,001 𝑚2)
v = 0.859 m/s
2.817 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 2.448 cp


0.00245 Kg/m.s
0.002448 Pa.s
NRe = ρ�𝐷/µ
NRe = (1467,40 𝑘𝑔/(𝑚3 ) 𝑥 0,68
𝑚/� 𝑥 0,04 𝑚)/(0,01 𝑘𝑔/𝑚.�)

Nre = 18136.50

Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa


10 m
Asumsi panjang total, L
32.81 ft

Gate Vale full open = 0.13 ft (Geankoplis, tab.2.10-1)


1Gate Valve (GV) = 0.13 ft
Elbow 90 = 0.50 ft
2 Elbow 90 = 2.01 ft
Le = 2.14 ft
∆L = L + Le = 34.95 ft

Nre = 18136.5 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.00087619 (geankoplis, fig.2.10-3)

f = 0.007 (Geankoplis, fig.2.10-3)

5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 0.97 ft.lbf/lbm
6. Menghitung Head Pompa (H)

H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk


Turbulent Flow
Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

6,39
m

0.5 m
∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� + ∑F
= -Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2

mencari ∆P dengan ∆z = 6.39 - 0.5 = 5.89 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F
∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 56857.14 N/m2
8.25 psia
0.56 atm

z1 = 0.50 m
1.64 ft
z2 = 6.39 m (Tinggi mixer tank )
20.96 ft

∆P = 0.56 atm
8.25 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 27.27 ft
= 28.24 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 28.243 ft.lbf/lbm SI


(-Ws) = 84.42 J/Kg English
8. Menghitung Daya Pompa (Wp)
Efisiensi pompa, Ƞ = 18 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


BHP = 0.96 HP
0.72 kW
Efisiensi motor, Ƞe = 80 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,
Geankoplis)
Daya motor = 0.89 kW
1.20 HP
maka, dipilih motor listrik = 2 Hp
= 2 HP x 0.7457
= 1.491 kW

9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)
= 〖 3500 𝑥 11,88 〗 ^0,5/
〖 7900 〗 ^(4/3)
NPSH = 0.11 ft
= 0.03 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 985.00 kg/m3
v = 0.00245 kg/ms
z1 = -0.50 m
Pvp = 28.387 mmHg3.7846 Kpa
ƩF = 0.97 ft = 0.2969 m
9.8 x NPSHa = 91.22
NPSHa = 9.308 m
NPSHa > NPSHr

POMPA (P-202)
Kode : P-202 A/B
Jumlah : 2 buah
Fungsi : Sebagai alat transportasi dari tangki penyimpanan H2SO4
menuju mixer
Tipe : Pompa sentrifugal
Kapasitas : 5.58 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 2 HP
NPSH : 0.03 m
Ukuran Pipa : 2 in Sch Number 40
Bahan Pipa : Commercial Steel
Pompa 03 (P-203)
Fungsi : memompa h2so4 dari dissolver tank ke HE dan reaktor
Jenis : Centrifugal
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 unit cadangan

F ρ camp µ µ camp
Komponen X ρ
(Kg/Jam) (Kg/m3) (cp) (cp)
sulfat 3829.02 0.41 1827 752.35 19.7 8.12
air 5469.20 0.59 1023 601.73 0.75 0.44
Total 9298.23 1.00 1354.08 8.56

1. Menentukan Laju Alir Cairan


Laju Alir massa Total, ṁ = 5.69 lbm/s
Densitas, ρ = 84.54 lbm/ft3
Laju Alir , Q Q = ṁ/ρ = (2,42
�𝑏𝑚/�)/(91,61 �𝑏𝑚/��)
= 0.067 ft3/s
= 30.23 gal/min (gpm)
= 0.002 m3/s 6.87
Faktor Keamanan 20% Q x 1.2
Q = 0.002 m3/s
0.08 ft3/s
2. Menentukan diameter optimum pipa

Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)


Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)

Diameter optimum pipa = 0.06 m


2.366 In

sehingga dipilih Nominal Pipe Size (NPS)


NPS = 2 1/2 in (Geankoplis, App. A-5)
Schedule Numb. = 40
OD = 2.88 in
= 73.03 mm
= 0.073 m
Inside Diameter = 2.469 in
= 62.71 mm
= 0.063 m
= 0.206 ft
Luas penampang inside, A = 0.03 ft2
= 0.003 m2

Kecepatan linier dalam pipa, v �=𝑄/� = (0,001


𝑚3/�)/(0,001 𝑚2)
v = 0.741 m/s
2.431 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 8.562 cp


0.009 Kg/m.s
0.009 Pa.s
NRe = ρ�𝐷/µ
NRe = (1467,40 𝑘𝑔/(𝑚3 ) 𝑥 0,68
𝑚/� 𝑥 0,04 𝑚)/(0,01 𝑘𝑔/𝑚.�)

Nre = 7349.26

Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa


10 m
Asumsi panjang total, L
32.81 ft

Gate Vale full open = 0.15 ft (Geankoplis, tab.2.10-1)


1Gate Valve (GV) = 0.15 ft
Elbow 90 = 0.60 ft
2 Elbow 90 = 2.40 ft
Le = 2.55 ft
∆L = L + Le = 35.36 ft

Nre = 7349.26 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.000733535

f = 0.01 (Geankoplis, fig.2.10-3)

5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 0.84 ft.lbf/lbm
6. Menghitung Head Pompa (H)

H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk


Turbulent Flow

Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

3m

0.5 m ∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� + ∑F =


-Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2
mencari ∆P dengan ∆z = 3- 0.5 = 2.5 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 33175.90 N/m2
4.81 psia
0.33 atm

z1 = 0.50 m
1.64 ft
z2 = 3.00 m
9.84 ft

∆P = 0.33 atm
4.81 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 14.08 ft
14.91 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 14.913 ft.lbf/lbm SI


(-Ws) = 44.57 J/Kg English

8. Menghitung Daya Pompa (Wp)


Efisiensi pompa, Ƞ = 30 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)

BHP = 0.51 HP
0.38 kW
Efisiensi motor, Ƞe = 80 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor = 0.48 kW
0.64 HP
maka, dipilih motor listrik = 1 Hp
= 1 HP x 0.7457
= 0.746 kW
9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)
= 〖 3500 𝑥 11,88 〗 ^0,5/
〖 7900 〗 ^(4/3)
NPSH = 0.12 ft
= 0.04 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 1354.08 kg/m3
v = 0.008562 kg/ms
z1 = -0.50 m
Pvp = 13.112 mmHg 1.7481 Kpa
ƩF = 0.84 ft = 0.2546 m
9.8 x NPSHa = 66.14
NPSHa = 6.749 m
NPSHa > NPSHr
POMPA (P-203)
Kode : P-203 A/B
Jumlah : 2 buah
Fungsi : Sebagai alat transportasi dari tangki penyimpanan H2SO4
menuju dissolber
Tipe : Pompa sentrifugal
Kapasitas : 6.87 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 1 HP
NPSH : 0.04 m
Ukuran Pipa : 2 1/2 in Sch Number 40
Bahan Pipa : Commercial Steel
(Geankoplis, tab.2.10-1)
Pompa 04 (P-204)
Fungsi : memompa NaOH dari dissolver menuju ke HE dan Reaktor
Jenis : Centrifugal
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 cadangan

F ρ camp µ camp
Komponen X
(Kg/Jam) (Kg/m3) (cp)
NaOH 3691.09 0.08 985.00 2.45
air 42679.48 0.92
Total 46370.57 1.00 985.00 2.45

1. Menentukan Laju Alir Cairan


Laju Alir massa Total, ṁ = 28.40 lbm/s
Densitas, ρ = 61.49 lbm/ft3
Laju Alir , Q Q = ṁ/ρ = (2,42
�𝑏𝑚/�)/(91,61 �𝑏𝑚/��)
= 0.462 ft3/s
= 207.28 gal/min (gpm)
= 0.013 m3/s 47.1 m3/h
Faktor Keamanan 20% Q x 1.2
Q = 0.016 m3/s
0.55 ft3/s
2. Menentukan diameter optimum pipa

Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)


Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)

Diameter optimum pipa = 0.137 m


5.399 In

sehingga dipilih Nominal Pipe Size (NPS)


NPS = 6 in (Geankoplis, App. A-5)
Schedule Numb. = 80
OD = 6.63 in
= 168.30 mm
= 0.168 m
Inside Diameter = 5.761 in
= 146.30 mm
= 0.146 m
= 0.48 ft
Luas penampang inside, A = 0.18 ft2
= 0.017 m2

Kecepatan linier dalam pipa, v �=𝑄/� = (0,001


𝑚3/�)/(0,001 𝑚2)
v = 0.934 m/s
3.063 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 2.448 cp


0.00245 Kg/m.s
0.002448 Pa.s
NRe = ρ�𝐷/µ
NRe = (1467,40 𝑘𝑔/(𝑚3 ) 𝑥 0,68
𝑚/� 𝑥 0,04 𝑚)/(0,01 𝑘𝑔/𝑚.�)

Nre = 54954.22

Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa


10 m
Asumsi panjang total, L
32.81 ft
(Geankoplis, tab.2.10-1)
Gate Vale full open = 0.36 ft
1Gate Valve (GV) = 0.36 ft
Elbow 90 = 1.40 ft
2 Elbow 90 = 5.60 ft
Le = 5.96 ft
∆L = L + Le = 38.77 ft

Nre = 54954.2 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.000314422 (geankoplis, fig.2.10-3)

f = 0.005 (Geankoplis, fig.2.10-3)

5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 0.56 ft.lbf/lbm
6. Menghitung Head Pompa (H)

H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk


Turbulent Flow
Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

3m

0.5 m
∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� + ∑F
= -Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2

mencari ∆P dengan ∆z = 3- 0.5 = 2.5 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F
∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 24133.06 N/m2
3.50 psia
0.24 atm

z1 = 0.50 m
1.64 ft
z2 = 3.00 m
9.84 ft

∆P = 0.24 atm
3.50 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 17.49 ft
= 18.05 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 18.053 ft.lbf/lbm SI


(-Ws) = 53.96 J/Kg English
8. Menghitung Daya Pompa (Wp)
Efisiensi pompa, Ƞ = 45 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


BHP = 2.07 HP
1.54 kW
Efisiensi motor, Ƞe = 80 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,
Geankoplis)
Daya motor = 1.93 kW
2.59 HP
maka, dipilih motor listrik = 3 Hp
= 3 HP x 0.7457
= 2.237 kW

9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)
= 〖 3500 𝑥 11,88 〗 ^0,5/
〖 7900 〗 ^(4/3)
NPSH = 0.32 ft
= 0.10 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 985.00 kg/m3
v = 0.00245 kg/ms
z1 = -0.50 m
Pvp = 28.387 mmHg3.7846 Kpa
ƩF = 0.56 ft = 0.1704 m
9.8 x NPSHa = 92.46
NPSHa = 9.434 m
NPSHa > NPSHr

POMPA (P-204)
Kode : P-204 A/B
Jumlah : 2 buah
Fungsi : Sebagai alat transportasi dari tangki penyimpanan H2SO4
menuju dissolver
Tipe : Pompa sentrifugal
Kapasitas : 47.08 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 3 HP
NPSH : 0.098 m
Ukuran Pipa : 6 in Sch Number 40
Bahan Pipa : Commercial Steel
Pompa 05 (P-205)
Fungsi : memompa sodium silikat dari reaktor ke press filter
Jenis : Slurry Pump (positive displacement jenis gear)
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 cadangan
F ρ ρ camp µ µ camp
Komponen X
(Kg/Jam) (Kg/m3) (Kg/m3) (cp) (cp)
SiO2 709.87 0.01 2074.00 26.34116 0.96 0.01
Al2O3 74.27 0.00 3696.00 4.9112575 28.18 0.04
CaO 70.46 0.00 3030 3.8197293 1.903 0.00
MgO 82.84 0.00 3341 4.951809 2.703 0.00
K2O 365.64 0.01 2108.00 13.790234 1.08 0.01
Fe2O3 55.23 0.00 4921 4.8626804 27.96 0.03
NaOH 295.29 0.01 1145.00 6.0492502 0.06597 0.00
H2O 43444.38 0.78 988.00 767.9587 0.01459 0.01
Na2O.SiO2 10794.41 0.19 2251 434.73211 27.96 5.40
TOTAL 55892.39 1.00 1267.4169 5.50

1. Menentukan Laju Alir Cairan


Laju Alir massa Total, ṁ = 34.23 lbm/s
Densitas, ρ = 79.13 lbm/ft3
Laju Alir , Q Q = ṁ/ρ

= 0.433 ft3/s
= 194.17 gal/min (gpm)
= 0.012 m3/s 44.1 m3/h
Faktor Keamanan 20% Q x 1.2
Q = 0.015 m3/s
0.52 ft3/s
2. Menentukan diameter optimum pipa
Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)
Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)
Diameter optimum pipa = 0.138 m
5.417 In
sehingga dipilih Nominal Pipe Size (NPS)
NPS = 6 in (Geankoplis, App. A-5)
Schedule Numb. = 80
OD = 6.63 in
= 168.30 mm
= 0.168 m
Inside Diameter = 5.761 in
= 146.30 mm
= 0.146 m
= 0.48 ft
Luas penampang inside, A = 0.18 ft2
= 0.017 m2

Kecepatan linier dalam pipa, v �=𝑄/�

v = 0.874 m/s
2.869 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 5.50 cp


0.00550 Kg/m.s
0.0055022 Pa.s
NRe =
ρ�𝐷/µ
Nre = 49015.67
Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa

10 m
Asumsi panjang total, L
32.81 ft
Gate Vale full open = 0.36 ft (Geankoplis, tab.2.10-1)
1Gate Valve (GV) = 0.36 ft
Elbow 90 = 1.40 ft
2 Elbow 90 = 5.60 ft
Le = 5.96 ft
∆L = L + Le = 38.77 ft

Nre = 49015.7 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.000314422 (geankoplis, fig.2.10-3)

f = 0.0055 (Geankoplis, fig.2.10-3)


5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 0.51 ft.lbf/lbm

6. Menghitung Head Pompa (H)

H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk


Turbulent Flow
Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

2m

0.5 m
∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� + ∑F
= -Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2

mencari ∆P dengan ∆z = 2- 0.5 = 1.5 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F
∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 30988.11 N/m2
4.49 psia
0.31 atm

z1 = 0.50 m
1.64 ft
z2 = 2.00 m
6.56 ft

∆P = 0.31 atm
4.49 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 13.08 ft
= 13.59 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 13.593 ft.lbf/lbm SI


(-Ws) = 40.63 J/Kg English
8. Menghitung Daya Pompa (Wp)
Efisiensi pompa, Ƞ = 45 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


BHP = 1.88 HP
1.40 kW
Efisiensi motor, Ƞe = 82 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,
Geankoplis)
Daya motor = 1.71 kW
2.29 HP
maka, dipilih motor listrik = 3 Hp
= 3 HP x 0.7457
= 2.237 kW

9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)
= 〖 3500 𝑥 11,88 〗 ^0,5/
〖 7900 〗 ^(4/3)
NPSH = 0.31 ft
= 0.09 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 2108.00 kg/m3
v= 0.0055 kg/ms
z1 = -0.50 m
Pvp = 2.75491 mmHg0.3673 Kpa
ƩF = 0.51 ft = 0.1558 m
9.8 x NPSHa = 41.47
NPSHa = 4.231 m
NPSHa > NPSHr

POMPA (P-205)
Kode : P-205 A/B
Jumlah : 2 buah
Fungsi : memompa keluaran reaktor menuju press filter
Tipe : positive displacement pump
Kapasitas : 44.10 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 3 HP
NPSH : 0.094 m
Ukuran Pipa : 6 in Sch Number 40
Bahan Pipa : Commercial Steel
Pompa 06 (P-206)
Fungsi : memompa Na2O.SiO2 ke reaktor precipitated silica
Jenis : Centrifugal
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 cadangan

F ρ ρ camp µ µ
Komponen X
(Kg/Jam) (Kg/m3) (kg/m3) (cp) camp
Na2O.SiO2 9930.86 0.20 2251 446 27.9 5.52
air 39968.83 0.80 988.00 787 0.01459 0.01
NaOH 271.66 0.005 1145 6 0.06597 0.00
Total 50171.36 1.00 1238.85 5.53
1. Menentukan Laju Alir Cairan
Laju Alir massa Total, ṁ = 30.72 lbm/s
Densitas, ρ = 77.34 lbm/ft3
Laju Alir , Q Q = ṁ/ρ

= 0.397 ft3/s
= 178.31 gal/min (gpm)
= 0.011 m3/s 40.5 m3/h
Faktor Keamanan 20% Q x 1.2
Q = 0.013 m3/s
0.48 ft3/s
2. Menentukan diameter optimum pipa

Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)


Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)

Diameter optimum pipa = 0.132 m


5.198 In

sehingga dipilih Nominal Pipe Size (NPS)


NPS = 6 in (Geankoplis, App. A-5)
Schedule Numb. = 80
OD = 6.63 in
= 168.30 mm
= 0.168 m
Inside Diameter = 5.761 in
= 146.30 mm
= 0.146 m
= 0.48 ft
Luas penampang inside, A = 0.18 ft2
= 0.017 m2

Kecepatan linier dalam pipa, v �=𝑄/�

v = 0.803 m/s
2.635 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 5.53 cp


0.00553 Kg/m.s
0.0055345 Pa.s
NRe = ρ�𝐷/µ

Nre = 26299.63

Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa


10 m
Asumsi panjang total, L
32.81 ft
(Geankoplis, tab.2.10-1)
Gate Vale full open = 0.36 ft
1Gate Valve (GV) = 0.36 ft
Elbow 90 = 1.40 ft
2 Elbow 90 = 5.60 ft
Le = 5.96 ft
∆L = L + Le = 38.77 ft

Nre = 26299.6 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.000314422 (geankoplis, fig.2.10-3)

f = 0.007 (Geankoplis, fig.2.10-3)

5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 0.48 ft.lbf/lbm
6. Menghitung Head Pompa (H)

H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk


Turbulent Flow
Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

12m

0.5 m
∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� +
∑F = -Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2

mencari ∆P dengan ∆z = 12 - 0.5 = 11.5 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F
∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 139618.53 N/m2
20.25 psia
1.38 atm

z1 = 0.50 m
1.64 ft
z2 = 3.00 m
9.84 ft

∆P = 1.38 atm
20.25 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 15.3 ft
= 15.78 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 15.781 ft.lbf/lbm SI


(-Ws) = 47.17 J/Kg English
8. Menghitung Daya Pompa (Wp)
Efisiensi pompa, Ƞ = 50 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


BHP = 1.76 HP
1.31 kW
Efisiensi motor, Ƞe = 82 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,
Geankoplis)
Daya motor = 1.60 kW
2.15 HP
maka, dipilih motor listrik = 3 Hp
= 3 HP x 0.7457
= 2.237 kW

9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)

NPSH = 0.30 ft
= 0.09 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 1238.85 kg/m3
v = 0.00553 kg/ms
z1 = -0.50 m
Pvp = 3.267 mmHg0.4356 Kpa
ƩF = 0.48 ft = 0.1474 m
9.8 x NPSHa = 75.09
NPSHa = 7.663 m
NPSHa > NPSHr

POMPA (P-206)
Kode : P-206 A/B
Jumlah : 2 buah
Fungsi : memompa keluaran reaktor menuju press filter
Tipe : sentrifugal pump
Kapasitas : 40.50 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 3 HP
NPSH : 0.091 m
Ukuran Pipa : 6 in Sch Number 40
Bahan Pipa : Commercial Steel
Pompa 07 (P-207)
Fungsi : memompa precipitated silica dari reaktor ke rotary filter
Jenis : Slurry Pump (positive displacement jenis gear)
Bahan Konstruksi : commercial steel
Jumlah : 1 unit + 1 cadangan
F ρ ρ camp µ µ camp
Komponen X
(Kg/Jam) (Kg/m3) (Kg/m3) (cp) (cp)
SiO2 6736.11 0.11 2074.00 234.92165 0.30 0.03
Na2SO4 5456.21 0.09 2590 237.6271 82.85 7.60
H2SO4 61.81 0.00 18.39 0.0191137 4.149 0.00
H2O 46191.58 0.78 953.90 740.91911 0.01459 0.01
Na2O.SiO2 1023.87 0.02 2339 40.269865 27.96 0.48
TOTAL 59469.58 1.00 1253.7568 8.13

1. Menentukan Laju Alir Cairan


Laju Alir massa Total, ṁ = 36.42 lbm/s
Densitas, ρ = 78.27 lbm/ft3
Laju Alir , Q Q = ṁ/ρ

= 0.465 ft3/s
= 208.85 gal/min (gpm)
= 0.013 m3/s 47.4 m3/h
Faktor Keamanan 20% Q x 1.2
Q = 0.016 m3/s
0.56 ft3/s
2. Menentukan diameter optimum pipa
Asumsi: aliran turbulen (Re > 2100) and Di ≥ 0,0254 m (1 in)
Di,opt = 0,363 𝑄^0.45 ρ^0.13 (Peters, et all, p.501,
pers. 12-15)
Diameter optimum pipa = 0.142 m
5.59 In
sehingga dipilih Nominal Pipe Size (NPS)
NPS = 6 in (Geankoplis, App. A-5)
Schedule Numb. = 80
OD = 6.63 in
= 168.30 mm
= 0.168 m
Inside Diameter = 5.761 in
= 146.30 mm
= 0.146 m
= 0.48 ft
Luas penampang inside, A = 0.18 ft2
= 0.017 m2

Kecepatan linier dalam pipa, v �=𝑄/�

v = 0.941 m/s
3.086 ft/s

3. Menghitung Bilangan Reynold (NRe)

Viskositas fluida, µ = 8.13 cp


0.00813 Kg/m.s
0.0081325 Pa.s
NRe =
ρ�𝐷/µ
Nre = 21214.89
Karena Nre > 2100 maka aliran turbulen

4. Menghitung panjang Equivalen dan panjang pipa

10 m
Asumsi panjang total, L
32.81 ft
Gate Vale full open = 0.36 ft (Geankoplis, tab.2.10-1)
1Gate Valve (GV) = 0.36 ft
Elbow 90 = 1.40 ft
2 Elbow 90 = 5.60 ft
Le = 5.96 ft
∆L = L + Le = 38.77 ft

Nre = 21214.9 dengan bahan Commercial Steel, Ɛ = 0.000046


Ɛ/D = 0.000314422 (geankoplis, fig.2.10-3)

f = 0.007 (Geankoplis, fig.2.10-3)

5. Menghitung Total friction Loss (∑F)

Ke = (1 - A1/A2)^2
Ke = 0 = 0 (tidak ada perubahan ukuran pipa)
Kc = 0.55*(1 - A1/A2)
= 0.55
Kf = 2 Elbow 90 + 1 Gate valve
Elbow 90, Kf = 0.75
Gate Valve, Kf = 0.17 (Tab. 2.10-1 Geankoplis)
Kf = (2 x 0,75) + (1 x 0.17 )
Kf = 1.67
∑F = (4 f □(64&∆𝐿/𝐷) + Kc + Ke + Kf) �2/(2 𝑔�)

ƩF = 0.66 ft.lbf/lbm

6. Menghitung Head Pompa (H)


H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F (McCabe, Eq. 8.2) 𝛼=1 untuk
Turbulent Flow
Mencari ∆P, diasumsikan sistem perpipaan seperti tampak pada gambar berikut

5m

0.5 m
∆𝑃/"ρ" + 𝑔/𝑔� ∆z + ("∆" �2)/2𝛼𝑔� + ∑F
= -Ws
v1 = v2 = 0 krn ukuran pipa sama
Asumsi , -Ws = 0
pers. Bernoulli menjadi
∆P = (𝑔 )/𝑔� . ∆z . ρ + ∑F
dimana g = 9.8 m/s2 ; gc = 1 kg.m/Ns2

mencari ∆P dengan ∆z = 5- 0.5 = 4.5 m

∆P = 𝑔/𝑔� ∆z ρ + ∑F

∆P = 55291.34 N/m2
8.02 psia
0.55 atm

z1 = 0.50 m
1.64 ft
z2 = 5.00 m
16.40 ft

∆P = 0.55 atm
8.02 psia
H = ∆𝑃/𝜌 + (𝑔 ∆�)/𝑔� + (𝛼 ṽ2)/(2 𝑔�) + ∑F g = 32.174 ft/s2 ; gc = 32.174
lbm.ft/s2
g= 32.174 ft/s2
gc = 32.174 lbm.ft/s2
H = 24.24 ft
= 24.9 ft

7. Menghitung Kerja Pompa (-Ws)

-Ws = Hg (SI)
-Ws = H 𝑔/𝑔� (English) .........(Eq. 3.3-4 ,
Geankoplis)
g = 32.174 ft/s2
gc = 32.174 lbm.ft/s2

(-Ws) = 24.904 ft.lbf/lbm SI


(-Ws) = 74.44 J/Kg English
8. Menghitung Daya Pompa (Wp)
Efisiensi pompa, Ƞ = 45 % (Peters & Timmerhause, Fig. 14-37)

Brake HP = (−𝑊� ṁ)/(Ƞ 550) (Eq. 3.3-2, Geankoplis)


BHP = 3.66 HP
2.73 kW
Efisiensi motor, Ƞe = 84 % (Peters & Timmerhause, Fig. 14-38)

Daya motor (kW) = (𝐵𝑟�𝑘𝑒 𝑘𝑊)/(Ƞ 𝑒) (Eq. 3.3-5,


Geankoplis)
Daya motor = 3.25 kW
4.36 HP
maka, dipilih motor listrik = 5 Hp
= 5 HP x 0.7457
= 3.729 kW

9. Menghitung NPSH
NPSHr
Impeler speed, N = 3500 rpm (Coulson Fig. 5.6)
Spesific speed, S = 7900 (Wallas, 2012)
NPSH = 〖� � �〗 ^0,5/𝑆^(4/3)

NPSH = 0.32 ft
= 0.10 m

g= 9.8 m/s2 (geankoplish, eq. 3.3-6)


P1 = 101325 Pa
= 1253.76 kg/m3
v = 0.00813 kg/ms
z1 = -0.50 m
Pvp = 4.11 mmHg 0.548 Kpa
ƩF = 0.66 ft = 0.2021 m
9.8 x NPSHa = 73.5
NPSHa = 7.5 m
NPSHa > NPSHr

POMPA (P-107)
Kode : P-107 A/B
Jumlah : 2 buah
Fungsi : memompa keluaran reaktor menuju rotary filter
Tipe : positive displacement pump
Kapasitas : 47.43 m3/jam
P suction : 101.33 kPa
P discharge : 101.33 kPa
Power Pompa : 5 HP
NPSH : 0.098 m
Ukuran Pipa : 6 in Sch Number 40
Bahan Pipa : Commercial Steel
Neraca Massa Furnace Neraca Energi Rotary Kiln
Input (kg/jam) Output (kg/jam) Input (kj/jam)
Komponen Komponen
1 3 2 4 1
C 19,856.80 - - - C 69,898.30
H2 2,728.01 - - - H2 19,723.40
N2 73.45 - - - N2 2,829.88
SO2 320.02 - - - SO2 1,172.14
O2 14,505.69 - - - O2 435,622.15
Abu Sekam 9,521.82 - 9,521.82 - Abu Sekam 12,145,517.97
H2O 5,456.03 - - - H2O 46,712.01
Udara - 260,031.67 - - Udara -
Flue Gas - - - 302,971.67 Flue Gas -
TOTAL 312,493.49 312,493.49 Q SISTEM 627,787,205.61
Q REAKSI -504,314,287.33
Dissolver NaOH TOTAL 137,070,713.03
Input (kg/jam) Output (kg/jam)
Komponen
5 7 6 Neraca Energi HE-NaOH
NaOH 3,691.09 - 3,691.09 Input (Kj/jam)
Komponen
H2O 1,801.41 40,878.07 42,679.48 Panas
TOTAL 46,370.57 46,370.57 Steam H2O 56,733,986.64
H2O -
Dissolver Sulfat NaOH -
Input (kg/jam) Output (kg/jam) TOTAL 57,668,238.2
Komponen
11 13 12
H2SO4 3,829.02 - 3,829.02 Neraca Energi HE-H2SO4
H2O 469.14 5,000.06 5,469.20 Input (Kj/jam)
Komponen
TOTAL 9,298.23 9,298.23 Panas
Steam H2O 31,915,951.29
Reaktor H2O -
Input (kg/jam) Output (kg/jam) H2SO4 -
Komponen
Komponen
2 6 8 TOTAL 32,057,918.7
SiO2 8,873.38 - 709.87
Al2O3 74.27 - 74.27 Neraca Energi COOLER
CaO 70.46 - 70.46 Input (Kj/jam)
Komponen
MgO 82.84 - 82.84 Panas
K2O 365.64 - 365.64 NaOH 80,880.48
Fe2O3 55.23 - 55.23 H2O 25,095,486.51
NaOH - 3,691.09 295.29 Na2O.SiO2 3,650,882.78
H2O - 42,679.48 43,444.38 TOTAL 40,464,103.2
Na2O.SiO2 - - 10,794.41
TOTAL 55,892.39 55,892.39

Filter Press Neraca Energi Reaktor 1


Input (kg/jam) Output (kg/jam) Input (kj/jam)
Komponen Komponen
8 9 10 2
SiO2 709.87 - 709.87 SiO2 1,009,249.13
Al2O3 74.27 - 74.27 Al2O3 9,055.69
CaO 70.46 - 70.46 CaO 6,171.30
MgO 82.84 - 82.84 MgO 11,350.85
K2O 365.64 - 365.64 K2O 438,045.61
Fe2O3 55.23 - 55.23 Fe2O3 10,538.33
NaOH 295.29 271.66 23.62 NaOH -
H2O 43,444.38 39,968.83 3,475.55 H2O -
Na2O.SiO2 10,794.41 9,930.86 863.55 Na2O.SiO2 -
TOTAL 55,892.39 55,892.39 Q SISTEM 65,445,218.42
Q REAKSI -63,718,871.24
Reaktor 2 TOTAL 28,963,045.02
Input (kg/jam) Output (kg/jam)
Komponen
9 12 14 reaktor 2
NaOH 271.66 - - Input (kg/jam)
Komponen
Komponen
H2O 39,968.83 5,469.20 46,191.58 9
Na2O.SiO2 9,930.86 - 1,023.87 NaOH 40,080.08
H2SO4 - 3,829.02 61.81 H2O 12,991,208.72
SiO2 - - 6,736.11 Na2O.SiO2 4,855,313.51
Na2SO4 - - 5,456.21 H2SO4
TOTAL 59,469.58 59,469.58 SiO2
Na2SO4 -
Rotary Filter Q SISTEM 69,087,965.07
Input (kg/jam) Output (kg/jam) Q REAKSI -80,064,455.35
Komponen
14 16 15 17 TOTAL 7,294,974.26
H2O 46,191.58 255.78 923.83 45,523.53
Na2O.SiO2 1,023.87 - - 1,023.87 rvf
H2SO4 61.81 - - 61.81 Input (kj/jam)
Komponen
SiO2 6,736.11 - 6,736.11 - 14
Na2SO4 5,456.29 - - 5,456.29 Na2O.3,2SiO2 460,536.20
TOTAL 59,725.44 59,725.44 H2O 5,879,987.43
H2SO4 6,175.98
Rotary Dryer (asumsi kandungan air maks pada produk akhir adalah 3%) SiO2 354,368.60
Input (kg/jam) Output (kg/jam) Na2SO4 591,612.18
Komponen
15 18 19 Total 7299138.07694
H2O 923.83 208.33 715.50
SiO2 6,736.11 6,736.11 - rd
TOTAL 7,659.94 7,659.94 Input (kj/jam)
Komponen
15
Ball Mill Entalpi udara 14458502.7430286
Input (kg/jam) Output (kg/jam) entalpi bahan 143133.419580117
Komponen
18 22 20 Q loss -3449661.72772438
H2O 208.33 6.249996 214.58 Jumlah 11151974.4348844
SiO2 6,736.11 202.083204 6,938.19
TOTAL 7,152.77 7,152.77
Screener
Input (kg/jam) Output (kg/jam)
Komponen
20 21 22
H2O 214.58 208.33 6.25
SiO2 6,938.19 6,736.11 202.08
TOTAL 7,152.77 7,152.77
Input (kj/jam) Output (kj/jam)
3 2 4
- - -
- - -
- - -
- - -
- - -
- 7,114,988.97 -
- - -
876,318.89 - -
- - 129,955,724.06
627,787,205.61 - -
-504,314,287.33 - -
137,070,713.03 137,070,713.03

Panas Dingin
Input (Kj/jam) Output (Kj/jam) C K C K
Dingin Panas Dingin T input 350.00 623.15 30.00 303.15
- 31,915,951.29 - Toutput 211.25 484.40 162 435.15
894,057.79 - 24,653,642.02
40,193.79 - 1,098,644.90
57,668,238.2 57,668,238.2

Input (Kj/jam) Output (Kj/jam) Panas Dingin


Dingin Panas Dingin C K C K
- 30,979,144.34 - T input 211.25 484.40 30.00 303.15
114,569.93 - 696,205.94 Toutput 205.90 479.05 92.8 365.95
27,397.44 - 382,568.37
32,057,918.7 32,057,918.7

Input (Kj/jam) Output (Kj/jam) Panas Dingin


Dingin Panas Dingin C K C K
- 40,080.08 - T input 162.00 435.15 30.00 303.15
11,636,853.41 12,295,002.77 23,273,706.82 Toutput 92.80 365.95 35.01 308.1568
- 4,855,313.51 -
40,464,103.2 40,464,103.2

Input (kj/jam) Output (kj/jam)


6 8
- 80,739.93
- 9,055.69
- 6,171.30
- 11,350.85
- 10,928.02
- 10,538.33
1,098,644.90 87,891.59
24,653,642.02 25,095,486.51
- 3,650,882.78
65,445,218.42 - -
-63,718,871.24 - -
28,963,045.02 28,963,045.02

Input (kg/jam) Output (kg/jam)


12 14
- -
2,293.87 5,879,987.43
- 460,536.20
382,568.37 6,175.98
- 354,368.60
- 591,612.18
69,087,965.07
-80,064,455.35
7,294,974.26 7,292,680.40

Input (kj/jam) Output (kj/jam)


16 17 15
256265.912668
6457.68 6645808.03691 134026.122938
3768.65031594
9107.296642121
250162.057554
7299138.07703109

Input (kj/jam) Output (kj/jam)


15 18
14458502.7430286 10,883,358.66
143133.419580117 268615.773393664
-3449661.72772438
11151974.4348844 11,151,974.43
2. Pompa (P-05)
Fungsi : Untuk mengalirkan slurry dari reaktor ke filter press
Tipe : Pompa rotary (gear pump)
Jenis pipa : commercial stell
data spesifik grafity dari perryb 3th hal. 55
Komposisi bahan 162 c HYSYS
Komposisi Persentasi F kg/jam) ρ (kg/m3) ρ campuran (kg/m3) µ (cP) ln µ campuran (cP)
#REF! #REF! #REF! 2251 #REF! 53.69 #REF!
#REF! #REF! #REF! 0.5074 #REF! 0.01459 #REF!
#REF! #REF! #REF! 2074 #REF! 0.9564 #REF!
#REF! #REF! #REF! 1145 #REF! 0.06597 #REF!
#REF! #REF! #REF! 3696 #REF! 28.18 #REF!
#REF! #REF! #REF! 3030 #REF! 1.903 #REF!
#REF! #REF! #REF! 3341 #REF! 2.703 #REF!
#REF! #REF! #REF! 2108 #REF! 1.077 #REF!
#REF! #REF! #REF! 4921 #REF! 27.96 #REF!
Jumlah #REF! #REF! 22566.51 116.54996 #REF!

Kondisi operasi :
Temperatur = 162 o
C
Laju alir masuk = #REF! kg/jam #REF! lbm/s
Densitas, ρ = 22,566.5074 kg/m3 1408.8218 lbm/ft3
Viskositas, µ = exp=(ln µ campuran)
#REF! cp #REF! lbm/ft . S (Reid.1977)
Tekanan masuk = 1 atm 14.695949 psi 2116.2166272
Tekanan kelua = 1 atm 14.695949 psi 2116.2166272
Laju alir volum = F/ρ #REF! ft /s
3

Perhitungan :
a) Perencanaan pompa
Diameter pipa ekonomis, De
De = 3,9 x Q0,45 x ρ=0,13 #REF! in #REF! ft (Peters et.al., 2004)
Dari Appendix A.5-1 Geankoplis, hal 907 dipilih :
Jenis pipa : Commercial stell, sch 40
NPS = 2 in 0.1666666 ft
Diameter dala = 2.067 in 0.1722499 ft
Diameter luar = 2.375 in 0.1979166 ft
Luas penampan = 0.0233 ft2

b) Pengecekan bilangan reynold, Nre


Kecepatan rata - rata fluida, V
V = Q/A = #REF! ft/s
NRe = (ρ . = #REF! (Turbulen)(Geankoplis.1993, halaman 86)
ID . V)/µ (Fig. 2.10-3 Geankoplis.1993 halaman 88)
Untuk commercial= stell, Ɛ 0.000046 m 0.0001509 ft
kekasaran relatif ,=Ɛ/D 0.0008761608 ft
Untuk aliran turbulen, f
f = 0,079/ = 0.0048
(NRe 0,25)

c) Menentukan panjang ekivalen total pipa, ƩL


Kelengkapan pipa :
1) Panjang pip = 26.24672 ft 8 m
2) 1 buah gate 13 (Appendix C-2a, Foust, 1980)
L2 = 1 x 13 x I = 2.2392491043 ft 0.6825231 m
3) 2 buah standard
30 elbow 90oC, (L/D) (Appendix C-2a, Foust, 1980)
L3 = 2 x 30 x I = 10.334995866 ft 3.1501066 m
4) 1 buah sharp edge entrance, K = 0,5 ;(Appendix C-2a, Foust, 1980)
L4 = 0,5 x 22 x = 1.8947492421 ft 0.5775196 m
5) 1 buah sharp edge exit, K = 1,0 ; (L/D(Appendix C-2a, Foust, 1980)
L5 = 1,0 x 55 x = 9.4737462105 ft 2.8875978 m
Panjang pipa t = 50.1894604229 ft 15.297747 m

d) Menentukan Friksi, ƩF (Geankoplis.1993 halaman 86, persamaan 2.10-6)


ƩF = (4 x f x V2 x= #REF! ft . Lbf / lbm
ƩL)/(2 x gc x
ID)
e) Kerja yang dibutuhkan, -Wf
-Wf = ∆Z g/gc+∆V2/(2.gc) (Geankoplis.1993 halaman 95, persamaan 2.10-20)
+ ∆P/ρ+ ƩF
∆Z diperkiraka = 10 ft
Static head, ∆z = 10 ft . Lbf/lbm
g/gc
= 2/
Velocity head ,∆V 0
(
2. gc)
=
Pressure head ,∆P/ρ 0

- Wf = #REF! ft lbf/lbm
f) Daya pompa, Ws
Effisiensi po = 80%
(Geankoplis.1993 halaman 65, persamaan 2.7-30)
Ws = #REF! HP

g) menghitung BHP teori


BHP = Ws x G
= #REF! x #REF!
= #REF! hp

h) menghitung BHP aktual 1ft3/s 448.83 gal/s


Qf = #REF! ft3/s
#REF! gal/s
Diperoleh efisiensi pom 15% (Fig.14-37 p.520, Timmerhause)
Maka, BPH aktual :
BPH = #REF! hp
15%
= #REF! hp
Diambil 0.0083 hp

i) Menghitung Tenaga Motor Pompa


Pada nilai BHP 0.0083 hp diperoleh efisiensi motor yaitu 80%
(Fig.14-38 p.520, Timmerhause)
BHP motor = BHP aktual
h
= 0.0083
80%
= 0.010375 hp
Diambil 0.05 hp

j) Menghitung NPSH ( Net Positive Suction Head ) Pompa


NPSH Availabl: Abs Press ± hs -hfs- Vap Press
Abs press : Tekanan absolut fluida yang akan dipompa
Vap Press : Tekanan uap cairan ( m)
Hs : Static suction head (m)
hfs : Pressure drop in suction line (m)
(Tabel 7-1, p.163, Yaws)
Absolute Pres 1 atm = 1.013 bar
= 10 m
Vap Pressure

1 m3/s = 35.314667 ft3/s

Spesifikasi Alat Pompa 5


Kode : P-05 A/B
Jumlah : 1 Buah
Fungsi : Sebagai alat transportasi dari tangki reaktor 1
menuju filter press
Tipe : Pompa gear pump
Kapasitas : #REF! ft^3/s #REF! m3/s
P suction : 1 atm
P discharge : 1 atm
Power Pomp: 0.05 HP

Ukuran Pipa : 3 in Sch Number 40


Bahan Pipa : Commercial Steel
ln µ campuran (cP)

Data Sesifik grafity Perry 3th hal. 55

kg/jam lbm/jam lbm/s


1 2.20462 0.000612
lb/ft3 kg/m3
1 16.018
cp lbm/ft detik
lbf/ft2 1 0.000672
Konversi

lbf/ft3 atm psi


1 14.69595
psi lbf/ft2
1 144
in ft
1 0.083333
(Peters et.al., 2004) m ft
1 3.28084

16.4042
0.000
(Tabel 7-1, p.163, Yaws)
80%

( Branan, p. 107 )
(m)
(Tabel 7-1, p.163, Yaws)
Screw Conveyor (SC-203)
Fungsi : Alat transportasi precipitated silica ke bucket elevator

Jumlah = 1 unit
Laju alir = 7,659.94 kg/jam
= 7.6599384 ton/jam
Penentuan material yang digunakan
Perry 7th, hal 21-6 Tabel 21-4 untuk class Sand, Silica - B18
Size = 100 mesh - 1/8 in
Flowability = very free flowing - angle of repose up to 30o
Average bulk density = 90-100 lb/ft3
Dilihat dari kapasitas 14,7 ton dapat dilihat spesifikasi screw conveyor Perry 7th,
hal 21-8 Tabel 21-6
Jumlah = 1 unit
Diameter pipa = 2.5 in
Diameter shaft = 2 in
Diamter flights = 10 in
Ukuran lumps = 0.75
Kecepatan = 80 rpm
Power = 9.6 hp
RESUME
Kode SC-203
Fungsi Alat transportasi precipitated silica ke bucket elevator
Material Carbon Steel SA-266 grade: 3
Jumlah 1 buah
Flowability Very Free Flowing
Kecepatan 80 rpm
Power 9.6 hp
Screw Conveyor (SC-101)

Fungsi : Mengangkut sekam padi dari gudang ke rotary kiln

Jumlah = 1 unit
Laju alir = 52,461.82 kg/jam
= 52.461819 ton/jam
Penentuan material yang digunakan
Perry 7th, hal 21-6 Tabel 21-4 untuk class wood Chips
Size = fibrous, stingy, or the like
Flowability = Sluggish-angle of repose 45o and up
Average bulk density = 15 lb/ft3
Dilihat dari kapasitas 52 ton dapat dilihat spesifikasi screw conveyor Perry 7th,
hal 21-8 Tabel 21-6

Jumlah = 1 unit
Diameter pipa = 3.5 in
Diameter shaft = 3 in
Diamter flights = 16 in
Ukuran lumps = 1.5
Kecepatan = 50 rpm
Power' = 13 hp

RESUME
Kode SC-101
Fungsi Mengangkut sekam padi dari gudang ke rotary kiln

Material Carbon Steel SA-266 grade: 3


Jumlah 1 buah
Flowability Sluggish
Kecepatan 50 rpm
Power 13 hp
Screw Conveyor (SC-202)

Fungsi : mengangkut Abu sekam padi ke reaktor sodium silikat

Jumlah = 1 unit
Laju alir = 9,521.82 kg/jam
= 9.5218201 ton/jam
Penentuan material yang digunakan
Perry 7th, hal 21-6 Tabel 21-4 untuk class Fly Ash
Size = Very fine, < 100 mesh
Flowability = very free flowing, angle of repose up to 30o
Average bulk density = 35-45 lb/ft3
Dilihat dari kapasitas 9,5 ton dapat dilihat spesifikasi screw conveyor Perry 7th,
hal 21-8 Tabel 21-6

Jumlah = 1 unit
Diameter pipa = 2.5 in
Diameter shaft = 2 in
Diamter flights = 10 in
Ukuran lumps = 0.75
Kecepatan = 55 rpm
Power' = 6.6 hp

RESUME
Kode SC-202
Fungsi Alat transportasi bahan dari rotary kiln
ke reaktor sodium silikat
Material Carbon Steel SA-266 grade: 3
Jumlah 1 buah
Flowability very free flowing
Kecepatan 55 rpm
Power 7 hp
Screw Conveyor (SC-304)

Fungsi : Mengangkut produk menuju silo

Jumlah = 1 unit
Laju alir = 6,944.44 kg/4 jam
= 6.94444 ton/4 jam
Penentuan material yang digunakan
Perry 7th, hal 21-6 Tabel 21-4 untuk class Sand, Silica
Size = 100 mesh - mm
Flowability = very free flowing - angle of repose up to 30o
Average bulk density = 90-100 lb/ft3
Dilihat dari kapasitas 7 ton dapat dilihat spesifikasi screw conveyor Perry 7th,
hal 21-8 Tabel 21-6
Jumlah = 1 unit
Diameter pipa = 2.5 in
Diameter shaft = 2 in
Diamter flights = 9 in
Ukuran lumps = 0.75
Kecepatan = 40 rpm
Power' = 5 hp

RESUME
Kode SC-304
Fungsi Alat transportasi bahan dari screener
ke silo
Material Carbon Steel SA-266 grade: 3
Jumlah 1 buah
Flowability very free flowing
Kecepatan 40 rpm
Power 5 hp
Bucket Elevator (BE-201)

Spesifikasi alat
Fungsi : Mengangkut Precipitated Silica dari Rotary Dryer
ke Hopper sebelum Ball Mill
Kode : BE - 201
Tipe : spaced bucket centrifugal bucket
Kapasitas : 6,944.44 kg/jam 6.94444 ton/jam
Kondisi Operasi :
Temperature (T) : 30°C
Tekanan (P) : 1 atm = 14.7 psi

Faktor Kelonggaran : 20%


Kapasitas : 8333.328 kg/jam 8.3333 ton/jam
Spesifikasi Bucket Elevator dengan kapasitas ≤ 14 ton/jam
Tinggi Elevator : 25 ft = 7.62 m
Ukuran Bucket : 6 x 4 x 4 1/4
Jarak antar Bucket : 12 in = 0,305 m
Kecepatan Bucket : 225 ft/mnt = 68,6 m/mnt = 1,143 m/s
Kecepatan Putaran : 43 rpm
Lebar Belt : 7 in = 0,1778 m = 17,78 cm
Power : 1 hp
Ukuran Head : 19,375
Ukuran Tail : 16,875
Ukuran Lumps : 0,75 in
Jumlah : 1 unit
Sumber : Tabel 21.8 Perry ed 7th, hal 21-15

Untuk perhitungan daya (P) dari Peters, et.al.,2004


Daya untuk Bucket Elevator I
Daya yang dibutuhkan
P = 0,07 x m^0,63 x ΔZ
Dimana :
P = daya (kW)
m = laju alir massa (kg/s)
∆Z = tinggi elevator (m)
m = 6,944.44 kg/jam 1.9290 kg/s
∆Z = 25 ft = 7.62 m
maka :
P = 0.07 x 1,5127 x 7.62
= 0.8069 KW 1 HP

Bucket Elevator (BE-202)

Spesifikasi alat
Fungsi : Mengangkut Precipitated Silica dari ball mill menuju
vibrating screener
Kode : BE - 202
Tipe : spaced bucket centrifugal bucket
Kapasitas : 6,944.44 kg/jam
Kondisi Operasi :
Temperature (T) : 273 K
Tekanan (P) : 101.325 kPa

Faktor Kelonggaran : 20%


Kapasitas : 8333.328 kg/jam
Spesifikasi Bucket Elevator dengan kapasitas ≤ 14 ton/jam
Tinggi Elevator : 25 ft = 7.62 m
Ukuran Bucket : 6 x 4 x 4 1/2 mm
Jarak antar Bucket : 12 in = 0,305 m
Kecepatan Bucket : 225 ft/mnt = 68,6 m/mnt = 1,143 m/s
Kecepatan Putaran : 43 rpm
Lebar Belt : 7 in = 0,1778 m = 17,78 cm
Power : 1 hp
Ukuran Head : 19,375
Ukuran Tail : 16,875
Ukuran Lumps : 0,75 in
Jumlah : 1 unit
Sumber : Tabel 21.8 Perry ed 7th, hal 21-15

Untuk perhitungan daya (P) dari Peters, et.al.,2004


Daya untuk Bucket Elevator 2
Daya yang dibutuhkan
P = 0,07 x m^0,63 x ΔZ
Dimana :
P = daya (kW)
m = laju alir massa (kg/s)
∆Z = tinggi elevator (m)
m = 6,944.44 kg/jam 1.9290 kg/s
∆Z = 25 ft = 7.62 m
maka :
P = 0,07 x 1,5127 x 7,62
= 0.8069 KW
= 1 HP
Rotary Kiln (RK-201)
Fungsi : Membakar sekam padi
Jenis : Rotary Kiln
Bahan : High Steel Alloy 316

Jumlah Bahan Umpan : 52,461.82 Kg solid/Jam = 115657 lb/jam


r solid : 384 lb/ft3
Tekanan operasi : 1 atm = 0.101 N/mm2
Suhu udara masuk : 30 oC 86 F
Suhu udara keluar : 800 oC 1472 F
Suhu bahan masuk : 30 oC 86 F
Suhu bahan keluar : 162 oC 323.6 F

1. Menentukan Ukuran Rotary Kiln


Berat material dalam kiln (w) = 115657 lbs
Densitas bahan = 384 lb/ft3
Volume bahan dalam kiln = berat bahan
densitas bahan
= 301.2 ft3 8.52370398 M3
Volume padatan dalam kiln adalah 15% dari total volume kiln (perry7ed, 12-54)
maka, volume kiln adalah : 2007.9396889 ft3 56.8247 M3
Vs = 1/4 𝜋 𝐷_(𝑖 )
^2 𝐻

ratio L/D yang dianjurkan yaitu 4-10 (perry's 7ed, halaman 12-54), ratio yang di
pilih yaitu, L / = 4
Vs = 𝜋 𝐷^3
D = 8.6153648102 Ft = 2.6259632 m

Length of Rotary Kiln


Panjang rotary kiln = 34.46 ft = 10.503853 m

3. Kecepatan Putaran Rotary Kiln


Shell pheriperal speed untuk rotary kiln adalah 60-75 ft/min (perry's 7ed, hal. 12-54)
dipilih shell pheriperal speed yaitu 75 ft/min
dengan besaran rotasi per menit (rpm)

vr = sheel speed = 60 = 6.9643017 rpm


D 8.62

6. Tebal Shell
Material yang digunakan untuk rotary kiln adalah high alloy steel 316 dengan
alasan pemilihan karena tahan terhadap temperatur operasi kiln yaitu 800oC
(Brownell and young, page 253)

Las dipakai double welded butt joint, dengan E = 0.8


Allowable Stress : 18700 psi 128.843 N/mm2
Faktor Korosi = 0.125
Tekanan Desain = 1,5 x Tekanan Operasi = 0.1515 N/mm2
t= pxD
2xfxe+p
dimana : t= 1.815 mm
t = tebal shell (mm)
p = tekanan desain (N/mm2)
D = Diameter kiln (mm)
F = Allowable Stress (N/mm2)
E= 0.8

maka, diameter luar kiln adalah Diameter dalam + Ketebalan Shell :


Diameter luar = D2 = 2628 mm
= 2.628 m = 8.62132 ft
7. Kebutuhan Daya Rotary Kiln

power = r x (4,75 x d x w + 0,1925 x D x W + 0,33 x W)


100000
(perry 7ed, eq. 12-60)

dimana : r = rpm of rotary kiln ( rpm )


d= shell diameter (ft)
W= Berat total kiln(lb)
w= Berat material (lb)
D= diameter cincin kiln (D+2, ft)

menghitung berat total Kiln


Berat shell dryer = volume shell dryer x densitas bahan
densitas high alloy stee 490.75 lbs/ft3 , maka :
Berat shell dryer = 985396.40233 lbs
Berat material dalam dryer = 115657 lb/jam

Berat total dryer = Berat shell dryer + berat material dalam dryer
W = 1101054 lbs

Menghitung Shell Diameter


Shell diameter = Diameter inner dryer + 2 10.62 ft

maka, daya yang dibutuhkan oleh dryer = 558.62 BHP


= 416.73 KW
8. Daya yang dipakai oleh Exhaust Fan
Temperatur bahan kelua= 162 C 435 K
Laju alir bahan = 52,461.82 kg/jam
Temperatur udara pendingin = 30 C 303 K
volume udara yang dibutuhkan untuk mendinginkan = 28080.709 m3/jam
Fan Operating Pressure = 14.658804 psi
Daya yang dibutuhkan untuk menggerakkan poros motor :
HP = 1.57x10-4 x Q x P (perry's 7ed eq.10-88)
HP = 64.6 hp
Efisiensi blower 40% - 70%(Perry, hal 10-46)
Dipakai 70%
HP = 92.323 hp 68.872689886 KW
RESUME (RK-201)
Nama Rotary Kiln
Kode RK-201
Fungsi Membakar sekam padi menjadi abu pada suhu 800oC
Tipe Indirect Fired Heat
Volume Rotary Kiln 56.82 m3
Diameter IN 2.63 m
Panjang Shell 10.50 m
Kecepatan Putaran 6.96 rpm
Tebal Shell 1.82 mm
Berat total 1101053.73 lbs
Diameter OUT 3 m
Daya Rotary Dryer 558 BHP
Daya Blower 423 HP
Daya Exhaust Fan 92 HP
Blower (BL-101)
Fungsi : mengalirkan udara untuk pembakaran pada combustor
Jenis : blower sentrifugal
Bahan :Carbon Steel

Menghitung Daya yang dipakai oleh Blower


Laju alir udara = 260,032 kg/jam
densitas = 1.18719 kg/m3
volume udara = 219032 m3/jam
= 3650.53 m3/menit
= 128915 ft3/menit
Fan Operating Pressure = 14.6588 psi
Daya yang dibutuhkan untuk menggerakkan poros motor :
HP = 1.57x10-4 x Q x (perry's
P 7ed eq.10-88)
HP = 296.6887 hp
Efisiensi blower 40% - 70% (Perry, hal 10-46)
Dipakai 70% HP = 424 hp 316.1853421 KW

12-54), ratio yang di

ry's 7ed, hal. 12-54)


Rotary Dryer (RD-201)
Fungsi : Mengurangi kandungan H2O pada silika
Jenis : Rotary Dryer
Bahan : Carbon Steel SA 515

Jumlah Bahan Umpan : 7,659.94 Kg solid/Jam = 16887 lb/jam


Padatan dalam Umpan : 6,736.11 kg/jam = 14850 lb/jam
Air dalam Umpan = 923.83 kg/jam = 2036.6756 lb/jam
Air dalam Produk = 208.33 kg/jam = 459.29137 lb/jam
Air hilang : 715 kg/h = 1577 lb/jam
Jumlah udara masuk : 212.96 Kg udara kering/Jam
r solid = 2631.67 Kg/m3 = 164.28979 lb/ft3
Tekanan operasi : 1 atm = 0.101 N/mm2
Suhu udara masuk : 105 C
o
221 F
Suhu udara keluar : 80 C
o
176 F
Suhu bahan masuk : 48.5 oC 119.3 F
Suhu bahan keluar : 75 C
o
167 F

1. Menentukan Ukuran Rotary Dryer


Berat material dalam dryer (w) = 16887 lbs
Densitas bahan = 164.28979 lb/ft3
Volume bahan dalam dryer = berat bahan
densitas bahan
= 102.8 ft3
Volume padatan dalam dryer adalah 15% dari total volume dryer (perry7ed, 12-54)
maka, volume dryer adalah : 685.25663 ft3
Vs = 1/4 𝜋 𝐷_(𝑖 )
^2 𝐻
ratio L/D yang dianjurkan yaitu 4-10 (perry's 7ed, halaman 12-54), ratio yang di
pilih yaitu, L / = 4
Vs = 𝜋 𝐷^3
D = 6.0206198 Ft = 1.8350849 m

Length of Rotary Dryer


Panjang rotary dryer = 24.08 ft = 7.3403396 m
3. Flight Desain
Jumlah Flight pada rotary dryer adalah 3 x Ukuran Diameter (ft), maka :
Flight =18.061859 (perry's 7ed, hal.12-56)

4. Tinggi Flight
Tinggi Flight pada rptary dryer adalah 1/20 sampai 1/8 dari ukuran diameter (ft),
dipilih 1/8 .
Tinggi flight = 0.7525775 ft (perry's 7ed, hal.12-56)

5. Tebal Shell
material yang digunakan untuk rotary dryer adalah carbon steel SA 283 grade C
dengan alasan pemilihan karena tahan terhadap temperatur operasi dryer yaitu 105oC
(Brownell and young, page 253)

Las dipakai double welded butt joint, dengan E = 0.8


Allowable Stress : 12650 psi 87.1585 N/mm2
Faktor Korosi = 0.125
Tekanan Desain = 1,5 x Tekanan Operasi = 0.1515 N/mm2
t= pxD
2xfxe+p
dimana : t= 1.874 mm
t = tebal shell (mm)
p = tekanan desain (N/mm2)
D = Diameter dryer (mm)
F = Allowable Stress (N/mm2)
E= 0.8

maka, diameter luar dryer adalah Diameter dalam + Ketebalan Shell :


Diameter luar = D2 = 1837 mm
= 1.837 m = 6.0267696 ft
6. Kecepatan Putaran Rotary Dryer
power = r x (4,75 x d x w + 0,1925 x D x W + 0,33 x W)
100000 (perry 7ed, eq. 12-60)
dimana : r = rpm of dryer ( rpm )
d = shell diameter (ft)
W = Berat total dryer (lb)
w = Berat material (lb)
D = diameter cincin dryer (D+2, ft)
Daya Dryer = 10.41 kW = 13.953193 BHP
menghitung berat total dryer
Berat shell dryer = volume shell dryer x densitas bahan
densitas carbon steel = 480 lbs/ft3 , maka :
Berat shell dryer = 328923.18 lbs
Berat material dalam dryer = 16887 lb/jam

Berat total dryer = Berat shell dryer + berat material dalam dryer
W = 345810 lbs
Menghitung Shell Diameter
Shell diameter = Diameter inner dryer + 2 8.02 ft

maka, Kecepatan Putaran Rotary Dryer = 1.20 rpm

7. Daya yang dipakai oleh Blower


Laju alir udara 212.9628284 kg/jam
densitas 1.1676 kg/m3
volume udara =182.3936523 m3/jam
= 3.0399 m3/menit
= 107.350824 ft3/menit
Fan Operating Pressure = 14.658804 psi
Daya yang dibutuhkan untuk menggerakkan poros motor :
HP = 1.57x10-4 x Q x P (perry's 7ed eq.10-88)
HP = 0.25 hp
Efisiensi blower 40% - 70% (Perry, hal 10-46)
Dipakai 70% HP = 0.353 hp 0.2632960598 KW
8. Daya yang dipakai oleh Exhaust Fan
Temperatur bahan keluar= 75 C 348 K
Laju alir bahan = 7,659.94 kg/jam
Temperatur udara pendingin = 30 C 303 K
volume udara yang dibutuhkan untuk mendinginkan 3280.0464 m3/jam
Fan Operating Pressure = 14.658804 psi
Daya yang dibutuhkan untuk menggerakkan poros motor :
HP = 1.57x10-4 x Q x P (perry's 7ed eq.10-88)
HP = 7.55 hp
Efisiensi blower 40% - 70% (Perry, hal 10-46)
Dipakai 70%
HP = 10.784 hp 8.0448688 KW

RESUME (RD-201)
Nama Rotary Dryer
Kode RD-201
Fungsi Membakar sekam padi menjadi abu pada suhu 800oC
Tipe Direct Heat
Volume Rotary Dryer 19.40 m3
Diameter IN 1.84 m
Panjang Shell 7.34 m
Kecepatan Putaran 1.20 rpm
Tebal Shell 1.87 mm
Berat total 156859.54 kg
Diameter OUT 2 m
Daya Rotary Dryer 14 BHP
Daya Blower 1 HP
Daya Exhaust Fan 11 HP
yer (perry7ed, 12-54)

n 12-54), ratio yang di


i ukuran diameter (ft),

steel SA 283 grade C


rasi dryer yaitu 105oC
Fungsi : Memompa Udara menuju rotary dryer
Jenis : blower sentrifugal
Bahan : carbon steel
Kodisi operasi
Temperatur (T) : 105 oC
378.15 K
Tekanan (P) : 1 atm
101325 Pa
14.696 psi
Laju Udara yang masuk : 100037.43 Kg/jam
Densitas Udara 25 Co
: 1.1871870504 kg/m3
(Tabel A.3_3, Geankoplis, 1983)

Laju alir volumetrik O2 = nxRXT


P
= (26480.82 kg/jam x 28.84 kmol/kg) x 1000 x (8.314 m3. Pa/mol.K )x 393.1
101325 Pa
Laju alir volumetrik O2 = 107627.8791589 m3/jam

Daya blower dapat dihitung dengan persamaan,


P = 144 X efisiensi x Laju alir volumetrik
33000
Efisiensi blower sentrifugal berkisar 40-80%, sehingga diambil
η= 70%

P = 144 X 0.7 X 764.805,33


33000
= 328.7542490671 HP

Jika dibuat 2 blower


Fungsi : Memompa Udara menuju Fluidized bed reactor
Jenis : blower sentrifugal
Bahan : carbon steel
Kodisi operasi
Temperatur (T) : 120 oC
393.15 K
Tekanan (P) : 1 atm
101325 Pa
14.696 psi
Laju Udara yang masuk : 100037.43 Kg/jam
Jika dibuat 2 blower 50018.715 kg/jam
BM udara : 28.84 kmol/kg
Densitas Udara 25oC : 1.1871870504 kg/m3
(Tabel A.3_3, Geankoplis, 1983)

Laju alir volumetrik O2 = nxRXT


P
= (26480.82 kg/jam x 28.84 kmol/kg) x 1000 x (8.314 m3. Pa/mol.K )x 393.1
101325 Pa
Laju alir volumetrik O2 = 55948.56629818 m3/jam

Daya blower dapat dihitung dengan persamaan,


P = 144 X efisiensi x Laju alir volumetrik
33000
Efisiensi blower sentrifugal berkisar 69-75%, sehingga diambil
η= 70%

P = 144 X 0.7 X 29620.19


33000
= 170.8974388744 HP
Interpolasi densitas udara
T Densitas(kg/m3)
10 1.246
25 1.1871870504
37.8 1.137

84 kmol/kg) x 1000 x (8.314 m3. Pa/mol.K )x 393.15 K


101325 Pa

84264.25 3468704.23023578
28838806.9701803
10905394855.7737
107627.879158882

84264.253025409
1404.4042170902
49595.130522322
Hp 109.0101
perry 1997
10.46
257.3889910594

Interpolasi densitas udara


T Densitas(kg/m3)
10 1.246
25 1.1871870504
37.8 1.137

84 kmol/kg) x 1000 x (8.314 m3. Pa/mol.K )x 393.15 K


101325 Pa

(Perry, 1997)
APPENDIX C
PERHITUNGAN SPESIFIKASI PERALATAN

Reaktor Sodium Silicate (R-201)


Fungsi : Untuk membuat sodium silikat dari abu sekam padi dengan NaOH
F ρ μ
Komponen X
(Kg/jam) (kg/m3) (cP)
H2O 42,679.48 0.763601 962.99 0.01459
SiO2 8873.38 0.158758 2074 0.9564
Al2O3 74.27 0.001329 3696 28.18
CaO 70.46 0.001261 3030 1.903
MgO 82.84 0.001482 3341 2.703
K2O 365.64 0.006542 2108 1.077
Fe2O3 55.23 0.000988 4921 27.96
NaOH 3691.09 0.066039 1145 0.06597
Total 55892.39 1 21277.98679 62.85996
Volume μ.X
ρ.X
(m3) (cP)
735.3375554 58.0406598 0.011141
329.2648473 26.9490784 0.151836
4.911270661 15.1223995 0.037446
3.819809036 18.4463329 0.002399
4.951799274 16.7292393 0.004006
13.79015458 26.5144159 0.007046
4.862377377 11.3579331 0.027627
75.61494466 48.8143132 0.004357
1172.552758 221.974372 0.245858
Rate Bahan = 55892.39 kg/jam
= 125232 lb/jam

Rho Campuran = 1172.553 kg/m3


= 73.09694 lb/ft3

Q = ṁ
ρCampuran

= 55892.39 kg/jam
1172.55275824 kg/m3
= 47.667269767 m3/jam

Cp = A + BT + CT2 + DT3 + ET5 KJ/Kmol.K

T= 303.15 K
Seyawa a b c d Cp
SiO2 2.48 0.17 -0.00010 217.02
Al2O3 -8.12 0.39 -0.000316 398.03
CaO 10.00 0.00 108,000.00 90,614.04
MgO 10.46 0.11 -0.000080 183.15
K2O 69.26 0.01 2,331,000.00 1,952,081
Fe2O3 24.72 0.02 423,400.00 354,919.1
NaOH 87.64 0.00 -0.0000045 0.000000001 435.58
H2O 92.05 -0.04 -0.0002110 0.000000535 377.49
Na2OSiO2 61.25 0.02 1,545,000.00 - 1,294,249

3.20 SiO2 2.00 NaOH Na2O.3,2SiO2 H2O


m 147.64 92.28 - 2368.45

+ >>> +
b 135.83 84.90 42.45 42.45

s 11.81 7.38 42.45 2410.9

Konversi :
Xa = Mol Bereaksi
Mol Mula-mula
= 0.92

Komponen dHf(KJ/mol) dHf(KJ/Kmol) n(Kmol) dHf(KJ)


SiO2 -910.7 -910700 135.83 -123702357.8
NaOH -416.88 -416880 84.90 -35391072.06
Na2O.3,2SiO2 -1510.88 -1510880 42.45 -64136856
H2O -285.8 -285800 42.45 -12132210
ΔHf Reaktan -1327580
ΔHf Produk -1796680
ΔHRa = ΔHf Produk - ΔHf Reaktan
= -469100 KJ
Analisa Rate Law
Cao = nao 147.64 kmol/jam 3.0974 Kmol/m3
= =
V.Larutan 47.66727 m3/jam

Cbo = nbo 92.28 kmol/jam 1.9359 Kmol/m3


= =
V.Larutan 47.66727 m3/jam

Cao 3.10
=
Cbo 1.94
Cbo = 0.625 Cao
Menghitung Cp Total
∑ Cpt.nt = ∑ Cpi.ni
= ∑ (CpA.nA + CpB.nB + CpC.nC+CpD.nD+CpE.nE)
= (CpA.nao(1-Xa) + (CpB.nbo-nao.Xa) + (CpC.nbo.Xa) +
(CpD.nao.Xa) + (CpE.nao.Xa)
= (CpA.nao(1-Xa) + (CPB.nbo-2(nao.Xa)) +
nao.Xa (CpC+CpD+CpE)
= 55856712 KJ/Kmol

Menghitung Distribusi Temperatur


To = 435.15 K
T = To + ((-ΔHRa)/∑Cpt.nt) x nao x Xa

= 435.15 + 469100
( 55856711.71
) x 147.64 x Xa

Menghitung Nilai Konstanta Reaksi


Diket : To 435 K
A = 8.39E-04
R = 8.3E+00 J/K mol Suyitno, 2009
Ea = 41.24 J/K mol

K = A exp (-Ea/RT) Dalam s-1

= 8.4E-04 x exp ( -41.24 / 8.3E+00 x T)

∫24_0^𝑋�▒���/((−��))
t = Cao
∫24_0^𝑋�▒���/(𝐾.𝐶�.𝐶𝐵2)
= Cao

∫24_0^𝑋�▒���/(𝐾.𝐶�𝑜(1−𝑋�).(𝐶𝑏𝑜−2𝐶�𝑜.𝑋�)2)
= Cao

∫24_0^𝑋�▒���/(𝐾.𝐶�𝑜(1−𝑋�).(2.41 𝐶�𝑜−2𝐶�𝑜.𝑋�)2)
= Cao

∫24_0^𝑋�▒���/(𝐾.4𝐶�𝑜3(1−𝑋�).(1.205−𝑋�)2)
= Cao

Dilakukan penyelesalaian dengan metode numeris dengan menggunakan


persamaan Trapezoidal dengan nilai ΔX = 0.092
t
Xa T (K) K (s-1)
((-1/K*Cbo)*(LN(1-xa)))
0 435.150 8.29E-04 0.000
0.092 435.264 8.29E-04 72.718
0.184 435.378 8.29E-04 153.211
0.276 435.492 8.29E-04 243.343
0.368 435.606 8.30E-04 345.740
0.46 435.720 8.30E-04 464.274
0.552 435.834 8.30E-04 605.001
0.644 435.949 8.30E-04 778.191
0.736 436.063 8.30E-04 1003.458
0.828 436.177 8.30E-04 1326.276
0.92 436.291 8.30E-04 1903.016

Trapezoidal Rule :
Cao x Δx ( y1 + 2y2 + 2y3 + …………. + y9 )
t =
2
t = 3.097 Kmol/m3 x 546.822 m3/Kmol.s
= 1693.7163 s
= 0.4704768 jam

Asumsi : waktu pengisian reaktor (tl) = 0.25 jam


waktu pengosongan reaktor (td) = 0.25 jam

[down time (td)]


t total = t reaksi + tl + tb + tc = 0.4705 + 0.25 + 0.25
= 0.9705 jam

Volume Reaktor

Dimana :
Vt = Volume Reaktor Batch
t = Waktu Reaksi
td = waktu pengosongan reaktor (down time)
P(C) = Laju Alir Pembentukan Produk
vc = Koefisien Produk
Cc = Konsentrasi produk
fa = Konversi

0.9705 jam x 85 Kmol/jam


Vt =
1x 1.78 Kmol/m3 x 0.920

= 50.282584 m3 = 13284.7 gal


= 1775.729 ft3
Dari buku Chemical Engineering Equipment oleh stanley M.walas tabel 18.2 vertical
tank, underwriter label, selected size yang diperoleh untuk nilai Vt tersebut adalah :
Standard Volume = 15000 gal
Standad Height = 39 ft = 11.887 m
Standard Diameter = 8 ft = 2.4384 m
Menghitung Diameter dan Tinggi Tangki menggunakan perhitungan
Perbandingan tinggi shell dengan diameter tangki, Hs 4.875 D
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)

a. Diameter Tangki
Volume tangki = V shell + V tutup
Volume shell (silinder)

Perbandingan Dt : Ht adalah 4.875 Dt , maka Vt = 3.8269 Dt3


Volume Tutup (torispherical)

maka, Vt 4.086875 D3
Dari persamaan tersebut, dapat diketahui diameter dan tinggi tangki
Dt = 7.57405546 ft = 2.3086 m = 90.88958897 in
R = 3.78702773 ft = 1.1543 m = 45.44479449 in
b. Tinggi Tangki
Tinggi tangki = Tinggi shell + Tinggi tutup
Tinggi shell = Ht = 2 Dt, maka :
Ht = 36.9235204 ft = 11.25443 m = 443.0867462 in
Tinggi Tutup
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)
Tinggi tutup =1.89351387 ft = 0.57715 m = 22.722397 in
maka, Tinggi Tangki = 38.81703 ft = 11.83 m = 465.80914 in
Design Tekanan dan Temperatur
a. Tekanan Operasi dan Tekanan Design
Tangki beroperasi pada tekanan atmosferik dan dalam menentukan tekanan
desain harus memperhatikan tekanan hidrostatis cairan didalam vessel.
Tekanan hidrostatis dapat dirumuskan dibawah ini :
Tinggi cairan dalam Tangki = 80% x Tinggi Tangki
= 9.465260726 m
Tekanan Hidrostatis,
P = ρ x g x l Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 1172.55 kg/m3x 9.8 m/s2 x 9.4652607 m
= 108765.472 kg/m.s2
= 15.771 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi + 15.771 Psi
= 30.47099347 Psi

faktor keamanan tekanan 10% dari P design (coulson, Hal 807)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 30.47099347 Psi + 3.0470993 Psi
= 33.51809282 Psi
= 18.82809282 Psig

b. Temperatur Operasi dan Temperatur design


jika temperatur tangki (-20) - 650oF maka temperatur ditambahkan 50oF
(wallas,1990;623)
T operasi = 162.0 oC
= 199.0 oF
maka, T design = 199,04 + 50) oF
= 249.04 oF

Pemilihan Material
Material tangki yang akan digunakan adalah carbon steel SA - 283 grade C.
Pemilihan ini didasari atas pertimbangan bahan yang akan disimpan memiliki tingkat
korosi yang cukup tinggi, material dengan bahan tersebut memiliki ketahanan korosi
yang tinggi, mudah dalam pembuatannya.

Design Stress (S)


Untuk material SA-283 grade C yang bekerja pada temperatur 249,04oF
Tensil Strength 12650 Psi
S = 12650 Psi (Sumber : brownell and young hal 251)

Corrosion Allowance
Untuk mengantisipasi reaktan yang bersifat korosi,
diset corrosion allowance sebesar :
C = 0.015 in / year
(Sumber : timmerhaus hal 542)
Tebal Shell
Untuk mencari ketebalan silinder vessel (shell), digunakan persamaan berikut

(tabel 18.4 wallas hal 658)


Dimana, t = Ketebalan Shell (in)
P = Tekanan (Psi)
R = Jari-jari (in)
S = allowable stress (Psi)
E = Joint Efficiency (0,6-1)
C = Corrosion allowance (in)
(Wallas,2005)
Sehingga tebal sheel tangki diambil nilai E= 0.8 adalah
E=0.8 untuk single-welded butt joint with backing strip
(brown and young hal 253)

ts = 33.51809 Psi x 45.44479 in + 0.015 in


( 12650 Psix 0.8 ) - ( 0.6 x 33.518 Psi )
ts = 0.165816 in
= 0.004212 m
Tekanan maksimum shell

(tabel 18.4 wallas hal 658)

P max = 36.84449 psi = 2.54 Bar

Tebal Head
Jenis Head yang diguakan adalah torispherical head.
Pertimbangan dalam pemilihan jenis head didasari atas
tekanan penyimpanan bahan yang rendah (<=10 bar). (coulson, hal.817)
biaya pembentukan lebih murah (brownel & young,1959)

(tabel 18.4 wallas hal 658)

th = 0.15057 in

h. Perhitungan Pengaduk
µ campuran (m) = 0.25 cp
= 0.00017 lb/ft.sec
ρ campuran ( rho ) = 1172.55 kg / m3
= 73.20 lb/ft3
Digunakan jenis pengaduk adalah flat 6 blade turbin agitator
(hal 142, Geankoplish)
dengan, Da/W = 5 (halaman 158, Geankoplish 4th)
Dt/J = 10
Untuk pengaduk secara umum :
Da/Dt = 03-0.5 (halaman 158, Geankoplish 4th)
H/Dt = 1 (halaman 158, Geankoplish 4th)
C/Dt = 0.33 (halaman 158, Geankoplish 4th)
Dd/Da = 0.67 (halaman 158, Geankoplish 4th)
L/Da = 0.25 (halaman 158, Geankoplish 4th)
W/Da = 0.20 (halaman 158, Geankoplish 4th)
J/Dt = 0.10 (halaman 159, Geankoplish 4th)
Dimana :
Da = Diameter pengaduk
W = Lebar blade
Dt = Diameter tangki
J = Lebar Baffle
H = Tinggi cairan dalam tangki
C = Tinggi pengaduk dari dasar tangki
Dd = Panjang tangkai pengaduk
L = Panjang blade
digunakan diameter pengaduk : diameter tangDa/Dt 0.5 (geankoplish, 142)
D pengaduk (Da) = 0.5 x 90.89 in
= 45.44 in 3.79 ft
Lebar Blade (W) = 0.2 Da
= 9.09 in 0.76 ft
Panjang Blade (L) = 0.25 Da
= 11.36 in 0.95 ft
Tinggi Pengaduk = 0.33 x 90.89 in
dari dasar tanki = 29.99 in
= 2.50 ft
Panjang Tangkai = 0.67 Da
= 30.45 in
= 2.54 ft
i. Menentukan Jumlah Impeller
∑ impeller = tinggi cairan / diameter tangki
= 29.5388 ft
7.57 ft
= 3.9 impeller
= 2 impeller
j. Menentukan Daya Pengaduk
Daya pengaduk homogenous = (0,5 hp / 1000 gal) x V
sehingga daya pengaduk yang akan digunakan (Wallas,
: hal.292)
V = 0.0 ft3
= 0.00 gal
P = 0.5 x 0.00 gal
1000
= 0.00 hp Effisiensi motor = 0.8
= 0.0 lbf.ft/s Daya motor = 0.00 hp

k. Menentukan kecepatan pengaduk


Dari hal 292 wallas untuk pengadukan, tip speed 7,5-10 ft/detik
rps = 10
π Da
= 0.84 rps
= 50.46 rpm

l. Jaket
Dari neraca panas, jumlah air pendingin yang diperlukan
Fp = 173371.1 kmol/jam = 3120679.285248 kg/jam
Densitas air = 1023.01299 kg/m3
Vp = 169.471037 m3/jam

Jarak jaket (γ) = 1/2 in = 0.013 m


Tebal dinding tangki :
Diameter in (D1) = D + Tebal tangki
= 91.0554 in
= 2.3128 m
Diameter out (D2) = 2γ + D1
= 2.3382 m 92.0554047686 in
Luas Area (A) = π/4 x (D22 - D12)
= 0.0927 m2
Kecepatan air pendingin (v),
Vp
v= = 1827.438 m/jam
A
Tebal dinding jaket (dj)
Direncanakan menggunakan bahan konstruksi Carbon Steel SA 283 grade C
Diperoleh data :
Joint efficiency ( E ) = 0.8
Allowable Stress (S) = 12650 psia
Umur Alat (n) = 10 tahun
Faktor korosi (CA) = 0.02 in/tahun
Tebal jaket (dj) : dj =𝑃𝑅/(𝑆𝐸 −0,6 𝑃) + nCA

dimana :
dj = Tebal jaket (in)
P = Tekanan design (Psi)
R = jari - jari dalam tangki (in) = D/2
S = Allowable Working Stress
CA = Corrosion Allowance
n = umur alat yang direncanakan
E = Effisiensi sambungan

Tekanan Hidrostatis,
P = ρxgxl Dimana,
ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 1023.01 kg/m3x 9.8 m/s2 x 9
= 94894.2 kg/m.s2
= 13.7596633 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi + 13.76 Psi
= 28.45966329 Psi

faktor keamanan tekanan 10% dari P design (Wallas, Hal 688)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 28.45966329 Psi + 2.8459663 Psi
= 31.30562962 Psi
= 16.61562962 Psig

dj =𝑃𝑅/(𝑆𝐸 −0,6 𝑃) + nCA

dj = 0.225699 in
dipilih tebal jaket standar 1/2 in (brownel & young 1959)

RESUME (R-201)
Nama Reaktor Sodium Silikat
Kode R-201
Fungsi Tempat terjadi reaksi dan pembentukan sodium silikat
Tipe Silinder tegak, torispherical roof dishead head
Bahan Carbon Steel SA-283 grade C
Jumlah 1 buah
Volume tanki 50.3 m3
Diameter tanki 2.31 m
Tinggi silinder 11.25 m
Tinggi head 0.58 m
Tebal shell 0.004 m
Tinggi total 11.83 m
Jenis Pengaduk Turbine Agitator
Jumlah Blade 6 blade
Jumlah impeller 2 impeller
Diameter pengaduk 1.15 m
Lebar Blade 0.23 m
Panjang Blade 0.29 m
Tinggi dari dasar tanki 0.76 m
Panjang Tangkai 0.77 m
Daya Pengaduk 4.00 hp
Kecepatan Pengaduk 50.46 rpm
Luas Area Jaket 0.09 m2
Tebal Jaket 0.23 in
Kecepatan Air 1827.44 m/jam
900
0.00083 300
0.00083 A -41.24
3933.769 3617.837
0.00083 A -0.01048
0.00083 -2.9E-06
A 0.989571
A 8.39E-04 0.00E+00
0.999997
K 0
M.walas tabel 18.2 vertical
nilai Vt tersebut adalah :
am menentukan tekanan
n steel SA - 283 grade C.
disimpan memiliki tingkat
memiliki ketahanan korosi
bon Steel SA 283 grade C
473.15
573.15
Reaktor CSTR (R-202)
Fungsi = Tempat terjadinya reaksi pembentukan SiO2
Jenis = CSTR
Bentuk = Silinder vertikal dengan alas dan tutup torispherical

Bahan Konstruks= Carbon Steel SA 283 grade C


Jumlah = 1 unit
Reaksi yang terjadi
Na2O.3,2 SiO2 + H2SO4 3,2 SiO2 + Na2SO4 + H2O
Temperatur masuk = 92.80 oC(Sodium Silicate)
92.80 oC(Asam Sulfat)
Temperatur keluar = 92.80 oC
Tekanan operasi = 1 atm

Komposisi umpan masuk reaktor


Laju alir Laju alir Laju alir
ρ Viskositas
Komponen Massa Mol %Berat Volume
(kg/jam)(kmol/jam) (kg/m3) (m3/jam) (Cp)
H2SO4 3829.024 39.052 0.0644 1748.48 2.1899 4.74978
Air 45438.04 4739.56 0.7641 962.987 47.1845 0.27791
Na2O.3,2 SiO2 9930.860 39.052 0.1670 2610 3.8049 50
NaOH 271.6643 6.792 0.0046 1881.94 0.1444 1.6E-06
Total 59469.58 4824.45 1.0000 53.32
Densitas Campuran : Viskositas Campuran
ρ0 Campuran
= ∑ %berat x ρi μ Campuran = ∑ %berat x μi
= 1292.795 kg/m3 = 8.86769 Cp
= 0.00887 Kg/m.s
Waktu tinggal di reaktor
t = 0.333333 jam (US Patent 4248600)
t= 𝑉/�
(Persamaan 2.3.2, Missen)
V = ṁ �𝑜��� 𝑥 t/(ρ ��𝑚𝑝𝑢𝑟�𝑛)
= 15.3336 m3= 4050.70 gal= 541.498 ft3
V tangki = 1,2 x Volume Larutan Faktor Kelonggara : 20%
= 4860.846 gal (Tabel 6, Timmerhaus, Hal 37)
= 649.8027 Ft3
Menghitung Diameter dan Tinggi Tangki menggunakan perhitungan
Perbandingan tinggi shell dengan diameter tangki, 1.5 D
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)

a. Diameter Tangki
Volume tangki = V shell + V tutup
Volume shell (silinder)

Perbandingan Ht : Dt adal 1.5 Dt , maka Vt = 1.1775 Dt3


Volume Tutup (torispherical)

maka, Vt = 1.4 D3
Dari persamaan tersebut, dapat diketahui diameter dan tinggi tangki
Dt = 7.674638 ft = 2.33926 m = 92.0966 in
R = 3.837319 ft = 1.16963 m = 46.0483 in
b. Tinggi Tangki
Tinggi tangki = Tinggi shell + Tinggi tutup
Tinggi shell = Ht = 1,4 Dt, maka :
Ht = 11.512 ft = 3.50889 m = 138.145 in
Tinggi Tutup
Perbandinngan tinggi tutup dengan diamater tangki, T : D = 1 :4
(Brownell & Young, 1979 halaman 80)
Tinggi tutup 1.91866 ft =0.58481 m = 23.0241 in
maka, Tinggi Tangki = 13.4306 ft = 4.0937 m = 161.169 in

Design Tekanan dan Temperatur


a. Tekanan Operasi dan Tekanan Design
Tangki beroperasi pada tekanan atmosferik dan dalam menentukan tekanan
desain harus memperhatikan tekanan hidrostatis cairan didalam vessel.
Tekanan hidrostatis dapat dirumuskan dibawah ini :
Tinggi cairan dalam Tangk= 80% x Tinggi Tangki
= 3.27496 m
Tekanan Hidrostatis,
P = ρxgxl Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 1292.80 kg/m3x 9.8 m/s2 x 3.27496 m
= 41491.78 kg/m.s2
= 6.016 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi
Sehingga, P total = Po + Phidrostatis
= 14.7 Psi+ 6.016 Psi
= 20.7163 Psi

faktor keamanan tekanan 10% dari P design (coulson, Hal 807)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 20.7163 Psi + 2.07163 Psi
= 22.7879 Psi
= 8.09794 Psig

b. Temperatur Operasi dan Temperatur design


jika temperatur tangki (-20) - 650oF maka temperatur ditambahkan 50oF
(wallas,1990;623)
T operasi = 92.80 oC
= 199.0 oF
maka, T design = 199,04 + 50) oF
= 249.04 oF

Pemilihan Material
Material tangki yang akan digunakan adalah carbon steel SA - 283 grade C.
Pemilihan ini didasari atas pertimbangan bahan yang akan disimpan memiliki tingkat
korosi yang cukup tinggi, material dengan bahan tersebut memiliki ketahanan korosi
yang tinggi, mudah dalam pembuatannya.

Design Stress (S)


Untuk material SA-283 grade C yang bekerja pada temperatur 249,04oF
Tensil Strength 12650 Psi
S = 12650 Psi (Sumber : brownell and young hal 251)

Corrosion Allowance
Untuk mengantisipasi reaktan yang bersifat korosi,
diset corrosion allowance sebesar :
C = 0.015 in / year
(Sumber : timmerhaus hal 542)
Tebal Shell
Untuk mencari ketebalan silinder vessel (shell), digunakan persamaan berikut

(tabel 18.4 wallas hal 658)


Dimana, t = Ketebalan Shell (in)
P = Tekanan (Psi)
R = Jari-jari (in)
S = allowable stress (Psi)
E = Joint Efficiency (0,6-1)
C = Corrosion allowance (in)
(Wallas,2005)

Sehingga tebal sheel tangki diambil nilaE = 0.8 adalah


E=0.8 untuk single-welded butt joint with backing strip
(brown and young hal 253)

ts = 22.78794 Psi x 46.0483 in + 0.015 in


( 12650 Psix 0.8 ) - ( 0.6 x 22.79 Psi)
ts = 0.118831 in
= 0.003018 m

Tekanan maksimum shell

(tabel 18.4 wallas hal 658)

P max = 26.0749 psi

Tebal Head
Jenis Head yang diguakan adalah torispherical head.
Pertimbangan dalam pemilihan jenis head didasari atas
tekanan penyimpanan bahan yang rendah (<=10 bar). (coulson, hal.817)
biaya pembentukan lebih murah (brownel & young,1959)

(tabel 18.4 wallas hal 658)

th = 0.103714 in

h. Perhitungan Pengaduk
µ campuran (m) = 8.87 cp
= 0.00596 lb/ft.sec
ρ campuran ( rho ) = 1292.80 kg / m3
= 80.71 lb/ft3
Digunakan jenis pengaduk adalah flat 6 blade turbin agi(hal 142, Geankoplish)

dengan, Da/W = 5 (halaman 158, Geankoplish 4th)


Dt/J = 10
Untuk pengaduk secara umum :
Da/Dt = 03-0.5(halaman 158, Geankoplish 4th)
H/Dt = 1 (halaman 158, Geankoplish 4th)
C/Dt = 0.33 (halaman 158, Geankoplish 4th)
Dd/Da = 0.67 (halaman 158, Geankoplish 4th)
L/Da = 0.25 (halaman 158, Geankoplish 4th)
W/Da = 0.20 (halaman 158, Geankoplish 4th)
J/Dt = 0.10 (halaman 159, Geankoplish 4th)
Dimana :
Da = Diameter pengaduk
W = Lebar blade
Dt = Diameter tangki
J = Lebar Baffle
H = Tinggi cairan dalam tangki
C = Tinggi pengaduk dari dasar tangki
Dd = Panjang tangkai pengaduk
L = Panjang blade
digunakan diameter pengaduk : diameter tangDa/Dt 0.5 (geankoplish, 142)
D pengaduk (Da)= 0.5 x 92.10 in
= 46.05 in 3.84 ft
Lebar Blade (W) = 0.2 Da
= 9.21 in 0.77 ft
Panjang Blade (L= 0.25 Da
= 11.51 in 0.96 ft
Tinggi Pengaduk = 0.33 x 92.10 in
dari dasar tanki = 30.39 in
= 2.53 ft
Panjang Tangkai = 0.67 Da
= 30.85 in
= 2.57 ft
i. Menentukan Jumlah Impeller
∑ impeller = tinggi cairan / diameter tangki
= 9.2096 ft
7.67 ft
= 1.2 impeller
= 2 impeller
j. Menentukan Daya Pengaduk
Daya pengaduk homogenous = (0,5 hp / 1000 gal) x (VWallas, hal.292)
sehingga daya pengaduk yang akan digunakan :
V = 649.8 ft3
= 4860.85 gal
P = 0.5 x 4860.85 gal
1000
= 2.43 hp Effisiensi motor= 0.8
= 1336.7 lbf.ft/s Daya motor = 3.04 hp
k. Menentukan kecepatan pengaduk
Dari hal 292 wallas untuk pengadukan, tip speed 7,5-10 ft/detik
rps = 10
π Da
= 0.83 rps
= 49.80 rpm
I. Jaket
Dari neraca panas, jumlah air pendingin yang diperlukan
Fp = 183021.1 kmol/jam= 3294379.43 kg/jam
Densitas air = 1023.013 kg/m3
Vp = 178.904 m3/jam

Jarak jaket (γ = 1/2 in = 0.013 m


Tebal dinding tangki :
Diameter in (D1)= D + Tebal tangki
= 92.2154 in
= 2.3423 m
Diameter out (D2= 2γ + D1
= 2.3677 m 93.2154 in
Luas Area (A) = π/4 x (D22 - D12)
= 0.0939 m2
Kecepatan air pendingin (v),
Vp
v= = 1905.02 m/jam
A
Tebal dinding jaket (dj)
Direncanakan menggunakan bahan konstruksi Carbon Steel SA 283 grade C
Diperoleh dat :
Joint efficiency ( E = 0.8
Allowable Stress (S = 12650 psia
Umur Alat (n) = 10 tahun
Faktor korosi (CA) = 0.02 in/tahun
Tebal jaket (dj) : dj =𝑃𝑅/(𝑆𝐸 −0,6 𝑃) + nCA

dimana :
dj = Tebal jaket (in)
P = Tekanan design (Psi)
R = jari - jari dalam tangki (in) = D/2
S = Allowable Working Stress
CA = Corrosion Allowance
n = umur alat yang direncanakan
E = Effisiensi sambungan
Tekanan Hidrostatis,
P = ρxgxl Dimana, ρ = Densitas Cairan (Kg/m3)
g = Gaya gravitasi (m/s2)
l = Tinggi cairan (m)
P = 1023.01 kg/m3x 9.8 m/s2 x 3.27496 m
= 32833.2 kg/m.s2
= 4.760816 Psi
Dimana Tekanan Operasi = 1 atm
= 14.7 Psi

Sehingga, P total = Po + Phidrostatis


= 14.7 Psi+ 4.761 Psi
= 19.4608 Psi

faktor keamanan tekanan 10% dari P design (Wallas, Hal 688)


Sehingga, P design = P total + (P total x faktor kelonggaran)
= 19.4608 Psi + 1.94608 Psi
= 21.4069 Psi
= 6.7169 Psig

dj =𝑃𝑅/(𝑆𝐸 −0,6 𝑃) + nCA

dj = 0.18097 in
dipilih tebal jaket standar 1/2 in (brownel & young 1959)

RESUME (R-202)
Nama Reaktor Precipitated Silica
Kode R-202
Fungsi Tempat terjadi reaksi dan pembentuka precipitated silica
Tipe Silinder tegak, torispherical roof dishead head
Bahan Carbon Steel SA-283 grade C
Jumlah 1 buah
Volume tanki 18.4 m3
Diameter tanki 2.34 m
Tinggi silinder 3.51 m
Tinggi head 0.58 m
Tebal shell 0.003 m
Tinggi total 4.09 m
Jenis Pengaduk Turbine Agitator
Jumlah Blade 6 blade
Jumlah impeller 2 impeller
Diameter pengaduk 1.17 m
Lebar Blade 0.23 m
Panjang Blade 0.29 m
Tinggi dari dasar ta 0.77 m
Panjang Tangkai 0.78 m
Daya Pengaduk 3.00 hp
Kecepatan Pengadu 49.80 rpm
Luas Area Jaket 0.094 m2
Tebal Jaket 0.18 in
Kecepatan Air 1905.02 m/jam
alam menentukan tekanan
on steel SA - 283 grade C.
an disimpan memiliki tingkat
ut memiliki ketahanan korosi

nakan persamaan berikut


rbon Steel SA 283 grade C
(brownel & young 1959)
dipilih 20 ft/detik
LAMPIRAN C
SPESIFIKASI ALAT

Rotary Kiln (RK-01)


Fungsi : Membakar sekam padi pada suhu 800C
Jenis : Rotary Kiln
Bahan : Carbon Steel SA 515

Jumlah Bahan Umpan 52,461.82 Kg/Jam 115657 lb/jam


Jumlah udara masuk : 9,016.35 Kg udara kering/Jam
Tekanan operasi : 1 atm = 0.101 N/mm2
Suhu udara masuk : 30 oC 86 F
Suhu udara keluar : 162 oC 323.6 F
Suhu bahan masuk : 30 oC 86 F
Suhu bahan keluar : 162 oC 323.6 F

1. Menentukan Ukuran Rotary Kiln


Laju alir sekam padi = 52,461.82 Kg/Jam
= 115657.32608069 lb/jam
= 52.4618 ton/jam
Dari tabel 12-20 Perry's 7 ed hal. 12-59, didapat spesifikasi untuk
diameter dan panjang rotary kiln dengan kapasitas tersebut adalah :
Diameter : 8 ft 2.4384 m
Panjang : 140 ft 42.672 m

2. Kecepatan Putaran Rotary Kiln


Shell pheriperal speed untuk rotary kiln adalah 60-75 ft/min
dipilih shell pheriperal speed yaitu 75 ft/min
(perry's 7ed, hal. 12-54)
dengan besaran rotasi per menit (rpm)

vr = sheel speed = 75 = 9.375 rpm


D 8.00

6. Tebal Shell
Material yang digunakan untuk rotary dryer adalah High Alloy Steel 316
dengan alasan pemilihan karena tahan terhadap temperatur operasi kiln yaitu 800oC
(perry's 5ed tabel. 6-57)

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


LAMPIRAN C
SPESIFIKASI ALAT

Las dipakai double welded butt joint, dengan E = 0.8


Allowable Stress : 18700 psi 128.843 N/mm2
Faktor Korosi = 0.125
Tekanan Desain = 1,5 x Tekanan Operasi = 0.1515 N/mm2
t= pxD
2xfxe+p
dimana : t= 1.79068 mm
t = tebal shell (mm)
p = tekanan desain (N/mm2)
D = Diameter dryer (mm)
F = Allowable Stress (N/mm2)
E= 0.8

maka, diameter luar dryer adalah Diameter dalam + Ketebalan Shell :


Diameter luar = D2 = 2440.19 mm = 2.44019068 m
= 8.00587519 ft
7. Kebutuhan Daya Rotary Dryer

power = r x (4,75 x d x w + 0,1925 x D x W + 0,33 x W) (perry 7ed, eq. 12-60)


100000
dimana : r = rpm of dryer ( rpm )
d= shell diameter (ft)
W = Berat total dryer (lb)
w= Berat material (lb)
D= diameter cincin dryer (D+2, ft)

menghitung berat total dryer


Berat shell dryer = volume shell dryer x densitas bahan
volume shell dryer = (πD2 - πD1 ) x L
2 2

4
= #REF! ft3
densitas carbon steel = 480 lbs/ft3 , maka :
Berat shell dryer = #REF! lbs
menghitung berat material dalam dryer
asumsi padatan mengisi 15% dryer (perry's 7 ed, hal. 12-54)

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


LAMPIRAN C
SPESIFIKASI ALAT

volume material pada dryer = ( πD1^2 x L) x 0,15


4
= #REF! ft3

berat material dalam dryer (w) = 115657 lbs

Berat total dryer = Berat shell dryer + berat material dalam dryer
W = #REF! lbs

Menghitung Shell Diameter


Shell diameter = Diameter inner dryer + 2 #REF! ft

maka, daya yang dibutuhkan oleh dryer = #REF! BHP


= #REF! KW

8. Daya yang dipakai oleh Blower


Laju alir udara = 9016.3546793 kg/jam
densitas = 1.1676 kg/m3
volume udara = 7722.1263098 m3/jam
= 128.70210516 m3/menit
= 4544.986142 ft3/menit
Fan Operating Pressure = 14 inches water coloumn (fan system
Daya yang dibutuhkan untuk menggerakkan poros motoroperating point grafik)
HP = 1.57x10-4 x Q x DP (perry's 7ed eq.10-88)
HP = 9.99 hp
Efisiensi = HP blower/ HP poros
Efisiensi blower 40% - 70% (Perry, hal 10-46)
Dipakai 70%
HP Poros = 6.9929 hp 5.216715 KW

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


LAMPIRAN C
SPESIFIKASI ALAT

tur operasi kiln yaitu 800oC

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


LAMPIRAN C
SPESIFIKASI ALAT

JURUSAN TEKNIK KIMIA UNIVERSITAS SULTAN AGENG TIRTAYASA


Rotary Dryer

fungsi : mengeringkan bahan yang keluar dari cristalizer dengan bantuan udara panas
dasar pemilihan : sesuai untuk pengeringan padatan
kondisi operasi : P = 1 atm
suhu umpan : 48,5 oC
suhu udara : 105

perhitungan :
dari neraca massa dan neraca panas :
feed masuk = 20870.03728552 kg/jam
46010.08419965 lb/jam
total panas = 771222837.5923 kj/jam
730965005.47 btu/jam
suhu bahan masuk = 48.5 C 86 F
suhu bahan keluar = 60 185
suhu udara masuk = 105 302
suhu udara keluar = 60 185

delta T lmtd
∆ t1= 117
∆ t2= 99

∆ T lmtd =( ∆t2-∆t1)/ ln( ∆t2/∆t1)


( ∆t2-∆t1) = -18
ln( ∆t2/∆t1) = -0.1670540847
∆ T lmtd = 107.74953535 F
315 K
perhitungan area of drum
asumsi solid velocity, us = 1.2 m/detik (ulrich,table 4-10)
area aliran solid , As = ms/(ρs x us)
keterangan
As = area drum yang dilewati solid (m2)
ms = rate solid (kg/dt)
ρs= densitas solid (kg/m3)
us = solid velocity (m/dt)

ms = 20870.037286 kg/jam
5.7972325793 kg/detik
ρs,campuran= 1.7644957386 kg/m3
us = 1.2 m/detik
As = 2.7379080854 m2
As = 0.785 D^2
2.7379080854 = 0.785 D^2
D^2 = 3.4877810005
D = 1.8675601732 m
perhitungan koefisies volumetri heat transfer,(Ua) =
Ua = 240 x G ^0,67
D
keterangan :

G (asumsi ) = 0.1 Kg/dt.m2


D = 1.8675601732
Ua = 27.474932741 J/m3.dt.K

perhitungan panjang rotary drum :


V = 2.7379080854 L
total panas pada sistem
Q = 214228.566 Kj/dt
Ua = 27.474932741 J/m3.dt.K
D= 1.8675601732 m
∆ T lmtd = 315

214228.565997854 = 27.474932741 x 2.737908 L


214228.565997854 = 23713.03691125 L x 315
L = 9.0342104556 m

perbandinga L/D dryer = 4-10 (Perry, 12-54)


L/D = 4.8374400918

karena L/D dryer memenuhi range yang ditentukan, maka pengambilan nilai
us=1,2 dan G=0,1 kg/dt.m2 dapat di terima (trial us dan G sampe nilai L/D 4-10)
B= 205 (blm tw dari mana)
A drum = 2.7379080854 m2
F = 7622.6215909 kg/jam.m2
Ǿ = 0.027727922 + 0.014578
0.0423056873 menit
perhitungan sudut rotary
slop = 8 cm/m
panjang drum = 9.0342104556 m
slop actual = 72.273683645 cm = 0.722737 m
tg alpha = 0.7227368364
0.8819217057 mendekati 1 derajat
diameter drum, D = 1.8675601732 m
panjang drum, L = 9.0342104556 m
tinggi flight = 1/8 D = 0.2334450216 m
jumlah flight 1 circle = 3 D = 5.6026805196 buah digunakan 6
total circle = panjang drum/panjang flight buah
total circle = 4.5171052278 digunakan 5 buah
total jumlah flight = total circle x jumlah flight tiap 1 circle
total jumlah flight = 30

D= 1.8675601732 m = 6.127091 ft
H = 0,16 x D = 0.9803346266 ft
ρ (bulk densitas bahan) = 165.4 lb/cuft

tekanan vertikal pada tangki


Zr = 0.147050194 ft
r (jari-jari tangki ), ft = D/2 = 3.0635457081 ft

PB= 2.7
tekanan lateral PL= k x PB = 0.9018 psi
P operasi = PB+PL = 3.6018 psi
untu faktor keamanan 10 %, digunakan tekan:
P aktual = 3.96198 psi
4 psi

ts = 0.0011182864 + 0.125
ts = 0.1261182864 inch
digunakan 0.1875 (3/16)

isolasi
batu isolasi dipakai setebal 4 inch (Perry ed.7; 12-42)
diameter dalam rotary = 6.1270914162 ft
diameter luar rotary = 6.1583414162 ft
maka diameter rotary terisolasi = 6.8250080829 ft

perhitungan power rotary :


(perry ed.6 ) persamaan 20-44

dengan:
N, putaran rotary = 6 rpm
d, diameter shell = 6.1270914162 ft
w, berat bahan = 19715.678604 kg/jam
43473.071322 lb
D = d+2 = 8.1270914162 ft

Do = diameter luar shell = 6.1583414162 ft


Di = diameter dalam shell = 6.1270914162 ft
L = panjang drum = 9.0342104556 m = 29.63944 ft
ρ (densiti steel) = 482 lb/cuft
WE = 4305.5351411 lb

b ) berat isolasi

Do = diameter luar isolasi = 6.8250080829 ft


Di = diameter dalam isolasi = 6.1583414162 ft
L = panjang isolasi = 29.639437663 ft
ρ (densiti isolasi) = 19 lb/cuft
WE = 3826.3853612 lb

c) berat bahan dalam drum


untuk solid hold-up = 15 % (ulrich T.4-10)
rate massa = 43473.071322 lb/jam
berat bahan = 49994.03202 lb
berat total = 58125.952523 lb
berat lain diasumsikan 15 %, maka berat total = 66844.85 lb
hp = 93.354628935 hp
dengan effeciency motor = 75 % ( Perry ed.6, p.20-37), maka:
P= 124.47283858 = 125

spesifikasi :
kapasitas = 20870.037286 kg/jam
isolasi = batu isolasi
diameter = 1.8675601732 m
panjang = 9.0342104556 m
tebal isolasi = 4 inch
tebal shell = (3/16) inch
tinggi bahan = 0.147050194 ft
sudut rotari = 1 derajat
time of passes = 0.0423056873 menit
jumlah flight = 30
power = 125 Hp
jumlah= 1 buah