C-0201 The upper limit sensor /1 (PS6) does not turn ON within a specified period of time
after the paper lift motor /1 (M7) turns ON. Paper lift motor /1 (M7) Upper limit sensor /1 (PS6)
Printer control board (PRCB)
C-0202 The upper limit sensor /2 (PS13) does not turn ON within a specified period of time
after the paper lift motor /2 (M8) turns ON.
Paper lift motor /2 (M8) Upper limit sensor /2 (PS13) Printer control board (PRCB)
C-0203 The upper limit sensor /3 (PS114) does not turn ON within a specified period of time
after the paper lift motor /3 (M124) turns ON.
Paper lift motor /3 (M124) Upper limit sensor /3 (PS114) PC control board (PCCB)
C-0204 The upper limit sensor /4 (PS123) does not turn ON within a specified period of time
after the paper lift motor /4 (M125) turns ON.
Paper lift motor /4 (M125) Upper limit sensor /4 (PS123) PC control board (PCCB)
C-0205 The upper limit sensor (PS152) does not turn ON within a specified period of time
after the paper lift motor (M151) turns ON. Paper lift motor (M151) Upper limit sensor (PS152)
LU drive board (LTDB)
C-0206 Paper lift motor (M5) abnormality. Shift motor (M4) abnormality. Shift gate motor (M3)
abnormality. Paper lift motor (M5) Shift motor (M4) Shift gate motor (M3) PC control board
(PCCB)
C-0207 While in the paper feed, there occurs a condition twice in succession in which the lift
sensor (PS23) does not turn ON within a specified period of time after the pick-up solenoid /BP
(SD1) turns ON. While in the power switch (SW2) ON, there occurs a condition twice in
succession in which PS23 does not turn OFF within a specified period of time after SD1 turns
ON. Pick-up solenoid /BP (SD1) Lift sensor (PS23) Feed motor (M9) Printer control board
(PRCB)
C-1002 FS
- FS communication abnormality. A serial communication is unavailable between the FS control
board (FSCB) and the printer control board (PRCB). FS control board (FSCB) Printer control
board (PRCB)
C-1003 FS-522
- Flash ROM abnormality. A checksum error of the flash ROM is detected. FS control board
(FSCB)
C-1104 FS-523: Paper exit roller release motor (M13) drive abnormality.
- When starting the pressure position drive, the exit roller home sensor (PS13) does not turn ON
within a specified period of time after M13 turns ON.
- When starting the separation position drive, PS13 does not turn OFF within a specified period
of time after M13 turns ON. Paper exit roller release motor (M13) Exit roller home sensor (PS13)
FS control board (FSCB)
C-1105 FS-523: Intermediate conveyance roller release motor (M12) drive abnormality.
- When starting the pressure position drive, the roller release home sensor (PS12) does not turn
ON within a specified period of time after M12 turns ON.
- When starting the separation position drive, PS12 does not turn OFF within a specified period
of time after M12 turns ON. Intermediate conveyance roller release motor (M12) Roller release
home sensor (PS12) FS control board (FSCB)
C-1120 FS-523: Hole punch selector motor (M14) drive abnormality (inch system only)
- When starting the punch 2- hole position switch drive, the hole punch position switch (SW4) is
not turned ON in the specified period of time after the M14 is turned ON.
- When starting the punch 3- hole position switch drive, the SW4 is not turned OFF in the
specified period of time after the M14 is turned ON. FS control board (FSCB) Hole punch
selector motor (M14)
C-2803 E6 When the detection of the toner control patch is abnormal for the D/A check IDC
sensor (IDCS) Printer control board (PRCB)
- While in the idle, the fusing heater lamp /2 (L3) turns on for more than 12 seconds in
succession. Thermistor /2 (TH2) Printer control board (PRCB) DC power supply (DCPS)
C-3807 Fusing main sensor high temperature abnormality (sub CPU detection)
- In the sub CPU, the thermistor /1 (TH1) detects a temperature higher than 236 °C for more
than a specified period of time. Thermistor /1 (TH1) Printer control board (PRCB) DC power
supply (DCPS)
C-3808 Fusing sub sensor high temperature abnormality (sub CPU detection)
- In the sub CPU, the thermistor /2 (TH2) detects a temperature higher than 236 °C for more
than a specified period of time. Thermistor /2 (TH2) Printer control board (PRCB) DC power
supply (DCPS)
- There is no response 2 times in succession to the A/D conversion request of the overall
control board (OACB). Printer control board (PRCB)
C-5401 There occurs an OS error with the engine control section in the printer control board
(PRCB). Printer control board (PRCB)
C-5402 Time out for tuning off the power switch (SW2) Overall control board (OACB) Printer
control board (PRCB)
C-6001 CCD board (CCDB) connection abnormality. CCD board (CCDB) Overall control
board (OACB)
C-6002 Communication abnormality between the engine control of the overall control board
(OACB) and that of the printer control board (PRCB). While in the stand-by, a scanner Ready
signal cannot be detected for a specified period of time. Overall control board (OACB) Printer
control board (PRCB)
C-6003 Communication abnormality between the engine control of the overall control board
(OACB) and that of the printer control board (PRCB). Time out for the notice time of the platen
original size. Overall control board (OACB) Printer control board (PRCB)
C-6101 While in the exposure unit initial search, the scanner home sensor (PS30) does not turn
on within a specified period of time. And also, while in the return scan, PS30 does not turn on
within a specified period of time. Scanner motor (M2) Scanner home sensor (PS30) Printer
control board (PRCB)
C-8301 Cooling fan (FM3) abnormality. Cooling fan (FM3) DF control board (DFCB)