Vous êtes sur la page 1sur 6

Visvesvaraya National Institute

of Technology

Analog IC Design Laboratory

ENL-518

Submitted By :
K. Sreehari
MTVD17MVD007
21552
Semester-2
Analog IC Design Laboratory MT17MVD007

Contents
1 Problem statement 2

2 Circuit Parameters 2
2.1 Input Excitation characterstics(applied) . . . . . . . . . . . . . . . . 2
2.2 MOSFET dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3 Simulation Results 3

4 Conclusion 4

List of Figures
1 Frequency Response Curve . . . . . . . . . . . . . . . . . . . . . . . . 5

List of Tables
1 DC Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 AC ANALYSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 NOISE ANALYSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1
Analog IC Design Laboratory MT17MVD007

1 Problem statement
Design a Common Source Amplifier for Gain Greater than 20 dB and Bandwidth
greater than 1 MHZ
Do DC Analysis to show your DC Operating Point using transfer characteristics.
o AC analysis to shown gain and bandwidth(frequency) of your amplifier.
Also Find the input and output noise.

2 Circuit Parameters

2.1 Input Excitation characterstics(applied)

Input type : DC and Voltage 1 : 0V


AC Voltage 2 : 1.8 V
Vdd=1.8 V

2.2 MOSFET dimensions


PMOS NMOS
L : 180nm L : 180nm
W : 360nm W : 360nm

2
Analog IC Design Laboratory MT17MVD007

3 Simulation Results
To Fix the DC Operating Point
V dd
V out =
2
Find Vg for Vout in DC Transfer Curve and Also Find Id for that Particular Vg in
Id-Vd Curve
We can Find Rd from the Output Equation

V out = V dd − Id ∗ Rd

Gain of the Common Source Amplifier is given by

GainAv = −gm ∗ Rd

W/L Vd(V) Vg(V) Id(uA)

(0.95u/0.18u) 0.9 0.64 5.82

Table 1: DC Analysis
Ac Voltage(mV) Gain(dB) Bandwidth(GHZ)

1 20.3 1

Table 2: AC ANALYSIS

INPUT NOISE(mV/Hz) Output Noise(nV/Hz)

24.7 67

Table 3: NOISE ANALYSIS

3
Analog IC Design Laboratory MT17MVD007

4 Conclusion
1. DC Operating point is decided by Vd vs Vg curve where Vd is half of its maxi-
mum value.
2. At that operating point by changing rd value achieved the required gain by track-
ing operating point also.

4
Analog IC Design Laboratory MT17MVD007

1.5
Current (dB)

0.5

DC TRANSFER CURVE
0
0 0.5 1 1.5 2
Voltage ss(Vgs) (Hz)

(a) DC TRANSFER CURVE

20

15
Mag(V(2)/V(1) (dB)

10

-5 GAIN CURVE
1 100 10000 1x106 1x108 1x1010 1x1012
Frequency(Hz)

(b) Gain and Bandwidth Curve

Figure 1: Frequency Response Curve