SINGLE A Outdoor unit (1Ø)

AUUQ18GH2 AUUQ36GH2 / ATUQ36GPLE5


AUUQ24GH2
ATUQ18GQLE5 AVUQ36GKLA2 / ABUQ36GM2A2
ATUQ24GQLE5
ATUQ18GPLE5 APUQ36GRA2 / AUUQ48GH2
ATUQ24GPLE5
Category Functions AVUQ18GJLA2 ATUQ48GMLE5 / AVUQ48GLLA2
AVUQ24GJLA2
ABUQ18GM1A2 ABUQ48GM3A2 / APUQ48GTA2
ABUQ24GM1A2
ABUQ18GL2A1 AUUQ54GH2 / ATUQ54GMLE5
ABUQ24GL3A1
ABUQ18GL2R1 AVUQ54GLLA2 / ABUQ54GM3A2

Defrost / Deicing X X X
High pressure switch X X X
Low pressure switch X X X
Reliability Phase protection X X X
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Test function X X X
Night Silent Operation X X O
Wiring Error Check
Outdoor Units

X X X
Convenience
Peak Control X X X
Mode Lock X X X
Forced Operation (Outdoor Unit) X X X
Network function Network soluation(LGAP) X O O

AUUQ18GH2 AUUQ36GH2 / ATUQ36GPLE5


AUUQ24GH2
ATUQ18GQLE5 AVUQ36GKLA2 / ABUQ36GM2A2
ATUQ24GQLE5
ATUQ18GPLE5 APUQ36GRA2 / AUUQ48GH2
ATUQ24GPLE5
Device AVUQ18GJLA2 ATUQ48GMLE5 / AVUQ48GLLA2
AVUQ24GJLA2
ABUQ18GM1A2 ABUQ48GM3A2 / APUQ48GTA2
ABUQ24GM1A2
ABUQ18GL2A1 AUUQ54GH2 / ATUQ54GMLE5
ABUQ24GL3A1
ABUQ18GL2R1 AVUQ54GLLA2 / ABUQ54GM3A2

AC Ez (Simple Controller) X PQCSZ250S0 PQCSZ250S0


AC Ez Touch X PACEZA000 PACEZA000
AC Smart Ⅳ X PACS4B000 PACS4B000
Central
ACP Ⅳ X PACP4B000 PACP4B000
Controller
AC Manager Ⅳ X PACM4B000 PACM4B000
PI485 X PMNFP14A1 PMNFP14A1
DO(Digital Output) Kit X PQNFP00T0 PQNFP00T0
BNU(Building LONWORKS Gateway X PLNWKB000 PLNWKB000
Network Unit) BACnet Gateway X PQNFB17C0 PQNFB17C0
Y branch X X X
Installation Header branch X X X
Air Guide X X X
PDI(power distribution indicator) X X X
ODU Dry Contact X X X
Low Ambient Kit O (Logical operation) O (Logical operation) O (Logical operation)
Note :
• O: Applied, • X: Not applied
• Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.

2 _ Cooling Only R410A(50/60Hz)


1. SINGLE A Outdoor unit (1Ø)
AUUQ48GH2 AUUQ48GH2 AUUQ48GH2
Outdoor unit
Combination AVUQ48GLLA2 ABUQ48GM3A2 APUQ48GTA2
Indoor unit AVNQ48GLLA2 ABNQ48GM3A2 APNQ48GTA2
Min.~Rated~Max. kW 3.5 ~ 13.4 ~ 13.9 3.6 ~ 13.4 ~ 14.5 3.4 ~ 13.4 ~ 13.7
Cooling
Min.~Rated~Max. Btu/h 11,880 ~ 45,720 ~ 47,500 12,360 ~ 45,720 ~ 49,430 11,720 ~ 45,720 ~ 46,890
Capacity
Min.~Rated~Max. kW - - -
Heating
Min.~Rated~Max. Btu/h - - -
Cooling Rated kW 4.42 4.42 4.42
Power Input
Heating Rated kW - - -
Running Cooling Rated/Max. A 19.2 / 29.0 19.2 / 29.0 19.2 / 29.0
Current Heating Rated/Max. A - - -
EER / COP W/W 3.03 3.03 3.03
SEER / SCOP Btu/W·h 16 16 16

AUUQ54GH2 AUUQ54GH2 AUUQ54GH2


Outdoor unit
Outdoor Units

Combination ATUQ54GMLE5 AVUQ54GLLA2 ABUQ54GM3A2


Indoor unit ATNQ54GMLE5 AVNQ54GLLA2 ABNQ54GM3A2
Min.~Rated~Max. kW 4.5 ~ 15.8 ~ 18.1 4.5 ~ 15.8 ~ 18.1 4.6 ~ 15.8 ~ 18.6
Cooling
Min.~Rated~Max. Btu/h 15,400 ~ 53,910 ~ 61,610 15,400 ~ 53,910 ~ 61,610 15,860 ~ 53,910 ~ 63,420
Capacity
Min.~Rated~Max. kW - - -
Heating
Min.~Rated~Max. Btu/h - - -
Cooling Rated kW 5.21 5.21 5.21
Power Input
Heating Rated kW - - -
Running Cooling Rated/Max. A 22.7 / 29.0 22.7 / 29.0 22.7 / 29.0
Current Heating Rated/Max. A - - -
EER / COP W/W 3.03 3.03 3.03
SEER / SCOP Btu/W·h 16 16 16

Note :
1. All data are based on the following conditions: 3. Due to our policy of innovation some specifications may be changed
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) without notification.
WBOutdoor 35°C(95°F) DB / 24°C(75.2°F) WB 4. Sound Level Values are measured at Anechoic chamber.
- Piping Length : Interconnected Pipe Length = 7.5m Therefore, these values can be increased owing to ambient conditions
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. during opration.
2. Wiring cable size must comply with the applicable local and national 5. The Cooling/Heating Capacity and Energy Efficiency rating is based
code. on standard tests.
The rating will vary slightly with different nation and in different standard.

8 _ Cooling Only R410A(50/60Hz)


1. SINGLE A Outdoor unit (1Ø)
AUUQ48GH2
AUUQ54GH2
ATUQ48GMLE5
ATUQ54GMLE5
Outdoor unit AVUQ48GLLA2
AVUQ54GLLA2
ABUQ48GM3A2
ABUQ54GM3A2
APUQ48GTA2
220-240, 1, 50 220-240, 1, 50
Power Supply V, Ø, Hz
220, 1, 60 220, 1, 60
Cooling Max. A - -
Starting Current
Heating Max. A - -
Wiring Connections Power Supply Cable (included Earth) No. x mm2 (AWG) 3C x 6 (8) 3C x 6 (8)

Casing Color - Warm Gray Warm Gray


WxHxD mm 950 × 834 × 330 950 × 1,170 × 330
Dimensions
WxHxD inch 37-13/32 x 32-27/32 x 13 37-13/32 x 46-1/16 x 13
Net Weight kg (lbs) 61.5 (135.6) 79.1 (174.4)
Type - Twin Rotary Twin Rotary
Model Model x No. GJT325MAA GPT442MAB

Outdoor Units
Compressor
Motor type - BLDC BLDC
Motor Output W x No. 2,137 x 1 4,000 x 1
Type - R410A R410A
Precharged Amount g (oz) 1,900 (67.0) 2,400 (84.7)
Refrigerant Chargeless-Pipe Length m (ft) 15 (49.2) 15 (49.2)
Additional Charging Volume g/m (oz/ft) 20 (0.22) 20 (0.22)
Control - Electronic Expansion Valve Electronic Expansion Valve
Type - FVC68D FVC68D
Refrigerant Oil
Charged volume cc x No. 950 x 1 1,300 x 1
#1_(Row x Column x Fins per inch) x No. - (3 x 40 x 21) x 1 (3 x 34 x 21) x 1
Heat Exchanger
#2_(Row x Column x Fins per inch) x No. - (3 x 22 x 21) x 1
Type - Propeller Propeller
Fan
Air Flow Rate m3/min x No. 58 x 1 45 x 2
Type BLDC BLDC
Fan Motor
Output W x No. 124.2 x 1 85.4 x 2
Sound Pressure Cooling Rated dB(A) 55 55
Level Heating Rated dB(A) - -
Sound Power Level Cooling Rated dB(A) - -
Piping Liquid Outer Dia. mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8)
Connections Gas Outer Dia. mm(inch) Ø 15.88 (5/8) Ø 19.05 (3/4)
Piping Length Max. m (ft) 50 (164.0) 50 (164.0)
Maximum Height Difference Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98.4) 30 (98.4)
Operation Range Cooling Min. ~ Max. ℃ DB (℉ DB) -5 (23.0) ~ 48 (118.4) -5 (23.0) ~ 48 (118.4)
(Outdoor Temperature) Heating Min. ~ Max. ℃ WB (℉ WB) - -

Note :
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.
4. The Net Weight will vary slightly with Vietnam models.
For more information, please refer to the Weight on Catalog.

Cooling Only R410A(50/60Hz) _ 15


Outdoor Units

18 _ Cooling Only R410A(50/60Hz)

1. SINGLE A Outdoor unit (1Ø)


U4 Chassis

AUUQ36GH1 / AUUQ42GH1 / AUUQ48GH1


ATUQ36GMLE3 / ATUQ42GMLE3 / ATUQ48GMLE3
AVUQ36GKLA0 / AVUQ42GLLA0 / AVUQ48GLLA0
ABUQ36GGLA0 / ABUQ42GRLA0 / ABUQ48GRLA0
AUUQ24GS0 / AUUQ36GH2 / ATUQ36GPLE5
AVUQ36GKLA2 / ABUQ36GM2A2 / APUQ36GRA2
AUUQ48GH2 / ATUQ48GMLE5 / AVUQ48GLLA2
ABUQ48GM3A2 / APUQ48GTA2
1. SINGLE A Outdoor unit (1Ø)
Unit Power Supply Compressor OFM IFM
Model Type Voltage/Hz Voltage range MCA MFA MSC RLA kW FLA kW FLA
AUUQ18GH1 - -
ATUQ18GPLE3 0.040 0.60
AVUQ18GJLA0 12.45 20 - 9 0.043 1.2 0.060 0.60
ABUQ18GHLA0 0.154 1.00
ABUQ18GL2A0 0.019 0.80
AUUQ21GH1 - -
ATUQ21GPLE3 0.040 0.60
AVUQ21GJLA0 12.45 20 - 9 0.043 1.2 0.060 0.60
ABUQ21GHLA0 0.154 1.00
ABUQ21GL2A0 0.190 0.80
AUUQ24GH1 - -
ATUQ24GNLE3 0.166 0.60
AVUQ24GJLA0 16.20 25 - 12 0.085 1.2 0.060 0.60
ABUQ24GGLA0 0.154 1.50
ABUQ24GL3A0 0.038 1.00
AUUQ36GH1 1 Phase 220-240 / 50 Min. : 198 - -
Outdoor Units

ATUQ36GMLE3 inverter 220 / 60 Max. : 264 0.166 1.00


19.00 30 - 14 0.124 1.5 0.060 0.70
AVUQ36GKLA0
ABUQ36GGLA0 0.154 1.50
AUUQ42GH1 - -
ATUQ42GMLE3 0.136 1.00
24.10 40 - 18 0.124 1.6 0.120 0.90
AVUQ42GLLA0
ABUQ42GRLA0 0.350 2.30
AUUQ48GH1 - -
ATUQ48GMLE3 0.136 1.00
24.10 40 - 18 0.124 1.6 0.120 0.90
AVUQ48GLLA0
ABUQ48GRLA0 0.350 2.30
AUUQ54GH1 - -
ATUQ54GMLE3 0.136 1.00
24.10 40 - 18 0.248 1.6
AVUQ54GLLA0 0.120 0.90
ABUQ54GRLA0 0.370 2.40
AUUQ24GS0 17.75 25 - 13 0.124 1.6 0.136 1.00

Notes :
1. Voltage range 7. RLA is measured during each individual compressor
Voltage supplied to the unit terminals should be within test condition
the minimum and maximum range 8. OFM is measured as the outdoor unit test condition.
2. Maximum allowable voltage unbalance between phase 9. Recommended circuit breaker is ELCB
is 2% (Earth Leakage Circuit Breaker)
3. MCA = (1.25 x Load1) + Load2 + Load3
- Load1 : Rated running current of largest motor MCA : Minimum Circuit Amperes
(compressor or other motor) MFA : Maximum Fuse Ampere
- Load2 : sum of current for all other motors
MSC : Maximum Starting Current
- Load3 : any other load rated 1.0A or more
4. MFA is used to select the circuit breaker and ground RLA : Rated Load Amperes
fault circuit interrupter (earth leakage circuit breaker) OFM : Outdoor Fan Motor
5. MSC means the Max. current during the starting of IFM : Indoor Fan Motor
compressor.
kW : Fan Motor rated output (kW)
6. MSC & RLA are measured as the compressor only test
condition. FLA : Full Load Amperes

52 _ Cooling Only R410A(50/60Hz)