Defrost / Deicing X X X
High pressure switch X X X
Low pressure switch X X X
Reliability Phase protection X X X
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Test function X X X
Night Silent Operation X X O
Wiring Error Check
Outdoor Units
X X X
Convenience
Peak Control X X X
Mode Lock X X X
Forced Operation (Outdoor Unit) X X X
Network function Network soluation(LGAP) X O O
Note :
1. All data are based on the following conditions: 3. Due to our policy of innovation some specifications may be changed
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) without notification.
WBOutdoor 35°C(95°F) DB / 24°C(75.2°F) WB 4. Sound Level Values are measured at Anechoic chamber.
- Piping Length : Interconnected Pipe Length = 7.5m Therefore, these values can be increased owing to ambient conditions
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. during opration.
2. Wiring cable size must comply with the applicable local and national 5. The Cooling/Heating Capacity and Energy Efficiency rating is based
code. on standard tests.
The rating will vary slightly with different nation and in different standard.
Outdoor Units
Compressor
Motor type - BLDC BLDC
Motor Output W x No. 2,137 x 1 4,000 x 1
Type - R410A R410A
Precharged Amount g (oz) 1,900 (67.0) 2,400 (84.7)
Refrigerant Chargeless-Pipe Length m (ft) 15 (49.2) 15 (49.2)
Additional Charging Volume g/m (oz/ft) 20 (0.22) 20 (0.22)
Control - Electronic Expansion Valve Electronic Expansion Valve
Type - FVC68D FVC68D
Refrigerant Oil
Charged volume cc x No. 950 x 1 1,300 x 1
#1_(Row x Column x Fins per inch) x No. - (3 x 40 x 21) x 1 (3 x 34 x 21) x 1
Heat Exchanger
#2_(Row x Column x Fins per inch) x No. - (3 x 22 x 21) x 1
Type - Propeller Propeller
Fan
Air Flow Rate m3/min x No. 58 x 1 45 x 2
Type BLDC BLDC
Fan Motor
Output W x No. 124.2 x 1 85.4 x 2
Sound Pressure Cooling Rated dB(A) 55 55
Level Heating Rated dB(A) - -
Sound Power Level Cooling Rated dB(A) - -
Piping Liquid Outer Dia. mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8)
Connections Gas Outer Dia. mm(inch) Ø 15.88 (5/8) Ø 19.05 (3/4)
Piping Length Max. m (ft) 50 (164.0) 50 (164.0)
Maximum Height Difference Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98.4) 30 (98.4)
Operation Range Cooling Min. ~ Max. ℃ DB (℉ DB) -5 (23.0) ~ 48 (118.4) -5 (23.0) ~ 48 (118.4)
(Outdoor Temperature) Heating Min. ~ Max. ℃ WB (℉ WB) - -
Note :
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.
4. The Net Weight will vary slightly with Vietnam models.
For more information, please refer to the Weight on Catalog.
Notes :
1. Voltage range 7. RLA is measured during each individual compressor
Voltage supplied to the unit terminals should be within test condition
the minimum and maximum range 8. OFM is measured as the outdoor unit test condition.
2. Maximum allowable voltage unbalance between phase 9. Recommended circuit breaker is ELCB
is 2% (Earth Leakage Circuit Breaker)
3. MCA = (1.25 x Load1) + Load2 + Load3
- Load1 : Rated running current of largest motor MCA : Minimum Circuit Amperes
(compressor or other motor) MFA : Maximum Fuse Ampere
- Load2 : sum of current for all other motors
MSC : Maximum Starting Current
- Load3 : any other load rated 1.0A or more
4. MFA is used to select the circuit breaker and ground RLA : Rated Load Amperes
fault circuit interrupter (earth leakage circuit breaker) OFM : Outdoor Fan Motor
5. MSC means the Max. current during the starting of IFM : Indoor Fan Motor
compressor.
kW : Fan Motor rated output (kW)
6. MSC & RLA are measured as the compressor only test
condition. FLA : Full Load Amperes