Addendum to Doc.

H0569300D

Addendum to the AE-Ti Heat Pump Installation/Operation Manual


Please refer to the following pages for corrections to document H0569300D.
Please note and apply the following changes to the Installation and Operation Manual included with this document.

Page 6, Table 1, AE-Ti Heat Pump Technical Specification. Replace the table as follows:

MODEL AE1500T AE2000T AE2000T--263 AE2500T AE2500T--263 AE3000T AE3000T--263


VOLTAGE 208-230/60/1 208-230/60/1 208-230/60/3 208-230/60/1 208-230/60/3 208-230/60/1 208-230/60/3
OUTPUT* 73,000 BTUs 103,000 BTUs 118,000 BTUs 135,000 BTUs
COP* 5.6 5.4 5.5 5.6
OUTPUT, STANDARD RATING CONDITIONS** 60,000 BTUs 87,000 BTUs 105,000 BTUs 121,000 BTUs
COP, STANDARD RATING CONDITIONS** 5.4 5.1 5.3 5.1
MINIMUM CIRCUIT AMPACITY 28A 39A 23A 40A 28A 47A 31A
MAX OVER CURRENT PROTECTION*** 50A 70A 40A 70A 50A 80A 50A
HEAT EXCHANGER Titanium
COMPRESSOR 40K Scroll 60K Scroll 68K Scroll 81K Scroll
CABINET ABS
REFRIGERANT 56 Oz, R-22 72 Oz, R-22 104 Oz, R-22 116 Oz, R-22
REFRIGERANT HIGH PRESSURE ALARM 450 PSI (reset to 285 PSI)
REFRIGERANT LOW PRESSURE ALARM 30 PSI (reset to 74 PSI)
LOW WATER FLOW ALARM 30 GPM
MAXIMUM HEIGHT BELOW WATER LEVEL 5 feet below pool level
MINIMUM HEIGHT ABOVE WATER LEVEL 11 feet above pool level
OPTIMAL WATER FLOW 55 GPM
MINIMUM WATER FLOW 30 GPM
MAXIMUM WATER FLOW 125 GPM
AIR FLOW 2060 CFM 4120 CFM
WATER TEMPERATURE DIFFERENTIAL Adjustable between 1°F to 5°F
(DELTA T)

UNION SIZE 2”
WEIGHT 225 LBS 325 LBS
SOUND PRESSURE PER ISO 3471 58.9 dBa
* Test Conditions: 80˚ F Air, 80% RH, 80˚ F Water, Outside the scope of ARI Standard 1160
** Rated in accordance with ARI Standard 1160
*** Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest
standard size breaker. The breaker size must not be smaller than the Minimum Circuit Ampacity value.

Page 8, Add Section 2.2.8 as follows:


2.2.8
In order to meet Florida Building Code Efficiency performance requirements and to deliver the rated performance at
the ARI 1160 Low Ambient Standard rating conditions, it will be necessary to install the heat pump in accordance with
the following table:

Model AE1500T AE2000T AE2500T AE3000T


TXV Setting (Number of Turns Open)* 5.25** 5.25** 5.75 5.25**
Refrigerant Charge (R-22, Oz) 56** 72** 86 116**

* All models have adjustable TXVs


** Factory Set

Pages 14 and 15, Replace Electrical Wiring Diagrams (Figures 8 and 9) with updated diagrams provided on
H0296300C

pages 3 and 4 of this addendum.


Page 2

Page 17, Section 4.3, Bonding, Replace the last sentence of the CAUTION Boxes with the following:
For English: “diameter than 8 ga (In Canada, it shall be not smaller than 6 ga.)”
For French: “d’un diamètre de calibe minimal 8 ga (Au Canada, cela ne devrait pas être inférieur à 6 ga.)”
For Spanish: “de un diámetro no inferior a 8 ga (En Canadá, no será más pequeño de 6 ga.)”

Page 18, Section 4.5.2.1, Configure the AquaLink® RS Control System


Remove the last sentence in parenthesis at the end of step 1 that reads:
“(Resistor is included with the Heat Pump.)”

Please note that the resistor is no longer included with the Heat Pump but can be ordered separately from your local
Jandy service center.

Pages 20 and 21, Sections 5.2.3, 5.2.5, 5.3.2, and 5.3.3


Add the following sentence after the first paragraph in the above sections.
“A Maintain Temp Relay is required (provided) and feature must be enabled.”

Page 23, Table 3, Optimal Water Chemistry Ranges


Replace Table 3 with the following table:
Test Recommended Level
Free Chlorine 1.0 to 3.0 ppm
Bromine 2.0 to 4.0 ppm
pH 7.2 to 7.8
Total Alkalinity (TA) 80 to 120 ppm
Calcium Hardness (CH) 175 to 400 ppm
Cyanuric Acid 50 to 75 ppm
Total Dissolved Solids (TDS) 1000 to 2000 ppm (Excluding dissolved NaCl from Salt
Chlorine Generator)
Copper 0 ppm
* Concentration levels taken from “Basic Pool and Spa Technology” published by APSP (Association of Pool and
Spa Professionals).
Table 3. Optimal Water Chemistry Ranges

Page 29, Section 9.2, Jandy AE-Ti Heat Pump Parts List
Replace existing item 17, Part No. R3002000 with item 17, Part No. R0472700. Delete existing item 22, Part No.
R3002801 and add a new item 22, Part No. R3002802, as shown on page 5 of this addendum and as follows:
17 Universal Union and Buttress Set All R0472700
22 Thermal Expansion Valve, 5 Ton, Adjustable (Not Shown) 2,000, 2500, 3000 R3002802

Page 30, Figure 18, Jandy AE-Ti Heat Pumps Exploded View
Replace Figure 18 with revised artwork provided on page 6 of this addendum.
Page 3

PUMP TIME CLOCK


24 VAC
TRANSFORMER
24~
BL BK

24~ BR
R COMPRESSOR
HEATER
MAINTAIN
Y O TEMP
RELAY

BK O

MODEL 3000
Y Y ONLY
BK BK Y BK Y O BK BK
W
BK

R
FAN L1
RELAY

BK BL BK
L
Y BK MAIN 24~ W
O 2
CONTACTOR GROUND
BL
BL

WATER TEMP

BK

AIR TEMP

COMPRESSOR
CAPACITOR R BK R BK
GR Y BK R
BK
O
BK
BL
R

BR
AE SERIES
BL
R POWER 208 - 230 VAC
Y
FAN O
R
INTERFACE
SINGLE PHASE
BR/W
CAPACITOR R
60 Hz
WIRING DIAGRAM
R
COM
JVA JVA
R W W BL INTAKE RETURN

Y BL W BR BK

FACTORY INSTALLED 208/230 VAC


208/230~

FIELD INSTALLED 208/230 VAC


WATER 208/230~

PRESSURE SWITCH Y BK FACTORY 24 VAC HARNESS


BR/W BR 24~
BK R BL
FACTORY 24 VAC
HIGH LOW 24~

GR
REFRIGERANT REFRIGERANT
FACTORY OPTIONAL 24 VAC
PRESS SWITCH PRESS SWITCH 24~

FACTORY OPTIONAL 208/230 VAC


208/230~

FAN COMPRESSOR

BK - BLACK/NOIR/NEGRO
R22 R22 BL - BLUE/BLEU/AZUL
BR - BROWN/MARRON/MARRON
BR/W - BROWN WITH WHITE TRACE/MARRON
REVERSING VALVE AVEC UNE TRACE DE BLANC/MARRON
(OPTIONAL) Y BLANCO
GR - GREEN/VERT/VERDE
O - ORANGE/ORANGE/ANARANJADO
R - RED/ROUGE//ROJO
W - WHITE/BLANC/BLANCO
HEAT EXCHANGER Y - YELLOW/JAUNE/AMARILLO
USER INTERFACE BL ANODE

H3007200B

Figure 8. AE-Ti Single-Phase Electrical Supply Wiring Diagram


Page 4

PUMP TIME CLOCK


24 VAC
TRANSFORMER
24~
BL BK

R COMPRESSOR
HEATER
Y O
MAINTAIN BR
TEMP
RELAY O

BK
MODEL 3000
Y Y ONLY
BK BK Y BK
W BK BK BK
BK
L1
FAN Y
RELAY R R O L
2
W
BK L
BL Y Y BK BL W 3
O BK
BL MAIN CONTACTOR
BL GROUND
W
Y Y

Y-OUT Y C

WATER TEMP
THREE PHASE
LINE VOLTAGE
MONITOR AIR TEMP

L1 L2 L3
GR Y BK R R BK R BK
BK
BK R W O
BL
R

AE SERIES
BR BL
R POWER
208 - 230 VAC
FAN
Y
O
INTERFACE THREE PHASE
R
CAPACITOR BR/W
R
60 Hz
WIRING DIAGRAM
R
COM
JVA JVA
R W W BL INTAKE RETURN

Y BL W BR BK

FACTORY INSTALLED 208/230 VAC


208/230~

FIELD INSTALLED 208/230 VAC


WATER 208/230~

PRESSURE SWITCH Y BK
FACTORY 24 VAC HARNESS
BR
BR/W 24~
BK R BL
FACTORY 24 VAC
HIGH LOW 24~

GR
REFRIGERANT REFRIGERANT
FACTORY OPTIONAL 24 VAC
PRESS SWITCH PRESS SWITCH 24~

FACTORY OPTIONAL 208/230 VAC


208/230~

FAN COMPRESSOR

BK - BLACK/NOIR/NEGRO
R22 R22 BL - BLUE/BLEU/AZUL
BR - BROWN/MARRON/MARRON
BR/W - BROWN WITH WHITE TRACE/MARRON
AVEC UNE TRACE DE BLANC/MARRON
REVERSING VALVE Y BLANCO
(OPTIONAL) GR - GREEN/VERT/VERDE
O - ORANGE/ORANGE/ANARANJADO
R - RED/ROUGE//ROJO
W - WHITE/BLANC/BLANCO
HEAT EXCHANGER Y - YELLOW/JAUNE/AMARILLO
USER INTERFACE BL ANODE

H3007300B

Figure 9. AE-Ti 3-Phase Electrical Supply Wiring Diagram


Page 5

Section 9. Replacement Parts


9.1 Ordering Information
To order or purchase parts for the AE-Ti model heat pumps, contact your nearest Jandy dealer or distributor. See the Jandy web
site at www.jandy.com for the nearest service center. If you still need help, contact Jandy Customer Service, P.O. Box 6000,
Petaluma, California, 94954, Telephone (707) 776-8200 extension 245.
9.2 Jandy AE-Ti Heat Pumps Parts List
Key No. Description Model No. Order Part No.
1 Top Enclosure, Jacket 1500 R3009700
1 Top Enclosure, Jacket 2000, 2500, 3000 R3009100
2 Service Access Panel All R3000500
3 Control Cover - Smoked All R3000601
4 Fan Motor, 1/6 HP, 208 - 230 VAC 1500 R3000703
4 Fan Motor, 1/2 HP, 208 - 230 VAC 2000, 2500, 3000 R3000701
5 Contactor, 1-Phase All R3000801
5 Contactor, 3-Phase 2000, 2500, 3000 R3000802
6 Transformer, 240V 24VA All R3000901
7 Water Pressure Switch All R3001000
8 Capacitor, Fan Motor, 3/370 MFD 1500 R3001101
8 Capacitor, Fan Motor, 7.5/370 MFD 2000, 2500, 3000 R3001100
9 Capacitor, Compressor, 60/370 1500 R3001204
9 Capacitor, Compressor, 80/370 2000, 2500, 3000 R3001203
10 Controller Assembly, Universal All R3008800
11 Refrigerant HP Switch All R3001400
12 Refrigerant LP Switch All R3001500
12 Refrigerant LP Switch (Heat/Cool) 2500,3000 R3001501
13 Wire Harness Kit (Not Shown) All R3009000
14 Fan Blade Set 1500 R3001701
14 Fan Blade Set 2000, 2500, 3000 R3001700
15 Fan Guard 1500 R3001801
15 Fan Guard 2000, 2500, 3000 R3001800
16 Plumbing Bypass Assembly All R3001900
17 Universal Union and Buttress Set All R0472700
18 Evaporator Coil/Guard 1500 R3002104
18 Evaporator Coil/Guard 2000 R3002101
18 Evaporator Coil/Guard 2500 R3002102
18 Evaporator Coil/Guard 3000 R3002103
19 Heat Exchanger Drain Kit (Not Shown) All R3002200
20 Heat Exchanger Replacement Kit 1500 R3009900
20 Heat Exchanger Replacement Kit 2000, 2500, 3000 R3002300
21 Compressor (40K), 1-Phase 1500 R3009800
21 Compressor (60K), 1-Phase 2000 R3002500
21 Compressor (68K), 1-Phase 2500 R3002600
21 Compressor (81K), 1-Phase 3000 R3002700
21 Compressor (60K), 3-Phase 2000 R3003400
21 Compressor (68K), 3-Phase 2500 R3003500
21 Compressor (81K), 3-Phase 3000 R3003600
22 Thermal Expansion Valve, 2 1/2 Ton (Not Shown) 1500 R3002803
22 Thermal Expansion Valve, 5 Ton, Adjustable (Not Shown) 2,000, 2500, 3000 R3002802
23 Water Temperature Sensor All R3002900
24 3-Phase Monitor (3-Phase Models Only) (Not Shown) 2000, 2500, 3000 R3003000
25 Air Temperature Sensor All R3003100
26 Reversing Valve (Optional, Not Shown) 2500,3000 R3003800
27 Achor Bracket Set (Not Shown) All R3003203
28 Heat Pump Drain Kit (Not Shown) All R3004100
29 Junction Box Cover All R3004600
30 Power Interface PCB All R3009200
31 Fan Relay All R3009300
Page 6

15

25
3

11 12

10
14
OR
RE

A
D

NG
YE
BL

E
LL
IR
UE

W
E

OW

IR
W

4 18
E
IR

W
E

IR
E

These pressure switches are installed in


the refrigerant line near the compressor

20

A 21
29

B
17

5
23
16
6

31

30
9
8
7
DETAIL “B”
DETAIL “A”

Figure 18. Jandy AE-Ti Heat Pumps Exploded View


Page 7

Notes
Page 8

Jandy Pool Products, Inc.


H0296300C

6000 Condor Drive, Moorpark, CA, USA 93021 • 1.707.776.8200 FAX 1.707.763.7785
Litho in USA 2008 © Jandy Pool Products, Inc. 0802

Vous aimerez peut-être aussi