H0569300D
Page 6, Table 1, AE-Ti Heat Pump Technical Specification. Replace the table as follows:
UNION SIZE 2”
WEIGHT 225 LBS 325 LBS
SOUND PRESSURE PER ISO 3471 58.9 dBa
* Test Conditions: 80˚ F Air, 80% RH, 80˚ F Water, Outside the scope of ARI Standard 1160
** Rated in accordance with ARI Standard 1160
*** Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest
standard size breaker. The breaker size must not be smaller than the Minimum Circuit Ampacity value.
Pages 14 and 15, Replace Electrical Wiring Diagrams (Figures 8 and 9) with updated diagrams provided on
H0296300C
Page 17, Section 4.3, Bonding, Replace the last sentence of the CAUTION Boxes with the following:
For English: “diameter than 8 ga (In Canada, it shall be not smaller than 6 ga.)”
For French: “d’un diamètre de calibe minimal 8 ga (Au Canada, cela ne devrait pas être inférieur à 6 ga.)”
For Spanish: “de un diámetro no inferior a 8 ga (En Canadá, no será más pequeño de 6 ga.)”
Please note that the resistor is no longer included with the Heat Pump but can be ordered separately from your local
Jandy service center.
Page 29, Section 9.2, Jandy AE-Ti Heat Pump Parts List
Replace existing item 17, Part No. R3002000 with item 17, Part No. R0472700. Delete existing item 22, Part No.
R3002801 and add a new item 22, Part No. R3002802, as shown on page 5 of this addendum and as follows:
17 Universal Union and Buttress Set All R0472700
22 Thermal Expansion Valve, 5 Ton, Adjustable (Not Shown) 2,000, 2500, 3000 R3002802
Page 30, Figure 18, Jandy AE-Ti Heat Pumps Exploded View
Replace Figure 18 with revised artwork provided on page 6 of this addendum.
Page 3
24~ BR
R COMPRESSOR
HEATER
MAINTAIN
Y O TEMP
RELAY
BK O
MODEL 3000
Y Y ONLY
BK BK Y BK Y O BK BK
W
BK
R
FAN L1
RELAY
BK BL BK
L
Y BK MAIN 24~ W
O 2
CONTACTOR GROUND
BL
BL
WATER TEMP
BK
AIR TEMP
COMPRESSOR
CAPACITOR R BK R BK
GR Y BK R
BK
O
BK
BL
R
BR
AE SERIES
BL
R POWER 208 - 230 VAC
Y
FAN O
R
INTERFACE
SINGLE PHASE
BR/W
CAPACITOR R
60 Hz
WIRING DIAGRAM
R
COM
JVA JVA
R W W BL INTAKE RETURN
Y BL W BR BK
GR
REFRIGERANT REFRIGERANT
FACTORY OPTIONAL 24 VAC
PRESS SWITCH PRESS SWITCH 24~
FAN COMPRESSOR
BK - BLACK/NOIR/NEGRO
R22 R22 BL - BLUE/BLEU/AZUL
BR - BROWN/MARRON/MARRON
BR/W - BROWN WITH WHITE TRACE/MARRON
REVERSING VALVE AVEC UNE TRACE DE BLANC/MARRON
(OPTIONAL) Y BLANCO
GR - GREEN/VERT/VERDE
O - ORANGE/ORANGE/ANARANJADO
R - RED/ROUGE//ROJO
W - WHITE/BLANC/BLANCO
HEAT EXCHANGER Y - YELLOW/JAUNE/AMARILLO
USER INTERFACE BL ANODE
H3007200B
R COMPRESSOR
HEATER
Y O
MAINTAIN BR
TEMP
RELAY O
BK
MODEL 3000
Y Y ONLY
BK BK Y BK
W BK BK BK
BK
L1
FAN Y
RELAY R R O L
2
W
BK L
BL Y Y BK BL W 3
O BK
BL MAIN CONTACTOR
BL GROUND
W
Y Y
Y-OUT Y C
WATER TEMP
THREE PHASE
LINE VOLTAGE
MONITOR AIR TEMP
L1 L2 L3
GR Y BK R R BK R BK
BK
BK R W O
BL
R
AE SERIES
BR BL
R POWER
208 - 230 VAC
FAN
Y
O
INTERFACE THREE PHASE
R
CAPACITOR BR/W
R
60 Hz
WIRING DIAGRAM
R
COM
JVA JVA
R W W BL INTAKE RETURN
Y BL W BR BK
PRESSURE SWITCH Y BK
FACTORY 24 VAC HARNESS
BR
BR/W 24~
BK R BL
FACTORY 24 VAC
HIGH LOW 24~
GR
REFRIGERANT REFRIGERANT
FACTORY OPTIONAL 24 VAC
PRESS SWITCH PRESS SWITCH 24~
FAN COMPRESSOR
BK - BLACK/NOIR/NEGRO
R22 R22 BL - BLUE/BLEU/AZUL
BR - BROWN/MARRON/MARRON
BR/W - BROWN WITH WHITE TRACE/MARRON
AVEC UNE TRACE DE BLANC/MARRON
REVERSING VALVE Y BLANCO
(OPTIONAL) GR - GREEN/VERT/VERDE
O - ORANGE/ORANGE/ANARANJADO
R - RED/ROUGE//ROJO
W - WHITE/BLANC/BLANCO
HEAT EXCHANGER Y - YELLOW/JAUNE/AMARILLO
USER INTERFACE BL ANODE
H3007300B
15
25
3
11 12
10
14
OR
RE
A
D
NG
YE
BL
E
LL
IR
UE
W
E
OW
IR
W
4 18
E
IR
W
E
IR
E
20
A 21
29
B
17
5
23
16
6
31
30
9
8
7
DETAIL “B”
DETAIL “A”
Notes
Page 8
6000 Condor Drive, Moorpark, CA, USA 93021 • 1.707.776.8200 FAX 1.707.763.7785
Litho in USA 2008 © Jandy Pool Products, Inc. 0802