In Section 19 Technical Specification of the Contract Agreemert, it Is stated that 'S + 456 is to be re’evied and
guidance for carrying out work.
‘As per the guidelines for minimum stripping time, as per Indian standard 456 for shear walls are 16 to 24 hour.
(1) Concrete fs done under normal circumstances. (2) Cement used is ordinary part land cement (3) Adequate
curing is done (4) Ambient temperature is not fall below 15 degree
‘As per British Standard Formivork Striking Time is sides of beams, walls and columns (5 9 hours et 16 degree
centigrade and for siab is 4 days with normal Portland cement concrete.
4
No where de-shuttering of slab is allowed for 72 hours and for side walls 9 t0 24 hours.
‘As per Turkish Standard Formwork Striking Time is sides of beams, walls and columns is 3 days and for slab is 4
days with normal Portland cement concrete.
‘Thus no where in any of the standards available for she stripping / striking / de-shuttering, the schedule now
claimed by the-Claimant is suggested.
With full knowledge of the technology the agency themselves have to design the structure and plan
procurement of the requiite number of stuttering material So as to complete within the agreed per'od of 8
months.
®
knowing the technology the Agency has to orocuré the requisite shuttering mate-ials has signed the Contract
agreement with a guarantee of completing the work within the stipulated tine of @ months. Having failed to
procure the requisite sets of shuttering material, thay are raising this well after the completion time and
completion of the work as an afterthought.
AL the start of work the Agency nas brought only one set of shuttering materials for side walls and one set
centering for slao, after achieving 50% progress duc to continuous persuasion ‘rom department he has procured
second set of centering that too on'y for slabs in tatal the entive project in two locations has been completed
with only one ser of shuttering materials for side walls and two sets centering for slab. This is tre main reason for
we hk PER CLAUSE WA.) Cpasg-2) OF 1.5.45 18000, Conk OF
Pierce PLAIN AND REINPPREED ConccneTE , priming PERIOD
BEFOLE STRIKING FORMMORK Sate DE 3 04ys FOR S30FET
FOAM HOKK To B Scaggs wit PROPS KEP RED Mn EOVATELY,