Vous êtes sur la page 1sur 12

42GWC

Hydronic Cassette Fan Coil Units


42GWC
Carrier makes the world a better place to live
by creating a comfortable, productive and
healthy environment regardless of climate.
It is our mission is to be customer’s first choice
for air conditioning, heating and refrigeration
solutions everywhere around the world.

Technical Parameter 4

Operating Limits 4

Water Pressure Drop 4

Dimensions 5

Performance Data 6

Wiring Diagram 9
Great Hall of the People,
Beijing, China

Kremlin, Moscow, Russia

White House, Washington, USA

Imperial Palace, Tokyo, Japan


Model number Nomenclature

4 2 G W C 0 1 0 0 2 0 0 1 T H C

Manufacturer Code
Product Design Version
Unit Packing Method
Optional Equipment
Power Supply
Unit Size
Type
Product Series

No.1, 2
Product Series
42: Fan Coil Unit
No.3, 4, 5
Type
GWC : Hydronic Cassette fan Coil Units
No.6, 7, 8
Unit Size (Cooling Capacity KW / Hr)
003: 2.4 KW / Hr
004: 4.0 KW / Hr
005: 4.7KW / Hr
006: 5.9 KW / Hr
008: 8.3 KW / Hr
010: 11.0 KW / Hr
No.9, 10
Power Supply
02 : 220V - 1PH - 50HZ
No.11
Optional Equipment
A : Standard Units
B: Units Includes valve Package
No.12
Unit Packing Method
0 : Standard Packing
No.13
Product Design Version
3: Third Design Revision
No.14, 15, 16
Manufacturer Code
THC : Shanghai Tonghui Carrier

Air Volume
660~1750m3/h

01
Features

It is a compact unit only 298mm in height. The four suspension brackets of the unit adopt the T shape
opening, it can be installed up and fixed easily.
Four-way air distribution gives individual comfort while for localized control each diffuser may be adjusted or
even shut down completely.
The unique design of centrifugal fan ensures the quiet running of the unit. This thoroughly eliminates the
bothering throttle noise inside the room.
High-performance condensate drain pump encased in a special sound-insulating material removes
condensate quietly and fast.
Return air enters the cassette unit through a large grille, cleaned by an easily removable, washable filter,
and then keep the room air fresh through constant circulation.
The Special design of the diffuser ensures rapid blending of the supply and room air. Conditioned air is
directed along the ceiling then evenly distributed throughout the room.
A Large LCD screen thermostat is optioned.

Motor and Fan


Optimized designed centrifugal fan design for 42GWC
High efficiency
Quite running with anti-vibration pads of motor

Coil
Optimized designed 7 mm coil.
“L” coil design
Lanced fin design

Air return grille and filter


The filter inside the air return grille can be easily removed and washed, And keeps the room air fresh
through constant circulation.
The front panel and frill of the unit are designed with stylish appearance makes it suitable to match various
room decorations.

02
Condensate drain pump
High performance condensate drain pump inbuilt the unit, and
enwrapped with special designed insulation material.
Drain out the condensate water quietly.
Keeps running when the unit standby.
To avoid the leakage of the condensate water, it’s recommended to
install the two- way valve or three-way valve in the water system.

Options

Thermostat

Three-way Electric
control valve

Two-way Electric
control valve

03
Technical Parameter

Model
H
Nominal
M m3/h
Air Volume
L
Cooling Caparity
Heating Capacity
Power Input
Noise
Water Flow L/S

Water Drop
Coil Rows
Connection Diameter
Dimensions, girlle
Dimensions, unit
Weight, grille
Weight, unit

Note: Cooling Conditions: 27°C DB/19°C WB entering air temperature, 7°C entering water and 5°C temperature rise.
Heating Conditions: 20°C entering air temperature, 50°C entering water temperature, the same water flow as the cooling conditions.

Operating Limits

Water Circuit Water Circuit Water Circuit


Maximum water-side pressure Maximum temperature Nominal single-phase vohage
Minimum entering water temperature Maximum temperature Operating voltage limits
Maximum entering water temperature
If the room temperature can go down to 0°C, if is advisable to empty the water circuit to avoid damage caused by ice.

Water Pressure Drop

Water connections and Valve not induded Valve assembly Kit

04
Dimensions

42GWC003-004-005

Drainage Connection

42GWC006-008-010

05
Performance Data

Cooling Capacity

Water Water Entering Air Temperature


in temp
Model Temp Rise

T.H S.H T.H S.H T.H S.H T.H S.H T.H S.H T.H S.H T.H S.H

Capacity Multiplier vs Speed


Med Low
Model
T.H S.H T.H S.H

06
Performance Data

Cooling Capacity

Water Water Entering Air Temperature


in temp
Model Temp Rise

T.H S.H T.H S.H T.H S.H T.H S.H T.H S.H T.H S.H T.H S.H

Capacity Multiplier vs Speed


Med Low
Model
T.H S.H T.H S.H

07
Performance Data

Heating Capacity

Available Temp Water Flow


Difference

Available temperature difference = hot water entering - entering air DB temperator


Maximum operating water temperature 80℃, maximum operating pressure 1.4mpA

08
Wiring diagram

Wiring diagram legend


2-Wire Valve
Factory wiring ① Low speed Cables color
Field wiring ② Medium speed A Brown
Connector ③ High speed B Blue
Terminal on terminals ④ Water valve input C Black
Normally closed contact ⑤ Neutral line G Grey
Normally open contact ⑥ Water valve output (ON) E Red
Capacitor ⑦ Water valve output (OFF) W White
3-Wire Valve FC Fan capacitor ⑧ Water valve com line Y-G Yellow/Green
FS Safety switch float
IFM Fan motor indoor unit Connections
PS Drain pump L Line phase
EV Electric valve (cooling) N Neutral
PCB Relay board
HTR Electric heater Warning:
TB Terminal board Any warranty is declined in case of
field changes of factory wiring and
settings

Note:
The connection sequence does not
represent the physical lay-out.