Vous êtes sur la page 1sur 18

Deployment Rules

for Amplifier in FSP 3000R7 Rel.7.x


The document is referred to as deployment rules.

Scope This document describes the deployment rules for amplifier in the Fiber
Service Platform 3000R7 Release 7.0.1 and higher as they are mandatory
to be observed for laser safety classification reasons.
It is not the intent of this document to provide network design and con-
figuration rules in regards to the usage of amplifier modules in different
networks - especially protected - scenarios. These issues are dealt with in
other documents.

Configurations not in accordance with this document are not covered


Caution by the classification for laser product safety standard issued by
ADVA and must therefore not be deployed without written consent
by ADVA.

If a configuration not in accordance with these deployment rules is


Caution installed without prior written consent by ADVA the classification
for laser product safety standard (laser safety class 1M/ hazard level
class 1M) is invalid. In that case classify the product again at your
responsibility and take appropriate actions.

EDFA types The following EDFA types are supported by FSP 3000R7 Rel.7.0.1 and
available in FSP later. For details on the individual releases in which a given EDFA module
3000R7 Rel.7.1 has been released please refer to the respective release notes.

EDFA-C-S10; The EDFA-x-S10 amplifier is used to amplify the four wavelengths of a sin-
EDFA-L-S10 gle group. It is an uncontrolled amplifier in terms of gain or transients.
Therefore it needs to be encompassed by filter modules to limit the noise
generated by that EDFA. These filter modules can either be group splitter
modules for inline amplifier sites or channel splitter modules trailing a
preamplifier.
It can be used as a booster~, inline~ or preamplifier.
1-R 1-T
Intro.fm

Document Version 1.0 Page 1


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

EDFA-C-S18-GC The EDFA-C-S18-GC amplifier is used to amplify the complete C-band. It


is a gain- and transient controlled amplifier.
It can be used as a booster~, inline~ or preamplifier.
Mon-T

1-R 1-T
GC

EDFA-C-D17-GC; The EDFA-x-D17-GC amplifier is used to amplify the complete C- or L-


EDFA-L-D17-GC band. It is a gain- and transient controlled amplifier.
It can be used as a booster~, inline~ or preamplifier.
Mon-T

1-R 1-T
GC

2-T 2-R

EDFA-C-D20-GC The EDFA-C-D20-GC amplifier is used to amplify the complete C-band. It


is a gain- and transient controlled amplifier.
It can be used as a booster~, inline~ or preamplifier.
Mon-T

1-R 1-T
GC

2-T 2-R

Intro.fm

Page 2 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


Chapter 1
Operating EDFAs in parallel
Some of the EDFA types available for FSP 3000R7 Rel.7.x may be operated
in parallel in a given direction. However there are certain requirements
which have to be met when operating EDFAs in parallel.
In addition to the parallel operation of amplifiers they might be deployed
in series. If the restrictions for the serial deployment of different EDFA
types are observed (as specified later in this document) only the last
EDFAs operating in parallel in front of any multiplexing stage need to be
observed.
The following drawing shows an example of EDFAs being deployed in se-
ries plus EDFAs being deployed in parallel prior to multiplexing stage.

EDFA-C-D17-GC

GC GC
EDFA-C-S18-GC
V
2CLSM
EDFA-C-D20-GC
Last EDFA before
Multiplexing stage

EDFA-L-D17-GC

GC GC

EDFA-L-D17-GC

In the following chapters examples are given for forbidden configura-


tions. These examples are not meant to be exhaustive so any further con-
figuration violating the requirements as given in the respective chapter
must not be deployed as well.

1.1 Operating EDFA-x-S10 in parallel


It is possible to deploy up to 16 EDFA-x-S10 in parallel in one direction.
The following drawing shows an EDFA-x-S10 being deployed in parallel,
e.g. using 4GSM.
Deployment Rules_parallel.fm

Document Version 1.0 Page 3


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

EDFA-x-S10

EDFA-x-S10
4GSM

EDFA-x-S10

EDFA-x-S10

These EDFA support the ALS scheme as implemented in


FSP 3000R7 Rel.7.x and therefore are not turned on all the time.
That way it is possible not to violate the requirements as set by the laser
safety class 1M while operating several EDFA-x-S10 in parallel.
In addition using the EDFA-x-S10 it is possible to build hybrid CWDM/
DWDM systems.
In addition the EDFA-x-S10 must not be operated in parallel with GC type
EDFAs as these EDFAs are turned on constantly and the sum of the output
power of the GC type amplifiers plus the ALS pulses amplified by the EDFA-
x-S10 EDFAs might violate the limits of laser safety class 1M.

EDFA-x-S10

EDFA-x-S10
4GSM

EDFA-x-S10

EDFA-x-S10
2BSM-D

EDFA-x-D17-GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC
GC
Deployment Rules_parallel.fm

Page 4 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


EDFA-x-S10

EDFA-x-S10
4GSM

EDFA-x-S10

EDFA-x-S10
2CLSM

EDFA-x-D17-GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC
GC

No GC-type EDFA must be deployed in parallel with EDFA-x-S10

1.2 Operating EDFA-x-D17-GC in parallel


It is possible to deploy a single EDFA-C-D17-GC and a single EDFA-L-D17-
GC in parallel in one direction.
The following drawing shows an EDFA-x-D17-GC being deployed in paral-
lel.
EDFA-C-D17-GC

GC 2CLSM
EDFA-L-D17-GC

GC

The maximum output power of an EDFA-x-D17-GC is limited by design to


a value which allows the operation of an EDFA-C-D17-GC and an EDFA-L-
D17-GC in parallel and to maintain compliancy to laser safety class 1M re-
quirements.
In addition using the EDFA-C-D17-GC it is possible to build hybrid CWDM/
DWDM systems.
Besides the configurations described above the EDFA-x-D17-GC must not
be operated in parallel with any other EDFA as the resulting output power
might violate the limits of laser safety class 1M.
Deployment Rules_parallel.fm

Besides the examples for forbidden configurations given below the for-
bidden configurations including GC type amplifier as shown in Section 1.1
are to be observed as well.

Document Version 1.0 Page 5


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

EDFA-C-D17-GC

EDFA-C-D17-GC GC 2BSM-D
V
EDFA-C-S18-GC
V
EDFA-C-D20-GC GC

No GC-type EDFA (except EDFA-L-D17_GC) must be deployed in parallel


with EDFA-C-D17-GC

EDFA-L-D17-GC

GC 2CLSM
EDFA-C-S18-GC
V
EDFA-C-D20-GC
GC

No GC-type EDFA (except EDFA-C-D17-GC) must be deployed in parallel


with EDFA-L-D17-GC

1.3 Operating EDFA-C-S18-GC in parallel


The maximum output power of the EDFA-C-S18-GC is limited by design to
a value compliant to laser safety class 1M requirements.
The EDFA-C-S18-GC must not be operated in parallel in one direction with
any other EDFA type.
In addition there must be no other channel besides the C-Band deployed
in parallel (neither un-amplified L-Band nor CWDM) to an EDFA-C-S18-GC
as the resulting output power might violate the limits of laser safety class
1M.
Besides the examples for forbidden configurations given below the for-
bidden configurations including GC type amplifier in Section 1.1 are to be
Deployment Rules_parallel.fm

observed as well.

Page 6 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


EDFA-C-S18-GC

EDFA-C-D17-GC GC 2BSM-D
V
EDFA-C-S18-GC
V
EDFA-C-D20-GC GC

EDFA-C-S18-GC

GC 2CLSM
EDFA-L-D17-GC

GC

No GC-type EDFA must be deployed in parallel with EDFA-C-S18-GC

1.4 Operating EDFA-C-D20-GC in parallel


The maximum output power of the EDFA-C-D20-GC is limited by design to
a value compliant to laser safety class 1M requirements.
The EDFA-C-D20-GC must not be operated in parallel in one direction with
any other EDFA type.
In addition there must be no other channel besides the C-Band deployed
in parallel (neither un-amplified L-Band nor CWDM) to an EDFA-C-D20-GC
as the resulting output power might violate the limits of laser safety class
1M.
Besides the examples for forbidden configurations given below the for-
bidden configurations including GC type amplifier in Section 1.1 are to be
observed as well.
Deployment Rules_parallel.fm

Document Version 1.0 Page 7


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

EDFA-C-D20-GC

EDFA-C-D17-GC
v GC 2BSM-AB
EDFA-C-S18-GC
v
EDFA-C-D20-GC
GC

EDFA-C-D20-GC

GC 2CLSM
EDFA-L-D17-GC

GC

No GC-type EDFA must be deployed in parallel with EDFA-C-D20-GC

1.5 Overview
The following table gives an overview about which EDFAs might be oper-
ated in parallel with each other if the respective requirements are met.
Refer to the chapters above for details on the requirements.

Please be aware that besides the requirements for parallel deployment of


EDFAs as defined in this chapter the requirements as defined in the
chapter regarding serial deployment of EDFAs have to be met as well.

Table 1-1: EDFAs which might be operated in parallel


EDFA-x-S10 EDFA-x-D17-GC EDFA-C-S18-GC EDFA-C-D20-GC
EDFA-x-S10 X -- -- --
EDFA-x-D17-GC -- (X) -- --
EDFA-C-S18-GC -- -- -- --
EDFA-C-D20-GC -- -- -- --

X possible
Deployment Rules_parallel.fm

(X) possible only with additional requirements


-- not possible

Page 8 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


Chapter 2
Operating EDFAs in series
For all configurations which are described in this chapter the require-
ments on parallel operation of EDFAs as specified in the previous chapter
need to be followed as well.
There will be drawings presented in this chapter visualizing the deploy-
ment of EDFAs in series. Please be aware that there might be additional
requirements in regards to network design (e.g. filter required) which are
not part of this document.
The drawings in this chapter only refer to the possibility to cascade EDFAs
in series and will not show any additional elements of the network which
might be necessary.

2.1 Operating EDFA-x-S10 in series


The EDFA-x-S10 can be cascaded with other EDFA-x-S10 in series.
The following drawing shows an EDFA-x-S10 being deployed in series with
another EDFA-x-S10.
EDFA-x-S10

EDFA-x-S10

The EDFA-x-S10 amplifier might be cascaded with GC type amplifiers if all


EDFA-x-S10 amplifier of one direction are preceding the GC type amplifier.
The following drawing shows an EDFA-x-S10 being deployed in series pre-
ceding GC type EDFAs.
Deployment Rules_series.fm

Document Version 1.0 Page 9


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

EDFA-x-S10

GC

EDFA-x-D17-GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC

An EDFA-x-S10 might follow any GC type amplifier in the case that the
EDFA-x-S10 is used as a preamplifier on a group level (4 channels only)
and is followed only by a termination or regeneration of all amplified
channels.
The following drawing shows an EDFA-x-S10 being deployed as preampli-
fier following GC type EDFAs.
EDFA-x-D17-GC
v EDFA-x-S10
4CSM
EDFA-C-S18-GC
v
EDFA-C-D20-GC All channels
terminated/
4GSM regenerated
GC

Besides this application the amplified channels must not be multiplexed


or amplified again.
Therefore an EDFA-x-S10 must not follow any GC type amplifier if the am-
plified signals are not terminated or regenerated as in this case the limits
of laser safety class 1M might be exceeded.

EDFA-x-D17-GC
v EDFA-x-S10
EDFA-C-S18-GC
v
EDFA-C-D20-GC

4GSM 4GSM
GC
Deployment Rules_series.fm

Page 10 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


EDFA-x-S10

EDFA-x-D17-GC GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC

The EDFA-x-S10 must not be deployed following GC type EDFA if amplified


signal is not terminated or regenerated.

2.2 Operating EDFA-x-D17-GC in series


The EDFA-x-D17-GC can be cascaded with any other GC type EDFA in se-
ries.
EDFA-x-D17-GC

GC GC

EDFA-x-D17-GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC

For requirements to cascade the EDFA-x-D17-GC with EDFA-x-S10


amplifier please refer to Section 2.1.

2.3 Operating EDFA-C-S18-GC in series


The EDFA-C-S18-GC can be cascaded with any other GC type EDFA operat-
ing in the C-Band in series.
Deployment Rules_series.fm

Document Version 1.0 Page 11


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

EDFA-C-S18-GC

GC GC

EDFA-C-D17-GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC

For requirements to cascade the EDFA-C-S18-GC with EDFA-C-S10 amplifi-


er please refer to Section 2.1.

2.4 Operation EDFA-C-D20-GC in series


The EDFA-C-D20-GC can be cascaded with any other GC type EDFA operat-
ing in the C-Band in series.
EDFA-C-D20-GC

GC GC

EDFA-C-D17-GC
v
EDFA-C-S18-GC
v
EDFA-C-D20-GC

For requirements to cascade the EDFA-C-D20-GC with EDFA-C-S10 amplifi-


er please refer to Section 2.1.

2.5 Overview
The following table gives an overview about which EDFAs might be oper-
ated in series with each other if the respective requirements are met. Re-
fer to the chapters above for details on the requirements.
The table has to be read in such a way that the EDFAs defined in the left-
most column are the ones preceding the EDFAs in the upper row.
Deployment Rules_series.fm

Page 12 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


Please be aware that besides the requirements for serial deployment of
EDFAs as defined in this chapter the requirements as defined in the
chapter regarding parallel deployment of EDFAs have to be met as well.

Table 2-1: EDFAs which might be operated in series in each other


EDFA-x-S10 EDFA-x-D17-GC EDFA-C-S18-GC EDFA-C-D20-GC
EDFA-x-S10 X X X X
EDFA-x-D17-GC (X) X X X
EDFA-C-S18-GC (X) X X X
EDFA-C-D20-GC (X) X X X

X possible
(X) possible only with additional requirements
Deployment Rules_series.fm

Document Version 1.0 Page 13


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

This page intentionally left blank

Deployment Rules_series.fm

Page 14 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


Chapter 3
Notices and Important Safety Information
Notices:
Copyright © 2007. ADVA AG Optical Networking.
All rights reserved. Hardware and software mentioned in this document includes software devel-
oped by ADVA AG Optical Networking ("ADVA"), the Apache Software Foundation (ht-
tp://www.apache.org), Teodor Danciu (http://jasperreports.sourceforge.net), and/or other open
source software. Some software was created using ORBacus for Java by Object-Oriented Concepts,
Inc.

Trademarks
The terms ADVA and FSP are trademarks or registered trademarks of ADVA in the United States,
Germany and/or other countries. All other company, product, or service nPM/MMes mentioned in
this document may be trademarks or service marks of ADVA or their respective owner.

Patents
The content described in this document may be covered by patents or pending patent applica-
tions of ADVA. The furnishing of this document does not give you any license to these patents.

Disclaimers
The content of this document could include technical inaccuracies or typographical errors, and
is subject to change at any time without notice. Reliance on this content is at the relying party's
sole risk and will not create any liability or obligation for ADVA. Any references in this document
to non-ADVA publications and/or non-ADVA Internet sites are provided for convenience only and
do not in any manner serve as an endorsement of those publications and/or Internet sites. The
materials within those publications and/or Internet sites are not part of the materials for any
ADVA information, product or service, and use of those publications and/or Internet sites is at
your own risk.
THE CONTENT OF THIS DOCUMENT IS PROVIDED ''AS IS'' AND ANY EXPRESSED OR IMPLIED WARRAN-
TIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL ADVA, ITS AFFILI-
ATES, EMPLOYEES, OFFICERS OR ITS SUPPLIERS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDEN-
TAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DPM/MMAGES (INCLUDING, BUT NOT LIMITED TO,
PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSI-
NESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CON-
TRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
OUT OF THE USE OF THIS DOCUMENT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DPM/MMAGE.
THE SPM/MME APPLIES FOR ANY HARDWARE OR SOFTWARE COVERED BY THIS DOCUMENT, UNLESS
A SIGNED AGREEMENT WITH ADVA OR THE APPLICABLE PRODUCT LIABILITY LAW EXPRESSLY
STATES OTHERWISE.
Notes.fm

Document Version 1.0 Page 15


Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

ADVA AG Optical Networking


Headquarters
Campus Martinsried
Fraunhoferstr. 9 A
82152 Martinsried/Muenchen
Germany
Phone: +49 (0)89 89 06 65 0
Fax: +49 (0)89 89 06 65 199
info@advaoptical.com

Important safety information:


This is a Class 1M Laser Product with Hazard Level 1M.

Notes.fm

Page 16 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x


Appendix A
Document Revision History
This appendix lists significant changes (additions, corrections, etc.) made in the separate issues
of this documentation. They reflect the corresponding product release.

Date Version Name Comment


09.03.06 0.1 OB 1st Draft Version
20.03.06 0.2 OB Feedback implemented EDFA-x-S10 as preamlifier after GC type
amplifier added
23.03.06 0.3 OB Feedback inplemented
24.03.06 1.0 OB Release version
NW
Change History.fm

Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x Page 17


Change History

This page intentionally left blank

Change History.fm

Page 18 Deployment Rules for Amplifier in FSP 3000R7 Rel.7.x

Vous aimerez peut-être aussi