Accounting for the Unaccounted

Unmeasured losses in storage tanks, vessels and terminal operations can amount
to millions of dollars if instrumentation isn’t accurate.

By: Michael Robinson, Projects, Solutions and Services Marketing Manager,


Endress+Hauser

In modern tank and terminal facilities, material transfer If the transaction will only happen twice a week with a
operations include a mix of legacy processing systems still ±20 gallon accurate instrument, the unaccounted loss
in use, new technologies installed to improve operations, could be as high as 40 gallons. If this transaction occurs
and tank monitoring software. But some older facilities 1,000 times a week, there could be an unaccounted loss of
have not modernized their operations, and can be losing up to 40,000 gallons. If the product sells for $2.50 per
millions of dollars in unaccounted losses, especially if they gallon, then financially an unaccounted loss of up to
are dispensing more materials to customers than they are $100,000 per week will be possible. On the other hand, if
getting paid for. Conversely, errors can be made in the a ±½ gallon accurate instrument is chosen, then the
other direction, shortchanging and overcharging unaccounted loss can be reduced to 500 gallons, saving up
customers, leading to loss of business and other issues. to $98,745.

Oil and gas companies are familiar with the accuracy The frequency, quantity and cost of product are the
standards imposed by custody transfer regulations, but criteria determining the instrument accuracy that should
older chemical plants may still be working with legacy be deployed to measure the transfer. Whether this is a
control systems and outdated instrumentation that can’t flow, volumetric or weight measurement, the accuracy of
provide the necessary accuracy for accounting purposes. the instrument will have a significant financial impact.

Updating and modernizing tank and terminal systems In most legacy control processes, the instruments were
requires a complete analysis of the measuring selected long ago to provide measurement data to the
instrumentation, the methods used to convert control system. They were usually not chosen based on
measurements to volume, and the accuracy of all the the financial impact the measurements could have on the
techniques involved. An assessment of the current profits and reputation. But this situation can be corrected
situation is the best place to begin the process of by using instruments which fulfill both roles, providing
“accounting for the unaccounted.” The first place to start both precise control of operations and accurate financial
is to evaluate the measuring of the product, whether it is accounting.
an inbound or outbound transaction.

The Measurement

Users first need to assess the accuracy of the


measurement instrument itself to determine if it meets
requirements. A quick example: To loadout 5,000 gallons
of a product, how accurate should a measurement
instrument be to ensure that the customer is getting Figure 1: The signal from a 4-20mA instrument can be converted
5,000 gallons? Will the accuracy need to be within ½ from analog to digital, back to analog, and again to digital as it passes
gallon, 1 gallon or 20 gallons? through various microcomputer-based systems.
resolution in the microprocessor have
enough units of accuracy.

In the example, the system is not


taking advantage of all the resolution
available. The process data of 100%
provides only 100 units of accuracy,
while the control system is capable of
13,107 units of accuracy; hence 1,310
units of accuracy are wasted.

In this case, the control system can


accept an input from a measurement
device that’s accurate to thousandths
of a percent. In theory, the potential
unaccounted volume could be reduced
from 600 gallons to 0.6 gallons, or
Figure 2: A level instrument that can transmit in digital—such as this Endress+Hauser ProServo level 599.4 gallons. If the cost of the
transmitter that sends a digital signal— eliminates all the problems with analog signal conversions. product is $2.50 per gallon, then
unaccounted losses can be reduced to
Accuracy of Unit Conversion Measurement to Signal $1,498.

Let’s consider a tank or storage vessel The next conversion to consider takes Removing the analog signal
being filled or loaded with product. It place from the measurement conversion helps eliminate most
has a capacity of 30,000 gallons, and instrument to the control system. signal conversions. This can be done
the operational control indicates the The control system is almost always a by replacing each level measurement
operator should stop filling when the form of microprocessor-based device, instruments with one that can
vessel gets to 85% of capacity. The so the analog instrument data must transmit the measurement as a
process engineer indicated that an be converted to a digital signal. digital value by using EtherNet/IP or
accuracy of 2% was acceptable for another Fieldbus network and
control purposes, and if the tank First, the measurement data in the protocol (Figure 2).
reached 87% it still would not pose instrument in digital form will get
an overspill risk. So with a 2% converted in a digital to analog (D/A) Conversion to Volume
accurate instrument and the control converter, and then represented as a
mechanism programmed to stop at 4-20 mA signal (Figure 1). This 4-20 Assume the measurement data is in
85%, an unaccountable loss of up to mA signal will then go to an analog the control system as a percentage;
600 gallons could occur. input converter on the control that’s sufficient for operations, but
system’s microprocessor where the not for accounting. How can this unit
In this example, the process data conversion process is reversed, with percentage data now be manipulated
generated is in unit percentage. This the resulting digital value placed into and converted?
is great for filling and emptying the a memory register in the
vessel, but financially it is the wrong microprocessor. Continuing to use a 30,000-gallon
unit of measure. The right unit would vessel as an example, the control
be the actual number of gallons in Most legacy microprocessor systems system can convert percentage into
the vessel, which might require an employ a 16-bit A/D conversion in its gallons. The data can simply be
entirely different measurement architecture, so the 4-20 mA signal is linearized; i.e., 0%-100% times
system. now represented in memory as an 30,000 gallons. If the vessel is a
integer value of 3277-16384, or standard geometrical shape, this will
Using unit percentage, the 13,107 digital units of accuracy. It is work. However, if it is not (and this is
measurement device must to be now up to a control systems engineer most likely the case), then an
configured to the appropriate sensing to convert this digital value stored in equation needs to be generated, with
range, and this range must to be memory to a 0%-100% reading. some vessels requiring complex
scaled to indicate 0%-100%. This algorithms.
type of measurement system is Considerations in this process of
difficult to set up to a high degree of signal conversion include making The process of “volume conversion”
accuracy, and difficult to maintain, as sure the instrument range, the D/A needs to be scrutinized to determine
will be shown in the subsequent conversion resolution of the signal if accuracy can be improved. The first
sections. transmitter, and the A/D conversion consideration is the physical

2
Figure 3: A Coriolis flowmeter, such as this Endress+Hauser Promass 300, can calculate volume and mass flow at the point of measurement.

measurement to physical volume data All these factors need to be Another consideration is the pressure
resolution. Whichever physical considered in determining when and the product exerts on the mechanical
measurement is employed, it must be where the measurement should take structure and shape of the vessel. If
reconciled to actual physical volume place to yield the most accurate the mechanical structure flexes while
using a lookup table. The more reading. For example, will settling holding the product, then volume
physical data points referenced, the times need to be introduced to reduce correction may need to be factored to
more accurate is the volume the effect of mechanical waves, or to account for this condition.
conversion. In some cases only two allow foaming to subside? Will
data points are employed—empty and locating the instrument in a different When an accurate volume
full—with everything between these position yield more accurate measurement has been achieved by
two points an approximated value, measurements? Will the type of level taking all these factors into account,
clearly not suitable for accounting instrument need to be changed? a conversion from volume to mass
purposes. typically needs to occur because most
The next consideration when transactions are based on weight.
The next consideration is converting to volume is the effect
understanding the transfer process temperature can have on the storage A simple upgrade for a process
and its impact on the physical vessel and the product in the vessel. needing accurate mass or volume
properties of the material. The Some materials will expand and measurements is to install a flow
transfer process into storage vessels contract when temperatures rise and instrument that can calculate these
creates waves, which can artificially fall. To achieve higher accuracies of values automatically (Figure 3). This
increase the measurement reading. measurement, temperature eliminates the need to perform
These waves can also introduce air compensation can be employed to manual or computer-based
into the material, and the agitation account for this expansion and calculations.
from the process can create foaming contraction. In some cases, it is useful
of the product. to insulate vessels to reduce the
required volume correction.

3
Another solution for both volume and
mass measurements is to use
specialty tank inventory control
hardware and software (Figure 4) to
perform the required complex tank
and vessel calculations.

Summary

To reduce unaccounted lost revenue


in the inventories and transfers of
products, or to avoid overcharging
customers, several considerations
need to be reviewed, understood and
possibly improved upon:

• The accuracy of the measurement


instrument
• The signal conversion process
Figure 4: Endress+Hauser’s TankVision tank scanners and TankVision Professional software
• Unit conversion to volume
provide level measurements, tank correction tables for innage or ullage, temperature and volume • Unit conversion to mass, weight and
corrections, as well as density tables and mass/weight calculations. currency

Volume to Mass However, as usual there are some An assessment can be made once
considerations that need to be these steps have been evaluated and
Conversion from volume to mass can addressed. First is the temperature the considerations of frequency of
be fairly simple and straightforward, effect. Does the density of the transactions, quantity of transaction,
but not always. Once the density of a product change as the temperature of and cost of product are applied. This
product is known, volume multiplied the product changes? If so, then assessment will reveal where
by density will yield the mass of the referencing a density lookup table upgrades should be made to improve
product. The next step is to multiply will help improve the accuracy of the operations and produce a more
by a weight correction factor— conversion and final measurement. accurate accounting.
typically calculated by taking into And are there other substances in the
account the effect of gravity at material such as sediment or water
atmospheric conditions and adjusting that should not be part of the
for any impact that pressure can have calculated weight? If so, these
on the measured product—to substances must be accounted for.
determine weight.

About the Author

Michael Robinson is National Marketing Manager for Projects, Services and Solutions for Endress+Hauser in the
United States. Michael has served the Industrial Automation market since 1994 when he began work as a
controls engineer for an OEM equipment manufacturer in Southern California after graduating from Cal Poly San
Luis Obispo.