Vous êtes sur la page 1sur 18

Radhadarshna Petropack LLP

Sno Material

1 PV Modules

2 Solar Inverters

3 Mounting Structure

3.1 Walkway

4 AC Distribution (Combiner) Panel Board

5 AC Isolators for Inverter


6 Metering Panel

8 Breaker for Client's panel

9 DC/AC Cables
10 Earthing Cables

11 Earthing Strip & Pit Details

12 Conduits
13 Conduit Bends & Extensions

14 GI Cable Tray With Mounting Attachments

15 Cable Ties

16 Heat Sleeve

17 MC4 Connectors
18 GI Wire

19 GI Screw And Rowal Plug

20 Lugs And Nut Bolt Set

21 Anti Corrosive Paste


22 Eletrical Tape
23 Ferules
24 Foam Sealent
25 Danger Boards & Safety Tags

26 Cleaning system

27 Insulators & Accessories for earth strip

28 LA With Mounting Accessories

29 Inverter Stand

30 ACDB Stand

31 Metering Panel Stand

Commu
Sno Material

1 Weather Sensor

2 Data logger .
3 3G Data Card

4 Comunication Cable

5 RJ Connectors
Radhadarshna Petropack LLP - 450 KWp - DC ( 360 KW - AC ) B

Specification Make / Type

Need Costing With Both Indian as well as


325 Wp foreign makes

60 KW Sungrow

Along The Shed Reputed

Reputed

ACCB shall control the AC power from PCU/inverter and will


have necessary surge arrestors. Panel’s shall be metal clad,
totally enclosed, rigid, floor mounted on stand, air - insulated,
cubical type suitable for operation on three/single phase,
415/230 volts, 50 Hz. All indoor panels will have protection of IP
54 or better. All outdoor panels will have protection of IP65 or
better.
Panels shall be installed with SPDs and shall
TECHNICAL SPECS: be suitable for voltage variation of +/- 10%
01 Nos of ACDB , 3P4W , 700A , 415 V, 50 Hz ACDB Box, Fault and frequency variation of +/- 3%.
level 50KA/1 with
6 nos . of 125 Amps 4P MCCB in Incoming and 700 Amps 4P
MCCB on Outgoing side with OL/ SC/EF protections - Check
meter EM6400NG 0.5 with CT rating 550/5 0.5 CL , CT must
sustain the fault level .

125A, 415V, 50 Hz, 3Ph/4W, 50 KA/1


Indoor type metering cubicle will house 415 V level, Bi-
directional Electronic Energy Meters with Dual Core, 0.5 Class,
15 VA, 3 ring type CTs of 550 / 5 Amp each.
01 Nos Unidirectional Meter as Per Discom approval

MCCB 700 Amp ,50kA, 4P, 415V, 50 Hz, Adj S/C & O/L Settings - Panel modification

Annealed Tinned Flexible Cu Conductor Electron Beam Cross Lapp /Leoni/ Polycab /KEI
linked XLPO 120 Deg C, Sheathed and insulated, 4/6 Sq. mm. 1C

1.1KV ,Copper Conducter XLPE - 4C X 50 sqmm


insulated PVC inner sheathed , armoured and PVC Polycab/ Universal/KEI/ Havells
outersheathed as per IS 7098

1.1KV ,Aluminium Conducter XLPE - 4C X 95 sqmm


insulated PVC inner sheathed , armoured and PVC
outersheathed as per IS 7098

1.1KV ,Aluminium Conducter XLPE - 4C X 300 sqmm.


insulated PVC inner sheathed , armoured and PVC Polycab/ Universal/KEI/ Havells
outersheathed as per IS 7098
1.1KV, Flexible Copper Conducter FR PVC - 1C X 2.5 sqmm.
insulated Unarmoured and Unsheathed Cable as Polycab/ Universal/KEI/ Havells
per IS 694

1.1KV, Flexible Copper Conducter FR PVC - 1C X 16 sqmm


insulated Unarmoured and Unsheathed Cable as Polycab/ Universal/KEI/ Havells
per IS 695

25X3 MM GI Flat, For Structure Earthing- 25 X 3 mm. REPUTED

50X6 MM GI Flat, Equipment And LT Panel Earthing- 50X6 mm REPUTED

25 X 6 MM GI Flat, Hot Dip For LA Earthing - 25 X6 mm REPUTED

M6- 25MM, GI Nut Bolt Washer Set REPUTED

Chemical Earthing Pit As Per IS 3043,


A) 17.2 MM Dia, 3 MTS Cu Coated(250 Microns) Steel Rod, T
Joints For Earth Strip Connection JEFF/ JMV/ SABO
B) Chemical Earthing Backfill Compound, 22.5 Kg
C) Pre Cast Chamber

HDPE Pipe PE-63, PN- 4KG DN32 MM Black TIGER /EQ.

HDPE Pipe PE-63, PN- 4KG DN50 MM Black TIGER /EQ.

HDPE/UPVC, 10KG, 32MM ELBO, GRAY TIGER /EQ.

HDPE/UPVC, 10KG, 32MM T BEND, GRAY TIGER /EQ.


HDPE/UPVC, 10KG, 32MM EXTENSION, GRAY TIGER /EQ.

HDPE/UPVC, 10KG, 50MM ELBO, GRAY TIGER /EQ.

HDPE/UPVC, 10KG, 50MM T BEND, GRAY TIGER /EQ.

HDPE/UPVC, 10KG, 50MM EXTENSION, GRAY TIGER /EQ.

Aluminium Strips(To Be Used As Mounting Clamps) - 18 Gauge Reputed .

GI Anchor Fastners For Wall Mounting - M6 X 75 mm

Hot Dip Galvanised Ladder Type Cable Tray

Hot Dip Galvanised Perforated Cable Tray With Cover

GI Anchor Fastners For Cable Tray - M6 X 75mm

Nut Bolt Washer Set For GI Cable Tray along with hardwares and
accessories .

Nylon Cable Tie, UV Resistant - 250mm

25 MM Width(Black) - MC4 Connection & 70 Sq. mm. Cable

40 MM Width(Black) - 300 sqmm Cable

15A, 1000 Vdc - 4/6 sqmm . ELMEX/ AMPHENOL / MULTICONTACT


GI Wire - 18 Gauge Reputed
Rowal Plug Reputed
GI Screw 1.5 Inch Reputed
Cu, Ring Type - 50 sqmm DOWELL
Cu, Ring Type- 16 sqmm DOWELL
Cu, Ring Type - 2.5 sqmm DOWELL
AL Ring type - 95 sqmm DOWELL
Al, Ring Type- 300 Sqmm DOWELL
For Cable Termination Reputed
R,Y,B,Black,G (Each) Steel Grip
Pre Printed Reputed
Reputed
As In Dwg

Circulation pump with piping arrangement (2 HP Pump - 1ph, Kirloskar / Bharat Bijlee
Starter)

10 Sqmm, 2C, Al, Arm. XLPE Havells / Polycab

Insulators - As per site requirements Reputed .

ESE Type - 70 Mtr Radius Reputed .

As per detailled Design Reputed .

As per detailled Design Reputed .

As per detailled Design Reputed .

Communication BOM
Specification Model No

Irradiation sensor

Ambient temp sensor

Module Temp Sensor

suitable for sensors and plant Sensor data .


Pre Paid/ Post paid Connection with 2 Gb Data

CAT 6, Sheilded Comm. Cable

RJ 45 Connector
360 KW - AC ) BOM

Type Standard Units Qty

IEC 61215, IEC


Poly-Crystalline 61730, IEC 61701, NO'S 1385
IEC 62716

IEC 62109-1, IEC


String Inverter 62109-2, IEC NO'S 6
60068-2 (1,2,14,30)

IS 2062 . SET 360kWp

IS 2062 . SET

Switchgear - L&T /
All switches and the circuit Siemens / ABB/C&S or
breakers, connectors should equivalent.
conform to IEC 60947, part I, Nos. 1
Fabricated as per
II and III/ IS 60947 part I, II customized design.
and III .

Reputed Nos. 6
L&T / Secure / Schneider
(meters); 1
Switchgear - L&T / Nos.
Siemens / ABB/C&S or
equivalent (Breakers)

Switchgear - L&T /
Siemens / ABB/C&S or
equivalent. Nos. 1
Fabricated as per
customized design.

Black Colour Outer Covering MTS 6500

MTS 20

Black Colour Outer


Covering(R,Y,B For Phase 250
Conductor)

IEC 60227/ IS 694,


IEC 60502/ IS 1554
IS7098
MTS 150
IS7098

MTS 300

Green Colour

MTS 30

MTS 500

MTS 100

MTS 50

NO'S 500

IS 3043 NO'S 10

MTS 1000

IS:4984:95
MTS 250

NO'S 300

NO'S 300

ASTM-D-1785-SCH-25

ISI
NO'S 100
ASTM-D-1785-SCH-25

ISI
NO'S 150

NO'S 50

NO'S 50

MTS 400

NO'S 800

For Final cable 150 mm Mts 100


Ladder type tray

100 mm for final string Mts 20


terminations

NO'S 1000

NO'S 800

NO'S 3000

MTS 60

MTS 30

PAIRS 300
MTS 500
NO'S 1000
NO'S 1000
NO'S 25
NO'S 15
NO'S 3000
NO'S 50
NO'S 50
Tube 5
Set 10
Set 20
Pcs 10
IS 2551 Set 2

NO'S As required

Mtrs 200

NO'S 500

NO'S 1

NO'S 6

NO'S 1

NO'S 1

Type Standard Units Qty

Voltage / Current based Reputed NO'S 1

PT100 Reputed NO'S 1

PT100 Reputed NO'S 1

Reputed NO'S 1
NO'S 1

D-LINK MTS 500

D-LINK NO'S 20

Vous aimerez peut-être aussi