Vous êtes sur la page 1sur 14

ULTRASITE

O&M
ULTRASITE PREVENTIVE
MAINTENANCE
• Checking the Seals.
• Checking the Temperature Control.
• Lubricating the Door Lock.
• Check Power Supply…..(include BBU)
– External Damages.
– Pressure Spots
– Deformities
– Terminal Corrosion
– Acid Escape
• Running System Test (TRX Loop Test, Power Test)
LED STATUS INDICATION TABLE
Plug-in Switched On Power On and SW Downloading Waiting for Configuration Operational Status
Units or Reset Waiting / Configuration Ongoing
BOI Red – Unit Faulty
Red Yellow Blinking Green Blinking Yellow
Yellow – No LapD Connection
Green – Unit On and Working
Blinking Green – SW
Background Loading
DTRU Red – Unit Faulty, Critical
Blinking Green
Alarm, Incoming Signal Fault
(Later SW Release)
(Abis I/F) or Active Test
disturbing traffic
Yellow – Major or Minor Alarms
or Test Mode
Green – Unit On and Working
Blinking Green – Unit Accessed
DTRU Green – Oudoor Unit TX Signal
Active
RRI LED
Blinking Green – DC Power to
Cable I/F
BB2 Red – Unit Faulty
Red Yellow Blnking Green Blinking Yellow
Yellow – No LapD Connection
Green – Unit On and Working
Blinking Red – Loop Test

TSx Red – Unit Faulty or No BB2


Red Yellow
Connection
Yellow – Unit On, Working, and
not Transmitting (TX Off)
Green – Unit On and Working
Blinking Red – Loop Test
LED STATUS INDICATION TABLE
Plug-in Switched On Power On and SW Downloading Waiting for Configuration Operational Status
Units or Reset Waiting / Configuration Ongoing
BTx

RTx Red – Unit Faulty


Red Blinking Green Blinking Yellow
Blinking Yellow – Tuning
Cavities
Green – Unit On and Working

DVx Red – LNA Faulty


Yellow – Minor LNA Failure
Green – LNA On and Working
PWS Red – Power Supply Alarm
Yellow – Standby or Remote
Control
Green – Unit Switched On and
Working

BATA Red – Unit Faulty


Blinking Yellow
Yellow – Unit Plugged-in but
(Address Switch at
Mains Power is Off or No CCUA
Broadcast, not allowed)
Connection
Green – Unit On and Working

CCUA Red – Unit Faulty


Yellow – Support Cabinet
Alarm, No Q1-SSS Connection
Green – Unit On and Working
Alarm Structure
Equipment View

Equipment
States

Abis Status
Abis Connected
Abis Not Connected

Telecom Status:
Telecom working
Telecom Partially Working
Telecom not Working
BCF States
Symbol State Description
Unknown The state of the BCF is unknown. This state is possible when BTS
Manager is started and the BTS has not yet reported the state of the
BCF.
Autodetecting The BCF enters the 'Autodetecting' state after a reset. The BCF
collects information on the installed units and then sends it to BTS
Manager.
Commissioning The BCF is waiting for commissioning data (Commissioning |
Wizard).
Waiting for LAPD The BCF is waiting for the LAPD establishment. If the BSC is not
connected to the BTS, the BCF remains in this state until the Use
Current command is given from BTS Manager, or until the LAPD
(OMUSIG) is established. If the BSC is connected, the BCF is in
this state until the LAPD link is correctly established.
SW Loading The BCF is loading software from the BSC or BTS Manager. The
BCF determines if SW needs to be loaded from the BSC and loads
it, if necessary. The BCF is in this state also during normal SW
loading with BTS Manager.
The BCF enters this state also after the Disable Abis command is
given with BTS Manager.
Background SW The TRX is in the normal operational state and SW is being loaded
loading on the background.
Configuring The BCF receives the logical (sector) configuration from the BSC.
The BCF also waits for all TRXs to be configured when TRXs load
the DSP SW, initialise RF parts and establish TRXSIGs.
none Supervisory The normal operational state of the BCF.
Blocked The BCF has been blocked with BTS Manager.
TRX States
Symbol State Description
Unknown The state of the TRX is unknown. This state is possible when BTS
Manager is started and the BTS has not yet reported the state of the
TRX.
Waiting for After a reset, the slave TRX is establishing a D-bus connection to the
external input master TRX.
SW loading The TRX sends HW information to the BCF and the runtime DSP
SW of the TRX is loaded. The TRX remains in this state if the BSC
is not connected.
Background SW The TRX is in the normal operational state and SW is being loaded
loading on the background.
Configuring The configuration data is sent from the BCF to the TRXs and the RF
module is initialised. If the BSC is not connected to the BTS or if the
TRX is not in the logical configuration received from the BSC, the
TRX remains in this state.
Waiting for LAPD The TRX is waiting for the LAPD establishment. When the TRXSIG
is detected, the TRX enters the 'Waiting for System Information'
state.If the TRX remains in this state, check that the link settings
(TRXSIG) are correctly allocated.
Waiting for system The TRX is waiting for system information from the BSC.If the TRX
information remains in this state after commissioning request a site unlock from
the BSC or NMS.
none Supervisory The normal operational state of the TRX.
Blocked The TRX has been blocked with BTS Manager.
RTC States
Symbol State Description
Waiting for The unit is waiting for external information
external input
SW loading SW is being loaded to the unit

Configuring The unit is receiving configuration data

none Supervisory The normal operational state of the RTC


Alarm Window
Severity:
Critical/ Major/ Minor Description:
Cause of the alarm State:
Time Enabled/ Disabled
Alarm Code
Event:
Start/ Cancel/ Transient Object:
Unit/ Rack/ Shelf/ Slot
Basic BTS Troubleshooting Procedure
Job ID/ TTR
Analyze Problem
OMC: first aid recovery and Job
Status Acknowledgement

Prepare appropriate
tools and Suspected
Modules if any. OK

On Site: Diagnose Problem Nokia Technical


based on Alarm History in Support available
an organize way.

Not OK Ask assistance from


co-engr.
Replace faulty Technical Problem
modules if necessary. NED and other
useful documents
OK
Commissioning Troubleshooting
Problem Potential Cause Solution

BTS Manager  Failure of BCF to  Update Hwconfiguration


shows auto auto detect the unit. and re-send to BTS.
detected units  RTCx or DVxx  Reconnect cable at
different as defined. cables from designated connector slot.
backplane at wrong
position.
2
 Broken I C bus of  Replace unit.
the unit.
Running TRX Test  TRX cable broken.  Checked TX, RX and DRX
failed (Local and cables.
Remote)  TRX at invalid state.  Change TRX state to
configuring or supervisory.
 Experiencing  Temporarily used dummy
external load instead of antenna and
interference. ( run the test.
receive sensitivity
degraded)
Troubleshooting Power Supply
Problem Potential Cause Solution

 No Power on the  Power supply on  Switch On.


BTS. standby.
 Site Power Supply  Check site Main Power.
Faulty.
 Defective Power Cord.  Replaced Power Cord.
 Cold Start functions  Close the door, to allow
activated. the BTS to warm up
until it reached
operational temp. of –
5C/20F.
 Short in one of the plug-  Pull-out unit one by one
in units. and plug-in one after
another until the power
comes back, to identify
the faulty uint.
Troubleshooting Transmission
• Check LED status and alarm summary.

LED color Steady Flashing


RED Unit faulty, critical alarms, incoming N/A
signal fault (A-bis interface), or active
test interfering with normal traffic.
YELLOW Major and minor alarm or test mode N/A
GREEN Unit is ON and operating N/A

FXC E1/T1