Académique Documents
Professionnel Documents
Culture Documents
Subestación existente
U: 25 kV
Psc: 250 MVA
CMT7...
MVS02
25 kV
Ib8 A
CMT51-98 m
CMT54-42 m
GEN02
160 kVA
Sn: 1 x 200 kVA
TR01 TR03
Sn: 250 kVA Sn: 100 kVA
25 kV / 380 V 25 kV / 220 V
TT TT
CBT45-5 m
CBT53-8 m
CBT47-5 m
CGBT01 CGBT03
160 kVA 35 kVA
Sn: 250 kVA Sn: 100 kVA
CBT64-38 m
CBT49-1 m
CBT65-5 m
TS14 TS15
TS06 25 kVA 13 kVA
109 kVA Sn: 25 kVA Sn: 13 kVA
CBT78-24 m
TS02
CBT76-25 m
CBT74-30 m
CBT73-32 m
CBT72-50 m
CBT71-25 m
CBT70-42 m
53 kVA
CBT55-48 m
CBT63-47 m
CBT62-36 m
CBT60-29 m
CBT61-36 m
CBT59-32 m
CBT58-20 m
CBT57-25 m
CBT56-53 m
Sn: 53 kVA
CBT16-17 m
CBT07-12 m
CBT06-20 m
TS05 TS09
68 kVA 69 kVA
Sn: 68 kVA Sn: 69 kVA
CBT44-15 m
CBT40-36 m
CBT15-9 m
CBT04-20 m
CBT03-19 m
CBT02-30 m
CBT01-19 m
CBT12-32 m
CBT14-25 m
CBT19-25 m
CBT18-22 m
CBT37-46 m
CBT38-23 m
CBT42-31 m
CBT43-20 m
CBT28-13 m
CBT29-17 m
CBT27-9 m
CA_A-1 CA_A-2 CA_A-3 CA_A-4 CA_A-5 CA_G-1 CA_G-2 CA_H-3 CA_H-4 CA_E-2 CA_H-1 CA_H-2
7,9 kVA 7,9 kVA 7,9 kVA 7,9 kVA 7,9 kVA 5,6 kVA 5,6 kVA 6,1 kVA 6,1 kVA 10,4 kVA 6,1 kVA 6,1 kVA
CBT11-17 m
CBT17-13 m
CBT08-14 m
CBT09-27 m
CBT10-37 m
CBT30-10 m
CBT21-11 m
CBT20-10 m
PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85 PF: 0,85