Bulletin 800T/H

30.5 mm Push Buttons


Specifications

Standard Contact Ratings PenTUFF™ (Low Voltage) Contact Ratings


Minimum: 24V, 24 mA Minimum DC: 5V, 1 mA
0 th
Maximum thermal continuous current I 10 A AC/2.5 A DC. Bulletin
Maximum thermal continuous current Ith 2.5 A AC/1.0 A DC. Bulletin
800T units with 800T-XAV contacts have ratings as follows:
800T units with 800T-XA contacts have ratings as follows:
Max. Opertnl. Utilization Category Rated Operational Currents
Max. Opertnl. Utilization Category Rated Operational Currents
Volts Ue IEC NEMA Volts Ue Make Break
Volts Ue IEC NEMA Volts Ue Make Break
1 120…600 7200VA 720VA AC 300 AC-15 C300
120…300
0…120
1800VA
15 A
180VA
1.5 A
AC 600 AC-15 A600 72…120 60 A 720VA
24…150 28VA
24…72 60 A 10 A DC 150 DC-13 R150
0…24 1.0 A
28…600 69VA
DC 600 DC-13 Q600
24…281 2.5 A
2 1 For applications below 24V/24 mA, PenTUFF or Logic Reed contacts are Snap Action Contact Ratings
recommended.
Max. Opertnl. Rated Operational Currents
Contact Rating
Volts Ue Designation Volts Ue Make Break
Sealed Switch Contact Ratings
120…300 7200VA 720VA
AC 300 A300
3 Minimum: 5V, 1 mA 24…72
230…250
60 A
0.2 A
10 A
Maximum continuous current Ith 5 A. Bulletin 800T units have DC 250 —
control circuit ratings with sealed switch contact blocks as follows: 115…125 0.4 A

Max. Opertnl. Utilization Category Rated Operational Currents


MaxDuty Contact Rating
4 Volts Ue IEC NEMA Volts Ue
120…600
Make
3600VA
Break
360VA Maximum thermal continuous current Ith 24 A.
AC 600 AC-15 B600
0…120 30 A 3A Pilot Duty — 120V AC, 12 A; 24V DC, 10 A
24…300 138VA Motor Ratings — 120V AC, 1.5 Hp; 240V AC, 3 Hp; 24V DC,
DC 300 DC-13 P300
0…24 5.0 A 10 A FLA/60 A LRA
5 Time Delay Contacts
Stackable Sealed Switch Contact Ratings
Minimum: 5V, 10 mA (digital); 24V, 1 mA (analog) Max. Opertnl. Rated Operational Currents
Contact Rating
Volts Ue Designation Volts Ue Make Break
Maximum continuous current Ith 2.5 A. Bulletin 800T units have
AC 120 B150 120 3600VA 360VA
6 control circuit ratings with sealed switch contact blocks as follows:
Note: This device is not rated for DC applications.
Max. Opertnl. Utilization Category Rated Operational Currents
Volts Ue IEC NEMA Volts Ue Make Break Adjustment range: 0.5…15 s ± 25% Ith = 5 A
120…300 1800VA 180VA
AC 300 AC-15 C300
0…120 15 A 1.5 A
7 DC 150 DC-13 Q150
24…150 69VA
0…24 2.5 A

Logic Reed Contact Ratings


8 Minimum — DC: 5V, 1 mA
Maximum — DC: 30V, 0.06 A, AC: 150V, 0.15 A
Should only be used with resistive loads.

Materials Used in 800H Type 4X Operators


9 Thermoplastic Polyester (Fiberglass Reinforced)
 Bushings
 Mounting Rings
 Sockets
10 Thermoplastic Polyester
 Non-illuminated button caps

Transparent Amorphous Nylon


11  Pilot light lens cap
 Illuminated button caps

Glass Filled Crystalline Nylon


 Thrust washer
12
Mineral Filled Nylon
 Trim washer

Nitrile (Synthetic Rubber)


13  Gaskets and internal seals

www.ab.com/catalogs Preferred availability cat. nos. are bold.


10-4 Publication A117-CA001A-EN-P

Vous aimerez peut-être aussi