Vous êtes sur la page 1sur 42

Installation Procedure for combination: SP3000 + Frontier model

A) Installation sequence – DICIII >> FMPC >> SP3000

Initial setting for PC (DICIII)


SP3000 FMPC Frontier
Installation of MS01 on DICIII Model

Connection of printer and DICIII


DICIII
HUB

Initial setting for PC (FMPC) Firewire


Ethernet
Firewire Driver install on FMPC

Set bus ID of the Firewire port by VD entry


tool
Installation of MS01

Connect SP3000 to the network and Firewire

Installation of MS11(SP3000)

Installation of MS01(SP3000)

END

B) DICIII PC installation procedure

>>> Initial setting for PC (DICIII)


- set PC name(FRONTEND-DICIII) and Workgroup(WORKGROUP)

- verify computer Date and Time properties

- turn “OFF” Firewall

- set FRONTIER user account with Password

- set IP address(192.168.1.11 is LP default IP address)

- Enable the Hyper Threading feature(depending on PC specification)


Install MS01 into DICIII PC
( For USA market only )
( Un-check it, if not some OS
feature not available for selection)
Remarks : DICIII PC installation completed

C) FMPC installation procedure;


OSInitial
settingsetting
for FMPCfor PC (FMPC)

- set PC name and Workgroup

- verify computer Date and Time properties

- turn “OFF” Firewall

- set FRONTIER user account with password

- set IP address

- Enable Hyper Threading(depending on PC specification)

- do not use Window Found New Hardware function to install Firewire card driver

Remark : Printer is “OFF”, Firewire disconnect


Firewire Driver installation in FMPC

FMPC back view

SP IEEE slot 0

LP IEEE slot 1
( scanner IEEE1394 Firewire card )
Remark : IEEE1394 Firewire card installation for FMPC in case of LP5500/5700/5900
configuration END here.
( Printer “OFF”, Firewire disconnect )
( For USA market only )
N1

Remark : FMPC installation end here

D) SP3000 installation procedure


OS setting in MCU

- confirm IP address

- Change workgroup from MICGROUP to WORKGROUP


( Cancel auto-run for MS01 setup )

Select N:\sp3000 driver\EZ171\setup


( Firewire cable is disconnect from MCU )
>> SP3000 MS01 installation
22 Connect Firewire to the DICIII and Ethernet cable to HUB.

Remark : Whole installation is complete


MS01 installation explanation(up to V2.1)

:
PC to
Types of installation selection Network system configuration
Install

MS01 Server DICIII DICIII system’s software that don’t need to control SP and LP

FMPC Current Frontier model(exclude LP5000/SLP800/1000) is use in


Printer
the network

Scanner MCU in SP1500/2000/3000

MS01 with Printer Support DICIII DICIII need to control LP(LP7###/5000)

MS01 with Scanner support DICIII SP500 is use in the system

MS01 with Scanner and Printer DICIII


SP500 and LP7###/5000 is use
support

MS01 Workstation Client PC All client PC use in the system

DICIII PC
MS01 Workstation with Printer
(2nd Printer Multiple printer system configuration, 2nd printer DICIII PC
support
DICIII PC)

Stand- If don’t need DICIII function in PC, use this installation type to
High Capacity image processor
alone PC setup PC help DICIII server to do rendering of orders

Stand-
MS01 CD burner/PC Rimage CD burner function
alone PC