Académique Documents
Professionnel Documents
Culture Documents
CEI Enterprises
Helical Coil Heaters
Helical Coil Hot Oil Heaters Helical Coil Hot Oil Heaters
Stack Heat
Exchanger
Low Level
Control
General Dimensions and Specifications
(optional) Max. Fuel Usage Heat Transfer
Volume Flow Expansion Tank Fluid Required Length Width Height Pipe Size Approximate
Heater Model Output Btu/hr No.2 (gph) Gas (cfph) Pump Motor HP Rate (gpm) (gallons) (US Gal.) A B C D Weight (lbs)
HCS-350 4,000,000 36 5.200 15 200 400 250 18’-7” 8’-2” 11’-2” 3” 10,700
Full Modulation Coil Inlet
Burner Multi-Circuit Heaters
Circulating
HC-120 1,200,000 11 1,560 10 100 175 95 12’-9” 6’-8” 8’-11” 2” 5,100
Pump Helical HC-200 2,000,000 18 2,600 15 150 280 145 14’-10” 6’-6” 9’-9” 2-1/2” 6,600
Coil
Control Panel
HC-300 3,000,000 27 3,900 15 150 280 165 15’-11” 7’-6” 10’-6” 3” 9,500
HC-400 4,000,000 36 5,200 15 200 400 250 18’-7” 8’-4” 11’-2” 3” 10.900
The amount of fuel used is for a thermal efficiency of 85% and one hour of operation at maximum output. A properly sized heater normally runs for intermittent
Coil Outlet
periods at lower outputs. No. 2 fuel usage is based on 132,000 Btu per gallon, its LHV (low heating value). Natural gas usage is based on 905 Btu per cubic foot,
D its LHV. Heights include the exhaust stack without a stack heat exchanger. The stack heat exchanger for the HCS-350 and HC-400 weighs 800 pounds and adds
HCS-series heater 2’-7” to their height. For all other models it weighs 460 pounds and adds 1’-9” to their height. NOTE: Specifications are subject to change without prior notice
or obligation.
Oil Return
B A
multiple asphalt tanks, and additional components can OPERATION & FEATURES set of serrated finned tubes inside the heat exchanger. is a safety control. It will
Thermal oil flowing inside the tubes is heated before shut down the burner if the
usually benefit from using multiple hot oil circuits.
heat transfer oil reaches the TEMPERATURE CONTROLLERS
HC-series heaters are designed for such applications. Centrifugal Circulating Pump, mounted on the entering the helical coil.
temperature limit set on this & DIGITAL ANNUNCIATOR
They feature a manifold on the output connection that heater skid, circulates heat transfer oil through the heater. This option reduces fuel usage by reducing the output
controller.
Viton shaft seal rings provide a reliable seal with virtually demand placed on the burner. This can reduce fuel
no leakage. consumption by 261 gallons of No.2 fuel oil or 345 therms Flame Monitor
is a microprocessor-based burner
of natural gas per month. A stack heat exchanger usually management control system. The monitor provides
If the heater is equipped with an optional stack heat
pays for itself in one year, or less. proper burner sequencing, ignition and flame monitoring
exchanger, the oil first enters the exchanger, where it is
heated by hot exhaust gases. Oil then exits the stack heat UL-rated, NEMA 4 Control Panel is the nerve
protection. In conjunction with limit and operating controls
it sequences the burner/blower motor, ignition, and fuel
exchanger and enters the helical coil, where it is heated by center of the heater’s temperature control and safety
valves to provide for proper and safe burner operation.
hot gases from the burner. systems. Compliance to UL standards not only assures
Other features include:
Full-Modulation Burner conserves fuel, reduces
you of the quality of the electrical system, it also puts your
insurance company at ease, potentially bringing you lower • Self-diagnostic for safety and reliability.
temperature overshooting and eliminates constant on-off • Non-volatile memory retains information even when
premiums. The NEMA 4 enclosure provides watertight
burner recycling. power is interrupted.
protection against splashing water, hose-directed water,
The burner fires into the open center of the helical coil, rain, sleet, snow, ice, dirt, and windblown dust. • Microprocessor-based for accurate timing,
creating the first pass of hot burner gases. Burner gases comprehensive diagnostics and precision control.
Panels that meet CSA specifications, and other NEMA
HC-SERIES HEATER WITH MANIFOLD FOR MULTIPLE CIRCUITS then turn at the end of the coil, making a second pass
standard enclosures are available optionally.
along the coil’s outer surface.
2 3
Helical Coil Hot Oil Heaters Helical Coil Hot Oil Heaters
HCS-SERIES HEATER FOR SINGLE HOT OIL CIRCUIT. SHOWN WITH OPTIONAL STACK HEAT EXCHANGER.
Digital Annunciator visible on the front of the control Thermal Efficiency: Aside from safety and reliability, Available Options:
panel displays heater status at all times. Any safety limit thermal efficiency is probably the most important aspect • Low-NOx burners (30ppm). Heat Transfer Fluid Specs
that is exceeded will immediately shut down the burner. of any heater. CEI’s helical coil heater approaches the • Ultra low-NOx burners (less than 9ppm). Gravity API 28-30
The cause will be clearly displayed on the LCD screen, theoretical limits of thermal efficiency possible in a fired • Stack heat exchangers for boosting fuel efficiency. The heat transfer oil should be
Flash Point 420° F
paraffin base, solvent refined
reducing down time and assisting CEI Service personnel 2-pass heater. Even without the stack heat exchanger, its • Optional burner management system utilizes an and recommended for operating Viscosity at 100° F 200 SSU
diagnose any heater issues remotely, if necessary. efficiency is 85 percent. exhaust stack O2 sensor to maintain heater operation temperature to 450° F.
Viscosity at 210° F 50 SSU
Wireless Monitoring Systems are optionally Efficiency Gallons / hour Gallons / Month Gallons / Life
in adverse climates. Reduces fuel consumption and
tunes burner automatically.
WARNING: Do not mix paraffin base
oils with aromatic base oils. Mixing
Viscosity Index 95 Min.
First Pass
Second Pass