Operating Data
Capacity . . . . . . . . . . . . . . . . . . Q up to 1080 m3/h (300 l/s
or up to 5000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . H up to 460 m
Temperature of fluid handled . . t up to +50 oC
Speed . . . . . . . . . . . . . . . . . . . . n ≈ 3500 rpm
Supply voltage . . . . . . . . . . . . . U up to 10,000 V
Design
Single-- or multistage centrifugal pumps in pump shroud or in
ring--section design. Radial or mixed flow hydraulic systems;
reduced impeller diameters also available in some cases. The
stage casings of radial pumps are connected by metal straps,
those of mixed flow pumps by stud bolts. Suction casing fitted
between pump and motor. Suction casing equipped with
strainer to protect the pump from coarse particles in the fluid.
Pumps with check valve or connection branch on option.
Available with threaded or flanged end on option.
Particularly suitable for vertical installation in narrow deep wells.
Type series
Minimum well diameter (mm)
(for ex.: 200 mm = 8 inches)
Design status
Capacity (Qopt at 50Hz)
m3/h (4 up to 10 inches) 1)
l/s (12 inches and above)
Number of stages
Reduced impeller diameters Available automation products:
1) UPA 200 -11 + 14: Q in l/s. • Hyamaster
(UPA 200 and UPA 300)
Motor Designation (Example)
UMA 250 D 110 / 2 1 Complete Range
The complete submersible borehole pump range comprises
Type series pump models for capacity up to Q = 2500 m3/h (695 l/s) and
Well diameter (mm) heads up to H = 1500 m.
(for ex. 250 mm = 10 inches) The submersible motor range covers sizes for power ratings up
Design status to P = 3500 kW (4700 hp) and voltages up to U = 10,000 V for
50 and 60 Hz.
Rated power PN for 50 Hz (kW)
In addition, a special range is available which features
Number of poles submersible motors with a higher number of poles.
Winding insulation Certification
Quality management certified to ISO 9001
60 Hz Submersible Borehole Pumps
Contents Page
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
2
60 Hz Submersible Borehole Pumps
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for
use in water with temperatures of up to t = +30 oC. An
indispensable requirement for this is a flow velocity of v = 0.2 m/s
past the motor. This requirement is met, for example, when the
Benefits at a Glance pump is installed in a deep well above the well screen / filter, etc.
With certain restrictions, some motor sizes may also be used
+ Full range of products in water with temperatures of up to t = +50 oC and for operation
+ High-tech equipment without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
+ Optimum material selection
below the screen / filter area or in a pump sump, etc.).
+ Maximum efficiency The details below provide data of adequate accuracy for the
+ Functional reliability allowable temperature as a function of the type of installation,
+ Long service life motor size and flow velocity v past the motor:
+ No maintenance
+ ”Clean” technology Vertical installation:
+ Customer focus -- DN 100 / DN 150:
tallow = tmax1) irrespective of flow past the motor.
-- UMA 150D/200D:
v = 0 m/s . . . . . . tallow ≈ tmax1) -- 5 oC,
v ≥ 0.2 m/s . . . . tallow = tmax1),
v ≥ 0.5 m/s . . . . tallow ≈ tmax1) + 5 oC.
-- UMA 250D:
v = 0 m/s . . . . . . Please consult manufacturer,
v ≥ 0.2 m/s . . . . tallow = tmax1),
v ≥ 0.5 m/s . . . . tallow ≈ tmax1), + 5 oC.
1) Values taken from tables on pages 15, 16 etc., 27, 28 etc..
Horizontal installation:
The principle is the same as for vertical installation.
Exception: Pumps with UMA 250D motors.
These units must always be equipped with a flow inducer
sleeve. The flow inducer sleeve is not required, if the given
pump is equipped with a motor having a 10 % higher power
rating.
For all pump sets:
For a flow velocity of v ≥ 0.5 m/s and horizontal installation,
check back with the manufacturer.
3
60 Hz Submersible Borehole Pumps
" UPZ 1)
BSX, BSF 1)
(≥16 inches)
4
60 Hz Submersible Borehole Pumps
Soft starters electronically reduce the incoming line voltage Effects on submersible borehole pumps
and, hence, the initial starting torque and starting current of
-- Starting current ⇒ approx. 40% to 65% of IA required for
electric motors. During run--up they gently ramp up the applied
voltage to the motor. d.o.l. starting.
In the case of submersible motors, the extremely slim design -- Run-up time tH increased to approx. 1s to 3s compared
and consequential small moments of inertia result in special with approx. 0.2s to 0.5s for direct-starting.
characteristics, which differ strongly from normal asynchro- -- Starting torque MA roughly 1/4 of the direct-starting torque.
nous motors. -- No current or torque peaks (IA, MA), as in star-delta
switching arrangement.
-- Hydraulic pressure surges (waterhammer) upon starting
and stopping of the pump can be reduced, but not fully
eliminated. Therefore, soft starters are not suitable for
solving water hammer problems.
This would require the use of hydraulic control equipment
or a frequency inverter. To prevent effects due to power
failure, additional measures are required.
Note
Conspicuous noise or vibrations during run-up could well be an
indication of incorrect settings on the soft starter. This might be
due to exceeded ramp--up periods, incorrect operating mode
(setting), activated special functions, etc.
120
Run-up Operation Run-down
100
Voltage [%]
80
60
40
20
0
4s 4s
Time [s]
5
60 Hz Submersible Borehole Pumps
In principle, the motors of submersible borehole pumps can Maximum Operating Frequency
also be run on a frequency inverter. As submersible motors Frequency inverter operation above the nominal frequency
differ from conventional standardized motors in terms of (50Hz / 60Hz) of the pump unit must be avoided so as, to
bearings, moment of inertia, insulation, temperature increase, prevent motor overload.
loss distribution and heat distribution, the following parameters
must be observed:
-- Maximum allowable acceleration time (start ramp)
Maximum Permissible Voltage Increase Velocity
-- Maximum allowable deceleration time (stop ramp)
and Peak Voltages
-- Minimum frequency
-- Maximum operating frequency Excessive voltage increase velocities and excessive peak
voltages will reduce the service life of the winding insulation.
-- Maximum permissible voltage increase velocity and peak For this reason, the following limits must be adhered to:
voltages
-- Control principle of frequency inverter -- Maximum voltage increase velocity:
du/dt ≤ 500 V/µs
-- Maximum peak voltages to earth:
Maximum Allowable Acceleration Time (Start Low-voltage motors ≤ 1 kV: J1 insulation ≤ 600 V
Ramp) and Deceleration Time (Stop Ramp) J2 insulation ≤ 800 V
The plain bearings of the submersible motor operation below Note: Compliance with these limits can usually be assured by
the minimum frequency fmin do not tolerate (operation in mixed means of a sine filter or du/dt filter.
lubrication range).
For this reason, the acceleration period from standstill to
minimum frequency fmin should not exceed 2s. The same Control Principle of Frequency Inverter
applies to the deceleration period.
The control principle of the frequency inverter must correspond
to linear U/f curve control. If other control principles are
employed, such as field-oriented inverters, inverters with DTC
or NOF, the manufacturer of the frequency inverter must ensure
Minimum Frequency that the special requirements of submersible motors (very small
moment of inertia, electrical data) are taken into account.
Minimum frequency fmin (Hz)
Vertical Horizontal
Motor size installation installation
DN 100 30
30
DN 150 ----
UMA 150D
UMA 200D
20 30
UMA 250D
UMA 300D /2
UMA 300D /4 30 35
6
60 Hz Submersible Borehole Pumps
Fig. 1 Vertical installation (in deep well, pump sump, etc.) Fig. 3 Horizontal installation (in tanks, mine shafts etc.)
The suspension arrangement of the pump unit must be
designed and dimensioned so that all static and dynamic forces 1 Submersible borehole pump
can be absorbed and that the riser pipe cannot slip downwards. 2 Water storage tanks (UMA 300D and 14D motors only)
The supporting clamps or flanges must be fastened at the well 3 Pedestal
head so that they cannot shift of lift off the well head. 4 Expansion joint
The unit must never be installed with its suction strainer exactly 5 Check valve
at the level of the well screen / filter! Excessive flow in the area (only if pump unit does not have its own check valve)
of the well screen / filter entails the risk of large amounts of 6 Dismantling joint
entrained sand clogging the well screen / filter and causing 7 Shut-off valve
excessive wear in the pump. 8 Intake
Pump units installed in a pump sump must generally be
equipped with a cooling or suction shroud (fig. 2).
7
60 Hz Submersible Borehole Pumps
Pump Selection
The following data are required for a first rough selection of a
submersible borehole pump:
-- Capacity Q in m3/h (l/s)
-- Pressure at well head HA in m
-- Well diameter D in inches or mm
-- Temperature of fluid handled tA in °C
-- Pump head HP in m
While Q, HA, D and tA are usually specified by the customer, the
head HP to be developed by the pump needs to be calculated.
There are two typical applications to be considered (see the
drawing on the right):
Example
Given ...
" QA = 120 m3/h,
" HA = 100 m,
" tA = + 15 °C,
" 50 Hz,
" 400 V,
" d.o.l. starting,
" well diameter D = 300 mm (12 inches),
" Ht = 33 m,
" He = 60 m
Found ...
1. step: pump type UPA 200B/250C
. (for QA taken from selection chart on page 4)
2. step: pump size UPA 250C - 120
. (for QA taken from selection chart on page 50)
3. step: pump set UPA 250C-120/3f + UMA 200D 65/21
. (for Hp = HA + Ht + HV + HS = 100 + 33 + 0.5 + 1.5 = 135 m
. with HV taken from characteristic curves for different stage
. numbers on page 61).
. Pump efficiency: ηP = 81 % (without check valve)
3300:54/3
8
60 Hz Submersible Borehole Pumps
Well depth (distance from ground level to Caution: Do not install the submersible
well base): borehole pump at the level of the well
screen / filter!
TB = . . . . . . . . . . . . . . . . . . . . . . . . . . . . m
8. Control box
5. Total head
(including all friction losses) Manual start-up / remote control /
automatic start-up by way of float switch,
H= ............................ m
pressure switch or dry running protection
F If H is not known, please provide the equipment.
1
following data:
Other types of switchgear: . . . . . . . . . . .
3300:54/3
9
60 Hz Submersible Borehole Pumps
HV HV
m/100 m ft/100 ft
3300:103/3-2
The friction losses given in the above chart roughly apply to new diameter reduced by incrustations. For pipes subject to con-
cast iron pipes. For new rolled steel or plastic pipes, multiply the siderable incrustation, the friction losses can only be deter-
values by approx. 0.8. For old, slightly rusty cast iron pipes, mined experimentally.
multiply by approx. 1.25. In pipes with incrustations, friction Example: Q = 140 m3/h, new DN 150 cast iron pipe.
losses may rise to 1.7 times the value given in the chart for the HV = 3.25 m per 100 m of pipe, v = 2.2 m/sec.
10
60 Hz S 100D
Applications
-- Domestic and general water supply Submersible Borehole Pumps
-- Irrigation and spray irrigation for Well Diameters
-- Lowering groundwater levels of 100 mm (4 inches) and Above
-- Fountains
-- Pressure boosting
-- Air-conditioning systems
-- Fire protection
-- Cooling water cycles
Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 16 m3/h (4 l/s
or up to 60 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 300 m
Temperature of fluid handled . t up to +30 °C
in continuous operation
Power . . . . . . . . . . . . . . . . . . . . . Pn up to 6.4 kW (8.7 hp)
Design
Pump:
Stainless steel and plastic multistage centrifugal pump.
-- Additional bearing depending on the number of stages
-- Pump sizes D1 and D2 with anti-blockage feature. This con-
sists of a hexagonal polyurethane disc mounted to the back
of the diffuser. A PE-HD ring fitted to the impeller front side
sits close to the disc. The impeller hub is protected by a
polyurethane ring.This design improves the starting torque of
low-capacity pumps and has the effect that solid particles such
as sand are propelled outside instead of clogging the pump.
Motor:
Submersible canned motor (Franklin), NEMA standard, 60 Hz
-- For three--phase current
-- With motor lead
-- Connection to power supply mains by means of cable con-
nector (accessories)
-- D.o.l., start-up frequency up to 20 / h
-- Type of enclosure IP 68
-- Thermal class B
Designation
S 100 D -- 4 / 6
Product Features
-- Pumps sizes D1 and D2 with anti-blockage feature
Type series
-- Rust-proof
Well diameter (mm) -- Suitable for installation in narrow deep wells
Design status -- High efficiency
Capacity (m3/h) -- Hermetically sealed motor
-- Motor designed for maximum pump output
Number of stages
-- Low noise level
-- For vertical, angled or horizontal installation
-- Check valve with anti-blockage valve disc
Certification
-- Easy dismantling of check valve
Quality management certified to ISO 9001
11
60 Hz S 100D
S 100D 2
S 100D 1
S 100D 4
S 100D 7
S 100D 12
12
60 Hz S 100D
Materials Drive
Component Execution C1 Type . . . . . . . . . . . . . . . . . . . . . . . canned motor in squirrel-
cage design, 2 poles
Pump ...
Connection . . . . . . . . . . . . . . . . . NEMA standard
Outer pump casing / CrNi steel (1.4301)
Suction casing / Type of enclosure . . . . . . . . . . . IP 68
Valve housing
Frequency . . . . . . . . . . . . . . . . . 60 Hz
Stage casing CrNi steel (1.4301) Type of current . . . . . . . . . . . . . . three-phase (3 µ)
Stage casing (diffuser) / glass fibre reinforced Noryl Rated voltage U . . . . . . . . . . . . . 460 V
Impeller (PPO)
Rated power PN . . . . . . . . . . . . . . . . up to 5.5 kW (7.5 hp)
Shaft Cr steel (1.4021)
Voltage fluctuations . . . . . . . . . . up to ± 5 % acc. to VDE
Bearing bush Nitril NBR 80
Frequency of starts . . . . . . . . . . up to 20 / h
Screws, bolts and nuts CrNiMo steel (A4--70)
Min. delay before restarting . . . . 3 min
Motor ...
Shaft CrNi steel (1.4305)
Bearing carrier CrNi steel (1.4301) Connection to Power Supply
Stator case CrNi steel (1.4301) All DN 100 motors are factory-equipped as follows:
1 x 1.5 m flat cable, quality 4 x 1.5 mm2 (3 phases + 1 earth con-
ductor).
Bearings / Lubrication Exception: DN 100 motors with a rating of 5.5 kW, 3~, are
Plain bearings, lubricated by the fluid pumped or by the motor equipped as follows: 1 x 2.5 m cable, quality 4 x 1.5 mm2.
fill liquid. Depending on the number of stages, an additional in-
Connection of extension cable (any length) by means of a cable
termediate bearing is provided in the pump.
connector:
The axial thrust is balanced by a thrust bearing in the motor.
Connected at the factory by means of a standard cable con-
The hydraulic thrust is balanced by the pump’s counter thrust nector (non-separable, shrink tube)
bearing. -- Ident No. 40 980 708
For cable quality 4 x 1.5 mm2 or 4 x 2.5 mm2
-- Ident No. 39 020 536
Direction of Rotation of the Pump For cable quality 4 x 4 mm2
Clockwise rotation (viewed at the drive shaft end). Connected at the factory with Franklin cable connector
(separable, sealing compound)
-- Ident No. 90 049 385
Pump End (Discharge Nozzle) For cable quality 4 x 1.5 mm2 up to 4 x 2.5 mm2
S 100D - 1, 2, 4 + 7: Internal thread G 11/4” (DN 32).
S 100D - 12: Internal thread G 2’’ (DN 50).
Starting Mode
Only direct on line.
Installation
Vertical and, depending on the number of stages, inclined as
well as horizontal installation (see tables on page 15 to 19) Temperatures
The S 100D submersible borehole pump is designed for use in
water with temperatures of up to t = + 30 oC.
13
60 Hz S 100D
14
60 Hz S 100D
S 100D -- 1
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
Tolerances to
-- Temperature of fluid handled . . . . . up + 30 oC ISO 9906 Class 2
Annex A
-- Current / Operating voltage . . . . . . 3 µ/460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated Rated Current Installation 1)
power power intensity for
(motor) (motor) 3µ
460 V
Pump unit PN PN IN
S 100D kW hp A
1 / 7 0.59 0.80 1.5 v+h
1 / 9 0.83 1.13 2.1 v+h
1 / 12 0.83 1.13 2.1 v+h
1 / 14 1.0 1.36 2.4 v+h
1 / 16 1.0 1.36 2.4 v+h
1 / 20 1.4 1.90 3.1 v+h
1 / 25 1.8 2.45 4.1 v
1 / 30 1.8 2.45 4.1 v
1 / 35 1.8 2.45 4.1 v
1) v = vertical, h = inclined / horizontal.
Capacity
15
60 Hz S 100D
S 100D -- 2
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC Tolerances to
ISO 9906 Class 2
-- Current / Operating voltage . . . . . . 3 µ/460 V Annex A
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated Rated Current Installation 1)
power power intensity for
(motor) (motor) 3µ
460 V
Pump unit PN PN IN
S 100D kW hp A
2 / 7 1.00 1.36 3.4 v+h
2 / 11 1.40 1.90 4.3 v+h
2 / 15 1.80 2.45 5.6 v+h
2 / 18 2.50 3.40 8.6 v+h
2 / 20 2.50 3.40 8.6 v+h
2 / 22 2.50 3.40 8.6 v+h
2 / 27 3.40 4.62 10.6 v
2 / 30 3.40 4.62 10.6 v
2 / 33 4.20 5.71 15.5 v
1) v = vertical and h = inclined / horizontal
Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.
16
60 Hz S 100D
S 100D -- 4
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
Tolerances to
-- Temperature of fluid handled . . . . . up + 30 oC 24 ISO 9906 Class 2
Annex A
-- Current / Operating voltage . . . . . . 3 µ/460 V 21
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated Rated Current Installation 1) 16
power power intensity for
(motor) (motor) 3µ
460 V 11
Pump unit PN PN IN
8
S 100D kW hp A
4 / 3 1.00 1.36 2.4 v+h 6
4 / 6 1.80 2.45 4.1 v+h
4 / 8 2.50 3.40 5.6 v+h
4 / 11 2.50 3.40 5.6 v+h
4 / 16 4.20 5.71 8.7 v+h
4 / 21 4.20 5.71 8.7 v+h 3
Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.
17
60 Hz S 100D
S 100D -- 7
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
Tolerances to
-- Temperature of fluid handled . . . . . up + 30 oC ISO 9906 Class 2
18 Annex A
-- Current / Operating voltage . . . . . . 3 µ/460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated Rated Current Installation 1) 13
power power intensity for
(motor) (motor) 3µ 11
460 V
Pump unit PN PN IN
S 100D kW hp A 8
Capacity
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.
18
60 Hz S 100D
S 100D -- 12
for well diameters of 100 mm (4 inches) and above
Pumps with submersible motors for ...
-- Temperature of fluid handled . . . . . up + 30 oC Tolerances to
ISO 9906 Class 2
-- Current / Operating voltage . . . . . . 3 µ/460 V Annex A
-- Starting . . . . . . . . . . . . . . . . . . . . . . . direct
Rated- Rated- Current Installation 1)
power power intensity for
(motor) (motor) 3µ
460 V
Pump unit PN PN IN
S 100D kW hp A
12 / 4 1.80 2.45 4.1 v+h
12 / 6 3.40 4.62 7.4 v+h
12 / 10 4.20 5.71 8.7 v
12 / 13 6.40 8.70 13.1 v
1) v = vertical, h = inclined / horizontal.
Capacity
19
60 Hz S 100D
20
60 Hz UPA 100C
Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 18 m3/h (5 l/s
or up to 80 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 450 m
Temperature of fluid handled . . t up to +30 °C
Motor ratings . . . . . . . . . . . . . . . PN up to 7.5 kW (10 hp)
Maximum permissible
amount of suspended sand: . . 50 g/m3
Design
Multistage centrifugal pump with components made of stain-
less steel and additional bearing for each stage.
Submersible canned motor: Franklin Electric pre-filled mo-
tors, corrosion free, NEMA shaft end, 60 Hz
-- three-phase motor type Super Stainless
-- with separate lead
-- direct start, max starts : 20 / h
-- Type of enclosure: IP 68
-- Insulation: Class B
Designation
UPA 100 C 10 -- 6
Type series
Minimum well diameter (mm)
Design status
Capacity Qopt (US GPM)
Number of stages
21
60 Hz UPA 100C
UPA 100C 16
UPA 100C 10
UPA 100C 22
UPA 100C 35
UPA 100C 60
UPA 100C 60
Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this range. The operating
ranges ∆QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages.
22
60 Hz UPA 100C
Materials Drive
Type . . . . . . . . . . . . . . . . . . . submersible canned motor
Components Execution C1
Connection . . . . . . . . . . . . . NEMA standard
Pump ...
Type of enclosure . . . . . . . . IP 68
Diffuser,
upper diffuser, Frequency . . . . . . . . . . . . . . 60 Hz
lower diffuser, Type of current . . . . . . . . . . three-phase
Impeller,
Pump shaft with NEMA Rated voltage U . . . . . . . . . 3~ 460 V
coupling, stainless steel AISI 304 Rated power PN . . . . . . . . . up to 7.5 kW (10 hp)
Suction casing,
suction filter, Voltage fluctuations . . . . . . up to +/-- 10 %
Discharge casing, Start-up frequency . . . . . . . up to 20 / h
Spacer sleeve,
Hook Min. standstill time . . . . . . . 3 min
23
60 Hz UPA 100C
Design Features
Reliable in service:
Very strong construction: minimum
Oversized intermediate bearings thickness of stainless sheet steel of
located at each pump stage to 1 mm, 6 spot welding on each vane,
align the shaft, specially designed special top bearing for every pump.
to optimize lubrication.
Friendly service:
Great ease of dismantling and as-
sembly.
Easy-to-replace wear-rings and
Coupling and flange suitable bearings.
for motors with pump mount-
ing dimensions in accor-
dance with NEMA standards.
24
60 Hz UPA 100C
D1
62 UPA 100C 10 -- ...
(Tolerances to ISO 2548
Class C, Annex B)
(3.86 inch) 54
48
41
34
27
(3.75 inch) 21
Ø D1 max:
Pump = 96.5 mm
Pump with motor 15
= 98.0 mm
12
9
6
Rated Rated Rated current
power power for
(Motor) (Motor) 3~
460 V
Pump unit PN PN IN 1)
UPA 100C 10 --.. kW hp A
6 0.37 0.50 1.5
9 0.37 0.50 1.5
12 0.55 0.75 2.1
15 0.75 1.00 2.4
21 1.1 1.50 3.1
27 1.5 2.00 4.1
34 2.2 3.00 5.6
41 3.7 5.00 8.7
48 3.7 5.00 8.7
54 3.7 5.00 8.7 Capacity
62 3.7 5.00 8.7
1) Capacitor run motors (PSC motors) with starter. Operating range: 1.1 -- 3.2 m3/h
(5.0 -- 14.0 US GPM)
Qmin = 1.1 m3/h (5.0 US GPM)
Qmax = End of characteristic curve
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
25
60 Hz UPA 100C
D1
UPA 100C 16 -- ...
62 (Tolerances to ISO 2548
Class C, Annex B)
(3.86 inch)
51
41
31
24
(3.75 inch)
Ø D1 max:
Pump = 96.5 mm 18
Pump with motor
= 98.0 mm 14
10
8
Rated Rated Rated current
power power for 5
(Motor) (Motor) 3~
460 V
Pump unit PN PN IN 1)
UPA 100C 16 --.. kW hp A
5 0.37 0.50 1.5
8 0.55 0.75 2.1
10 0.75 1.00 2.4
14 1.10 1.50 3.1
18 1.50 2.00 4.1
24 2.20 3.00 5.6
31 3.70 5.00 8.7
41 3.70 5.00 8.7
51 5.50 7.50 13.1
62 5.50 7.50 13.1
1) Capacitor run motors (PSC motors) with starter.
Capacity
Operating range: 2.2 -- 4.5 m3/h(10 -- 20 US GPM)
Qmin = 2.2 m3/h (10 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
26
60 Hz UPA 100C
D1
UPA 100C 22 -- ...
60 (Tolerances to ISO 2548
Class C, Annex B)
(3.86 inch)
47
39
31
26
(3.75 inch)
Ø D1 max:
19
Pump = 96,5 mm
Pump with motor
= 98,0 mm
13
10
Rated Rated Rated current 7
power power for
6
(Motor) (Motor) 3~
4
460 V
Pump unit PN PN IN 1)
UPA 100C 22 --.. kW hp A
4 0.37 0.50 1.5
6 0.55 0.75 2.1
7 0.75 1.00 2.4
10 1.10 1.50 3.1
13 1.50 2.00 4.1
19 2.20 3.00 5.6
26 3.70 5.00 8.7
31 3.70 5.00 8.7
39 5.50 7.50 13.1
47 5.50 7.50 13.1
60 7.50 10.0 17.0
1) Capacitor run motors (PSC motors) with starter.
Capacity
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
27
60 Hz UPA 100C
D1
UPA 100C 35 -- ...
(Tolerances to ISO 2548
Class C, Annex B)
(3.86 inch) 41
36
31
26
20
(3.75 inch) 16
Ø D1 max:
Pump = 96,5 mm 12
Pump with motor
= 98,0 mm
9
7
5
Rated Rated Rated current 4
power power for 2
(Motor) (Motor) 3~
460 V
Pump unit PN PN IN 1)
UPA 100C 35 --.. kW hp A
2 0.37 0.50 1.5
4 0.55 0.75 2.1
5 0.75 1.00 2.4
7 1.10 1.50 3.1
9 1.50 2.00 4.1
12 2.20 3.00 5.6
16 3.70 5.00 7.4
20 3.70 5.00 7.4
26 5.50 7.50 13.1
31 5.50 7.50 13.1 Capacity
36 7.50 10.0 17.0
Operating range: 3.3 -- 10 m3/h (15--45 US GPM)
41 7.50 10.0 17.0 Qmin = 3.3 m3/h (15 US GPM)
1) Capacitor run motors (PSC motors) with starter. Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
28
60 Hz UPA 100C
D1
UPA 100C 60 -- ...
(Tolerances to ISO 2548
Class C, Annex B)
(3.86 inch)
18
13
(3.75 inch)
Ø D1 max: 7
Pump = 96,5 mm
Pump with motor
= 98,0 mm 5
4
Rated Rated Rated current
power power for
(Motor) (Motor) 3
3~
460 V
Pump unit PN PN IN 1)
UPA 100C 60 --.. kW hp A
Capacity
Operating range: 5.5 -- 18.0 m3/h (25--80 US GPM)
Qmin = 5.5 m3/h (25 US GPM)
Qmax = End of characteristic curve
The characteristic curves shown are for preliminary selection only.
Exact selection data will be provided in our quotation.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
29
60 Hz UPA 100C
30
60 Hz UPA 150C
Applications
Submersible Borehole Pumps
Suitable for handling clean or slightly contaminated water
in applications such as: for Well Diameters of
-- domestic water supply 150 mm (6 inches)
-- general water supply
-- irrigation and spray irrigation systems
-- artificial lowering of the ground water level as well as
-- heat transfer plants
In addition, the pump sets are used in pressure
boosting systems, air-conditioning systems, fountains, etc.
Permissible sand content in the fluid handled: 50 g/m3.
Operating Data
Capacity . . . . . . . . . . . . . . . . . . Q up to 93 m3/h (26 l/s)
Head . . . . . . . . . . . . . . . . . . . . . H up to 730 m
Temperature of fluid handled . t up to 50 °C
Speed . . . . . . . . . . . . . . . . . . . . n 3500 rpm
Design
Multistage centrifugal pump with components made of
stainless steel and additional bearing for each stage. The stage
casings are connected by means of tie bolts.
Motor
Canned or wet submersible squirrel-cage motor, 2 poles;
NEMA shaft end; 60 Hz; type of enclosure: IP 68
Designation (Example)
UPA 150 C -- 16 / 9
Type series
Minimum well diameter (mm)
Design status
Capacity (m3/h)
Number of stages
Certification
Quality management certified to ISO 9001
Product Features
-- Rust-proof
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical, angled or horizontal installation
-- Check valve with anti-blockage valve disc
31
60 Hz UPA 150C
UPA 150C -- 60
UPA 150C -- 16
UPA 150C -- 30
UPA 150C -- 48
UPA 150C -- 16
32
2
60 Hz UPA 150C
Description
1.4301 CrNi steel Connection to Power Supply
1.4305 CrNi steel The submersible motors are supplied ex factory with 1 or 2
1.4308 CrNi steel motor leads, each equipped with an earth conductor. All motors
are provided with internal earthing. Any extension cables
1.4401 CrNiMo steel
required are connected using water-tight cable connectors.
1.4404 CrNiMo steel Motor leads and extension cables are suitable for drinking
1.4408 CrNiMo steel water applications.
1.4462 CrNiMo steel
1.4571 CrNiMo steel
JL -- 1030 cast iron
A2 CrNi steel
A4 CrNiMo steel
HY22 Carbon/graphite in PTFE
NBR Acrylnitril--Butadien--Kautschuk
33
60 Hz UPA 150C
Starting
Motor DN 100 . . . . . d.o.l. only
(autotransformer or soft starter)
Motor UMA 150D . . d.o.l. (autotransformer or soft starter)
or star-delta
Variable Speed
The submersible borehole pumps can also be equipped with a
speed control system to accommodate different operating
points.
Application Temperatures
The submersible borehole pumps are, as a standard, suitable
for use in water with temperatures of up to t = + 30 °C. An
indispensable requirement for this is a flow velocity of
v = 0.5 m/s past the motor. This requirement is met, for example,
when the pump is installed in a deep well above the well screen
/ filter, etc.
With certain restrictions, some motor sizes may also be used in
water with temperatures of up to t = + 50 °C or for operation
without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).
34
4
60 Hz UPA 150C
Corrosion resistance
The pump and motor are constructed Flexibility
of high--grade stainless steel as D Exchangeable connection variants
standard -- producing consistently D Check valve can be removed easily
high efficiency levels. Also available D Suitable for vertical installation in
in higher grade CrNiMo steel for deep wells or horizontal installation
aggressive fluids. D NEMA connection
35
60 Hz UPA 150C
36
6
60 Hz UPA 150C
37
60 Hz UPA 150C
Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv : Head losses in the check
valve
ηp: Pump efficiency (not
considering check valve)
NPSH: Net positive suction head
required by the pump
Dmax
G 21/2”
Lp
LA
38
8
60 Hz UPA 150C
Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv : Head losses in the check
valve
ηp: Pump efficiency (not
considering check valve)
NPSH: Net positive suction head
required by the pump
Dmax
G 21/2”
Lp
LA
39
60 Hz UPA 150C
Technical Data
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump Motor Motor lead 2), flat
40
0
60 Hz UPA 150C
41
60 Hz UPA 150C
Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv : Head losses in the check
valve
ηp: Pump efficiency (not
considering check valve)
NPSH: Net positive suction head
required by the pump
Pump End G 3”
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall Dmax
length (mm) (mm)
G 21/2” 40
see
G 3” 48
page 45
G 4” 93
DN 50 77 165
DN 65 77 185
DN 80 77 200
Threaded end to DIN ISO 228, Part 1.
Flange end to DIN 2501, Part 1
Dmax
G 3’’
Lp
LA
42
2
60 Hz UPA 150C
Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv : Head losses in the check
valve
ηp: Pump efficiency (not
considering check valve)
NPSH: Net positive suction head
required by the pump
Pump End G 3”
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall Dmax
length (mm) (mm)
G 21/2” 40
see
G 3” 48
page 45
G 4” 93
DN 50 77 165
DN 65 77 185
DN 80 77 200
Threaded end to DIN ISO 228, Part 1.
Flange end to DIN 2501, Part 1
Dmax
G 3’’
Lp
LA
43
60 Hz UPA 150C
Technical Data
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section
head power of the fluid pumped current ciency factor of conductors (use under
Q = 0 m3/h v ≥ 0.5 m/s water, 460 V and ≤ +30 _C)
H0 PN PN tmax 1) IN ηM cos ϕ d.o.l. Y-∆
UPA 150C -- 30 / ... m kW hp _C A % ---- mm2 mm2
1 + DN 100 - 1.5 15.6 1.8 30 4.1 74.0 0.80 4 x 1.5 --
2 + DN 100 - 3.0 31.0 3.4 30 7.4 79.0 0.76 4 x 1.5 --
3 + UMA 150D 5/21 49.0 5.0 43 11.4 75.0 0.77 4 x 2.5 3/4 x 2.5
4 + UMA 150D 5/21 64.0 6.5 39 13.6 75.5 0.83 4 x 2.5 3/4 x 2.5
5 + UMA 150D 7/21 80.0 8.0 38 16.4 77.0 0.82 4 x 2.5 3/4 x 2.5
6 + UMA 150D 7/21 95.0 9.0 33 18.0 76.5 0.84 4 x 2.5 3/4 x 2.5
7 + UMA 150D 9/21 111.0 11.0 33 21.0 78.0 0.84 4 x 2.5 3/4 x 2.5
8 + UMA 150D 13/21 129.0 12.5 39 24.5 82.0 0.79 4 x 2.5 3/4 x 2.5
9 + UMA 150D 13/21 144.0 14.0 37 26.5 82.0 0.81 4 x 2.5 3/4 x 2.5
10 + UMA 150D 13/21 159.0 15.5 34 29.0 81.5 0.83 4 x 2.5 3/4 x 2.5
11 + UMA 150D 15/21 176.0 17.0 36 31.0 82.5 0.84 4 x 4.0 3/4 x 2.5
12 + UMA 150D 15/21 190.0 18.0 33 33.0 82.0 0.84 4 x 4.0 3/4 x 2.5
13 + UMA 150D 18/21 208.0 20.0 34 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5
14 + UMA 150D 18/21 223.0 22.0 32 40.5 82.5 0.83 4 x 4.0 3/4 x 2.5
15 + UMA 150D 22/21 241.0 24.0 37 44.0 84.5 0.81 4 x 4.0 3/4 x 2.5
16 + UMA 150D 22/21 256.0 25.0 36 45.5 84.5 0.82 4 x 4.0 3/4 x 2.5
17 + UMA 150D 22/21 271.0 26.0 34 47.0 84.5 0.83 4 x 4.0 3/4 x 2.5
18 + UMA 150D 26/21 289.0 28.0 38 51.0 85.5 0.82 4 x 6.0 3/4 x 4.0
19 + UMA 150D 26/21 304.0 30.0 37 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0
20 + UMA 150D 26/21 319.0 31.0 36 55.0 85.5 0.84 4 x 6.0 3/4 x 4.0
21 + UMA 150D 30/21 338.0 33.0 38 60.0 86.0 0.81 4 x 6.0 3/4 x 4.0
22 + UMA 150D 30/21 353.0 34.0 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0
23 + UMA 150D 30/21 368.0 36.0 36 64.0 85.5 0.83 4 x 6.0 3/4 x 4.0
1) also see page 34 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.
44
4
60 Hz UPA 150C
45
60 Hz UPA 150C
Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv : Head losses in the check
valve
ηp: Pump efficiency (not
considering check valve)
NPSH: Net positive suction head
required by the pump
Pump End G 3”
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall Dmax
length (mm) (mm)
G 21/2” 40
see
G 3” 48
page 47
G 4” 93
DN 50 77 165
DN 65 77 185
DN 80 77 200
Threaded end to DIN ISO 228, Part 1.
Flange end to DIN 2501, Part 1
Dmax
G 3’’
Lp
LA
46
6
60 Hz UPA 150C
Technical Data
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section
head power of the fluid pumped current ciency factor of conductors (use under
Q = 0 m3/h v ≥ 0.5 m/s water, 460 V and ≤ +30 _C)
H0 PN PN tmax 1) IN ηM cos ϕ d.o.l. Y-∆
UPA 150C -- 48 / ... m kW hp _C A % ---- mm2 mm2
1 + DN 100 - 3.0 19.2 3.4 30 7.4 79.0 0.76 4 x 1.5 --
2 + UMA 150D 5/21 40.0 6.0 41 12.9 75.5 0.81 4 x 2.5 3/4 x 2.5
3 + UMA 150D 7/21 59.0 8.5 36 17.2 77.0 0.83 4 x 2.5 3/4 x 2.5
4 + UMA 150D 9/21 79.0 11.0 33 21.0 78.0 0.84 4 x 2.5 3/4 x 2.5
5 + UMA 150D 13/21 100.0 14.0 37 26.5 82.0 0.81 4 x 2.5 3/4 x 2.5
6 + UMA 150D 15/21 119.0 16.5 36 30.5 82.5 0.83 4 x 4.0 3/4 x 2.5
7 + UMA 150D 18/21 140.0 20.0 35 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5
8 + UMA 150D 18/21 158.0 22.0 31 40.5 82.5 0.83 4 x 4.0 3/4 x 2.5
9 + UMA 150D 22/21 179.0 25.0 36 45.5 84.5 0.82 4 x 4.0 3/4 x 2.5
10 + UMA 150D 26/21 200.0 28.0 38 51.0 85.5 0.82 4 x 6.0 3/4 x 4.0
11 + UMA 150D 26/21 218.0 31.0 36 55.0 85.5 0.84 4 x 6.0 3/4 x 4.0
12 + UMA 150D 30/21 240.0 34.0 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0
13 + UMA 150D 30/21 258.0 36.0 35 64.0 85.5 0.83 4 x 6.0 3/4 x 4.0
14 + UMA 150D 37/22 279.0 40.0 48 72.0 85.0 0.82 3/4 x 4.0 3) 3/4 x 4.0
1) also see page 34 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing. 3) Parallel cable
47
60 Hz UPA 150C
Selection
The pressure losses Hv in the
check valve are not considered in
the pump characteristic curves.
Legend ...
Hv : Head losses in the check
valve
ηp: Pump efficiency (not
considering check valve)
NPSH: Net positive suction head
required by the pump
Pump End G 3”
The information given below is
based on the model with check
valve and threaded end.
The changes in the main
dimensions resulting from different
threaded or flanged ends are
specified in the table below.
Overall Dmax
length (mm) (mm)
G 21/2” 40
see
G 3” 48
page 49
G 4” 93
DN 50 77 165
DN 65 77 185
DN 80 77 200
Threaded end to DIN ISO 228, Part 1.
Flange end to DIN 2501, Part 1
Dmax
G 3’’
Lp
LA
48
8
60 Hz UPA 150C
Technical Data
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 µ) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section
head power of the fluid pumped current ciency factor of conductors (use under
Q = 0 m3/h v ≥ 0.5 m/s water, 460 V and ≤ +30 _C)
H0 PN PN tmax 1) IN ηM cos ϕ d.o.l. Y-∆
UPA 150C -- 60 / ... m kW hp _C A % ---- mm2 mm2
1 + DN 100 - 3.0 19.4 3.4 30 7.4 79.0 0.76 4 x 1.5 --
2 + UMA 150D 5/21 40.0 6.6 37 13.8 75.5 0.83 4 x 2.5 3/4 x 2.5
3 + UMA 150D 9/21 60.0 10.0 36 19.8 78.5 0.83 4 x 2.5 3/4 x 2.5
4 + UMA 150D 13/21 81.0 13.5 38 26.0 82.0 0.81 4 x 2.5 3/4 x 2.5
5 + UMA 150D 15/21 101.0 16.5 36 30.5 82.5 0.83 4 x 4.0 3/4 x 2.5
6 + UMA 150D 18/21 121.0 20.0 34 37.0 83.0 0.82 4 x 4.0 3/4 x 2.5
7 + UMA 150D 22/21 142.0 24.0 37 44.0 84.5 0.81 4 x 4.0 3/4 x 2.5
8 + UMA 150D 22/21 161.0 26.4 34 47.5 84.5 0.83 4 x 4.0 3/4 x 2.5
9 + UMA 150D 26/21 182.0 30.0 37 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0
10 + UMA 150D 30/21 203.0 34.0 37 62.0 86.0 0.82 4 x 6.0 3/4 x 4.0
11 + UMA 150D 37/22 223.0 38.0 50 69.0 85.5 0.81 3/4 x 4.0 3) 3/4 x 4.0
1) also see page 34 2) 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing. 3) Parallel cable
49
60 Hz UPA 150C
50
0
60 Hz UPA 200, 200B, 250C
Applications
Handling clean or slightly contaminated water ... Submersible Borehole Pumps
-- in general water supply systems, for Well Diameters
-- in irrigation and spray irrigation systems, of 200 mm (8 inches) and Above
-- in pressure boosting systems, and of 250 mm (10 inches) and Above
-- in emergency water supply systems,
-- in installations for lowering and maintaining ground water
levels.
Also used in ...
-- mining,
-- sprinkler installations,
-- fountains etc
Permissible sand content in the fluid handled: 50 g/m3.
Also suitable for aggressive seawater if supplied in material
variant C3 (duplex).
Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 400 m3/h (111 l/s
or up to 1600 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 434 m
Temperature of fluid handled . . t up to +50 °C
Speed . . . . . . . . . . . . . . . . . . . . . n ≈ 3500 rpm
Design
Single or multistage, single-entry centrifugal pumps in
ring-section design. Mixed flow hydraulic systems with
impellers that can be turned down. Stage casings connected by
means of studs. Suction casing fitted between pump and motor.
Suction casing equipped with strainer to protect the pump from
coarse particles in the fluid.
Pumps with non-return valve or connection branch on option.
Both models available with either threaded or flanged end.
Particularly suitable for vertical installation in narrow deep
wells.
Designation (Example)
UPA 200 B -- 80 B / 5 d
Type series
Minimum well diameter (mm)
(for ex.: 200 mm = 8 inches) Product Features
Design status -- Very sturdy design
Capacity Qopt for 50 Hz (m3/h) -- Suitable for installation in narrow deep wells
Impeller material1) -- High efficiency
without code letter: execution G
with code B: execution B -- Motor designed for maximum pump output
Number of stages -- Low noise level
Reduced impeller diameters -- For vertical or horizontal installation
1) Applies to UPA 200B only. -- Non-return valve protected against blocking
-- Pre-filled motor; no risk of contamination of the handled
water
Certification
Quality management certified to ISO 9001
51
60 Hz UPA 200, 200B, 250C
UPA 200B -- 80
UPA 200 -- 11
UPA 250C -- 150
UPA 200 -- 14
UPA 250C-120
UPA 200-14 UPA 200B-80
UPA 200-11
UPA 250C-250
UPA 250C-150
UPA 200B-130
Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this range. The operating
ranges ∆QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages.
Selection charts or performance curves for UPA in material variant C3 (duplex) on request only.
52
60 Hz UPA 200, 200B, 250C
Material Variants
Component Execution G Execution B
Casing Cast iron Bronze
(JL1030) 1) (CC480K--GS) 2)
Impeller Glass fibre reinforced NORYL
(PPO)
Diffuser Glass fibre reinforced NORYL
(PPO)
Shaft Cr steel CrNiMo steel
(1.4021) (1.4462)
Wear ring CrNiMo steel (1.4401)
Screws, bolts CrNiMo steel
and nuts (A4-70)
1) DIN mat. code: GG-20 2) DIN mat. code: CuSn10
Bearings / Lubrication
Plain bearing in the end stage, lubricated by the fluid handled.
Axial thrust is balanced by a thrust bearing in the motor.
Part No Description
106/108 Suction casing / Stage casing
143 Suction strainer
171 Diffuser
211 Pump shaft
232 Clockwise impeller
503 Impeller wear ring
529/545 Bearing sleeve / Bearing bush
751 Valve body
849 Sleeve coupling
917 Tie bolt
53
60 Hz UPA 200, 200B, 250C
G B C3 Coating (Standard)
UPA pump (Standard) (Special) (Duplex)
Quality . . . . . . . . . . . 2-component high-build coating
Casing Cast iron Bronze CrNiMo steel (epoxy resin base), approved for drinking
(JL1040) 1) (CC480K-GS) 2) (1.4517) water contact
Im- 200B Glass fibre Bronze
reinforced (CC480K-GS) 5) Coating structure . . Primer and top coat
peller
NORYL CrNiMo steel
(1.4517) Film thickness . . . . 100 to 150 µm
(PPO)
250C Bronze (CC480K-GS) 2) Colour . . . . . . . . . . . ultramarine blue (RAL 5002)
Shaft Cr steel CrNiMo steel
(1.4021) (1.4462)
Wear ring high-performance plastics CrNiMo steel Type of Installation
(1.4538)
In general, the pumps are installed vertically. Some models
Screws, bolts CrNiMo steel CrNiMo steel may also be installed horizontally depending on the number of
and nuts 4) (A4--70) (1.4462)
stages and motor size.
G C2 C3 Drive
UMA motor (Standard) (Special) (Duplex)
Motor type . . . . . . . . water-filled submersible
Shaft 150D CrNi steel CrNiMo steel
squirrel-cage motor, 2 poles
(1.4305) (1.4462)
Type of enclosure . IP 68
200D
CrNiMo steel CrNiMo steel
250D
(1.4462) (1.4462) Frequency . . . . . . . . 60 Hz
300D
Type of current . . . . three-phase (3~)
Hou- 150D Cast iron CrNiMo steel CrNiMo steel
sing
g (JL1030) 3) (1.4409) (1.4539) Rated voltage U . . . 440 V ... 460 V
200D Cast iron CrNiMo steel CrNiMo steel Rated power PN . . . up to 225 kW ( 301.7 hp)
250D (JL1030) 3) (1.4408) (1.4539) Frequency of starts 15/h 1) and 10/h 2)
300D Cast iron CrNiMo steel Minimum delay
(JL1040) 1) (1.4517) before restarting . . 1 min 1) and 3 min 2)
Stator 150D CrNi steel CrNiMo steel CrNiMo steel Motor design is in compliance with VDE regulations.
case (1.4301) (1.4571) (1.4539)
1) Motor UMA 150D
2)
200D CrNiMo steel CrNiMo steel CrNiMo steel Motors UMA 200D and 250D
250D (1.4301) (1.4571) (1.4539)
300D CrNiMo steel CrNiMo steel
(1.4301) (1.4462) Connection to Power Supply
Screws 150D CrNi steel CrNiMo steel CrNiMo steel The motors are normally equipped ex works as follows with
bolts (1.4301) (A4--70) (1.4539) short flat cables ...
and
d
nuts 4) 200D CrNiMo steel CrNiMo steel -- UMA 150D:
250D (A4--70) (1.4539) 1 x 4 m with 4 conductors (3 phases + 1 earth conductor)
300D CrNiMo steel CrNiMo steel for direct starting or
(A4--70) (1.4462) 1 x 4 m with 3 conductors and 1 x 4 m with 4 conductors (3
phases + 1 earth conductor) for direct and star-delta
1) DIN mat. code: GG-25 3) DIN mat. code GG-20 starting,
2) DIN mat. code: CuSn10 4) Wetted by fluid handled
5) for size 80B and 130B -- UMA 200D + UMA 250D:
1 x 6 m with 3 conductors and 1 x 6 m with 4 conductors (3
phases + 1 earth conductor) for direct and star-delta
starting.
Bearings / Lubrication
All motor sizes are equipped with internal earthing.
Radial plain bearings; lubricated by the liquid handled or by the
motor filling water. Depending on the number of stages 1 Connection of extension cable on short cable by means of a
intermediate bearings is fitted on the pump unit. waterproof cable connector (see ”accessories” )
The axial thrust is balanced by a thrust bearing with Short cable and extension cable in food quality.
self-adjusting tilting pads in the lower part of the motor. Note: The cross-section of short cable is only designed for
underwater use. For laying partially or completely in air it is
necessary to check the cross-section of this cable.
Direction of Rotation of the Pump
Clockwise rotation (when looking at the drive shaft end).
54
60 Hz UPA 200, 200B, 250C
Starting
Direct on line (without or with starting transformer as well as
with smooth running device) or star-delta starting.
Variable Speed
The submersible motor pumps can also be adjusted with a
speed adjustment to different duty points.
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for
use in water with temperatures of up to t = +30 °C. An
indispensable requirement for this is a flow velocity of v = 0.5 m/s
past the motor. This requirement is met, for example, when the
pump is installed in a deep well above the well screen / filter, etc.
With certain restrictions, some motor sizes may also be used
in water with temperatures of up to t = +50 °C or for operation
without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).
55
60 Hz UPA 200, 200B, 250C
Design Features
56
60 Hz UPA 200, 200B, 250C
57
60 Hz UPA 200
58
60 Hz UPA 200
UPA 200 - 11 / ..
The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.
UPA 200 -- 11 /..
(Tolerances to
Selection ISO 9906 Class 2)
59
60 Hz UPA 200
UPA 200 --14 for Well Diameters of 200 mm (8 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature of Rated Effi- Power Number x cross-section of
head power the fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤+30 _C)
H0 PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
UPA 200 -- 14/ ... + ... m kW hp _C A % ---- mm2 mm2
1e + UMA 150D 5/21 25.1 5.0 6.7 43 11.4 75.2 0.77 4 x 2.5 3/4 x 2.5 4)
1d + UMA 150D 5/21 30.2 6.0 8.0 41 12.9 75.5 0.81 4 x 2.5 3/4 x 2.5 4)
1 + UMA 150D 7/21 35.5 7.5 10.1 40 15.6 77.3 0.81 4 x 2.5 3/4 x 2.5 4)
2e + UMA 150D 9/21 50.4 10.0 13.4 36 19.8 78.5 0.83 4 x 2.5 3/4 x 2.5 4)
2d + UMA 150D 9/21 60.4 11.2 15.0 31 21.5 78.1 0.85 4 x 2.5 3/4 x 2.5 4)
2 + UMA 150D 13/21 72.1 14.5 19.4 36 27.5 81.7 0.82 4 x 2.5 3/4 x 2.5 4)
3d + UMA 150D 15/21 92.1 17.5 23.5 34 32.0 82.4 0.84 4 x 4.0 3/4 x 2.5 4)
3 + UMA 150D 18/21 108.7 22.0 29.5 32 40.5 82.7 0.83 4 x 4.0 3/4 x 2.5 4)
4c + UMA 150D 22/21 131.2 25.0 33.5 35 45.5 84.6 0.82 4 x 4.0 3/4 x 2.5 4)
4 + UMA 150D 26/21 145.9 29.0 38.9 37 52.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
5c + UMA 150D 26/21 163.6 31.2 41.8 35 55.0 85.4 0.84 4 x 6.0 3/4 x 4.0 4)
5 + UMA 150D 30/21 182.1 36.0 48.3 35 64.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
6c + UMA 150D 37/22 197.7 38.0 51.0 49 69.0 85.4 0.81 3/4 x 4.0 II 3) 3/4 x 4.0 4)
6 + UMA 150D 37/22 217.7 44.0 59.0 45 78.0 84.9 0.84 3/4 x 4.0 II 3) 3/4 x 4.0 4)
7c + UMA 150D 37/22 228.7 44.0 59.0 44 78.0 84.9 0.84 3/4 x 4.0 II 3) 3/4 x 4.0 4)
7 + UMA 200D 45/21 256.0 52.0 69.7 30 89.0 85.7 0.87 4 x 10 3/4 x 6.0 4)
8 + UMA 200D 55/21 294.1 60.0 80.5 32 101.0 86.8 0.86 4 x 16.0 3/4 x 6.0 4)
9 + UMA 200D 65/21 332.2 68.0 91.2 34 115.0 87.6 0.85 3/4 x 10 II 3) 3/4 x 10.0 4)
1) Also see pages 3 and 55
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
60
60 Hz UPA 200
UPA 200 - 14 / ..
The characteristic curves shown are for
preliminary selection only. Exact selection
data will be provided in our quotation.
UPA 200 -- 14 /..
(Tolerances to
ISO 9906 Class 2)
Selection
The pressure losses Hv in the check valve are
not considered in the pump characteristic
curves.
For more details and a selection example
refer to page 8.
Legend ...
Hv : Head losses in the check valve
η p: Pump efficiency
(not considering check valve)
NPSH: Net positive suction head
required by the pump
61
60 Hz UPA 200B, 250C
62
60 Hz UPA 200B, 250C
UPA 200B -- 80 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.
UPA 200B -- 80 /..
(Tolerances to
ISO 9906 Class 2)
Selection
The characteristic curves shown apply to the
standard impeller material, i.e. Noryl.
The performance data for the full impeller diameter
and impeller diameter “b” for the given number of
stages will only be achieved when the impellers are
made of Noryl (PPO).
For the special impeller material (bronze), please
select the next higher number of stages.
In this case, please refer to the characteristic curves
individually prepared for the quotation.
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv : Head losses in the check valve
η p: Pump efficiency
(not considering check valve)
NPSH: Net positive suction head
required by the pump
63
60 Hz UPA 200B, 250C
UPA 200B -- 130 for Well Diameters of 200 mm (8 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature of the Rated Effi- Power Number x cross-section of
head power fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤+30 _C)
H0 PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
UPA 200B -- 130/.. + ... m kW hp _C A % ---- mm2 mm2
1g + UMA 150D 7/21 24.6 9.0 12.1 33 18.0 76.7 0.84 4 x 2.5 3/4 x 2.5 4)
1e + UMA 150D 9/21 28.8 11.2 15.0 32 21.5 78.1 0.85 4 x 2.5 3/4 x 2.5 4)
1c + UMA 150D 13/21 33.2 13.5 18.1 38 26.0 81.9 0.81 4 x 2.5 3/4 x 2.5 4)
1 + UMA 150D 13/21 35.6 15.5 20.8 34 29.0 81.4 0.83 4 x 2.5 3/4 x 2.5 4)
2g + UMA 150D 15/21 48.4 18.0 24.1 34 33.0 82.2 0.84 4 x 4.0 3/4 x 2.5 4)
2e + UMA 150D 18/21 56.8 22.0 29.5 31 40.5 82.7 0.83 4 x 4.0 3/4 x 2.5 4)
2d + UMA 150D 22/21 61.4 25.0 33.5 36 45.5 84.6 0.82 4 x 4.0 3/4 x 2.5 4)
2c + UMA 150D 22/21 64.6 26.0 34.9 34 47.0 84.5 0.83 4 x 4.0 3/4 x 2.5 4)
2 + UMA 150D 26/21 70.1 30.0 40.2 37 54.0 85.5 0.83 4 x 6.0 3/4 x 4.0 4)
3e + UMA 150D 30/21 85.3 33.0 44.3 38 60.0 85.8 0.81 4 x 6.0 3/4 x 4.0 4)
3d + UMA 150D 30/21 91.1 36.0 48.3 36 64.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
3c + UMA 150D 37/22 96.6 40.0 53.6 49 72.0 85.2 0.82 3/4 x 4.0 II 3) 3/4 x 4.0 4)
3 + UMA 150D 37/22 103.8 44.0 59.0 45 78.0 84.9 0.84 3/4 x 4.0 II 3) 3/4 x 4.0 4)
4d + UMA 200D 45/21 122.2 48.0 64.4 33 83.0 85.7 0.86 4 x 10 3/4 x 6.0 4)
4c + UMA 200D 45/21 128.8 52.0 69.7 30 89.0 85.7 0.87 4 x 10 3/4 x 6.0 4)
4b + UMA 200D 55/21 135.3 56.0 75.1 34 96.0 86.8 0.85 4 x 16 3/4 x 6.0 4)
4 + UMA 200D 55/21 140.1 60.0 80.5 33 101.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
5c + UMA 200D 65/21 162.7 66.0 88.5 35 112.0 87.5 0.85 3/4 x 10 II 3) 3/4 x 10 4)
5b + UMA 200D 65/21 169.1 68.0 91.2 33 115.0 87.6 0.85 3/4 x 10 II 3) 3/4 x 10 4)
5 + UMA 200D 65/21 175.1 74.0 99.2 31 124.0 87.6 0.86 3/4 x 10 II 3) 3/4 x 10 4)
6c + UMA 200D 75/21 194.7 78.0 104.6 31 134.0 87.5 0.84 3/4 x 10 II 3) 3/4 x 10 4)
6b + UMA 200D 90/21 204.0 85.0 114.0 35 149.0 88.1 0.82 3/4 x 16 II 3) 3/4 x 16 4)
6 + UMA 200D 90/21 211.5 90.0 120.7 33 156.0 88.2 0.83 3/4 x 16 II 3) 3/4 x 16 4)
7c + UMA 200D 90/21 227.8 95.0 127.4 32 162.0 88.2 0.84 3/4 x 16 II 3) 3/4 x 16 4)
7b + UMA 200D 90/21 236.6 95.0 127.4 31 162.0 88.2 0.84 3/4 x 16 II 3) 3/4 x 16 4)
7 + UMA 250D 110/21 249.5 105.0 140.8 33 181.0 88.6 0.83 3/4 x 16 II 3) 3/4 x 25 4)
8b + UMA 250D 110/21 273.8 115.0 154.2 32 195.0 88.7 0.84 3/4 x 16 II 3) 3/4 x 25 4)
1) Also see pages 3 and 55
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
64
60 Hz UPA 200B, 250C
65
60 Hz UPA 200B, 250C
UPA 250C -- 120 for Well Diameters of 250 mm (10 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section of
head power of the fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤ +30 _C)
Ho PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
UPA 250C -- 120/.. + ... m kW hp _C A % ---- mm2 mm2
1l + UMA 150D 13/21 42.5 15.5 20.8 34 29.0 81.4 0.83 4 x 2.5 3/4 x 2.5 4)
1h + UMA 150D 18/21 50.2 20.0 26.8 35 37.0 83.1 0.82 4 x 4.0 3/4 x 2.5 4)
1f + UMA 150D 18/21 53.7 22.0 29.5 32 40.5 82.7 0.83 4 x 4.0 3/4 x 2.5 4)
1d + UMA 150D 22/21 58.8 25.0 33.5 36 45.5 84.6 0.82 4 x 4.0 3/4 x 2.5 4)
1 + UMA 150D 26/21 62.5 29.0 38.9 38 52.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
2l + UMA 150D 26/21 82.6 31.2 41.8 35 55.0 85.4 0.84 4 x 6.0 3/4 x 4.0 4)
2k + UMA 150D 30/21 90.4 36.0 48.3 35 64.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
2h + UMA 150D 37/22 97.6 42.0 56.3 47 76.0 85.1 0.83 3/4 x 4.0 II 3) 3/4 x 4.0 4)
2f + UMA 150D 37/22 104.3 44.0 59.0 44 78.0 84.9 0.84 3/4 x 4.0 II 3) 3/4 x 4.0 4)
2d + UMA 200D 45/21 114.6 52.0 69.7 31 89.0 85.7 0.87 4 x 10.0 3/4 x 6.0 4)
2 + UMA 200D 55/21 122.3 60.0 80.5 32 101.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
3h + UMA 200D 55/21 144.5 62.0 83.1 31 105.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
3f + UMA 200D 65/21 156.3 68.0 91.2 33 115.0 87.6 0.85 3/4 x 10 II 3) 3/4 x 10 4)
3d + UMA 200D 65/21 169.1 76.0 101.9 30 126.0 87.6 0.87 3/4 x 10 II 3) 3/4 x 10 4)
3 + UMA 200D 90/21 181.0 90.0 120.7 33 156.0 88.2 0.83 3/4 x 16 II 3) 3/4 x 16 4)
4f + UMA 200D 90/21 208.7 95.0 127.4 32 162.0 88.2 0.84 3/4 x 16 II 3) 3/4 x 16 4)
4d + UMA 250D 110/21 229.9 105.0 140.8 34 181.0 88.6 0.83 3/4 x 16 II 3) 3/4 x 25 4)
4 + UMA 250D 132/21 243.8 120.0 160.9 35 200.0 89.3 0.85 3/4 x 25 II 3) 3/4 x 25 4)
5d + UMA 250D 132/21 286.0 130.0 174.3 33 214.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
5 + UMA 250D 160/21 304.0 150.0 201.2 32 247.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
6 + UMA 250D 190/21 366.3 180.0 241.4 32 304.0 90.2 0.83 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
7 + UMA 300D 250/22 434.6 215.0 288.3 62 359.0 89.6 0.84 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
1) Also see pages 3 and 55
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
66
60 Hz UPA 200B, 250C
250
400
67
60 Hz UPA 200B, 250C
UPA 250C --150 for Well Diameters of 250 mm (10 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section of
head power of the fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤ +30 _C)
H0 PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
UPA 250C -- 150/.. + ... m kW hp _C A % ---- mm2 mm2
1l + UMA 150D 18/21 39.1 19.0 25.5 36 36.0 83.2 0.81 4 x 4.0 3/4 x 2.5 4)
1k + UMA 150D 22/21 46.3 24.0 32.2 37 44.0 84.7 0.81 4 x 4.0 3/4 x 2.5 4)
1d + UMA 150D 30/21 55.9 33.0 44.3 38 60.0 85.8 0.81 4 x 6.0 3/4 x 4.0 4)
1 + UMA 150D 37/22 59.6 38.0 51.0 49 69.0 85.4 0.81 3/4 x 4.0 II 3) 3/4 x 4.0 4)
2k + UMA 200D 45/21 92.5 48.0 64.4 32 83.0 85.7 0.86 4 x 10 3/4 x 6.0 4)
2h + UMA 200D 55/21 99.2 54.0 72.4 35 93.0 86.7 0.85 4 x 16 3/4 x 6.0 4)
2f + UMA 200D 55/21 106.8 60.0 80.5 32 101.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
2c + UMA 200D 65/21 113.8 68.0 91.2 34 115.0 87.6 0.85 3/4 x 10 II 3) 3/4 x 10 4)
2 + UMA 200D 65/21 117.7 76.0 101.9 30 126.0 87.6 0.87 3/4 x 10 II 3) 3/4 x 10 4)
3h + UMA 200D 75/21 143.2 80.0 107.3 31 136.0 87.5 0.85 3/4 x 10 II 3) 3/4 x 10 4)
3g + UMA 200D 90/21 151.4 90.0 120.7 34 156.0 88.2 0.83 3/4 x 16 II 3) 3/4 x 16 4)
3d + UMA 200D 90/21 162.6 100.0 134.1 31 169.0 88.2 0.85 3/4 x 16 II 3) 3/4 x 16 4)
3b + UMA 250D 110/21 172.1 110.0 147.5 33 188.0 88.7 0.83 3/4 x 16 II 3) 3/4 x 25 4)
3 + UMA 250D 110/21 176.5 120.0 160.9 31 203.0 88.7 0.84 3/4 x 16 II 3) 3/4 x 25 4)
4e + UMA 250D 132/21 213.0 125.0 167.6 34 207.0 89.3 0.85 3/4 x 25 II 3) 3/4 x 25 4)
4c + UMA 250D 132/21 221.9 135.0 181.0 32 222.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
4b + UMA 250D 160/21 229.3 145.0 194.4 33 241.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
4 + UMA 250D 160/21 235.1 155.0 207.9 31 254.0 89.6 0.86 3/4 x 25 II 3) 3/4 x 35 4) 5)
5d + UMA 250D 190/21 276.2 170.0 228.0 34 291.0 90.2 0.82 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
5b + UMA 250D 190/21 287.2 180.0 241.4 32 304.0 90.2 0.83 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
5 + UMA 300D 250/22 300.9 200.0 268.2 62 341.0 89.3 0.83 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 5) 7)
6b + UMA 300D 250/22 350.5 225.0 301.7 61 373.0 89.8 0.85 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 5) 7)
1) Also see pages 3 and 55
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
68
60 Hz UPA 200B, 250C
250
400
69
60 Hz UPA 200B, 250C
UPA 250C -- 250 for Well Diameters of 250 mm (10 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature of Rated Effi- Power Number x cross-section of
head power the fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤ +30 _C)
H0 PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
UPA 250C -- 250/.. + ... m kW hp _C A % ---- mm2 mm2
1m + UMA 150D 26/21 37.8 29.0 38.9 37 52.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
1k + UMA 150D 26/21 42.1 31.2 41.8 35 55.0 85.4 0.84 4 x 6.0 3/4 x 4.0 4)
1f + UMA 150D 30/21 47.0 36.0 48.3 35 64.0 85.6 0.83 4 x 6.0 3/4 x 4.0 4)
1 + UMA 150D 37/22 54.7 44.0 59.0 44 78.0 84.9 0.84 3/4 x 4.0 II 3) 3/4 x 4.0 4)
2m + UMA 200D 55/21 73.7 58.0 77.8 33 99.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
2l + UMA 200D 55/21 80.3 62.0 83.1 31 105.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
2g + UMA 200D 65/21 89.0 70.0 93.9 33 118.0 87.6 0.86 3/4 x 10 II 3) 3/4 x 10 4)
2e + UMA 200D 65/21 96.1 76.0 101.9 31 126.0 87.6 0.87 3/4 x 10 II 3) 3/4 x 10 4)
2c + UMA 200D 90/21 104.2 85.0 114.0 34 149.0 88.1 0.82 3/4 x 16 II 3) 3/4 x 16 4)
2 + UMA 200D 90/21 108.0 90.0 120.7 33 156.0 88.2 0.83 3/4 x 16 II 3) 3/4 x 16 4)
3h + UMA 200D 90/21 125.8 100.0 134.1 31 169.0 88.2 0.85 3/4 x 16 II 3) 3/4 x 16 4)
3f + UMA 250D 110/21 136.5 110.0 147.5 33 188.0 88.7 0.83 3/4 x 16 II 3) 3/4 x 25 4)
3d + UMA 250D 132/21 149.8 120.0 160.9 35 200.0 89.3 0.85 3/4 x 25 II 3) 3/4 x 25 4)
3 + UMA 250D 132/21 159.0 135.0 181.0 32 222.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
4f + UMA 250D 160/21 181.9 145.0 194.4 34 241.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
4e + UMA 250D 160/21 190.4 150.0 201.2 32 247.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
4c + UMA 250D 190/21 205.9 170.0 228.0 34 291.0 90.2 0.82 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
4 + UMA 250D 190/21 213.4 180.0 241.4 32 304.0 90.2 0.83 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
5e + UMA 250D 190/21 238.5 190.0 254.8 31 317.0 90.2 0.84 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
5b + UMA 300D 250/22 264.4 220.0 295.0 62 367.0 89.7 0.84 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
1) Also see pages 3 and 55
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
70
60 Hz UPA 200B, 250C
250
400
71
60 Hz UPA 200B, 250C
72
60 Hz UPA 300, 350
Application
Handling clean or slightly contaminated water in applications Submersible Borehole Pumps
such as:
-- general water supply
for Well Diameters
-- irrigation and spray irrigation
of 300 mm (12 inches) and Above
-- pressure boosting
and of 350 mm (14 inches) and Above
Single-entry and mixed flow
-- lowering and maintaining ground water levels as well as
-- drainage
Also used in mining, sprinkler installations, fountains etc.
Permissible sand content in the fluid handled: 50 g/m3.
Also suitable for aggressive seawater if supplied in material
variant C3 (duplex).
Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 1080 m3/h (300 l/s
or up to 4000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 474 m
Temperature of fluid handled . . t up to +50 °C
Speed . . . . . . . . . . . . . . . . . . . . . n ≈ 3500 rpm
Design
Single or multistage, single-entry centrifugal pump in
ring-section design. For vertical and horizontal installation.
Mixed flow hydraulic systems with impellers that can be turned
down. Stage casings are connected by means of stud bolts.
Suction casing fitted between pump and motor. Suction casing
equipped with strainer to protect the pump from coarse
particles in the fluid.
Pumps with check valve or connection branch on option. Both
models with threaded or flanged end.
Particularly suitable for vertical installation in narrow deep wells.
Designation (Example)
UPA 300 -- 94 / 5 b
Available automation products:
Type series
• Hyamaster
Minimum well diameter (mm)
(for ex.: 300 mm = 12 inches) (for UPA 300)
Capacity Qopt at 50 Hz (l/s)
Number of stages
Reduced impeller diameter(s)
Product Features
Certification -- Very sturdy design
-- Suitable for installation in narrow deep wells
Quality management certified to ISO 9001
-- High efficiency
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical or horizontal installation
-- Non-return valve protected against blocking
-- Pre-filled motor; no risk of contamination of the handled
water
73
60 Hz UPA 300, 350
UPA 300 -- 94
UPA 300 -- 65
UPA 300 -- 65
Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this range. The operating
ranges ∆QB of the individual pump sizes are given in the characteristic curves for different stage numbers on the following pages.
74
60 Hz UPA 300, 350
Wear-resistant mechanical
seal
-- Long service life and high
operating reliability.
The KSB motor
-- Efficiencies up to 91 %.
-- VDE-compliant, i.e. high level of
electrical safety.
-- Designed for max. pump power to
protect unit from overloads.
Counter thrust bearing
-- Reliable balancing of negative
axial thrust.
-- Impellers do not rub on the stage
casings.
Dynamically balanced rotor
-- Ensures smooth running.
Tried and tested thrust bearing
-- Water-lubricated self-aligning
tilting-pad journal bearing.
-- No-maintenance design suitable
for maximum load-carrying Reliable pressure balancing system
capacity under continuous -- Optimum rubber expansion diaphragm
operation conditions. design.
-- New materials combination -- Enables installation at very low depths
(stainless steel / carbon) for high
safety factor.
3411:10
76
60 Hz UPA 300, 350
77
60 Hz UPA 300, 350
UPA 300 -- 65 for Well Diameters of 300 mm (12 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section of
head power of the fluid handled current ciency factor conductors (use under water,
Q=0 m3/h v ≥ 0.5 m/s 460 V and ≤ 30 _C)
Ho PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
m kW hp _C A % ---- mm2 mm2
UPA 300 -- 65/ ... + ...
1n + UMA 200D 37/21 42.1 26.0 34.9 41 49.5 83.5 0.79 4 x 10 3/4 x 6.0 4)
1m + UMA 200D 37/21 49.9 34.0 45.6 38 61.0 84.6 0.84 4 x 10 3/4 x 6.0 4)
1l + UMA 200D 37/21 54.5 38.0 51.0 35 67.0 84.8 0.85 4 x 10 3/4 x 6.0 4)
1f + UMA 200D 45/21 59.6 46.0 61.7 34 80.0 85.7 0.85 4 x 10 3/4 x 6.0 4)
1 + UMA 200D 55/21 69.0 60.0 80.5 32 101.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
2m + UMA 200D 65/21 101.5 68.0 91.2 34 115.0 87.6 0.85 3/4 x 10 II 3) 3/4 x 10 4)
2l + UMA 200D 75/21 111.4 78.0 104.6 31 134.0 87.5 0.84 3/4 x 10 II 3) 3/4 x 10 4)
2g + UMA 200D 90/21 120.4 95.0 127.4 32 162.0 88.2 0.84 3/4 x 16 II 3) 3/4 x 16 4)
2d + UMA 250D 110/21 132.9 110.0 147.5 33 188.0 88.7 0.83 3/4 x 16 II 3) 3/4 x 25 4)
2 + UMA 250D 132/21 142.9 125.0 167.6 34 207.0 89.3 0.85 3/4 x 25 II 3) 3/4 x 25 4)
3k + UMA 250D 132/21 171.4 130.0 174.3 33 214.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
3h + UMA 250D 160/21 179.9 145.0 194.4 34 241.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
3e + UMA 250D 160/21 189.2 155.0 207.9 32 254.0 89.6 0.86 3/4 x 25 II 3) 3/4 x 35 4) 5)
3d + UMA 250D 190/21 199.9 170.0 228.0 34 291.0 90.2 0.82 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
3 + UMA 300D 250/22 218.8 200.0 268.2 63 341.0 89.3 0.83 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
4g + UMA 300D 250/22 248.3 200.0 268.2 63 341.0 89.3 0.83 3/3x70 II + 1x35 3)6) 6x95 + 1x50 4) 7)
4e + UMA 300D 250/22 258.0 215.0 288.3 62 359.0 89.6 0.84 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
4b + UMA 300D 250/22 276.7 240.0 321.8 61 394.0 90.0 0.85 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
4 + UMA 300D 250/22 289.9 265.0 355.4 59 429.0 90.2 0.86 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
5e + UMA 300D 250/22 320.9 265.0 355.4 59 429.0 90.2 0.86 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
5b + UMA 300D 250/22 344.0 295.0 395.6 57 471.0 90.4 0.87 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
5 + UMA 300D 300/22 362.4 330.0 442.5 59 534.0 90.8 0.86 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
6c + UMA 300D 300/22 408.4 345.0 462.7 58 554.0 90.9 0.86 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
6 + UMA 300D 400/22 432.9 390.0 523.0 57 622.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
7c + UMA 300D 400/22 474.6 400.0 536.4 56 634.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
1) Also see pages 3 and 75
2) 3/4 = 1 x 3-core + 1 x 4-core. flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
78
60 Hz UPA 300, 350
UPA 300 -- 65 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.
UPA 300 -- 65
(Tolerances to
ISO 9906 Class 2)
Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv : Head losses in the check valve
η p: Pump efficiency
(not considering check valve)
NPSH: Net positive suction head
required by the pump
Optimum im-
peller dia. “b”
79
60 Hz UPA 300, 350
UPA 300 -- 94 for Well Diameters of 300 mm (12 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section of
head power of the fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤ +30 _C)
Ho PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
m kW hp _C A % ---- mm2 mm2
UPA 300 -- 94/ ... + ...
1n + UMA 200D 45/21 49.0 48.0 64.4 32 83.0 85.7 0.86 4 x 10 3/4 x 6.0 4)
1m + UMA 200D 55/21 54.5 56.0 75.1 34 96.0 86.8 0.85 4 x 16 3/4 x 6.0 4)
1k + UMA 200D 55/21 62.5 62.0 83.1 31 105.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
1g + UMA 200D 65/21 68.1 72.0 96.6 32 120.0 87.6 0.86 3/4 x 10 II 3) 3/4 x 10 4)
1d + UMA 200D 75/21 73.4 80.0 107.3 31 136.0 87.5 0.85 3/4 x 10 II 3) 3/4 x 10 4)
1 + UMA 200D 90/21 78.7 95.0 127.4 32 162.0 88.2 0.84 3/4 x 16 II 3) 3/4 x 16 4)
2m + UMA 250D 110/21 113.3 110.0 147.5 32 188.0 88.7 0.83 3/4 x 16 II 3) 3/4 x 25 4)
2k + UMA 250D 132/21 131.7 130.0 174.3 33 214.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
2h + UMA 250D 160/21 139.7 145.0 194.4 34 241.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
2d + UMA 250D 190/21 153.4 170.0 228.0 34 291.0 90.2 0.82 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
2 + UMA 300D 250/22 167.1 200.0 268.2 63 341.0 89.3 0.83 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
3k + UMA 300D 250/22 205.5 200.0 268.2 63 341.0 89.3 0.83 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
3h + UMA 300D 250/22 216.8 220.0 295.0 62 367.0 89.7 0.84 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
3e + UMA 300D 250/22 230.7 235.0 315.1 61 386.0 89.9 0.85 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
3c + UMA 300D 250/22 240.0 265.0 355.4 59 429.0 90.2 0.86 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
3 + UMA 300D 250/22 251.5 295.0 395.6 57 471.0 90.4 0.87 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
4f + UMA 300D 300/22 300.9 315.0 422.4 59 513.0 90.7 0.85 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
4c + UMA 300D 300/22 319.4 350.0 469.4 57 562.0 90.9 0.86 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
4 + UMA 300D 400/22 335.2 390.0 523.0 57 622.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
5e + UMA 300D 400/22 382.2 390.0 523.0 57 622.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
1) Also see pages 3 and 75
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
80
60 Hz UPA 300, 350
UPA 300 -- 94 / ..
The characteristic curves shown are for preliminary
selection only. Exact selection data will be provided
in our quotation.
UPA 300 -- 94
(Tolerances to
ISO 9906 Class 2)
Selection
The pressure losses Hv in the check valve are not
considered in the pump characteristic curves.
For more details and a selection example refer to
page 8.
Legend ...
Hv : Head losses in the check valve.
η p: Pump efficiency
(not considering check valve).
NPSH: Net positive suction head
required by the pump.
385
81
60 Hz UPA 300, 350
UPA 350 -- 128 for Well Diameters of 350 mm (14 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated Max. temperature Rated Effi- Power Number x cross-section of
head power of the fluid handled current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤ 30 _C)
Ho PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
m kW hp _C A % ---- mm2 mm2
UPA 350 -- 128/ ... + ...
1l + UMA 200D 55/21 56.9 60.0 80.5 32 101.0 86.8 0.86 4 x 16 3/4 x 6.0 4)
1k + UMA 200D 75/21 65.8 78.0 104.6 32 134.0 87.5 0.84 3/4 x 10 II 3) 3/4 x 10 4)
1h + UMA 200D 90/21 74.9 100.0 134.1 31 169.0 88.2 0.85 3/4 x 16 II 3) 3/4 x 16 4)
1f + UMA 250D 110/21 83.2 115.0 154.2 32 195.0 88.7 0.84 3/4 x 16 II 3) 3/4 x 25 4)
1d + UMA 250D 132/21 91.9 135.0 181.0 32 222.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
1b + UMA 250D 160/21 100.0 155.0 207.9 31 254.0 89.6 0.86 3/4 x 25 II 3) 3/4 x 35 4) 5)
1 + UMA 250D 190/21 109.0 185.0 248.1 31 311.0 90.2 0.83 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
2h + UMA 300D 250/22 154.9 205.0 274.9 62 347.0 89.5 0.83 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2g + UMA 300D 250/22 162.6 220.0 295.0 62 367.0 89.7 0.84 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2e + UMA 300D 250/22 174.6 245.0 328.6 60 400.0 90.1 0.86 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2c + UMA 300D 250/22 189.0 280.0 375.5 58 450.0 90.3 0.87 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2b + UMA 300D 300/22 204.1 315.0 422.4 59 513.0 90.7 0.85 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
2 + UMA 300D 300/22 220.4 360.0 482.8 57 575.0 91.0 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
3c + UMA 300D 400/22 282.3 415.0 556.5 56 658.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
1) Also see pages 3 and 75
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
82
60 Hz UPA 300, 350
448
365 -- pedestals for motor
440 -- pedestals for pump
83
60 Hz UPA 300, 350
UPA 350 -- 180 for Well Diameters of 350 mm (14 inches) and Above
Pumps with submersible motors for ... -- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3~) / 460 V
-- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-∆)
Pump unit Pump Motor Motor lead 2), flat
Discharge Rated of the fluid handled Rated Effi- Power Number x cross-section of
head power Max. temperature current ciency factor conductors (use under water,
Q = 0 m3/h v ≥ 0.5 m/s 460 V and ≤ 30_C)
Ho PN PN tmax 1) IN ηM cos φ D.o.l. Y-∆
m kW hp _C A % ---- mm2 mm2
UPA 350 -- 180/ ... + ...
1m + UMA 200D 90/21 59.3 95.0 127.4 32 162.0 88.2 0.84 3/4 x 16 II 3) 3/4 x 16 4)
1l + UMA 250D 110/21 66.0 110.0 147.5 33 188.0 88.7 0.83 3/4 x 16 II 3) 3/4 x 25 4)
1h + UMA 250D 110/21 71.0 115.0 154.2 31 195.0 88.7 0.84 3/4 x 16 II 3) 3/4 x 25 4)
1e + UMA 250D 132/21 80.8 135.0 181.0 32 222.0 89.3 0.86 3/4 x 25 II 3) 3/4 x 25 4)
1c + UMA 250D 160/21 89.7 150.0 201.2 33 247.0 89.7 0.85 3/4 x 25 II 3) 3/4 x 35 4) 5)
1 + UMA 250D 190/21 96.3 175.0 234.7 33 297.0 90.2 0.82 3/4 x 35 II 3) 5) 3/4 x 35 4) 5)
2k + UMA 300D 250/22 141.7 230.0 308.4 61 381.0 89.9 0.85 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2g + UMA 300D 250/22 149.9 245.0 328.6 60 400.0 90.1 0.86 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2f + UMA 300D 250/22 164.3 265.0 355.4 59 429.0 90.2 0.86 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2d + UMA 300D 250/22 177.6 290.0 388.9 57 463.0 90.4 0.87 3/3x70 II + 1x35 3) 6) 6x95 + 1x50 4) 7)
2b + UMA 300D 300/22 189.0 320.0 429.1 59 521.0 90.8 0.85 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
2 + UMA 300D 300/22 198.2 360.0 482.8 57 575.0 91.0 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
3f + UMA 300D 400/22 244.5 405.0 543.1 56 642.0 91.1 0.87 6x95 II + 1x50 3) 7) 6x95 + 1x50 4) 7)
1) Also see pages 3 and 75
2) 3/4 = 1 x 3-core + 1 x 4-core, flat, 90_ spacing.
3) 2 cables in parallel.
4) Delta wiring in the cable connector or control cabinet.
5) 1 x 3--core flat + 1 x 4--core round.
6) 2 x 3--core flat + 1 x 1--core round.
7) 6 x 1--core round + 1 x 1--core round.
84
60 Hz UPA 300, 350
448
365 -- pedestals for motor
440 -- pedestals for pump
85
60 Hz UPA 300, 350
86
60 Hz BSX, BSF
Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 2200 m3/h (610 l/s
or up to 10,000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 240 m
Temperature of liquid handled . t up to + 50 oC
Speed . . . . . . . . . . . . . . . . . . . . . n ≈ 1750 rpm
Design
Single- or multi-stage, single-flow centrifugal pumps in
ring-section design. For vertical, angled and horizontal
installation. Mixed-flow hydraulics with reducibles impellers.
The stage casings are connected by means of studs.
Suction casing between pump and motor with suction strainer
as protection of pump against coarse impurities of the liquid
handled.
Pump end at choice with non-return valve or connection nozzle.
Either design with flanged connection.
Especially suitable for installation in narrow deep wells.
Designation
B R Z S 535 / 5 a
Type series
Design status
Minimum well diameter (mm) 1)
Suction impeller
Code for hydraulics (50 Hz)
Number of stages
Impellers reduced Product Features
1) X = 400 mm (16 inches), Y = 450 mm (18 inches), -- Very sturdy design
Z = 500 mm (20 inches), E = 600 mm (24 inches), -- Suitable for installation in narrow deep wells
F = 650 mm (26 inches)
-- High efficiency
-- Motor designed for maximum pump output
-- Low noise level
Certification -- For vertical or horizontal installation
Quality management certified to ISO 9001 -- Non-return valve protected against blocking
-- Pre-filled motor without risk of contamination of the pumped
water
87
60 Hz BSX, BSF
500
400
300 1000
BRY 504 BRZS 535
H
BRE 555
m
200 BSX 463
BSF 586
150 500
400
100
300
80 H
ft
60 200
50
40
30 100
80
20
60
15
40
10
200 300 400 500 Q m3/h 1000 2000 3000
40 60 80 100 Q l/s 200 300 400 600 800
3430:80
88
60 Hz BSX, BSF
Materials Drive
Component Execution G Execution B KSB submersible motors DN 300 and above in squirrel-cage
design, three-phase current (3~), 4 poles. For low (U = 1000 V)
Pump ... and high (U = 6000V) voltage. Water-filled motor. The water fill
Cast iron JL1030 lubricates the bearings and cools the windings sealed with
Casing Bronze (G-CuSn10) water-tight insulation material. The shaft is sealed by lip seals
(GG-20)
protected against ingress of sand or a mechanical seal.
Impeller Bronze (G-CuSn10) Pressure differences between motor and environment are
CrNiMo steel equalized by a rubber expansion diaphragm in the motor.
Shaft Cr steel (1.4021)
(1.4462) Construction complies with VDE regulations.
Wear rings Bronze (2.1090)
Cr steel (1.4021) Alu bronze
Bearings annealed / (G-CuAl11Ni) / Electrical Connection
special bronze special bronze
The motors are equipped ex works with 2 short cables.
Generally with earthing.
Component Execution G Connection of extension cable by means of a waterproof cable
Motor ... connector. At choice connection of the complete cable length
direct at the winding in the submersible motor.
Shaft Steel (C 45) enclosed
Short cable and extension cable for low voltage (U ≤ 1000 V)
Cast parts Cast iron JL1030 (GG-20)
in food quality.
Stator jacket Steel (St 37)
Starting Methods
Bearings / Lubrication Low voltage (U ≤ 1000 V): direct on line (without or with starting
transformer as well as with smooth running device) and
Pump:
star-delta.
1 radial plain bearing in suction casing and in bearing bracket
High voltage (U > 1000 V): only direct on line.
housing resp. in last stage (BSF 586). Dependent on pump size
and number of stages additionally 1 intermediate bearing.
Lubricated by the liquid handled.
Motor:
Application Temperatures
The submersible units are so designed as to allow also
2 radial plain bearings and 1 thrust bearing with tilting pads for
operation without additional cooling in the motor area, e.g.
balancing of axial thrust. Lubricated by the motor fill water.
installation in a deep well, in a big tank etc. (the liquid handled
does not stream directly along the motor).
With additional cooling, e.g. installation in the deep well above
the filter area, execution with cooling shroud etc. (the liquid
Direction of Rotation of the Pump handled streams along the motor with v ≥ 0.5 m/s), the
Right-handed, i.e. clockwise rotation submersible units can be used in water of elevated
(viewed at the drive shaft end). temperatures (additionally 5 °C and more).
Mode of Installation
Generally vertical installation. Dependent on number of stages
and the motor size also horizontal installation possible.
89
60 Hz BSX, BSF
Design Features
The coating and the cable in food
quality (BAM)1)
The non-return valve with double- -- For use without any problems in
guided valve plate drinking water area.
-- No jamming or canting. 1) German federal inst. for materials
-- With valve plate spring loaded. research
Thus allows minimum closing-times
and avoids consequently The enclosed pump bearing
waterhammers. -- Maintenance-free and extensively
protected against wear.
-- Long-term operation without
problems.
The steadfast wear rings The mixed-flow impellers
-- Replaceable rings (standardly with -- Reducibles. Thus caused optimum
casing and impeller wear ring) out of adaptation to need of pump heads.
wear- and corrosion-resistant metal. -- With keys for reliable power
-- They protect against gap wear and transmission and simplified
allow easy servicing. dismantling and mounting.
90
60 Hz UPZ
Applications
Handling clean and raw water in applications such as: Submersible Borehole Pumps
-- general water extraction / supply,
for Well Diameters
-- irrigation and spray irrigation,
of 500 mm (20 inches) and Above
-- lowering and maintaining ground water levels in open-cast
mines, Double entry, back-to-back impeller arrangement
-- dewatering and gallery drainage in underground mines.
Use in pressure-boosting and sprinkler systems, as well as for
offshore and cavern applications, etc.
Permissible sand content in the fluid handled: 50 g/m3.
Operating Data
Capacity . . . . . . . . . . . . . . . . . . . Q up to 2200 m3/h (612 l/s
or up to 10,000 US GPM)
Head . . . . . . . . . . . . . . . . . . . . . . H up to 1500 m
Supply voltage . . . . . . . . . . . . . . U up to 6600 V
Temperature of fluid handled . . t up to +40 oC
Speed . . . . . . . . . . . . . . . . . . . . . n 3500 rpm and 1750 rpm
Design
Multistage, double-entry ring-section pump with back-to-back
impeller arrangement. For vertical installation. Radial and
mixed-flow hydraulic systems with impellers that can be turned
down.
Half the flow enters the pump through the lower suction casing,
the other half through the upper suction casing. The upper half
of the pump unit is surrounded by a pump shroud (outer shell).
The two flows are collected by the channel created by the
shroud and carried into the upper suction casing, which is
equipped with two discharge branches. This design
theoretically ensures full axial thrust balancing. The casing
components (stage casings) are connected by means of round
tie bolts. The two suction casings are equipped with strainers
to protect the pump from coarse particles in the fluid. Flanged
pump end. Check valve with flanged end available on request.
Particularly suitable for installation in narrow deep wells.
Type series
Capacity Qopt (l/s)
Nominal impeller diameter (mm)
Number of stages
Certification
Quality management certified to ISO 9001
91
60 Hz UPZ
4000
1000
n = 1450 1/min
3000
H
m
2000
500
H
400 ft
800
700
200
600
150 500
400
100
300
200
50
40
50 100 Q m3/h 200 300 400 500 1000 2000
3470:1
20 30 50 100 Q l/s 200 300 500
Note: The diagram shows the ∆QA range on offer. The pumps can be offered for any duty point within this flow range.
92
60 Hz UPZ
Bearings / Lubrication
Starting
Pump:
1 radial plain bearing in each suction casing. Depending on the Low voltage (U ≤ 1000 V): d.o.l. (without or with autotransformer
pump size and number of stages, 1 additional intermediate / with or without soft starter) and star-delta (Y-∆)starting.
bearing each in the two pump halves. Lubricated by the fluid High voltage (U > 1000 V): d.o.l starting only.
handled.
Motor:
2 radial plain bearings. Residual axial thrust is balanced by 1 Variants Available on Request
self-aligning tilting-pad thrust bearing in the motor (lower end).
-- Other materials
Lubricated by the motor’s water fill.
-- Higher fluid temperatures
-- More wear-resistant designs
Direction of Rotation of the Pump -- Models with cooling or pump shroud
-- Special coating
Clockwise rotation (when looking at the drive shaft end).
-- Special explosion protection up to 6 kV
93
60 Hz UPZ
Design Features
High efficiency ηM
Winding insulation (J2)
-- Reduced operating costs thanks to
-- Cu--VPE--PA material makes for maximum optimized windings.
heat resistance.
Sealing elements
-- All joints sealed by O-rings. Pressure--proof
up to a differential pressure of 16 bar. Reliable pressure balancing system
-- Optimum selection thanks to
generously sized rubber diaphragm.
-- Enables installation at very low
depths.
94
60 Hz Submersible Borehole Pumps
95
60 Hz Submersible Borehole Pumps
96
60 Hz Submersible Borehole Pumps
97
60 Hz Submersible Borehole Pumps
98
60 Hz Submersible Borehole Pumps
99
60 Hz Submersible Motors
Submersible Motors for Well Diameters DN 100, 150, UMA 150D, 200D, 250D and 300D
of 100 mm (4 inches) and above
Sizes / Connection
DN 100, DN 150, UMA 150D, UMA200D: NEMA standard
UMA 250D, UMA 300D: KSB standard
433
940.52
412.53
Material Variants (Material specifications to EN) 271
914.53
160.52
DN 100 550.53
900.52
Component G (Standard) 723
145
All components CrNi steel 710
DN 150 829
901.51 828
Component G (Standard)
550.52 829
Shaft CrNi steel
504
Bearing carrier Cast iron (JL1030) 4)
932.52
Stator case CrNi steel
UMA
Compo- G (Standard) C1 (Special) C3 (Duplex) 914.52 545
nents 529
Shaft CrNi steel CrNiMo steel CrNiMo steel 382.52
(1.4305 2) ) (1.4462 2) ) ((1.4462))
CrNiMo steel(1.4462)
Housing Cast iron CrNiMo steel CrNiMo steel 818
(JL1030 4) / (1.4408 / (1.4539 /
JL 1040 5) 6) ) 1.4409 2) / 1.4517 5) )
1.4517 5) )
Stator CrNi steel CrNiMo steel CrNiMo steel
case (1.4301) (1.4571 / ( 1.4539 / 81--59
1.4462 5) ) 1.4462 5) ) 23--2
Screws, CrNiMo steel CrNiMo steel
bolts and (A4-70) ( 1.4539 /
nuts 3) 1.4462 5) )
2) UMA 150D motors only 4) DIN mat. code: GG-20
3) Wetted by fluid pumped. 5) UMA 300D motors only
6) DIN mat. code: GG-25 814
545
Bearings / Lubrication 382.51
Two radial plain bearings as well as a thrust bearing to balance
529
the pump’s axial thrust.
Lubrication by motor fill liquid. 900.51
384 940.51
Direction of Rotation of the Motor 389
Anti-clockwise rotation (when looking at the drive shaft end). 932.51
412.51
Variants Available on Request 412.52 387
-- DN 100: Other supply voltages up to 500 V 914.51 32--2
-- UMA 150D -- 300D: Other supply voltages up to 1000 V 550.51 392
Part No. Description 59--6 903
145 Adapter 904.52
354 Thrust bearing housing 381
382.51/52 Bearing carrier (bottom) / (top) 904.51 59--42
553 920.51
384/387 Thrust bearing plate / segment
354 916.51
389 Counter thrust bearing ring
484 59--12
433 Mechanical seal
160.51
59-12 Membrane 950
500.51
500.52
529/545.51 Bearing sleeve / Bearing bush
81-59 Stator with windings
818 Rotor
e.g. UMA 250 D
828/829.51 Cable grommet / Cable gland ring
100
60 Hz Submersible Motors
Submersible Motors DN 100, UMA 150D to 300D: 3~, n≈ 3500 1/min, d.o.l. + Y-∆
PN IN ηM cos φ Cu ∅ D L m
3~ (submerged) Standard Standard
460 V 4/4 4/4 d.o.l. Y-∆ 1~ 3~ 1~ 3~
Motor size kW hp A % -- mm2 mm2 mm
¶ mm ¶ kg
DN 100 ...
0.37 0.59 0.8 1.5 70 0.76 4 x 1.5 ---- 242 223 8.3 7.3
0.55 0.83 1.1 2.1 73 0.74 4 x 1.5 ---- 271 242 9.6 8.3
0.75 1.0 1.3 2.4 72 0.79 4 x 1.5 ---- 299 271 10.8 9.6
1.1 1.4 1.9 3.1 74 0.82 4 x 1.5 ---- 327 299 13.5 10.8
1.5 1.8 2.4 4.1 74 0.80 4 x 1.5 ---- 356 327 14.4 12.1
96
2.2 2.5 3.4 5.6 77 0.77 4 x 1.5 ---- 460 356 18.0 13.5
3.0 3.4 4.5 7.4 79 0.76 4 x 1.5 ---- ---- 423 ---- 16.0
3.7 4.2 5.6 8.7 78 0.79 4 x 1.5 ---- ---- 552 ---- 22.5
5.5 6.4 8.6 13.1 78 0.82 4 x 1.5 ---- ---- 704 ---- 29.0
7.5 8.6 11.6 17 78 0.82 4 x 1.5 ---- ---- 780 ---- 33.0
UMA 150D ...
UMA 150D 5/21 6.6 9 13.4 76 0.82 4 x 2.5 3/4 x 2.5 ---- 699 ---- 48
UMA 150D 7/21 9 12.2 17.5 77.5 0.84 4 x 2.5 3/4 x 2.5 ---- 719 ---- 50
UMA 150D 9/21 11.2 15.2 21.2 79 0.84 4 x 2.5 3/4 x 2.5 ---- 749 ---- 53
UMA 150D 13/21 15.6 21.2 28.9 82 0.83 4 x 2.5 3/4 x 2.5 ---- 829 ---- 58
UMA 150D 15/21 18 24.5 32.5 83 0.84 4 x 4.0 3/4 x 2.5 ---- 874 ---- 62
143
UMA 150D 18/21 22.2 30.2 40.2 83 0.84 4 x 4.0 3/4 x 2.5 ---- 919 ---- 67
UMA 150D 22/21 26.4 35.9 47.2 85 0.83 4 x 4.0 3/4 x 2.5 ---- 1009 ---- 76
UMA 150D 26/21 31.2 42.4 54.8 85.5 0.83 4 x 6.0 3/4 x 4.0 ---- 1114 ---- 87
UMA 150D 30/21 36 49 63.8 86 0.83 4 x 6.0 3/4 x 4.0 ---- 1214 ---- 97
UMA 150D 37/22 44 59.8 77.4 85.5 0.84 3/4 x 4.0 2) 3/4 x 4.0 ---- 1294 ---- 101
UMA 200D ...
UMA 200D 37/21 45 61 78 86 0.85 3/4 x 10 2) 3/4 x 10 ---- 1140 ---- 130
UMA 200D 45/21 55 75 94 87 0.85 3/4 x 6 2) 3/4 x 6 ---- 1230 ---- 145
UMA 200D 55/21 66 90 112 88 0.85 3/4 x 6 2) 3/4 x 6 ---- 1340 ---- 165
189
UMA 200D 65/21 77 105 129 88.5 0.84 3/4 x 10 2) 3/4 x 10 ---- 1470 ---- 187
UMA 200D 75/21 90 122 153 88 0.84 3/4 x 10 2) 3/4 x 10 ---- 1560 ---- 203
UMA 200D 90/21 118 161 167 89 0.84 3/4 x 16 2) 3/4 x 16 ---- 1740 ---- 235
UMA 250D ...
UMA 250D 85/21 102 138 169 88 0.86 3/4 x 10 II 3/4 x 16 ---- 1419 ---- 260
UMA 250D 110/21 132 180 218 88.5 0.86 3/4 x 25 2) 3/4 x 25 ---- 1529 ---- 295
UMA 250D 132/21 158 215 258 89 0.86 3/4 x 25 2) 3/4 x 25 232 ---- 1659 ---- 340
UMA 250D 160/21 192 261 312 89.5 0.87 3/4 x 25 II 3/4 x 35 ---- 1769 ---- 390
UMA 250D 190/21 228 310 369 89.5 0.87 3/4 x 35 II 3/4 x 50 ---- 1919 ---- 428
UMA 300D ...
UMA 300D 180/22 210 3) 386 339 89 0.88 3/4 x 35 II 3/4 x 35 ---- 1808 ---- 535
UMA 300D 210/22 250 3) 340 403 89.5 0.87 3/4 x 35 II 3/4 x 35 ---- 1908 ---- 575
UMA 300D 250/22 280 3) 381 446 90 0.88 3/4 x 50 II 3/4 x 50 ---- 2038 ---- 645
282
UMA 300D 280/22 310 3) 422 494 90.5 0.87 3/3 x 70 II 2 x 3 x 70 ---- 2108 ---- 680
UMA 300D 310/22 350 3) 476 553 91.5 0.87 3/3 x 70 II 2 x 3 x 70 ---- 2208 ---- 720
UMA 300D 350/22 400 3) 544 622 91.5 0.88 7 x 1 x 95 II 7 x 1 x 95 ---- 2308 ---- 780
2) ∆-wiring of the 2 standard short cables for d.o.l. starting in the cable connector or in the control box.
3) Leistungsreduzierung für Y∆ -- Einschaltung
Additional motor data: Motor cable:
Frequency of starts . . . . . . . . . . . . . . . . . . . . . . . . . . 100 ≤ 20/h DN 100: L = 1.5 m (≤ 1.5 kW) / 2.5 m (> 1.5 kW), 1 x
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 150D: ≤ 15/h DN 150: L = 4 m, 1 x or 2 x
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 200D/250D: ≤ 10/h UMA 150D: L = 4 m, 1 x or 1 x +1x
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D ≤ 280/22: ≤ 10/h UMA 200B: L = 6 m, 1 x +1x
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D ≥ 310/22: ≤ 5/h UMA 250B: L = 6 m, 1 x +1x or
Horizontal installation . . . . . . . . . . . . . . . . . . DN 100: all sizes
1x +1x (≥ 35 mm2)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 150D: ≤ 30/21
UMA 300D: L = 10m, 1 x +1x or
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 200D: ≤ 75/21
2x (70 mm2) + 1 x (35 mm2) or
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 250D: ≤ 160/21
6x +1x (95 mm2)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UMA 300D: ≤ 310/22
Other cables on request.
101
60 Hz Accessories
Accessories
Description Ident. No. ≈ kg
Separately available:
-- Short cable: 1.5 m long, 4 x 1.5 mm2, with plug and cable joint 00 117 947 0.4
2.5 m long, 4 x 1.5 mm2, with plug and cable joint 01 025 739 0.7
-- Cable joint: for 1 x 4 x 1.5 mm2, flat, or up to 1 x 4 x 4 mm2, round 00 117 792 0.2
1) For permissible cable lengths see pages 108 and 109.
102
60 Hz Accessories
Accessories
Description Ident. No. ≈ kg
Cable connector, non-separable, including sealing compound,
for connecting 1 extension cable to 1 or 2 motor leads
-- Size 28 for connecting 1 extension cable to ...
1 motor lead . . . . . . . . . . . . . . . . . -- supplied, but not connected 95 005 106 0.45
-- connected and sealed at the factory . 90 049 385 0.45
-- Size 35 for connecting 1 extension cable to ...
1 motor lead . . . . . . . . . . . . . . . . . -- supplied, but not connected 90 049 397 0.5
-- connected and sealed at the factory 90 049 387 0.5
-- Size 43 for connecting 1 extension cable to ...
a) 1 motor lead . . . . . . . . . . . . . . -- supplied, but not connected 90 049 399 0.55
-- connected and sealed at the factory 90 049 389 0.55
b) 2 motor lead -- supplied, but not connected 90 049 400 0.55
-- connected and sealed at the factory . 90 049 390 0.55
3300:236/2 Sizes 53 to 78 available on request.
For selection see details and examples on page 110.
Cable tie for fastening power supply cable to riser
-- Size 1
(rubber strap / plastic studs),
for cable sizes up to 1 FL 3 x 6 mm2 or 4 x 6 mm2 and 1 RD 4 x 6 mm2 . 90 006 993 0.04
-- Sizes 2 -- 11
(metal strap / screw band with tension screw / rubber cable protector),
for larger cross-sections up to 70 mm2 available on request ------ ------
Size 1 Size ≥ 2 Note: Cable ties for pump sets of material variants Standard B and Special
on request.
Note: Use 1 cable tie each per cable and per 3 m of riser pipe.
For selection see details and examples on page 111.
“UPA CONTROL” box 3~ / 400 V,
for d.o.l. starting, temperature-compensated, insulating enclosure, with 4
PG cable glands for round cable, 3 immersion electrodes and integrated
selector switch for “Dry running protection” or “Water level control”
operation, as well as with thermal overcurrent relay with phase failure
protection, for motor sizes ...
1~/230 V: 3~/400 V:
------ 0.37 kW 40 980 887 3.5
------ 0.55 kW + 0.75 kW 40 980 889 3.5
------ 1.10 kW + 1.50 kW 40 980 891 3.5
0.37 + 0.55 kW ------ 40 980 893 3.5
0.75 kW 2.20 kW 40 980 895 3.5
1.10 kW 3.00 kW + 3.7 kW 40 980 897 3.5
1.50 kW 40 980 899 3.5
2.2 kW 5.50 kW 40 984 811 3.5
------ 7.50 kW 90 052 649 3.5
------ UMA 150D - 5/21 40 984 811 3.5
------ UMA 150D - 7/21 90 052 649 3.5
------ UMA 150D -- 9/21 90 052 650 3.5
Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode per m 01 046 306 0.051
Automatic control units
Cervomatic EDP 90 053 396 2.2
with G 11/4’’ connection, for a max. flow rate of 12 m3/h,
3
Cervomatic EDP max. flow rate of 12 m /h, a max. operating pressure of 10 bar and a max.
current rating of 10 A,
for 1~ + 3~/ 220 to 240 V and 3~/ 380 to 415 V
(with electric protection from 0 to 10 A, can be set in 0.5 A steps).
90 053 395 1.3
Controlmatic E
with G 11/4’’ connection, for a max. flow rate of 10 m3/h, a max. operating
Controlmatic E pressure of 10 bar and a max. current rating of 10 A,
for 1~ 220 to 240 V
Dry running protection equipment for ...
-- semi-automatic operation (1 relay, 1 pushbutton + 2 electrodes) . . . . . . . 90 009 553 2.0
-- fully automatic operation (1 relay + 3 electrodes) . . . . . . . . . . . . . . . . . . . . 90 009 554 2.0
Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode per m 01 046 306 0.051
Pressure controller, (membrane-type), insulating enclosure . . . . . . . . . . . . . 01 088 101 0.9
1 -- 10 bar, with R 3/8 connection.
103
60 Hz Accessories
Accessories
Description Ident. No. ≈ kg
GR Adapter from threaded end G 11/4’’ to threaded end G 11/2’’ . . . . . . . . . . . 90 052 823 0.5
Material: CrNiMo steel
H
Mode of supply: sealed and screwed tightly into the pump end.
GP
104
60 Hz Accessories
Accessories
Description Ident. No. ≈ kg
Cooling, suction and pressure shroud for vertical and horizontal
installation
Galvanized steel and CrNiMo steel material variants on request. ------ ------
105
60 Hz Accessories
Application Limits
Rated voltage:
-- UN ≤ 1000 V for ex. in wells,
-- UN ≤ 750 V in swimming pools.
Ambient temperature . . . . . t ≤ +50 oC.
Immersion depth . . . . . . . . . ≤ 500 m.
Description / Design
a) Flat cables: b) Round cables:
1) 2)
3-/4-core rubber-sheathed cable. Consisting of finely stranded bare copper conductors, core insulation and outer sheath made
of special rubber compound on EPR basis (ethylene propylene rubber), blue. With BAM 1) certificate, i.e. suitable for permanent
use in drinking water applications.
1) German Federal Institute for Materials Research
Designation (Example)
Flat cable: ZN 1391 - G FL GWT -J 4G25 - Cu-Rubber
Factory standard
Insulation: rubber
FL: flat + RD: round
For drinking water
Earth conductor: “O = without, “- J” = with
Cores (O: “3 x 25”, J: “4 G 25”)
Materials
Dimensions + Weights
Cross-section q in mm2
Type 1.5 2.5 4 6 10 16 25 35 50 70
↕ mm 5.2 + 1 6.1 + 1.5 7.0 + 2 7.6 + 2.2 9.3 + 2.2 11.2 + 2.3 13.0 + 2.5 14.6 + 2.9 17.0 + 3 19.3 + 2.7
$ mm 11.0 + 2 13.2 + 2.3 15.5 + 3.5 17.4 + 3.6 21.5 + 3.5 26.7 + 4.3 31.6 + 3.9 35.5 + 5 42.1 + 4.9 48.4 + 3.6
m kg/m 0.110 0.171 0.252 0.319 0.486 0.750 1.107 1.438 2.054 2.760
↕ mm 5.2 + 1 6.1 + 1.5 ------ 7.6 + 2.2 9.3 + 2.2 11.2 + 2.3 13.0 + 2.5 ------ ------ ------
$ mm 14.5 + 2.7 17.5 + 2.5 ------ 23.5 + 3 29.0 + 3.5 35.0 + 2.4 41.5 + 4.5 ------ ------ ------
m kg/m 0.165 0.237 ------ 0.440 0.704 1.026 1.457 ------ ------ ------
∅ mm 5.3 + 1.1 ------ ------ ------ ------ ------ ------ 13.8 + 3.6 16 + 3.8 ------
m kg/m 0.051 ------ ------ ------ ------ ------ ------ 0.499 0.699 ------
∅ mm 10.0 + 2 12.0 + 1.9 13.9 + 2 15.7 + 2.1 21.1 + 2.1 24.5 + 4.3 29.7 + 4.3 33.3 + 5.5 39.0 + 5.6 44.2 + 5.8
m kg/m 0.180 0.259 0.356 0.475 0.837 1.220 1.770 2.304 3.185 4.364
106
60 Hz Accessories
Imax in A
for cross-section of ... mm2
-- 1 cable:
∆P = ∆U [%]
(cos phi) 2
where ...
L = single cable length [m]
IN = rated current [A]
cos phi = power factor at 4/4 load
q = copper conductor cross-section [mm2]
U = supply voltage [V]
107
60 Hz Accessories
400
U = 460 V
∆U = 3 %
t ≤ + 30 oC
300
Imax = 250 A 70 mm2 in air laid along a surface!
Imax = 99 A 16 mm2
100
90
80 Imax = 74 A 10 mm2
70
60
→
Imax = 53 A 6 mm2
50 ↓ ↓
Imax = 41 A 4.0 mm2
40
20
IN
[A]
10
9
8
7
6
5
↓ ↓
1
10 20 30 40 50 60 70 80 90100 L [m] 200 300 400 500
Example:
a) IN = 68 A, 1 x 16 mm2 , ∆U ≤ 3 % → L ≤ 120 m! b) IN = 68 A, 1 x 25 mm2 , ∆U ≤ 3 % → L ≤ 185 m!
For supply voltages other than 460 V, the cable lengths must be calculated as follows, for ex. ...
U1 = 460 V, L1 = 120 m, U2 = 380 V → L2 = (U2 : U1) x L1, L2 = (380 V : 460 V) x 120 m = 99 m!
For parallel cables the value is doubled to obtain the permissible length.
108
60 Hz Accessories
200
Imax = 171 A 16 mm2
30
→
20
# #
IN
[A]
10
9
8
7
6
5
# #
1
10 20 30 40 50 60 70 80 90100 L [m] 200 300 400 500
Example:
a) IN = 27 A, 2 x 6 mm2, ∆U ≤ 3 % → L ≤ 165 m! b) IN = 27 A, 2 x 10 mm2 , ∆U ≤ 3 % → L ≤ 260 m!
For supply voltages other than 400 V, the cable lengths must be calculated as follows, for ex. ...
U1 = 460 V, L1 = 165 m, U2 = 380 V, → L2 = (U2 : U1) x L1, L2 = (380 V : 460 V) x 165 m = 136 m!
109
60 Hz Accessories
Selection Criteria
Type, number and size of the electric cable, as well as nominal diameter and length of the riser / discharge pipe.
Selection Table
Tie Required length of strap L per cable tie in ¶ ... mm
Electric cable
size m 1) for risers G .../DN ...
Number x core 11/4’’ / 11/2’’ / 2’’/ 21/2’’/ 3’’/ 4’’/ 5’’/ 6’’/ 7’’/ 8’’/ 10’’ 12’’ 14’’ 16’’
Type
dia. in mm2 ---- ¶ kg 32 40 50 65 80 100 125 150 175 200 250 300 350 400
3 x 1.5 4 x 1.5
to to 1 ---- 270 280 320 360 400 450 500 600 -------- -------- -------- -------- -------- --------
3 x 6.0 4 x 6.0
Flat
3 x 10 4 x 10
to to 11 0.01 ---- ---- 350 400 450 550 650 800 950 1100 1300 1500 1700 1900
3 x 70 4 x 70
3 x 1.5 4 x 1.5
to to 1 ---- 270 280 320 360 400 450 500 600 ------ ------ ------ ------ ------ ------
3 x 6.0 4 x 6.0
3 x 10 4 x 10 2 0.08 ---- ---- 350 400 450 550 650 800 950 1100 1300 1500 1700 1900
3 x 16
4 x 16 3a 0.19 ------ ------ 350 400 450 550 650 800 950 1100 1300 1500 1700 1900
3 x 25
3 x 35 4 x 25
3 0.19 ------ ------ ------ 450 500 600 700 850 1000 1150 1350 1550 1750 1950
3 x 50 4 x 35
Round 3 x 70 4 x 50 3b 0.19 ------ ------ ------ 450 500 600 700 850 1000 1150 1350 1550 1750 1950
4 x 70
3 x 95 4 0.55 ------ ------ ------ ------ ------ 650 750 900 1050 1200 1400 1600 1800 2000
4 x 95
3 cables 1 x 50 7 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050
3 cables 1 x 70 8 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050
3 cables 1 x 95 6 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050
3 cables 1 x 120
9 0.6 ------ ------ ------ ------ ------ 700 800 950 1100 1250 1450 1650 1850 2050
3 cables 1 x 150
1) Cable protector (Sizes 11, 2 to 9).
Design
Size 1: Size 11: Sizes 2, 3, 3a, 3b, 4: Sizes 6, 7, 8, 9:
d
b
b
a
c
d
e
c
a
a= Riser
b= Electric cable a = Riser d = Cable protector
c= Rubber strap b = Electric cable e = Screw band with tension screw
d= Plastic stud (2 pcs/cable tie) c = Metal strap (re-usable)
Note:
-- Use 1 cable tie each per cable and per 3 m of riser pipe.
-- If an extension cable with a larger diameter is connected to the standard short motor cable, the cable tie size required for the
larger cable is to be used along the entire cable length.
111
60 Hz Submersible borehole pumps
∅ 1200
[mm]
1000
V >= 0.5 m/s
800
DN 100V ≥ 0.1
600
Example:
Given: UPA 300 - 65/4 + UMA 250D 160/21 and v ≥ 0.5 m/s.
Found: For Q = 250 m3/h (¶ Qopt) the following applies: ⇒ DN ≤ 700 mm.
This means that the requirement for v ≥ 0.5 m/s is met, if the pump set is, for example, installed in a well or cooling shroud of
DN ≤ 700 mm or ≤ 28 inches.