4110XM

CONTROL PANEL

The industry’s most economical six-zone control panel, Honeywell’s 4110XM provides excellent coverage for fire, burglary
and emergency situations. It is an ideal entry-level panel for residential applications, including new builder markets.

FEATURES
• Six programmable zones, three • Keyswitch arming with status • INSTANT and MAXIMUM mode
keypad zone, plus duress indication and tamper protection cancels entry delay
• Zone 5 can be supervised fire using • Test mode checks sounder, • Entry delay eliminated with MAXIMUM
four-wire smoke detectors generates communicator test arming with interior protection on
report; System can be walk tested
• End of line resistor supervision on • Three keypad activated panic zone
all zones for normally open or • Seven user codes consisting
• Entry time: 0, 20, 30 or 45, 60,
closed contacts of one master code and six
90 seconds
secondary codes
• Normal response, 400 msec, on all
• Exit time: Entry time plus 15 seconds
zones, one zone can be 10 msec. • Swinger suppression - ten maximum
number of alarms and trouble • Alarm cut-off time: 4, 8, 12, 16
• Zone types: entry/exit, perimeter,
reports permitted per armed period minutes or no time-out
interior follower, day trouble/night
or unlimited
alarm, 24-hour silent panic, 24-hour • Extra large cabinet with removable
audible panic, 24-hour auxiliary, fire, • Individual bypass by zone door for wiring ease
with and without timeout
• Forced Bypass - single bypass entry
• Interior zone bypassed with STAY for all zones that are faulted Security Dealer Features
and INSTANT functions • Built-in alarm relay, SPST: steady
• Fire alarm sounding turned off by
output for burglary/audible
• Zone restore reporting at sounder single entry of OFF key
emergency and pulsed for fire
time-out if zone restored or at next
• Chime mode on entry/exit and
system disarming • Pre-alarm, trouble and alert sounder
perimeter zones
built into keypads
• Quick arming requires only a two-key
Valuable End-User Features
entry for an arming mode, if enabled.
• Audible Exit Warning
Reports as User 0.
• All keypads have an English language
• Interior zone bypassed with STAY
display and a four-wire connection to
and INSTANT arming
the control
4110XM
CONTROL PANEL

SPECIFICATIONS

Communication • True dial tone detection • Site initiated or remote download


• Split/Dual Reporting from an IBM compatible PC,
• Double pole line seizure
Compass and CIA modem
• Daily, Weekly or Monthly test
• Communication delayed for
• Account takeover protection —
• Touchtone or pulse dial 15 seconds on burglary zone (not
prevents unauthorized takeover
panic or fire zones) if selected
• Formats: of your accounts
Honeywell contact ID • Control low battery report when
• Downloading security with: security
Honeywell 4+2 Express: battery reaches 11.2 -11.6V
code handshake, data encryption,
10 characters/sec. DTMF
• AC power loss report operator access levels to files and
(Touch¬tone) data tone, 1400/2300
functions, date/time stamping with
Hz ACK, 1400 Hz kissoff, checksum
Electrical operator ID
verification Honeywell Low Speed:
• Bell Supervision
10 pulses/sec, 1900 Hz data tone, • Remote download capabilities:
1400 Hz ACK/kissoff • Auxiliary current: 500 mA, 12VDC, Change user codes
Radionics: 20 pulses per second, current limited Enter new program
1800 Hz data tone, 2300 Hz Upload resident control program
• Low battery shutdown:
ACK/kissoff
9.8 - 10.5V Accessories
• 3+1, 4+1, and 4+2 reporting in slow • CE2X - LX2
• Transformer: 16.5VAC, 25VA
speed formats -Code Encryptor LX2
(ADEMCO No. 1321/TF2)
• Dual telephone numbers
• Standby time: seven hours with Keypads
• Back-up reporting: eight attempts 400mA auxiliary load using a • 6150 Fixed English LCD
made to primary and another 12 volt, 4 Ah battery –85mA/40mA
eight attempts to secondary
• Battery charging voltage: 13.8VDC • 6148 Fixed English LCD
telephone number
• Alarm current: 2.0 amps, 12VDC –70mA/30mA
• Expanded reporting:
fuse protected programming
alarms, restorals, bypasses and Agency Listings
trouble by zone; open/close by user • UL Residential Fire, Burglary
Programming
• Hexadecimal reporting • Programmable through keypad in and CSFM
non-volatile EEROM memory
• Four-digit PABX code and
twelve-digit telephone number

ORDERING
4110XM Control Panel

Automation and Control Solutions


Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747 L/4110XM/D
September 2008