CONTROL PANEL
The industry’s most economical six-zone control panel, Honeywell’s 4110XM provides excellent coverage for fire, burglary
and emergency situations. It is an ideal entry-level panel for residential applications, including new builder markets.
FEATURES
• Six programmable zones, three • Keyswitch arming with status • INSTANT and MAXIMUM mode
keypad zone, plus duress indication and tamper protection cancels entry delay
• Zone 5 can be supervised fire using • Test mode checks sounder, • Entry delay eliminated with MAXIMUM
four-wire smoke detectors generates communicator test arming with interior protection on
report; System can be walk tested
• End of line resistor supervision on • Three keypad activated panic zone
all zones for normally open or • Seven user codes consisting
• Entry time: 0, 20, 30 or 45, 60,
closed contacts of one master code and six
90 seconds
secondary codes
• Normal response, 400 msec, on all
• Exit time: Entry time plus 15 seconds
zones, one zone can be 10 msec. • Swinger suppression - ten maximum
number of alarms and trouble • Alarm cut-off time: 4, 8, 12, 16
• Zone types: entry/exit, perimeter,
reports permitted per armed period minutes or no time-out
interior follower, day trouble/night
or unlimited
alarm, 24-hour silent panic, 24-hour • Extra large cabinet with removable
audible panic, 24-hour auxiliary, fire, • Individual bypass by zone door for wiring ease
with and without timeout
• Forced Bypass - single bypass entry
• Interior zone bypassed with STAY for all zones that are faulted Security Dealer Features
and INSTANT functions • Built-in alarm relay, SPST: steady
• Fire alarm sounding turned off by
output for burglary/audible
• Zone restore reporting at sounder single entry of OFF key
emergency and pulsed for fire
time-out if zone restored or at next
• Chime mode on entry/exit and
system disarming • Pre-alarm, trouble and alert sounder
perimeter zones
built into keypads
• Quick arming requires only a two-key
Valuable End-User Features
entry for an arming mode, if enabled.
• Audible Exit Warning
Reports as User 0.
• All keypads have an English language
• Interior zone bypassed with STAY
display and a four-wire connection to
and INSTANT arming
the control
4110XM
CONTROL PANEL
SPECIFICATIONS
ORDERING
4110XM Control Panel