Single point load cell

Max. Capacities:
100kg...300kg

Special features
· OIML-R60 approval
· Off center load compensated
(OIML R76)
· Protection class IP65
(according to EN 60 529)
· 6-wire-technology
· Meets EMC standards
(EN 45 501)

Options on request:
· EEx ia IIC T6 approval

Dimensions (in mm; 1mm = 0.03937 inches)


Cable:
Center of 6-core round cable (6x0.14mm2)
42.5 Platform with PVC--jacket
Wiring code:
Sense -- grey
Sense + green
Type
F. No. plate Excitation + blue
Excitation -- black
Output -- red
87±0.2 Output + white
42.5 Shield connected with load cell budy
Silicone coating Connector:
CE 100F26-6 (Panduit)
Cable length
Recommend. mating connect.: AMP 167 804-4
e.g. cable extension
Panduit MLSS100-04 (straight) or
+0,4
--0,9

MLAS100-04 (hooked)
e.g. pcb connection
Mounting:
Cylindrical screw M8-10.9
Tightening torque: 32Nm
Material:
Aluminum

D.PW24.0e -- 304.24 -- 1050.4 -- Version a -- 23.07.2001


Data sheet D.PW24.0e
Technical data
Type PW24D1 PW24C3
Accuracy class 1) D1 C3
Maximum number of load cell intervals (nLC) 1000 3000
Maximum capacity (Emax) kg 100 150 250 300 100 150 250 300
Minimum LC verification interval (vmin) g 50 100 100 200 20 20 50 50
Maximum platform size mm 600 x 600 600 x 600
Sensitivity (Cn) 2.0 ±0.2 2.0 ±0.2
mV/V
Zero balance 0 ±0.1 0 ±0.1

±0.0700

±0.0933

±0.0700

±0.0933

±0.0280

±0.0186

±0.0350

±0.0233
Temperature effect
on zero balance (TK0)
% of Cn
Temperature effect / 10K
on sensitivity (TKC) 2)
Temperature range:
±0.0350 ±0.0117
+20 ... +40°C [+70 ... +105°F]
±0.0525 ±0.0175
--10 ... +20°C [+15 ... +70°F]
Hysteresis error (dhy) 2) ±0.0500 ±0.0166
Non-linearity (dlin) 2) ±0.0500 ±0.0166
% of Cn
Creep (dcr; dDR) over 30 min. ±0.0500 ±0.0166
Off center load error ±0.10003) ±0.02334)
Input resistance (RLC) 024 ±15 420 ±15
W
Output resistance (R0) 350 ±5 350 ±5
Reference excitation voltage (Uref) 5 5
V
Nominal range of excitation volt. (BU) 1 ... 15 1 ... 15
Insulation resistance (Ris) at 100VDC GW >1 >1
Nominal temperature range (BT) --10 ... +40 --10 ... +40
Service temperature range (Btu) C
°C --10 ... +50 --10 ... +50
Storage temperature range (Btl) --25 ... +70 --25 ... +70
%
Safe load limit (EL) *) 150 150
v. Emax
*) at max. eccentricity mm 150 150
Lateral load limit (Elq), static % 300 300
Breaking load (Ed) of Emax 300 300
Deflection at Emax (snom), approx. mm < 0.6 < 0.6
Weight (G), approx. kg 1.4 1.4
Protection class according to EN60529
IP65 IP65
(IEC529)
Material: Measuring element Aluminum Aluminum
Coating Silicone rubber Silicone rubber
1) According to OIML R60 with PLC = 0.7
2) The data for Non--linearity (dlin), Hysteresis error (dhy) and Temperature effect on sensitivity (TKC) are typical values. The
sum of these data meets the requirements according to OIML R60.
3) Refers to the scale capacity (Max) for 1000d.
The tolerance value corresponds to 70% of the permissible scale error according to OIML R76, Class IIII.
4) Refers to the scale capacity (Max) for 3000d.
The tolerance value corresponds to 70% of the permissible scale error according to OIML R76, Class III.

Hottinger Baldwin Messtechnik GmbH Modifications reserved.


All details describe our products in
Im Tiefen See 45, D--64293 Darmstadt, Germany general form. They are not to be
Tel.: +49 (0)6151 / 803 0; Fax: +49 (0)6151 / 803 9 100 understood as express warranty and do
not constitute any liability whatsoever.

wt 07.01 -- (pdf)
D.PW24.0e -- 304.24 -- 1050.4 -- Version a -- 19.07.2001

Vous aimerez peut-être aussi