Chapter 4

Solver Settings

Introduction to CFX

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-1 Inventory #002598
Solver Settings
Overview Training Manual

• Initialization

• Solver Control

• Output Control

• Solver Manager

Note: This chapter considers solver settings for steady-state simulations.


Settings specific to transient simulation are discussed in a later chapter.

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-2 Inventory #002598
Solver Settings
Initialization Training Manual

• Iterative solution procedures require that all solution variables are


assigned initial values before calculating a solution

• A good initial guess can reduce the solution time

• In some cases a poor initial guess may cause the solver to fail
during the first few iterations

• The initial values can be set in 3 ways:


1. Solver automatically calculates the initial values
2. Initial values are entered by the user
3. Initial values are obtained from a previous solution

• Initial values can be set on a per-domain basis or globally for all


domains
ANSYS, Inc. Proprietary April 28, 2009
© 2009 ANSYS, Inc. All rights reserved. 4-3 Inventory #002598
Solver Settings
Initialization – Setting Initial Values Training Manual

• Insert Global Initialisation


from the toolbar or by right-
clicking on Flow Analysis 1

• Edit each Domain to set initial


values on a per-domain basis
– When both are defined the
domain settings take
precedence
– Solid domain must have
initial conditions set on a per-
domain basis

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-4 Inventory #002598
Solver Settings
Initialization – Setting Initial Values Training Manual

• The Automatic option means that the


CFX-Solver will calculate an initial value
for the solved variable unless a previous
results file is provided
– Will be based on boundary condition
values and domain settings

• The Automatic with Value option means


that the specified value will be used
unless a previous results file is provided
– Can use a constant value or an expression

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-5 Inventory #002598
Solver Settings
Initialization – Using a Previous Solution Training Manual

• To use a previous solution as the


initial guess enable the Initial Values
Specification toggle when launching
the Solver
– You can provide multiple initial values
files
• When simulating a system you can
provide previous solutions for each
component of the system as the initial
guess
• Usually each file would correspond to a
separate region of space
• It is best if domains in the Solver Input
File do not overlap with multiple initial
values files

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-6 Inventory #002598
Solver Settings
Solver Control – Editing Training Manual

• Edit the Solver Control object in the Outline tree

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-7 Inventory #002598
Solver Settings
Solver Control – Options Training Manual

• The Solver Control panel contains


various controls that influence the
behavior of the solver

• These controls are important for the


accuracy of the solution, the stability of
the solver and the length of time it takes
to obtain a solution

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-8 Inventory #002598
Solver Settings
Solver Control – Advection Scheme Training Manual

• The Advection Scheme refers to the way the


advection term in the transport equations is
modeled numerically
– i.e. the term that accounts for bulk fluid motion
– Often the dominant term

Unsteady Advection Diffusion Generation

• Three schemes are available, High


Resolution, Upwind and Specified Blend
– Discussed in more detail next

• There is rarely any reason to change from the


default High Resolution scheme

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-9 Inventory #002598
Solver Settings
Solver Control – Advection Scheme Theory Training Manual

• Solution data is stored at nodes, but variable values are required at


the control volume faces to calculate fluxes

• The upstream nodal values (fup) are interpolated to the integration


points (fip) on the control volume faces using:

fip = fup + bf  r


fip = gradient
– Where f is the variable fup + b f  r is the vector between the
and
upstream node and the integration point
– In other words, the ip value is equal to the upstream value plus a
correction due to the gradient
– b can have values between 0 and 1 …

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-10 Inventory #002598
Solver Settings
Solver Control – Advection Scheme Theory Training Manual

fip = fup + bf  r


Flow is misaligned Theory
with mesh

1
• If b = 0 we get the Upwind advection
scheme, i.e. no correction 0
– This is robust but only first order accurate
– Sometimes useful for initial runs, but
usually not necessary
Upwind Scheme

• The Specified Blend scheme allows you to


specify b between 0 and 1 (i.e. between no
correction up to full correction)
– But this is not guaranteed to be bounded,
b=1.00
meaning that when the correction is
included it can overshoot or undershoot
what is physically possible

• The High Resolution scheme maximizes b High Resolution


throughout the flow domain while keeping Scheme
the solution bounded
ANSYS, Inc. Proprietary April 28, 2009
© 2009 ANSYS, Inc. All rights reserved. 4-11 Inventory #002598
Solver Settings
Solver Control – Turbulence Numerics Training Manual

• Regardless of the Advection Scheme


selection, the Turbulence equations
default to the First Order (Upwind)
scheme
– Usually this is sufficient

• The High Resolution scheme can be


selected for additional accuracy
– Can give better accuracy in boundary
layers on unstructured meshes

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-12 Inventory #002598
Solver Settings
Solver Control – Convergence Control Training Manual

• The Solver will finish when it reaches Max.


Iterations unless convergence is achieved
sooner
– If Max. Iterations is reached you may not have
a converged solution
– Can be useful to set Max. Iterations to a large
number

• When the Solver finishes you should always


check why it finished

• Fluid Timescale Control sets the timescale in


a steady-state simulation …

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-13 Inventory #002598
Solver Settings
Solver Control – Timescale Background Training Manual

• ANSYS CFX employs the so called False Transient Algorithm


– A timescale is used to move the solution towards the final answer

• In a steady-state simulation the timescale provides relaxation of the


equation non-linearities

• A steady-state simulation is a “transient” evolution of the flow from the


initial guess to the steady-state conditions
– Converged solution is independent of the timescale used

Initial Guess
50 iterations
100 iterations
150 iterations

Final Solution

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-14 Inventory #002598
Solver Settings
Solver Control – Timescale Selection Training Manual

• For obtaining successful


convergence, the selection of the
timescale plays an important role

– If the timescale is too large, the


convergence becomes bouncy or
may even lead to the failure of the
Solver

– If the timescale is too small, the


convergence will be very slow and
the solution may not be fully
accurate

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-15 Inventory #002598
Solver Settings
Solver Control – Timescale Selection Training Manual

• For advection dominated flow, a fraction of the fluid residence time is


often a good estimate for the timescale
– A timescale of 1/3 of (Length Scale / Velocity Scale) is often optimal
– May need a smaller timescale for the first few iterations and for complex
physics, transonic flow,…..

• For rotating machines, 1/ ( in rad/s) is a good choice

• For buoyancy driven flows, the timescale should be based on a


function of gravity, thermal expansivity, temperature difference and
length scale (see documentation)

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-16 Inventory #002598
Solver Settings
Solver Control – Timescale Control Training Manual

• Timescale Control can be Auto Timescale,


Physical Timescale or Local Timescale
Factor

• Physical Timescale

– Specify the timescale. Usually a constant but


can also be variable via an expression

– Can often set a better timescale than Auto


Timescale would produce – faster
convergence

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-17 Inventory #002598
Solver Settings
Solver Control – Timescale Control Training Manual

• Auto Timescale
– The Solver calculates a timescale based on
boundary / initial conditions or current solution
and domain length scale

– Use a Conservative or Aggressive estimate for


the domain length scale, or a specified value

– Timescale is re-calculated and updated every


few iterations as the flow field changes

– Can set a Maximum Timescale to provide an


upper limit

– Tends to produce a conservative timescale

– Timescale factor (default = 1) is a multiplier


which can be changed to adjust the
automatically calculated timescale
ANSYS, Inc. Proprietary April 28, 2009
© 2009 ANSYS, Inc. All rights reserved. 4-18 Inventory #002598
Solver Settings
Solver Control – Timescale Control Training Manual

• Local Timescale Factor


– Timescale varies throughout the domain

Local Mesh Length Scale


Local Timescale =
Local Velocity Scale

Smaller Timescale in high


velocity and/or fine mesh regions
– Can accelerate convergence when vastly different local velocity scales exist
• E.g. a jet entering a plenum
– Best used on fairly uniform meshes, since small element will have a small
timescale which can slow convergence
– Local Timescale Factor is a multiplier of the local timescale
– Never use as final solution; always finish off with a constant timescale
ANSYS, Inc. Proprietary April 28, 2009
© 2009 ANSYS, Inc. All rights reserved. 4-19 Inventory #002598
Solver Settings
Solver Control – Convergence Criteria Training Manual

• Convergence Criteria settings determine


when the solution is considered converged
and hence when the Solver will stop
– Assuming Max. Iterations is not reached

• Residuals are a measure of how accurately


the set of equations have been solved
– Since we are iterating towards a solution, we never
get the exact solution to the equations
– Lower residuals mean a more accurate solution to
the set of equations (more on the next slide)
– Do not confuse accurately solving the equations
with overall solution accuracy – the equations may
or may not be a good representation of the true
system!
– Residuals are just one measure of accuracy and
should be combined with other measures:
• Monitor Points (ch. 8) and Imbalances (below)

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-20 Inventory #002598
Solver Settings
Solver Control – Residuals Theory Training Manual

• The continuous governing equations are discretized into a set of linear


equations that can be solved. The set of linear equations can be written in
the form:
[A] [Φ] = [b]

where [A] is the coefficient matrix and [Φ] is the solution variable

• If the equation were solved exactly we would have:

[A] [Φ] - [b] = [0]

• The residual vector [R] is the error in the numerical solution:

[A] [Φ] - [b] = [R]

• Since each control volume has a residual we usually look at the RMS
average or the maximum normalized residual

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-21 Inventory #002598
Solver Settings
Solver Control – Residuals Training Manual

• Residual Type
– MAX: Convergence based on maximum
residual anywhere
– RMS: Convergence based on average
residual from all control volumes

– Root Mean Square = R


i
i
2

• Residual Target
– For reasonable convergence MAX residuals
should be 1.0E-3, RMS should be at least
1.0E-4
– The targets dependent on the accuracy
needed
• Lower values may be needed for greater
accuracy

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-22 Inventory #002598
Solver Settings
Solver Control – Conservation Target Training Manual

• The Conservation Target sets a target for the


global imbalances
Flux In  Flux Out
% Imbalance 
Maximum Flux
• The imbalances measure the overall
conservation of a quantity (mass, momentum,
energy) in the entire flow domain

• Clearly in a converged solution Flux In should equal Flux Out

• It‟s good practice to set a Conservation Target and/or monitor the


imbalances during the run

• When set, the Solver must meet both the Residual and Conservation Target
before stopping (assuming Max. Iterations is not reached)

• Set a target of 0.01 (1%) or less


– Flux In – Flux Out < 1%

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-23 Inventory #002598
Solver Settings
Solver Control – Elapsed Time and Interrupt Control Training Manual

• Elapsed Time Control


– Can specify the maximum wall clock time
for a run
– Solver will stop after this amount of time
regardless of whether it has converged

• Interrupt Control
– Can specify other criteria for stopping
the Solver based on logical CEL
expressions
– When the expression returns true the
solver will stop
• Any value >= 0.5 is true
– Examples
• If temperature exceeds a specified value
if(areaAve(T)@wall>200[C],1,0)
• If mesh quality drops below a specified value in a moving mesh case
– More on logical expressions in the CEL lecture

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-24 Inventory #002598
Solver Settings
Solver Control – Solid Timescale Control Training Manual

• This option is only available when a solid


domain is included in the simulation

• The Solid Timescale should be selected such


that it is MUCH larger than the fluid timescale
(100 times larger is typical)
– the energy equation is usually very stable in
the solid zone
– solid timescales are typically much larger than
fluid timescales

• The fluid timescale is estimated using Length Scale / Velocity Scale

• The solid timescale is automatically calculated as function of the length


scale, thermal conductivity, density and specific heat capacity
– Or you can choose the Physical Timescale option and provide a timescale
directly

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-25 Inventory #002598
Solver Settings
Solver Control – Equation Class Settings Training Manual

• The Equation Class Settings tab is an


advanced option that can be used to
set Solver controls on an equation
specific basis
– Not usually needed
– Will override the controls set on Basic
Settings for the selected equation

• Advanced Options
– Advanced solver control options
– Rarely needed

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-26 Inventory #002598
Solver Settings
Output Controls – Results Training Manual

• The Output Control settings control the output


produced by the Solver
– The Trn Results, Trn Stats and Export tab only apply to
transient simulations and are covered in the Transient
chapter

• The Results tab controls the final .res file


– Generally do not use the Selected Variables (or None!)
option since it probably won‟t contain enough
information to restart the run later
– Output Equation Residuals is useful if you need to
check where convergence problems are occurring
– Extra Output Variables List
contains variables that are not
written to the standard results
file
• E.g. Vorticity

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-27 Inventory #002598
Solver Settings
Output Controls – Backup Training Manual

• The Backup tab controls if and when


backup results files are automatically
written by the Solver

• Recommend for long Solver runs in case


of power failure, network interruptions, etc

• Option:
– Standard: Like a full results file
– Essential: Allows a clean solver restart
– Smallest: Can restart the solver, but
there‟ll be a jump in the residuals
– Selected Variables: Not recommended

• Can also manually request a backup file


from the Solver Manager at any time

Frequency of output can be adjusted

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-28 Inventory #002598
Solver Settings
Output Controls – Monitor Training Manual

• The Monitor tab allows you to create Monitor


Points
– These are used to track values of interest as
the Solver runs

• The Cartesian Coordinates Option is used to


track the value of a variable at a specific X, Y,
Z location

• The Expression Option is used to monitor the


values of a CEL expression
– E.g. Calculate the area average of Cp at the
inlet boundary: areaAve(Cp)@inlet
– E.g. Mass flow of particular fluid through an
outlet: oil.massFlow()@outlet

• In steady-state simulations you should create


monitor points for quantities of interest
– One measure of convergence is when these
values are no longer changing

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-29 Inventory #002598
Solver Settings
Solver Manager Training Manual

• The CFX-Solver Manager is a graphical user interface used to:


– Define a run
– Control the CFX-Solver interactively
– View information about the emerging solution
– Export data

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-30 Inventory #002598
Solver Settings
Solver Manager – Defining a Run Training Manual

• Define a new Solver run

• Solver Input File should be the .def file


– Can also pick .res, .bak or _full.trn files to restart a
previous incomplete run

• To make a physics change and restart a solution,


create a new .def file and provide it as the Solver
Input File then select the .res, .bak or _full.trn file
in the Initial Values Specification section
– If both files have the same physics, this is the same
as picking the .res/.bak/_full.trn file as the input file

• Use Mesh From selects which mesh to use. If the


meshes are identical can use either option,
otherwise:
– If you use the Solver Input File mesh, the Initial
Values solution is interpolated onto the input file
– If you use the Initial Values mesh only the physics
from the Solver Input File is used

• Continue History From carriers over convergence


history and iteration counters
ANSYS, Inc. Proprietary April 28, 2009
© 2009 ANSYS, Inc. All rights reserved. 4-31 Inventory #002598
Solver Settings
Solver Manager – Defining a Parallel Run Training Manual

• By default the Solver will run in serial


– A single solver process runs on the local
machine

• Set the Run Mode to one of the parallel options


to make use of multiple cores/processors
– Requires parallel licenses
– Allows you to divide a large CFD problem into
smaller partitions
• Faster solution times
• Solve larger problems by making use of memory
(RAM) on multiple machines

• The Local Parallel options should be used


when running on a single machine

• The Distributed Parallel options should be


used when running across multiple machines

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-32 Inventory #002598
Solver Settings
Solver Manager – Defining a Parallel Run Training Manual

• Serial

• Local Parallel

• Distributed Parallel

• Different communication methods are available (MPICH2, HP MPI, PVM)


– See documentation “When To Use MPI or PVM” for more details, but HP MPI is
recommended in most cases

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-33 Inventory #002598
Solver Settings
Solver Manager – Define Run Advanced Controls Training Manual

• The Show Advanced Control toggle enables the


Partitioner, Solver and Interpolator tabs

• On the Partitioner tab you can pick different


partitioning algorithms
– Partitioning is always a serial process
– Can be a problem for v.large cases since you
cannot distribute the memory load across multiple
machines
– The default MeTiS algorithm uses more memory
than others, so if you run out of memory use a
different method (see documentation for details)

• Multidomain Option:
– Independent Partitioning: Each domain is
partitioned into n partitions
– Coupled Partitioning: All domains are combined
and then partitioned into n partitions
• There‟s a specific option for Transient Rotor Stator
cases

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-34 Inventory #002598
Solver Settings
Solver Manager – Define Run Advanced Controls Training Manual

• On the Solver tab you can select the Double


Precision option
– The solver will use more significant figures in its
calculations
– Doubles solver memory requirements
– Use when round-off error could be a problem – if
„small‟ variations in a variable are important,
where „small‟ is relative to the global range of
that variable, e.g:
• Many Mesh Motion cases, since the motion is often
small relative to the size of the domain
• Most CHT cases, since thermal conductivity is
vastly different in the fluid and solid
• If you have a wide pressure range, but small
pressure changes are important
– Small values by themselves do not need DP

• The Solver estimates its memory requirements upfront


• Memory Alloc Factor is a multiplier for this estimate
– Use when the solver stops with an “Insufficient Memory Allocated” error

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-35 Inventory #002598
Solver Settings
Solver Manager – Interactive Solver Control Training Manual

• During a solution Edit Run in Progress lets you make changes on the fly
– Models generally cannot be changed, but timescales, BC‟s, etc can

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-36 Inventory #002598
Solver Settings
Solver Manager – Additional Solution Monitors Training Manual

• By default monitor plots


New Monitor
are created showing the
RMS residuals for each
equation solved, plus one
plot for any monitor points
• Right-click to switch
between RMS and MAX
• Additional monitors can be
selected showing:
– Imbalances
– Boundary fluxes (FLOW)
– Boundary forces
• Tangential (viscous) Right-click
• Normal (pressure)
– Source terms …

Monitor Plot .out file

ANSYS, Inc. Proprietary April 28, 2009


© 2009 ANSYS, Inc. All rights reserved. 4-37 Inventory #002598
Solver Settings
Solver Manager – Additional Icons Training Manual

• By dragging the cursor over any icon, the feature


description will appear

Start a new Switch


Simulation Residual Plot
between
Monitor Stop Current RMS and
Finished Run Run MAX

Monitor Run Save Current


in Progress Run
ANSYS, Inc. Proprietary April 28, 2009
© 2009 ANSYS, Inc. All rights reserved. 4-38 Inventory #002598