Vous êtes sur la page 1sur 1

TM

DR. FIXIT PIDICRETE CF BRL WATERPROOFING SOLUTIONS


HIGH RANGE WATER REDUCING SUPER PLASTICISER

CONCRETE ADMIXTURES
DR. FIXIT PIDICRETE CF BRL is a modified Sulfonated METHOD OF APPLICATION:
Naphthalene Formaldehyde based super plasticiser which The correct quantity of DR. FIXIT PIDICRETE CF BRL
helps in achieving high workability and high early strength in should be measured with recommended dispenser &
all grades of concrete. It provides excellent retention of slump should be added to the part of mixing water prior to to
using economical dosages. its addition to wet aggregates - cement mix. The
admixture should not in any time be added to dry
SPECIFICATION MEETS : concrete mix. Always mix concrete constituents along
Complies with IS : 9103 - 1999 and ASTM-C-494-86, Type G with water for min. 3 minutes and then add admixture
to the mix. Mix it for another 2 to 3 minutes for getting
FEATURES & BENEFITS: desired results.
Reduces water cement ratio If water addition is one step DR. FIXIT PIDICRETE CF
Better retention in workability, up to 2 hours depending on BRL should be dispersed directly to the gauging water
the mix design or sand.
Improves workability and makes denser concrete thereby
lowering permeability CLEANING:
Achieves early strength Clean tools & equipments with water.
Helps in reducing cement content for a required strength
PRECAUTION / LIMITATIONS :
AREAS OF APPLICATION: OVERDOSING: accidental over dosing generally extends
Casting of RCC columns, beams, slabs, bridge, decks, the initial setting time & effects the early strength
dams, Slip-forming, water retaining structures and any mass generation. However, the ultimate strength will not be
concreting. impaired.
Pump concreting where the internal friction of the mix is When using DR. FIXIT PIDICRETE CF BRL with an air
reduced to a minimum without any segregation. entraining agent the dose rate of AEA should be
Readymix concreting reduced. It may react with AEA & increase air producing
Specially suitable for concrete roads which require very high efficiency.
slump retention Add DR. FIXIT PIDICRETE CF BRL to concrete mix
Complex reinforced concrete independent of other admixture.
Do not add admixture directly to dry mix.
TECHNICAL INFORMATION : Do not use DR. FIXIT PIDICRETE CF BRL with high
Colour : Dark Brown alumina cement.

PIDICRETE CF BRL
Base : Sulpfonated Napthalene Keep the material above freezing temp, however,
Formaldehyde freezing & subsequent thawing will not harm the
Sp.Gravity : 1.16 + 0.02 at 30 deg C product. Only a thorough stirring is required before use.
Chloride Content : Nil DR. FIXIT PIDICRETE CF BRL is nontoxic &
Solid Content : 35 + 1 noninflammable, any contact with skin should be
PH : 7-8 cleaned with water. If any contact with eyes occur wash
It is always advisable to carry out trial mix to establish the with plenty of clean water & seek medical advice.
exact dosage as per mix design & site condition.

PACKING & STORAGE: NOTE :


CC-DF-PIDI BRL-FLR-ENG-01/07

We recommend that before using our products in full scale


HDPE carbuoy of 225 lit. Store in cool dry place, free from production, the customer should make his own tests to determine
frost in original sealed containers. the suitability of the products for his own purpose under his
operating conditions. As the circumstances under which our
products are stored, handled and used, are beyond our control,
SHELF LIFE: we cannot assume any responsibility for their use by the
customer.
12 months from the date of manufacture in a properly packed
& stored container.

Pidilite Industries Limited


Construction Chemicals Division p r o v i d e d i n g o o d f a i t h & m e a n t t o s e r v e o n l y a s a g e n e r a l g u i d e l i n e d u r i n g u s a g e . U s e r s a r e
advised to carry out tests & take trials to ensure on the suitability of products meeting their
Ramkrishna Mandir Road Post Box No. 17411 requirement prior to full scale usage of our products. Since the correct identification of the
Andheri (E) Mumbai 400059 INDIA p r o b l e m s , q u a l i t y o f o t h e r m a t e r i a l s u s e d a n d o n - s i t e w o r k m a n s h i p a r e f a c t o r s b e y o n d o u r
Tel +91-22-2835 7000 Fax +91-22-2835 7008 control, there are no expressed or implied guarantee / warranty as to the results obtained. The
Company does not assume any liability or any consequential damage for unsatisfactory results,
website www.doctor-fixit.com E-mail drfixit@pidilite.com arising from the use of our products.