1 Protection of software features (codeword) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Codeword variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Codew description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.5 Generation (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.6 Relevant AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Alternate routing on error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1.1 Usage of the feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1.2 Main goals for the alternate routing destination numbers in
respect to OOS scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.1.3 Usage of alternate routing destination numbers . . . . . . . . . . . . . . . . . . . . . . 17
2.1.4 Subscriber number supplementation (parameter EXTNO) . . . . . . . . . . . . . . 19
2.2 User interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.1 Examples for usage the alternate routing on error in different
OOS scenarios. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.1.1 Called subscribers (A,B,C,D,E of one source group), are not reachable,
because of device/board errors.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.1.2 Called subscriber is not reachable, because deactivated via AMO with
additional request for alternate routing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.2.1.3 Called HFA IP phones (A,B) are not reachable, because of IP errors,
they moved their logon location from HiPath 4000 to HiPath 3000.. . . . . . . . 30
2.2.1.4 Called subscribers (A,B) in its APs are in an APE situation to AP of the
calling device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
2.3 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2.3.1 Additional control mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2.3.2 General plausibility information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

1
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features

2.3.3 Special restriction information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41


2.3.4 Implausible conditions for supplementation . . . . . . . . . . . . . . . . . . . . . . . . . 42
2.3.5 Plausibility of alternate routing destination numbers . . . . . . . . . . . . . . . . . . . 44
2.3.6 Output of Advisory messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
2.3.7 HiPath 4000 Assistant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
2.3.8 Realization via AMO: AMO or AMO Batch> . . . . . . . . . . . . . . . . . . . . . . . . . 48
2.4 Relevant AMOs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
3 Smart Card application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.2 User interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3.3 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3.4 AMO usage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
3.5 Relevant AMOs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4 HG3550V2.0 WAML-replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.2 SCN-LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
4.2.1 Configuring the HiPath 4000 V2.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.2.1.1 Adding the STMI2-IGW board and configuring the board data . . . . . . . . . . . 58
4.2.1.2 Configuring the HG3550 V2.0 LAN circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.2.2 Configuring UBA in HiPath 4000 Assistant . . . . . . . . . . . . . . . . . . . . . . . . . . 61
4.2.3 Configuring the Gateway HG3550 V2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4.2.3.1 Installing XML30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4.2.3.2 Establish connection to the HG3550 V2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4.2.3.3 Checking the LAN1 interface settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4.2.3.4 Configuring the LAN 2 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.2.3.5 Setting the WAML call number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4.2.3.6 Configuring PSTN Peer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4.2.3.7 Setting the calling number of the peer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
4.2.3.8 Save board data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
4.2.4 Configuration of the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.2.5 Checking the VPN address and PPP1 settings . . . . . . . . . . . . . . . . . . . . . . 78
4.2.6 Adding S0 subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
4.2.7 Starting the dial-up connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
4.2.8 Adding a “Route add” on the PC (DOS-cmd) . . . . . . . . . . . . . . . . . . . . . . . . 80
4.2.9 Getting access to the HiPath 4000 Assistant . . . . . . . . . . . . . . . . . . . . . . . . 81
5 AMO authorizations in the HiPath 4000 V2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
5.1 ADP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
5.2 CC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
5.3 Dropped AMOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
6 Extended features and AMO changes in the
HiPath 4000 V2.0 94
6.1 AMOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
6.2 CLIP for analog subscribers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
6.3 Integrated features without any AMO control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

2
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens

1 Protection of software features (codeword)

1.1 Feature description


Features are sold in feature packages. Each package is allocated a marketing value. The fea-
ture quantities purchased by a customer are encrypted as an alphanumeric "codeword."
The new hardware, HiPath 4000 V2, features a SIM card on the DSCXL board (ADP). The don-
gle used for existing hardware is upwards compatible. However, if the system is upgraded to
Hipath 4000 V2.0 then a new codeword has to be installed.

New hardware: Old hardware:


SIM card on the DSCXL board (ADP) Dongle for existing systems

The dongle or the SIM card and the codeword "tell" the system which feature packages and
quantities were purchased by the customer. When the system is configured, a special plausi-
bility check is used to ensure that the configuration data corresponds to the purchased features
and quantities.

3
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features

PNE

ComScendo CC-AP for AP Emergency

Remote Survivability Cordless E

Voice com-
Entry Agent
pression IP
CODEWORD

Protection of software features

1.2 Codeword variants

In HiPath 4000 V2.0 and later, the CODEWRD will feature four variants:
1. Normal mode:
This is the approved operating mode as implemented in HiPath 1.0. In normal mode, a
codeword and licenses are requested for all relevant licenses in the database.
2. Trial mode:
This feature introduces a time-limited trial mode. When you activate trial mode, you can
skip the license restrictions that are temporarily displayed. During this time, the AMOs work
as if unrestricted licenses were available except that an advisory message is sent to the
users if license restriction violations occur.
3. Emergency mode:
The system activates the Emergency mode, in case of special situations.
Special situations are:
Validity of the Codeword is expired;
Dongle resp. SIM card is missing;
Codeword is missing;
Dongle resp. SIM card does not match to Codeword;

4
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens

Components without licence and not marked as LICMARK


In the Emergency mode the AMO execution is blocked in the SWU. The only AMOs that
can be executed are the AMO CODEW / DATE.
4. Escalated Emergency mode:
The feature triggers an additional system operation restriction (it blocks the FEASU fea-
ture) when the system is in escalation mode for an extended period of time. This restriction
is known as escalation of the Emergency mode.

CODEW variants with dongle in HiPath 4000 V2.0


The HiPath 4000 V1.0 operating mode is maintained if the old hardware is used with a dongle.
However, you must download a new codeword if you migrate to HiPath 4000 V2.0.

TYPE Description Dongle Sim Card


TYPE 1 (Customer) standard: 2 x Test mode each for 60 days X X
( then a new Codeword is required)
TYPE 2 (Special) Via LMT (Licence Mangement Tool)with a time X X
limit longer than 60 Days
Via LMT(Licence Management Tool)without a X X
time limit

● In a network the network codeword from the Hipath 4000 Manager (LMT) is used.
The original Codeword must be added previously in the system.
The Network codeword then overwites the Codeword on a daily basis. If this does not hap-
pen then a 60 day test mode begins.
● The 30 Day Service-Dongle will no longer be given in Hipath4000 V2.0.
● The Type 2 codeword will only be given in special cases.(applied for as an extra).
● The creation date is coded in the Codeword and is stored in the database, when the Code-
word is added in the system. The try to add an older Codeword is blocked in this way.

5
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features

1.3 Codew description

Unit Description AMOs Parameter


COMSCENDO Counting/marketing ACSU ACTYPE=AC4/ACW2Q/ACW-
per configured B channel/ana- MQ
log channel to: BCSU TYPE=SIGNOFF
– station (optiset = 1 B chan- RCSU RECAPL=ACDR/ACDMUS/
nel; optiset E or optiPoint 500 HMUSIC
... with adapter = 2 B chan-
nels; optiip = 1 B channel, but SBCSU DVCFIG=
ANAFAX/ANADTE/ANADEV/
max. 2 B channels per Up0E)
FAX/DTE/OPTIP500/OP-
or attendant console
TISET/S0PP/S2PP/SET600/
OPTIIP
SCSU DVCFIG=ANATE/ANATECM/
AUXDIGI
SSC TYPE=GENANS/MSGR/EX-
TANN/CC/VMXMWI
SXSU ART=OPTIERW
– Trunk or tie TACSU DEVTYPE=TC/TC1/TC2/NW/
(including ATM Networking) TT/TT1/TT2/TT3/TT4
TDCSU DEV=S0COD/S0CONN/
S1COD/S1CONN/S1PVC/
S1SVC/LAN/S1PVCCO/
S2COD/S2CONN/S2PVC/
S2SVC/S2PVCCO/VCCOD/
VCCONN/HG3550/CDG-
CONN/CDGCOD/30/ATMS-
VC/ATMPVC3/ATMPVC7/
ATMPVC15/ATMPVC23/
ATMPVC2X/ATMPVC30/
ATMPVCCO
TSCSU DEV=CC/CCM/ANS/RA/RAS/
DICT/SPKR/DOOR
CORDLESS E Counting/marketing of the acti- SBCSU DVCFIG=BASE
vation license per B channel (for
example SLC16 to base station)
irrespective of the operating
software

6
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens

Unit Description AMOs Parameter


PNE Counting/marketing per VPN B TDCSU DEV=S2CONN
channel configured from/to the
board with PNEDIUS2 line type
(use the AMO BGDAT to check
the line type of a board)
HIPATH PRO- Counting/marketing per active AGENT AGTID=<number>
CENTER ENTRY (logged in) agent
AGENT
HIPATH AP Counting the IPDA survivability APRT CONF=ROUTER/AP
REMOTE remote shelves for connections
SURVIVABILITY over ISDN (ID9206)
(AMO SIPCO parameter SURV-
NET)
CC-AP FOR Counting/marketing per CC con- APESU DATA=CCAP
AP EMERGEN- figured for AP Emergency
CY

7
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features

1.4 Service information


● The counters bear no relationship to the feature dimensioning values administered with the
AMO DIMSU.
● For the purposes of software feature protection, "ComScendo" is the equivalent of "station"
for the following components:
– Optiset E
– optiPoint 500 / optiPoint 400 / optiPoint 410
– ANATE
– ANATECM
– AUXDIGI
– Signed off TSI instead of signed off station
– PP (all S0/S2)
– FBUS (all call numbers)
● The dongle or the SIM card is immediately activated on startup.
● The validity of a codeword may be limited to a specific period. It is calculated in days from
the creation date.
● The expiry date is shown after each LOGON command or after the initial ADD command.
You can also check the date with the DISPLAY-CODEW command.
● A new codeword is needed every time the purchased quantity is expanded.
(Except "HIPATH AP VOICE COMPRESSION IP" where only the coding is dynamically
changed (from G.729 to G.711) when the limit is reached.)
The purchased quantity can be temporarily expanded in trial mode (see Section 1.2).
● An installed codeword only can be replaced by a new one. The creation date is saved in
the codeword; the serial number is used for information purposes only.
● The codeword can be changed with the codeword tool.
● The hardware ID and codeword must match.
● In order to enter a codeword the date of the system must be valid.
● In the event of contractual violation, the user interface is disabled and you are prevented
from starting any more SWU AMOs (for configuration).
● If the system prevents access although the codeword and dongle are valid, you can acti-
vate the dongle with the following actions: unplug/plug in the dongle, enable line8 or per-
form an A1 soft restart.

8
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens

● Further information on the AMO CODEW can be found in the AMO description in the
service manual.

1.5 Generation (example)


● Add a codeword (dongle or SIM card must be inserted):
ADD-CODEW:CODEW1=
W1RAZWX6HPK8HS5G39TKV6X9MKVAM9ENERJTVTZBDX34KFNHRUTP4GU1EC132N93,
CODEW2=LJJ9MKK381DASTYEZNNU67366HMWAM33VVKKRKG7UHTDUGFWJN2PBBREGX;

● Display counters for purchased quantities / configured quantities:

1. Customer dongle / SIM (TYPE 1 - codeword)

DISPLAY-CODEW;
H500: AMO CODEW STARDED

SALES UNIT COUNTERS


===================

CODEWORD: AFTKSB3CJYN4LKZN7GNWZH8TXH63M29A5GA2L2JN261LGKEA8CPHLZV5UGKHVPHP
XGRZDWDF83BG6BLE2U6LSP8GYS8VY5NADW88BUAE6RA58HXMD2N99TJSC9
VERSION : H205
SERIAL NUMBER: 7
HARDWARE ID : C6EB8F3B
ENTRY DATE : 22.02.2004
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 3706

+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | 976 | 913 | 63 | |

9
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features

| CORDLESS E | 0 | 0 | 0 | |
| PNE | 0 | 0 | 0 | |
| HIPATH PROCENTER ENTRY AGENT | 0 | 0 | 0 | |
| SIGNALING SURVIVABILITY | 0 | 0 | 0 | |
| CC-AP FOR AP EMERGENCY | 0 | 0 | 0 | |
+---------------------------------------------+-------+-------+-------+-------+
H07: THE TEST MODE IS AVAILABLE (ANOTHER) 2 TIMES.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU


DISPLAY COMPLETED;

2. Dongle / SIM with TYPE 2 - codeword

DISPLAY-CODEW;
DISPLAY-CODEW;
H500: AMO CODEW STARTED

SALES UNIT COUNTERS


===================

CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72
R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R
VERSION : H205
SERIAL NUMBER: 0
HARDWARE ID : 7ED439FB
ENTRY DATE : 07.01.2004
VALID UNTIL : 17.12.2005
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 0

+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+

10
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens

| COMSCENDO | | 110 | | |
| CORDLESS E | | 0 | | |
| PNE | | 0 | | |
| HIPATH PROCENTER ENTRY AGENT | | 0 | | |
| SIGNALING SURVIVABILITY | | 0 | | |
| CC-AP FOR AP EMERGENCY | | 0 | | |
+---------------------------------------------+-------+-------+-------+-------+
H12: CURRENT CODEWORD IS A TYPE 2 CODEWORD.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU


DISPLAY COMPLETED;

Trial mode
The purchased quantity can be temporarily expanded with trial mode.
Trial mode is activated with CHANGE-CODEW. Utilization is not unlimited (maximum number
specified in codeword, generally 2) and has a maximum utilization time (generally 30 days).
SWU administration is not disabled even if license violation is shown in trial mode ("!!!!!" in the
"FREE" column). A mark that can be displaced with the AMO SDSU is applied to elements that
exceed the license limit (stations, trunks, etc.). The number of units marked is also displayed in
the AMO CODEW.
Trial mode is automatically terminated if not manually deactivated within the maximum time lim-
it. When this happens, marked elements are disabled for security reasons and can only be en-
abled if an appropriate codeword is set up.
No elements are marked or disabled for the features HIPATH PROCENTER ENTRY AGENT
and HIPATH AP VOICE COMPRESSION IP. However, when trial mode ends, no agents above
and beyond the license limits can log on and compressed connections cannot be set up.
Trial mode does not apply to the features HIPATH AP REMOTE SURVIVABILITY and CC-AP
FOR AP EMERGENCY. The codeword’s license limit cannot be exceeded here.
● Activate trial mode:
CHANGE-CODEW:TRIAL=YES;
....(activated after consultation)

● Administration above and beyond the quantities purchased:


ADD-SCSU:STNO=4711,DVCFIG=ANATE;

11
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features

● Display Codeword the test mode is expired:


DISPLAY-CODEW;
DISP-CODEW;
H500: AMO CODEW STARTED

SALES UNIT COUNTERS


===================

CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72
R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R
VERSION : H205
SERIAL NUMBER: 0
HARDWARE ID : 7ED439FB
ENTRY DATE : 18.12.2003
VALID UNTIL : 17.12.2004
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 0

+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | 110 | 110 | !!!!! | 1 |
| CORDLESS E | | 0 | | |
| PNE | | 0 | | |
| HIPATH PROCENTER ENTRY AGENT | | 0 | | |
| SIGNALING SURVIVABILITY | | 0 | | |
| CC-AP FOR AP EMERGENCY | | 0 | | |
+---------------------------------------------+-------+-------+-------+-------+
H12: THE TEST MODE IS AVAILABLE (ANOTHER) ONCE.

AMO-CODEW-111 CODEWORD FOR ADMINISTRATION LOCK IN SWU


DISPLAY COMPLETED;

12
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens

DISPLAY-SDSU:STATUS=LICMARK,TYPE=PEN,LEVEL=PER3;

....(a component is marked if it was installed with the purchased


quantities configured and the system is being operated in trial mode.)

DISPLAY-SDSU:STATUS=LICBLOCK,TYPE=PEN,LEVEL=PER3;
....(specifies the stations disabled on account of license violation
when the trial mode expired.)

13
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features

1.6 Relevant AMO


AMO Parameter Sprache/ Beschreibung/ Description
Language
EINR-CODEW CODEW1 d Erster Teil des Codewortes
CODEW2 d Zweiter Teil des Codewortes
ADD-CODEW CODEW1 e First part of codeword
CODEW2 e Second part of codeword
AE-CODEW TESTMOD d Testmodus ein/ausschalten
CHANGE-CODEW TRIAL e Activate/deactivate trial mode
AB-SDSU LICMARK d Markierte Lizenz (im Testmodus)
LICBLOCK d Gesperrte Lizenez (Testmodus abgelau-
fen)
DISP-SDSU LICMARK e Marked License (in testmode)
LICBLOCK e Blocked License (testmode expired)

14
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

2 Alternate routing on error

2.1 Feature description

2.1.1 Usage of the feature


This feature provides an additional possibility to reach an alternate destination, if the called
subscriber/ personal attendant/ subscribers of a source group is/are in an out_of_service
(OOS) state.
The feature performs a new kind of alternate routing mechanism, using new predefined alter-
nate routing destination numbers, which can be subscriber-individual or source group related.
In some cases (see below), new authorizations will be validated.
In total, four different OOS scenarios of the called subscriber/ personal attendant/ subscribers
of a source group will be handled.
1. The called subscriber/ personal attendant/ subscribers of a source group is/are OOS, be-
cause of a device/ board error.
(no additional authorization (SDAT) necessary)
2. The called subscriber/ personal attendant is OOS because switched off by AMO.
(Authorization (SDAT) necessary for doing alternate routing when manual switched off by
AMO)
3. The called HFA IP phone is in an OOS state and has logged on to a Hipath 3000 because
of IP errors.
(authorization necessary to move logon from HiPath 4000 to HiPath 3000)
4. The access point (AP) of the called subscriber is in an Access Point Emergency (APE) si-
tuation in relation to the AP of the calling device.
(no additional authorization necessary)
Normally, alternate routing will be done only once for a call. In case of an alternate routing be-
cause of APE, it might be necessary to execute another alternate routing again for one of the
other three mentioned OOS scenarios.
The reason why is, that in kind of APE, in the AP of the calling device, it can not be verified for
sure, whether the called subscriber in the target AP is in a seizable condition.
Because of this consideration, it is possible to administer two types of alternate routing desti-
nation numbers (OOS and APE) for a subscriber or a whole source group with different alter-
nate destinations.

15
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

2.1.2 Main goals for the alternate routing destination numbers in


respect to OOS scenario
● Device/ board error
The goal is, to reach the called subscriber either with its mobile phone number, with an al-
ternate number, via PSM or to lead the call to attendant, voice mail, phonemail or some-
thing else.

● Manual deactivated (by AMO) with activated authorization for alternate routing
If subscribers are deactivated manualy by AMO command, alternate routing will only be
performed, if the subscribers are authorized for requesting alternate routing when called
after a manual deactivation.
The goal is identical as for device/ board errors.

● Logged off HFA IP phones.


Authorized HFA IP phones can move their logon location from HiPath 4000 to HiPath 3000
in case of IP errors.
The goal is, to reach these HFA IP phones in their new logon location via public trunk ac-
cess under their individual (modified) extension numbers.

● APE situation between APs of calling device and called subscriber/ personal atten-
dant.
In case of an APE situation between APs of calling device and called subscriber/
personal_attendant, the involved APs act as single switches.
The goal is, to reach the called subscriber in its AP via public trunk access. As a precondi-
tion, a public trunk access has to be administered between the related APs with routing
elements without internal rerouting possibilities.
Attention:
7 Routing elements, that are defined as with "internal rerouting", will not be
used for alternate routing on error in general.

16
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

2.1.3 Usage of alternate routing destination numbers


You can administer an alternate routing destination number Either a subscriber individual alter-
nate routing destination number for one subscriber ,or a source group related alternate routing
destination number for a whole source group of related subscribers can be configured.
In certain OOS scenarios, it might be a requirement to confine to source group related alternate
routing destination numbers,in order not tro waste memory.
It is possible to administer a source group related alternate routing destination number either
as a complete number (EXTNO = 0) or as a incomplete number (EXTNO > 0), you also have
the possibility to reach subscriber individual destinations with the supplementation. request
(EXTNO > 0).
A supplementation will be done at time of alternate routing execution by call processing with
the administered length (EXTNO) of the called subscribers extension number.
If you administer both kinds, and the numbers are different, the subscriber individual alternate
routing destination numbers will be used with higher priority than the source group related al-
ternate routing destination numbers. With this design, you can treat special subscribers (vips)
different than the rest of subscribers of a source group.
In case of usage, the alternate routing destination number will be checked for being usable to
reach an alternate destination successfully. If it is not possible, to reach an alternate destination
with the subscriber individual alternate number, another attempt will be done with the source
group related alternate routing destination number.

17
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

Depending of the OOS scenario (1 --> 4) the alternate routing destination numbers will be
checked for usage in the following hierarchical manner:
● OOS because device/board error
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
● OOS because manual deactivated with activated authorization for alternate routing
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
● OOS of logged off HFA IP phones with activated authorization for move logon
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
● OOS because of APE situation between APs of called subscriber and calling device
– subscriber individual alternate routing destination number for APE
– source group related alternate routing destination number for APE
If the called subscriber is not a HFA IP phone with the activated authorization for move
logon, 2 additional attempts will be done
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS

Device / board error Manual deactivated Moved logon AP Emergency


subscriber individual subscriber individual subscriber individual subscriber individual
(OOS) (OOS) (OOS) (APE)
Source Group related Source Group related Source Group related Source Group related
(OOS) (OOS) (OOS) (APE)
subscriber individual
(OOS)
Source Group related
(OOS)

18
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

2.1.4 Subscriber number supplementation (parameter EXTNO)


Subscriber number suplementation is administered by AMO APRT,branch ALTERR
If you administer the source group related alternate routing destination number as a complete
number, you have to set the parameter EXTNO = 0;
If you administer the source group related alternate routing destination number as a incomplete
number, you have to set the parameter EXTNO to the number of the called subscribers digits,
that are requested for supplementation.
The plausibility of a digit supplementation (design and usage) depends on the WABE result of
the alternate routing destination number (source group related ), as well as the alternate routing
type.
The plausibility checks of the AMO APRT allow the input of EXTNO > 0 only for those alternate
routing destination numbers, that do not lead to WABE result = station. But there are many
other possibilities that are not restricted by the AMO, but cannot be executed at the time of usa-
ge for special alternate routing scenarios.
● Usage of supplementation for APE
If you want to reach the subscribers, that are in APE situations, via public trunk loop in their
own APs under their individual subscriber numbers, you must administer a source group
related incomplete alternate routing destination number for type = APE, that contains a
trunk access code for going public network and a incoming trunk access code to reach the
APs, where the subscribers are located in.
The missing subscribers extension numbers will be supplemented at time of call execution
by call processing.
You have to administer, how many digits of the subscribers extension numbers should be
used for supplementation with setting the parameter EXTNO > 0.
In this example, it is obvious, that EXTNO has to be set to the length of the subscribers
extension numbers.
If you set the parameter EXTNO bigger than the length of the subscribers extension num-
bers, it is tolerated and will be decremented to the real length.
If you set the parameter EXTNO smaller than the length of the subscribers extension num-
bers, this alternate routing destination number can not be used for that case.

19
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

Example 1:
Exit Code = 0
Outgoing public trunk access = 0004989
Number (subscriber_A) = 54321
Administered source group related alternate routing number = 0004989-722
EXTNO = 5 --> supplementation done / result = 0004989-722-54321
EXTNO = 6 --> supplementation done / result = 0004989-722-54321
EXTNO = 4 --> supplementation not possible
EXTNO = 0 --> supplementation not requested / the number 0004989722 do not
lead to a valid destination, but neither by AMO nor at time
of usage, this can be verified.

● Usage of supplementation for OOS (device/ board error or deactivated by AMO)


If you want to reach the subscribers, that are in OOS situation, with searching via PSM un-
der their individual search numbers, you must administer a source group related alternate
routing destination number for type = OOS, that contains the PSM access code.
The missing subscribers extension numbers will be supplemented at time of call execution
by call processing.
You have to administer, how many digits of the subscribers extension numbers should be
used for supplementation with setting the parameter EXTNO > 0.
If the PSM is designed with search length = 0, the parameter EXTNO has to be set to the
length of the called subscriber numbers.
If the PSM is designed with search length = x, the parameter EXTNO has to be set to that
value (x). The normal situation is, that the search length is smaller than the length of called
subscribers. In this case, the supplementation result leads to a cut search number. The cut-
ting will be done from right hand side.

20
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

Example 2:
Paging access code = #77
Number (subscriber_A) = 54321
Administered source group related alternate routing number = #77
Search length = 3
EXTNO = 3 --> supplementation done / result = #77-543
EXTNO = 4 --> supplementation done / result = #77-543
EXTNO = 2 --> supplementation not possible
EXTNO = 0 --> supplementation not requested / invalid

Example 3:
Paging access code = #77
Number (subscriber_A) = 54321
Administered source group related alternate routing number = #77
Search length = 0
Source group related alternate routing number = #77
EXTNO = 5 --> supplementation done / result = #77-54321
EXTNO = 6 --> supplementation done / result = #77-54321
EXTNO = 2 --> supplementation not possible
EXTNO = 0 --> supplementation not requested / invalid

● Usage of supplementation for OOS in case of moved logon


If you want to reach the HFA IP phones, that have moved their logon location from HiPath
4000 to HiPath 3000 in their new logon switch under their individual extension number, you
have to administer a source group related incomplete alternate routing destination number
for type = OOS, that contains a trunk access code for outgoing public network and an in-
coming trunk access code, to reach the HiPath 3000.
The missing subscriber extension numbers will be supplemented at time of call execution
by Call processing.
You have to administer, how many digits of the subscribers extension numbers should be
used for supplementation with setting the parameter EXTNO > 0.

21
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

It may be possible, that the HiPath 3000 works with a different number scheme than the
HiPath 4000.
If the HFA IP phone extension numbers are identically in both switches, you have to set the
parameter EXTNO to the identical extension number length of the HFA IP phones.
If the HFA IP phone extension numbers in the HiPath 3000 are smaller than in the HiPath
4000 (see example 4), you have to set the parameter EXTNO to the smaller HFA IP phone
extension number length. in HiPath 3000. The later performed supplementation then will
cut the HFA IP phone extension numbers from left hand side on.
If the HFA IP phone extension numbers in the HiPath 3000 are bigger than in the HiPath
4000 (see example 5), you have to set the parameter EXTNO to the length of the HFA IP
phone extension number in the HiPath 4000. As the extension numbers in HiPath 3000
starts with an additional digit (9), you must add this as a prefix to the source group related
alternate routing number.
Example 4:
Outgoing public trunk access = 0004989,
Incoming trunk access for HiPath 3000 = 865
Number (HFA IP phone_A in HiPath 4000) = 54321
Number (HFA IP phone_A in HiPath 3000) = 4321
Administered source group related alternate routing number = 0004989-865
EXTNO = 4 --> supplementation done / result = 0004989-865-4321
EXTNO = 5 --> supplementation done / result = 0004989-865-54321
In HiPath 3000 -, the correct HFA IP phone can not be reached.
No kind of syntax check can avoid this malfunction.
EXTNO = 3 --> supplementation done / result = 000498986-5321
In HiPath 3000 -, the correct subscriber can not be reached.
No kind of syntax check can avoid this malfunction.
EXTNO = 0 --> supplementation is not requested / invalid

22
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

Example 5:
Outgoing public trunk access = 0004989,
Incoming trunk access for HiPath 3000 = 865
Number (HFA IP phone_A in HiPath 4000) = 54321
Number (HFA IP phone in HiPath 3000) = 9-54321
Administered source group related alternate routing number = 0004989-865-9

EXTNO = 4 --> supplementation possible / result = 0004989-865-9-4321


In HiPath 3000, the correct subscriber can not be reached
No kind of syntax check can avoid this malfunction.
EXTNO = 5 --> supplementation done / result = 0004989-865-9-54321
EXTNO = 6 --> supplementation done / result = 0004989-865-9-54321
EXTNO = 0 --> supplementation is not requested / invalid

23
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

2.2 User interface

2.2.1 Examples for usage the alternate routing on error in different


OOS scenarios
Make sure, that the maximum number of individual alternate routing destination numbers is big
enough, otherwise increase the maximum number value by AMO DIMSU.
ADD-DIMSU:TYPE=USER,ALTROUT=<new_value>;

2.2.1.1 Called subscribers (A,B,C,D,E of one source group), are not reachable,
because of device/board errors.
● What are the main goals?
Calling a subscriber specific individual alternate routing destination number (mobile phone
number)
Calling a general destination like voicemail or attendant.

● What is possible?
The alternate routing number can be designed to reach any other destination.
If the alternate routing destination number leads to a outgoing trunk access, only those rou-
te elements will be used for alternate routing, that are defined as with "no internal rerou-
ting".

24
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

7100 017nnn..nnn
ISDN

STN-A
OOS-NO =
0017nnn..nnn
STN-F
7101 NO = 4444444

Paging
STN-B NO = #17
OOS-NO =
00303864444444

ATND = 99
STN-C

STN-D

Source -Grp = 3
ALT-NO = 99
STN-G
NO = 5555

ATNDIND=
7199 Source -Group = 2
ALT-NO = #17
ATNDIND with EXTNO
OOS-NO = 5555

25
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

● AMO usage
– Calls to subscriber_A should be alternate routed to a mobile phone number
017nn...nn. Calls to subscriber_B should be alternate routed to a national public num-
ber subscriber_F
For routing type = OOS, you must define a subscriber individual alternating routing desti-
nation number for subscriber_A:
CHANGE-SDAT:STNO=7100,TYPE=DATA1,STNOOOS=<0017nnn...nnn)
For routing type = OOS, you must define a subscriber individual alternate routing destina-
tion number for subscriber_B:
CHANGE-SDAT:STNO=7101,TYPE=DATA1,STNOOOS=00303684444444
If the Redirecting number has to be send to the Carrier, the COT parameter R261 is to be
set on the trunk:
CHANGE-COT:COTNO=xxx,COTTYPE=COTADD,PAR=R261;

– Calls to subscriber_C and subscriber_D of the related source group 3, should be al-
ternate routed to the attendant.
For the related source group, you can define a source group related complete alternate
routing destination number for routing type = OOS:
ADD-APRT:TYPE=ALTERR,SCRGRP=3,ALRTYPE=OOS,ALTRTNR=99;

– Calls to all subscribers of source group = 2 should be alternate routed to Paging sys-
tem.
It will be assumed, that the Paging system works with LENGTH_SEARCH_NO = 0.
For routing type = OOS, you must define a source group related incomplete alternate rout-
ing destination number for that source group 2, the called subscribers are members of.
As for every subscriber an individual search number is requested, the alternate routing
destination number must be a incomplete number containing only the access code for
PSM.
You must set the number of the supplemented digits (parameter EXTNO) equal the number
length of subscribers extension number.
ADD-APRT:TYPE=ALTERR,SRCGRP=2,ALRTYPE=OOS,ALTRTNR=#17,EXTNO=4;
If the Paging system works with length search no = x (1-6), you must administer the param-
eter
EXTNO = <length_search_no>.

26
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

– Private calls for the attendant console 7199 should be alternate routed to to
subscriber_G.
For routing type = OOS, you must define a subscriber individual alternate routing destina-
tion number for ATNDIND=7199:
CHANGE-ACSU:ATNDNO=7199,STNOOOS=5555;

Caution: If you change the source group of a subscriber with AMO SDAT, the administered
source group related alternate routing informations may not be valid anymore for this sub-
scriber!

If the public network (Carrier) is checking the calling number, the new COT pa-
rameter R261 must be set on the CO / TIE trunk, to send the Redirecting num-
ber.
If an analoge Phonemail is used for OOS, the number is checked in AMO ZIEL.
If the number is a VMX (Type in AMO ZIEL) destination, the Redirecting num-
ber is send.
For using a digital Voicemail / Xpression the destination number of the Voice-
mail/Xpression has to be set in AMO ZIEL -> VMX, too. If the COT parameter
R261 is used on the Tie trunks instead of th VMX entry, there could be prob-
lems in a network.

2.2.1.2 Called subscriber is not reachable, because deactivated via AMO with
additional request for alternate routing
● What are the main goals?
Calling a subscriber specific individual alternate routing destination number (mobile phone
number)
Calling a general destination like analoge Phonemail, digital Voicemail/Xpression or atten-
dant.

● What is possible?
The alternate routing number can be designed to reach any other destination.
If the alternate routing destination number leads to a outgoing trunk access, only those
route elements will be used for alternate routing, that are defined as with " no internal re-
routing ".

27
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

analoge Phonemail
90417
7100

STN-A ATND= 99
OOS-NO=90147

7150 S2

Xpression
STN-B
90500
OOS-NO=90500

STN-C
7120
Deactivate-DSSU: STN-A
STN-D Deactivate-DSSU: STN-B
Deactivate-DSSU: STN-C
7121 Deactivate-DSSU: STN-C
Deactivate-BSSU:............
Source -Grp = 3 Deactivate-USSU:.............

ALT-NO = 99

● AMO usage
– Calls to a deactivated subscriber-A and subscriber_B should be alternate routed to the
analoge Phonemail respec. to the Xpression.
For routing type = OOS, you must define a subscriber individual alternate routing destina-
tion number for the subscriber_A and subscriber_B:
CHANGE-SDAT: STNO=7100,TYPE=DATA1,STNOOOS=90147;
CHANGE-SDAT: STNO=7150,TYPE=DATA1,STNOOOS=90500;

28
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

You must set a request for alternate routing, before deactivating the subscriber-A and
subscriber_B with AMO e.g. DSSU:
CHANGE-SDAT:STNO=7100,TYPE=DATA1,AMOALTRT=YES;
CHANGE-SDAT:STNO=7150,TYPE=DATA1,AMOALTRT=YES;

To send the Redirecting number to the Xpression and the Phonemail, the Xpression/Pho-
nemail number is to be set in AMO ZIEL:
ADD-ZIEL:TYPE=EVMACC,.....,MRCD=90500;
ADD-ZIEL:TYPE=EVMACC,.....,MRCD=90147;

– Calls to subscriber_C and subscriber_D of the related source group 3, should be al-
ternate routed to the attendant.
For the related source group, you can define a source group related complete alternate
routing destination number for routing type = OOS:
ADD-APRT:TYPE=ALTERR,SCRGRP=3,ALRTYPE=OOS,ALTRTNR=99;

You must set a request for alternate routing, before deactivating the subscriber_C and
subscriber_D with AMO e.g. DSSU:
CHANGE-SDAT:STNO=7120&&7121,TYPE=DATA1,AMOALTRT=YES;

If you set this request and no kind of alternate routing destination number was
administered before, the AMO SDAT will print out a hint-message.

If the public network (Carrier) is checking the calling number, the new COT pa-
rameter R261 must be set on the CO trunk, to send the Redirecting number.
If an analoge Phonemail is used for OOS, the number is checked in AMO ZIEL.
If the number is a VMX (Type in AMO ZIEL) destination, the Redirecting num-
ber is send.
For using a digital Voicemail / Xpression the destination number of the Voice-
mail/Xpression has to be set in AMO ZIEL -> VMX, too. If the COT parameter
R261 is used on the Tie trunks instead of th VMX entry, there could be prob-
lems in a network.

29
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

2.2.1.3 Called HFA IP phones (A,B) are not reachable, because of IP errors,
they moved their logon location from HiPath 4000 to HiPath 3000.

Scenario 1

CO Number:
+49-89-568
HiPath 4000 IP: 1.30.11.180 ISDN
STMI H G1 5 0 0
Moving by fault HiPath 3
000
IP: 1.40.41.180
IP
54711 Network

MOVING
4711
SUB-A
OOS-No =
00049895684711

54712
4712
MOVING

TLN-B
OOS-No =
00049895684712
or
Source-Grp = 2
ALT-No = 0004989568
with Extno= 4

30
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

● Device configuration:

HiPath 4000 HiPath 3000


number (HFA IP phone A): 54711 4711
number (HFA IP phone B): 54712 4712
station number length: 5 4

● What are the main goals?


The main goal is, to call the HiPath 4000 logged off HFA IP phone in its new logon switch
(Hipath 3000) via public trunk under its new or identical subscriber number.

● What is possible?
The alternate routing destination number can be designed as outgoing public trunk access
or outgoing tie trunk access followed by incoming trunk access to reach the Hipath 3000.
The alternate routing destination number can be designed as a subscriber individual alter-
nate routing number or as an incomplete source group related alternate routing number
(with supplementation request).
If the alternate routing destination number leads to a outgoing trunk access, only those
route elements will be used for alternate routing, that are defined as with " no internal re-
routing ".

Not allowed is a source group related complete alternate routing number, as it


is not possible, to reach individual subscribers in this way.
Not allowed are alternate routing numbers, that do not lead to a trunk access.

31
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

● AMO usage
– Calls to not reachable HFA IP phones, that have moved their logon location from
HiPath 4000 to HiPath 3000, should be routed to the new logon location via public net-
work. In HiPath 3000, the HFA IP phones have a different number scheme than in
HiPath 4000.
You must authorize those HFA IP phones, that can move their logon location from
HPath 4000 to HiPath 300:

CHANGE-SDAT:STNO=54711,TYPE=DATA1,MVHFAIP=YES;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,MVHFAIP=YES;
You must set the gateway_IP address(es) for the source group(s), the HFA IP phones are
members of. This is necessary to avoid loops within the HiPath 4000 and HiPath 3000 net-
work.
For example, it could be possible, that a HFA IP phone is already logged off in HiPath 4000
and not yet logged on in HiPath 3000. In this case, every switch tries to perform an alter-
nate routing to the other switch (ping/pong).
ADD-APRT:TYPE= ALTERR,SRCGRP=2,ALRTYPE=OOS,GWIPADR=1.30.11.180;
For type= OOS, you must define either subscriber individual alternate routing destination
numbers for every HFA IP phone (A,B) or a source group related incomplete alternate rout-
ing destination number for the source group(s), the HFA IP phones are members of.
A incomplete alternate routing destination number will be supplemented at time of usage
with the extension number of the called HFA IP phone and with the administered length
(parameter EXTNO). This makes it possible to reach individual subscribers in other switch-
es.
If you want to use only subscriber individual alternate routing destination numbers, you
have to administer a subscriber individual alternate number for both HFA IP phones with
outgoing trunk access to public network (004989), with incoming trunk access to reach the
HiPath 3000 (568) and the shortened part of the extension numbers (4711, 4712).
CHANGE-SDAT:STNO=54711,TYPE=DATA1,STNOOOS=0004989-568-4711;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,STNOOOS=0004989-568-4712;

32
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

If you want to use only source group related incomplete alternate routing destination num-
bers, you have to administer the source group related alternate destination number with
outgoing trunk access to public network (004989) and with incoming trunk access (568) to
reach the Hipath 3000.
Furthermore, you must set the supplementary length (parameter EXTNO) to the length of
the HFA IP phones number in the HiPath 3000, which is = 4.
ADD-APRT:TYPE=ALTERR,SRCGRP=2,ALRTYPE=OOS,ALTRTNR=0004989-568,EXTNO=4;

33
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

Scenario 1

CO Number:
+49-89-568
HiPath 4000 IP: 1.30.11.180 ISDN
STMI H G1 5 0 0
Moving by fault HiPath 3
000
IP: 1.40.41.180
IP
54711 Network

MOVING
954711
SUB-A
OOS-No =
0004989568954711

54712
954712
MOVING

TLN-B
OOS-No =
0004989568954712
or
Source-Grp = 2
ALT-No = 0049895689
with Extno= 5

● Device configuration:

HiPath 4000 HiPath 3000


number (HFA IP phone A): 54711 954711
number (HFA IP phone B): 54712 954712
station number length: 5 6

34
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

AMO usage
– Calls to not reachable HFA IP phone, that have moved their logon location from HiPath
4000 to HiPath 3000, should be routed to the new logon location via public network. In
HiPath 3000, the HFA IP phones have a different number scheme than in HiPath 4000.
You must authorize those HFA IP phones, that can move their logon location from
Hipath 4000 to HiPath 300:
CHANGE-SDAT:STNO=54711,TYPE=DATA1,MVHFAIP=YES;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,MVHFAIP=YES;
You must set the gateway_IP address(es) for the source group(s), the HFA IP phones are
members of. This is necessary to avoid loops within HiPath 4000 and HiPath 3000 network.
For example, it could be possible, that a HiPath 4000 logged off HFA IP phone is not yet
logged on in HiPath 3000 and every switch tries to perform an alternate routing to the other
switch (ping/pong).
ADD-APRT:TYP=ALTERR,SRCGRP=2,ALRTYPE=OOS,GWIPADR=1.30.11.180;
For type= OOS, you must define either subscriber individual alternate routing destination
numbers for every HFA IP phone (A,B) or a source group related incomplete alternate rout-
ing destination number for the source group(s), the HFA IP phones are members of.
A incomplete alternate routing destination number will be supplemented at time of usage
with the extension number of the called HFA IP phone and with the administered length
(parameter EXTNO). This makes it possible to reach individual subscribers in other switch-
es.
If you want to use only subscriber individual alternate routing destination numbers, you
have to administer a subscriber individual alternate number for both HFA IP phones with
outgoing trunk access to public network (004989), with incoming trunk access to reach the
HiPath 3000 (568), with a number prefix (9) and the extension numbers (54711,5 4712).
CHANGE-SDAT:STNO=54711,TYPE=DATA1,STNOOOS=<0004989-568-9-54711;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,STNOOOS=<0004989-568-9-54712;
If you want to use only source group related incomplete numbers, you have to administer
the source group related alternate destination number with outgoing trunk access to public
network (004989) and with incoming trunk access (568) to reach the HiPath 3000.
Furthermore, you must set the supplementary length (parameter EXTNO) to the length of
the HFA IP phones number in the HiPath 4000, which is 5:
ADD-APRT:TYP=ALTERR,SRCGRP=2,ALRTYPE=OOS,ALTRTNR=0004989-568-9,EXTNO=5;

35
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

2.2.1.4 Called subscribers (A,B) in its APs are in an APE situation to AP of the
calling device

Scenario 1:

APE situation
CO incoming:
4711 ISDN +49-89-723
AP 3700-IP

HiPath 4000

IP 4711
Network

4712
STN-A
OOS-NO =
001753333333
STN-B
ISDN
OOS-NO =
01753333333 001754444444
and
Source-Group = 17
ALT-NO for APE = 0004989723
01754444444 with EXTNO = 4

● Device configuration:
number (subscriber-A) = 4711
number (subscriber-B) = 4712
subscriber A,B in same source group 17

36
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

● What are the main goals?


The main goal is, to reach the subscribers, that are in APE situation to the calling device,
via public trunk loop in their own APs.
Another goal may be, to reach the subscriber via an individual phone number (Mobile).

● What is possible?
All other alternate routing destination numbers, that lead to a valid internal or external
phone number, are possible.
The alternate routing destination number can be designed as outgoing public trunk access
or tie trunk access followed by an incoming trunk access to reach an AP.
The alternate routing destination number can be designed as a subscriber individual alter-
nate routing number or as a source group related incomplete alternate routing number
(with supplementation request).
If the alternate routing destination number is designed as a source group related incom-
plete number, the supplementation can only be done with the identical subscribers exten-
sion number (parameter EXTNO = length of subscribers extension number).
If the alternate routing destination number leads to a outgoing trunk access, only those
route elements will be used for alternate routing, that are defined as with " no internal re-
routing ".

● AMO usage
– Calls subscribers A,B, that are in an APE situation to the calling device, should be rout-
ed to the called subscribers in its AP via public trunk loop.
In case of APE, in the AP of the calling devices, it can not be verified, whether the called
subscribers in their own AP are in a seizable situation or not. Therefore, it makes sense, to
alternate route the call to the originally called subscribers in their own APs via public trunk
loop. The incoming trunk at target AP, then can verify for sure the real state of the called
subscribers.
For type = APE, you have to administer either subscriber individual alternate routing num-
bers of type = APE for subscriber A and B or incomplete source group related alternate
routing numbers of type = APE for the source group(s), the subscriber A,B are members of.
If you are sure, you don’t need different alternate routing destinations for TYPE = OOS and
TYPE=APE, you also can administer the mentioned alternate routing destination numbers
for TYPE = OOS.

37
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

An incomplete alternate routing destination number will be supplemented at time of usage


with the extension number of the called subscriber A,B and with the administered length
(parameter EXTNO). This makes it possible to reach individual subscribers in other switch-
es.
If you use subscriber individual alternate routing destination numbers, you have to admin-
ister a subscriber individual alternate number for the subscribers A and B with outgoing
trunk access to public network and with the individual subscriber numbers of subscriber_A
and subscriber_B.
CHANGE-SDAT:STNO=4711,TYPE=DATA1,STNOOOS=<001753333333;
CHANGE-SDAT:STNO=4712,TYPE=DATA1,STNOOOS=<001754444444;
If you use only source group related incomplete alternate routing destination numbers, you
have to administer the source group related alternate destination number with outgoing
trunk access to public network and with incoming trunk access to reach the AP of the called
subscriber (A,B) in HiPath 4000.
Furthermore, you must set the supplementary length (parameter EXTNO) to the length of
the subscriber number in the HiPath 4000, which is = 4. In this case, you must not use a
different value for EXTNO than the length of the subscriber number of subscriber A or B.
ADD-APRT:TYPE=ALTERR,SRCGRP=17,ALRTYPE=APE,ALTRTNR=0004989-723,EXTNO=4;

With these settings in the Database, first the APE number is dialed by the host. If the dialing
of the APE number fails, the Mobile number (OOS) is dialed by the host.

38
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

Scenario 2:

APE situation
CO incoming:
4711 ISDN +49-89-723
AP 3700-IP

HiPath 4000

IP 4711
Network

4712
STN-A
APE-NO =
001711234567
STN-B
ISDN

ATND = 99 Source-Group = 18
ALT-NO for APE = 99
01711234567

● AMO usage
– Calls to not ready subscribers of source group 18 (STN-B), that are in an APE situation
to the calling device, should be routed to the attendant console. Calls to not ready sub-
scriber-A, of source group 18, that is in an APE situation to the calling device, should
be routed to a subscriber individual mobile phone number.
For type = APE, you must define a source group related complete alternate routing desti-
nation number for the source group = 18.
ADD-APRT:TYPE=ALTERR,SRCGRP=18,ALRTYPE=APE,ALTRTNR=99;
For type = APE and for subscriber-A, you must set the subscriber individual alternate rout-
ing number to the individual mobile phone number.
CHANGE-SDAT:STNO=4711,TYPE=DATA1,STNOAPE=001711234567;

39
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

If you are sure, you will not use different alternate routing destination numbers for OOS and
APE situations, it may be enough to define only alternate routing destination numbers for
the type = OOS.
ADD-APRT:TYPE=ALTERR,SRCGRP=18,ALRTYPE=OOS,ALTRTNR=99;
CHANGE-SDAT:STNO=4711,TYPE=DATA1,STNOOOS=001711234567;

40
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

2.3 Service information

2.3.1 Additional control mechanisms


To prevent loops or several alternate routes after the other, you can use 2 DARs,
“ALTRTOOS” for the “out of service” situation” and “ALTRTAPE” for the “Emergency” situation,
in AMO WABE. The number of the DAR must be used in AMO SDAT / APRT in the alternate
number.
For example:
AMO WABE: ALTRTOOS = 77
ALTRTAPE = 78

AMO SDAT: STNOOOS = 0089-723-77-.....


AMO APRT: ALRTYPE = OOS, ALTRTNR = 0089-723-77-.....

AMO SDAT: STNOAPE = 0089-723-78-.....


AMO APRT: ALRTYPE = APE, ALTRTNR = 0089-723-78-.......

2.3.2 General plausibility information


The AMO syntax checks cannot verify all implausible administered alternate routing informati-
ons.
The administrator therefore has to verify itself very careful, whether alternate routing destinati-
on numbers in networking leads to seizable destinations.
Even if implausible alternate routing data passes the amo syntax check, call processing will
prevent system confusion like loops in switch or networking.
Unusable alternate routing destination numbers will be indicated by advisory outputs at usage
time, if the related DIAGS switch is set.

2.3.3 Special restriction information


The AMO SDAT allows, to set the parameters MVHFAIP and AMOALTRT in parallel for HFA IP
phones. Specially for this type of subscriber, the combination of this 2 parameters does not
make sense, because a HFA IP phone, that is authorized for moving its logon location from
HiPath 4000 to HiPath 3000 in case of IP errors (MVHFAIP) must not request alternate routing,
if manuel deactivated by amo (AMOALTRT).
The parameter AMOALTRT only makes sense for those HFA IP phones, that are not authorized
for moving their logon location.
The related checks are performed only from call processing at time of execution.

41
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

2.3.4 Implausible conditions for supplementation


1. The administered source group related alternate routing destination number leads to
WABE result unequal trunk or PSM/PSE and the parameter EXTNO was set > 0.
– It makes no sense, to supplement a source group related alternate routing destination
number, that leads to a destination unequal trunk or PSM.
This will be rejected by syntax check of AMO APRT.
2. In case of routing type APE, the administered source group related alternate routing des-
tination number, leads to a public trunk access.
– If the value of parameter EXTNO is administered smaller than the length of the called
subscribers extension number, the related subscriber can not be reached.
The implausibility of the source group related alternate routing destination number for
this OOS scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
The result is, that this alternate routing destination number can not be used for routing
type APE.
– If the value of parameter EXTNO is administered bigger than the length of the called
subscriber extension number, it will be ignored.
In order to avoid wrong or misleading displays, the supplementation then will be done
only up to the real length of the called subscribers extension number.
– If the value of parameter EXTNO is administered bigger than the maximum length of
subscribers extension number, the command will be rejected by syntax check of AMO
APRT.
– If the administered source group related alternate routing destination number contains
only a trunk access into public network and the value of parameter EXTNO = 0, neither
an alternate destination nor the called subscriber in its AP can be reached.
A supplementation is necessary in this situation and a value of parameter EXTNO =
length of called subscriber must be set.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
The result is, that this alternate routing destination number can not be used for routing
type APE.
3. In case of alternate routing type = OOS because of device/board error or manual deacti-
vated by AMO, the administered source group related alternate routing destination number
leads to WABE result = trunk.

42
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

– If the value of parameter EXTNO is > 0, a supplementation with the called subscribers
extension number is requested. This makes no sense in general, as this subscriber is
in OOS state and cannot be seized successfully, even if doing a loop over public or tie
trunk.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
The result is, that this alternate routing destination number can not be used for this
routing scenario
4. In case of alternate routing type = APE or OOS because device/board error or deactivated
by AMO, the administered source group related alternate routing number contains the ac-
cess code for PSM/ PSE
● If the PSM/ PSE is designed with search length = 0, a supplementation is necessary
with the length of called subscribers number.
– If the administered parameter EXTNO is smaller than length of called subscriber, a
PSM search cannot be successful.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
The result is, that this alternate routing destination number can not be used for this
routing scenario
– If the administered parameter EXTNO is bigger than length of called subscriber, a
PSM search is possible.
The supplementation will done with the real length of the subscribers extension num-
ber.
– If the administered parameter EXTNO is bigger than maximum extension number
length, the command will be rejected by syntax check of AMO APRT
● If the PSM is designed with search length = x, a supplementation is necessary with
this length x
– If the administered parameter EXTNO is smaller than search length x, a PSM search
cannot be successful.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
– If the administered parameter EXTNO is bigger than search length x, a PSM search is
possible.

43
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

The supplementation will done up to the search length x.


5. In case of alternate routing type = OOS because HFA move logon from HiPath 4000 to Hi-
Path 3000, the administered source group related alternate routing destination number has
to be designed in that way, that is possible to reach the moved subscriber in its new switch
location via trunk access.
– If the administered parameter EXTNO = 0, the source group related alternate routing
destination number is designed as a complete number.
As it is not possible, to reach individual HFA IP phones with a unique unsupplemented
alternate routing destination number, this number cannot be used for this routing sce-
nario.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
– If the value of parameter EXTNO is bigger than the length of the called subscriber
number in HiPath 4000, the supplementation will be done up to the real extension
number length of the HFA IP phone in HiPath 4000.

2.3.5 Plausibility of alternate routing destination numbers


The AMOs SDAT, ACSU and APRT allow only numbers, that leads to a valid WABE result. Call
processing, when trying to use the administered alternate routing destination number does a
lot of additional plausibility checks in relation to the OOS scenario, the involved devices, the
READY state of the alternate destination etc.
The main goal of this additional checks are, to avoid loops in the network and to allow other
alternate destinations (call_forward), if the designed alternate routing numbers would lead to a
invalid or not seizable destination.
HFA IP phones with the authorization for moving their logon from HiPath 4000 to HiPath 3000
may be logged_off already in HiPath 4000 and not yet logged_on in HiPath 3000. In order to
avoid an alternate routing loop between this 2 locations, the IP address of the partner gateway
has to be administered for the related source group (of the HFA IP phones).
Call processing, when finding out, that the calling device transports the same IP address as
administered in the source group of the called HFA IP phone, avoids an alternate routing.

44
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

2.3.6 Output of Advisory messages


In order to be informed about not usable administered alternate routing data, you can request
a advisory printout with following AMO command.
CHA-DIAGS: PROGID=CC, COMP=CP2, S07=ON;
Whenever at time of execution, alternate routing on error is not possible because of invalid al-
ternate routing number administration, an advisory printout like following example will be prin-
ted out.
F4066 M4 N0093 NO ACT BPA CP ADVISORY 03-09-10 13:32:14
ALARM CLASS:CENTRAL:023
CC:15359 EC: 2017 UA:9740:4BB6 SP:C078:1136 LD:01-01-079-004
DT:6C ST:6C SN:B401 CEVT:EF CSEV: 0 CST: 0
FORMAT:24 MESSAGE-ID: 00060

45
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

1. 5. 9. 13. 17. 21. 25. 29.

1A8B2601 1D11003C 01040704 04030000 00040704 07040136 00005E13 2BC45E13

030F0000 00000000 00000000 00000000 00000000 00000000 00000F04 0F040F04

0F040F04 0F040F04 0F040F0 0F040F04 00000000 00040704 07040600 00000600

00000600 00000600 00000600 000F040F 040F040F 040F040F 040F040F 040F040F

040F040F 00000000 00000000 01

Byte 1: Diagnoseformat (1A)


Byte 2: Formatlänge (8B)
Byte 3-4: Calling Loden (3A00)
Byte 5: Calling Device Typ: (1D) = DB_CP_DEVTYP_DIGITE_SUB_A
Byte 6-7: Called Loden (3V00)
Byte 8: Called Device Typ (1C) = DB_CP_DEVTYP_DIGITE_MAIN
Byte 9: Called source group (01)
Byte 10: Called number length (04)

Byte 11-32: Called number (03 03 04 04......................)


Byte 33: Altern. route reason (02) 01: OOS AP-Emergency
02: OOS deactivated by AMO
03: OOS device / board error
04: OOS Move HFA logon
Byte 34: Altern. reject reason (04) 01: no gateway_IP address defined
02: defined gateway_IP = received
gateway_IP
03: no valid WABE result for
alt_rt_on_err
04: alt_rt_nr too short
05: alt_rt_nr equal to calling/ redir nr
06: supplementation of alt_rt_nr
impossible
07: alt_rt_nr is/becomes too long
08: alt_rt_nr same as redir_nr
09: length of supplementation invalid
0A: alt_rt_nr leads to not allowed dest
0B: alt_rt_nr not usable for PSM cond.
0C: alt_rt_nr not usable for PSE cond.
0D: alt_rt_nr not usable for PSE_CZ
condition
0E: destination for alt_rt_nr not free
0F: no loden found with alt_rt_nr

46
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

10: alt_rt_nr is equal to called or


calling number
11: suppl. not allowed for OOS
12: alt_rt_nr is source_group complete
13: no emergency nr defined for
HFA IP phone
14: alt_rt_nr defined but not usable
15: general implausibility in
alt_rt_on_err

Byte 35 length subscr indiv. alternate routing number fot type = APE
Byte 36 - 57 subscriber individual alternate routing number fot type = APE
Byte 58 length srcgrp related alternate routing number fot type = APE
Byte 59 - 80 source group related alternate routing number fot type = APE
Byte 81: number of supplementation digits for type = APE
Byte 82 - 85 gateway_IP-asdress (not used)
Byte 86 length subscr indiv. alternate routing number fot type = OOS
Byte 87 - 108 subscriber individual alternate routing number fot type = OOS
Byte 109 length srcgrp related alternate routing number fot type = OOS
Byte 110 - 131 source group related alternate routing number fot type = OOS
Byte 132 number of supplementation digits for type = OOS
Byte 133 - 136 gateway_IP address for HFA move logon
Byte 137 - 140 gateway_IP address in CPB
<

47
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

2.3.7 HiPath 4000 Assistant


An adaptation of A&S is necessary and requested and will be handed in later.

2.3.8 Realization via AMO: AMO or AMO Batch>

AMO feature relevant com- descriptions


mands
DIMSU ADD - TEST - DISP ● Define the maximum number of subscriber indi-
vidual alternate routing destination numbers
SDAT CHANGE - DEL - DISP● Administer the subscriber individual alternate
routing destination number for OOS
● Administer the subscriber individual alternate
routing destination number for APE
● Set the authorization to move the logon
location for a HPA IP phone
● Set the authorization for alternate routing on er-
ror, when deactivated by AMO
APRT ADD - CHANGE - DEL ● Administer the source group related alternate
- DISP routing destination number for OOS
● Administer the source group related alternate
routing number for APE
● Administer the source group related gateway_IP
address for OOS (move logon)
ACSU ADD - CHANGE - DEL ● Administer the subscriber individual alternate
- DISP routing destination for OOS
● Administer the subscriber individual alternate
routing destination number for APE
● Set the authorization for alternate routing on er-
ror, when deactivated by AMO

48
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens

2.4 Relevant AMOs

AMO Parameter Sprache/ Beschreibung/ Description


Language
DIMSU: ALTRUFNU d Anzahl der teilnehmerindividuellen alternativen Routing
USER Ziel-Nummern
ALTROUT e number of subscriber individual alternate routing desti-
nation numbers
SDAT UZHFAIP d Berechtigung fuer Logon in HiPath 3000
MVHFAIP e Authorization for move logon to HiPath 3000
AMOALTRT d Berechtigung fuer alternatives Routing, falls mittels
AMO deaktiviert
AMOALTRT e Authorization for alternate routing on error if manual
deactivated by AMO
TLNNUOOS d Teilnehmer-individuelle alternative Routing Nummer
fuer OOS
STNOOOS e Subscriber individual alternate routing number for OOS
TLNNUAPE d Teilnehmer-individuelle alternative Routing Nummer
fuer APE
STNOAPE e Subscriber individual alternate routing number for APE
ACSU AMOALTRT d Berechtigung fuer alternatives Routing, falls mittels
AMO deaktiviert
AMOALTRT e Authorization for alternate routing on error if manual
deactivated by AMO
TLNNUOOS d Teilnehmer individuelle alternative Routing Nummer fuer
OOS
STNOOOS e Subscriber individual alternate routing number for OOS
TLNNUAPE d Teilnehmer-individuelle alternative Rufnummer fuer APE
STNOAPE e Subscriber individual alternate routing number for OOS
APRT ALTERR d Typenausscheidung fuer den neuen Zweig Alternatives
Routen im Fehlerfall
ALTERR e Type definition for new brach = alternate routing on
error
ALRTYP d Typ des alternate Routings (OOS oder APE)
ALTRTYPE e Typ of alternate routing (OOS or APE)

49
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error

AMO Parameter Sprache/ Beschreibung/ Description


Language
ALTRTNR d Source Gruppe bezogene alternative Routing Nummber
fuer OOS oder APE
ALTRTNT e Source group related alternate routing number for OOS
or APE
ERWANZ d Erweiterungsangabe zur alternative Routing Nummer
fuer OOS oder APE
EXTNO e Supplementation information for alternate routing num-
ber for OOS or APE
GWIPADR d Gateway_IP Adresse fuer den Typ = OOS
GWIPADR e Gateway_IP address for type = OOS

50
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Smart Card Application Siemens

3 Smart Card application

3.1 Feature description


A Signature Module (Smart Card Reader) can be connected to an optiPoint 500/600 Telephone
(Up0E-interface) as well as an HFA IP Phone optiPoint 410/600.

S erver
optiP oint
optiPoint 500
500/600 (C A P /C A 4000)
S m art O ther
C ard S ignature optiP oint 410
optiPoint 400HFA
HFA S m artC ard Access
M odule optiPoint
optiP oint 600
600HFA
HFA H iP ath 4000 A p p licatio n S C A A A pplications
(S C )
A C L-C link

IS O
7816-4 C orN et-T S C orN et-T S A C L-C LA N

A Smart Card is plugged into the Signature module, authentication is then carried out in an
external server with the application "SmartCard Access Application SCAA".This is connected
to the HiPath 4000 via ACL-C and the CAP/CA4000 application.The results of the Authentifi-
cation by the application "SmartCard Access Application SCAA" can be used by other applica-
tions which can communicate with the application SCAA on the server..

The following functions are supported:


● Support of smart cards corresponding to the ISO ...7816, para1-4 standard.
● Support of the Local Security check procedure by which the user identifies themselves
with an ID via keyboard and display of the telephone as an owner of the card itself.
● The smart card provisions a connection via Hipath4000 between the signature mod-
ule and the application "Smart Card Access Application SCAA" on the server.This en-
ables the local security check procedure LSCP as well as the user prompts once the
application has seen the card
● The application mobile subscriber for activating the HiPath pin.

51
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Smart Card Application

3.2 User interface


The Smart Card can be inserted and removed in any state of the telephone(free, busy,etc).

The user interface to identify the user is controlled via SmartCard (Local Security check Pro-
cedure) by means of a Card ID which interfaces with the SmartCard Access Application SCAA
for the identification of the user.
The Smart Card Access Application SCAA takes control of the telephone display by placing it
into the Non-Voice condition and the Non-Voice LED is turned on.
The entered numbers of the Card ID are not seen on the display. The end of dial condition
( such as "#" or number of ID numbers) is configured in the Smart Card Access Application
SCAA .

After successful authentication from the Smart Card Access Application SCAA on the server
has been initiated,then the subscriber identified by means of the smart card has the feature
"mobile subscriber" activated. The input of the subscriber phone number which was neces-
sary with the chip card for Optiset E is not necessary with the SmartCard.
After inserting the card and successful activation of the feature "mobile user"the station has the
rights and special features of the smart card user (dial plan membership,traffic restriction
group,etc).This is also the case when a smart card is inserted while during a connection,with
another smart card or "Pin Manual".

3.3 Service information


Remark:
The description of the Smart Card Access Application SCAA is not part of this feature descrip-
tion.

Attention:
7 The implementation of the feature in the Hipath 4000 V2.0 is dependent on the
availability of the Application (SCAA) !

52
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Smart Card Application Siemens

3.4 AMO usage


1. The SmartCard feature is switched on in the system:
CHANGE-FEASU:TYPE=A,CM=SMARTCRD;
2. In the situation where the DVA-Application SCAA (here under applnu=61)already ex-
ists:
– ConfiguringSmartCard Access Application Link :
CHANGE-XAPPL:CTYPE=APPL,APPLNO=61,SECAPPL=111;

In the case where the DVA-Application SCAA does not exist:


– Configuring the DVA-Application and SmartCard Access Application Link
(The AMO CPTP is used to give the application a name with the parameter
APPLDP here for example. "SCAA") :
ADD-XAPPL:APPLNO=61,APPLDP="SCAA",NAME="APPLICATION 22",
SECAPPL=111;
Attention : With the Parameter SECAPPL no more than 20 SmartCard Access
Application Links can be configured!
3. In the case where the subscriber already exists:
– Additionally configuring the Signature Modules (SmartCard Reader)
for the subscriber:
CHANGE-SBCSU:STNO=3456,OPT=OPTI,IDCR=YES;
– Assign the SmartCard Access Application Linkto the subscriber:
CHANGE-SBCSU:STNO=3456,OPT=OPTI,SECAPPL=111;
– setting “Mobile User Activation via SCAA/AMU” for the subscriber:
CHANGE-SBCSU:STNO=3456,OPT=OPTI,APMOBUSR=YES;
– All parameters can be changed together with:
CHANGE-SBCSU:STNO=3456,OPT=OPTI,IDCR=YES,SECAPPL=111,
APMOBUSR=YES;

In the case where the subscriber does not yet exist:


ADD-SBCSU:STNO=3456,OPT=OPTI,etc.......IDCR=YES,
SECAPPL=111,APMOBUSR=YES;

53
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Smart Card Application

3.5 Relevant AMOs


● German and English examples of relevant AMOs and new parameters

AMO Parameter Sprache/ Beschreibung/ Description


Language
FEASU SMARTCRD D Leistungsmerkmal SmartCard im System freischalten
FEASU SMARTCRD E Activate SmartCard feature usage system wide
SBCSU SECAPPL D SmartCard Access Application Link zuweisen
SBCSU SECAPPL E Assign SmartCard Access Application Link
SBCSU APMOBUSR D Aktivierung Mobile User über SCAA/AMU
SBCSU APMOBUSR E Mobile User Activation via SCAA/AMU
XAPPL SECAPPL D SmartCard Access Application Link einrichten
XAPPL SECAPPL E Create SmartCard Access Application Link

54
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4 HG3550V2.0 WAML-replacement

4.1 General
The following scenarios give a summary of the application cases for the HG3550v2.0 WAML
Replacement .The exact description of the configuration of the second scenario (LAN-WAN) is
not part of this document ; this is covered by the configuration manual (HiPath 4000 Manager).
The HG3550 V2.0 is not intended to replace the WAML board.The purpose of the HG3550 V2.0
WAML is to make LAN Connectivity to UW, so that Remote Access(RAS) to the HiPath 4000
administration by means of HiPath assistant/manager is possible .(feature "Serviceability").
The LAN Connectivity is a feature which provides 2 Ethernet LAN interfaces and an ISDN con-
nection.
The Board required to this purpose is the HG3550 V2.0. With this board there is the possibilty
to attach an external LAN to the Hicom or HiPath 4000 and to make data transmission via the
ISDN network, from an arbitrary subscriber, into the Atlantic LAN (ATLLAN) and to the HiPath
assistant, provided that the required rights are existing.

To be able to use the LAN Connectivity, you must establish specific configuration data for the
WAML with WBM, after setting up the board with the appropriate AMOs. Only after this the
LAN Connectivity operational. On this occasion the configuration is not checked for consis-
tency with the topology of an existing network (e.g. IP-addresses).
An integrated LAN/ISDN Router function controls the transmission of the Data Packets
between the WAML Network interfaces.
These implementations are made possible:
● SCN-LAN

HiPath 4000
customer
H LAN
PSTN *) G
S0/S2 35
50
S0

H
U
B
ADP C Atlantic
LAN
e.g.. HTS

*) DIUS2 /.STMD

55
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

● LAN-WAN

Is only possible with the HiPath 4000 Manager !

customer HiPath 4000 HiPath 4000


LAN customer
H H
G *) PSTN *) G LAN
35 S0/S2 35
50 S0/S2 50

H H
U U
B B
e.g. DMS Atlantic C ADP ADP C Atlantic
LAN LAN

*) DIUS2/ STMD

In this feature usage document, only the scenario “SCN-LAN” is described.

56
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2 SCN-LAN
The PC with the phone numbers 7374 shall be allowed to dial in via an ISDN connection with
the phone number 80313 and access the UW7 ( IP address 192.0.2.5) via the Atlantic LAN. To
UW7 only PPTP connections are possible. The PPTP server in the UW7 (UBA) is configured
in this example in this way, that it allocates the IP-address 10.32.192.5 as virtual remote IP-
address.To this IP-address (10.32.192.5), UW7 uses the IP-address 10.32.254.193 (virtual lo-
cal) as gateway to the HG3550 V2.0. This is a fix address, set by the system. The allocation of
these IP addresses is fixed in the "VPN ADDRESS Space of HICOM 300 H for Hipath4000
V2.0". For this connection a CHAP authentification is required
(in this example; User: HG3550, password: 1234).

7374 HiPath 4000 V2.0


Atlantic

HG3550V2.0
ISDN 80313 LAN

Dial-up: 10.1.192.5
10.32.252.65
CLAN: 1.30.31.180
ATLAN: 192.0.2.4
Virtual: 10.32.254.193
CC local
ADP

UW7: 192.0.2.5
Virtual: 10.32.192.5
remote

57
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.1 Configuring the HiPath 4000 V2.0


The HG3550 V2.0 is reached via the phone number 80313 and is operated in Mixed mode. It
has the customer LAN IP address 1.30.31.180 and the Atlantic LAN IP address 192.0.2.4.

4.2.1.1 Adding the STMI2-IGW board and configuring the board data
● Assign Flexama Memory for STMI2-IGW configuration data with AMO DIMSU :
ADD-DIMSU:TYPE=SYSTEM,STMI2IGW=<number>;

● Adding the Board at LTU=2 and SLOT=25 (Q2316-X with 60 B-Channels, Q2316-X10 with
120 B-Channels):
ADD-BCSU:MTYPE=PER,LTU=2,SLOT=25,PARTNO="Q2316-X",FCTID=5;

● Adjust HG3550 V2.0 Board data:


ADD-STMIB:MTYPE=STMI2IGW,LTU=2,SLOT=25,CUSIP=1.30.31.180,
CUSPN=8000,SNETMASK=255.255.255.0;

CHANGE-STMIB:MTYPE=STMI2IGW,LTU=2,EBT=251,TYPE=IFDATA,ATLIP=192.0.2.4;

● To load the new board data to the board:


RESTART-BSSU:ADDRTYPE=PEN,LTU=2,SLOT=25;

4.2.1.2 Configuring the HG3550 V2.0 LAN circuit


● The COT to be used should be configured as follows:
ADD-COT:COTNO=XXX,PAR=ANS&CEBC&IEVT&BSHT&NTON&DFNN&NLRD&LWNC,
INFO="WAML-REPLACEMENT";

● The COP to be used should be configured as follows:


ADD-COP:COPNO=XXX,PAR=L3AR,TRK=TA,TOLL=TA,
INFO="WAML_REPLACEMENT";

● The COS to be used should be configuired as follows:


ADD-COSSU:NEWCOS=<number>,INFO="HG3550-2-LAN";
CHA-COSSU:TYPE=LCOSD,LCOSD=<number>,ALAUTH=1&&64;

58
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

● Adding a new Trunk Group (e.g.. 355):


ADD-BUEND:TGRP=355,NAME="HG3550-2-LAN",NO=30;

● Adding the Trunk HG3550 V2.0 LAN-Connectivity (for Q2316-X pen 1, for -X10 pen 3 is to
be used):
ADD-TDCSU:OPT=NEW,PEN=1-2-25-1,COTNO=<number>,COPNO=<number>,
COS=<number>,LCOSV=<number>,LCOSD=<number>,CCT="WAML_REP",ATNTYP=TIE,
PROTVAR=ECMAV2,SEGMENT=8,NNO=<numb.>,DEV=HG3550LA,TGRP=355,BCHAN=1&&30;

● Adding the call number (80313) for the HG3550 V2.0:


ADD-WABE:CD=80313,DAR=TIE,CHECK=N;

● Adding the Route (LRTE=355) for the STMI2-IGW trunk group:


ADD-RICHT:MODE=LRTENEW,LRTE=355,LSVC=ALL, NAME="WAML_REP",
TGRP=355,DNNO=e.g. 1-30-355;

● Adding outdial rule (e.g. ODR=355) :


ADD-LODR:ODR=355,INFO="WAML_REP",CMD=ECHO,FIELD=1;
ADD-LODR:ODR=355,CMD=NPI,NPI=UNKNOWN,TON=UNKNOWN;
ADD-LODR:ODR=355,CMD=END;

● Adding the LCR Route (LRTE=355):


ADD-LDAT:LROUTE=355,TGRP=355,ODR=355,LAUTH=e.g. 1;

● Adding the LCR dialing plan:


ADD-LDPLN:LCRCONF=LCRPATT,DIPLNUM=0,LDP=80313,LROUTE=355,LAUTH=e.g 1;

59
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

● Displaying the status of the circuit (possibly activate the circuit):

Please check after every Reset of the board (HG3550 V2.0) !

DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER3,LTG=1,LTU=2,SLOT=25;
RESTART-DSSU:TYPE=PEN,PEN1=1-2-25-1;

● Prevent new loading of the Loadware from harddisk, if the board is reset (faster loading):
CHANGE-FUNSU:PIT=FLASH,PARTNO="Q2316-X",FCTID=5,ACTION=RESET;

60
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.2 Configuring UBA in HiPath 4000 Assistant


● Setting the customer VPN Server address
Menu: Base Administration -> Unix Base Administration -> WAN Configuration

● The “PPP Links Details” message has to be filled out at the time, but the settings are not
used.

61
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

● Start the PPTP connection (in this example. Name: HG3550, Secret: 1234)

● Restart of the Unix Server.

62
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.3 Configuring the Gateway HG3550 V2.0

4.2.3.1 Installing XML30


● Execute msxml3ger.msi and follow the installation guide.

4.2.3.2 Establish connection to the HG3550 V2.0


Start the HiPath 4000 Assistant to get access to the Web Base Management (WBM) of the
board (a direct connection via an Internet Browser and IP address is no longer possible).
Menu: Expert Mode -> HG3550 v2 Manager

2nd. Connect with the WBM


1st. Search board(s) of the board

63
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

Enable write access

To change settings or to add new entries in the WBM - Explorer of the HG3550
V2.0, click with the right mouse button on the entry, which should be used.

64
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.3.3 Checking the LAN1 interface settings


The LAN1 interface is configured automatically by the AMO STMIB (only check the settings).
● Exlorer -> Network Interfaces -> LAN1 (LAN1)

65
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.3.4 Configuring the LAN 2 interface


The IP address of the Atlantic LAN is assigned automatically to the LAN2 interface by the AMO
STMIB. The other parameters have to be set as following; (CHAP Password: 1234):

66
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.3.5 Setting the WAML call number


The pc uses this number for dialing-up.
● Explorer -> Routing -> PSTN

67
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.3.6 Configuring PSTN Peer


The PC is configured in this way, that it expects an assignment of a IP address. The peer is
assigned the IP address 10.31.252.65 with the following configuration (CHAP Password: 1234).
● Explorer -> Routing -> PSTN -> PSTN Peers
Add new PSTN Peer (right mouse click):

68
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

69
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.3.7 Setting the calling number of the peer


The number 7374 will be transfered as Calling number. That number must be configured as
PSTN peer number, to identify the peer and its settings. In this case the authorization is set to
incoming and outgoing. It would also be possible to select only incoming, if a call only should
come from the SCN to the Atlantic LAN.
Add PSTN Peer Number (right mouse click):

70
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.3.8 Save board data


● Maintenance -> Configuration -> Load from Gateway

3rd Logoff

2nd Save configu-


ration on the PC

1st Save board data Load button

71
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.4 Configuration of the PC


The configuring of the PC is described by using a S0 card.
On the PC a “Dial-up Connection” is installed as following:

Normally an external number will be used (e.g. +49-89-722-80313) !

Installing: Start -> Settings -> Network and Dial-up Connections -> Make new
Connection

72
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

73
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

Select:
Properties

Select:
General

74
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

Select:
Networking

Select:
Settings

75
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

Select:
TCP/IP
Properties

Select:
IP address
Advanced...

76
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

Select:
General
Deactivate

77
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.5 Checking the VPN address and PPP1 settings


Use the HiPath 4000 Assistant Home Page to check the System Information.

Instruction: Home Page HiPath 4000 Assistant -> Clicking on “i” of “HiPath 4000 V2.0”

Select 16 (Network Interfaces):

78
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.6 Adding S0 subscriber

This step is only necessary in case of training !

ADD-SBCSU:STNO=7374,OPT=FBUS,CONN=DIR,PEN=1-2-37-5,DVCFIG=SET600&DTE,
COS1=131,COS2=131,LCOSV1=9,LCOSV2=1,LCOSD1=9,LCOSD2=1,DPLN=0,ITR=0,
SSTNO=N,COSX=0,SPDI=0,SPROT=SBDSS1,DPROT=SBDSS1,PERMACT=Y,INS=Y,
ALARMNO=11,SOPTIDX=10,DOPTIDX=10,EXTBUS=Y,RCBKB=N,RCBKNA=N,
CBKBMAX=5,HMUSIC=0;

79
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement

4.2.7 Starting the dial-up connection

Select:
Dial

4.2.8 Adding a “Route add” on the PC (DOS-cmd)


Is a LAN connection activated on the PC, the following Dos command is entered:

route add 10.32.192.5 10.32.252.65

80
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens

4.2.9 Getting access to the HiPath 4000 Assistant


Start the Internet Browser and enter the IP address 10.32.192.5:

81
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations

5 AMO authorizations in the HiPath 4000 V2.0

5.1 ADP

A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
ACMSM 4 4 4 4 4
AFR 5 5 5 0 0 0 5 5 5
ANUM 2 0 2
APC 0 0 2 2 2
APP 3
APS 0 0 2 2 2
ASPIK 2
ASSGN 2 0 2 0
ATCSM 2 2 2 0 2
AUTH 10 0 2
BACK 2 2 2 0 2 2 2 2 2
BCSM 2 2 0 2 2 2
CABA 2 2 2 2 2
CDBR 2 0 2 2
CDSM 0
CLIST 2
CMP 2
CMUID 5

82
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens

A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
CONSY 2 2 2 0 2 2
COPY 3
CPCI 2 0 2
CPSM 2 2 2 0 2
CPTP 2 2 0 2
CRON 5 5 5 0 2
DAGR 1 1 1 1 2 1
DASM 2 2
DATE 2 0
DAVF 1 1 2
DCSM 2 2 2
DDRSM 2 2 2 5
DDSM 0 2
DEBUG 3 3 3
DEFPP 2 2 2 0 2
DEFTM 2 2 2 0 2
DEL 3
DISPA 3 3
DLSM 2 2
DSSM 2 2 2 2
DPSM 2 2
DTSM 2 2 2 2

83
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations

A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
DUP 3
DVU 2 2 2
FAMOS 2 2 0 2 2 2
FAMUP 2 2 2 2 2 2 2 2 2 5
FBTID 2 2 2 2
0
FBTN 1 1 1 2
FEACG 4 4 0 2
FETA 1 1 1 2
FINF 2 2
FORM 3
FTBL 1 1 1 1 1
FTCSM 2 2 2 2 2
FTRNS 2 0 2
FUNCT 2 0 2
GEFE 2 0 2
GENDB 5
GETAB 1 1 0 2 1 1
GETPD 0
GEZAB 1 1 1 1 1 1 1
GEZU 2 2 2 0 2
GRA 2 2
GRZW 1 1 1 0 2

84
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens

A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
HISTA 2 2 2 0 0 2 2 2 2
INFO 2
INIT 3 0 3
JOB 5 0
KDEV 1 1 1 1 1 1
KDGZ 1 1 1 0 1
LCSM 2 2 2 0 2
LDB 3
LIST 2
LOGBK 5 5
LSSM 0 2 2 0
PASSW 5 5 5 5 2
PATCH 2 2 2 0 2 2 2 2
RCUT 1 1 1 1 2
REGEN 5
REN 3
REST 2 0 0 2
SAVCO 3
SAVE 3
SDSM 0
SELG 1 1 1 1 2 1
SELL 1 1 1 2

85
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations

A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
SELS 0 2 1 1 1 1
SIGNL 2 2 2 0 2 0 2 2 2 5
SONUS 2 0 2 2
SPES 2 2 0 2 2 2
SYNC 5 0 5 5
TABT 1 1 1 1 2
TCSM 2 2 2 0 2
TEST 0 0
TEXT 1 1 0 2
TINFO 2 0 2
TLZO 1 1 1 1 2
TRACA 2 2 2
TRACS 2 2 2
TTBL 1 1 1 1 2
UPDAT 2 0 2 2
USER 10 10 10 0 2 10 10 2
UW7 5 5 5
VADSM 2 0 2 2 2
VEGAS 2 2 0
XAPC 0 0 0 0

86
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens

5.2 CC
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
ACDGP 2 2 2 0 2
ACDRS 2 2 2 0 2
ACDRT 2 2 2 0 2 4 2 2
ACDSD 2 0 2
ACSU 2 2 2 0 2
ACTDA 2 2 0 2
AGENT 2 2 2 0 2
ANSU 2 0 2
APRT 2 2 2 2 2
AUN 2 2 2 0 2
AUTHO 0
BCSU 2 2 2 0 2
BDAT 2 2 2 0 2 2
BGDAT 2
BERUM 2 0
BERUZ 2 0 2
BGDAT 2
BPOOL 2 2 2 0 2
BSSU 2 2 2 2 5
BUEND 2 2 2 0 2
CDSU 0

87
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations

A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
CHESE 2 2 2 0 2
CODEW 5 3 5 5 3 5
COMGR 2 2 2 2 2
COP 2 2 2 0 2 2 5
COSSU 2 2 2 0 2
COT 2 2 2 0 2 2 5
CTIME 2 0 2
DBC 3 5 0 0 3
DBSUM 0
DCIC 2 2 2 0 2
DIAGS 2 0 5 5 5
DIDCR 2 2 2 0 2
DIMSU 4 0 2 4 0
DISPS 3 3 3 3
DNIT 2 2 2 0 2
DSSU 2 2 2 2 5 2 5
DTIM1 2 0 2
DTIM2 2 0 2
FEASU 4 0 2
FUNSU 2 0 2 2
GKREG 2 2 2 2 2
GKTOP 5 5 5 5 5

88
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens

A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
HFAB 2 2 0 2 2
HIDMP 2 2
HOTLN 2 2 2 0 2
KCSU 2 2 2 0 2
KNDEF 2 2 2 0 2
KNFOR 2 2 2 4 4 4
KNLCR 2 2 2 0 2
KNMAT 2 0 2
KNPRE 2 2 2 0 2
KNTOP 2 2 2 0 2 2
LANC 2 2 2 0 2 2 2
LAUTH 3 3 3 4 4
LDAT 2 2 2 0 2
LDPLN 2 2 2 0 2 2
LDSRT 2 2 2 0 2
LEMAN 2
LIN 2 2 2 2 2
LODR 2 2 0 2
LPROF 2 2 2 0 2
LRNGZ 2 2 2 0 2
LSCHD 2 0 2
LW 0

89
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations

A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
LWCMD 3
LWPAR 2 2 2 0 2 2
MFCTA 2 0 2 2
NAVAR 2 2 2 0 2
PERSI 1 1 1 1 1
PETRA 2 0 2 2
PRODE 2 0 2 2
PSTAT 2 2 2
PTIME 2 0 2 2
RCSU 2 2 2 0 2
REFTA 2 2 2 0 2 2
RICHT 2 2 2 0 2
RUFUM 2 2 0 2
SA 2 2 2 0 2
SBCSU 2 2 2 0 2
SCREN 2 2 2 0 2
SCSU 2 2 2 0 2
SDAT 2 0 2 5
SDSU 0
SIPCO 2 2 2 2 2
SSC 2 2 0 2
STMIB

90
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens

A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
SSCSU 2 2 2 0 2
STMIB 3
SXSU 2
SYNCA 2 2 2 0 2 2
TACSU 2 2 2 0 2 5 5 5
TAPRO 2 0 2 2
TDCSU 2 2 2 0 1 2 2
TGER 2 2 0 2
TREF 5 0 2 5 5
TSCSU 2 2 2 0 2
TSU 2 2 5
TWABE 2 2 0 2
UCSU 2 2 2 0 2
UPLOL 5
UPLO2 5
USSU 2 2
VADSU 2 2 2 0 2 2 2
VBZ 2 0 2
VBZA 2 0 2
VBZGR 2 2 0 2
VFGKZ 2 2 2 0 2
VFGR 2 2 2 0 2

91
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations

A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
VOICO 2 2 0 2 2 2
WABE 2 2 2 0 2
XAPPL 4 4 4 0 4
ZAND 2 0 2 5 5 5
ZANDE 2 0 2
ZAUSL 0
ZIEL 2 2 0 2
ZIELN 2 2 0 2
ZRNGZ 2 2 0 2

92
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens

5.3 Dropped AMOs

A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
BST 0 0 0
PSA 0 2 2 2
PSS 0 2 2 2

93
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens

6 Extended features and AMO changes in the


HiPath 4000 V2.0

6.1 AMOs
ACSU
– ACTYPE = AC4, ACW2Q und ACWMQ
– New ACWIN-Software for Windows XP: ACWIN 5.0 and ACWIN MQ 3.0
(DS-WIn 3.0 and BLF-Win 3.0 are necessary for ACWIN 5.0 and MQ 3.0.
ASC 3.0 (Hicom 300H) resp. ASC 4.0 (HiPath 4000) are necessary for ACWIN 5.0.
With ASC 5.0 both ACWIN variants can be used.)

BCSM
– DEACTIVATE-BCSM:UNIT=A1,SYSTEM=UNIX; -> Unix-Boot is blocked for the next
Unix-Restarts after the ADP-Data base is updated;
EXEC-UPDAT:UNIT=A1,SUSY=ALL;
– ACTIVATE-BCSM: UNIT=A1,SYSTEM=UNIX; -> Unix-Boot is started;
EXEC-UPDAT:UNIT=A1,SUSY=ALL;

BUEND
– Parameter RSV falls out.

94
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens

CPCI

– DISP-CPCI; Shows, which transfer mode are set for LAN in-
terfaces “Service” and “Atlantic” of the DSCXL
board, if the DSCXL board is used as ADP.
Additional is shown, if the switch is a DUAL or
MONO system, and if RTM modules are in-
stalled or not (important for generating a sys-
tem).
– CHA-CPCI: TYPE= Setting in which mode the LAN interfaces “Ser-
FRONTPAN vice” and “Atlantic” of the DSCXL board should
work, if the board is used as ADP or CC-AP.
(10 or 100 Mbits full or half duplex)
TYPE= Setting, if the switch is a MONO or DUAL sys-
SYSCONF tem, and if RTM modules are installed.
MONO Mono or Dual configuration (YES / NO)
RTM RTM board installed (YES / NO)

COP
– New parameter: LCOS -> Limitation of LAUTH to 32 for transfering;
– Parameters RES 162-171fall out;

COSSU
– The LCOSV- and LCOSD-classes can be increased up to 1000.
The highest number of the class depends on
AMO DIMSU:TYPE=USER,LCRCOS=xxxx;

95
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000

COT

– BKNA -> Activation disables feature “calling name delivery”


– BFSR -> Block forwarding switching after reject
– CDN -> Call deflection networkwide
– CFBN -> Call forward busy networkwide
– DTMF -> Inband dtmf when SETUP contains no classmarks
– IBBA -> Send digits via in-band dtmf before answer
– PGEP -> Partner node does not know HiPath GEP signalling
– SPCP -> Voice compression preferred

DIMSU
● USER
– LCRCOS Maximum number of LCOSV/LCOSD in AMO COSSU;
This is th highest number, which could be added in AMO COSSU; i.e. if 50 is set the
class 51 can not be added in AMO COSSU.
– ALTROUT Number of alternative numbers for subscribers, ATNDIND and AP-Emer-
gency, (OOS and APE);
– SLKTEXT Number of SLK keys with individual text;
– CALLOGS Number of devices with Self Labling feature (SLK);
– HOTDEST Number of Hotline destinations (up to 65535)
● NETWORK
– LDPLN1-8 LCR dialing plan 1-8; LDPLN1 for Standard LCR, LDPLN2-8 for Large
Gatekeeper;
– LDPLNC1-8 LCR dialing plan Cache; LWMC1 for Standard-LCR, LDPLNC2-8 for Lar-
ge Gatekeeper;
● SYSTEM
– STMIHFA2 Number of STMI2 boards (HG3530V2.0) for the feature HFA;
– STMI2IGW Number of STMI2 boards (HG3550V2.0) for the feature IP-Trunking V2;
– GWREG Number of internal and external Gateways (feature LEGK);
– CCAP Number of Emergency APs (feature APE);

96
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens

– EMGRP Number of Emergency AP groups (feature APE);


– SCTPATH Number of IP sectorpaths (feature Resource Manager);

FUNCT
– LOGBKOFF Prevents logbook entries (values 0-8):
– 0= none
– 1= DISPLAY-BUEND (cause: Traffic monitoring in the Assistant)
– 2= EXEC-UPLO/UPLO2
– 3= REGEN-CPTP
– 4= CHANGE-FUNCT;
2+3+4 are often used by UNIX.

HOTLN
– In branch: HOTDEST, destinations are increased to 2512;

LDAT
– Number of LRTEs is increased to 64000;

LDPLN
– Two new branches in parameter LCRCONF:
1. LCRPATT:
● DIPLNUM (0-2047)
In standard the DIPLNUM=0 is to be used;
DIPLNUM=0 is fixed and can not be changed or deleted;
Is used for 1:1 converting from HiPath 4000 V1.0 without the feature LEGK (Large
Enterprise Gatekeeper)

97
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000

2. LCRADM
● DIPLNUM (1-2047)
● LWMPOOL (1-8) -> DIMSU:NETWORK,LDPLN1-8
● DIALPLN (0-255)

LPROF
– Profile indexes are increased to 3000;

LSSM
– Switching the new LAN interfaces (LN=1-6,TYPE=LAN) at the cPCI-Shelf.

PATCH
– The noun REGENERATE for optional Patches is new;

RCSU
● New parameter branch for IP connections;
– CLASSMRK

RICHT
– Number of LRTEs increased to 64000;

SSC
– New parameter branch for IP connections with EXTANN:
● CLASSMRK

98
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens

TAPRO
– 256 key layouts;
– The TIME key shows during calls the time at the display for 10 seconds
(now usable for all opti);

VFGR
– Parameter CQMAXF falls out;

XAPPL
– The new parameter TSKA has to be set to YES in the application 92 (TSKA), if you
want to use the application in the HiPath 4000 Assistant V2.0;

ZAND
● ALLDATA
– DSSLT (Number of direct station select partners) increased to 70;
● ALLDATA2
– HOTELNUM Entering a number between 0 and 9 (number length of hotel stati-
ons);
– DISPREST Display name independent of supressed number;
– Parameter falls out: INDNADIS; the new parameter is DISPREST
● ALLDATA3
– CFNRDEST Call forward on no reply to the deactivated fixed call forward
destination (value USECFUF) (old CF concept). For the value
ONLYCFNR the special CF destinations (CFNR und CFB) are used
(new CF concept);
– EXANTRF external announcement after transfer;
– IPDAVCCF Voice Compression for IPDA connections in conference or
announcement situations;

99
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000

● OPTISET
– PUSECOK Pick up of second call enabled with OK key;
– CALLOG Supress the deletion of callog entries in the Service menu;
● CIT
– Parameter UMKOV falls out;

ZANDE

● ALLDATA
– SCALLOG Y -> Source number in callog;
After transfer the transfered subscriber (Subscriber_A)
is registered in the callog of the Subscriber_C;
N -> After transfer the transferring subscriber (Subscriber_B)
is registered in the callog of the Subscriber_C;
– VCANNCNF Y/N -> Voice Compression for conference and announcement
situations;
– H235SEC Y/N -> Activates / deactivates H.235 Security for STMI2IGW
boards;
– GATEKPR Y/N -> PBX with Large Enterprise Gatekeeper (LEGK);
– DECTPS Y/N -> Via this parameter the DECT Positioning System (laca-
ting of DECT Mobile phones) will be activated resp.
deactivated;
– NONPIIW Y/N -> For detailed describtion see ComWin300 Edit; (only
used in US);
– DAJB Y/N -> The configuring of the Jitter Buffer is not possible in the
WBM of a STMI2 board, if this parameter is set. The set-
ting in AMO STMIB branch DSP are used;
– NOVNIDCO Y/N -> Since HP4K V1.0 AMO KNMAT corrects the virtual
node ID to avoid dependences from node to node in dif-
ferent regions.If NOVNIDCO=YES is set, this behaviour
is disabled, what means, that the KNMAT modification
works like HP4K V1.0 before.
– IMPRPKZ Y/N -> If this parameter is set, both levels of one name key can
be chained for PKZ usage;

100
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens

– SILMON Y/N -> If this parameter is set, Silent Monitoring is only possible
for member of the ACD group of the monitorer. If this pa-
rameter is not set, there are no restrictions to any ACD
groups.

● OPTISET
– EDITDIAL Y/N Edited dialing for Up0E terminals (Deleting of single
numbers by using with the arrow key (positioning) and
the “-” key; For starting the call, use the OK key);
● MLPP Multi-level precedence and preemption service;
Special feature for the army (US);

6.2 CLIP for analog subscribers


● Requirement
The calling number and the name of the calling party should be displayed on analoge phones.
For that the ETSI Standard with FSK Modulation resp. DTMF signalling should be supported.
Also Visual Message Waiting Indication is required for FSK Modulation.

● AMO usage
In AMO ZAND the CLIP standard is set for the whole system. AMO BCSU and SCSU are used
for adding the SLMAC board and the analoge subcribers. AMO FEASU is used for activation
or deactivation of the CLIP analoge.

● Example for adding CLIP for analog subscribers


1. Adding the new board SLMAC:

ADD-BCSU:MTYPE=PER,LTU=XX,SLOT=XX,PARTNO="Q2191-C";

2. Adding of CLIP analoge subscribers with AMO SCSU (Without using parameter DHPAR):

ADD-SCSU:............................;

101
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000

3. Activation CLIP analoge standard:


CHANGE-ZAND:TYP=ALLDATA3,CLIPSTD=<CLIP standard>*;
*) CLIP standards: ETSIFSK (default), ETSIDTMF, BCMDMF, BCSDMF

4. Activation of the feature:


CHANGE-FEASU:TYPE=A,CM=CLIP&LEDSIGN;

● Generating VMWI
The feature is activated, when the SLMAC is used and the CLIP function for analoge phones
is activated.

● Restriction
The MWI/Mailbox signalling with fluorescent lamp (150 V) is not supported!

● Special cases
The feature CLIP for analoge phones is activated. The analoge phone has the MWI display
based on COMTEL. In this case the parameter DHPAR=LEDSIGN must be set in AMO SCSU
(SPEC= SUFDIAL or SOD).

6.3 Integrated features without any AMO control


● Chained features for digitale terminals (Multiple feature chaining in REPDIAL)(US);
e.g.: Pin activation code + PIN or LCR access code + dialing number;
● Pick up of a camped-on call via the Optiguide (US) (Pick-up camped-on call).
● Message Waiting LED (Mailbox-LED, Phone Mail/Xpression LED and Wait-Indicators for
analoge phones) is stored after a Soft-Restart and a common control switch over;
● Improved RMX Timer Handling;

102