Vous êtes sur la page 1sur 2

Energías Renovables

Dynamic power controller


CDP

Description
The CDP-0 / CDP-G range of dynamic power controllers shifts the operating point of the
solar field, enabling the inverter generation level to be regulated in accordance with the user's
consumption.

One of the main features of this series is that it can measure all the energy flows of the
installation:
—— Energy consumed by the user
—— Energy generated by the inverter
—— Energy consumed or injected into the mains
—— Energy from an auxiliary generating source.

The inverter power must be configured in these devices, and the CDP is capable, via a
communication channel, of adapting generation to energy consumption with the aim of
achieving zero injection to the electrical network. The CDP generates a database with all
information on the power and energy of every measurement point, including the regulation
percentage of the inverter, and also allows on-line monitoring via the internet. The CDP
has a built-in screen with two 20-digit lines, which displays all the electrical variables
measured by the unit. It also includes six indicator lights which allow the communication
status and alarm status to be checked in real time.

The unit also has features the following additional functions:


—— Control of a redundant network disconnection relay, used as an inverse current relay.
—— Control of up to three circuits in demand management mode, in the CDP-G model.

Application
The CDP is the ideal unit for managing photovoltaic installations for self-consumption without
mains injection.

Technical features
Power supply circuit Rated voltage 230 Vac
Tolerance 80%...115%
Frequency 50...60 Hz
Consumption 6 VA
Rated voltage 12 Vdc
Consumption 6W
Voltage measurement Measurement margin 10...300 Vac
circuit Frequency 50...60 Hz
Current measurement Nominal current .../250 mA
circuit Maximum current .../300 mA
Accuracy class Power 0.5%
Energy 1.0%
Relay outputs Number 4
Type Potential-free
Maximum operating current 6A
Communications User interface Ethernet
Communication with the inverter RS-232, RS-485, RS-422
Communication with other units RS-485

Mechanical features Dimensions 6 DIN modules


Material UL94 – V0 self-extinguishing plastic
Weight 250 gr
Environmental Operating temperature -25 ºC...+70 ºC
conditions Relative humidity 95% without condensation
Standards Safety of electrical measurement and control units IEC 61010-1:2010,
electromagnetic compatibility IEC 61000-6-2:2005, and IEC 61000-6-4:2011

1
Energías Renovables

Dynamic power controller


CDP

References
Type Code Description
CDP-0 E51001 Dynamic power controller, zero injection
CDP-G E52001 Dynamic power controller, zero injection and demand management

Dimensions

105 5 65
44

90 35,5 45 65

Web display Connections

CURRENT MEASURE
User
User L1
Grid L2
Inverter L3
Common Common
Single-phase Three-phase
connection connection

DC Power
Supply 12 Vd.c.

VOLTAGE MEASURE AC Power


User Supply 230 Va.c.
V1 User
Grid disconnection
V2 Grid
relay control
V3 Inverter
Neutral Neutral
Output for
Three-phase Single-phase load management
connection connection

Vous aimerez peut-être aussi