TKSA 80
Advanced laser shaft alignment tool
that increases alignment knowledge
Preparation Inspection
• The right tools and materials at the right place at the right time • Visual inspection
–– The system reminds users of the correct tools and materials to –– Inspection fields are provided for oil level, oil leakages, founda-
use, before carrying out the alignment job. tion bolt status and wear indications, etc.
• Horizontal and
vertical shaft
alignment
–– Measurements
are performed
at any of three
positions, with
a shaft rotation
of as little as
30 degrees.
2
• Machines train Reporting
–– Align three machines in a line (accommodates multiple • Results in graphical format
machine train alignment). –– The results are shown in graphical format and the file can be
easily copied and pasted into documents on a PC.
• The results show the machine conditions “as-found” and “as-cor-
rected”. Desired tolerances are also displayed.
• Energy efficiency
–– The system reports estimated extra energy consumption due
to misalignment.
Analyzing
• Alignment reports are recorded in the system, which helps users
periodically compare the alignment history and monitor the
machine’s health trend.
Standard programs
• Run-out check
–– The system reminds users to perform a simple measurement The following standard programs are available for the TKSA 80:
that discovers bent shafts.
• Horizontal • Vertical
Evaluation alignment alignment
• The system assists users to compare inspection results with the
information saved in the fast template to identify and prioritize
corrective actions.
• Soft foot by • Soft foot
laser manually
Correction
• Real-time correction • Visual • Alignment
–– The system displays the live actual value and direction for accu- inspection target
rate misalignment correction.
• Machine train
alignment
3
Technical data • Thermal sensors: ±2 °C
• Housing material: Chassis, aluminum sides, glass filled PBT
Complete System • Dimensions (height ™ width ™ depth): 96 ™ 83 ™ 36 mm
• Measure distance: Up to 10 m (3.8 ™ 3.3 ™ 1.4 in.)
(33.0 ft.) • Weight: 326 g (11.5 oz.)
• Relative humidity: 10 to 90% • Environment protection: IP 65
• Temperature range: –10 to • Ambient light protection: Optical filtering and ambient light signal
+50 °C (14 to 122 °F) rejection
• Weight (with case): 7.64 kg • Power supply: 2x AA alkaline batteries or rechargeable battery
(16.84 lb.)
Rod / fixing bar
Display unit • Length: 4 off 90 mm, 4 off 150 mm, can be screwed together to
• Display: Seven inch backlit color LCD, daylight viewable with touch increase length
screen and keypad
• Power: Rechargeable Li-ion battery and external power supply Standard shaft diameter
• Operating time on battery: Typical ten hours continuous operation • Up to 300 mm (11.8 in.)
• Storage memory: 64 MB
• Housing: PC / ABS plastic with integrated lockable stand
• Dimensions (height ™ width ™ depth): 276 ™ 160 ™ 53 mm Ordering information
(10.9 ™ 6.3 ™ 2.1 in.)
• Weight: 1 060 g (37.4 oz.) The TKSA 80 Shaft Alignment System consists of:
• Environment protection: IP 65
• Connectivity: Low-power, industrial wireless network, 802.15.4 • Display unit TKSA 80-DISPLAYUNIT, one (1) each
compliant • Measuring unit TKSA 60/80-HA and TKSA 60/80-HB, one (1)
–– USB: Host v1.1, device v1.1 each
• Drop test: 1,2 m (3.9 ft.) to MIL-STD-810F • Mechanical shaft fixtures, two (2) each
• Adjustable chains with tightening pin, two (2) each
Measuring units (A, B) • Rods, four (4) each
• Type of laser: Red diode laser –– 90 mm
• Laser wavelength: 635 nm –– 150 mm
• Laser safety class: Class II • Measuring tape, one (1) each
• Laser output power: <1 mW • Screw driver, one (1) each
• Measurement accuracy: • Tommy bar, one (1) each
Within 10 µm • USB cable, one (1) each
• Detector: Linear CCD with • Charger for display unit, one (1) each
length 36 mm (1.4 in.) • Quick start guide, one (1) each
• Accelerometer accuracy: • CD with instructions for use, one (1) each
±0,1° • Extension Chain, two (2) each
• Accelerometer resolution:
0,1° For a tailored solution for available applications, please contact your
local SKF Reliability Systems sales office.