DISEÑO DE CAIDAS

transicion de entrada
seccion de control

transicion de salida

muro vertical

colchon amortiguador

INGRESAR DATOS

CANAL AGUAS ARRIBA CANAL AGUAS ABAJO


DZ 1.000 m Q 0.310 m3/s
S 0.002 S 0.003
n1 0.015 n1 0.015
n2 0.015 n2 0.015
n3 0.015 n3 0.015
Z 1.000 Z 1.000
Q 0.310 m3/s

PROCEDIMIENTO
2/3
 n 
b= 0.828 y b= 0.8284271 y   Pixni 3 / 2 
b= 0.336 m b

 2* 1 z2  z  b= 0.3114886 m n   i 1 
n= 0.015 n= 0.015  P 
y  
 
 Q  A5 / 3  Q  A5 / 3
 1/ 2   ´2 / 3  1/ 2  
 S  nP S  nP
´2 / 3

6.9318 6.9402 5.6598 5.6555


y= 0.406 m y= 0.376 m
H= 0.72926 m H= 0.7292556 m

1. ANCHO DE CAIDA

q= 0.92
B= 0.34 m

2. ANCHO DE TRANSICION

a= 22.50 º
T1 = 1.15 m
T2 = 1.06 m
Lte = 0.10 m
Lte = 0.10 m

3. DIMENSIONAMIENTO DE LA CAIDA

q= 0.92 (m3/s)m
D= 0.09
LD = 2.22 m
yp = 0.58 m
y1 = 0.19 m
y2 = 0.86 m
L= 4.60 m
L= 4.60 m
Lest = 6.82 m
yc = 0.44 m

4. LONGITUD DE TRAMO DE CANAL RECTANGULAR

LC = 1.57 m

5. VENTILACIÓN BAJO LA LÁMINA VERTIENTE

qa = 0.05
Qa = 0.02 m3/s
LT = 2.00 m
f= 0.02
D= 0.038 m
= 0.02
= 0.06
A= 0.0011 A
1" = 0.0254 0.0005
0.5 " = 0.0127 0.0001
A= 0.00114

SE NECESITA 2 TUBOS DE 1 PULGADA O; 1 TUBO DE UNA PULGADA MAS CINCO DE MEDIA PULGADA

6. DIMENSIONAMIENTO DE ELEMENTOS COMPLEMENTARIOS

LONGITUD MINIMA DEL COLCHON L  Ld  2.55 y c

L 3.34938 m

UBICACIÓN DE LOS OBSTÁCULOS Lob  Ld  0.8 y c

Lob 2.57515 m

PROFUNDIDAD MÍNIMA DE LA CAPA DE AGUA


y 2  2.15 y c
Y2 0.9512 m

ALTURA OPTIMA DE LOS OBSTÁCULOS

hopobs= 0.35393 m hop.obs  0.8 y c

ANCHO DE LOS OBSTÁCULOS

aob= 0.17697 m
a ob  0.4 y c

ESPACIAMIENTO DE LOS OBSTÁCULOS

eob = 0.17697 m eob  0.4 yc

ALTURA ÓPTIMA DEL OBSTÁCULO FINAL

hop .obs . final  0.4 y c


hop.obs.final0.17697
= m