Lite
Engine Controller for Pumps
and Compressors
SW version 2.3.0
1 General information 2
2 Changes in the version 2.3.0 3
3 Changes in the version 2.2.0 7
4 Changes in the version 2.1.0 10
5 Changes in the version 2.0.0 14
6 Related information 15
7 Notes 16
IMPORTANT: This type of paragraph highlights a procedure, adjustment etc., which can cause a
damage or unproper function of the equipment if not performed correctly and may not be clear at
first sight.
Example: This type of paragraph contains information that is used to illustrate how a specific function
works.
AUT SpdReq
Setpoint group Regulator Related FW 2.3.0
Range [units] Reg Bias, LBi SpdUp/Dwn, CU AI1-CU AI9, AIO: AI1 - 4 [-]
Force value
Default value Reg Bias NO
Alternative config
Step -
Comm object 13068 Related applications N/A
Config level Standard
Setpoint visibility Always
Description
The setpoint is used for selecting what regulation will be used in AUTO mode in case automatic regulation is
disabled by LBI R Reg Disable. The options are:
Reg Bias – speed request will be set according to setpoint Reg Bias, this function was standard
functionality of R Reg disable LBI in previous FW versions.
LBI SpdUp/Dwn – it is possible to regulate speed manually by LBI Speed Up/Down even in Auto
mode.
CU AI1-CU AI9, AIO: AI1 - 4 – it is possible to regulate speed manually by analog inputs even in Auto
mode
The LBO Preheat is activated before engine start as same as LBO Prestart or Preglow, the time is
defined by new setpoints (PreheatTime1/2, PreheatTemp1/2) described below.
Activation of Preheat LBO has a variable activation time based on the measured temperature - it can
be activated either before or after Prestart LBO and is deactivated during cranking.
PreheatTemp2
Setpoint group Engine params Related FW 2.3.0
Range [units] PreheatTemp1 .. 600 [°C]
Force value
Default value 0 °C NO
Alternative config
Step -
Comm object 15986 Related applications N/A
Config level Standard
Setpoint visibility Always
Description
Defines the temperature, at which the LBO Preheat activates for the shortest time prior to engine start. See
description of LBO - Preheat (page 4)
PreheatTime2
Setpoint group Engine params Related FW 2.3.0
Range [units] 0 .. 600 [s]
Force value
Default value 0s NO
Alternative config
Step -
Comm object 15988 Related applications N/A
Config level Standard
Setpoint visibility Always
Description
Defines the longest time of the LBO Preheat activation prior to engine start reached when the measured
temperature is PreheatTemp2 or lower. See description of LBO - Preheat (page 4)
RA-FailDetect
Setpoint group Basic settings Related FW 2.3.0
Range [units] ENABLED / DISABLED
Force value
Default value ENABLED NO
Alternative config
Step N/A
Comm object 14599 Related applications N/A
Config level N/A
Setpoint visibility Always
Description
This setpoint is used to enable or disable fail detect function of RA15 module which enables or disables
alarm announcement in case RA15 is configured but not communicating.
Meaning of icons:
Icon Meaning Description
Exhaust System High Temperature Lamp Command Steady light - SPN 3698 = 001b
DEF tank has 0% measureable volume and machine Diagnostic Trouble Code:
performance is reduced SPN = 1761, FMI = 18
DEF system has lost its prime and machine performance Diagnostic Trouble Code:
is reduced. SPN = 1761, FMI = 01
Flash Malfunction Indicator Lamp (indicates that the Flash 1 Hz - SPN 3038 = 00b
active trouble code is emission-related) Flash 2 Hz - SPN 3038 = 01b
4.3 Repairs
Detection of stopped engine with active LBI Sprinkler
The engine with activated LBI Sprinkler correctly detects stopped engine.
Change value name of parameter Main Screen
The value SHOW AIN of parameter Main Screen (group Basic settings) was renamed to AIN6,7.
Archives (*.ail)
For ID-FLX-Lite
ID-FLX-Lite-2.3.0.ail