Vous êtes sur la page 1sur 1

Dr.

Fixit Pidicrete CF HC
High Range Water reducing Cum retarding admixture
PROVISIONAL DATA SHEET

Dr. Fixit Pidicrete CF HC is a superplasticising DOSAGE:


admixture design with specially formulated polymers to Dosage range of Dr. Fixit Pidicrete CF HC will be
produce homogeneous concrete, free from bleeding 200 ml to 600 ml per bag of cement.
and segregation. • Optimum dosage should be determined by
It also imparts the cohesiveness to concrete mix for doing site trial mixes. Dosage may go above

CONCRETE ADMIXTURES
easy pouring with better suface finish. maximum limit for High Performance Concrete
and shall be determined by site trial mix.
SPECIFICATION : IS: 9103-1999 and ASTM-C-494-
86, Type G COMPATIBILITY:
Dr. Fixit Pidicrete CF HC is compatible with
AREA OF APPLICATION: all types of cement e.g. OPC, PPC, PSC etc.
Pumpable Concrete Dr. Fixit Pidicrete CF HC is compatible with
Pavement Quality Concrete all air entraining agent which complies
wiith IS 9103-2003 and Integral water proofing
Ready mix concrete
compound which complies with IS 2645- 1978.
If other admixtures are to be used in concrete
FEATURES & BENEFITS: containing Dr. Fixit Pidicrete CF HC they must
Water reduction upto 20 % without effecting the be dispensed separately.
workability.
Helps in reducing cement content for a required SAFETY PRECAUTIONS :
strength by reducing w/c ratio. Dr. Fixit Pidicrete CF HC is a non-toxic and
inflammable. When in contact with the skin, it
should be washed with cold water.
Increases workability at a given w/c ratio, resulting
easy placing, and eliminates honeycombing.
High workability for longer periods to allow long TECHNICAL INFORMATION :
distance transport of concrete. Appearance : Dark Brown Liquid
Reduction in shrinkage cracks Sp.Gravity : 1.15 +/- 0.02
Chloride content : Nil
Less permeable and hence more durable concrete.
pH Value : 7 +/- 1

METHOD OF APPLICATION:
STORAGE : PIDICRETE CF 330
Concrete shall be mixed with 50-70% of the
• Keep the liquid above freezing temperature.
mixing water(based on mix design by weight).
• If the product has frozen, thaw it at room
The correct quantity of Dr. Fixit Pidicrete CF
temperature(25°C) and agitate to completely
151 should be measured with recommended
reconstitute it in the original form.
dispenser and should be added to the concrete with
remaining 30% mixing water and allow to mix it for • Store under cover ; protect from direct sunlight.
recommended mixing time. • Failure to comply with recommended storage
Dr. Fixit Pidicrete CF HC should not be added in dry condition may result in premature deterioration of
mixes under any circumstances the product and packaging.

PACKING: 250 & 265 kg,


Tanker supply in litres / kgs
Pidilite Industries Limited
Construction Chemicals Division expressed or implied guarantee / warranty as to the results obtained. The Company
does not assume any liability or any consequential damage for unsatisfactory
Ramkrishna Mandir Road Post Box No. 17411 results, arising from the use of our products.
Andheri (E) Mumbai 400059 INDIA
Tel +91-22-2835 7000 Fax +91-22-2835 7008
website www.doctor-fixit.com E-mail drfixit@pidilite.com
Disclaimer: The product information & application details given by the company
& its agents has been provided in good faith & meant to serve only as a general
guideline during usage. Users are advised to carry out tests & take trials to ensure
on the suitability of products meeting their requirement prior to full scale usage of
our products. Since the correct identification of the problems, quality of other
materials used and on-site workmanship are factors beyond our control, there are
no

Vous aimerez peut-être aussi