Laboratory Metallurgical Research & Testing Laboratory, Ichapur Road, Sealdanga,

Howrah, West Bengal


Location 1: Ichapur Road, Sealdanga, Howrah, West Bengal
Location 2: Balitikuri, Surkimill, Howrah, West Bengal
Accreditation Standard ISO/IEC 17025: 2005

Discipline Mechanical Testing Issue Date 19.11.2014


Certificate Number T-0295 Valid Until 18.11.2016
Last Amended on - Page 1 of 2
S.No. Product / Specific Test Performed Test Method Specification Range of Testing /
Material of Test against which tests are Limits of Detection
performed

Location 1
I. MECHANICAL PROPERTIES OF MATERIALS
1. Ferrous, Non- Tensile Strength IS 1608: 2005 (RA 2010) (140 to 1600) N/mm2
Ferrous, Rolled BS EN 10002-1-2001
Forged, Cast Yield stress (170 to 1200) N/mm2
Materials &
Fabricated 0.5 % Proof Stress (150 to 1000) N/mm2
Components.
0.2 % Proof Stress (140 to 1000) N/mm2

% Elongation 1 % to 75 %

% Reduction of area 2 % to 80 %

Bend test IS 1599 : 2012 Qualitative


(Mandrel Diameter:
1,2,4,6,8,10,12,15,16,18,
20,21,22,24,27,28,30,32,
33,36,39,40,42,44,45,48,
50,52,54,56,60,66,70,72,
75,80,84,90 & 100) mm
Brinell hardness test IS 1500 (Part 1): 2005 (RA 2013) (100 to 600) HBW
10/3000
Rockwell hardness test (A,B,C) IS 1586 : 2003 (RA 2012) (45 to 88) HRA
(20 to 100) HRB
(20 to 70) HRC

Location 1
2. Tubular Products Drift expansion test IS 2335: 2005 Qualitative
(Outside Diameter:

N. Venkateswaran Rahul Jain


Program Manager
Laboratory Metallurgical Research & Testing Laboratory, Ichapur Road, Sealdanga,
Howrah, West Bengal
Location 1: Ichapur Road, Sealdanga, Howrah, West Bengal
Location 2: Balitikuri, Surkimill, Howrah, West Bengal
Accreditation Standard ISO/IEC 17025: 2005

Discipline Mechanical Testing Issue Date 19.11.2014


Certificate Number T-0295 Valid Until 18.11.2016
Last Amended on - Page 2 of 2
S.No. Product / Specific Test Performed Test Method Specification Range of Testing /
Material of Test against which tests are Limits of Detection
performed

10 mm to 150 mm)

Flattening test IS 2328: 2005 Qualitative


(Outside Diameter:
10 mm to 6000 mm)

3. Fasteners Proof load test IS 1367 (Part 3): 2002 (RA 2007) 8 mm to 36 mm
(Bolt & Nut) IS 1367 (Part 6): 1994 (RA 2010)

4. Fasteners (Bolt) Axial Tensile test IS 1367 (Part 3): 2002 (RA 2007) 8 mm to 36 mm
Wedge Tensile test IS 1608: 2005 (RA 2010) 8 mm to 36 mm

5. Rivet Shear test IS 10102: 1982 (RA 2005) 6 mm to 30 mm

Head Soundness test IS 10102: 1982 (RA 2005) 6 mm to 42 mm