Vous êtes sur la page 1sur 4

ANSWER KEYS:

APPLY SETBACKS BASED


ON RULE 8, TABLE VIII.3,
PG.138. SINCE IT IS
GIVEN THAT THE ROAD-
RIGHT-OF-WAY IS 25
METERS. THEREFORE, ACTUAL PSO BY
THE SETBACKS ARE: SETBACKS IS
13,104 SQ.M.
FRONT: 6.00 M

REAR: 3.00 M

SIDES: 3.00 M
1. C UTS pg. 59
2. D Division E-1, pg.59
3. AMBF = 7,500 SQ. M. (50% OF TLA = .50 x 15,000)
4. PSO = 50%
*BY ACTUAL SETBACKS PSO = AMBF/TLA
= 13,104 SQ. M / 15,000 SQ. M
= 0.8736 x 100%
PSO = 87%
*BY RULE VII.1, pg. 88 Under Character of Use = Transportation
Assume it is Regular / Inside Lot since airport is a stand-alone development and
so without firewalls. It gives a 50% of TLA.
*BY RULE VIII.1, pg. 132 Under the UTS = Maximum Allowable PSO without firewall
PSO = 50%
Therefore; PSO = 50% is the most stringent in the 3.
5. TOSL = 7,500 SQ. M
On pg. 132 under UTS it stated that TOSL is 50e (w/o firewall) so, 50% of TLA = 7,500 sq. m
6. MACA = 13,500 SQ. M, pg. 132
*Formula: MACA = PSO + ISA
= (50% + 40% of TLA = 90%)
= 90% of 15,000 SQ. M
MACA = 13,500 SQ. M
7. GFA = 45,000 SQ. M, pg. 120
*Formula: GFA = TLA x FLAR
= 15,000 x 3 (in FLAR use maximum)
GFA = 45,000 SQ. M
8. TGFA = 67,500 SQ. M, pg.121 (table VIII.G.2)
-There are 3 option in computing for the TGFA
a. by actual space program (add all the given area in square meters to get the total gross floor
area.
b. by BHL x TLA (if given the TLA and BHL and there no other given because sometimes the
AMBF is also the GFA if not specified by space)
c. by GFA x multiplier (Given the computed GFA + non GFA areas)
*Formula: TGFA = GFA x MULTIPLIER
= 45,000 x 1.50 (multiplier to convert GFA to TGFA)
TGFA = 67,500 SQ. M
9. B 15 M
10. B 90 Parking slots, pg. 107
Under Division E-1 = UTS (1 car slot for every 500 SQ. M of Gross Floor Area)
= GFA (45,000 sq.m) ÷ 500 sq.m (for 1 car slot)
= 90 car slots
11. A 1 with 2 queuing buses, pg.107 under UTS
12. D 3.6 m x 12 m, pg. 100
13. B 150psf
14. B 2 *90 parking slots ÷ 50 of (1 car for every 50) = 1.8 or 2
15. C 3.7m x 5m
16. D 10m, the nearest
17. C on the west side of the building
18. B Signage and Flagpole (it is the most important in all Public Spaces or building use)
19. C with vertical sun shading devices
20. Rentable Spaces – 70% of GFA = 31,500 sq.m
21. Non Rentable Spaces – 30% of GFA = 13,500 sq.m
22. D 4
23. B 60, pg. 97
24. C 1:7, pg. 97
25. C 315m, pg. 97
26. Hfd
27. Ukk
28. Rtr
29. Tyy
30. B 3.5m
31. D 3.5m
32. A China Granite
33. D Double Glazing of Windows
34. B Deplaning of Curb
35. C 45cm
36. B Yellow

Vous aimerez peut-être aussi